Current Transformer Oil Impregnated Paper Current Transformer (Dead Tank) Features Sealed oil-filled capacitor type structure with metallic expansion bellows; With more efficient sealing method, which slows the eging process of the gasket seal and extends the product life; Uniform electric field, low partial discharge and good usability; Large value of dynamic current and short-tim thermal current; Available for more secondary tapping, which can satisfy the needs of various mea surement and protection; Expansion bellows: stainless steel shell, oil tank coated with a special paint (which is water-proof, mould-proof and salt-proof); Maintenance-free. Specifications Nominal Voltage of System Kv Highest. Voltage for Equipment kV Lin Rated Primary Current A Short-time Thermal Current KA/s Rated Dynamic Current kA Rated insulation Level kV Dielectric Dissipation Factor Creepage Distance of External Insulation mm / Oil Weight/Gross Weight kg Um Partial Discharge under UmpC RIV uV Applicable Altitude Range m Rated Secondary Current A Amplifying Current Factor Rated Frequency Hz Measurement Accuracy Class Protection Accuracy Class Windings Combination Rated Burden and Instrument Security Factor of Measuring Class Rated Burden and Accuracy Limit Factor of Protective Class TPY Performance Parameter of TPY Class 5 250 3500 1, 5 120-200 I1n 50 0.1, 0.2S, 0.5S, 0.2, 0.5 TPS, TPY, 5P, 10P, 5PR, 10PR, PX 0.2S, 0.5, 5P, 5PR, TPY, TPY 10-80VA, Fs<5 10-80VA, SP15-5P40/10P15-10P40 Kssc=10~20, T1=0.1s, C-0.1s-0-0.5s-C-0.1s-0 35 40.5 10-2000, 2 50~2 600 100 I1n/1~50/3 250 I1n~125 40.5/95/200 0.018 1012.5, 1255.5 32~46/162~230 110 126 2 50~2 1200, 150~2500 45~50/3 115~125 126/230/550 0.003 3150, 3906 130/540( 2 600A), 150~570 220 252 2 1250~2 1500, 1250~3000A 50~63/3 125~160 252/460/1050 0.003 6300, 7812 580/1680 Structure LB7-220W LB7-110W LB6-35W 2390 20 1905 15 P2 520 P1 475 475 4 18 t20 100 50 25 50 25 P2 P1 3620 20 3030 20 850 120 610 450 4 25 4 18 t20 100 50 25 50 25 1875 20 1430 15 258 258 510 4 14 4 18 100 50 50 25 25 t20 4 18 04 ABB ABB Instrument Transformer Product Manuals 05
6
Embed
Current Transformer Oil Impregnated Paper Current ...sme-power.com/pic/other/2014-11-05-14-43-457.pdf · Current Transformer Oil Impregnated Paper Current Transformer (Dead Tank)
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Current Transformer Oil Impregnated Paper Current Transformer (Dead Tank)
Features
Sealed oil-filled capacitor type structure with metallic expansion
bellows;
With more efficient sealing method, which slows the eging
process of the gasket seal and extends the product life;
Uniform electric field, low partial discharge and good usability;
Large value of dynamic current and short-tim thermal current;
Available for more secondary tapping, which can satisfy the
needs of various mea surement and protection;
Expansion bellows: stainless steel shell, oil tank coated with a
special paint (which is water-proof, mould-proof and salt-proof);
Maintenance-free.
Specifications
Nominal Voltage of System Kv
Highest. Voltage for Equipment kV
Lin Rated Primary Current A
Short-time Thermal Current KA/s
Rated Dynamic Current kA
Rated insulation Level kV
Dielectric Dissipation Factor
Creepage Distance of External Insulation mm
/ Oil Weight/Gross Weight kg
Um Partial Discharge under UmpC
RIV uV
Applicable Altitude Range m
Rated Secondary Current A
Amplifying Current Factor
Rated Frequency Hz
Measurement Accuracy Class
Protection Accuracy Class
Windings Combination
Rated Burden and Instrument Security Factor of Measuring Class
Rated Burden and Accuracy Limit Factor of Protective Class