Top Banner
COVER 6 & 14 CLADDING Channel cladding with high fire resistance up to B-s3,d0 and invisible fixing for ventilated facades with or without external thermal insulation TECHNICAL DATA SHEET ref BFFT 09/2018-011-EN
35

COVER 6 & 14 CLADDING · 2020. 11. 3. · 60 cm centre-to-centre spacing 10 / m ... sill and causes stains onto the cladding after raining WINDOW SILL Advice : Make a window sill

Mar 07, 2021

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: COVER 6 & 14 CLADDING · 2020. 11. 3. · 60 cm centre-to-centre spacing 10 / m ... sill and causes stains onto the cladding after raining WINDOW SILL Advice : Make a window sill

COVER 6 amp 14 CLADDINGChannel cladding with high fire resistance up to B-s3d0 and invisible fixing

for ventilated facades with or without external thermal insulation

TECHNICAL DATA SHEETref BFFT 092018-011-EN

PRODUCT ADVANTAGES

2

DESIGN amp ENVIRONMENTAL FRIENDLY

LENGTHS AND PROFILES

325 m long and 30 cm wide board 1 sqm per board

4 ribs of 6 cm (COVER 6) 2 ribs of 14 cm (COVER 14) Shadow line width 1 cm

Shadow line depth 2 cm Possible combination of all boards

AESTHETIC The striated surface enhances the light with a change of intensity

throughout the day

Marked slatted look with regular grooving

Invisible fixing

Only 6mm expansion joint at the end of the board

NATURAL Made of VESTAreg a unique Mineral Reinforced Wood Fiber

Contains 75 wood fibres sourced from sustainably managed European

forests

Does not contain any toxic products adhesives coupling agents or heavy

metals

100 French design amp production

Environmental Product Declaration issued by VERITAS

Environmental assessment issued by the Swiss Eco-Bau laboratory

suitable for green building projects (like MINERGIE BREEAM LEED)

Cover 14 2 ribs of 14 cm

Cover 6 4 ribs of 6 cm

RESISTANCE

ACCREDITED Product approval certificates issued by the French

building office (CSTB)

STABLE AND ROT-PROOF

Exceptional dimensional stability with only 15mm

expansion per linear meter over 50degC temperature

variation or 2mmm over 80degC equal to aluminium

Rot-proof does not absorb humidity

100 insect-resistant (including termites)

Stability to UVs stabilisation on the mineral

pigmentrsquos colour

Graffiti and scratches can be easily brushed out or

cleaned off

RATINGS

FIRE REACTION COVER 6 Class B-s3 d0 (EN 13501-12007)

COVER 14

Horizontal installation Class B-s3 d0 (EN 13501-12007)

Vertical installation on metal framework Class B s3 d0 (EN 13501-12007)

on wooden framework Class C s3 d0 (EN 13501-12007)

IMPACT TEST No damages after hard and soft body impact

max impact energy 50kg-130J 3kg-20J 1kg 3J

SEISMIC TEST Highest seismic behaviour following EN 1998 amp Eurocode 8 no risk of falling

boards after static and or dynamic test

WIND LOAD Up to max 237 kN sqm shearing pressure following EN 1991 1-4

with 400mm batten spacing

THERMAL CONDUCTIVITY Low conductivity Lambda von 007 Wmk

Thermal conductivity lower than natural wood

EASY TO INSTALL

FAST amp ACCURATE IMPLEMENTATION

Can be fitted vertically or horizontally on wood or metal

structure

Wide boards of 1sqm for a fast implementation

Fast installation on ventilated batten structure with a 40 to

60cm distance

Interlocking of the boards for guaranteed regular amp parallel

grooves

Fixing by invisible steel hooks screwed into the wood

or metal structures

CORNERS AND DETAILS

Horizontal fitting 45deg mitre-cut for perfect regular corners or

aluminium corner profile with adapted RAL colour

Vertical fitting and soffits aluminium corner profile with

adapted RAL colour

NATURAL COLOURS

Due to the inherent disparities in the standardisation of screens and printing inks the shades depicted onthis sheet may appear slightly different to those of the actual samples

EarthRAL 8019

OceanRAL 7046

SandRAL 1019

HeatRAL 8017

NightRAL 9004

RAL EQUIVALENCESAbove mentioned RAL colours are matching the best to VESTAreg eco-materialrsquos tint but can not be

considered as exactly similar The given indications are informative the responsibility lies with the

customer to determine whether the RAL color fits to its project or doesnrsquot

SunRAL 1011

SIX NATURAL COLOURS TINTED THROUGHOUT WITH MINERAL PIGMENTS(Informative RAL colours for accessories)

AGEING

bull VESTAreg is a natural material composed of wood fibres and mineral pigments giving the colour

bull In the first weeks the fibre will naturally tan and then lighten up to stabilize on the mineral end

colourbull Final patina will be achieved within 10 weeks in average

BOARDS AGEING PROCESS

The final patina will be obtained within 10 weeks the fibre will naturally tan and lighten up to reach the mineral pigmentrsquos tint

NIG

HT

OC

EacuteAN

SAN

DSU

NH

EAT

Day 1 Installation After 10 weeks

EAR

TH

PROFILES amp ACCESSORIES

References Products Profiles Dimension

BF4O325O5 Cover 6 - 4 waves Ocean

BF4O325H5 Cover 6 - 4 waves Heat

BF4O325S5 Cover 6 - 4 waves Sand

BF4O325U5 Cover 6 - 4 waves Sun

BF4O325N5 Cover 6 - 4 waves Night

BF4O325E5 Cover 6 - 4 waves Earth

BF2O325O5 Cover 14 - 2 waves Ocean

BF2O325H5 Cover 14 - 2 waves Heat

BF2O325S5 Cover 14 - 2 waves Sand

BF2O325U5 Cover 14 - 2 waves Sun

BF2O325N5 Cover 14 - 2 waves Night

BF2O325E5 Cover 14 - 2 waves Earth

CORNER PROFILEReferences Products Profiles Dimension

BAPA300O1 Aluminium Corner - pack of 2 pcs Ocean

BAPA300H1 Aluminium Corner - pack of 2 pcs Heat

BAPA300S1 Aluminium Corner - pack of 2 pcs Sand

BAPA300U1 Aluminium Corner - pack of 2 pcs Sun

BAPA300N1 Aluminium Corner - pack of 2 pcs Night

BAPA300E1 Aluminium Corner - pack of 2 pcs Earth

PIERCED STARTING PROFILEReferences Products Profiles Dimension

BAPD300A1 Pack of 5 Aluminium profiles - 2 mm thickness

300 x 43 x 4 cm(L x W x H)

Colours

COVER 6 amp COVER 14Colours

Colours

Neutral

325 x 30 x 285 cm(L x W x H)

1 pcs = 0975 sqm

325 x 30 x 285 cm(L x W x H)

1 pcs = 0975 sqm

300 x 6 x 6 cm(L x W x H)

FIXINGS

Number of hooks msup2 COVER 614

60 cm centre-to-centre spacing 10 msup2

40 cm 60 cm centre-to-centre spacing 15 msup2

FIXING HOOKSReferences Products Profiles Dimension

BFCR1PI2 Fixing Hook (50 units per bag) Stainless steel 37 x 19 x 15 cm(L x W x H)

A2 STAINLESS STEEL SCREWReferences

VIS BA RAL ndeg

VIS ME RAL ndeg Bi-metal Steel screw tinted head - Box of 500 units

48 x 21mm - Inox A2 A2 stainless steel

Wood amp Alu screw tinted head - Box of 500 units

42 x 32mm - Inox A2 A2 stainless steel

Colours

Products colours

RAL color

RAL color

- Ocean 7046 - Heat 8017- Sand 1019 - Sun 1011- Night 9004 - Earth 8019

- Ocean 7046 - Heat 8017- Sand 1019 - Sun 1011- Night 9004 - Earth 8019

VIS INOX A2 - A2 STAINLESS STEEL SCREW

VIS BA NdegRAL Laqueacutee RALRAL color

16 x 11 x 7 cm(L x l x H L x W x H ) 15kg

VIS ME NdegRAL Laqueacutee RALRAL color

16 x 11 x 7 cm(L x l x H L x W x H ) 15kg

Reference Profiles Dimcm Weight in kgProduct

Wood amp Alu screw tinted head - Box of 500 units

42 x 32mm - Inox A2 A2 stainless steel

Bi-metal Steel screw tinted head - Box of 500 units

48 x 21mm - Inox A2 A2 stainless steel

- Ocean 7046 - Heat 8017- Sand 1019 - Sun 1011- Night 9004 - Earth 8019

- Ocean 7046 - Heat 8017- Sand 1019 - Sun 1011- Night 9004 - Earth 8019

4kg

4kg

INSTALLATIONKEY PRINCIPLES

10

IMPLEMENTATION ON EXTERNAL THERMAL INSULATION

Horizontal fitting

Vertical fitting

TIMBER FRAME OR MASONRY (CONCRETE BRICKhellip) WALL WITH WOOD OR METAL BATTENS

Timber frame wall

Concrete wall

Timber frame wall

Concrete wall

Insulation

Insulation

IMPORTANT

Ensure the cladding is installedon ventilated battens minimumcross-section of wooden battens27x40 mm

Centre-to-centre spacing of 400to 600 mm depending on theimplementation area requiredlayout wind force or buildingheight

This batten framework can befixed on each wall type (woodmetal concrete etc) with orwithout exterior insulation

In all cases a minimum air gap of2 cm is required behind thecladding (check local regulations)

IMPLEMENTATION ON LINER TRAYS (INDUSTRIAL BUILDING ENVELLOPE)

Horinzontal fitting

IMPORTANT

Ensure the cladding is installed onventilated battens minimum cross-section of metal battens 20 x 40 mm

Centre-to-centre spacing of 400 to600 mm depending on theimplementation area required layout wind force or building height

This batten framework can be fixedon each wall type (wood metalconcrete etc) with or without exteriorinsulation

In all cases a minimum air gap of 2cm is required behind the cladding(check local regulations)

Steelstructure

Liner trays

Vertical fitting

Insulation

Insulation

Steelstructure

Liner trays

REMARQUES IMPORTANTES SUR LA POSE

BOARD PREPARATION Length 325 cm (tolerance of +0 20 mm)

Width 320 mm visible width when installed = 300mm (tolerance of plusmn 255 mm)

Thickness 285 mm (tolerance of plusmn 115 mm)

Squaring has to be done on site

Boards have to be calibrated according to layout

START Vertical installation Start with a metal or Aluminium profile It is highly recommended to install all the

boards in the same orientation in order to obtain a uniform colour Indeed the random brushing

creates an effect on the surface that capture the lights differently according the boards orientation

Pose horizontale Boards have to be installed with the groove at the bottom and the tongue at the top

IMPORTANT NOTICES

All instructions concerning the installation of our cladding are to be followed

Assembly errors are not covered by the NEOLIFEreg guarantee

An approved fitter shall be able to assess the construction conformity to the local

professional installation guidelines

Groove at the bottom

Horizontal intallation

Tongue at the top

Verticalinstallation

Profil alu de deacutepart visseacute

Screwed aluminium starting profile

REMARQUES IMPORTANTES SUR LA POSE

ALWAYS KEEP A 6 MM EXPANSION JOINT

A minimum space of 6mm between the 325m boards

and contiguous elements (joinery wall other cladding

boards) should be left to enable the natural expansion

of the NEOLIFEreg cladding boards

Always maintain 15 mm expansion per linear meter

(or 2mm in case of high temperature variations)

IMPORTANT NOTICES

NOT FOR STRUCTURAL USE Under no circumstances should the cladding boards be used for load-bearing or structural purposes

The professional rules and recommendations governing the cladding installation must be followed

