Test Report. No. SHAEC2022262023 A01 Date: 04 Dec 2020 . Page 1 of 17 . JIANGSU CHANGJING ELECTRONICS TECHNOLOGY CO.,LTD . 13 TH FLOOR,C BLOCK,TENGFEI BUILDING,NO.88 . THIS REPORT IS TO SUPERSEDE TEST REPORT NO.SHAEC2022262003.. The following sample(s) was/were submitted and identified on behalf of the clients as : DIODE . SGS Job No. : SP20-034533 - SUZ . Model No. : . SMAF. Client Ref. Information : . R-1、R-6、A-405、6GBJ、ABS、DB、DBS、DO-15、DO-27、DO-35、DO-41 、GBJ、GBL、GBP、GBU、JBF、JBSL、KBL、KBP、KBU、MBF、MBS、S MA、SMAF、SMAG、SMAJ、SMB、SMBF、SMBG、. SMBJ、SMCG、SMD、SOD-123FL 、SOT-223 、SOT-23 、SOT-89 、TO-126 、 TO-220 、TO-220F 、TO-247 、TO-251 、TO-251S 、TO-252 、TO-263 、TO-3P. Date of Sample Received : . 06 Nov 2020 . Testing Period : . 06 Nov 2020 - 12 Nov 2020 . Test Requested : . Selected test(s) as requested by client. . Please refer to next page(s). . Please refer to next page(s). . Test Method : . Test Results : . Conclusion : . Based on the performed tests on submitted sample(s), the results of Cadmium, Lead, Mercury, Hexavalent chromium, Polybrominated biphenyls (PBBs), Polybrominated diphenyl ethers (PBDEs) and Phthalates such as Bis(2-ethylhexyl) phthalate (DEHP), Butyl benzyl phthalate (BBP), Dibutyl phthalate (DBP) and Diisobutyl phthalate (DIBP) comply with the limits as set by RoHS Directive (EU) 2015/863 amending Annex II to Directive 2011/65/EU. . Tom Ni . Approved Signatory . Signed for and on behalf of SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd..
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Test Report. No. SHAEC2022262023 A01 Date: 04 Dec 2020 . Page 1 of 17.
(2)▼ = a. The sample is positive for CrVI if the CrVI concentration is greater than 0.13 μg/cm².
The sample coating is considered to contain CrVI
b. The sample is negative for CrVI if CrVI is ND (concentration less than 0.10 μg/cm²). The
coating is considered a non-CrVI based coating
c. The result between 0.10 μg/cm² and 0.13 μg/cm² is considered to be inconclusive -
unavoidable coating variations may influence the determination
Information on storage conditions and production date of the tested sample is unavailable
Test Report. No. SHAEC2022262023 A01 Date: 04 Dec 2020 . Page 5 of 17.
and thus Cr(VI) results represent status of the sample at the time of testing. .
This report updates Client Ref. Information. .
Test Report. No. SHAEC2022262023 A01 Date: 04 Dec 2020 . Page 6 of 17.
ATTACHMENTS
Elements (IEC62321) Testing Flow Chart
1) Name of the person who made testing: Meria Jin/Sielina Song 2) Name of the person in charge of testing: Luna Xu/Bob Zhang 3) These samples were dissolved totally by pre-conditioning method according to below flow chart.
Sample Preparation
Sample Measurement
ICP-OES/AAS
Solution
Filtration
Residue
1) Alkali Fusion / Dry Ashing
2) Acid to dissolve
Acid digestion with microwave/ hotplate
DATA
Test Report. No. SHAEC2022262023 A01 Date: 04 Dec 2020 . Page 7 of 17.