1 2 3 4 5 6 7 8 9 10 11 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 63 64 65 67 68 69 70 71 72 73 74 75 76 2 A3-0 1 A3-1 ELECTRIC UNIT 101 827 SF UNIT 102 UNIT TYPE 5 909 SF UNIT 104 UNIT TYPE 5 920 SF UNIT 103 UNIT TYPE 4 639 SF UNIT 105 UNIT TYPE 6 684 SF UNIT 106 UNIT TYPE 3 873 SF UNIT 107 UNIT TYPE 1 1031 SF UNIT 108 UNIT TYPE 2B 955 SF UNIT 109 UNIT TYPE 2B 954 SF UNIT 110 UNIT TYPE 2 1033 SF UNIT 111 925 SF UNIT 112 1179 SF UNIT 113 1011 SF UNIT 114 1228 SF UNIT 115 1375 SF UNIT 116 1066 SF UNIT 117 797 SF UNIT 118 828 SF UNIT 120 UNIT TYPE 9 1162 SF UNIT 121 UNIT TYPE 10 732 SF UNIT 122 1117 SF UNIT 123 UNIT TYPE 13 821 SF UNIT 124 UNIT TYPE 14 1113 SF UNIT 126 630 SF UNIT 125 1299 SF UNIT 127 UNIT TYPE 11 996 SF UNIT 128 1106 SF UNIT 119 UNIT TYPE 8 544 SF 1 A3-0 ELM CITY BREWING COMPANY (RESTAURANT) EXISTING STAIR #1 EXISTING STAIR #3 EXISTING STAIR #5 ACCESSIBLE ENTRANCE ACCESSIBLE ENTRANCE WITH AUTOMATIC OPERATOR SEE PAGE A3-4.3 EXISTING ELEVATOR EXISTING ELEVATOR 5 A3-2 2 A3-2 1 A3-2 6 A3-2 ACCESSIBLE ENTRANCE DOOR TO BE FIXED SHUT NEW 90-MINUTE FIRE-RATED DOOR AT STAIRWELL TYP. DOOR TO BE FIXED SHUT 120 101 114 115 118 107 108 109 111 116 119 5'-0" 6'-0 1/4" 9'-5" 5'-3 1/4" 5'-5 3/8" 5'-0" 6'-1 1/4" 19'-3 7/8" 30'-6 7/8" 0" 29'-10 1/4" 21'-4 3/4" 20'-9 3/4" 19'-2 3/8" 19'-2 1/4" 20'-9 3/4" 19'-1" 31'-2 3/4" 5'-7 1/8" 21'-8 3/4" 26'-5 1/4" 27'-0" 20'-7 1/4" 18'-5 1/8" 29'-10 5/8" 21'-4 3/8" 30'-0 1/8" 20'-0" 32'-4 7/8" 32'-3 1/8" 20'-4 1/8" 17'-10 1/8" 32'-0 3/4" 31'-7 7/8" 13'-0 1/4" 124 126 2S11 2S12 E16 1S12 E04 E05 2S16 2S17 2S18 3W14 E10 4S12 28 E11 EXISTING WINDOWS TO REMAIN TYP. E17 E18 ACCESSIBLE ENTRANCE 127 NEW STAIR 1 A1-0 A3-2.1 3 A3-2 4 A3-2 E7 E2 E1 E3 E3 E7 E5 E5 E4 E6 E6 E4 E5 E2 E4 E1 E1 E1 E4 E6 E5 E7 E5 E5 E4 E1 E1 E1 E1 E5 E5 E5 EXISTING E1 WALL TO BE UPDATED TO AN E2 WALL - ONE LAYER 5/8" GWB ADDED TO EACH SIDE. EXISTING WINDOW TO BE INFILLED WITH TYPE E1 WALL E5 CONTRACTORS TO INSPECT EXISTING WALLS AND PROVIDE FIRE CAULKING TO ALL PENETRATIONS AS DESCRIBED ON A0-4. 