Page 1
NAMUR PS2-11P-N/SX PS4-11P-N/SX
( DIN - 19234 )
Picture 1 1
Nominal distance 2 mm 4 mm
Operating sensor distance 0 … 1.62 mm 0 … 3.24 mm
Assembly built-in not built-in
Hysteresis 5 % 5 %
Repeatability < 0.01 mm < 0.01 mm
Standard target 11 x 11 mm 11 x 11 mm
Supply voltage 7 to 12 Vdc 7 to 12 Vdc
Nominal voltage 8 Vdc ± 5 % 8 Vdc ± 5 %
Ripple 5 % 5 %
Voltage with the sensor activated £ 1 mA £ 1 mA
Voltage with the sensor disabled ³ 3 mA ³ 3 mA
Max. wiring resistance 100 W 100 W
Maximum frequency 800 Hz 400 Hz
Signalling without led without led
Operating temperature - 25 oC to + 100 oC - 25 oC to + 70 oC
Protection rate IP 67 IP 67
Connection 2-wire cable 2-wire cable
Tube length 32 mm 32 mm
Cable options PVC 6 m PVC 6 m
Casing thermoplastic (PBT/ VO) thermoplastic (PBT/ VO)
Cable Color
MR brown
AZ blue
1-4.1
MechanicalDimensions
COMPLEMENTARY LINE
Output ConfigurationIEC 947-5-2 / IEC 1000-4-2.3.4.5
Inductive Proximity Sensors
Namur DirectCurrent
ØØ1111
3322
F11
Page 2
NPN PS2-11P-A/SZ PS4-11P-A/SZ
PNP PS2-11P-A2/SZ PS4-11P-A2/SZ
Picture 1 1
Nominal distance 2 mm 4 mm
Operating sensor distance 0 … 1.62 mm 0 … 3.24 mm
Assembly built-in not built-in
Hysteresis 5 % 5 %
Repeatability < 0.01 mm < 0.01 mm
Standard target 11 x 11 mm 11 x 11 mm
Supply voltage 10 to 30 Vdc 10 to 30 Vdc
Ripple + 10 % + 10 %
Consumption current < 10 mA < 10 mA
Maximum switching current 200 mA ± 15 % 200 mA ± 15 %
Output protection short-circuit and inversion short-circuit and inversion
Transient Protection 1 kV / 10ms / 10kW 1 kV / 10ms / 10kW
Sensor voltage drop < 2 V < 2 V
Maximum frequency 800 Hz 400 Hz
Signalling back led back led
Operating temperature - 25 °C to + 70 oC - 25 °C to + 70 °C
Protection rate IP 67 IP 67
Connection cable 4 wires cable 4 wires
Cable options PVC 6 m or polyurethane 2 m PVC 6 m or polyurethane 2 m
Tube length 71 71
Casing thermoplastic (PBT/ VO) thermoplastic (PBT/ VO)
Cable Color
MR brown
AZ blue
PR black
BR white
1-4.2
COMPLEMENTARY LINE
Output ConfigurationIEC 947-5-2 / IEC 1000-4-2.3.4.5
Mechanical
Inductive Proximity Sensors
Direct Current4 wires
1100 aa 3300VVcccc
MMRR((11))NNPPNN
NA+NFNA+NF
-- AA
BBRR((22))
PPRR((44))
AAZZ((33)) --
++
F11
71
Page 3
NAMUR PS4-16I-N/SX NPN PS4-16I-A/SZ PS5-16P-A/SZ
( DIN - 19234 ) PNP PS4-16I-A2/SZ PS5-16P-A2/SZ
Picture 1 Picture 2 3
Nominal distance 4 mm Nominal distance 4 mm 5 mm
Operating sensor distance 0 … 3. 24 mm Operating sensor distance 0 … 3.24 mm 0 … 4.05 mm
Assembly built-in Assembly built-in built-in
Hysteresis 5 % Hysteresis 5 % 5 %
Repeatability < 0. 01 mm Repeatability < 0.01 mm < 0.01 mm
Standard target 16 x 16 mm Standard target 16 x 16 mm 16 x 16 mm
Supply voltage 7 to 12 Vdc Supply voltage 10 to 30 Vdc 10 to 30 Vdc
Nominal voltage 8 Vdc ± 5 % Ripple ± 10 % ± 10 %
Ripple 5 % Consumption current < 10 mA < 10 mA
Voltage with the sensor activated £ 1 mA Maximum switching current 200 mA ± 15 % 200 mA ± 15 %
Voltage with the sensor disabled ³ 3 mA Output protection short-circuit and inversion short-circuit and inversion
Max. wiring resistance 100 W Transient Protection 1kV/ 10 ms / 10kW 1kV/ 10 ms / 10kW
Maximum frequency 500 Hz Sensor voltage drop £`2V £`2V
Signalling without led Maximum frequency 500 Hz 500 Hz
Operating temperature - 25 oC to + 100 oC Signalling back led back led
Protection rate IP 67 Operating temperature - 25ºC to +70ºC -25º C to + 70ºC
Connection 2-wire cable Protection rate IP 67 IP 67
Tube length 50 mm Connection cable 4 wires cable 4 wires
Cable options PVC 6 m Tube length 50 mm 61 mm
Casing nickelled brass Cable options PVC 6 m or polyurethane 2 m PVC 6 m or polyurethane 2 m
Casing Options nickelled brass thermoplastic (PBT/VO)
Cable Color
MR brown
AZ blue
PR black
BR white
1-4.3
MechanicalDimensions
COMPLEMENTARY LINE
Output ConfigurationIEC 947-5-2 / IEC 1000-4-2.3.4.5
Inductive Proximity Sensors
F 16
Direct CurrentNamur
SSEEXXTT.. 2222xx44
MM1166xx11
5050
Ø
Ø
1
1
6
6
Ø
Ø
3
3
(
(
6
6
x
x
)
)
2
2
6
6
3
3
3
3
1
1
5
5
L
L
E
E
D
D
61
Direct Current4 wires
F 16
1100 aa 3300VVcccc
MMRR((11))NNPPNN
NA+NFNA+NF
-- AA
BBRR((22))
PPRR((44))
AAZZ((33)) --
++
Page 4
Alternating Current2 wires
NA PS4-16I-WA/SY PS5-16P-WA/SY
NF PS4-16I-WF/SY PS5-16P-WF/SY
Picture 1 2
Nominal distance 4 mm 5 mm
