NVLAP Lab Code 500077-0 Test Report Number: PL10405-001A CESTL-R009 Rev D This report contains data that are not covered by the NVLAP accreditation. This report also contains goniometric data that was produced under subcontract by Cree Durham Technology Center, NVLAP Lab Code 500070-0. Cree, Inc | 4600 Silicon Drive | Durham, NC 27703 Page 1 of 15 Report Number: PL10405-001A Model: OSQ-HO-A-xx-5ME-40L-50K-UL Date: 03/25/17 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Chris Strom Cree, Inc 9201 Washington Avenue Racine, WI 53406 Prepared By: Approved By: April Gressel, Photometric Technician Becky Kuebler, Manager Test Engineering
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
NVLAP Lab Code 500077-0
Test Report Number: PL10405-001A CESTL-R009 Rev D This report contains data that are not covered by the NVLAP accreditation. This report also contains goniometric data that was
produced under subcontract by Cree Durham Technology Center, NVLAP Lab Code 500070-0.
C r e e , I n c | 4 6 0 0 S i l i c o n D r i v e | D u r h a m , N C 2 7 7 0 3
Page 1 of 15
Report Number: PL10405-001A
Model: OSQ-HO-A-xx-5ME-40L-50K-UL
Date: 03/25/17
Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation
Report
Prepared For:
Chris Strom
Cree, Inc
9201 Washington Avenue
Racine, WI 53406
Prepared By: Approved By:
April Gressel, Photometric Technician Becky Kuebler, Manager Test Engineering
NVLAP Lab Code 500077-0
Test Report Number: PL10405-001A CESTL-R017 Rev D
C r e e , I n c | 4 6 0 0 S i l i c o n D r i v e | D u r h a m , N C 2 7 7 0 3
Page 2 of 15
Product Information
Manufacturer Cree Inc Model Number (SKU) OSQ-HO-A-xx-5ME-40L-50K-UL Serial Number KL081J59994 LED Type XHP70
Product Description
Brown finned metal housing. Two LED boards each with 13 LEDs. Two white plastic optical carriers. One clear plastic lens below each LED. One black plastic uplight shield attached to each carrier.
Driver Information (Where Applicable)
PHILIPS XI220C105V210CNA1
Length Width Height
30” 22” 4”
Sample
The following sample was submitted for evaluation
NVLAP Lab Code 500077-0
Test Report Number: PL10405-001A CESTL-R017 Rev D
C r e e , I n c | 4 6 0 0 S i l i c o n D r i v e | D u r h a m , N C 2 7 7 0 3
Page 3 of 15
Key Photometric Data Sphere Output Goniophotometer
Luminous Flux 31754.0 30955.8 lm
Efficacy 90.86 88.34 lm/W
Correlated Color Temperature (CCT) 4881 K
Color Rendering Index (CRI) 94
R9 73
Duv 0.000578
S/P Ratio* 2.06 Sphere Goniophotometer
Electrical Measurements 120V 277V 120V 277V
Input Wattage 349.50 344.3 351.03 343.76 W
Input Current 2.92 1.26 2.95 1.26 A
Input Voltage 119.98 277.09 119.05 277.06 V
Power Factor 0.998 .984 0.998 .983
Off-State Power 0 0 0 0 W
Total Harmonic Distortion (Voltage) 0.16 .10 0.13 0.11 %
Total Harmonic Distortion (Amperage) 5.45 12.70 5.48 12.67 %
Note: All photometric measurements taken at 120 VAC.
Luminous Intensity Distribution Goniophotometer
Max Candela 13103.7 Cd
Horizontal Angle of Max Candela 135 ˚
Vertical Angle of Max Candela 70 ˚
Key Test Parameters Sphere Output Goniophotometer
Stabilization Time 120 94 min
Total Operating Time (Stabilization + Test) 120 114 min
Ambient Temperature 24.5 24.1 ˚C
NVLAP Lab Code 500077-0
Test Report Number: PL10405-001A CESTL-R017 Rev D
C r e e , I n c | 4 6 0 0 S i l i c o n D r i v e | D u r h a m , N C 2 7 7 0 3
Distribution Type VS Downward Street Side 15199.3 49.1% Downward House Side 15755.5 50.9% Downward Total 30954.8 100% Upward Street Side 0 0% Upward House Side 0 0% Upward Total 0 0% Total Lumens 30954.8 100%
NVLAP Lab Code 500077-0
Test Report Number: PL10405-001A CESTL-R017 Rev D
C r e e , I n c | 4 6 0 0 S i l i c o n D r i v e | D u r h a m , N C 2 7 7 0 3
Page 8 of 15
Luminaire Classification System **
NVLAP Lab Code 500077-0
Test Report Number: PL10405-001A CESTL-R017 Rev D
C r e e , I n c | 4 6 0 0 S i l i c o n D r i v e | D u r h a m , N C 2 7 7 0 3
ANSI C82.77:2002 Harmonic Emission Limits- Related Power Quality Reqt’s for Lighting Equipment
CIE Pub. 13.3:1995 Method of Measuring and Specifying Color Rendering of Light Sources
CIE Pub. 15:2004 Colorimetry
IES LM-58:1994 Spectroradiometric Measurements
IES LM-79:2008 Electrical and Photometric Measurements of Solid-State Lighting Products
Reference Standard Used:
Equipment Description
3m Sphere Tungsten Halogen Omni-Directional 75W Calibration Lamp, Serial Number G141
Type C Goniophotometer Tungsten Halogen Omni-Directional 500W Calibration Lamp, Serial Number 97A
NVLAP Lab Code 500077-0
Test Report Number: PL10405-001A CESTL-R017 Rev D
C r e e , I n c | 4 6 0 0 S i l i c o n D r i v e | D u r h a m , N C 2 7 7 0 3
Page 14 of 15
Disclaimers:
This report must not be used by the customer to claim product certification, approval or endorsement by NVLAP, NIST or any agency of the federal government.
The results contained in this report pertain only to the tested sample.
This report shall not be reproduced, except in full, without written approval of the CESTL.
* Items marked with a single asterisk are not covered by the NVLAP accreditation.
In the event that the recorded temperature is outside of 25 ± 1˚C, this is considered a non-standard condition.
** In the event that testing is subcontracted, test results in this report marked with the symbol **, or noted as “Goniophotometer”, were performed by the subcontracted laboratory identified in the footer on the first page of this report. Subcontracted testing is strictly goniophotometer based. All other tests are performed using an integrating sphere.
The goniophotometer information in the equipment list, report items marked with **, or results specifically identified as “Goniophotometer”, are the actual equipment used, and test results produced, by the subcontracted laboratory.
Additional Comments:
The photos below are intended to show the orientation and fixturing/set-up of the units under test. These are critical to understanding the results of the test given the sensitivity of many products and measurement systems to orientation and set-up considerations, and also for reproducing the conditions of the test.
Sphere Picture Goniophotometer Picture
NVLAP Lab Code 500077-0
Test Report Number: PL10405-001A CESTL-R017 Rev D
C r e e , I n c | 4 6 0 0 S i l i c o n D r i v e | D u r h a m , N C 2 7 7 0 3
Page 15 of 15
Document Revision History:
Each subsequent revision of this report replaces the preceding report.