NO SEALING PROPERTIES The boards are not designed to ensure the watertightness of the external facade

They should be used with a rainscreen wherever itrsquos required which will provide the weatherproofing

element in compliance with the local Building Regulations

FIXING ADDITIONAL ITEMS TO THE FACADE The cladding is not load-bearing

Anything fixed to the facade must be attached to the supporting structure behind the cladding

6mm

CAUTIONThe specifications and recommendations given in the NEOLIFEreg installation guide available at

wwwneolife-solutionscom website are not a substitute to regulations concerning safety

environment and regulatory installation specifications

REMARQUES IMPORTANTES SUR LA POSEIMPORTANT NOTICES

The panels have always to be fixed on each end at less than 1 cm of the boardrsquos edge

both in horizontal and vertical installations

EPDM strip

Concrete wall

1 Batten min size 60mmOr 2 battens min size 27x40mm

6 mm expansion joint

PREPARATION OF THE STRUCTURE

CAUTION

Make sure to respect the cladding installation steps recommended by the local professional guidelines

IMPORTANT ADVICES

The supporting structure (wood or metal) has to be perfectly flat to get a perfect facade The installation has to be planned on a ventilated wood structure with a minimum batten size of

27x40mm or on omega metal profiles 30x30x30 with a 400 ou 600 mm centre to centre distance

following the buildingrsquos category and height

The supporting structure can be fitted on every kind of walls (wood metal concrete) with or without

external insulation

Always keep a minimum 2cm air gap for ventilation behind the cladding (check the

recommendations of the local regulations )

The supporting structure has to be placed perpendicular to the cladding For vertical installation

the ventilation will be enabled through the claddingrsquos ribs or thanks to a crossed structure (following

the local recommendations)

Wide board With 300 mm width

KEY INSTALLATION PRINCIPLES

Mitre cut with perfectly aligned grooving

Horizontal or vertical fitting with various layouts

Invisible fixing using steel hooks screwed into the wood or metal supporting structures

Fast fixing using screwed steel hooks

NEOLIFEreg COVER claddingcan be fitted using all the conventional facade and covering accessories

Vertical fitting with a corner profile

6mm open expansion gapat the end of the board

Horizontal fittingwith a mitre cut

or with a corner profile

Metal CopingWindow revealwith metal profile

Outside corner or window reveal with Neolife corner profile

KEY INSTALLATION PRINCIPLES

DESIGN GUIDELINES

When the sign is installed onto the claddingwith no water runoff possibility It will cause stains on the claddingwhen drying (due to the mix of dust andpollution)

Flat metall elements without watertightnessmanagement Dirty water runoff causes stains

Advice

Leave space between cladding and the signand fix it on the load-bearing wall

INSTALLATION OF SHOP SIGN

OTHERS

Sign stuck onto the wall Sign away from the wall

Advice Install the element before the cladding bymanaging the waterlightness against the wallPlan a 10 slope and a waterdrop in order toavoid a water runoff onto the cladding

infiltration Seal and fixing

Cutting for expansion

Flat Casquette

Fixing againstthe wall

Absence of water drop Water drop

DESIGN GUIDELINES

BEST PRACTICEFind all the best practices in the NEOLIFEreg installation guide

available on our website wwwneolife-solutionscom

Closed metal profile at the junction betweencladding render no water runoffpossibility risk of stains and moisture on thestructure no ventilation

Flat window sill without water drop Dust and pollution collects on the windowsill and causes stains onto the cladding afterraining

WINDOW SILL

Advice Make a window sill with a 10 slopeminimum and a water drop with 30 mm gapfrom the cladding

Flat metal window sill

30mm

Advice Use a perforated metal ending profile and raise the cladding boards 5mm above the profile

no ventilation

Visible screwWater storage

Hidden screw

Perforated closure profile ventilation and water runoff

5mm

ENDINGS JUNCTIONS

Absence of water drop Water drop

REMARQUES IMPORTANTES SUR LA POSECAUTION

THE FULL INSTALLATION MANUAL OF COVER CLADDING PANELS IS AVAILABLE AT

wwwneolife-solutionscom

NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters

disposal for any clarifications concerning the installation procedure of its products

The specifications and recommendations given in the installation guide are not a

substitute to regulations concerning safety environment and professional regulatory

dispositions

All instructions concerning the installation of our cladding are to be followed

Assembly errors are not covered by the NEOLIFEreg guarantee

An approved fitter shall be able to assess the construction conformity to the local

professional installation guidelines

MAINTENANCE

21

Depending on the boards dirt after implementation (presence of mud dust etchellip) especially in the

grooves rain stains can appear on the surface

NEOLIFE strongly recommend to clean the boards after implementation with a pressure

washer following the boardsrsquo orientation (distance of min 20cm from the board DO NOT

USE a rotary nozzle)

Recommendations

Do not forget to clean the window shelves as well avoiding so any risk of dust stains on the

cladding after the first rain (windows are frequently dusty during construction)

All metal joineries (windows parapet capping etchellip) have to have a drip-edge flashing in

order to limit the water runoff on the cladding Shop signs or any other elements installed on

the cladding have to be moved forward (space left between cladding and the element) to

avoid any stains

Caution

If any operation involving the use of asphalt or concrete occurs after facade completion

NEOLIFE recommend to protect the cladding with a plastic cover in order to avoid stains

Indeed if not protected a greasy steam can spread on the surface and in the grooves In that

case a grease-removing product will be needed to clean the boards and all the surrounding

elements

BUILDING SITE CLEANING

LONG LASTING

VERY LIMITED MAINTENANCE

The material does not require any wood preservative (oils varnishes saturators hellip)

bull The VESTAreg material is naturally equivalent to use class 4(service environment In contact with ground or fresh water amp Permanently exposed to wetting The use classes rank the risk of exposure to decay and insect attack for differing in service environments according to EN 335 ndash 2)

bull Highly hydrophobic and rot-proof no algae fungi or moss development

bull Insect-resistant does not require any treatments against termites

STAIN REMOVAL

STAINS

Tanin stains

During the first weeks after installation tannin rings may occur because of the rain especially

on claddings with a light colour They will be washed off and fade during the next rain to

lessen until they completely disappear Be careful not to mistake these stains with dust or

pollution stains which appear on all cladding types

Bleach-based cleaning products

Slight discolouration Clean with water and complete if needed with slight brushing in the

boards orientation

Graffities oil paint and ink

Use a specialised stain remover (ex laquo STG 105 BIO raquo de STG)

Bitumen grease

Use a specialised stain remover (ex laquo Scalp Aqua 03 raquo)

Oxidation stains after contact with a corroded metal

Use a specialised wood de-greyer (ex laquo Scalp Neutral DA 66 raquo)

Caution

- Analyse properly the substance to clean so to use the right stain removing product

- Always test the stain removing product on a small and discrete surface before cleaning the

entire board

- It is mandatory that you analyse on a long time scale (and after exposure to Uvs) that the

solution you choose will not react with the cladding and therefore produce unsightly effects

DAMAGES

bull Scratches cigarette marks abrasion Brush away with a brass brush (lengthways)

TECHNICAL CHARACTERISTICS

25

SYSTEM PERFORMANCES

DESIGNATIONTEST

METHODS amp STANDARDS

CLADDING OUTLIFE COVER 6 amp 14

WIND LOAD (Depression) COVER 6 (4 ribs) COVER 14 (2 ribss)

Fixings description Eurocodes EN 1991-1-4 Test results Maximum shearing

pressure Test results Maximum shearingpressure

Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction

4 900 Pa

(degradation)140 kNm2 5 200 Pa

(degradation) 148 kNm2

Maximum 400mm centre-to-centre support spacing with one fixing tab at every junction 8 300 Pa (ruine) 237 kNm2 8 300 Pa (ruine) 237 kNm2

IMPACT RESISTANCE COVER 6 (4 ribs) COVER 14 (2 ribs)

Fixings description NF P 08302 Test results Test results

Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction

No damage with the impact energies below

Soft impacts 50Kg 130J

Soft impacts 3Kg 20J

Hard impacts 1Kg 3J

No damage with the impact energies below Soft impacts 50Kg 130J

Soft impacts 3Kg 20JHard impacts 1Kg 3J

SEISMIC RESISTANCE COVER 6 amp14

COVER 6 amp 14can be installed in seismic zones and buildings according to the following details

Highest seismic behaviour following Eurocode 8 no risk of falling boards or permanent deformations after static and dynamic test

FIRE RESISTANCE COVER 6 COVER 14

Tests description EN 13823 et EN 13501-12007

Fire rating

(on A2-s1d0 wall)

Fire rating

(on A2-s1d0 wall)

SBI test carried out on 3 models forming a 1500mm high 1000mm long and 500mm wide

dihedral wedge Assembly on air board and horizontal wood batten Valable contre un

substrat A2-s1d0

B-s3d0

Equivalent UK class 0

FIGRA average 1151Ws

THR average 6MJ

SMOGRA average 371 m2s2

B-s3d0

Equivalent UK class 0

FIGRA average 1924Ws

THR average 112MJ

SMOGRA average 592m2s2

Horizontal installation Class B-s3 d0 - Vertical installation on metal framework Class B s3 d0 on wooden framework Class C s3 d0 (EN 13501-12007)

PHYSICAL AND MECHANICAL FEATURES

DESIGNATION TEST METHODES amp STANDARDS COVER 6 amp 14 OUTLIFE CLADDING

FLAMMABLE MASS COVER 6 COVER 14Tests description NF EN 13238 Flammable mass per sqm (MJ)Tests realised according to the crucible method on at least 5 product samples 334 MJ 285 MJ

APPEARANCE DURABILITY(ageing under QUV) COVER 6 amp 14

Test descriptionNF EN 927-6 (2006)

FCBA‐ LBO6-PHY‐001

Test results

Artificial ageing test under QUV allowing an assessment of durability and decorative

properties modification Total duration 10 weeks comprising

condensation UV radiation and water spray phases

Stable products according to the EN 927-2

No blistering defects are observed according to ISO 4628-2 standard Resultt 0No cracking defects are observed according to ISO 4628-4 standard Result 0No flaking defects are observed according to ISO 4628-5 standard Result 0

THERMAL EXPANSION COVER 6 amp 14

Test description

ISO 11359-2 adapted to

FCBA - LBO6PHY-001

Test results

Thermodilatometric test in climatic room going from -20deg to +60deg to determine the profils

thermal expansion coefficient in solid state

Coefficient de dilatation thermique moyen

Longitudinally δL = 380 degK-1 10-6 standard spacing 210 degK-1 10-6 For uninstalled boardsTransversally δB = 575 degK-1 10-6 standard spacing 211 degK-1 10-6 For uninstalled boards

WATER UPTAKE DETERMINATION COVER 6 amp 14

Test description FCBA‐LBO‐MECA‐014 Test results

Water uptake determination after immersion in cold water during 28 days Measure of the

mass in its initial state and after 124714 et 28 days

Boards suitable to use in class 4 (Wood use class NF EN 335-2)Boards naturally resistant against fungus and soft rotAverage water uptake after 28 days 803Water content at 28 days and imputed to the cellulosic matter 143

ELASTICITY CONSTRAINS AND MODULE IN FLEXION COVER 6 amp 14

Test description

FCBA‐LBO‐MECA‐008

NF EN 310 modifiedWPC profiles

Test results

3 point flexion under normal conditions 20degCand 65 RH

Eaverage = 904 Nmm2fm = 40 Nmm2

ENVIRONMENTAL CHARACTERISTICS

28

VESTAreg ECO-MATERIAL

VESTAreg (Vegetal Ecological Stable Timber

Advantage) is an innovative and eco-friendly compound

with exceptional properties It was developed by

NEOCOreg NEOLIFEreglsquos Research Centre specialising in

green technologies in partnership with European experts

EXCEPTIONAL WOOD FIBER CONTENTVESTAreg revolutionises eco-materials and the design of

environmental solutions for construction projects and the

landscaping of outside spaces It finally brings a response

to the architects landscapers and design officesrsquo

demands working on eco-construction and sustainable

development projects

ECO-FRIENDLYThe wood fibres contained in VESTAreg come exclusively

from sawmills offcuts the wood coming from sustainably

managed European forests The production of our material

does not require the cutting of any trees and does not use treated wood from recycled pallets Moreover