Operating sensor distance 0 … 3.24 mm 0 … 4.05 mm
Assembly built-in built-in
Hysteresis 5 % 5 %
Repeatability < 0.01 mm < 0.01 mm
Standard target 16 x 16 mm 16 x 16 mm
Supply voltage 20 to 250 Vac 20 to 250 Vac
Maximum switching current 500 mA 500 mA
Transient Protection 1 kV / 10 ms / 10kW 1 kV / 10 ms / 10kW
Impulse Current 4 A 4 A
Load residual voltage 3 mA 3 mA
Load minimum voltage 5 mA 5 mA
Sensor voltage drop£ 5V < 5 V
Maximum frequency 10 Hz 10 Hz
Signalling back led back led
Operating temperature -25°C to + 70°C - 25 oC to + 70 oC
Protection rate IP 67 IP 67
Connection 2-wire cable 2-wire cable
Tube length 50 mm 61 mm
Cable options PVC 6 m or polyurethane 2 m PVC 6 m or polyurethane 2 m
Casing nickelled brass thermoplastic (PBT/ VO)
Cable Color
MR brown
AZ blue
VD / AM grounding
1-4.4
COMPLEMENTARY LINE
Output ConfigurationIEC 947-5-2 / IEC 1000-4-2.3.4.5
Mechanical
Inductive Proximity Sensors
2200 aa 225500VVccaa
WWFF
AAZZ((22))
MMRR((11))
WWAAMMRR((33))
AAZZ((44))
2200 aa 225500VVccaa
SSEEXXTT.. 2222xx44
MM1166xx11
LLEEDD
50
ØØ1166
ØØ33((66xx))
22663333
1155
LLEEDD
61
F 16
Page 5
NA PS5-18P-WA/SY PS8-18P-WA/SY
NF PS5-18P-WF/SY PS8-18P-WF/SY
Picture 1 2
Nominal distance 5 mm 8 mm
Operating sensor distance 0 … 4.05 mm 0 … 6.48 mm
Assembly built-in not built-in
Hysteresis 5 % 5 %
Repeatability < 0.01 mm < 0.01 mm
Standard target 18 x 18 mm 24 x 24 mm
Supply voltage 20 to 250 Vac (50 - 60 Hz) 20 to 250 Vac (50 - 60Hz)
Maximum switching current 500 mA 500 mA
Transient Protection 1 kV / 10 ms / 10kW 1 kV / 10 ms / 10kW
Impulse Current 4 A 4 A
Load residual voltage 3 mA 3 mA
Load minimum voltage 5 mA 5 mA
Sensor voltage drop£ 5 V £ 5 V
Maximum frequency 10 Hz 10 Hz
Signalling back led back led
Operating temperature - 25 oC to + 70 oC - 25 oC to + 70 oC
Protection rate IP 67 IP 67
Connection 2-wire cable 2-wire cable
Tube length 61 mm 61 mm
Cable options PVC 6 m or polyurethane 2 m PVC 6 m or polyurethane 2 m
Casing thermoplastic (PBT/ VO) thermoplastic (PBT/ VO)
Cable Color
MR brown
AZ blue
1-4.5
MechanicalDimensions
COMPLEMENTARY LINE
Output ConfigurationIEC 947-5-2 / IEC 1000-4-2.3.4.5
Inductive Proximity Sensors
Alternating Current2 wires
Ø18
WWAAMMRR((33))
AAZZ((44))
2200 aa 225500VVccaa
2
2
0
0
a
a
2
2
5
5
0
0
V
V
c
c
a
a
W
W
F
F
A
A
Z
Z
(
(
2
2
)
)
M
M
R
R
(
(
1
1
)
)
Ø
Ø
1
1
8
8
Ø
Ø
3
3
(
(
6
6
x
x
)
)
3
3
3
3
2
2
6
6
1
1
5
5
L
L
E
E
D
D
61
Page 6
NPN PS15-32P-A/SZ NAMUR PS15-32P-N/SX
PNP PS15-32P-A2/SZ (DIN - 19234)
Picture 3 Picture 2
Nominal distance 15 mm Nominal distance 15 mm
Operating sensor distance 0 … 12.15 mm Operating sensor distance 0 … 12.15 mm
Assembly not built-in Assembly not built-in
Hysteresis 5 % Hysteresis 5 %
Repeatability < 0.01 mm Repeatability < 0.01 mm
Standard target 45 x 45 mm Standard target 45 x 45 mm
Supply voltage 10 to 30 Vdc Supply voltage 7 to 12 Vdc
Ripple ± 10 % Nominal voltage 8 Vdc ± 5%
Consumption current < 10 mA Ripple 5 %
Maximum switching current 200 mA ± 15 % Voltage with the sensor activated £ 1 mA
Output protection short-circuit and inversion Voltage with the sensor disabled ³ 3 mA
Transient Protection 1 kV / 10ms / 10kW Max. wiring resistance 100 W
Sensor voltage drop £ 2 V Maximum frequency 100 Hz
Maximum frequency 100 Hz Signalling without led
Signalling back led Operating temperature - 25º C to + 100 º C
Operating temperature - 25 oC to + 70 oC Protection rate IP 67
Protection rate IP 67 Connection 2-wire cable
Connection cable 4 wires Tube length 107 mm
Tube length 107 mm Cable options PVC 6 m
Cable options PVC 6 m or polyurethane 2 m Casing thermoplastic (PBT/VO)
Casing Options thermoplastic (PBT/ VO)
Cable Color
MR brown
AZ blue
PR black
BR white
1-4.6
COMPLEMENTARY LINE
Output ConfigurationIEC 947-5-2 / IEC 1000-4-2.3.4.5
Mechanical
Inductive Proximity Sensors
1100 aa 3300VVcccc
MMRR((11))NNPPNN
NA+NFNA+NF
-- AA
BBRR((22))
PPRR((44))
AAZZ((33)) --
++
SSEEXXTT.. 2222xx44
MM1166xx11
50 107
89
F 32
Direct Current4 wires
F 32
Direct Current4 wires
Page 7
NA PS15-32P-W3A/SY PS15-32P-W4/S2X NA PS15-32-WA/SY
NF PS15-32P-W3F/SY NF PS15-32P-WF/SY
Picture 1 2 Picture 3
Nominal distance 15 mm 15 mm Nominal distance 15 mm
Operating sensor distance 0 … 12.15 mm 0 … 12.15 mm Operating sensor distance 0 … 12.15 mm
