Top Banner
MDF 107B VESTIBULE 103C RECEIVING 107 CORE INSTRUCTION-1 119-1 CORE INSTRUCTION-1 121-1 CORE INSTRUCTION 120 ART/SCIENCE 124 TEACHER PREP 116 GIRLS 112 ELEC. 114 HEALTH 110C PRINCIPAL 110B TOILET/ SHOWER/ CHANGING-1 110D-1 STAFF TOILET 127 SHARED INSTRUCTION 117 M3.2 1 MUSIC 109 STORAGE 105 DRY GOOD STORAGE 104A ELECTRICAL 108 SMALL GROUP 122 OFFICE 101A STORAGE 101B COMMUNITY STORAGE 101D RECEPTION 110 CONFERENCE 110E STORAGE 125 KILN 124A RECORDS 110G SAFETY 126 (TYP. 3) FTR-B-12 (TYP. 3) (TYP. 3) 24X24 G-1 900 CFM FTR-B-9A 24X24 G-1 900 CFM 24X24 G-1 900 CFM (TYP. 6) (TYP. 3) AC-1 8"Ø D-1 250 CFM 8"Ø D-1 200 CFM 8"Ø D-1 220 CFM 8"Ø D-3 170 CFM 8"Ø D-1 225 CFM 6"Ø D-3 70 CFM 8"Ø D-1 125 CFM (TYP. 2) WORKROOM 110H VAV-2-2 VAV-3-9 VAV-3-5 VAV-3-3 VAV-3-2 VAV-3-1 FABRIC DUCT CORRIDOR 100-C OFFICE 110F MUSIC STORAGE 109A COMMONS 103 CORE INSTRUCTION 118 16"Ø D-4 360 CFM 20"ø 20"ø VAV-2-3 (TYP. 6) 24X36 G-2 1200 CFM KITCHEN 104 BOILER ROOM 102 FREEZER 104C 1 M3.5 EF-A-6 EF-A-5 EF-A-1 EF-A-2 12X12 G-4 100 CFM 12X12 G-4 120 CFM 12X12 G-4 20 CFM IDF 113 GIRLS 115 BOYS 123 VESTIBULE 100B VESTIBULE 100A CORRIDOR 100C 10"ø 8"ø 6"ø 8"ø 8"ø ENTRY LOBBY-1 100-1 Entry Lobby 3 100-3 Entry Lobby 1 100 VAV-3-6 6"ø 6"ø 6"Ø D-2 30 CFM 8"Ø D-3 125 CFM 8" ø CORRIDOR 110A 10 VAV-3-13 EF-B-12 C O 2 C O 2 C O2 C O 2 C O2 C O 2 C O2 C O 2 10"ø 26/16 EA DN TO TYPE I GREASE HOOD. SEE FOOD SERVICE FS1.1 FOR RA/SA CONTINUATION, SEE M3.1 FOR RA/SA CONTINUATION, SEE M3.1 34/20 RA DN TO RETURN AIR PLENUM IN STAIR, BALANCE TO 3840 CFM FTR-B-1 FTR-B-3 FTR-B-4 FTR-B-11A FTR-B-10A FTR-B-13 FTR-C-3 BOYS 111 EF-B-6 EF-B-5 EF-B-4 12x12 G-2 210 CFM 12x12 G-2 210 CFM EF-B-1 EF-B-3 EF-B-2 10 12 1 0 1 2 6"ø 8"ø (TYP. 3) 16"/12" 36X24 RA UP 36X24 SA UP 8"Ø D-1 190 CFM (TYP. 2) 10"ø C1 C2 C4 C8 CA BB BD B8 B2 BC BF A5 C11 C12 CN BP BN BE B11 B12 B13 BG B5 AB C13 C3 BR BA AG AD A9 A8 B4 B7 A4 AC BS A3 AF AK C5 C14 A1 AE B14 AL B6 B3 AJ A10 A2 BH AH AD.7 AA B1 A0.5 X2 X1 XA X4 XB C6 C9 BQ B3.9 X3 8" ø 8"Ø D-6 185 CFM 16"Ø SA UP REF M1.3 FOR CONT. 12"ø 10"ø 8"Ø D-6 185 CFM (TYP. 3) (TYP. 3) 12 10 8"Ø D-7 125 CFM (TYP. 2) VAV-3-12 (TYP. 2) 12"/8" 24X24 G-1 220 CFM 8"ø 8"ø 24X24 G-1 250 CFM 24X24 G-1 380 CFM 12"ø VAV-3-11 1 6 6"Ø D-2 50 CFM 8"Ø D-7 125 CFM FTR-C-7A 8"Ø D-7 150 CFM (TYP. 