Top Banner
CS-100 CS-100 CS Marketing Group, LLC CS Marketing Group, LLC
19
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: CS-100 CS Marketing Group, LLC CS Marketing Group, LLC.

CS-100CS-100

CS Marketing Group, LLCCS Marketing Group, LLC

Page 2: CS-100 CS Marketing Group, LLC CS Marketing Group, LLC.

CS-100 (Cardio Scan 100)

An Acquisition and FCG (Frequency Cardiograph) Spectrum Diagnostic System

A Preliminary Screening Tool

To Detect Coronary Artery Diseases (CAD)

Early Ischemia to Myocardial Infarction

presentation

Copyright, Trigon Medical Devices Inc. 2011 204/11/23

Page 3: CS-100 CS Marketing Group, LLC CS Marketing Group, LLC.

Copyright, Trigon Medical Devices Inc. 2011 3

Cardiovascular Disease

The #1 killer and cause of disability in the world

- 1 million deaths in the U.S. and 17 million worldwide every year. - Debilitates more than 5 million every year.

Approximately 23% of myocardial infarctions go undetected. - #1 cause of sudden death - Irreversible debilitating condition

Over $30 billion in payments were made to Medicare beneficiaries for hospital expenses.

CS-100 meets the need for a risk free and cost effective screening tool to detect ischemic heart diseases in its early stage. - Preventive screening tool for primary care physicians - Detect ischemic condition that is reversible by exercise and dietary change

04/11/23

Page 4: CS-100 CS Marketing Group, LLC CS Marketing Group, LLC.

Copyright, Trigon Medical Devices Inc. 2011 4

CS-100 RESEARCH AND DEVELOPMENT A Different Approach

- More than 30 years research and development.

- Heart is a dual functioning machine – electric generator and pump.

- Change in heart’s physiology will cause change in EKG waveform.

- Apply Digital Signal Processing Principles in digitizing and transforming 12 lead ECG into frequency components of energy value (uV) at frequency (Hz).

- Use differential diagnosis to identify and select diagnostic indexes. - Statistically compare the value of each index against the value from the data base to determine abnormal (+) or normal (-) for each diagnostic index.

- From (+) indexes to detect ischemic condition from early ischemia to myocardial infarction.

04/11/23

Page 5: CS-100 CS Marketing Group, LLC CS Marketing Group, LLC.

Electrodes Electrodes

Time Domain CardiacElectrical CurrentsTime Domain CardiacElectrical Currents

Complied andRecordedComplied andRecorded

ECGElectrocardiogram ECGElectrocardiogram

FFT (Fast FourierTransformation) Into Frequency Components

FFT (Fast FourierTransformation) Into Frequency Components

Digital Signal Analysis(1) Power Spectrum(2) Phase Shift(3) Impulse Response

Digital Signal Analysis(1) Power Spectrum(2) Phase Shift(3) Impulse Response

FCGFrequency Cardiograph and Diagnostic Indexes

FCGFrequency Cardiograph and Diagnostic Indexes

Index Value - Data Base(30,000 tests)

Index Value - Data Base(30,000 tests)

Schematic Flow Chart of CS-100

Copyright, Trigon Medical Devices Inc. 2011 504/11/23

Page 6: CS-100 CS Marketing Group, LLC CS Marketing Group, LLC.

COMPARISON OF TESTS TO DIAGNOSE HEART DISEASES

Test Average Test Risk Time Cost/Test Accuracy Limitation

Stress Test Moderate 20 min. $300 50-70% High false reading for abnormal ECG

Chemical Moderate 4 hours. $3,800 80-90% Higher false positive ifStress Test hypertensive

Angiogram High 8 hours. $10,000 95-98% Highly invasive, expensive

CS-100 None 12 min. $2,000 94-97% Accuracy is similar to heart catheterization, non-

invasive.

* The expensive and non-routinely used Ultra-Fast CT Scan & PET technology are not included for comparison.

Copyright, Trigon Medical Devices Inc. 2011 604/11/23

Page 7: CS-100 CS Marketing Group, LLC CS Marketing Group, LLC.

CS - 100

ADVANTAGES & BENEFITS- Non-Invasive (No Injection or catheters required)

- No Strenuous Exercise Required (Patient is at rest)

- Safe and Easy to Operate

- On-site Diagnosis for CAD in 12 minutes

- High Sensitivity

- High Specificity

- Limited Training Required

- Cost Efficient

Copyright, Trigon Medical Devices Inc. 2011 704/11/23

Page 8: CS-100 CS Marketing Group, LLC CS Marketing Group, LLC.

What the Experts Say:

“This technology (cardio spectrum diagnostic system) is a signature new method of early Screening for heart diseases. It is --- a very simple, fast, and non-invasive method ----- and should be used in clinics where cardiac screening is performed, as well as by primary care physicians.” William J. Tenet, M.D., New York Hospital – Medical Center of Queens

“This technology (cardio spectrum diagnostic system) will provide a significant new method of early diagnosis of heart diseases.” Marne Def. Gomes, M.D., Dean of Institute of Cardiology, Foundation University of Cardiology – Brazil

“Frequency Domain FCG may index LVH with a high accuracy and the prediction of MID is largely superior (based on F statistics) to standard time-domain ECG parameters, either taking voltage alone or time-voltage integral into consideration. It may thus be a new tool to help indexing the probabilistic presentation of LVH.” Paolo Emilio Puddu, Institute of Heart and Great Vessels, Ls Sapienza University, Rome, Italy

Copyright, Trigon Medical Devices Inc. 2011 804/11/23

Page 9: CS-100 CS Marketing Group, LLC CS Marketing Group, LLC.