NEOLIFE does not use any toxic additives in the production process of the material

VESTAreg is 100 recyclable with a perfect traceability it only contains virgin substances (no recycled

components for which establishing a traceability is impossible)

CLEANDoes not contain solvents adhesives or phthalates and does not generate

toxic emissions

STABLE AND RESISTANTVESTAreg fibres benefit from a thermal treatment which provides hydrophobic properties to the material The

formula reinforced with mineral resin lignin and antioxidants enables a remarkable mechanical resistance as

well as an outstanding design

The mineral pigments also offer a strong resistance to UV rays making the colours more durable whatever the

exposure

SOURCE

Raw material VESTAreg

X-FIRE is highly fire-resistant Wood fibres coming from sustainably managed European forests

Board Production France

COMPOSITIONby Volume 75 wood fibres mineral oil mineral salts mineral pigments

PHYSICAL PROPERTIES

Mass sqm COVER 6 195 kgmsup2 COVER 14 165 kgmsup2

Density 1500 kgm3

Parasite resistance Equivalent to use class 4 No development of fungal rot mosses or mould Insect-resistant including termites

Surface appearance Micro-striated surface splinter free blisters or flakes off Maintenance-free

Scratches resistance Equivalent to natural wood - Brushing possible without discolouration

Thermal inertia Low thermal inertia due to the high wood fibres content

ENVIRONMENTAL PROPERTIES

Recycling 100 recyclable 75 renewable and combustible (75 biomass)

Toxic substances Contains no toxic or dangerous products (according to Reach Regulation EC19072006)

Chemical fire retardant substance None

Solvents None

Heavy metals None lead-and mercury-free stabilization

Phthalates adhesives None

Formaldehydes and VOCs Lower than or equal to natural wood

VESTAreg REINFORCED WOOD FIBER

VESTA X-FIRE

ENVIRONMENTAL PRODUCT DECLARATION

1 - Values describing the environmental impacts

Owner of the declaration NEOLIFE Editor BUREAU VERITAS CODDE Declaration reference DEP_NEOLIFE_COVER_201507

Publication 10072015 Validity 10072020

Complies with the standard ISO 14025 NF EN 15804+A1 And itrsquos national addendum X P01-064CN

Environmental Declaration of the COVER productavailable on request

ENVIRONMENTAL PRODUCT DECLARATION

2 ndash Values describing the use of primary energetic sources other resources and water

3 ndash Complementary values describing the outflows

FURTHER DETAILS

33

TECHNICAL DESCRIPTION

French accreditaion type laquo Avis Technique Expeacuterimental de Type A raquo issued by CSTB (France)

Ndeg2278 ndash Available at httpevaluationcstbfrrechercherproduits-evaluesprestations=atex

VESTA Reinforced Wood Fiber cladding containing at least 75 wood fibres

Boards with a slatted aspect featuring 6 cm or 14 cm ribs

Fire rating with natural mineral salts following EN 13501-12007

COVER 6 B-s3-d0 minimum

COVER 14 B-s3-d0 minimum

Invisible fixing with stainless steel hooks screwed into wood or metal battens

Fast and accurate fitting thanks to the interlocking board system

Outside corners catered for by using 45deg miter cuts or aluminium corner profile

Dimensional stability of maximum 2mm m over ∆80degC

rot-proof not sensitive to moss and mould

Insect-resistant termites included

Stable colors after natural patina is acquired

Contact us to get the full technical specification sheet

CONTACT

CAUTION

This technical sheet is associated with the technical installation guide of CLAD claddingboard available at wwwneolife-solutionscom

NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters

disposal for any clarifications concerning the installation procedure of its products

The specifications and recommendations given in the installation guide are not a

substitute to regulations concerning safety environment and professional regulatory

dispositions

All instructions concerning the installation of our cladding are to be followed

Assembly errors are not covered by the NEOLIFEreg guarantee

An approved fitter shall be able to assess the construction conformity to the local

professional installation guidelines

304 Route Nationale 6 ndash Celtic Parc Bacirctiment Avalon II - 69760 Limonest FranceTel +33 (0)4 78 25 63 08 ndash Fax +33 (0)4 72 29 29 47

wwwneolife-solutionscom

Page 2: COVER 6 & 14 CLADDING · 2020. 11. 3. · 60 cm centre-to-centre spacing 10 / m ... sill and causes stains onto the cladding after raining WINDOW SILL Advice : Make a window sill

PRODUCT ADVANTAGES

2

DESIGN amp ENVIRONMENTAL FRIENDLY

LENGTHS AND PROFILES

325 m long and 30 cm wide board 1 sqm per board

4 ribs of 6 cm (COVER 6) 2 ribs of 14 cm (COVER 14) Shadow line width 1 cm

Shadow line depth 2 cm Possible combination of all boards

AESTHETIC The striated surface enhances the light with a change of intensity

throughout the day

Marked slatted look with regular grooving

Invisible fixing

Only 6mm expansion joint at the end of the board

NATURAL Made of VESTAreg a unique Mineral Reinforced Wood Fiber

Contains 75 wood fibres sourced from sustainably managed European

forests

Does not contain any toxic products adhesives coupling agents or heavy

metals

100 French design amp production

Environmental Product Declaration issued by VERITAS

Environmental assessment issued by the Swiss Eco-Bau laboratory

suitable for green building projects (like MINERGIE BREEAM LEED)

Cover 14 2 ribs of 14 cm

Cover 6 4 ribs of 6 cm

RESISTANCE

ACCREDITED Product approval certificates issued by the French

building office (CSTB)

STABLE AND ROT-PROOF

Exceptional dimensional stability with only 15mm

expansion per linear meter over 50degC temperature

variation or 2mmm over 80degC equal to aluminium

Rot-proof does not absorb humidity

100 insect-resistant (including termites)

Stability to UVs stabilisation on the mineral

pigmentrsquos colour

Graffiti and scratches can be easily brushed out or

cleaned off

RATINGS

FIRE REACTION COVER 6 Class B-s3 d0 (EN 13501-12007)

COVER 14

Horizontal installation Class B-s3 d0 (EN 13501-12007)

Vertical installation on metal framework Class B s3 d0 (EN 13501-12007)

on wooden framework Class C s3 d0 (EN 13501-12007)

IMPACT TEST No damages after hard and soft body impact

max impact energy 50kg-130J 3kg-20J 1kg 3J

SEISMIC TEST Highest seismic behaviour following EN 1998 amp Eurocode 8 no risk of falling

boards after static and or dynamic test

WIND LOAD Up to max 237 kN sqm shearing pressure following EN 1991 1-4

with 400mm batten spacing

THERMAL CONDUCTIVITY Low conductivity Lambda von 007 Wmk

Thermal conductivity lower than natural wood

EASY TO INSTALL

FAST amp ACCURATE IMPLEMENTATION

Can be fitted vertically or horizontally on wood or metal

structure

Wide boards of 1sqm for a fast implementation

Fast installation on ventilated batten structure with a 40 to

60cm distance

Interlocking of the boards for guaranteed regular amp parallel

grooves

Fixing by invisible steel hooks screwed into the wood

or metal structures

CORNERS AND DETAILS

Horizontal fitting 45deg mitre-cut for perfect regular corners or

aluminium corner profile with adapted RAL colour

Vertical fitting and soffits aluminium corner profile with

adapted RAL colour

NATURAL COLOURS

Due to the inherent disparities in the standardisation of screens and printing inks the shades depicted onthis sheet may appear slightly different to those of the actual samples

EarthRAL 8019

OceanRAL 7046

SandRAL 1019

HeatRAL 8017

NightRAL 9004

RAL EQUIVALENCESAbove mentioned RAL colours are matching the best to VESTAreg eco-materialrsquos tint but can not be

considered as exactly similar The given indications are informative the responsibility lies with the

customer to determine whether the RAL color fits to its project or doesnrsquot

SunRAL 1011

SIX NATURAL COLOURS TINTED THROUGHOUT WITH MINERAL PIGMENTS(Informative RAL colours for accessories)

AGEING

bull VESTAreg is a natural material composed of wood fibres and mineral pigments giving the colour

bull In the first weeks the fibre will naturally tan and then lighten up to stabilize on the mineral end

colourbull Final patina will be achieved within 10 weeks in average

BOARDS AGEING PROCESS

The final patina will be obtained within 10 weeks the fibre will naturally tan and lighten up to reach the mineral pigmentrsquos tint

NIG

HT

OC

EacuteAN

SAN

DSU

NH

EAT

Day 1 Installation After 10 weeks

EAR

TH

PROFILES amp ACCESSORIES

References Products Profiles Dimension

BF4O325O5 Cover 6 - 4 waves Ocean

BF4O325H5 Cover 6 - 4 waves Heat

BF4O325S5 Cover 6 - 4 waves Sand

BF4O325U5 Cover 6 - 4 waves Sun

BF4O325N5 Cover 6 - 4 waves Night

BF4O325E5 Cover 6 - 4 waves Earth

BF2O325O5 Cover 14 - 2 waves Ocean

BF2O325H5 Cover 14 - 2 waves Heat

BF2O325S5 Cover 14 - 2 waves Sand

BF2O325U5 Cover 14 - 2 waves Sun

BF2O325N5 Cover 14 - 2 waves Night

BF2O325E5 Cover 14 - 2 waves Earth

CORNER PROFILEReferences Products Profiles Dimension

BAPA300O1 Aluminium Corner - pack of 2 pcs Ocean

BAPA300H1 Aluminium Corner - pack of 2 pcs Heat

BAPA300S1 Aluminium Corner - pack of 2 pcs Sand

BAPA300U1 Aluminium Corner - pack of 2 pcs Sun

BAPA300N1 Aluminium Corner - pack of 2 pcs Night

BAPA300E1 Aluminium Corner - pack of 2 pcs Earth

PIERCED STARTING PROFILEReferences Products Profiles Dimension

BAPD300A1 Pack of 5 Aluminium profiles - 2 mm thickness

300 x 43 x 4 cm(L x W x H)

Colours

COVER 6 amp COVER 14Colours

Colours

Neutral

325 x 30 x 285 cm(L x W x H)

1 pcs = 0975 sqm

325 x 30 x 285 cm(L x W x H)

1 pcs = 0975 sqm

300 x 6 x 6 cm(L x W x H)

FIXINGS

Number of hooks msup2 COVER 614

60 cm centre-to-centre spacing 10 msup2

40 cm 60 cm centre-to-centre spacing 15 msup2

FIXING HOOKSReferences Products Profiles Dimension

BFCR1PI2 Fixing Hook (50 units per bag) Stainless steel 37 x 19 x 15 cm(L x W x H)

