TENANCY 2 FOOD OUTLET TENANCY 1 SERVICE STATION SERVICES FUEL DISPENSING FORECOURT ENTRY ENTRY D/THRU ENTRY D/THRU EXIT MIDDLE ROAD C RE ST ROA D PROPOSED ENTRY/EXIT (LEFT IN / LEFT OUT ONLY) PROPOSED ENTRY/EXIT NEIGHBOURING SITE NEIGHBOURING SITE SERVICES 5400 906 0 19560 5400 4200 D/THRU ORDER POINT FUEL VENTS 150 0 D/THRU PAY POINT D/THRU PAY POINT AIR / WATER 1 7 8 11 12 26 SITE BOUNDARY SITE BOUN DARY REFUSE ENCLOSURE PYLON SIGNAGE BIO RETENTION DRIVE THRU QUEUEING FUEL FILL POINTS 4500 7200 7200 10000 4500 4 95 5 13225 U/GROUND FUEL STORAGE TANKS 10000 29160 18200 3190 2020 6875 5400 2595 10115 TYP 2600 13875 PYLON SIGNAGE NEW 1500 WIDE FOOTPATH NEW ENTRY FOOTPATH SPEED HUMP SPEED HUMP PAINTED CHEVRON LINEMARKING ACOUSTIC/AWNING STRUCTURE TO FULL EXTENT OF CAR PARKING BAYS. REFER ACOUSTIC REPORT DELIVERY/REFUSE COLLECTION BAY LINE OF CANOPY OVER LINE OF CANOPY OVER 10625 4150 650 3200 1500 7200 1500 3200 ACOUSTIC BARRIER ACOUSTIC BARRIER ACOUSTIC BARRIER TO D/THRU. REFER ACOUSTIC REPORT PAINTED CHEVRON LINEMARKING RPD LOT 1 ON SP107492 PARISH OF MITCHELL COUNTY OF STANLEY LOT AREA - 4,238m² DEVELOPMENT ASSESSMENT • TENANCY 1 - SERVICE STATION - 228m² • TENANCY 2 - FOOD & DRINK OUTLET - 162m² • TOTAL CAR PARKING - 26 • CAR REFUELLING POSITIONS - 8 • D/THRU QUEUE CAPACITY - 12 BUILDING AREAS - GFA • CAR DISPENSING FORECOURT - 325m² (UNENCLOSED BUILDING FOOTPRINT) • REFUSE & SHARED SERVICES - 80m² MISCELANEOUS STRUCTURES CAR PARKING Revision and approvals This drawing is the c copyright & property of VERVE BUILDING DESIGN and must not be used or duplicated without authorisation. Do not scale this drawing. Check all dimensions on site prior commencement of works c 2011 copyright, all rights reserved. f a s t f o o d r e s t a u r a n t d e s i g n t r a v e l c e n t r e / s e r v i c e s t a t i o ns p r o j e c t c o n c e p t t o c o m p l e t i o n c o m m e r c i a l / i n d u s t r i a l / r e t a i l Project Description Drawing Title Job Number - Drawing Number Revision i m a g i n e BUILDING DESIGNERS LICENCE No. 1002212 OFFICE 1, LEVEL 1, 318 JUNCTION RD, CLAYFIELD 4011 PH. (07) 3857 0942 E: [email protected]CONSULTING ENGINEER THIS DRAWING IS NOT DA ISSUE FOR CONSTRUCTION Scale @A1 Drawn Date Approved By ALL SCHEDULES SHOULD BE CHECKED WITH THE REMAINDER OF THE DRAWING SET. SCHEDULED RATES AND AREAS ARE INTENDED FOR ASSISTANCE ONLY. NO RESPONSIBILITY IS TAKEN FOR THE ACCURACY OF QUANTITIES. ANY DISCREPANCIES IN SCHEDULES SHOULD BE IDENTIFIED TO THE AUTHOR NOTED. ALL AREAS ARE GROSS AREAS, UNLESS NOTED OTHERWISE VERVE SCHEDULES DISCLAIMER: 1. 