CTA UCM-ELECTRONICS. Members and EPOs with active participation UCM-ELECTRONICS. Members and EPOs with active participation Dr. J.J. Jimenez, “Profesor Titular de Universidad”. Headmaster of the Electronics department. Full time Dr. M.C. Perez. “Profesor Titular de Universidad”. Full time dedication to the project. Dr. J.C. Jimenez, “Profesor Titular de Universidad”. Full time dedication to the project. Expertise in Solid state devices Microelectronics Monte Carlo simulation of different technologies involved in solid state Mr. Teodoro Bernardino Santos. Manager of different projects related to satellite based timing and european navegation systems. Pursuing the PhD degree. Expertise in high frequency electronics. Deep knowledge on state of the art hardware for synchronization and timing. Mr. Lamberto Fresnillo. Manager of Fidias. Pursuing the PhD degree. European auditor in quality control (EOQ). Expertise in quality control and reliability analysis. Close contact with industries involved in key technologies for CTA. Dr. J.M. Miranda. “Profesor Titular de Universidad”. Full time dedication to the project. P. Antoranz, “Ayudante de Universidad”. Physicist and Electronic Engineer. Full time dedication to the project. Long standing experience working in hardware for Cherenkov telescopes. MAGIC members since 2005 Expertise in high frequency electronics and electromagnetic compatibility. Joining efforts
10
Embed
CTA UCM-ELECTRONICS. Members and EPOs with active participation Dr. J.J. Jimenez, “Profesor Titular de Universidad”. Headmaster of the Electronics department.
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
CTAUCM-ELECTRONICS. Members and EPOs with active participationUCM-ELECTRONICS. Members and EPOs with active participation
Dr. J.J. Jimenez, “Profesor Titular de Universidad”.Headmaster of the Electronics department.Full time dedication to the project.
Dr. M.C. Perez. “Profesor Titular de Universidad”.Full time dedication to the project.
Dr. J.C. Jimenez, “Profesor Titular de Universidad”.Full time dedication to the project. Expertise in
Solid state devices Microelectronics Monte Carlo simulation
of different technologies involved in solid state photodetectors.
Mr. Teodoro Bernardino Santos. Manager of different projects related to satellite based timing and european navegation systems. Pursuing the PhD degree.Expertise in high frequency
electronics. Deep knowledge on state of the art hardware for
synchronization and timing.
Mr. Lamberto Fresnillo. Manager of Fidias. Pursuing the PhD degree. European auditor in quality control (EOQ).
Expertise in quality control and reliability analysis. Close contact with industries involved in key technologies
for CTA.
Dr. J.M. Miranda. “Profesor Titular de Universidad”.Full time dedication to the project.
P. Antoranz, “Ayudante de Universidad”. Physicist and Electronic Engineer. Full time dedication to the project.
Long standing experience working in hardware for Cherenkov telescopes.
MAGIC members since 2005
Expertise in high frequency electronics and electromagnetic compatibility.
Joining efforts
CTA
ELECTRONICSELECTRONICSGROUP at UCMGROUP at UCM
Mr. Ricardo Padrino will become Electronic Engineer soon. Presently preparing his degree project on signal conditioning and test of GAPD clusters.
Mr. Ignacio Vegas is Electronic Engineer. He is presently pursuing the PhD degree and about to defend his master thesis. He has worked in evaluation boards for MAGIC II telescope hardware testing. First author of a technical application note for the MAGIC collaboration.
The youngest collaborators.
Four of us are teachers in Electronic Engineering and Physics. We are in an excellent situation to
find and recruit young and highly motivated people with important skills for CTA.
CTAUCM-ELEC GROUP have well equipped laboratories UCM-ELEC GROUP have well equipped laboratories
FACILITIESFACILITIES 80 m2 clean room class 100,000 for high reliability litography and
prototype fabrication. GTEM cell for Electromagnetic Compatibility (EMC) Compliance tests. Standard and advanced facilities for SMD board prototyping. High precision soldering and rework stations.
INSTRUMENTATIONINSTRUMENTATION Vector Network Analyzer (VNA) with high precision calibration kit. Spectrum Analyzer for noise and nonlinear analysis. Dynamic Signal Analyzer Agilent 35670A for reliability tests. Specific instrumentation for phase noise and jitter measurements. Portable Electromagnetic field meters EMC test facilities for radiated and conducted interference monitoring. Commercial ns-range pulse generators for testing. Laser and pulsed LED sources for photodetector testings.
