EVALUATION REPORT Cooler Master MPZ-C002-AFBAT EFFICIENCY AND NOISE LEVEL CERTIFICATIONS www.cybenetics.com CYBENETICS OFFERS THE ETA AND LAMBDA VOLUNTARY CERTIFICATION PROGRAMS, THROUGH WHICH THE EFFICIENT AND SILENT POWER SUPPLIES ARE PROMOTED [email protected]4004 MESA GEITONIA, LIMASSOL, CYPRUS All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case PAGE 1/9 DUT INFORMATION Brand Cooler Master Manufacturer (OEM) Murata Series MasterWatt Maker MIJ Model Number MPZ-C002-AFBAT Serial Number MPZC002AFBAT1164600010 DUT Notes Low PF and 5VSB Efficiency DUT SPECIFICATIONS Rated Voltage (Vrms) 100-240 Rated Current (Arms) 15-6 Rated Frequency (Hz) 50-60 Rated Power (W) 1200 Type ATX12V Cooling 135mm LDB Fan (Silencio FP) Semi-Passive Operation ✓ Cable Design Fully Modular POWER SPECIFICATIONS Rail 3.3V 5V 12V 5VSB -12V Max. Power Amps 25 25 100 3.5 0.5 Watts 130 1200 17.5 6 Total Max. Power (W) 1200 CABLES AND CONNECTORS Modular Cables Description Cable Count Connector Count (Total) Gauge ATX connector 20+4 pin (700mm) 1 1 18-22AWG 4+4 pin EPS12V (700mm) / 4+4 pin EPS12V (800mm) 2 2 16AWG 6+2 pin PCIe (760mm) 4 4 16AWG 6+2 pin PCIe (610mm+120mm) 4 8 16-18AWG SATA (450mm+110mm+110mm+110mm) 2 8 18AWG SATA (550mm+110mm+110mm+110mm) 2 8 18AWG 4 pin Molex (550mm+120mm+120mm+120mm) 2 8 18AWG 4 pin Molex (450mm+100mm+100mm+100mm) / FDD Adapter (+100mm) 1 4 / 1 18 / 22AWG
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
EVALUATION REPORT Cooler Master MPZ-C002-AFBAT
EFFICIENCY AND NOISELEVEL CERTIFICATIONS
www.cybenetics.com
CYBENETICS OFFERS THE ETA AND LAMBDA VOLUNTARY CERTIFICATION PROGRAMS, THROUGH WHICH THE EFFICIENT AND SILENT POWER SUPPLIES ARE PROMOTED
All data and graphs included in this test report can be used by any individual on the following conditions:› It should be mentioned that the test results are provided by Cybenetics› The link to the original test results document should be provided in any case
All data and graphs included in this test report can be used by any individual on the following conditions:› It should be mentioned that the test results are provided by Cybenetics› The link to the original test results document should be provided in any case
PAGE 2/9
General Data
Manufacturer (OEM) Murata Manufacturing
Platform Model -
Primary Side
Transient Filter 6x Y caps, 4x X caps, 2x CM chokes, 1x MOV, 1x CAP200DG
All data and graphs included in this test report can be used by any individual on the following conditions:› It should be mentioned that the test results are provided by Cybenetics› The link to the original test results document should be provided in any case
PAGE 3/9
RESULTS
Test Date 04-07-2017
Cybenetics ID # 85
Temperature Range (°C /°F) 30-32 / 86-89.6
Average Efficiency 91.243
Efficiency With 10W (≤500W) or 2% (>500W) Load -115V 0.000
All data and graphs included in this test report can be used by any individual on the following conditions:› It should be mentioned that the test results are provided by Cybenetics› The link to the original test results document should be provided in any case
PAGE 4/9
EFFICIENCY GRAPHINFO
This graph depicts the PSU’s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
All data and graphs included in this test report can be used by any individual on the following conditions:› It should be mentioned that the test results are provided by Cybenetics› The link to the original test results document should be provided in any case
PAGE 5/9
5VSB EFFICIENCY -115V (ERP LOT 3/6 & CEC)
Test # 5VSB DC/AC (Watts) Efficiency PF/AC Volts
10.041A 0.211
52.750%0.027
5.095V 0.400 115.12V
20.087A 0.443
64.577%0.045
5.092V 0.686 115.12V
30.532A 2.698
75.574%0.207
5.074V 3.570 115.13V
43.502A 17.439
70.569%0.504
4.980V 24.712 115.11V
5VSB EFFICIENCY -230V (ERP LOT 3/6 & CEC)
Test # 5VSB DC/AC (Watts) Efficiency PF/AC Volts
10.042A 0.212
47.111%0.009
5.094V 0.450 230.28V
20.087A 0.444
60.081%0.015
5.091V 0.739 230.28V
30.532A 2.699
73.743%0.071
5.074V 3.660 230.28V
43.502A 17.440
71.472%0.327
4.980V 24.401 230.28V
VAMPIRE POWER -115VINFO
This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing
All data and graphs included in this test report can be used by any individual on the following conditions:› It should be mentioned that the test results are provided by Cybenetics› The link to the original test results document should be provided in any case
PAGE 6/9
EFFICIENCY UNDER HIGH AMBIENT TEMPERATUREINFO
The PSU’s efficiency under high ambient temperatures
5VSB EFFICIENCYINFO
The efficiency levels of the 5VSB rail with 115V and 230V input
All data and graphs included in this test report can be used by any individual on the following conditions:› It should be mentioned that the test results are provided by Cybenetics› The link to the original test results document should be provided in any case
PAGE 7/9
10-110% LOAD TESTS
Test # 12V 5V 3.3V 5VSB DC/AC (Watts) Efficiency Fan Speed
All data and graphs included in this test report can be used by any individual on the following conditions:› It should be mentioned that the test results are provided by Cybenetics› The link to the original test results document should be provided in any case
PAGE 8/9
20-80W LOAD TESTS
Test # 12V 5V 3.3V 5VSB DC/AC (Watts) Efficiency Fan Speed (RPM) PF/AC Volts
All data and graphs included in this test report can be used by any individual on the following conditions:› It should be mentioned that the test results are provided by Cybenetics› The link to the original test results document should be provided in any case