Assembly not built-in not built-in Assembly not built-in
Hysteresis 5 % 5 % Hysteresis 5 %
Repeatability < 0.01 mm < 0.01 mm Repeatability < 0.01 mm
Standard target 45 x 45 mm 45 x 45 mm Standard target 45 x 45 mm
Supply voltage 20 to 250 Vac (50 - 60 Hz) 90 to 250 Vac (50 - 60 Hz) Supply voltage 20 to 250 Vac
Maximum switching current 500 mA 500 mA Maximum switching current 500 mA
Consumption current £ 10 mA £ 10 mA Transient Protection 1 kV / 10 ms / 10 kW
Impulse Current 4 A 4 A Impulse Current 4 A
Transient Protection 1 kV / 10 ms / 10kW 1 kV / 10 ms / 10kW Load residual voltage 3 mA
Sensor voltage drop £ 1.5 V £ 1.5 V Load minimum voltage 5 mA
Maximum frequency 10 Hz 10 Hz Sensor voltage drop £ 5 V
Signalling back led back led Maximum frequency 10 Hz
Operating temperature - 25 oC to + 70 oC - 25 oC to + 70 oC Signalling back led
Protection rate IP 67 IP 67 Operating temperature - 25º C to + 70º C
Connection cable 3 wires cable 4 wires Protection rate IP 67
Tube length 107 mm 107 mm Connection 2-wire cable
Cable options PVC 6 m or polyurethane 2 m PVC 6 m or polyurethane 2 m Tube length 107 mm
Casing thermoplastic (PBT/ VO) thermoplastic (PBT/ VO) Cable options PVC 6 m or polyurethane 2 m
Casing thermoplastic (PBT/VO)
Cable Color
MR brown
AZ blue
PR black
BR white
1-4.7
MechanicalDimensions
COMPLEMENTARY LINE
Output ConfigurationIEC 947-5-2 / IEC 1000-4-2.3.4.5
Inductive Proximity Sensors
Alternating Current3 wires / 4 wires
F 32
Alternating Current2 wires
WWAAMMRR((33))
AAZZ((44))
2200 aa 225500VVccaa
W
W
3
3
F
F
N
N
F
F
M
M
R
R
(
(
1
1
)
)
P
P
R
R
(
(
4
4
)
)
A
A
Z
Z
(
(
3
3
)
)
2
2
0
0
a
a
2
2
5
5
0
0
V
V
c
c
a
a
W
W
3
3
A
A
M
M
R
R
(
(
1
1
)
)
A
A
Z
Z
(
(
3
3
)
)
P
P
R
R
(
(
4
4
)
)
2
2
0
0
a
a
2
2
5
5
0
0
V
V
c
c
a
a
N
N
A
A
P
P
R
R
(
(
4
4
)
)
B
B
R
R
(
(
2
2
)
)
A
A
Z
Z
(
(
3
3
)
)
M
M
R
R
(
(
1
1
)
)
9
9
0
0
a
a
2
2
5
5
0
0
V
V
c
c
a
a
-
-
+
+
W
W
4
4
107
89
2
2
0
0
a
a
2
2
5
5
0
0
V
V
c
c
a
a
W
W
F
F
A
A
Z
Z
(
(
2
2
)
)
M
M
R
R
(
(
1
1
)
)
F 32
Page 8
NAMUR PS2-14I-N/SX PS4-14I-N/SX
( DIN - 19234 )
Picture 1 2
Nominal distance 2 mm 4 mm
Operating sensor distance 0 … 1.62 mm 0 … 3.24 mm
Assembly built-in not built-in
Hysteresis 5 % 5 %
Repeatability < 0.01 mm < 0.01 mm
Standard target 14 x 14 mm 14 x 14 mm
Supply voltage 7 to 12 Vdc 7 to 12 Vdc
Nominal voltage 8 Vdc ± 5 % 8 Vdc ± 5 %
Ripple + 5 % + 5 %
Voltage with the sensor activated £ 1 mA £ 1 mA
Voltage with the sensor disabled ³ 3 mA ³ 3 mA
Max. wiring resistance 100 W 100 W
Maximum frequency 800 Hz 400 Hz
Signalling without led without led
Operating temperature - 25 oC to + 100 oC - 25 oC to + 100 oC
Protection rate IP 67 IP 67
Connection 2-wire cable 2-wire cable
Tube length 32 mm 32 mm
Cable options PVC 6 m PVC 6 m
Casing nickelled brass nickelled brass
Cable Color
MR brown
AZ blue
1-4.8
COMPLEMENTARY LINE
Output ConfigurationIEC 947-5-2 / IEC 1000-4-2.3.4.5
Mechanical
Inductive Proximity Sensors
M14
Direct CurrentNamur
SSEEXXTT.. 1199xx44MM
1144xx11
32 32
Page 9
NPN PS2-14I-A/SZ PS4-14I-A/SZ
PNP PS2-14I-A2/SZ PS4-14I-A2/SZ
Picture 1 2
Nominal distance 2 mm 4 mm
Operating sensor distance 0 … 1.62 0 … 3.24 mm
Assembly built-in not built-in
Hysteresis 5 % 5 %
Repeatability < 0.01 mm < 0.01 mm
Standard target 14 x 14 mm 14 x 14 mm
Supply voltage 10 to 30 Vdc 10 to 30 Vdc
Ripple ± 10 % ± 10 %
Consumption current < 10 mA < 10 mA
Maximum switching current 200 mA ± 15 % 200 mA ± 15 %
Output protection short-circuit and inversion short-circuit and inversion
Transient Protection 1 kV / 10 ms / 10kW 1 kV / 10 ms / 10kW
Sensor voltage drop £ 2 V £ 2 V
Maximum frequency 800 Hz 200 Hz
Signalling back led back led
Operating temperature - 25°C to + 70°C - 25 oC to + 70 oC
Protection rate IP 67 IP 67
Connection cable 4 wires cable 4 wires
Tube length 51 mm 51 mm
Cable options PVC 6 m or polyurethane 2 m PVC 6 m or polyurethane 2 m
Casing nickelled brass nickelled brass
Cable Color
MR brown
AZ blue
PR black
BR white
1-4.9
MechanicalDimensions
COMPLEMENTARY LINE
Output ConfigurationIEC 947-5-2 / IEC 1000-4-2.3.4.5
Inductive Proximity Sensors
M14
Direct Current4 wires
1100 aa 3300VVcccc
MMRR((11))NNPPNN
NA+NFNA+NF
-- AA
BBRR((22))
PPRR((44))
AAZZ((33)) --
++
M
M
1
1
4
4
x
x
1
1
S
S
E
E
X
X
T
T
.
.
