Crossover Matrix EJA-A Series to EJA-E Series PCO-501 Original Issue April 2013 1st Edition April 2013 Yokogawa Corporation of America 2 Dart Road; Newnan, Georgia U.S.A. 30265 Tel: 1-800-888-6400 鞨 Introduction This Crossover Matrix is designed to quickly and accurately convert an EJA-A series transmitter to the new EJA-E series transmitter. 鞨 Applicable Models EJA110A, EJA120A, EJA130A, EJA210A, EJA220A, EJA310A, EJA430A, EJA440A, EJA510A, and EJA530A 鞨 Instructions This Matrix is a simple cross match system. Corresponding EJA-E code and position EJA-A Series code EJA-A Series Code Description EJA-E Series Code Description Availability of EJA-A Series Option in EJA-E Series 鞨 Symbol Key
18
Embed
Crossover Matrix EJA-A Series to EJA-E Seriesweb-material3.yokogawa.com/Crossover Matrix EJA-A to EJA-E.pdf · Crossover Matrix EJA-A Series to EJA-E Series PCO-501 ... /E1 Stainless
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
EJA430A to EJA430A Page 12 EJA440A to EJA440E Page 12
>In-Line Transmitter
EJA510A to EJA510E Page 15 EJA530A to EJA530E Page 15
3
EJA110A, EJA120A, and EJA130AStartHere
Transmitter Type (Pressure Type) - X X X X X - X X X X X / ….EJA110A Differential Pressure EJA110E - - / Differential PressureEJA120A Differential Pressure EJA120E - - / Differential PressureEJA130A Differential Pressure EJA130E - - / Differential Pressure
Output Signal-D 4 to 20 mA with BRAIN - D - / 4 to 20 mA with BRAIN-E 4 to 20 mA with HART 5 - J - / 4 to 20 mA with HART 5/7-F FOUNDATION Fieldbus - F - / FOUNDATION Fieldbus-G PROFIBUS PA X X X - - / Future Option
Measurement Span (Capsule)E 0.4 to 4 inH X X - E - / 0.4 to 4 inHL 2 to 40 inH - F - / 2 to 20 inH Wetted Part Material code S)
- L - /M 4 to 400 inH X - M - / 4 to 400 inHH 20 to 2000 inH X - H - / 20 to 2000 inHV 20 to 2000 psi X X - V - / 20 to 2000 psi
Wetted Parts MaterialS Hastelloy / 316 SST / 316 SST - S - / Hastelloy / 316 SST / 316 SSTH Hastelloy / Hastelloy / 316 SST X X - H - / Hastelloy / Hastelloy / 316 SSTM Monel / Monel / 316 SST X X - M - / Monel / Monel / 316 SSTT Tantalum / Tantalum / 316 SST X X - T - / Tantalum / Tantalum / 316 SSTA Hastelloy / Hastelloy / Hastelloy X X - A - / Hastelloy / Hastelloy / HastelloyD Tantalum / Hastelloy / Hastelloy X X - D - / Tantalum / Hastelloy / HastelloyB Monel / Monel /Monel X X - B - / Monel / Monel /Monel
Electrical Connection0 G 1/2 - - 0 / G 1/22 1/2 NPT - - 2 / 1/2 NPT 3 Pg 13.5 X X X - - / Not Avialable4 M20 - - 4 / M205 G 1/2 with Plug - - 5 / G 1/2 with Plug7 1/2 NPT with Plug - - 7 / 1/2 NPT with Plug8 Pg 13.5 with Plug X X X - - / Not Avialable9 M20 with Plug - - 9 / M20 with PlugA G 1/2 with 316 SST Plug - - A / G 1/2 with 316 SST PlugC 1/2 NPT with 316 SST Plug - - C / 1/2 NPT with 316 SST PlugD M20 with 316 SST Plug - - D / M20 with 316 SST Plug
DisplayD Display - - D / DisplayE Display with switch - - E / Display with switchN No Display - - N / No Display
BracketA - - B /B - - B /J - - J /C - - D /D - - D /K - - K /N None - - N / None
EXAMPLE: EJA110E - J M S 5 G - 9 2 E N /
Continued on next page Determine Amplifier Housing Material code per EJA-E GS to complete model code.
