FOR INDUSTRIES, BUILDINGS AND PROCESS APpLICATIONS FOR INDUSTRIES, BUILDINGS AND PROCESS ApPLICATIONS Product F e atures Energy Saver Low Noise Level Low Drift Loss Quake proof Design Guaranteed Thermal Performance Product Features Energy Saver Low Noise Level Low Drift Loss Quake proof Design Guaranteed Thermal Performance APC SERIES COUNTER FLOW ROUND TYPE ALPHA VINA COOLING TOWER INDUSTRY ALPHA VINA COOLING TOWER INDUSTRY
8
Embed
CTL Alpha cooling · FOR INDUSTRIES, BUILDINGS AND PROCESS APpLICATIONSPROCESS ApPLICATIONS Product Features Energy Saver Low Noise Level Low Drift Loss Quake proof Design Guaranteed
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
FOR INDUSTRIES,
BUILDINGS AND
PROCESS APpLICATIONS
FOR INDUSTRIES,
BUILDINGS AND
PROCESS ApPLICATIONS
Product Features Energy Saver Low Noise Level Low Drift Loss Quake proof Design Guaranteed Thermal Performance
Product Features Energy Saver Low Noise Level Low Drift Loss Quake proof Design Guaranteed Thermal Performance
APC SERIESCOUNTER FLOWROUND TYPE
ALPHA VINA COOLING TOWER INDUSTRYALPHA VINA COOLING TOWER INDUSTRY
Induced Draft Counter FlowCooling Tower
(Bottle Type)
MATERIAL SPECIFICATION
2
STRUCTURE INDUCED DRAFT COUNTER FLOW
Cooling Water Flow
Air Flow
121
4
5
6
7
9
14
13
10
11
3
2
8
STRUCTURE1. MOTOR & FAN DRIVE2. AIR INLET MESH3. TOWER CASE4. FAN BLADE & HUB5. SPRINKLER HEAD6. DRIFT ELIMINATOR7. FILLER8. WATER BASIN9. FILLER SUPPORT10. FAN GUARD11. MOTOR SUPPORT12. LADDER13. AUX. SUCTION TANK14. BASIN SUPPORT
1. MOTOR & FAN DRIVE2. AIR INLET MESH3. TOWER CASE4. FAN BLADE & HUB5. SPRINKLER HEAD6. DRIFT ELIMINATOR7. FILLER8. WATER BASIN9. FILLER SUPPORT10. FAN GUARD11. MOTOR SUPPORT12. LADDER13. AUX. SUCTION TANK14. BASIN SUPPORT
Technical information for requirements.1. Circulating water volume (LPM or M3/Hr)2. Tower inlet water temperature (oC)3. Tower outlet water temperature (oC)4. Wet Bulb temperature or Dry Bulb temperature (oC) and relative humidity (%)5. Area size and site condition6. Water quality7. Power Supply: voltage and frequency8. Purpose of tower usage9. Any other items of preference
4 50
P
W
S>1/3 D
D
INSTALLATION INSTRUCTION1.Location selectiona. Either indoor or outdoor place is appropriate for a cooling tower installationb. In case of 2 cooling towers are installed, there should be appropriate spaces between the first cooling tower and the second one.
c. Keep proper distance between a cooling tower and the enclosures
d. In case of multi cells installed in Iine, should be concerned about the air flow directions.
e. Avoid any places where corrosive gases exist includ-ing chimneys and host springf.Keep cooling tower away from hot temperature place.g. Keep cooling tower away from the smoke and dusty area.h. Keep cooling tower away from high voltage line or a transformer.
2. Positiona. Make sure that the tower is placed vertically because inconsistent sprinkle will lower the cooling tower efficiency. See pictures below.b. Tighten the anchor bolts.
3. Pipinga. The inlet and outlet pipes must be installed lower than the pipe connections of the water sumps. See pictures below.
b. The size of pipe should be as same as the pipe connections of the water sumps. A smaller size one will drop the cooling tower efficiency and the larger size pipe will waste the material.c. The circulating pump must be located below the water sump under normal operation. See pictures below.
d. 2 cooling towers which operate by a pump need to be place equally in order to balance the water level in both cooling towers.
e. High pressure flexible tubes must be used at the joists of circulating inlets and outlets with sizes over 4 inches (100mm) to avoid some vibration from the piping and prevent the water basin breaks which may cause by improper piping installation.
4. Other:a. After the installation is complete, check that there are no tools or any other objects left in the towerb. Make sure that both piping and water basin are not leaking.c. When the pressure of make up water is low, install either a water tank highter than the water level or install a water make up pump somewhere in the piping system to obtain more water pressure.
Correct Incorrect
IncorrectCorrect
Correct
Correct
Incorrect
PP
S S S > 1 / 2 D
S
1
2 3
50 Hz
14 m
1.5m
2 m
SOUND LEVEL