A2 STAINLESS STEEL SCREWReferences

VIS BA RAL ndeg

VIS ME RAL ndeg Bi-metal Steel screw tinted head - Box of 500 units

48 x 21mm - Inox A2 A2 stainless steel

Wood amp Alu screw tinted head - Box of 500 units

42 x 32mm - Inox A2 A2 stainless steel

Colours

Products colours

RAL color

RAL color

- Ocean 7046 - Heat 8017- Sand 1019 - Sun 1011- Night 9004 - Earth 8019

- Ocean 7046 - Heat 8017- Sand 1019 - Sun 1011- Night 9004 - Earth 8019

VIS INOX A2 - A2 STAINLESS STEEL SCREW

VIS BA NdegRAL Laqueacutee RALRAL color

16 x 11 x 7 cm(L x l x H L x W x H ) 15kg

VIS ME NdegRAL Laqueacutee RALRAL color

16 x 11 x 7 cm(L x l x H L x W x H ) 15kg

Reference Profiles Dimcm Weight in kgProduct

Wood amp Alu screw tinted head - Box of 500 units

42 x 32mm - Inox A2 A2 stainless steel

Bi-metal Steel screw tinted head - Box of 500 units

48 x 21mm - Inox A2 A2 stainless steel

- Ocean 7046 - Heat 8017- Sand 1019 - Sun 1011- Night 9004 - Earth 8019

- Ocean 7046 - Heat 8017- Sand 1019 - Sun 1011- Night 9004 - Earth 8019

4kg

4kg

INSTALLATIONKEY PRINCIPLES

10

IMPLEMENTATION ON EXTERNAL THERMAL INSULATION

Horizontal fitting

Vertical fitting

TIMBER FRAME OR MASONRY (CONCRETE BRICKhellip) WALL WITH WOOD OR METAL BATTENS

Timber frame wall

Concrete wall

Timber frame wall

Concrete wall

Insulation

Insulation

IMPORTANT

Ensure the cladding is installedon ventilated battens minimumcross-section of wooden battens27x40 mm

Centre-to-centre spacing of 400to 600 mm depending on theimplementation area requiredlayout wind force or buildingheight

This batten framework can befixed on each wall type (woodmetal concrete etc) with orwithout exterior insulation

In all cases a minimum air gap of2 cm is required behind thecladding (check local regulations)

IMPLEMENTATION ON LINER TRAYS (INDUSTRIAL BUILDING ENVELLOPE)

Horinzontal fitting

IMPORTANT

Ensure the cladding is installed onventilated battens minimum cross-section of metal battens 20 x 40 mm

Centre-to-centre spacing of 400 to600 mm depending on theimplementation area required layout wind force or building height

This batten framework can be fixedon each wall type (wood metalconcrete etc) with or without exteriorinsulation

In all cases a minimum air gap of 2cm is required behind the cladding(check local regulations)

Steelstructure

Liner trays

Vertical fitting

Insulation

Insulation

Steelstructure

Liner trays

REMARQUES IMPORTANTES SUR LA POSE

BOARD PREPARATION Length 325 cm (tolerance of +0 20 mm)

Width 320 mm visible width when installed = 300mm (tolerance of plusmn 255 mm)

Thickness 285 mm (tolerance of plusmn 115 mm)

Squaring has to be done on site

Boards have to be calibrated according to layout

START Vertical installation Start with a metal or Aluminium profile It is highly recommended to install all the

boards in the same orientation in order to obtain a uniform colour Indeed the random brushing

creates an effect on the surface that capture the lights differently according the boards orientation

Pose horizontale Boards have to be installed with the groove at the bottom and the tongue at the top

IMPORTANT NOTICES

All instructions concerning the installation of our cladding are to be followed

Assembly errors are not covered by the NEOLIFEreg guarantee

An approved fitter shall be able to assess the construction conformity to the local

professional installation guidelines

Groove at the bottom

Horizontal intallation

Tongue at the top

Verticalinstallation

Profil alu de deacutepart visseacute

Screwed aluminium starting profile

REMARQUES IMPORTANTES SUR LA POSE

ALWAYS KEEP A 6 MM EXPANSION JOINT

A minimum space of 6mm between the 325m boards

and contiguous elements (joinery wall other cladding

boards) should be left to enable the natural expansion

of the NEOLIFEreg cladding boards

Always maintain 15 mm expansion per linear meter

(or 2mm in case of high temperature variations)

IMPORTANT NOTICES

NOT FOR STRUCTURAL USE Under no circumstances should the cladding boards be used for load-bearing or structural purposes

The professional rules and recommendations governing the cladding installation must be followed

NO SEALING PROPERTIES The boards are not designed to ensure the watertightness of the external facade

They should be used with a rainscreen wherever itrsquos required which will provide the weatherproofing

element in compliance with the local Building Regulations

FIXING ADDITIONAL ITEMS TO THE FACADE The cladding is not load-bearing

Anything fixed to the facade must be attached to the supporting structure behind the cladding

6mm

CAUTIONThe specifications and recommendations given in the NEOLIFEreg installation guide available at

wwwneolife-solutionscom website are not a substitute to regulations concerning safety

environment and regulatory installation specifications

REMARQUES IMPORTANTES SUR LA POSEIMPORTANT NOTICES

The panels have always to be fixed on each end at less than 1 cm of the boardrsquos edge

both in horizontal and vertical installations

EPDM strip

Concrete wall

1 Batten min size 60mmOr 2 battens min size 27x40mm

6 mm expansion joint

PREPARATION OF THE STRUCTURE

CAUTION

Make sure to respect the cladding installation steps recommended by the local professional guidelines

IMPORTANT ADVICES

The supporting structure (wood or metal) has to be perfectly flat to get a perfect facade The installation has to be planned on a ventilated wood structure with a minimum batten size of

27x40mm or on omega metal profiles 30x30x30 with a 400 ou 600 mm centre to centre distance

following the buildingrsquos category and height

The supporting structure can be fitted on every kind of walls (wood metal concrete) with or without

external insulation

Always keep a minimum 2cm air gap for ventilation behind the cladding (check the

recommendations of the local regulations )

The supporting structure has to be placed perpendicular to the cladding For vertical installation

the ventilation will be enabled through the claddingrsquos ribs or thanks to a crossed structure (following

the local recommendations)

Wide board With 300 mm width

KEY INSTALLATION PRINCIPLES

Mitre cut with perfectly aligned grooving

Horizontal or vertical fitting with various layouts

Invisible fixing using steel hooks screwed into the wood or metal supporting structures

Fast fixing using screwed steel hooks

NEOLIFEreg COVER claddingcan be fitted using all the conventional facade and covering accessories

Vertical fitting with a corner profile

6mm open expansion gapat the end of the board

Horizontal fittingwith a mitre cut

or with a corner profile

Metal CopingWindow revealwith metal profile

Outside corner or window reveal with Neolife corner profile

KEY INSTALLATION PRINCIPLES

DESIGN GUIDELINES

When the sign is installed onto the claddingwith no water runoff possibility It will cause stains on the claddingwhen drying (due to the mix of dust andpollution)

Flat metall elements without watertightnessmanagement Dirty water runoff causes stains

Advice

Leave space between cladding and the signand fix it on the load-bearing wall

INSTALLATION OF SHOP SIGN

OTHERS

Sign stuck onto the wall Sign away from the wall

Advice Install the element before the cladding bymanaging the waterlightness against the wallPlan a 10 slope and a waterdrop in order toavoid a water runoff onto the cladding

infiltration Seal and fixing

Cutting for expansion

Flat Casquette

Fixing againstthe wall

Absence of water drop Water drop

DESIGN GUIDELINES

BEST PRACTICEFind all the best practices in the NEOLIFEreg installation guide

available on our website wwwneolife-solutionscom

Closed metal profile at the junction betweencladding render no water runoffpossibility risk of stains and moisture on thestructure no ventilation

Flat window sill without water drop Dust and pollution collects on the windowsill and causes stains onto the cladding afterraining

WINDOW SILL

Advice Make a window sill with a 10 slopeminimum and a water drop with 30 mm gapfrom the cladding

Flat metal window sill

30mm

Advice Use a perforated metal ending profile and raise the cladding boards 5mm above the profile

no ventilation

Visible screwWater storage

Hidden screw

Perforated closure profile ventilation and water runoff

5mm

ENDINGS JUNCTIONS

Absence of water drop Water drop

REMARQUES IMPORTANTES SUR LA POSECAUTION

THE FULL INSTALLATION MANUAL OF COVER CLADDING PANELS IS AVAILABLE AT

wwwneolife-solutionscom

NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters

disposal for any clarifications concerning the installation procedure of its products

The specifications and recommendations given in the installation guide are not a

substitute to regulations concerning safety environment and professional regulatory

dispositions

All instructions concerning the installation of our cladding are to be followed

Assembly errors are not covered by the NEOLIFEreg guarantee

An approved fitter shall be able to assess the construction conformity to the local

professional installation guidelines

MAINTENANCE

21

Depending on the boards dirt after implementation (presence of mud dust etchellip) especially in the

grooves rain stains can appear on the surface

NEOLIFE strongly recommend to clean the boards after implementation with a pressure

washer following the boardsrsquo orientation (distance of min 20cm from the board DO NOT

USE a rotary nozzle)

Recommendations

Do not forget to clean the window shelves as well avoiding so any risk of dust stains on the

cladding after the first rain (windows are frequently dusty during construction)

All metal joineries (windows parapet capping etchellip) have to have a drip-edge flashing in

order to limit the water runoff on the cladding Shop signs or any other elements installed on

the cladding have to be moved forward (space left between cladding and the element) to

avoid any stains

Caution

If any operation involving the use of asphalt or concrete occurs after facade completion

NEOLIFE recommend to protect the cladding with a plastic cover in order to avoid stains

Indeed if not protected a greasy steam can spread on the surface and in the grooves In that

case a grease-removing product will be needed to clean the boards and all the surrounding

elements

BUILDING SITE CLEANING

LONG LASTING

VERY LIMITED MAINTENANCE

The material does not require any wood preservative (oils varnishes saturators hellip)

bull The VESTAreg material is naturally equivalent to use class 4(service environment In contact with ground or fresh water amp Permanently exposed to wetting The use classes rank the risk of exposure to decay and insect attack for differing in service environments according to EN 335 ndash 2)

bull Highly hydrophobic and rot-proof no algae fungi or moss development

bull Insect-resistant does not require any treatments against termites

STAIN REMOVAL

STAINS

Tanin stains

During the first weeks after installation tannin rings may occur because of the rain especially

on claddings with a light colour They will be washed off and fade during the next rain to

lessen until they completely disappear Be careful not to mistake these stains with dust or

pollution stains which appear on all cladding types

Bleach-based cleaning products

Slight discolouration Clean with water and complete if needed with slight brushing in the

boards orientation

Graffities oil paint and ink

Use a specialised stain remover (ex laquo STG 105 BIO raquo de STG)

Bitumen grease

Use a specialised stain remover (ex laquo Scalp Aqua 03 raquo)

Oxidation stains after contact with a corroded metal

Use a specialised wood de-greyer (ex laquo Scalp Neutral DA 66 raquo)

Caution

- Analyse properly the substance to clean so to use the right stain removing product

- Always test the stain removing product on a small and discrete surface before cleaning the

entire board

- It is mandatory that you analyse on a long time scale (and after exposure to Uvs) that the

solution you choose will not react with the cladding and therefore produce unsightly effects

DAMAGES

bull Scratches cigarette marks abrasion Brush away with a brass brush (lengthways)

TECHNICAL CHARACTERISTICS

25

SYSTEM PERFORMANCES

DESIGNATIONTEST

METHODS amp STANDARDS

CLADDING OUTLIFE COVER 6 amp 14

WIND LOAD (Depression) COVER 6 (4 ribs) COVER 14 (2 ribss)

Fixings description Eurocodes EN 1991-1-4 Test results Maximum shearing

pressure Test results Maximum shearingpressure

Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction

4 900 Pa

(degradation)140 kNm2 5 200 Pa

(degradation) 148 kNm2

Maximum 400mm centre-to-centre support spacing with one fixing tab at every junction 8 300 Pa (ruine) 237 kNm2 8 300 Pa (ruine) 237 kNm2

IMPACT RESISTANCE COVER 6 (4 ribs) COVER 14 (2 ribs)