PCO-501Original Issue April 20131st Edition April 2013
EJA1
30E
X X
EJA1
10E
EJA1
20E
4
EJA110A, EJA120A, and EJA130AContinueHere
Agency Approvals (Optional) EJAxxxE - X X X X X - X X X X X / …./FF1 FM Explosionproof - -
/FF15 FM Explosionproof (Fieldbus) - -/FS1 FM Intrinsically Safe - - / FS1 FM Intrinsically Safe
/FS15 FM Intrinsically Safe (Fieldbus) - - / FS15 FM Intrinsically Safe (Fieldbus)/FU1 FM Combo - - / FU1 FM Combo /KF21 ATEX Flameproof - - / KF22 ATEX Flameproof/KS2 ATEX Intrinsically Safe - - / KS21 ATEX Intrinsically Safe
Custom Software (Option)/R1 Custom Software X X X - - / Not available
Body Options (Option)/N1 No drain or vent plugs - - / N1 No drain or vent plugs/N2 N1 with kidney flange - - / N2 N1 with kidney flange/N3 N2 with material certs - - / N3 N2 with material certs
Wired on Tag (Option)/N4 Wired on Tag - - / N4 Wired on Tag
Low volume cover flange (Option)/N5 For remote seal attachment X X - W - / For remote seal attachment
Fieldbus Options (Option)/LC1 PID Control - - / Standard - no option code required/EE Software Download - - / EE Software Download
Data Configuration (Option)/CA Hart Data Configuration - - / CA Hart Data Configuration
PED (Option)/PE3 PED X X - - / PE3 PED
Material Certificate (Option)/M01 Material Certificate - - / M01 Material Certification/M11 Material Certificate - - / M11 Material Certification
Pressure Test (Option)/T01 Pressure Test X X X - - / T12 Pressure Test/T04 Pressure Test X X - - / T04 Pressure Test/T09 Pressure Test X X - - / T09 Pressure Test/T12 Pressure Test X X - - / T12 Pressure Test
EXAMPLE: EJA110E - J M S 5 G - 9 2 2 E N / FF1 / HG / M01 / T09 / D1
Model code complete!
PCO-501Original Issue April 20131st Edition April 2013
EJA1
30E
EJA1
10E
EJA1
20E
6
EJA210A StartHere
Transmitter Type (Pressure Type) EJA210E - X X X X X - X X X X X - X X X X X X X X - X / …EJA210A Flange Mounted DP Transmitter EJA210E - S - - W 0 - / Flange Mounted DP Transmitter
Output Signal-D 4 to 20 mA with BRAIN - D - - - / 4 to 20 mA with BRAIN-E 4 to 20 mA with HART 5 - J - - - / 4 to 20 mA with HART 5/7-F FOUNDATION Fieldbus - F - - - / FOUNDATION Fieldbus-G PROFIBUS PA X - - - - / Future Option
Measurement Span (Capsule)M 4 to 400 inH - M - - - / 4 to 400 inHH 20 to 2,000 onH - H - - - / 20 to 2,000 onH
EXAMPLE: EJA210E - J M S 4 G - 9 1 2 E N - W A1 3 B 1 SW B 0 - A / FF1
Continued on next page
PCO-501Original Issue April 20131st Edition April 2013
FM Explosionproof
CSA ExplosionproofEJ
A210
E
/ FF1
/ CF1
8
EJA210A ContinueHere
Painting (Option) EJA210E - X X X X X - X X X X X - X X X X X X X X - X / …/P1 Amp Cover Black - - - - / P1 Amp Cover Black/P2 Amp Cover Jade Green - - - - / P2 Amp Cover Jade Green/P7 Amp Cover Metallic Silver - - - - / P7 Amp Cover Metallic Silver/PR Amp and terminal Cover Red - - - - / PR Amp and terminal Cover Red/X1 Epoxy Paint - - - - / X2 Anti-corrosion coating
Exterior Parts (Option)/HC 316 SST Exterior Parts - - - - / HC 316 SST Exterior Parts
/M03 Material Certificate - - - - / M0W Material Certification/M13 Material Certificate - - - - / M1W Material Certification
Pressure Test (Option)/T31 Pressure Test - - - - / T51 Pressure Test/T32 Pressure Test - - - - / T54 Pressure Test/T36 Pressure Test - - - - / T52 Pressure Test/T37 Pressure Test - - - - / T56 Pressure Test/T38 Pressure Test - - - - / T55 Pressure Test
EXAMPLE: EJA210E - J M S 4 G - 9 1 2 E N - W A1 3 B 1 SW B 0 - A / FF1 / TF1 / D1
Model code complete!
PCO-501Original Issue April 20131st Edition April 2013
EJA2
10E
9
EJA220A .
