MDF 107B VESTIBULE 103C RECEIVING 107 CORE INSTRUCTION-1 119-1 CORE INSTRUCTION-1 121-1 CORE INSTRUCTION 120 ART/SCIENCE 124 TEACHER PREP 116 GIRLS 112 ELEC. 114 HEALTH 110C PRINCIPAL 110B TOILET/ SHOWER/ CHANGING-1 110D-1 STAFF TOILET 127 SHARED INSTRUCTION 117 M3.2 1 MUSIC 109 STORAGE 105 DRY GOOD STORAGE 104A ELECTRICAL 108 SMALL GROUP 122 OFFICE 101A STORAGE 101B COMMUNITY STORAGE 101D RECEPTION 110 CONFERENCE 110E STORAGE 125 KILN 124A RECORDS 110G SAFETY 126 (TYP. 3) FTR-B-12 (TYP. 3) (TYP. 3) 24X24 G-1 900 CFM FTR-B-9A 24X24 G-1 900 CFM 24X24 G-1 900 CFM (TYP. 6) (TYP. 3) AC-1 8"Ø D-1 250 CFM 8"Ø D-1 200 CFM 8"Ø D-1 220 CFM 8"Ø D-3 170 CFM 8"Ø D-1 225 CFM 6"Ø D-3 70 CFM 8"Ø D-1 125 CFM (TYP. 2) WORKROOM 110H VAV-2-2 VAV-3-9 VAV-3-5 VAV-3-3 VAV-3-2 VAV-3-1 FABRIC DUCT CORRIDOR 100-C OFFICE 110F MUSIC STORAGE 109A COMMONS 103 CORE INSTRUCTION 118 16"Ø D-4 360 CFM 20"ø 20"ø VAV-2-3 (TYP. 6) 24X36 G-2 1200 CFM KITCHEN 104 BOILER ROOM 102 FREEZER 104C 1 M3.5 EF-A-6 EF-A-5 EF-A-1 EF-A-2 12X12 G-4 100 CFM 12X12 G-4 120 CFM 12X12 G-4 20 CFM IDF 113 GIRLS 115 BOYS 123 VESTIBULE 100B VESTIBULE 100A CORRIDOR 100C 10"ø 8"ø 6"ø 8"ø 8"ø ENTRY LOBBY-1 100-1 Entry Lobby 3 100-3 Entry Lobby 1 100 VAV-3-6 6"ø 6"ø 6"Ø D-2 30 CFM 8"Ø D-3 125 CFM 8" ø CORRIDOR 110A 10 "ø VAV-3-13 EF-B-12 C O 2 C O 2 C O2 C O 2 C O2 C O 2 C O2 C O 2 10"ø 26/16 EA DN TO TYPE I GREASE HOOD. SEE FOOD SERVICE FS1.1 FOR RA/SA CONTINUATION, SEE M3.1 FOR RA/SA CONTINUATION, SEE M3.1 34/20 RA DN TO RETURN AIR PLENUM IN STAIR, BALANCE TO 3840 CFM FTR-B-1 FTR-B-3 FTR-B-4 FTR-B-11A FTR-B-10A FTR-B-13 FTR-C-3 BOYS 111 EF-B-6 EF-B-5 EF-B-4 12x12 G-2 210 CFM 12x12 G-2 210 CFM EF-B-1 EF-B-3 EF-B-2 10 "ø 12 "ø 1 0 "ø 1 2 "ø 6"ø 8"ø (TYP. 3) 16"/12" 36X24 RA UP 36X24 SA UP 8"Ø D-1 190 CFM (TYP. 2) 10"ø C1 C2 C4 C8 CA BB BD B8 B2 BC BF A5 C11 C12 CN BP BN BE B11 B12 B13 BG B5 AB C13 C3 BR BA AG AD A9 A8 B4 B7 A4 AC BS A3 AF AK C5 C14 A1 AE B14 AL B6 B3 AJ A10 A2 BH AH AD.7 AA B1 A0.5 X2 X1 XA X4 XB C6 C9 BQ B3.9 X3 8" ø 8"Ø D-6 185 CFM 16"Ø SA UP REF M1.3 FOR CONT. 12"ø 10"ø 8"Ø D-6 185 CFM (TYP. 3) (TYP. 3) 12 "ø 10 "ø 8"Ø D-7 125 CFM (TYP. 2) VAV-3-12 (TYP. 2) 12"/8" 24X24 G-1 220 CFM 8"ø 8"ø 24X24 G-1 250 CFM 24X24 G-1 380 CFM 12"ø VAV-3-11 1 6 "ø 6"Ø D-2 50 CFM 8"Ø D-7 125 CFM FTR-C-7A 8"Ø D-7 150 CFM (TYP. 2) 24X24 G-1 225 CFM 8"Ø D-7 125 CFM 1 0 "ø 6"ø 6"ø 24X16 G-2 1250 CFM 24X16 G-2 1250 CFM 24X24 G-1 400 CFM 12" /10" 10 "/8" 24X24 G-1 250 CFM 40"X20" RA UP VAV-3-14 VAV-3-7 16"/14" VAV-3-15 10 "ø 8"ø VAV-3-4 8" ø 6"ø 10" /8" 10 "ø 6"Ø D-2 50 CFM VAV-5-1 VAV-5-3 VAV-5-4 12"ø 12"Ø D-9 625 CFM (TYP 4) 16"/10" 10/6 DN. CONNECT TO DISHWASHER HOOD (ITEM 13) 12 " ø 12 " ø 12 " ø 10"Ø DT-1 300 CFM 10"Ø DT-1 300 CFM 20"/14" 24"/18" 1 0 "ø 1 2 "ø AC-2 LV-A01 450 CFM EF-A-7 LV-A02 175 CFM LV-A03 50 CFM LV-A4 110 CFM 10"ø LV-A6 300 CFM 16"ø 16"ø UH-A-2 UP TO RAH-A1 ON RF UH-A-3 UH-A-4 20"ø C O 2 UH-A-7 UH-A-5 UH-A-6 16X8 G-2 8"/8" 24X24 G-1 70 CFM 6"/6" 6"ø 16"ø 8"ø LV-B-3 560 CFM LV-A-5 290 CFM 10X10 G-1 290 CFM 16X8 G-2 290 CFM 10X10 G-1 290 CFM 10"ø LV-B-1 140 CFM 8" ø 16"/12" LV-B-4 140 CFM 8"ø 36X48 G-3 4200 CFM M M 10"/10" 10"/10" 24"ø TRANSITION TO FABRIC DUCT 1 1 1 18"ø 2 16"Ø D-4 360 CFM 2 1 1 1 30"ø 12X12 70 CFM EF-B-10 LV-B-5 600 CFM 34"/20" 1 4"ø 30"X22" SA UP 8"Ø D-7 125 CFM FTR-B-20 FTR-B-22 FTR-C-19A 34 M 5.1 25 M 5.1 15 M 5.1 (TYP.) M M 12"/10" 8"Ø D-3 200 CFM 4 M3.4 24X24 G-1 100 CFM 6"Ø D-1 100 CFM VAV-3-8 8"Ø EA DN TO EF-B-11 8"ø FTR-B-29 EMERGENCY SUPPLIES 106 MATCHLINE - SEE M1.2 MATCHLINE - SEE M1.2 8"Ø EA DN TO RANGE HOOD 8"ø LV-B15 250 CFM LV-B16 150 CFM ELECTRICAL 107A VESTIBULE 103A 24X24 G-1 900 CFM 8"ø VAV-3-10 16" /12" C O2 PROVIDE FLEXIBLE DUCT CONNECTION AT SEISMIC JOINT 10 "ø 14"ø 10 "ø 10"Ø D-8 200 CFM (TYP. 3) 10"Ø D-8 200 CFM 12"ø 12"ø 14"/10" 12"ø 12"ø 16"ø 24"ø (TYP. 3) VAV-5-11 14 " ø VAV-5-2 FTR-B-2 FTR-B-6 FTR-A-1 300 CFM 8"ø 12"ø 18"ø TO VAV 2-2 C O 2 TO VAV-3-13 6"ø 10"ø 14"ø 24X24 G-1 1250 CFM LV-A13 450 CFM 36 M 5.1 EMCS CONTROLLER C O2 C O 2 C O2 C O 2 C O 2 C O 2 FTR-A-2 3 3 4 6 4" Ø DRYER EXHAUST 44 M 5.2 5 2 M 3.2 BASE BID ALTERNATE #1 3 M3.6 FABRIC DUCT 8"ø 6"Ø D-2 60 CFM 6"Ø D-2 75 CFM EF-A-8 SEE DETAIL 54/M5.1 FOR CEILING MOUNTED EXHAUST FAN (TYP). 7 7 EF-B-13 8 9 M 10 10 18"ø 4 8"ø 6"ø 8"ø 6 24X12 G-4 900 CFM 30"/22" 30" /16" 30"/16" 28"/16" 26"/16" 24"/16" 40"/20" 22"/18" 20"/16" 20" /14" VAV-5-10 1 8" /1 2" 20"/16" 24X24 G-1 500 CFM 2 0" /1 6" 10"Ø DT-1 300 CFM 10"Ø DT-1 300 CFM 22"/14" 10 " ø 10 " ø 12 " ø 14 " ø 10"ø 10"ø 10 " ø 10"ø 10 " ø 14"ø 16"/12" 24X24 G-1 1200 CFM 16"/12" 22"/14" 28"/20" 10"ø 10"Ø DT-1 