Fixings description NF P 08302 Test results Test results

Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction

No damage with the impact energies below

Soft impacts 50Kg 130J

Soft impacts 3Kg 20J

Hard impacts 1Kg 3J

No damage with the impact energies below Soft impacts 50Kg 130J

Soft impacts 3Kg 20JHard impacts 1Kg 3J

SEISMIC RESISTANCE COVER 6 amp14

COVER 6 amp 14can be installed in seismic zones and buildings according to the following details

Highest seismic behaviour following Eurocode 8 no risk of falling boards or permanent deformations after static and dynamic test

FIRE RESISTANCE COVER 6 COVER 14

Tests description EN 13823 et EN 13501-12007

Fire rating

(on A2-s1d0 wall)

Fire rating

(on A2-s1d0 wall)

SBI test carried out on 3 models forming a 1500mm high 1000mm long and 500mm wide

dihedral wedge Assembly on air board and horizontal wood batten Valable contre un

substrat A2-s1d0

B-s3d0

Equivalent UK class 0

FIGRA average 1151Ws

THR average 6MJ

SMOGRA average 371 m2s2

B-s3d0

Equivalent UK class 0

FIGRA average 1924Ws

THR average 112MJ

SMOGRA average 592m2s2

Horizontal installation Class B-s3 d0 - Vertical installation on metal framework Class B s3 d0 on wooden framework Class C s3 d0 (EN 13501-12007)

PHYSICAL AND MECHANICAL FEATURES

DESIGNATION TEST METHODES amp STANDARDS COVER 6 amp 14 OUTLIFE CLADDING

FLAMMABLE MASS COVER 6 COVER 14Tests description NF EN 13238 Flammable mass per sqm (MJ)Tests realised according to the crucible method on at least 5 product samples 334 MJ 285 MJ

APPEARANCE DURABILITY(ageing under QUV) COVER 6 amp 14

Test descriptionNF EN 927-6 (2006)

FCBA‐ LBO6-PHY‐001

Test results

Artificial ageing test under QUV allowing an assessment of durability and decorative

properties modification Total duration 10 weeks comprising

condensation UV radiation and water spray phases

Stable products according to the EN 927-2

No blistering defects are observed according to ISO 4628-2 standard Resultt 0No cracking defects are observed according to ISO 4628-4 standard Result 0No flaking defects are observed according to ISO 4628-5 standard Result 0

THERMAL EXPANSION COVER 6 amp 14

Test description

ISO 11359-2 adapted to

FCBA - LBO6PHY-001

Test results

Thermodilatometric test in climatic room going from -20deg to +60deg to determine the profils

thermal expansion coefficient in solid state

Coefficient de dilatation thermique moyen

Longitudinally δL = 380 degK-1 10-6 standard spacing 210 degK-1 10-6 For uninstalled boardsTransversally δB = 575 degK-1 10-6 standard spacing 211 degK-1 10-6 For uninstalled boards

WATER UPTAKE DETERMINATION COVER 6 amp 14

Test description FCBA‐LBO‐MECA‐014 Test results

Water uptake determination after immersion in cold water during 28 days Measure of the

mass in its initial state and after 124714 et 28 days

Boards suitable to use in class 4 (Wood use class NF EN 335-2)Boards naturally resistant against fungus and soft rotAverage water uptake after 28 days 803Water content at 28 days and imputed to the cellulosic matter 143

ELASTICITY CONSTRAINS AND MODULE IN FLEXION COVER 6 amp 14

Test description

FCBA‐LBO‐MECA‐008

NF EN 310 modifiedWPC profiles

Test results

3 point flexion under normal conditions 20degCand 65 RH

Eaverage = 904 Nmm2fm = 40 Nmm2

ENVIRONMENTAL CHARACTERISTICS

28

VESTAreg ECO-MATERIAL

VESTAreg (Vegetal Ecological Stable Timber

Advantage) is an innovative and eco-friendly compound

with exceptional properties It was developed by

NEOCOreg NEOLIFEreglsquos Research Centre specialising in

green technologies in partnership with European experts

EXCEPTIONAL WOOD FIBER CONTENTVESTAreg revolutionises eco-materials and the design of

environmental solutions for construction projects and the

landscaping of outside spaces It finally brings a response

to the architects landscapers and design officesrsquo

demands working on eco-construction and sustainable

development projects

ECO-FRIENDLYThe wood fibres contained in VESTAreg come exclusively

from sawmills offcuts the wood coming from sustainably

managed European forests The production of our material

does not require the cutting of any trees and does not use treated wood from recycled pallets Moreover

NEOLIFE does not use any toxic additives in the production process of the material

VESTAreg is 100 recyclable with a perfect traceability it only contains virgin substances (no recycled

components for which establishing a traceability is impossible)

CLEANDoes not contain solvents adhesives or phthalates and does not generate

toxic emissions

STABLE AND RESISTANTVESTAreg fibres benefit from a thermal treatment which provides hydrophobic properties to the material The

formula reinforced with mineral resin lignin and antioxidants enables a remarkable mechanical resistance as

well as an outstanding design

The mineral pigments also offer a strong resistance to UV rays making the colours more durable whatever the

exposure

SOURCE

Raw material VESTAreg

X-FIRE is highly fire-resistant Wood fibres coming from sustainably managed European forests

Board Production France

COMPOSITIONby Volume 75 wood fibres mineral oil mineral salts mineral pigments

PHYSICAL PROPERTIES

Mass sqm COVER 6 195 kgmsup2 COVER 14 165 kgmsup2

Density 1500 kgm3

Parasite resistance Equivalent to use class 4 No development of fungal rot mosses or mould Insect-resistant including termites

Surface appearance Micro-striated surface splinter free blisters or flakes off Maintenance-free

Scratches resistance Equivalent to natural wood - Brushing possible without discolouration

Thermal inertia Low thermal inertia due to the high wood fibres content

ENVIRONMENTAL PROPERTIES

Recycling 100 recyclable 75 renewable and combustible (75 biomass)

Toxic substances Contains no toxic or dangerous products (according to Reach Regulation EC19072006)

Chemical fire retardant substance None

Solvents None

Heavy metals None lead-and mercury-free stabilization

Phthalates adhesives None

Formaldehydes and VOCs Lower than or equal to natural wood

VESTAreg REINFORCED WOOD FIBER

VESTA X-FIRE

ENVIRONMENTAL PRODUCT DECLARATION

1 - Values describing the environmental impacts

Owner of the declaration NEOLIFE Editor BUREAU VERITAS CODDE Declaration reference DEP_NEOLIFE_COVER_201507

Publication 10072015 Validity 10072020

Complies with the standard ISO 14025 NF EN 15804+A1 And itrsquos national addendum X P01-064CN

Environmental Declaration of the COVER productavailable on request

ENVIRONMENTAL PRODUCT DECLARATION

2 ndash Values describing the use of primary energetic sources other resources and water

3 ndash Complementary values describing the outflows

FURTHER DETAILS

33

TECHNICAL DESCRIPTION

French accreditaion type laquo Avis Technique Expeacuterimental de Type A raquo issued by CSTB (France)

Ndeg2278 ndash Available at httpevaluationcstbfrrechercherproduits-evaluesprestations=atex

VESTA Reinforced Wood Fiber cladding containing at least 75 wood fibres

Boards with a slatted aspect featuring 6 cm or 14 cm ribs

Fire rating with natural mineral salts following EN 13501-12007

COVER 6 B-s3-d0 minimum

COVER 14 B-s3-d0 minimum

Invisible fixing with stainless steel hooks screwed into wood or metal battens

Fast and accurate fitting thanks to the interlocking board system

Outside corners catered for by using 45deg miter cuts or aluminium corner profile

Dimensional stability of maximum 2mm m over ∆80degC

rot-proof not sensitive to moss and mould

Insect-resistant termites included

Stable colors after natural patina is acquired

Contact us to get the full technical specification sheet

CONTACT

CAUTION

This technical sheet is associated with the technical installation guide of CLAD claddingboard available at wwwneolife-solutionscom

NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters

disposal for any clarifications concerning the installation procedure of its products

The specifications and recommendations given in the installation guide are not a

substitute to regulations concerning safety environment and professional regulatory

dispositions

All instructions concerning the installation of our cladding are to be followed

Assembly errors are not covered by the NEOLIFEreg guarantee

An approved fitter shall be able to assess the construction conformity to the local

professional installation guidelines

304 Route Nationale 6 ndash Celtic Parc Bacirctiment Avalon II - 69760 Limonest FranceTel +33 (0)4 78 25 63 08 ndash Fax +33 (0)4 72 29 29 47

wwwneolife-solutionscom

Page 3: COVER 6 & 14 CLADDING · 2020. 11. 3. · 60 cm centre-to-centre spacing 10 / m ... sill and causes stains onto the cladding after raining WINDOW SILL Advice : Make a window sill

DESIGN amp ENVIRONMENTAL FRIENDLY

LENGTHS AND PROFILES

325 m long and 30 cm wide board 1 sqm per board

4 ribs of 6 cm (COVER 6) 2 ribs of 14 cm (COVER 14) Shadow line width 1 cm

Shadow line depth 2 cm Possible combination of all boards

AESTHETIC The striated surface enhances the light with a change of intensity

throughout the day

Marked slatted look with regular grooving

Invisible fixing

Only 6mm expansion joint at the end of the board

NATURAL Made of VESTAreg a unique Mineral Reinforced Wood Fiber

Contains 75 wood fibres sourced from sustainably managed European

forests

Does not contain any toxic products adhesives coupling agents or heavy

metals

100 French design amp production

Environmental Product Declaration issued by VERITAS

Environmental assessment issued by the Swiss Eco-Bau laboratory

suitable for green building projects (like MINERGIE BREEAM LEED)

Cover 14 2 ribs of 14 cm

Cover 6 4 ribs of 6 cm

RESISTANCE

ACCREDITED Product approval certificates issued by the French

building office (CSTB)

STABLE AND ROT-PROOF

Exceptional dimensional stability with only 15mm

expansion per linear meter over 50degC temperature

variation or 2mmm over 80degC equal to aluminium

Rot-proof does not absorb humidity

100 insect-resistant (including termites)

Stability to UVs stabilisation on the mineral

pigmentrsquos colour

Graffiti and scratches can be easily brushed out or

cleaned off

RATINGS

FIRE REACTION COVER 6 Class B-s3 d0 (EN 13501-12007)

COVER 14

Horizontal installation Class B-s3 d0 (EN 13501-12007)

Vertical installation on metal framework Class B s3 d0 (EN 13501-12007)

on wooden framework Class C s3 d0 (EN 13501-12007)

IMPACT TEST No damages after hard and soft body impact

max impact energy 50kg-130J 3kg-20J 1kg 3J

SEISMIC TEST Highest seismic behaviour following EN 1998 amp Eurocode 8 no risk of falling

boards after static and or dynamic test

WIND LOAD Up to max 237 kN sqm shearing pressure following EN 1991 1-4

with 400mm batten spacing

THERMAL CONDUCTIVITY Low conductivity Lambda von 007 Wmk

Thermal conductivity lower than natural wood

EASY TO INSTALL

FAST amp ACCURATE IMPLEMENTATION

Can be fitted vertically or horizontally on wood or metal

structure

Wide boards of 1sqm for a fast implementation

Fast installation on ventilated batten structure with a 40 to

60cm distance

Interlocking of the boards for guaranteed regular amp parallel

grooves

Fixing by invisible steel hooks screwed into the wood

or metal structures

CORNERS AND DETAILS

Horizontal fitting 45deg mitre-cut for perfect regular corners or

aluminium corner profile with adapted RAL colour

Vertical fitting and soffits aluminium corner profile with

adapted RAL colour

NATURAL COLOURS

Due to the inherent disparities in the standardisation of screens and printing inks the shades depicted onthis sheet may appear slightly different to those of the actual samples