1
1
9
9
x
x
4
4
L
L
E
E
D
D
51
32
Page 10
NPN PS6-20I-A/SZ NA PS6-20I-WA/SY
PNP PS6-20I-A2/SZ NF PS6-20I-WF/SY
Picture 1 Picture 2
Nominal distance 6 mm Nominal distance 6 mm
Operating sensor distance 0 … 4.86 mm Operating sensor distance 0 … 4.86 mm
Assembly built-in Assembly built-in
Hysteresis 5 % Hysteresis 5%
Repeatability < 0.01 mm Repeatability < 0.01 mm
Standard target 20 x 20 mm Standard target 20 x 20 mm
Supply voltage 10 to 30 Vdc Supply voltage 20 to 250 Vac (50 - 60 Hz)
Ripple ± 10 % Max. switching currento 500 mA
Consumption current < 10 mA Transient Protection 1 kV / 10 ms / 10W
Maximum switching current 200 mA ±15 % Impulse Current 4 A
Output protection short-circuit and inversion Load residual voltage 3 mA
Transient Protection 1 kV / 10 ms / 10kW Load minimum voltage 5 mA
Sensor voltage drop £ 2 V Sensor voltage drop £ 5 V
Maximum frequency 200 Hz Maximum frequency 10 Hz
Signalling back led Signalling back led
Operating temperature - 25 ºC to + 70 ºC Operating temperature - 25ºC to +70ºC
Protection rate IP 67 Protection rate IP 67
Connection cable Connection cable
Tube length 50 mm Tube length 50 mm
Cable options PVC 6 m or polyurethane 2 m Cable options PVC 6 m or polyurethane 2 m
Casing nickelled brass Casing nickelled brass
Cable Color
MR brown
AZ blue
PR black
BR white
1-4.10
COMPLEMENTARY LINE
Output ConfigurationIEC 947-5-2 / IEC 1000-4-2.3.4.5
Mechanical
Inductive Proximity Sensors
Corrente Continua4 wires
M20
1100 aa 3300VVcccc
MMRR((11))NNPPNN
NA+NFNA+NF
-- AA
BBRR((22))
PPRR((44))
AAZZ((33)) --
++
S
S
E
E
X
X
T
T
.
.
2
2
5
5
x
x
4
4
M
M
2
2
0
0
x
x
1
1
L
L
E
E
D
D
50
Alternating Current2 wires
M20
SSEEXXTT.. 2255xx44
MM2200xx11
LLEEDD
50
Page 11
NPN PS8-22I-A/SZ NA PS8-22I-WA/SY
PNP PS8-22I-A2/SZ NF PS8-22I-WF/SY
Picture 1 Picture 2
Nominal distance 6 mm Nominal distance 8 mm
Operating sensor distance 0 … 6.48 mm Operating sensor distance 0 … 6.48 mm
Assembly built-in Assembly built-in
Hysteresis 5 % Hysteresis 5 %
Repeatability < 0.01 mm Repeatability < 0.01 mm
Standard target 20 x 20 mm Standard target 24 x 24 mm
Supply voltage 10 to 30 Vdc Supply voltage 20 to 250 Vac (50 - 60 Hz)
Ripple ± 10% Max. switching current 500 mA
Consumption current < 10 mA Transient Protection 1 kV / 10 ms / 10kW
Maximum switching current 200 mA ±15% Impulse Current 4 A
Output protection curto-circuto e inversão Residual voltage on load 3 mA
Protection against transient 1 kV/ 10 ms / 10 W Load minimum voltage 5 mA
Sensor voltage drop £ 2 V Sensor voltage drop £ 5 V
Maximum frequency 200 Hz Maximum frequency 10 Hz
Signalling back led Signalling back led
Operating temperature - 25ºC to + 70 ºC Operating temperature - 25 ºC to + 70 ºC
Protection rate IP 67 Grau de proteção IP 67
Connection cable Connection cable
Tube length 50 mm Tube length 50 mm
Cable options PVC 6 m or polyurethane 2 m Cable options PVC 6 m or polyurethane 2 m
Casing nickelled brass Casing nickelled brass
Cable Color
MR brown
AZ blue
VD / AM grounding
1-4.11
MechanicalDimensions
COMPLEMENTARY LINE
Output ConfigurationIEC 947-5-2 / IEC 1000-4-2.3.4.5
Inductive Proximity Sensors
Alternating Current2 wires
M22
SSEEXXTT.. 2255xx44
MM2200xx11
LLEEDD
50
M22x1,5
M22x1,5
ØØ1199
22
SSEEXXTT.. 2299xx55
LLEEDD
50
S
S
E
E
X
X
T
T
.
.
2
2
2
2
x
x
4
4
M
M
1
1
6
6
x
x
1
1
L
L
E
E
D
D
50
Ø
Ø
M51x1,5
M51x1,5
SEXT. 64x7
SEXT. 64x7
1111
6565
8787
ØØ1313
ØØ4848
2222
Alternating Current2 wires
M22
Page 12
NA PS6-20I-W3A/SY PS8-22I-W3A/SY
NF PS6-20I-W3F/SY PS8-22I-W3F/SY
Picture 1 2
Nominal distance 6 mm 8 mm
Operating sensor distance 0 … 4.86 mm 0 … 6.48 mm
Assembly built-in built-in
Hysteresis 5 % 5 %
Repeatability < 0.01 mm < 0.01 mm
Standard target 20 x 20 mm 24 x 24 mm
Supply voltage 20 to 250 Vac (50 - 60 Hz) 20 to 250 Vac (50 - 60 Hz)
Maximum switching current 500 mA 500 mA
Consumption current £ 10 mA £ 10 mA
Impulse Current 4 A 4 A
Transient Protection 1 kV / 10 ms / 10kW 1 kV / 10 ms / 10kW
Sensor voltage drop £ 1.5 V £ 1.5 V
Maximum frequency 10Hz 10 Hz
Signalling back led back led
Operating temperature - 25 oC to + 70 oC - 25 oC to + 70 oC
Protection rate IP 67 IP 67
Connection cable 3 wires cable 3 wires
Tube length 50 mm 50 mm
Cable options PVC 6 m or polyurethane 2 m PVC 6 m or polyurethane 2 m
Casing nickelled brass nickelled brass
Cable Color
MR brown
AZ blue
PR black
VD / AM grounding
1-4.12
COMPLEMENTARY LINE
Output ConfigurationIEC 947-5-2 / IEC 1000-4-2.3.4.5
Mechanical
Inductive Proximity Sensors
Alternating Current3 wires
M20 / M22
WW33AA
VVDD//AAMM((55))
MMRR((11))
AAZZ((33))
PPRR((44))2200 aa 225500VVccaa
NNAA
S
S
E
E
X
X
T
T
.
.