2. 3. 4. c r e a t e d e l i v e r D As indicated DA01 PROPOSED MIXED USE DEVELOPMENT 356 MIDDLE ROAD, GREENBANK PROPOSED SITE PLAN 16102 JG APR - 2017 GN TRAFFIC SIGNAGE. GIVE WAY & NO RIGHT TURN. Rev Date Drn Description Appr A 19.05.17 JG ISSUE FOR D.A. B 31.07.2017 CWS REVISED ISSUE FOR D.A. - NEW PEDESTRIAN FOOTPATHS, COVERED & RELOCATED CARPARKING, FULL SITE SHOWN, ACOUSTIC PANELS AND FENCING PER ACOUSTIC REPORT C 04.08.2017 CWS RESPONSE TO COUNCIL IR D 18.10.2017 CWS RESPONSE TO COUNCIL IR
6
Embed
DA ISSUE THIS DRAWING IS NOT - Roubaix Properties · as indicated da01 proposed mixed use development 356 middle road, greenbank proposed site plan jg 16102 apr - 2017 gn traffic
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
TENANCY 2 FOODOUTLET
TENANCY 1SERVICE STATION
SERVICES
FUEL DISPENSING FORECOURT
ENTRY ENTRY
D/THRU ENTRYD/THRU
EXIT
MIDD
LE R
OAD
CREST ROAD
PROPOSED ENTRY/EXIT (LEFT IN / LEFT OUT ONLY)
PROPOSED ENTRY/EXIT
NEIGHBOURING SITE
NEIGHBOURING SITE
SERVICES
5400
9060
1956
054
0042
00
D/THRU ORDER POINT
FUEL VENTS
1500
D/THRU PAY POINT
D/THRU PAY POINT
AIR / WATER
1 7 8 11
12 26
SITE
BOU
NDAR
Y
SITE
BOU
NDAR
Y
REFUSE ENCLOSURE
PYLON SIGNAGE
BIORETENTION
DRIVE
THRU
QUE
UEING
FUEL FILL POINTS
4500 7200 7200 10000 45004955
13225
U/GROUND FUEL STORAGE TANKS
1000
029
160
18200
3190
2020
6875
5400
2595
10115
TYP
2600
13875
PYLON SIGNAGE
NEW 1500 WIDE FOOTPATH
NEW ENTRY FOOTPATH
SPEED HUMP
SPEED HUMP
PAINTED CHEVRON LINEMARKING
ACOUSTIC/AWNING STRUCTURE TO FULL EXTENT OF CAR PARKING BAYS. REFER ACOUSTIC REPORT
DELIVERY/REFUSE COLLECTION BAY
LINE OF CANOPY OVER
LINE OF CANOPY OVER
1062
5
4150 650 3200 1500 7200 1500
3200
ACOU
STIC B
ARRIER
ACOUSTIC BARRIER
ACOUSTIC BARRIER TO D/THRU. REFER ACOUSTIC REPORT
PAINTED CHEVRON LINEMARKING
RPD LOT 1 ON SP107492PARISH OF MITCHELLCOUNTY OF STANLEY
LOT AREA - 4,238m²
DEVELOPMENT ASSESSMENT
• TENANCY 1 - SERVICE STATION - 228m²• TENANCY 2 - FOOD & DRINK OUTLET - 162m²
• TOTAL CAR PARKING - 26• CAR REFUELLING POSITIONS - 8• D/THRU QUEUE CAPACITY - 12
BUILDING AREAS - GFA
• CAR DISPENSING FORECOURT - 325m²(UNENCLOSED BUILDING FOOTPRINT)
• REFUSE & SHARED SERVICES - 80m²
MISCELANEOUS STRUCTURES
CAR PARKING
Revision and approvals
This drawing is the c copyright & property of VERVE BUILDING DESIGN and must not be used or duplicated without authorisation.