EarthRAL 8019

OceanRAL 7046

SandRAL 1019

HeatRAL 8017

NightRAL 9004

RAL EQUIVALENCESAbove mentioned RAL colours are matching the best to VESTAreg eco-materialrsquos tint but can not be

considered as exactly similar The given indications are informative the responsibility lies with the

customer to determine whether the RAL color fits to its project or doesnrsquot

SunRAL 1011

SIX NATURAL COLOURS TINTED THROUGHOUT WITH MINERAL PIGMENTS(Informative RAL colours for accessories)

AGEING

bull VESTAreg is a natural material composed of wood fibres and mineral pigments giving the colour

bull In the first weeks the fibre will naturally tan and then lighten up to stabilize on the mineral end

colourbull Final patina will be achieved within 10 weeks in average

BOARDS AGEING PROCESS

The final patina will be obtained within 10 weeks the fibre will naturally tan and lighten up to reach the mineral pigmentrsquos tint

NIG

HT

OC

EacuteAN

SAN

DSU

NH

EAT

Day 1 Installation After 10 weeks

EAR

TH

PROFILES amp ACCESSORIES

References Products Profiles Dimension

BF4O325O5 Cover 6 - 4 waves Ocean

BF4O325H5 Cover 6 - 4 waves Heat

BF4O325S5 Cover 6 - 4 waves Sand

BF4O325U5 Cover 6 - 4 waves Sun

BF4O325N5 Cover 6 - 4 waves Night

BF4O325E5 Cover 6 - 4 waves Earth

BF2O325O5 Cover 14 - 2 waves Ocean

BF2O325H5 Cover 14 - 2 waves Heat

BF2O325S5 Cover 14 - 2 waves Sand

BF2O325U5 Cover 14 - 2 waves Sun

BF2O325N5 Cover 14 - 2 waves Night

BF2O325E5 Cover 14 - 2 waves Earth

CORNER PROFILEReferences Products Profiles Dimension

BAPA300O1 Aluminium Corner - pack of 2 pcs Ocean

BAPA300H1 Aluminium Corner - pack of 2 pcs Heat

BAPA300S1 Aluminium Corner - pack of 2 pcs Sand

BAPA300U1 Aluminium Corner - pack of 2 pcs Sun

BAPA300N1 Aluminium Corner - pack of 2 pcs Night

BAPA300E1 Aluminium Corner - pack of 2 pcs Earth

PIERCED STARTING PROFILEReferences Products Profiles Dimension

BAPD300A1 Pack of 5 Aluminium profiles - 2 mm thickness

300 x 43 x 4 cm(L x W x H)

Colours

COVER 6 amp COVER 14Colours

Colours

Neutral

325 x 30 x 285 cm(L x W x H)

1 pcs = 0975 sqm

325 x 30 x 285 cm(L x W x H)

1 pcs = 0975 sqm

300 x 6 x 6 cm(L x W x H)

FIXINGS

Number of hooks msup2 COVER 614

60 cm centre-to-centre spacing 10 msup2

40 cm 60 cm centre-to-centre spacing 15 msup2

FIXING HOOKSReferences Products Profiles Dimension

BFCR1PI2 Fixing Hook (50 units per bag) Stainless steel 37 x 19 x 15 cm(L x W x H)

A2 STAINLESS STEEL SCREWReferences

VIS BA RAL ndeg

VIS ME RAL ndeg Bi-metal Steel screw tinted head - Box of 500 units

48 x 21mm - Inox A2 A2 stainless steel

Wood amp Alu screw tinted head - Box of 500 units

42 x 32mm - Inox A2 A2 stainless steel

Colours

Products colours

RAL color

RAL color

- Ocean 7046 - Heat 8017- Sand 1019 - Sun 1011- Night 9004 - Earth 8019

- Ocean 7046 - Heat 8017- Sand 1019 - Sun 1011- Night 9004 - Earth 8019

VIS INOX A2 - A2 STAINLESS STEEL SCREW

VIS BA NdegRAL Laqueacutee RALRAL color

16 x 11 x 7 cm(L x l x H L x W x H ) 15kg

VIS ME NdegRAL Laqueacutee RALRAL color

16 x 11 x 7 cm(L x l x H L x W x H ) 15kg

Reference Profiles Dimcm Weight in kgProduct

Wood amp Alu screw tinted head - Box of 500 units

42 x 32mm - Inox A2 A2 stainless steel

Bi-metal Steel screw tinted head - Box of 500 units

48 x 21mm - Inox A2 A2 stainless steel

- Ocean 7046 - Heat 8017- Sand 1019 - Sun 1011- Night 9004 - Earth 8019

- Ocean 7046 - Heat 8017- Sand 1019 - Sun 1011- Night 9004 - Earth 8019

4kg

4kg

INSTALLATIONKEY PRINCIPLES

10

IMPLEMENTATION ON EXTERNAL THERMAL INSULATION

Horizontal fitting

Vertical fitting

TIMBER FRAME OR MASONRY (CONCRETE BRICKhellip) WALL WITH WOOD OR METAL BATTENS

Timber frame wall

Concrete wall

Timber frame wall

Concrete wall

Insulation

Insulation

IMPORTANT

Ensure the cladding is installedon ventilated battens minimumcross-section of wooden battens27x40 mm

Centre-to-centre spacing of 400to 600 mm depending on theimplementation area requiredlayout wind force or buildingheight

This batten framework can befixed on each wall type (woodmetal concrete etc) with orwithout exterior insulation

In all cases a minimum air gap of2 cm is required behind thecladding (check local regulations)

IMPLEMENTATION ON LINER TRAYS (INDUSTRIAL BUILDING ENVELLOPE)

Horinzontal fitting

IMPORTANT

Ensure the cladding is installed onventilated battens minimum cross-section of metal battens 20 x 40 mm

Centre-to-centre spacing of 400 to600 mm depending on theimplementation area required layout wind force or building height

This batten framework can be fixedon each wall type (wood metalconcrete etc) with or without exteriorinsulation

In all cases a minimum air gap of 2cm is required behind the cladding(check local regulations)

Steelstructure

Liner trays

Vertical fitting

Insulation

Insulation

Steelstructure

Liner trays

REMARQUES IMPORTANTES SUR LA POSE

BOARD PREPARATION Length 325 cm (tolerance of +0 20 mm)

Width 320 mm visible width when installed = 300mm (tolerance of plusmn 255 mm)

Thickness 285 mm (tolerance of plusmn 115 mm)

Squaring has to be done on site

Boards have to be calibrated according to layout

START Vertical installation Start with a metal or Aluminium profile It is highly recommended to install all the

boards in the same orientation in order to obtain a uniform colour Indeed the random brushing

creates an effect on the surface that capture the lights differently according the boards orientation

Pose horizontale Boards have to be installed with the groove at the bottom and the tongue at the top

IMPORTANT NOTICES

All instructions concerning the installation of our cladding are to be followed

Assembly errors are not covered by the NEOLIFEreg guarantee

An approved fitter shall be able to assess the construction conformity to the local

professional installation guidelines

Groove at the bottom

Horizontal intallation

Tongue at the top

Verticalinstallation

Profil alu de deacutepart visseacute

Screwed aluminium starting profile

REMARQUES IMPORTANTES SUR LA POSE

ALWAYS KEEP A 6 MM EXPANSION JOINT

A minimum space of 6mm between the 325m boards

and contiguous elements (joinery wall other cladding

boards) should be left to enable the natural expansion

of the NEOLIFEreg cladding boards

Always maintain 15 mm expansion per linear meter

(or 2mm in case of high temperature variations)

IMPORTANT NOTICES

NOT FOR STRUCTURAL USE Under no circumstances should the cladding boards be used for load-bearing or structural purposes

The professional rules and recommendations governing the cladding installation must be followed

NO SEALING PROPERTIES The boards are not designed to ensure the watertightness of the external facade

They should be used with a rainscreen wherever itrsquos required which will provide the weatherproofing

element in compliance with the local Building Regulations

FIXING ADDITIONAL ITEMS TO THE FACADE The cladding is not load-bearing

Anything fixed to the facade must be attached to the supporting structure behind the cladding

6mm

CAUTIONThe specifications and recommendations given in the NEOLIFEreg installation guide available at

wwwneolife-solutionscom website are not a substitute to regulations concerning safety

environment and regulatory installation specifications

REMARQUES IMPORTANTES SUR LA POSEIMPORTANT NOTICES

The panels have always to be fixed on each end at less than 1 cm of the boardrsquos edge

both in horizontal and vertical installations

EPDM strip

Concrete wall

1 Batten min size 60mmOr 2 battens min size 27x40mm

6 mm expansion joint

PREPARATION OF THE STRUCTURE

CAUTION

Make sure to respect the cladding installation steps recommended by the local professional guidelines

IMPORTANT ADVICES

The supporting structure (wood or metal) has to be perfectly flat to get a perfect facade The installation has to be planned on a ventilated wood structure with a minimum batten size of

27x40mm or on omega metal profiles 30x30x30 with a 400 ou 600 mm centre to centre distance

following the buildingrsquos category and height

The supporting structure can be fitted on every kind of walls (wood metal concrete) with or without

external insulation

Always keep a minimum 2cm air gap for ventilation behind the cladding (check the

recommendations of the local regulations )

The supporting structure has to be placed perpendicular to the cladding For vertical installation

the ventilation will be enabled through the claddingrsquos ribs or thanks to a crossed structure (following

the local recommendations)

Wide board With 300 mm width

KEY INSTALLATION PRINCIPLES

Mitre cut with perfectly aligned grooving

Horizontal or vertical fitting with various layouts

Invisible fixing using steel hooks screwed into the wood or metal supporting structures

Fast fixing using screwed steel hooks

NEOLIFEreg COVER claddingcan be fitted using all the conventional facade and covering accessories

Vertical fitting with a corner profile

6mm open expansion gapat the end of the board

Horizontal fittingwith a mitre cut

or with a corner profile

Metal CopingWindow revealwith metal profile

Outside corner or window reveal with Neolife corner profile

KEY INSTALLATION PRINCIPLES

DESIGN GUIDELINES

When the sign is installed onto the claddingwith no water runoff possibility It will cause stains on the claddingwhen drying (due to the mix of dust andpollution)

Flat metall elements without watertightnessmanagement Dirty water runoff causes stains

Advice

Leave space between cladding and the signand fix it on the load-bearing wall

INSTALLATION OF SHOP SIGN

OTHERS

Sign stuck onto the wall Sign away from the wall

Advice Install the element before the cladding bymanaging the waterlightness against the wallPlan a 10 slope and a waterdrop in order toavoid a water runoff onto the cladding

infiltration Seal and fixing

Cutting for expansion

Flat Casquette

Fixing againstthe wall

Absence of water drop Water drop

DESIGN GUIDELINES

BEST PRACTICEFind all the best practices in the NEOLIFEreg installation guide

available on our website wwwneolife-solutionscom

Closed metal profile at the junction betweencladding render no water runoffpossibility risk of stains and moisture on thestructure no ventilation

Flat window sill without water drop Dust and pollution collects on the windowsill and causes stains onto the cladding afterraining

WINDOW SILL

Advice Make a window sill with a 10 slopeminimum and a water drop with 30 mm gapfrom the cladding

Flat metal window sill

30mm

Advice Use a perforated metal ending profile and raise the cladding boards 5mm above the profile

no ventilation

Visible screwWater storage

Hidden screw

Perforated closure profile ventilation and water runoff

5mm

ENDINGS JUNCTIONS

Absence of water drop Water drop

REMARQUES IMPORTANTES SUR LA POSECAUTION

THE FULL INSTALLATION MANUAL OF COVER CLADDING PANELS IS AVAILABLE AT

wwwneolife-solutionscom

NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters

disposal for any clarifications concerning the installation procedure of its products