StartHere
Transmitter Type (Pressure Type) EJA210E - X X X X X - X X X X X - X X X X X X X X - X / …EJA220A Flange Mounted DP Transmitter EJA210E - S - - E 0 - / Flange Mounted DP Transmitter
Output Signal-D 4 to 20 mA with BRAIN - D - - - / 4 to 20 mA with BRAIN-E 4 to 20 mA with HART 5 - J - - - / 4 to 20 mA with HART 5/7-F FOUNDATION Fieldbus - F - - - / FOUNDATION Fieldbus-G PROFIBUS PA X - - - - / Future Option
Measurement Span (Capsule)M 4 to 400 inH - M - - - / 4 to 400 inHH 20 to 2,000 onH - H - - - / 20 to 2,000 onH
EXAMPLE: EJA210E - J M S 4 G - 9 1 2 E N - E A1 3 B 1 SE 0 1 - A / FF1
Continued on next page
PCO-501Original Issue April 20131st Edition April 2013
FM Explosionproof
CSA ExplosionproofEJ
A210
E
/ FF1
/ CF1
11
EJA220A ContinueHere
Painting (Option) EJA210E - X X X X X - X X X X X - X X X X X X X X - X / …/P1 Amp Cover Black - - - - / P1 Amp Cover Black/P2 Amp Cover Jade Green - - - - / P2 Amp Cover Jade Green/P7 Amp Cover Metallic Silver - - - - / P7 Amp Cover Metallic Silver/PR Amp and terminal Cover Red - - - - / PR Amp and terminal Cover Red/X1 Epoxy Paint - - - - / X2 Anti-corrosion coating
Exterior Parts (Option)/HC 316 SST Exterior Parts - - - - / HC 316 SST Exterior Parts
/M04 Material Certificate - - - - / M0E Material Certification/M14 Material Certificate - - - - / M1E Material Certification
Pressure Test (Option)/T31 Pressure Test - - - - / T51 Pressure Test/T32 Pressure Test - - - - / T54 Pressure Test/T36 Pressure Test - - - - / T52 Pressure Test/T37 Pressure Test - - - - / T56 Pressure Test/T38 Pressure Test - - - - / T55 Pressure Test
EXAMPLE: EJA210E - J M S 4 G - 9 1 2 E N - E A1 3 B 1 SE 0 1 - A / FF1 / C1 / D1
Model code complete!
PCO-501Original Issue April 20131st Edition April 2013
EJA2
10E
12
EJA310A, EJA430A, and EJA440AStartHere
Transmitter Type (Pressure Type) EJAxxxE - X X X X X - X X X X X / ….EJA310A Absolute Pressure EJA310E - - / Absolute PressureEJA430A Gauge Pressure EJA430E - - / Gauge PressureEJA440A Gauge Pressure EJA440E - - / Gauge Pressure
Output Signal-D 4 to 20 mA with BRAIN - D - / 4 to 20 mA with BRAIN-E 4 to 20 mA with HART 5 - J - / 4 to 20 mA with HART 5/7-F FOUNDATION Fieldbus - F - / FOUNDATION Fieldbus-G PROFIBUS PA X X X - - / Future Option
Measurement Span (Capsule)L 0.2 to 2.95 inHg X X - L - / 0.2 to 2.95 inHg
M 0.38 to 28 inHg X X - M - / 0.39 to 38 inHgA 4.3 to 430 psi X - A - / 4.3 to 500 psiB 20 to 2,000 psi X - B - / 20 to 2,300 psiC 720 to 4,500 psi X X - C - / 720 to 4,500 psiD 720 to 7,200 psi X X - D - / 720 to 7,200 psi
Wetted Parts MaterialS Hastelloy / 316 SST / 316 SST - S - / Hastelloy / 316 SST / 316 SSTH Hastelloy / Hastelloy / 316 SST X X - H - / Hastelloy / Hastelloy / 316 SSTM Monel / Monel / 316 SST X X - M - / Monel / Monel / 316 SSTT Tantalum / Tantalum / 316 SST X X - T - / Tantalum / Tantalum / 316 SSTA Hastelloy / Hastelloy / Hastelloy X X - A - / Hastelloy / Hastelloy / HastelloyD Tantalum / Hastelloy / Hastelloy X X - D - / Tantalum / Hastelloy / HastelloyB Monel / Monel /Monel X X - B - / Monel / Monel /Monel
Electrical Connection0 G 1/2 - - 0 / G 1/22 1/2 NPT - - 2 / 1/2 NPT 3 Pg 13.5 X X X - - / Not Avialable4 M20 - - 4 / M205 G 1/2 with Plug - - 5 / G 1/2 with Plug7 1/2 NPT with Plug - - 7 / 1/2 NPT with Plug8 Pg 13.5 with Plug X X X - - / Not Avialable9 M20 with Plug - - 9 / M20 with PlugA G 1/2 with 316 SST Plug - - A / G 1/2 with 316 SST PlugC 1/2 NPT with 316 SST Plug - - C / 1/2 NPT with 316 SST PlugD M20 with 316 SST Plug - - D / M20 with 316 SST Plug
DisplayD Display - - D / DisplayE Display with switch - - E / Display with switchN No Display - - N / No Display
Custom Software (Option)/R1 Custom Software X X X - - / Not avialable
Body Options (Option)/N1 No drain or vent plugs - - / N1 No drain or vent plugs/N2 N1 with kidney flange - - / N2 N1 with kidney flange/N3 N2 with material certs - - / N3 N2 with material certs
Wired on Tag (Option)/N4 Wired on Tag - - / N4 Wired on Tag
Low volume cover flange (Option)/N5 For remote seal attachment X X - W - / For remote seal attachment
Fieldbus Options (Option)/LC1 PID Control - - / Standard - no option code required/EE Software Download - - / EE Software Download
Data Configuration (Option)/CA Hart Data Configuration - - / CA Hart Data Configuration
PED (Option)/PED PED X X - - / PE3 PED
Material Certificate (Option)/M01 Material Certificate - - / M01 Material Certification/M11 Material Certificate - - / M11 Material Certification
Pressure Test (Option)/T02 Pressure Test X X - - / T12 Pressure Test/T03 Pressure Test X - - / T01 Pressure Test/T04 Pressure Test X X - - / T04 Pressure Test/T08 Pressure Test X X - - / T08 Pressure Test/T09 Pressure Test X X - - / T09 Pressure Test
EXAMPLE: EJA430E - J B S 5 G - 9 2 2 E N / FF1 / HG / M01 / T09 / D1
Model code complete!