2
2
5
5
x
x
4
4
M
M
2
2
0
0
x
x
1
1
L
L
E
E
D
D
50
M22x1,5
M22x1,5
ØØ1199
22
SSEEXXTT.. 2299xx55
LLEEDD
50
Page 13
NPN PS10-25I-A/SZ PS12-25I-A/SZ
PNP PS10-25I-A2/SZ PS12-25I-A2/SZ
Picture 1 2
Nominal distance 10 mm 12 mm
Operating sensor distance 0 … 8.1 mm 0 … 9.72 mm
Assembly built-in not built-in
Hysteresis 5 % 5 %
Repeatability < 0.01 mm < 0.01 mm
Standard target 25 x 25 mm 36 x 36 mm
Supply voltage 10 to 30 Vdc 10 to 30 Vdc
Ripple £ 10 % £ 10 %
Consumption current < 10 mA < 10 mA
Max. switching current 200 mA ± 15 % 200 mA ± 15 %
Output protection short-circuit and inversion short-circuit and inversion
Transient Protection 1 kV / 10 ms / 10kW 1 kV / 10 ms / 10kW
Sensor voltage drop £ 2 V £ 2V
Maximum frequency 300 Hz 100 Hz
Signalling back led back led
Operating temperature - 25 ºC to + 70 ºC - 25 ºC to + 70 ºC
Protection rate IP 67 IP 67
Connection cable cable
Tube length 50 mm 50 mm
Cable options PVC 6 m or polyurethane 2 m PVC 6 m or polyurethane 2 m
Casing nickelled brass nickelled brass
Cable Color
MR brown
AZ blue
PR black
BR white
1-4.13
MechanicalDimensions
COMPLEMENTARY LINE
Output ConfigurationIEC 947-5-2 / IEC 1000-4-2.3.4.5
Inductive Proximity Sensors
MM2255xx11
SSEEXXTT.. 3322xx55
LLEEDD
50
1122
MM2255xx11
ØØ2244
SSEEXXTT.. 3322xx55
LLEEDD
50
Direct Current4 wires
M25
1100 aa 3300VVcccc
MMRR((11))NNPPNN
NA+NFNA+NF
-- AA
BBRR((22))
PPRR((44))
AAZZ((33)) --
++
Page 14
NA PS10-25I-WA/SY PS12-25I-WA/SY
NF PS10-25I-WF/SY PS12-25I-WF/SY
Picture 1 2
Nominal distance 10 mm 12 mm
Operating sensor distance 0 … 8.1 mm 0 … 9.72 mm
Assembly built-in not built-in
Hysteresis 5 % 5 %
Repeatability < 0.01 mm < 0.01 mm
Standard target 25 x 25 mm 36 x 36 mm
Supply voltage 20 to 250 Vac (50 - 60 Hz) 20 to 250 Vac (50 - 60 Hz)
Maximum switching current 500 mA 500 mA
Transient Protection 1 kV / 10 ms / 10kW 1 kV / 10 ms / 10kW
Impulse Current 4 A 4 A
Residual voltage on load 3 mA 3 mA
Minimum voltage on load 5 mA 5 mA
Sensor voltage drop< 5 V < 5 V
Maximum frequency 10 Hz 10 Hz
Signalling back led back led
Operating temperature - 25 °C to + 70°C - 25°C to + 70°C
Protection rate IP 67 IP 67
Connection cable cable
Tube length 50 mm 50 mm
Cable options PVC 6 m or polyurethane 2 m PVC 6 m or polyurethane 2 m
Casing nickelled brass nickelled brass
Cable Color
MR brown
AZ blue
VD / AM grounding
1-4.14
COMPLEMENTARY LINE
Output ConfigurationIEC 947-5-2 / IEC 1000-4-2.3.4.5
Mechanical
Inductive Proximity Sensors
MM2255xx11
SSEEXXTT.. 3322xx55
LLEEDD
50
1122
MM2255xx11
ØØ2244
SSEEXXTT.. 3322xx55
LLEEDD
50
Alternating Current2 wires
M25
2200 aa 225500VVccaa
NNFF
WWFF
VVDD//AAMM((55))
AAZZ((22))
MMRR((11))
2
2
0
0
a
a
2
2
5
5
0
0
V
V
c
c
a
a
N
N
F
F
W
W
F
F
V
V
D
D
/
/
A
A
M
M
(
(
5
5
)
)
A
A
Z
Z
(
(
2
2
)
)
M
M
R
R
(
(
1
1
)
)
Page 15
NA PS10-25I-W3A/SY PS12-25I-W3A/SY PS10-25H-W4/S2X PS12-25H-W4/S2X
NF PS10-25I-W3F/SY PS12-25I-W3F/SY
Picture 1 2 1 2
Nominal distance 10 mm 12 mm 10 mm 12 mm
Operating sensor distance 0 … 8.1 mm 0 … 9.72 mm 0 … 8.1 mm 0 … 9.72 mm
Assembly built-in not built-in built-in not built-in
Hysteresis 5 % 5 % 5 % 5 %
Repeatability < 0.01 mm < 0.01 mm < 0.01 mm < 0.01 mm
Standard target 25 x 25 mm 36 x 36 mm 25 x 25 mm 36 x 36 mm
Supply voltage 20 to 250 Vac (50 - 60 Hz) 20 to 250 Vac (50 - 60 Hz) 90 to 250 Vac (50 - 60 Hz) 90 to 250 Vac (50 - 60 Hz)
Maximum switching current 500 mA 500 mA 500 mA 500 mA
Consumption current £10 mA £10 mA £10 mA £10 mA
Impulse Current 4 A 4 A 4 A 4 A
Transient Protection 1 kV / 10 ms / 10kW 1 kV / 10 ms / 10kW 1 kV / 10 ms / 10kW 1 kV / 10 ms / 10kW
Sensor voltage drop £ 1.5 V £ 1.5 V £ 1.5 V £ 1.5 V
Maximum frequency 10 Hz 10 Hz 10 Hz 10 Hz
Signalling back led back led back led back led
Operating temperature - 25 ºC to + 70 ºC - 25 ºC to + 70 ºC - 25 ºC to + 70 ºC - 25 ºC to + 70 ºC
Protection rate IP 67 IP 67 IP 67 IP 67
Connection cable 3 wires cable 3 wires cable 4 wires cable 4 wires
Tube length 50 mm 50 mm 50 mm 50 mm
Cable options PVC 6 m or polyurethane 2 m PVC 6 m or polyurethane 2 m PVC 6 m or polyurethane 2 m PVC 6 m or polyurethane 2 m
Casing nickelled brass nickelled brass nickelled brass nickelled brass
Cable Color
MR brown
AZ blue
PR black
BR white
VD / AM grounding
1-4.15
MechanicalDimensions
COMPLEMENTARY LINE
Output ConfigurationIEC 947-5-2 / IEC 1000-4-2.3.4.5
Inductive Proximity Sensors
Alternating Current3 wires / 4 wires
M25
PPRR((44))
BBRR((22))
AAZZ((33))
MMRR((11))
9900 aa 225500VVccaa
--
++WW44
1
1
2
2
M
M
2
2
5
5
x
x
1
1
Ø
Ø
2
2
4
4
S
S
E
E
X
X
T
T
.