Copyright, Trigon Medical Devices Inc. 2011 9

CS – 100 Opening Page

FCG Spectrum Analysis

04/11/23

Page 10: CS-100 CS Marketing Group, LLC CS Marketing Group, LLC.

CS-100 Important Features

- This device complies with the accepted specifications to provide the maximum safety to patients and operators.

- A Window based touch screen diagnostic system with an easy to operate menu.

- Acquire 10 leads ECG signal simultaneously and continuously for up to one hundred and ten seconds.

- Two ECG time-domain waveform display (6x2 and 12x1).

- Frequency Analysis with CS-100 spectrum displays.

- Five power spectrum diagnostic indexes for each of the 12 leads.

-- Five special diagnostic indexes for Lead II and V5.

Copyright, Trigon Medical Devices Inc. 2011 1004/11/23

Page 11: CS-100 CS Marketing Group, LLC CS Marketing Group, LLC.

12x1 ECG Wave Display

ECG (Electrocardiograph)

- CS-100 has the ECG data acquisition capability to acquire and record a conventional 12 lead ECG simultaneously; and

- to display and print out the ECG graph in two different formats: 12x1 and 6x2

Copyright, Trigon Medical Devices Inc. 2011 1104/11/23

Page 12: CS-100 CS Marketing Group, LLC CS Marketing Group, LLC.

6 x 2 ECG Wave Display

Copyright, Trigon Medical Devices Inc. 2011 12

- Also can display and print out a 6 x 2 ECG

04/11/23

Page 13: CS-100 CS Marketing Group, LLC CS Marketing Group, LLC.

FCG (Frequency Cardiogram)

Unique and Valuable System

- An Innovative and scientifically proven system.

- High degree of sensitivity and accuracy.

- Cardiac screening for early diagnosis of heart disease.

- Preventive warning for reversible ischemia.

- Detection of ischemic myocardium injuries which may eventually lead to more serious heart problems.

Copyright, Trigon Medical Devices Inc. 2011 1304/11/23

Page 14: CS-100 CS Marketing Group, LLC CS Marketing Group, LLC.

04/11/23 Copyright, Trigon Medical Devices Inc. 2011 14

FCG (Frequency Cardiogram)

Advanced Technology

- Automatically amplify, filter and digitize the 12 lead cardio-electrical signals;- Transform those digitized signals into 12 individual frequency domain spectra; - Calculate and Determine (+) or (-) for each diagnostic index; - Frequency range from 0 Hz to 25.6 Hz with much refine 0.2 Hz resolution

Display and Print-out

- one page of power spectra with 60 diagnostic indexes (one power spectrum with 5 indexes for each of the 12 lead); - a multi-color CAD location picture, and - frequency graph for power spectrum, phase angle shift and impulse response and their respective diagnostic indexes for lead II and V.

Page 15: CS-100 CS Marketing Group, LLC CS Marketing Group, LLC.

12-Lead FCG Power Spectra with Ischemic Diagnostic Indexes

C. FCG Power Spectrum

- CS-100 displays and prints out a power spectrum with all 12 leads on one page;- Each power spectrum lists five (5) ischemic diagnostic indexes

Copyright, Trigon Medical Devices Inc. 2011 1504/11/23

Page 16: CS-100 CS Marketing Group, LLC CS Marketing Group, LLC.

04/11/23 Copyright, Trigon Medical Devices Inc. 2011 16

12 LEAD POWER SPECTRUM can detect - Insufficient myocardial energy caused by lack of blood supply (Early Ischemia)

- Myocardium injuries

- Ventricular hypertrophy or Ischemic Cardiomyopathy

- Myocardial Ischemia

- Myocardial compensation has set in for one or more years

- CAD and its location

Page 17: CS-100 CS Marketing Group, LLC CS Marketing Group, LLC.

04/11/23 Copyright, Trigon Medical Devices Inc. 2011 17

E. Two Lead Analysis:

- analyze the digitized data from the two leads (V5 and II) to determine the (+) or (-) for one diagnostic index designated for phase shift and five (5) indexes for impulse response; and- Display and print out a two-lead frequency graph showing two power spectra (one for lead II and one for lead V5, one phase shift and one impulse response.

FCG Power Spectra for Lead II and Lead V5, and Their Phase Shift and Impulse Response

Page 18: CS-100 CS Marketing Group, LLC CS Marketing Group, LLC.

04/11/23 Copyright, Trigon Medical Devices Inc. 2011 18

- Poor blood flow to the heart, poor blood circulation and change of blood dynamics.

- Poor or defective conduction function, unstable cardiac electricity.

- Left bundle branch conduction block.

- CAD , coronary artery blockage, or myocardial infarction (MI).

- Unstable latent cardiac electrical activities at the beginning of contraction.

Two Lead Analysis can detect:

Page 19: CS-100 CS Marketing Group, LLC CS Marketing Group, LLC.

04/11/23 Copyright, Trigon Medical Devices Inc. 2011 19

For More Information Contact:

CS Marketing Group, LLC

Email: [email protected]