This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
NVLAP Lab Code 500089-0
Test Report Number: PL03403-001 RESTL-R010 Rev D
This report contains data that are not covered by the NVLAP accreditation.
C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6
Linjie Li, Test Engineer Tim Henning, Specialized Testing Manager
NVLAP Lab Code 500089-0
Test Report Number: PL03403-001 RESTL-R010 Rev D
C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6
Page 2 of 12
Product Information
Manufacturer CREE
Model Number (SKU) BXOSQAxx2MES40K
Serial Number PL03403-001
LED Type MDA
Product Description
Gray painted finned metal driver housing. Two circuit boards each with 8 LEDs and one white plastic optic carrier. Backside of the carriers painted black. One clear plastic non-integral optic below each LED.
Driver Information (Where Applicable)
Cree LED Electronic Driver LE098X01
Length Width Height
22” 19” 4”
Sample
The following sample was submitted for evaluation
NVLAP Lab Code 500089-0
Test Report Number: PL03403-001 RESTL-R010 Rev D
C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6
Page 3 of 12
Key Photometric Data Sphere Output Goniophotometer
Luminous Flux 21903 21329.1 lm
Efficacy 99.05 97.01 lm/W
Correlated Color Temperature (CCT) 3777 K
Color Rendering Index (CRI) 70
R9 -21
Duv 0.0014
S/P Ratio* 1.39
Sphere Goniophotometer
Electrical Measurements 120V 277V 120V 277V
Input Wattage 221.12 211.61 219.87 211.51 W
Input Current 1.85 0.79 1.84 0.79 A
Input Voltage 119.65 277.04 120.10 277.05 V
Power Factor 0.997 0.966 0.997 0.967
Off-State Power 0 0 0 0 W
Total Harmonic Distortion (Voltage) 0.07 0.07 0.10 0.08 %
Total Harmonic Distortion (Amperage) 5.38 14.38 5.81 15.10 %
Note: All photometric measurements taken at 120VAC.
Luminous Intensity Distribution Goniophotometer
Max Candela 17650.9 Cd
Angle of Max Candela (Horizontal) 60 ˚
Angle of Max Candela (Vertical) 60 ˚
Key Test Parameters Sphere Output Goniophotometer
Stabilization Time 75 72 min
Total Operating Time (Stabilization + Test) 80 95 min
Ambient Temperature 25.4 24.9 ˚C
NVLAP Lab Code 500089-0
Test Report Number: PL03403-001 RESTL-R010 Rev D
C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6
Page 4 of 12
Chromaticity Coordinates **
x y u v u’ v’ Duv
0.3919 0.3867 0.2286 0.3384 0.2286 0.5076 0.0014
Color Rendering Index Details **
Ra R1 R2 R3 R4 R5 R6 R7 R8 R9 R10 R11 R12 R13 R14
70 69 75 80 72 68 65 78 55 -21 41 68 41 69 88
Chromaticity Diagram **
NVLAP Lab Code 500089-0
Test Report Number: PL03403-001 RESTL-R010 Rev D
C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6
Page 5 of 12
Spectral Distribution **
λ(nm) W/nm λ(nm) W/nm λ(nm) W/nm
360 0.000910 530 0.286082 700 0.052708
370 0.000722 540 0.316450 710 0.039643
380 0.000263 550 0.337087 720 0.030093
390 0.000032 560 0.356156 730 0.022512
400 0.003202 570 0.372377 740 0.016859
410 0.022905 580 0.382089 750 0.012602
420 0.101639 590 0.383182 760 0.009432
430 0.246118 600 0.369878 770 0.007179
440 0.397238 610 0.345613 780 0.005206
450 0.227122 620 0.309952 790 0.003963
460 0.084907 630 0.270050 800 0.002976
470 0.037457 640 0.227075 810 0.002128
480 0.027098 650 0.186680 820 0.001543
490 0.040224 660 0.149955 830 0.001130
500 0.088657 670 0.117009
510 0.164218 680 0.090542
520 0.237228 690 0.069199
Dominant Wavelength ** 579 nm
Peak Wavelength ** 441 nm
Spectral Power Distribution (W/nm) **
NVLAP Lab Code 500089-0
Test Report Number: PL03403-001 RESTL-R010 Rev D
C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6
Page 6 of 12
Zonal Lumen Summary
Zone Lumens % of Total Zone Lumens % of Total
0-5 85.4 0.4% 90-95 0 0%
5-10 276.5 1.3% 95-100 0 0%
10-15 508.6 2.4% 100-105 0 0%