2) 24X24 G-1 225 CFM 8"Ø D-7 125 CFM 1 0 6"ø 6"ø 24X16 G-2 1250 CFM 24X16 G-2 1250 CFM 24X24 G-1 400 CFM 12" /10" 10 "/8" 24X24 G-1 250 CFM 40"X20" RA UP VAV-3-14 VAV-3-7 16"/14" VAV-3-15 10 8"ø VAV-3-4 8" ø 6"ø 10" /8" 10 6"Ø D-2 50 CFM VAV-5-1 VAV-5-3 VAV-5-4 12"ø 12"Ø D-9 625 CFM (TYP 4) 16"/10" 10/6 DN. CONNECT TO DISHWASHER HOOD (ITEM 13) 12 " ø 12 " ø 12 " ø 10"Ø DT-1 300 CFM 10"Ø DT-1 300 CFM 20"/14" 24"/18" 1 0 1 2 AC-2 LV-A01 450 CFM EF-A-7 LV-A02 175 CFM LV-A03 50 CFM LV-A4 110 CFM 10"ø LV-A6 300 CFM 16"ø 16"ø UH-A-2 UP TO RAH-A1 ON RF UH-A-3 UH-A-4 20"ø C O 2 UH-A-7 UH-A-5 UH-A-6 16X8 G-2 8"/8" 24X24 G-1 70 CFM 6"/6" 6"ø 16"ø 8"ø LV-B-3 560 CFM LV-A-5 290 CFM 10X10 G-1 290 CFM 16X8 G-2 290 CFM 10X10 G-1 290 CFM 10"ø LV-B-1 140 CFM 8" ø 16"/12" LV-B-4 140 CFM 8"ø 36X48 G-3 4200 CFM M M 10"/10" 10"/10" 24"ø TRANSITION TO FABRIC DUCT 1 1 1 18"ø 2 16"Ø D-4 360 CFM 2 1 1 1 30"ø 12X12 70 CFM EF-B-10 LV-B-5 600 CFM 34"/20" 1 4"ø 30"X22" SA UP 8"Ø D-7 125 CFM FTR-B-20 FTR-B-22 FTR-C-19A 34 M 5.1 25 M 5.1 15 M 5.1 (TYP.) M M 12"/10" 8"Ø D-3 200 CFM 4 M3.4 24X24 G-1 100 CFM 6"Ø D-1 100 CFM VAV-3-8 8"Ø EA DN TO EF-B-11 8"ø FTR-B-29 EMERGENCY SUPPLIES 106 MATCHLINE - SEE M1.2 MATCHLINE - SEE M1.2 8"Ø EA DN TO RANGE HOOD 8"ø LV-B15 250 CFM LV-B16 150 CFM ELECTRICAL 107A VESTIBULE 103A 24X24 G-1 900 CFM 8"ø VAV-3-10 16" /12" C O2 PROVIDE FLEXIBLE DUCT CONNECTION AT SEISMIC JOINT 10 14"ø 10 10"Ø D-8 200 CFM (TYP. 3) 10"Ø D-8 200 CFM 12"ø 12"ø 14"/10" 12"ø 12"ø 16"ø 24"ø (TYP. 3) VAV-5-11 14 " ø VAV-5-2 FTR-B-2 FTR-B-6 FTR-A-1 300 CFM 8"ø 12"ø 18"ø TO VAV 2-2 C O 2 TO VAV-3-13 6"ø 10"ø 14"ø 24X24 G-1 1250 CFM LV-A13 450 CFM 36 M 5.1 EMCS CONTROLLER C O2 C O 2 C O2 C O 2 C O 2 C O 2 FTR-A-2 3 3 4 6 4" Ø DRYER EXHAUST 44 M 5.2 5 2 M 3.2 BASE BID ALTERNATE #1 3 M3.6 FABRIC DUCT 8"ø 6"Ø D-2 60 CFM 6"Ø D-2 75 CFM EF-A-8 SEE DETAIL 54/M5.1 FOR CEILING MOUNTED EXHAUST FAN (TYP). 7 7 EF-B-13 8 9 M 10 10 18"ø 4 8"ø 6"ø 8"ø 6 24X12 G-4 900 CFM 30"/22" 30" /16" 30"/16" 28"/16" 26"/16" 24"/16" 40"/20" 22"/18" 20"/16" 20" /14" VAV-5-10 1 8" /1 2" 20"/16" 24X24 G-1 500 CFM 2 0" /1 6" 10"Ø DT-1 300 CFM 10"Ø DT-1 300 CFM 22"/14" 10 " ø 10 " ø 12 " ø 14 " ø 10"ø 10"ø 10 " ø 10"ø 10 " ø 14"ø 16"/12" 24X24 G-1 1200 CFM 16"/12" 22"/14" 28"/20" 10"ø 10"Ø DT-1 300 CFM 14"ø 