8 A1-0 A3-2.1 1 A1-0 A3-4.3 E7 117 ELECTRIC ROOM 1 A2-3 2 A2-3 7'-5" 4'-1" 9'-4 13/16" 30'-9 15/16" 4'-0" - --- 1 A1-0 SK 1-2 2 A1-0 SK 1-2 EXISTING BRICK WALL 1 HOUR RATED WALLS 2 HOUR RATED WALLS 48,534 sqft EXISTING WALL NOT IN SCOPE OF WORK 30 MINUTE RATED WALLS 2x4 NOMINAL TOP PLATE ONE (1) LAYER 5/8" TYPE "X" GWB ONE (1) LAYER 5/8" TYPE "X" GWB EXISTING 3 7/8" DECKING 2x4 NOMINAL BOTTOM PLATE 2x4 NOMINAL WOOD STUDS @ 24" O.C. WALL TYPE "E1" EXISTING WALL UL DESIGN U309 1 HOUR RATING STC RATING: N/A THICKNESS: 4-7/8" E1 2x4 NOMINAL TOP PLATE TWO (2) LAYER 5/8" TYPE "X" GWB TWO (2) LAYER 5/8" TYPE "X" GWB EXISTING 3 7/8" DECKING 2x4 NOMINAL BOTTOM PLATE 2x4 NOMINAL WOOD STUDS @ 24" O.C. WALL TYPE "E2" EXISTING WALL UL DESIGN U301 2 HOUR RATING STC RATING: N/A THICKNESS: 6-1/8" E2 2x4 NOMINAL TOP PLATE ONE (1) LAYER 5/8" TYPE "X" GWB EXISTING 3 7/8" DECKING 2x4 NOMINAL BOTTOM PLATE 2x4 NOMINAL WOOD STUDS @ 24" O.C. WALL TYPE "E3" EXISTING ELEVATOR SHAFT WALL UL DESIGN N/A PER TABLE 721.3.2 2-HOUR FIRE RATING STC RATING: N/A THICKNESS: 1' 1/4" E3 CMU BRICK & MORTAR WALL TYPE "E4" EXISTING BRICK WALL UL DESIGN N/A PER TABLE 721.4.1(1) 2-HOUR FIRE RATING MINIMUM STC RATING: N/A THICKNESS: 1' 1" E4 1'-1" BRICK & MORTAR WALL TYPE "E5" EXISTING BRICK WALL UL DESIGN N/A PER TABLE 721.4.1(1) 2-HOUR FIRE RATING MINIMUM STC RATING: N/A THICKNESS: 1' 5" 1'-5" E5 BRICK & MORTAR WALL TYPE "E6" EXISTING BRICK WALL UL DESIGN N/A PER TABLE 721.4.1(1) 2-HOUR FIRE RATING MINIMUM STC RATING: N/A THICKNESS: 1' 8" 1'-8" E6 BRICK & MORTAR WALL TYPE "E7" EXISTING BRICK WALL UL DESIGN N/A PER TABLE 721.4.1(1) 2-HOUR FIRE RATING MINIMUM STC RATING: N/A THICKNESS: 2' 0" 2'-0" E7 EXISTING WALL GENERAL NOTE: CONTRACTORS TO INSPECT EXISTING WALLS AND PROVIDE FIRE CAULKING TO ALL PENETRATIONS AS DESCRIBED ON A0-4. 0' 8' 16' 32' 64' Scale: Project No.: Drawn By: 670 N. COMMERCIAL ST. MANCHESTER, NH 03101 P: 603.622.6223 F: 603.622.7342 www.bradysullivan.com Sheet Issue Date: Approved By: As indicated 8/15/2019 4:48:48 PM A1-0 PROPOSED FIRST FLOOR PLAN Project Number COLONY MILL 03/26/18 Author 222 WEST ST, KEENE, NH 03431 Approver 1/2" = 1'-0" EXISTING WALL TYPES No. Description Date
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.