.
3
3
2
2
x
x
5
5
L
L
E
E
D
D
50
M
M
2
2
5
5
x
x
1
1
S
S
E
E
X
X
T
T
.
.
3
3
2
2
x
x
5
5
L
L
E
E
D
D
50
W
W
3
3
A
A
V
V
D
D
/
/
A
A
M
M
(
(
5
5
)
)
M
M
R
R
(
(
1
1
)
)
A
A
Z
Z
(
(
3
3
)
)
P
P
R
R
(
(
4
4
)
)
2
2
0
0
a
a
2
2
5
5
0
0
V
V
c
c
a
a
N
N
A
A
Page 16
NAMUR PS12-36IG-N/SX PS17-36IG-N/SX
( DIN - 19234 )
Picture 1 2
Nominal distance 12 mm 17 mm
Operating sensor distance 0 … 9.72 mm 0 … 13.77 mm
Assembly built-in not built-in
Hysteresis 5 % 5 %
Repeatability < 0.01 mm < 0.01 mm
Standard target 36 x 36 mm 51 x 51 mm
Supply voltage 7 to 12 Vdc 7 to 12 Vdc
Nominal voltage 8 Vdc ± 5 % 8 Vdc ± 5 %
Ripple 5 % 5 %
Voltage with the sensor activated £ 1 mA £ 1 mA
Voltage with the sensor disabled ³ 3 mA ³ 3 mA
Max. wiring resistance 100 W 100 W
Maximum frequency 100 Hz 100 Hz
Signalling without led without led
Operating temperature - 25 ºC to + 70 ºC - 25 ºC to + 70 ºC
Protection rate IP 67 IP 67
Connection cable cable
Tube length 50 mm 75 mm
Cable options PVC 6 m or polyurethane 2 m PVC 6 m or polyurethane 2 m
Casing nickelled brass nickelled brass
Cable Color
MR brown
AZ blue
1-4.16
COMPLEMENTARY LINE
Output ConfigurationIEC 947-5-2 / IEC 1000-4-2.3.4.5
Mechanical
Inductive Proximity Sensors
M36
Direct CurrentNamur
5050
SEXT. 42x5
SEXT. 42x5
M36x1,5
M36x1,5
M36x1,5
M36x1,5
ØØ
SEXT. 42x5
SEXT. 42x5
3232
1313
1515
5151
7575
ØØ
1111ØØ
Page 17
NPN PS12-36I-A/SZ PS17-36I-A/SZ
PNP PS12-36I-A2/SZ PS17-36I-A2/SZ
Picture 1 2
Nominal distance 12 mm 17 mm
Operating sensor distance 0 … 9.72 mm 0 … 13.77 mm
Assembly built-in not built-in
Hysteresis 5 % 5 %
Repeatability < 0.01 mm < 0.01 mm
Standard target 36 x 36 mm 51 x 51 mm
Supply voltage 10 to 30 Vdc 10 to 30 Vdc
Ripple ± 10 % ± 10%
Consumption current < 10 mA < 10 mA
Max. switching currento 200 mA ± 15 % 200 mA ± 15 %
Output protection short-circuit and inversion short-circuit and inversion
Transient Protection 1 kV / 10 ms / 10kW 1 kV / 10 ms / 10kW
Sensor voltage drop £ 2 V £ 2 V
Maximum frequency 100 Hz 100 Hz
Signalling back led back led
Operating temperature - 25 ºC to + 70 ºC - 25 ºC to + 70 ºC
Protection rate IP 67 IP 67
Connection cable cable
Tube length 50 mm 50 mm
Cable options PVC 6 m or polyurethane 2 m PVC 6 m or polyurethane 2 m
Casing nickelled brass nickelled brass
Cable Color
MR brown
AZ blue
PR black
BR white
1-4.17
MechanicalDimensions
COMPLEMENTARY LINE
Output ConfigurationIEC 947-5-2 / IEC 1000-4-2.3.4.5
Inductive Proximity Sensors
M36
Direct Current4 wires
1100 aa 3300VVcccc
MMRR((11))NNPPNN
NA+NFNA+NF
-- AA
BBRR((22))
PPRR((44))
AAZZ((33)) --
++
LEDLED
5050
SEXT. 42x5
SEXT. 42x5
M36x1,5
M36x1,5
Ø
Ø
3232
LEDLED
5050
SEXT. 42x5
SEXT. 42x5M
36x1,5
M36x1,5
1818
Page 18
NA PS12-36I-WA/SY PS17-36I-WA/SY
NF PS12-36I-WF/SY PS17-36I-WF/SY
Picture 1 2
Nominal distance 12 mm 17 mm
Operating sensor distance 0 … 9.72 mm 0 … 13.77 mm
Assembly built-in not built-in
Hysteresis 5 % 5 %
Repeatability < 0.01 mm < 0.01 mm
Standard target 36 x 36 mm 51 x 51 mm
Supply voltage 20 to 250 Vac (50 - 60 Hz) 20 to 250 Vac (50 - 60 Hz)
Maximum switching current 500 mA 500 mA
Consumption current < 10 mA < 10 mA
Transient Protection 1 kV / 10 ms / 10kW 1 kV / 10 ms / 10kW
Impulse Current 4 A 4 A
Residual voltage on load 3 mA 3 mA
Load minimum voltage 5 mA 5 mA
Sensor voltage drop £ 5 V £ 5 V
Maximum frequency 10 Hz 10 Hz
Signalling back led back led
Operating temperature - 25 ºC to + 70 ºC - 25 ºC to + 70 ºC
Protection rate IP 67 IP 67
Connection cable cable
Cable options PVC 6 m or polyurethane 2 m PVC 6 m or polyurethane 2 m
Casing nickelled brass nickelled brass
Cable Color
MR brown
AZ blue
VD / AM grounding
1-4.18
COMPLEMENTARY LINE
Output ConfigurationIEC 947-5-2 / IEC 1000-4-2.3.4.5
Mechanical
Inductive Proximity Sensors
M36
Alternating Current2 wires
WWAAMMRR((33))
AAZZ((44))
VVDD//AAMM((55))
2200 aa 225500VVccaa
NNAA
2
2
0
0
a
a
2
2
5
5
0
0
V
V
c
c
a
a
N
N
F
F
W
W
F
F
V
V
D
D
/
/
A
A
M
M
(
(
5
5
)
)
A
A
Z
Z
(
(
2
2
)
)
M
M
R
R
(
(
1
1
)
)
LEDLED
5050
SEXT. 42x5