22"/16" 22"/18" 26" / 18" 12"ø 36"/24" 16"ø 12 " ø 11 24"/16" 14"/16" 24"/12" 24"/12" 12 (TYP 2) 13 13 10"Ø DT-1 300 CFM (TYP. 4) 18"/12" 26"/20" 30"/22" S 14 6"ø 6"ø TO VAV-3-11 TO VAV-3-10 UH-B1 CUH-1 12X12 D-2 290 CFM 16"ø UP EF-B-14 STORAGE 101F VEST 101E TO VAV-2-1 10"ø 10"ø 10 " ø 14"ø 10 " ø 14"ø 10"ø 14"ø 30"Ø DN TRANSITION TO 34"/20" IN DROP 6"ø FD 12x12 G-2 175 CFM (TYP. 2) MAU-1 (ON ROOF) 4 M3.5 FD 54 M5.2 12x12 G-1 100 CFM 24x24 G-1 125 CFM 24x24 G-1 210 CFM FTR-B-10B FTR-B-11B FTR-B-9B 15 TYP ALL DT-1 AND DT-2 DIFFUSERS 120 x 6 G-6 120 x 12 G-5 32 M5.1 FTR-B-24B FTR-B-24A FTR-C-19B FTR RECESSED IN WALL. SEE 23/A11.9 FOR FTR MOUNTING DETAIL. 24x24 G-6 500 CFM 12x12 G-2 500 CFM 12"/12" GREASE EXHAUST DUCT DISHWASHER EXHAUST DUCT 10"/6" 1 M3.7 1 KEY NOTES ROTATE DIFFUSER DISCHARGE 25° AWAY FROM WALL. COORDINATE DIFFUSER THROWS WITH LIGHT FIXTURES. FABRIC DUCT TO FOLLOW SLOPE OF STRUCTURE MOUNT BOTTOM OF GRILLE 6" AFF INTERLOCK W/ EF-A-1 PLENUM WITH PARTITION PROVIDE SHEET METAL ENCLOSURE FOR VAV BOX WITH ACOUSTICAL LAGGING. 10"X6" EA UP TO EF-A-4 ON ROOF. 16"X10" EA UP TO EF-A-3 ON ROOF. PROVIDE FLAT RECTANGULAR 18 GA GALV SHT MTL UNDERPAN W/ 1” H HEMMED EDGE AT VAV BOXES WHERE EXPOSED TO VIEW. LENGTH AND WIDTH TO EXCEED EXTENT OF LAGGING BY 2” IN EA DIRECTION. ATTACH TO UNIT FRAMING, NOT UNIT. DO NOT OBSTRUCT MAINTENANCE OR OPERATION ACCESS. MAINTAIN 1” CLEARANCE MIN AT UNIT. PAINT TO MATCH ADJACENT FLOOR/ROOF DECK COLOR. 24"X24" UP TO MAU-1 ON ROOF 16"X24" UP TO MAU-1 ON ROOF INTERLOCK FAN & UNIT HEATER TO PREVENT SIMULTANEOUS OPERATION. 5° DEADBAND MINIMUM. DOOR OPEN SENSOR DIFFUSER LOCATION SHOWN IS APPROXIMATE. FOR EXACT DISPLACEMENT DIFFUSER LOCATIONS, REFERENCE A11.X SERIES ARCHITECTURAL INTERIOR ELEVATIONS. 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Architecture Engineering Planning Interiors © , DLR Group inc., a Washington corporation, ALL RIGHTS RESERVED KEY PLAN D C B A NORTH BENJAMIN TALPOS Revisions 7/20/2012 3:43:22 PM C:\Users\dluzius\Documents\^Revit\73-10122-00\73-10122-00_local(dluzius)_MEP_2011.rvt 73-10122-00 07/23/2012 ALEXANDER GRAHAM BELL ELEMENTARY SCHOOL CONFORMED SET FIRST LEVEL HVAC PLAN - AREA A/B M1.1 2012 Lake Washington School District SCALE: 1/8" = 1'-0" FIRST LEVEL HVAC PLAN - AREA A/B NORTH
1