PCO-501Original Issue April 20131st Edition April 2013
EJA4
40E
EJA3
10E
EJA4
30E
15
EJA510A and EJA530AStartHere
Transmitter Type (Pressure Type) EJAxxxE - X X X X X - X X X X X / ….EJA510A Absolute Pressure EJA510E - - / Absolute PressureEJA530A Gauge Pressure EJA530A - - / Gauge Pressure
Output Signal-D 4 to 20 mA with BRAIN - D - / 4 to 20 mA with BRAIN-E 4 to 20 mA with HART 5 - J - / 4 to 20 mA with HART 5/7-F FOUNDATION Fieldbus - F - / FOUNDATION Fieldbus-G PROFIBUS PA X X - - / Future Option
Measurement Span (Capsule)A 1.45 to 29 psi - A - / 1.45 to 29 psiB 14.5 to 290 psi - B - / 14.5 to 290 psiC 72.5 to 1,450 psi - C - / 72.5 to 1,450 psiD 720 to 7,200 psi - D - / 720 to 7,200 psi
Process Connections4 1/2-inch FNPT - 4 - / 1/2-inch FNPT7 1/2-inch MNPT - 7 - / 1/2-inch MNPT8 G 1/2 DIN 16 288 Male - 8 - / G 1/2 DIN 16 288 Male9 M20 x 1.5 DIN 16 288 male - 9 - / M20 x 1.5 DIN 16 288 male
Always NN Always N - N - / Always N
Installation-0 Always 0 - - 0 / Always 0
Electrical Connection0 G 1/2 - - 0 / G 1/22 1/2 NPT - - 2 / 1/2 NPT 3 Pg 13.5 X X - - / Not Avialable4 M20 - - 4 / M205 G 1/2 with Plug - - 5 / G 1/2 with Plug7 1/2 NPT with Plug - - 7 / 1/2 NPT with Plug8 Pg 13.5 with Plug X X - - / Not Avialable9 M20 with Plug - - 9 / M20 with PlugA G 1/2 with 316 SST Plug - - A / G 1/2 with 316 SST PlugC 1/2 NPT with 316 SST Plug - - C / 1/2 NPT with 316 SST PlugD M20 with 316 SST Plug - - D / M20 with 316 SST Plug
DisplayD Display - - D / DisplayE Display with switch - - E / Display with switchN No Display - - N / No Display
BracketE Carbon Steel - - L / 316 SSTF 304 SST - - L / 316 SSTL 316 SST - - L / 316 SSTN None - - N / None
EXAMPLE: EJA530E - J B S 4 N - 0 2 E N /
Continued on next page Determine Amplifier Housing Material code per EJA-E GS to complete model code.
PCO-501Original Issue April 20131st Edition April 2013
EJA5
10E
EJA5
30E
16
EJA510A and EJA530AContinueHere
Agency Approvals (Optional) EJAxxxE - X X X X X - X X X X X / …./FF1 FM Explosionproof - -
/FF15 FM Explosionproof (Fieldbus) - -/FS1 FM Intrinsically Safe - - / FS1 FM Intrinsically Safe
/FS15 FM Intrinsically Safe (Fieldbus) - - / FS15 FM Intrinsically Safe (Fieldbus)/FU1 FM Combo - - / FU1 FM Combo /KF21 ATEX Flameproof - - / KF22 ATEX Flameproof/KS2 ATEX Intrinsically Safe - - / KS21 ATEX Intrinsically Safe