Do not scale this drawing.
Check all dimensions on site prior commencement of works
c 2011 copyright, all rights reserved.
f a s t f o o d r e s t a u r a n t d e s i g n
t r a v e l c e n t r e / s e r v i c e s t a t i o ns
p r o j e c t c o n c e p t t o c o m p l e t i o n
c o m m e r c i a l / i n d u s t r i a l / r e t a i lProject Description Drawing Title
ALL SCHEDULES SHOULD BE CHECKED WITH THE REMAINDER OF THE DRAWING SET.SCHEDULED RATES AND AREAS ARE INTENDED FOR ASSISTANCE ONLY. NO RESPONSIBILITY IS TAKEN FOR THE ACCURACY OF QUANTITIES.ANY DISCREPANCIES IN SCHEDULES SHOULD BE IDENTIFIED TO THE AUTHOR NOTED.ALL AREAS ARE GROSS AREAS, UNLESS NOTED OTHERWISE
VERVE SCHEDULES DISCLAIMER:1.
2.
3.
4. c r e a t e d e l i v e r DAs indicated
DA01
PROPOSED MIXED USE DEVELOPMENT
356 MIDDLE ROAD, GREENBANK
PROPOSED SITE PLAN
16102JG
APR - 2017
GN
TRAFFIC SIGNAGE.GIVE WAY &
NO RIGHT TURN.
Rev Date Drn Description Appr
A 19.05.17 JG ISSUE FOR D.A.
B 31.07.2017 CWS REVISED ISSUE FOR D.A. - NEW PEDESTRIANFOOTPATHS, COVERED & RELOCATED CARPARKING, FULLSITE SHOWN, ACOUSTIC PANELS AND FENCING PERACOUSTIC REPORT
C 04.08.2017 CWS RESPONSE TO COUNCIL IR
D 18.10.2017 CWS RESPONSE TO COUNCIL IR
shorts
Line
shorts
Callout
Acoustic/awning structure to full extent of car parking bays as indicated in red, and in accordance with the recommendations in the acoustic report
KinselS
Approved plan of development
TENANCY 2 FOOD
OUTLET
TENANCY 1
SERVICE STATION
SERVICES
REFUSE
ENCLOSURE
FUEL DISPENSING FORECOURT
LINE OF CANOPY OVER
LINE OF CANOPY OVER
LINE OF AWNING OVER
LINE OF AWNING OVERLINE OF AWNING OVER
LINE OF AWNING OVER
OFFICE STORE
PWD
DRIVE THRU
PICKUP POINT
DRIVE THRU
PAY POINT
DRIVE THRU
ORDER POINT
PYLON SIGN
PYLON SIGN
13570 21500 4325 13875
1405
054
00
AMB
CLR
COLD ROOMFRZSTORE
CONSOLE
SITE BOUNDARY
SITE
BOU
NDARY
SITE
BOUNDARY
VARIED HEIGHT ACOUSTIC
BARRIER PANELLING
VARIED HEIGHT ACOUSTIC
BARRIER PANELLING
CLEAR PERSPEX PANELS TO
D/THRU ACOUSTIC BARRIER
CLEAR PERSPEX PANELS TO
D/THRU ACOUSTIC BARRIER
SPEED HUMP
SPEED HUMP
ACO
USTIC B
ARRIER
AIR/
WATER
Revision and approvals
This drawing is the c copyright & property of VERVE BUILDING DESIGN and must not be used or duplicated without authorisation.
Do not scale this drawing.
Check all dimensions on site prior commencement of works
c 2011 copyright, all rights reserved.
f a s t f o o d r e s t a u r a n t d e s i g n
t r a v e l c e n t r e / s e r v i c e s t a t i o ns
p r o j e c t c o n c e p t t o c o m p l e t i o n
c o m m e r c i a l / i n d u s t r i a l / r e t a i lProject Description Drawing Title