SEXT. 42x5
M36x1,5
M36x1,5
Ø
Ø
3232
LEDLED
5050
SEXT. 42x5
SEXT. 42x5M
36x1,5
M36x1,5
1818
Page 19
NA PS12-36I-W3A/SY PS17-36I-W3A/SY PS12-36H-W4/S2X PS17-36H-W4/S2X
NF PS12-36I-W3F/SY PS17-36I-W3F/SY
Picture 1 2 3 4
Nominal distance 12 mm 17 mm 12 mm 17 mm
Operating sensor distance 0 … 9.72 mm 0 … 13.77 mm 0 … 9.72 mm 0 … 13.77 mm
Assembly built-in not built-in built-in not built-in
Hysteresis 5 % 5 % 5 % 5 %
Repeatability < 0.01 mm < 0.01 mm < 0.01 mm < 0.01 mm
Standard target 36 x 36 mm 51 x 51 mm 36 x 36 mm 51 x 51 mm
Supply voltage 20 to 250 Vac (50 - 60 Hz) 20 to 250 Vac (50 - 60 Hz) 90 to 250 Vac (50 - 60 Hz) 90 to 250 Vac (50 - 60 Hz)
Maximum switching current 500 mA 500 mA 500 mA 500 mA
Consumption current < 10 mA < 10 mA < 10 mA < 10 mA
Impulse Current 4 A 4 A 4 A 4 A
Transient Protection 1 kV / 10 ms / 10kW 1 kV / 10 ms / 10kW 1 kV / 10 ms / 10kW 1 kV / 10 ms / 10kW
Sensor voltage drop£ 1.5 V £ 1.5 V £ 1.5 V £ 1.5 V
Maximum frequency 10 Hz 10 Hz 10 Hz 10 Hz
Signalling back led back led back led back led
Operating temperature - 25 ºC to + 70 ºC - 25 ºC to + 70 ºC - 25 ºC to + 70 ºC - 25 ºC to + 70 ºC
Protection rate IP 67 IP 67 IP67 IP67
Connection cable 3 wires cable 3 wires cable 4 wires cable 4 wires
Tube length 50 mm 50 mm 79 mm 79 mm
Cable options PVC 6 m or polyurethane 2 m PVC 6 m or polyurethane 2 m PVC 6 m or polyurethane 2 m PVC 6 m or polyurethane 2 m
Casing nickelled brass nickelled brass nickelled brass nickelled brass
Cable Color
MR brown
AZ blue
PR black
BR white
VD / AM grounding
1-4.19
MechanicalDimensions
COMPLEMENTARY LINE
Output ConfigurationIEC 947-5-2 / IEC 1000-4-2.3.4.5
Inductive Proximity Sensors
M36
Alternating Current3 wires / 4 wires
PPRR((44))
BBRR((22))
AAZZ((33))
MMRR((11))
9900 aa 225500VVccaa
--
++WW44W
W
3
3
A
A
V
V
D
D
/
/
A
A
M
M
(
(
5
5
)
)
M
M
R
R
(
(
1
1
)
)
A
A
Z
Z
(
(
3
3
)
)
P
P
R
R
(
(
4
4
)
)
2
2
0
0
a
a
2
2
5
5
0
0
V
V
c
c
a
a
N
N
A
A
Ø
Ø
3232
LEDLED
5050
SEXT. 42x5
SEXT. 42x5M
36x1,5
M36x1,5
1818
LEDLED
5050
SEXT. 42x5
SEXT. 42x5
M36x1,5
M36x1,5
Page 20
NAMUR PS18-51G-N/SX PS25-51G-N/SX
( DIN - 19234 )
Picture 1 2
Nominal distance 18 mm 25 mm
Operating sensor distance 0 … 14.58 mm 0 … 20.25 mm
Assembly built-in not built-in
Hysteresis 5 % 5 %
Repeatability < 0.01 mm < 0.01 mm
Standard target 51 x 51 mm 75 x 75 mm
Supply voltage 7 to 12 Vdc 7 to 12 Vdc
Nominal voltage 8 Vdc ± 5 % 8 Vdc ± 5 %
Ripple 5 % 5 %
Voltage with the sensor activated £ 1 mA £ 1 mA
Voltage with the sensor disabled ³ 3 mA ³ 3 mA
Max. wiring resistance 100 W 100 W
Maximum frequency 100 Hz 100 Hz
Signalling without led without led
Operating temperature - 25 ºC to + 70 ºC - 25 ºC to + 70 ºC
Protection rate IP 67 IP 67
Connection cable cable
Tube length 87 mm 87 mm
Cable options PVC 6 m or polyurethane 2 m PVC 6 m or polyurethane 2 m
Casing nickelled brass nickelled brass
Cable Color
MR brown
AZ blue
1-4.20
COMPLEMENTARY LINE
Output ConfigurationIEC 947-5-2 / IEC 1000-4-2.3.4.5
Mechanical
Inductive Proximity Sensors
M51
Direct Current Namur
ØØ
M51x1,5
M51x1,5 SEXT. 6
4x7
SEXT. 64x7
1111
6565
8787
ØØ1313Ø
Ø
M51x1,5
M51x1,5
SEXT. 64x7
SEXT. 64x7
1111
6565
8787
ØØ1313
ØØ4848
2222
Page 21
NPN PS18-51G-A/SZ PS25-51G-A/SZ
PNP PS18-51G-A2/SZ PS25-51G-A2/SZ
Picture 1 2
Nominal distance 18 mm 25 mm
Operating sensor distance 0 … 14.58 mm 0 … 20.25 mm
Assembly built-in not built-in
Hysteresis 5 % 5 %
Repeatability < 0.01 mm < 0.01 mm
Standard target 51 x 51 mm 75 x 75 mm
Supply voltage 10 to 30 Vdc 10 to 30 Vdc
Ripple £ 10 % £ 10 %
Consumption current < 10 mA < 10 mA
Maximum switching current 200 mA ± 15 % 200 mA ±15 %
Output protection short-circuit and inversion short-circuit and inversion
Transient Protection 1 kV / 10 ms / 10kW 1 kV / 10 ms / 10kW
Sensor voltage drop< 2 V < 2 V
Maximum frequency 100 Hz 100 Hz
Signalling back led back led
Operating temperature - 25 ºC to + 70 ºC - 25 ºC to + 70 ºC
Protection rate IP 67 IP 67
Connection cable cable
Tube length 87 mm 87 mm