C:UsersdluziusDocuments^Revit73-10122-0073-10122-00 … · 2015. 8. 21. · kitchen 104 boiler room 102 freezer 104c 1 m3.5 ef-a-6 ef-a-5 ef-a-1 ef-a-2 12x12 g-4 100 cfm 12x12 g-4

Mar 22, 2021

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: C:UsersdluziusDocuments^Revit73-10122-0073-10122-00 … · 2015. 8. 21. · kitchen 104 boiler room 102 freezer 104c 1 m3.5 ef-a-6 ef-a-5 ef-a-1 ef-a-2 12x12 g-4 100 cfm 12x12 g-4

MDF

107B

VESTIBULE

103C

RECEIVING

107

CORE INSTRUCTION-1

119-1

CORE INSTRUCTION-1

121-1

CORE INSTRUCTION

120

ART/SCIENCE

124

TEACHER PREP

116

GIRLS

112

ELEC.

114HEALTH

110C

PRINCIPAL

110BTOILET/ SHOWER/

CHANGING-1

110D-1

STAFF TOILET

127

SHARED INSTRUCTION

117

M3.21

MUSIC

109

STORAGE

105

DRY GOOD STORAGE

104AELECTRICAL

108

SMALL GROUP

122

OFFICE

101A

STORAGE

101B

COMMUNITY STORAGE

101D

RECEPTION

110

CONFERENCE

110E

STORAGE

125

KILN

124A

RECORDS

110G

SAFETY

126

(TYP. 3)

FTR-B-12

(TYP. 3)

(TYP. 3)

24X24 G-1900 CFM

FTR-B-9A

24X24 G-1900 CFM

24X24 G-1900 CFM

(TYP. 6) (TYP. 3)

AC-1

8"Ø D-1250 CFM

8"Ø D-1200 CFM

8"Ø D-1220 CFM

8"Ø D-3170 CFM

8"Ø D-1225 CFM

6"Ø D-370 CFM

8"Ø D-1125 CFM(TYP. 2)

WORKROOM

110H

VAV-2-2

VAV-3-9

VAV-3-5

VAV-3-3

VAV-3-2

VAV-3-1

FABR

IC D

UCT

CORRIDOR

100-C

OFFICE

110F

MUSIC STORAGE

109A

COMMONS

103

CORE INSTRUCTION

118

16"Ø D-4360 CFM

20"ø

20"ø

VAV-2-3

(TYP. 6)