15-20 769.5 3.6% 105-110 0 0%
20-25 1,034.8 4.9% 110-115 0 0%
25-30 1,265.2 5.9% 115-120 0 0%
30-35 1,448.0 6.8% 120-125 0 0%
35-40 1,554.8 7.3% 125-130 0 0%
40-45 1,790.1 8.4% 130-135 0 0%
45-50 2,277.0 10.7% 135-140 0 0%
50-55 2,703.7 12.7% 140-145 0 0%
55-60 2,522.1 11.8% 145-150 0 0%
60-65 2,135.8 10.0% 150-155 0 0%
65-70 1,468.4 6.9% 155-160 0 0%
70-75 893.1 4.2% 160-165 0 0%
75-80 414.9 1.9% 165-170 0 0%
80-85 153.3 0.7% 170-175 0 0%
85-90 27.9 0.1% 175-180 0 0%
Total 21329.1 lm 100%
NVLAP Lab Code 500089-0
Test Report Number: PL03403-001 RESTL-R010 Rev D
C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6
Page 7 of 12
Candela Plot Illuminance Plot
Roadway Utilization Roadway Summary Lumens % Lamp
Cutoff Classification FULL CUTOFF
Distribution TYPE II, SHORT
Downward Street Side 15,764.4 73.9%
Downward House Side 5,564.3 26.1%
Downward Total 21,328.7 100%
Upward Street Side 0 0%
Upward House Side 0 0%
Upward Total 0 0%
Total Lumens 21,328.7 100%
NVLAP Lab Code 500089-0
Test Report Number: PL03403-001 RESTL-R010 Rev D
C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6
Page 8 of 12
Luminaire Classification System
NVLAP Lab Code 500089-0
Test Report Number: PL03403-001 RESTL-R010 Rev D
C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6
ANSI C82.77:2002 Harmonic Emission Limits- Related Power Quality Reqt’s for Lighting Equipment
CIE Pub. 13.3:1995 Method of Measuring and Specifying Color Rendering of Light Sources
CIE Pub. 15:2004 Colorimetry
IES LM-58:1994 Spectroradiometric Measurements
IES LM-65:2001 Single-Ended Compact Fluorescent Lamps – Life Test Performance
IES LM-79:2008 Electrical and Photometric Measurements of Solid-State Lighting Products
Reference Standard Used:
Equipment Description
2m Sphere Tungsten Halogen Omni-Directional 75W Calibration Lamp, Serial Number F119
Type C Goniophotometer and Spectrometer
Tungsten Halogen Omni-Directional 500W Calibration Lamp, Serial Numbers 13C069. 13C070, 13C071. For color calibration of spectrometer, 13C074.
NVLAP Lab Code 500089-0
Test Report Number: PL03403-001 RESTL-R010 Rev D
C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6
Page 12 of 12
Disclaimers:
This report must not be used by the customer to claim product certification, approval or endorsement by NVLAP, NIST or any agency of the federal government.
The results contained in this report pertain only to the tested sample.
This report shall not be reproduced, except in full, without written approval of the CESTL.
Items marked with a single asterisk are not covered by the NVLAP accreditation.
In the event that the recorded temperature is outside of 25 ± 1˚C, this is considered a non-standard condition.
** In the event that testing is subcontracted, test results in this report marked with the symbol **, or noted as
“Sphere” or “Integrating Sphere”, were performed by the subcontracted laboratory identified in the footer on the
first page of this report. Subcontracted testing is strictly integrating sphere based. All other tests are
performed using a Type C goniophotometer.
The integrating sphere information in the equipment list, report items marked with **, or results specifically
identified as “Sphere” or “Integrating Sphere”, are the actual equipment used, and test results produced, by the
subcontracted laboratory when subcontracting is indicated on the cover page.
Additional Comments:
The photos below are intended to show the orientation and fixturing/set-up of the units under test. These
are critical to understanding the results of the test given the sensitivity of many products and
measurement systems to orientation and set-up considerations, and also for reproducing the conditions of