300 CFM 14"ø 22"/16" 22"/18" 26" / 18" 12"ø 36"/24" 16"ø 12 " ø 11 24"/16" 14"/16" 24"/12" 24"/12" 12 (TYP 2) 13 13 10"Ø DT-1 300 CFM (TYP. 4) 18"/12" 26"/20" 30"/22" S 14 6"ø 6"ø TO VAV-3-11 TO VAV-3-10 UH-B1 CUH-1 12X12 D-2 290 CFM 16"ø UP EF-B-14 STORAGE 101F VEST 101E TO VAV-2-1 10"ø 10"ø 10 " ø 14"ø 10 " ø 14"ø 10"ø 14"ø 30"Ø DN TRANSITION TO 34"/20" IN DROP 6"ø FD 12x12 G-2 175 CFM (TYP. 2) MAU-1 (ON ROOF) 4 M3.5 FD 54 M5.2 12x12 G-1 100 CFM 24x24 G-1 125 CFM 24x24 G-1 210 CFM FTR-B-10B FTR-B-11B FTR-B-9B 15 TYP ALL DT-1 AND DT-2 DIFFUSERS 120 x 6 G-6 120 x 12 G-5 32 M5.1 FTR-B-24B FTR-B-24A FTR-C-19B FTR RECESSED IN WALL. SEE 23/A11.9 FOR FTR MOUNTING DETAIL. 24x24 G-6 500 CFM 12x12 G-2 500 CFM 12"/12" GREASE EXHAUST DUCT DISHWASHER EXHAUST DUCT 10"/6" 1 M3.7 1 KEY NOTES ROTATE DIFFUSER DISCHARGE 25° AWAY FROM WALL. COORDINATE DIFFUSER THROWS WITH LIGHT FIXTURES. FABRIC DUCT TO FOLLOW SLOPE OF STRUCTURE MOUNT BOTTOM OF GRILLE 6" AFF INTERLOCK W/ EF-A-1 PLENUM WITH PARTITION PROVIDE SHEET METAL ENCLOSURE FOR VAV BOX WITH ACOUSTICAL LAGGING. 10"X6" EA UP TO EF-A-4 ON ROOF. 16"X10" EA UP TO EF-A-3 ON ROOF. PROVIDE FLAT RECTANGULAR 18 GA GALV SHT MTL UNDERPAN W/ 1” H HEMMED EDGE AT VAV BOXES WHERE EXPOSED TO VIEW. LENGTH AND WIDTH TO EXCEED EXTENT OF LAGGING BY 2” IN EA DIRECTION. ATTACH TO UNIT FRAMING, NOT UNIT. DO NOT OBSTRUCT MAINTENANCE OR OPERATION ACCESS. MAINTAIN 1” CLEARANCE MIN AT UNIT. PAINT TO MATCH ADJACENT FLOOR/ROOF DECK COLOR. 24"X24" UP TO MAU-1 ON ROOF 16"X24" UP TO MAU-1 ON ROOF INTERLOCK FAN & UNIT HEATER TO PREVENT SIMULTANEOUS OPERATION. 5° DEADBAND MINIMUM. DOOR OPEN SENSOR DIFFUSER LOCATION SHOWN IS APPROXIMATE. FOR EXACT DISPLACEMENT DIFFUSER LOCATIONS, REFERENCE A11.X SERIES ARCHITECTURAL INTERIOR ELEVATIONS. 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Architecture Engineering Planning Interiors © , DLR Group inc., a Washington corporation, ALL RIGHTS RESERVED KEY PLAN D C B A NORTH BENJAMIN TALPOS Revisions 7/20/2012 3:43:22 PM C:\Users\dluzius\Documents\^Revit\73-10122-00\73-10122-00_local(dluzius)_MEP_2011.rvt 73-10122-00 07/23/2012 ALEXANDER GRAHAM BELL ELEMENTARY SCHOOL CONFORMED SET FIRST LEVEL HVAC PLAN - AREA A/B M1.1 2012 Lake Washington School District SCALE: 1/8" = 1'-0" FIRST LEVEL HVAC PLAN - AREA A/B NORTH