24X36 G-21200 CFM

KITCHEN

104

BOILER ROOM

102

FREEZER

104C1

M3.5

EF-A-6

EF-A-5

EF-A-1

EF-A-2

12X12 G-4100 CFM

12X12 G-4120 CFM

12X12 G-420 CFM

IDF

113

GIRLS

115

BOYS

123

VESTIBULE

100B

VESTIBULE

100A

CORRIDOR

100C

10"ø

8"ø6"ø

8"ø

8"ø

ENTRY LOBBY-1

100-1

Entry Lobby 3

100-3

Entry Lobby 1

100

VAV-3-6

6"ø

6"ø

6"Ø D-230 CFM

8"Ø D-3125 CFM

8"ø

CORRIDOR

110A

10"ø

VAV-3-13

EF-B-12

CO2

C O2

CO2

C O2

CO2

C O2

CO

2

C O2

10"ø

26/16 EA DN TOTYPE I GREASEHOOD. SEE FOODSERVICE FS1.1

FOR RA/SACONTINUATION,SEE M3.1

FOR RA/SACONTINUATION,SEE M3.1

34/20 RA DNTO RETURNAIR PLENUMIN STAIR,BALANCE TO3840 CFM

FTR-B-1

FTR-B-3

FTR-B-4

FTR-B-11A

FTR-B-10A

FTR-B-13

FTR-C-3

BOYS

111

EF-B-6

EF-B-5

EF-B-4

12x12 G-2210 CFM

12x12 G-2210 CFM

EF-B-1

EF-B-3

EF-B-2

10"ø

12"ø

10"ø

12"ø

6"ø

8"ø

(TYP. 3)

16"/12"

36X24RA UP

36X24SA UP

8"Ø D-1190 CFM

(TYP. 2)

10"ø

C1C2

C4

C8

CA

BB

BD

B8

B2

BC

BF

A5

C11C12

C18

CN

BP

BN

BE

B11

B12

B13

BG

B5

AB

C13

C3

BR

BA

AG

AD

A9A8

B4

B7

A4

AC

BS

A3

AF

AK

C5

C14

A1

AE

B14

AL

B6

B3

AJ

A10

A2

BH

AH

AD.7

AA

B1

A0.5

X2

X1

XA

X4

XB

C6

C9

BQ

B3.9

X3

8"ø

8"Ø D-6185 CFM

16"Ø SA UPREF M1.3FOR CONT.

12"ø

10"ø

8"Ø D-6185 CFM

(TYP. 3)

(TYP. 3)

12"ø10"ø

8"Ø D-7125 CFM

(TYP. 2)

VAV-3-12

(TYP. 2)

12"/8"

24X24 G-1220 CFM

8"ø

8"ø

24X24 G-1250 CFM

24X24 G-1380 CFM

12"ø

VAV-3-1116"ø

6"Ø D-250 CFM

8"Ø D-7125 CFM

FTR-C-7A

8"Ø D-7150 CFM

(TYP. 2)

24X24 G-1225 CFM

8"Ø D-7125 CFM

10"ø

6"ø

6"ø

24X16 G-21250 CFM

24X16 G-21250 CFM

24X24 G-1400 CFM

12"/10"

10"/8" 24X24 G-1250 CFM

40"X20"RA UP

VAV-3-14

VAV-3-7

16"/1

4"

VAV-3-15

10"ø

8"ø VAV-3-48"ø

6"ø

10"/8"

10"ø

6"Ø D-250 CFM

VAV-5-1

VAV-5-3

VAV-5-4

12"ø

12"Ø D-9625 CFM

(TYP 4)

16"/10"

10/6 DN. CONNECT TODISHWASHER HOOD (ITEM 13)

12"ø

12"ø

12"ø

10"Ø DT-1300 CFM

10"Ø DT-1300 CFM

20"/14"

24"/18"

10"ø

12"ø

AC-2

LV-A01450 CFM

EF-A-7

LV-A02175 CFM

LV-A0350 CFM

LV-A4110 CFM

10"ø

LV-A6300 CFM

16"ø

16"ø

UH-A-2

UP TORAH-A1ON RF

UH-A-3 UH-A-4

20"ø

C O2

UH-A-7 UH-A-5

UH-A-6

16X8 G-2

8"/8"