Cable options PVC 6 m or polyurethane 2 m PVC 6 m or polyurethane 2 m
Casing nickelled brass nickelled brass
Cable Color
MR brown
AZ blue
PR black
BR white
1-4.21
MechanicalDimensions
COMPLEMENTARY LINE
Output ConfigurationIEC 947-5-2 / IEC 1000-4-2.3.4.5
Inductive Proximity Sensors
M51
Direct Current4 wires
1100 aa 3300VVcccc
MMRR((11))NNPPNN
NA+NFNA+NF
-- AA
BBRR((22))
PPRR((44))
AAZZ((33)) --
++
Ø
Ø
M51x1,5
M51x1,5 SEXT. 6
4x7
SEXT. 64x7
1111
6565
8787
ØØ1313
LEDLED
Ø
Ø
M51x1,5
M51x1,5
SEXT. 64x7
SEXT. 64x7
1111
6565
8787
ØØ1313
LEDLED
ØØ4848
2222
Page 22
NA PS18-51G-WA/SY PS25-51G-WA/SY
NF PS18-51G-WF/SY PS25-51G-WF/SY
Picture 1 2
Nominal distance 18 mm 25 mm
Operating sensor distance 0 … 14.58 mm 0 … 20.25 mm
Assembly built-in not built-in
Hysteresis 5 % 5 %
Repeatability < 0.01 mm < 0.01 mm
Standard target 51 x 51 mm 75 x 75 mm
Supply voltage 20 to 250 Vac (50 - 60 Hz) 20 to 250 Vac (50 - 60 Hz)
Max. consumption current 500 mA 500 mA
Transient Protection 1 kV / 10 ms / 10kW 1 kV / 10 ms / 10kW
Impulse Current 4 A 4 A
Load residual voltage 3 mA 3 mA
Load minimum voltage 5 mA 5 mA
Sensor voltage drop£ 5 V £ 5 V
Maximum frequency 10 Hz 10 Hz
Signalling back led back led
Operating temperature - 25 ºC to + 70 ºC - 25 ºC to + 70 ºC
Protection rate IP 67 IP 67
Connection cable cable
Tube length 87 mm 87 mm
Cable options PVC 6 m or polyurethane 2 m PVC 6 m or polyurethane 2 m
Casing nickelled brass nickelled brass
Cable Color
MR brown
AZ blue
VD / AM grounding
1-4.22
COMPLEMENTARY LINE
Output ConfigurationIEC 947-5-2 / IEC 1000-4-2.3.4.5
Mechanical
Inductive Proximity Sensors
M51
2200 aa 225500VVccaa
NNFF
WWFF
VVDD//AAMM((55))
AAZZ((22))
MMRR((11))
Ø
Ø
M51x1,5
M51x1,5 SEXT. 6
4x7
SEXT. 64x7
1111
6565
8787
ØØ1313
LEDLED
Ø
Ø
M51x1,5
M51x1,5
SEXT. 64x7
SEXT. 64x7
1111
6565
8787
ØØ1313
LEDLED
ØØ4848
2222
W
W
A
A
M
M
R
R
(
(
3
3
)
)
A
A
Z
Z
(
(
4
4
)
)
V
V
D
D
/
/
A
A
M
M
(
(
5
5
)
)
2
2
0
0
a
a
2
2
5
5
0
0
V
V
c
c
a
a
N
N
A
A
Alternating Current2 wires
Page 23
NA PS18-51G-W3A/SY PS25-51G-W3A/SY PS18-51G-W4/S2X PS25-51G-W4/S2X
NF PS18-51G-W3F/SY PS25-51G-W3F/SY
Picture 1 2 3 4
Nominal distance 18 mm 25 mm 18 mm 25 mm
Operating sensor distance 0 … 14.58 mm 0 … 20.25 mm 0 … 14.58 mm 0 … 20.25mm
Assembly built-in not built-in built-in not built-in
Hysteresis 5 % 5 % 5% 5%
Repeatability < 0.01 mm < 0.01 mm < 0.01 mm < 0.01 mm
Standard target 51 x 51mm 75 x 75 mm 51 x 51 mm 75 x 75 mm
Supply voltage 20 to 250 Vac (50 - 60 Hz) 20 to 250 Vac (50 - 60 Hz) 90 to 250 Vac (50 - 60 Hz) 90 to 250 Vac (50 - 60 Hz)
Maximum switching current 500 mA 500 mA 500 mA 500 mA
Consumption current < 10 mA < 10 mA < 10 mA < 10 mA
Impulse Current 4 A 4 A 4 A 4 A
Transient Protection 1 kV / 10 ms / 10kW 1 kV / 10 ms / 10kW 1 kV / 10 ms / 10kW 1 kV / 10 ms / 10kW
Sensor voltage drop £ 1.5 V £ 1.5 V £ 1.5 V £ 1.5 V
Maximum frequency 10 Hz 10 Hz 10 Hz 10 Hz
Signalling back led back led back led back led
Operating temperature - 25 oC to + 70 oC - 25 oC to + 70 oC - 25 oC to + 70 oC - 25 oC to + 70 oC
Protection rate IP 67 IP 67 IP 67 IP 67
Connection cable 3 wires cable 3 wires cable 4 wires cable 4 wires
Tube length 87 mm 87 mm 87 mm 87 mm
Cable options PVC 6 m or polyurethane 2 m PVC 6 m or polyurethane 2 m PVC 6 m or polyurethane 2 m PVC 6 m or polyurethane 2 m
Casing nickelled brass nickelled brass nickelled brass nickelled brass
Cable Color
MR brown
AZ blue
PR black
BR white
VD / AM grounding
1-4.23Rev.A - 11/2013
MechanicalDimensions
COMPLEMENTARY LINE
Output ConfigurationIEC 947-5-2 / IEC 1000-4-2.3.4.5
Inductive Proximity Sensors
M51
Alternating Current 3 wires / 4 wires
WW33AA
VVDD//AAMM((55))
MMRR((11))
AAZZ((33))
PPRR((44))2200 aa 225500VVccaa
NNAA
P
P
R
R
(
(
4
4
)
)
B
B
R
R
(
(
2
2
)
)
A
A
Z
Z
(
(
3
3
)
)
M
M
R
R
(
(
1
1
)
)
9
9
0
0
a
a
2
2
5
5
0
0
V
V
c
c
a
a
-
-
+
+
W
W
4
4
Ø
Ø
M51x1,5
M51x1,5 SEXT. 6
4x7
SEXT. 64x7
1111
6565
8787
ØØ1313
LEDLED
Ø
Ø
M51x1,5
M51x1,5
SEXT. 64x7
SEXT. 64x7
1111
6565
8787
ØØ1313
LEDLED
ØØ4848
2222