3/10
CTA
0 10 20102
103
104 2-DEG (GaAs/AlGaAs)
As4
TN(K
)
As2
I(mA)
Transistors for pulse
amplifiers (1997-2002)
Activities: Noise metrology for reliability and failure predictionActivities: Noise metrology for reliability and failure prediction
Failure diagnostics of solid statedevices based on noise measurements.
28 min
TN(K)
23 min
C series
X series
13 min 18 min8 min
10-7
10-5
10-3
100
200
300
400
500
I(A)
Noise of solid state photodetectors (1995-1999)
CTAActivities: Fabrication and test of high frequency low noise amplifiersActivities: Fabrication and test of high frequency low noise amplifiers
Quantum noise limit
2000-2004.Low noise measurements and design of criogenically cooled amplifier for the Square Kilometer Array (SKA) facility. Measured and modeled noise vs frequency at temperatures of 300 K, 77 K, and 4.2 K.
To Port 2
To Port 1
2
3 4
5
6
Ultra low noise Monolithic Microwave Integrated Circuit (MMIC) amplifier. Noise figure of 3 dB and G=20 dB
1.2 mm
Grounded-gate low power consumption amplifier (60 mW)
CTAUCM-ELEC. Previous fund and corresponding resultsUCM-ELEC. Previous fund and corresponding results
1 peer reviewed paper (high frequency modelling of LEDs)
2 MAGIC internal notes
2 peer reviewed papers (testbenches and central pixel)
6 peer reviewed conference presentations.
4 Electronic engineering projects
2 Msc thesis
1 PhD thesis (to be read in September)
See presentation of MV Fonseca for further details:FPA2009-08938 ASTROFISICA DE ALTAS ENERGIAS CON MAGIC
Astrofísica de altas energías con MAGIC FPA2006-12383-C02-01 (2006-2009) EDP of 8 (1.5 from UCM-ELEC)MV Fonseca608 k€
Pulse amplifiers for MAGIC II camera and receiver boards.
Software tools.
Multichannel eval boards with ns pulse generators.
MAGIC shifts according to the MAGIC CB policies.
MAGIC I central pixel design and test (in collaboration with UCM-GAE, IFAE and other
researchers).
Test benches for single photoelectron counting, noise and pulse distortion measurements of
PMT, HPD and GAPD-based pixels (in collaboration with UCM-GAE, IFAE and other researchers).
CTAUCM-ELEC. Previous fund and corresponding results (only 2 EDP)UCM-ELEC. Previous fund and corresponding results (only 2 EDP)
Development of test bench for GAPD based on new pulsed LED head.
Barcelona, March 2009. Presentation of the amplifiers designed by UCM-ELEC in a
meeting with HESS researchers, including the main responsible of the WP ELEC
(Pascal Vincent)
May 2009, Cracow. Attendance to the CTA meeting, with two important decisions:
Manel Martinez and Werner Hofmann elected as spoke-persons.
CB board and CTA groups configured by consensus. All the PIs of the subprojects
presented in this application are members of it.
“Participación Española en la puesta en marcha del Estudio de Diseño del Cherenkov Telescope Array (CTA)”
Manel Martínez – IFAE
FPA2007-30012-E 10 k€FPA2007-31120-E 74 K€
CTATask Descripcion Year UCM-GAE UCM-ELEC CIEMAT UAB IFAE UB ICE-CSIC IAC1 Camera prototyping for large telescope
1a Photosensor testing and characterization 1 X X X1b Structure, mechanics and cooling 2.3 X1c Front-end 1.2.3 X X1d Readout and trigger 1.2.3 X X X X1e Slow control 2.3 X X1f Readout software 2.3 X
1g Power supplies, calibration and monitoring 1.2.3 X X2 R&D new photosensors
2a Solid state technologies 1.2.3 X X2b Integration 1.2 X X2c Cluster prototype 2.3 X X2d Modelling 1.2 X
3 GRID 1.2.3 X4 ATAC
4a Raman LIDAR 1.2 X X X4b CLF 1.2.3 X X4c Integration 2.3 X X X4d Telescope calibration 1.2 X X4e Modelling 1,2,3 X X X
5 Physics 1.2.3 X X X X X X X6 Monte Carlo 1.2.3 X X7 SITE 1.2.3 X X X X8 GPS and RF
8a GPS synchronization 1.2.3 X8b RF link 1.2.3 X
Objectives and requested Objectives and requested budgetbudget
Our objectives were chosen considering:
Needs of CTA collaboration CTA schedule Our previous work Our expertise Our links with industry