24X24 G-170 CFM

6"/6"

6"ø

16"ø

8"ø

LV-B-3560 CFM

LV-A-5290 CFM

10X10 G-1290 CFM

16X8 G-2290 CFM

10X10 G-1290 CFM

10"ø

LV-B-1140 CFM

8"ø

16"/12"

LV-B-4140 CFM

8"ø

36X48 G-34200 CFM

M M

10"/10"

10"/1

0"

24"ø

TRANSITION TOFABRIC DUCT

1

1

1

18"ø

2 16"Ø D-4360 CFM2

1

1

1

30"ø

12X1270 CFM

EF-B-10

LV-B-5600 CFM

34"/20"

14"ø

30"X22"SA UP

8"Ø D-7125 CFM

FTR-B-20

FTR-B-22

FTR-C-19A

34 M 5.1

25 M 5.1

15 M 5.1 (TYP.)

M

M12"/10"

8"Ø D-3200 CFM

4M3.4

24X24 G-1100 CFM

6"Ø D-1100 CFM

VAV-3-8

8"Ø EA DN TO EF-B-11

8"ø

FTR-B-29

EMERGENCY SUPPLIES

106

MATCHLINE - SEE M1.2 MATCHLINE - SEE M1.2

8"Ø EA DN TORANGE HOOD

8"ø

LV-B15250 CFM

LV-B16150 CFM

ELECTRICAL

107A

VESTIBULE

103A

24X24 G-1900 CFM

8"ø

VAV-3-10

16"/12"

C O2

PROVIDE FLEXIBLE DUCTCONNECTION AT SEISMICJOINT

10"ø

14"ø

10"ø

10"Ø D-8200 CFM

(TYP. 3)

10"Ø D-8200 CFM

12"ø

12"ø

14"/10"12"ø12"ø

16"ø24"ø

(TYP. 3)

VAV-5-11

14"ø

VAV-5-2

FTR-B-2

FTR-B-6

FTR-A-1

300 CFM

8"ø

12"ø

18"ø

TO VAV 2-2

CO2

TO VAV-3-13

6"ø

10"ø

14"ø

24X24 G-11250 CFM

LV-A13450 CFM

36 M 5.1

EMCSCONTROLLER

C O2

C O2

C O2

C O2

CO2

C O2

FTR-A-23

3

4

6

4" Ø DRYEREXHAUST

44 M 5.2

5

2 M 3.2

BASE BID

ALTERNATE #1

3M3.6

FABRIC DUCT

8"ø

6"Ø D-260 CFM

6"Ø D-275 CFM

EF-A-8

SEE DETAIL 54/M5.1FOR CEILINGMOUNTED EXHAUSTFAN (TYP).

7

7

EF-B-13

8

9

M

10

10

18"ø

4

8"ø

6"ø

8"ø

6

24X12 G-4900 CFM

30"/22"

30"/16"

30"/16"28"/16"

26"/1

6"24

"/16"

40"/20"

22"/18"

20"/16"

20"/14"

VAV-5-10

18"/12"

20"/16"

24X24 G-1500 CFM

20"/16"

10"Ø DT-1300 CFM

10"Ø DT-1300 CFM

22"/14"

10"ø

10"ø

12"ø

14"ø 10"ø

10"ø

10"ø

10"ø

10"ø

14"ø

16"/12"

24X24 G-11200 CFM

16"/12"

22"/14"

28"/20"

10"ø

10"Ø DT-1300 CFM

14"ø

22"/16"

22"/18"

26"/18"

12"ø

36"/24"

16"ø

12"ø

11

24"/16"14"/16"

24"/1

2"

24"/12"12(TYP 2)

13

13

10"Ø DT-1300 CFM

(TYP. 4)

18"/12"

26"/20"

30"/22"

S

14

6"ø

6"øTO VAV-3-11

TO VAV-3-10

UH-B1

CUH-1

12X12 D-2290 CFM

16"ø UP

EF-B-14

STORAGE

101F

VEST

101E

TO VAV-2-1

10"ø

10"ø10"ø

14"ø

10"ø

14"ø

10"ø

14"ø

30"Ø DNTRANSITIONTO 34"/20"IN DROP

6"ø

FD

12x12 G-2175 CFM(TYP. 2)

MAU-1(ON ROOF)

4M3.5

FD

54M5.2

12x12 G-1100 CFM

24x24 G-1125 CFM

24x24 G-1210 CFM

FTR-B-10B

FTR-B-11B

FTR-B-9B

15 TYP ALL DT-1 ANDDT-2 DIFFUSERS

120 x 6 G-6120 x 12 G-5

32M5.1

FTR-B-24BFTR-B-24A

FTR-C-19B

FTR RECESSED IN WALL.SEE 23/A11.9 FOR FTRMOUNTING DETAIL.

24x24 G-6500 CFM

12x12 G-2500 CFM

12"/12"

GREASEEXHAUST DUCT

DISHWASHEREXHAUST DUCT

10"/6

"

1M3.7

1

KEY NOTESROTATE DIFFUSER DISCHARGE 25° AWAY FROM WALL.

COORDINATE DIFFUSER THROWS WITH LIGHT FIXTURES.

FABRIC DUCT TO FOLLOW SLOPE OF STRUCTURE

MOUNT BOTTOM OF GRILLE 6" AFF

INTERLOCK W/ EF-A-1

PLENUM WITH PARTITION

PROVIDE SHEET METAL ENCLOSURE FOR VAV BOX WITHACOUSTICAL LAGGING.

10"X6" EA UP TO EF-A-4 ON ROOF.

16"X10" EA UP TO EF-A-3 ON ROOF.

PROVIDE FLAT RECTANGULAR 18 GA GALV SHT MTLUNDERPAN W/ 1” H HEMMED EDGE AT VAV BOXES WHEREEXPOSED TO VIEW. LENGTH AND WIDTH TO EXCEED EXTENTOF LAGGING BY 2” IN EA DIRECTION. ATTACH TO UNITFRAMING, NOT UNIT. DO NOT OBSTRUCT MAINTENANCE OROPERATION ACCESS. MAINTAIN 1” CLEARANCE MIN AT UNIT.PAINT TO MATCH ADJACENT FLOOR/ROOF DECK COLOR.

24"X24" UP TO MAU-1 ON ROOF

16"X24" UP TO MAU-1 ON ROOF

INTERLOCK FAN & UNIT HEATER TO PREVENT SIMULTANEOUSOPERATION. 5° DEADBAND MINIMUM.

DOOR OPEN SENSOR

DIFFUSER LOCATION SHOWN IS APPROXIMATE. FOR EXACTDISPLACEMENT DIFFUSER LOCATIONS, REFERENCE A11.XSERIES ARCHITECTURAL INTERIOR ELEVATIONS.

2

3

4

5

6

7

8

9

10

11

12

13

14

15

Arch

itect

ure

Eng

inee

ring

Pla

nnin

g In

terio

rs

©

, DLR

Gro

up in

c., a

Was

hing

ton

corp

orat

ion,

ALL

RIG

HTS

RE

SER

VED

KEY PLAN

D

C

B

A

NORTH

BEN

JAM

IN T

ALPO

S

Revis

i ons

7/20

/201

2 3:

43:2

2 PM

C:\U

sers

\dlu

zius

\Doc

umen

ts\^

Rev

it\73

-101

22-0

0\73

-101

22-0

0_lo

cal(d

luzi

us)_

MEP

_201

1.rv

t

73-1

0122

-00

07/2

3/20

12AL

EXAN

DER

GR

AHAM

BEL

L EL

EMEN

TAR

Y SC

HO

OL

CONFORMEDSET

FIR

ST L

EVEL

HVA

C P

LAN

- AR

EA A

/BM

1.1

2012

Lake

Was

hing

ton

Scho

ol D

istri

ct

SCALE: 1/8" = 1'-0"FIRST LEVEL HVAC PLAN - AREA A/B

NORTH