The specifications and recommendations given in the installation guide are not a

substitute to regulations concerning safety environment and professional regulatory

dispositions

All instructions concerning the installation of our cladding are to be followed

Assembly errors are not covered by the NEOLIFEreg guarantee

An approved fitter shall be able to assess the construction conformity to the local

professional installation guidelines

MAINTENANCE

21

Depending on the boards dirt after implementation (presence of mud dust etchellip) especially in the

grooves rain stains can appear on the surface

NEOLIFE strongly recommend to clean the boards after implementation with a pressure

washer following the boardsrsquo orientation (distance of min 20cm from the board DO NOT

USE a rotary nozzle)

Recommendations

Do not forget to clean the window shelves as well avoiding so any risk of dust stains on the

cladding after the first rain (windows are frequently dusty during construction)

All metal joineries (windows parapet capping etchellip) have to have a drip-edge flashing in

order to limit the water runoff on the cladding Shop signs or any other elements installed on

the cladding have to be moved forward (space left between cladding and the element) to

avoid any stains

Caution

If any operation involving the use of asphalt or concrete occurs after facade completion

NEOLIFE recommend to protect the cladding with a plastic cover in order to avoid stains

Indeed if not protected a greasy steam can spread on the surface and in the grooves In that

case a grease-removing product will be needed to clean the boards and all the surrounding

elements

BUILDING SITE CLEANING

LONG LASTING

VERY LIMITED MAINTENANCE

The material does not require any wood preservative (oils varnishes saturators hellip)

bull The VESTAreg material is naturally equivalent to use class 4(service environment In contact with ground or fresh water amp Permanently exposed to wetting The use classes rank the risk of exposure to decay and insect attack for differing in service environments according to EN 335 ndash 2)

bull Highly hydrophobic and rot-proof no algae fungi or moss development

bull Insect-resistant does not require any treatments against termites

STAIN REMOVAL

STAINS

Tanin stains

During the first weeks after installation tannin rings may occur because of the rain especially

on claddings with a light colour They will be washed off and fade during the next rain to

lessen until they completely disappear Be careful not to mistake these stains with dust or

pollution stains which appear on all cladding types

Bleach-based cleaning products

Slight discolouration Clean with water and complete if needed with slight brushing in the

boards orientation

Graffities oil paint and ink

Use a specialised stain remover (ex laquo STG 105 BIO raquo de STG)

Bitumen grease

Use a specialised stain remover (ex laquo Scalp Aqua 03 raquo)

Oxidation stains after contact with a corroded metal

Use a specialised wood de-greyer (ex laquo Scalp Neutral DA 66 raquo)

Caution

- Analyse properly the substance to clean so to use the right stain removing product

- Always test the stain removing product on a small and discrete surface before cleaning the

entire board

- It is mandatory that you analyse on a long time scale (and after exposure to Uvs) that the

solution you choose will not react with the cladding and therefore produce unsightly effects

DAMAGES

bull Scratches cigarette marks abrasion Brush away with a brass brush (lengthways)

TECHNICAL CHARACTERISTICS

25

SYSTEM PERFORMANCES

DESIGNATIONTEST

METHODS amp STANDARDS

CLADDING OUTLIFE COVER 6 amp 14

WIND LOAD (Depression) COVER 6 (4 ribs) COVER 14 (2 ribss)

Fixings description Eurocodes EN 1991-1-4 Test results Maximum shearing

pressure Test results Maximum shearingpressure

Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction

4 900 Pa

(degradation)140 kNm2 5 200 Pa

(degradation) 148 kNm2

Maximum 400mm centre-to-centre support spacing with one fixing tab at every junction 8 300 Pa (ruine) 237 kNm2 8 300 Pa (ruine) 237 kNm2

IMPACT RESISTANCE COVER 6 (4 ribs) COVER 14 (2 ribs)

Fixings description NF P 08302 Test results Test results

Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction

No damage with the impact energies below

Soft impacts 50Kg 130J

Soft impacts 3Kg 20J

Hard impacts 1Kg 3J

No damage with the impact energies below Soft impacts 50Kg 130J

Soft impacts 3Kg 20JHard impacts 1Kg 3J

SEISMIC RESISTANCE COVER 6 amp14

COVER 6 amp 14can be installed in seismic zones and buildings according to the following details

Highest seismic behaviour following Eurocode 8 no risk of falling boards or permanent deformations after static and dynamic test

FIRE RESISTANCE COVER 6 COVER 14

Tests description EN 13823 et EN 13501-12007

Fire rating

(on A2-s1d0 wall)

Fire rating

(on A2-s1d0 wall)

SBI test carried out on 3 models forming a 1500mm high 1000mm long and 500mm wide

dihedral wedge Assembly on air board and horizontal wood batten Valable contre un

substrat A2-s1d0

B-s3d0

Equivalent UK class 0

FIGRA average 1151Ws

THR average 6MJ

SMOGRA average 371 m2s2

B-s3d0

Equivalent UK class 0

FIGRA average 1924Ws

THR average 112MJ

SMOGRA average 592m2s2

Horizontal installation Class B-s3 d0 - Vertical installation on metal framework Class B s3 d0 on wooden framework Class C s3 d0 (EN 13501-12007)

PHYSICAL AND MECHANICAL FEATURES

DESIGNATION TEST METHODES amp STANDARDS COVER 6 amp 14 OUTLIFE CLADDING

FLAMMABLE MASS COVER 6 COVER 14Tests description NF EN 13238 Flammable mass per sqm (MJ)Tests realised according to the crucible method on at least 5 product samples 334 MJ 285 MJ

APPEARANCE DURABILITY(ageing under QUV) COVER 6 amp 14

Test descriptionNF EN 927-6 (2006)

FCBA‐ LBO6-PHY‐001

Test results

Artificial ageing test under QUV allowing an assessment of durability and decorative

properties modification Total duration 10 weeks comprising

condensation UV radiation and water spray phases

Stable products according to the EN 927-2

No blistering defects are observed according to ISO 4628-2 standard Resultt 0No cracking defects are observed according to ISO 4628-4 standard Result 0No flaking defects are observed according to ISO 4628-5 standard Result 0

THERMAL EXPANSION COVER 6 amp 14

Test description

ISO 11359-2 adapted to

FCBA - LBO6PHY-001

Test results

Thermodilatometric test in climatic room going from -20deg to +60deg to determine the profils

thermal expansion coefficient in solid state

Coefficient de dilatation thermique moyen

Longitudinally δL = 380 degK-1 10-6 standard spacing 210 degK-1 10-6 For uninstalled boardsTransversally δB = 575 degK-1 10-6 standard spacing 211 degK-1 10-6 For uninstalled boards

WATER UPTAKE DETERMINATION COVER 6 amp 14

Test description FCBA‐LBO‐MECA‐014 Test results

Water uptake determination after immersion in cold water during 28 days Measure of the

mass in its initial state and after 124714 et 28 days

Boards suitable to use in class 4 (Wood use class NF EN 335-2)Boards naturally resistant against fungus and soft rotAverage water uptake after 28 days 803Water content at 28 days and imputed to the cellulosic matter 143

ELASTICITY CONSTRAINS AND MODULE IN FLEXION COVER 6 amp 14

Test description

FCBA‐LBO‐MECA‐008

NF EN 310 modifiedWPC profiles

Test results

3 point flexion under normal conditions 20degCand 65 RH

Eaverage = 904 Nmm2fm = 40 Nmm2

ENVIRONMENTAL CHARACTERISTICS

28

VESTAreg ECO-MATERIAL

VESTAreg (Vegetal Ecological Stable Timber

Advantage) is an innovative and eco-friendly compound

with exceptional properties It was developed by

NEOCOreg NEOLIFEreglsquos Research Centre specialising in

green technologies in partnership with European experts

EXCEPTIONAL WOOD FIBER CONTENTVESTAreg revolutionises eco-materials and the design of

environmental solutions for construction projects and the

landscaping of outside spaces It finally brings a response

to the architects landscapers and design officesrsquo

demands working on eco-construction and sustainable

development projects

ECO-FRIENDLYThe wood fibres contained in VESTAreg come exclusively

from sawmills offcuts the wood coming from sustainably

managed European forests The production of our material

does not require the cutting of any trees and does not use treated wood from recycled pallets Moreover

NEOLIFE does not use any toxic additives in the production process of the material

VESTAreg is 100 recyclable with a perfect traceability it only contains virgin substances (no recycled

components for which establishing a traceability is impossible)

CLEANDoes not contain solvents adhesives or phthalates and does not generate

toxic emissions

STABLE AND RESISTANTVESTAreg fibres benefit from a thermal treatment which provides hydrophobic properties to the material The

formula reinforced with mineral resin lignin and antioxidants enables a remarkable mechanical resistance as

well as an outstanding design

The mineral pigments also offer a strong resistance to UV rays making the colours more durable whatever the

exposure

SOURCE

Raw material VESTAreg

X-FIRE is highly fire-resistant Wood fibres coming from sustainably managed European forests

Board Production France

COMPOSITIONby Volume 75 wood fibres mineral oil mineral salts mineral pigments

PHYSICAL PROPERTIES

Mass sqm COVER 6 195 kgmsup2 COVER 14 165 kgmsup2

Density 1500 kgm3

Parasite resistance Equivalent to use class 4 No development of fungal rot mosses or mould Insect-resistant including termites

Surface appearance Micro-striated surface splinter free blisters or flakes off Maintenance-free

Scratches resistance Equivalent to natural wood - Brushing possible without discolouration

Thermal inertia Low thermal inertia due to the high wood fibres content

ENVIRONMENTAL PROPERTIES

Recycling 100 recyclable 75 renewable and combustible (75 biomass)

Toxic substances Contains no toxic or dangerous products (according to Reach Regulation EC19072006)

Chemical fire retardant substance None

Solvents None

Heavy metals None lead-and mercury-free stabilization

Phthalates adhesives None

Formaldehydes and VOCs Lower than or equal to natural wood

VESTAreg REINFORCED WOOD FIBER

VESTA X-FIRE

ENVIRONMENTAL PRODUCT DECLARATION

1 - Values describing the environmental impacts

Owner of the declaration NEOLIFE Editor BUREAU VERITAS CODDE Declaration reference DEP_NEOLIFE_COVER_201507

Publication 10072015 Validity 10072020

Complies with the standard ISO 14025 NF EN 15804+A1 And itrsquos national addendum X P01-064CN

Environmental Declaration of the COVER productavailable on request

ENVIRONMENTAL PRODUCT DECLARATION

2 ndash Values describing the use of primary energetic sources other resources and water

3 ndash Complementary values describing the outflows

FURTHER DETAILS

33

TECHNICAL DESCRIPTION

French accreditaion type laquo Avis Technique Expeacuterimental de Type A raquo issued by CSTB (France)

Ndeg2278 ndash Available at httpevaluationcstbfrrechercherproduits-evaluesprestations=atex

VESTA Reinforced Wood Fiber cladding containing at least 75 wood fibres

Boards with a slatted aspect featuring 6 cm or 14 cm ribs

Fire rating with natural mineral salts following EN 13501-12007

COVER 6 B-s3-d0 minimum

COVER 14 B-s3-d0 minimum

Invisible fixing with stainless steel hooks screwed into wood or metal battens

Fast and accurate fitting thanks to the interlocking board system

Outside corners catered for by using 45deg miter cuts or aluminium corner profile

Dimensional stability of maximum 2mm m over ∆80degC

rot-proof not sensitive to moss and mould

Insect-resistant termites included

Stable colors after natural patina is acquired

Contact us to get the full technical specification sheet

CONTACT

CAUTION

This technical sheet is associated with the technical installation guide of CLAD claddingboard available at wwwneolife-solutionscom

NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters

disposal for any clarifications concerning the installation procedure of its products

The specifications and recommendations given in the installation guide are not a

substitute to regulations concerning safety environment and professional regulatory

dispositions

All instructions concerning the installation of our cladding are to be followed

Assembly errors are not covered by the NEOLIFEreg guarantee

An approved fitter shall be able to assess the construction conformity to the local

professional installation guidelines

304 Route Nationale 6 ndash Celtic Parc Bacirctiment Avalon II - 69760 Limonest FranceTel +33 (0)4 78 25 63 08 ndash Fax +33 (0)4 72 29 29 47

wwwneolife-solutionscom

Page 4: COVER 6 & 14 CLADDING · 2020. 11. 3. · 60 cm centre-to-centre spacing 10 / m ... sill and causes stains onto the cladding after raining WINDOW SILL Advice : Make a window sill

RESISTANCE

ACCREDITED Product approval certificates issued by the French

building office (CSTB)

STABLE AND ROT-PROOF

Exceptional dimensional stability with only 15mm

expansion per linear meter over 50degC temperature

variation or 2mmm over 80degC equal to aluminium

Rot-proof does not absorb humidity

100 insect-resistant (including termites)

Stability to UVs stabilisation on the mineral

pigmentrsquos colour

Graffiti and scratches can be easily brushed out or

cleaned off

RATINGS

FIRE REACTION COVER 6 Class B-s3 d0 (EN 13501-12007)

COVER 14

Horizontal installation Class B-s3 d0 (EN 13501-12007)

Vertical installation on metal framework Class B s3 d0 (EN 13501-12007)

on wooden framework Class C s3 d0 (EN 13501-12007)

IMPACT TEST No damages after hard and soft body impact

max impact energy 50kg-130J 3kg-20J 1kg 3J

SEISMIC TEST Highest seismic behaviour following EN 1998 amp Eurocode 8 no risk of falling

boards after static and or dynamic test

WIND LOAD Up to max 237 kN sqm shearing pressure following EN 1991 1-4

with 400mm batten spacing

THERMAL CONDUCTIVITY Low conductivity Lambda von 007 Wmk

Thermal conductivity lower than natural wood

EASY TO INSTALL

FAST amp ACCURATE IMPLEMENTATION

Can be fitted vertically or horizontally on wood or metal

structure

Wide boards of 1sqm for a fast implementation

Fast installation on ventilated batten structure with a 40 to

60cm distance

Interlocking of the boards for guaranteed regular amp parallel

grooves

Fixing by invisible steel hooks screwed into the wood

or metal structures

CORNERS AND DETAILS

Horizontal fitting 45deg mitre-cut for perfect regular corners or

aluminium corner profile with adapted RAL colour

Vertical fitting and soffits aluminium corner profile with

adapted RAL colour

NATURAL COLOURS

Due to the inherent disparities in the standardisation of screens and printing inks the shades depicted onthis sheet may appear slightly different to those of the actual samples

EarthRAL 8019

OceanRAL 7046

SandRAL 1019

HeatRAL 8017

NightRAL 9004

RAL EQUIVALENCESAbove mentioned RAL colours are matching the best to VESTAreg eco-materialrsquos tint but can not be

considered as exactly similar The given indications are informative the responsibility lies with the

customer to determine whether the RAL color fits to its project or doesnrsquot

SunRAL 1011

SIX NATURAL COLOURS TINTED THROUGHOUT WITH MINERAL PIGMENTS(Informative RAL colours for accessories)

AGEING

bull VESTAreg is a natural material composed of wood fibres and mineral pigments giving the colour

bull In the first weeks the fibre will naturally tan and then lighten up to stabilize on the mineral end

colourbull Final patina will be achieved within 10 weeks in average

BOARDS AGEING PROCESS

The final patina will be obtained within 10 weeks the fibre will naturally tan and lighten up to reach the mineral pigmentrsquos tint

NIG

HT

OC

EacuteAN

SAN

DSU

NH

EAT

Day 1 Installation After 10 weeks

EAR

TH

PROFILES amp ACCESSORIES

References Products Profiles Dimension

BF4O325O5 Cover 6 - 4 waves Ocean

BF4O325H5 Cover 6 - 4 waves Heat

BF4O325S5 Cover 6 - 4 waves Sand

BF4O325U5 Cover 6 - 4 waves Sun

BF4O325N5 Cover 6 - 4 waves Night

BF4O325E5 Cover 6 - 4 waves Earth

BF2O325O5 Cover 14 - 2 waves Ocean

BF2O325H5 Cover 14 - 2 waves Heat

BF2O325S5 Cover 14 - 2 waves Sand

BF2O325U5 Cover 14 - 2 waves Sun

BF2O325N5 Cover 14 - 2 waves Night

BF2O325E5 Cover 14 - 2 waves Earth

CORNER PROFILEReferences Products Profiles Dimension

BAPA300O1 Aluminium Corner - pack of 2 pcs Ocean

BAPA300H1 Aluminium Corner - pack of 2 pcs Heat

BAPA300S1 Aluminium Corner - pack of 2 pcs Sand

BAPA300U1 Aluminium Corner - pack of 2 pcs Sun

BAPA300N1 Aluminium Corner - pack of 2 pcs Night

BAPA300E1 Aluminium Corner - pack of 2 pcs Earth

PIERCED STARTING PROFILEReferences Products Profiles Dimension

BAPD300A1 Pack of 5 Aluminium profiles - 2 mm thickness

300 x 43 x 4 cm(L x W x H)

Colours

COVER 6 amp COVER 14Colours

Colours

Neutral

325 x 30 x 285 cm(L x W x H)

1 pcs = 0975 sqm

325 x 30 x 285 cm(L x W x H)

1 pcs = 0975 sqm

300 x 6 x 6 cm(L x W x H)

FIXINGS

Number of hooks msup2 COVER 614

60 cm centre-to-centre spacing 10 msup2

40 cm 60 cm centre-to-centre spacing 15 msup2

FIXING HOOKSReferences Products Profiles Dimension

BFCR1PI2 Fixing Hook (50 units per bag) Stainless steel 37 x 19 x 15 cm(L x W x H)

A2 STAINLESS STEEL SCREWReferences

VIS BA RAL ndeg

VIS ME RAL ndeg Bi-metal Steel screw tinted head - Box of 500 units

48 x 21mm - Inox A2 A2 stainless steel

Wood amp Alu screw tinted head - Box of 500 units

42 x 32mm - Inox A2 A2 stainless steel

Colours

Products colours

RAL color

RAL color

- Ocean 7046 - Heat 8017- Sand 1019 - Sun 1011- Night 9004 - Earth 8019

- Ocean 7046 - Heat 8017- Sand 1019 - Sun 1011- Night 9004 - Earth 8019

VIS INOX A2 - A2 STAINLESS STEEL SCREW

VIS BA NdegRAL Laqueacutee RALRAL color

16 x 11 x 7 cm(L x l x H L x W x H ) 15kg

VIS ME NdegRAL Laqueacutee RALRAL color

16 x 11 x 7 cm(L x l x H L x W x H ) 15kg

Reference Profiles Dimcm Weight in kgProduct

Wood amp Alu screw tinted head - Box of 500 units

42 x 32mm - Inox A2 A2 stainless steel

Bi-metal Steel screw tinted head - Box of 500 units

48 x 21mm - Inox A2 A2 stainless steel

- Ocean 7046 - Heat 8017- Sand 1019 - Sun 1011- Night 9004 - Earth 8019

- Ocean 7046 - Heat 8017- Sand 1019 - Sun 1011- Night 9004 - Earth 8019

4kg

4kg

INSTALLATIONKEY PRINCIPLES

10

IMPLEMENTATION ON EXTERNAL THERMAL INSULATION

Horizontal fitting

Vertical fitting

TIMBER FRAME OR MASONRY (CONCRETE BRICKhellip) WALL WITH WOOD OR METAL BATTENS

Timber frame wall

Concrete wall

Timber frame wall

Concrete wall

Insulation

Insulation

IMPORTANT

Ensure the cladding is installedon ventilated battens minimumcross-section of wooden battens27x40 mm

Centre-to-centre spacing of 400to 600 mm depending on theimplementation area requiredlayout wind force or buildingheight

This batten framework can befixed on each wall type (woodmetal concrete etc) with orwithout exterior insulation

In all cases a minimum air gap of2 cm is required behind thecladding (check local regulations)

IMPLEMENTATION ON LINER TRAYS (INDUSTRIAL BUILDING ENVELLOPE)

Horinzontal fitting

IMPORTANT

Ensure the cladding is installed onventilated battens minimum cross-section of metal battens 20 x 40 mm

Centre-to-centre spacing of 400 to600 mm depending on theimplementation area required layout wind force or building height

This batten framework can be fixedon each wall type (wood metalconcrete etc) with or without exteriorinsulation

In all cases a minimum air gap of 2cm is required behind the cladding(check local regulations)

Steelstructure

Liner trays

Vertical fitting

Insulation

Insulation

Steelstructure

Liner trays

REMARQUES IMPORTANTES SUR LA POSE

BOARD PREPARATION Length 325 cm (tolerance of +0 20 mm)

Width 320 mm visible width when installed = 300mm (tolerance of plusmn 255 mm)

Thickness 285 mm (tolerance of plusmn 115 mm)

Squaring has to be done on site

Boards have to be calibrated according to layout

START Vertical installation Start with a metal or Aluminium profile It is highly recommended to install all the

boards in the same orientation in order to obtain a uniform colour Indeed the random brushing

creates an effect on the surface that capture the lights differently according the boards orientation

Pose horizontale Boards have to be installed with the groove at the bottom and the tongue at the top

IMPORTANT NOTICES

All instructions concerning the installation of our cladding are to be followed

Assembly errors are not covered by the NEOLIFEreg guarantee

An approved fitter shall be able to assess the construction conformity to the local

professional installation guidelines

Groove at the bottom

Horizontal intallation

Tongue at the top

Verticalinstallation

Profil alu de deacutepart visseacute

Screwed aluminium starting profile

REMARQUES IMPORTANTES SUR LA POSE

ALWAYS KEEP A 6 MM EXPANSION JOINT

A minimum space of 6mm between the 325m boards

and contiguous elements (joinery wall other cladding

boards) should be left to enable the natural expansion

of the NEOLIFEreg cladding boards

Always maintain 15 mm expansion per linear meter

(or 2mm in case of high temperature variations)

IMPORTANT NOTICES

NOT FOR STRUCTURAL USE Under no circumstances should the cladding boards be used for load-bearing or structural purposes

The professional rules and recommendations governing the cladding installation must be followed

NO SEALING PROPERTIES The boards are not designed to ensure the watertightness of the external facade

They should be used with a rainscreen wherever itrsquos required which will provide the weatherproofing

element in compliance with the local Building Regulations

FIXING ADDITIONAL ITEMS TO THE FACADE The cladding is not load-bearing

Anything fixed to the facade must be attached to the supporting structure behind the cladding

6mm

CAUTIONThe specifications and recommendations given in the NEOLIFEreg installation guide available at

wwwneolife-solutionscom website are not a substitute to regulations concerning safety

environment and regulatory installation specifications

REMARQUES IMPORTANTES SUR LA POSEIMPORTANT NOTICES

The panels have always to be fixed on each end at less than 1 cm of the boardrsquos edge

both in horizontal and vertical installations

EPDM strip

Concrete wall

1 Batten min size 60mmOr 2 battens min size 27x40mm

6 mm expansion joint

PREPARATION OF THE STRUCTURE

CAUTION

Make sure to respect the cladding installation steps recommended by the local professional guidelines

IMPORTANT ADVICES

The supporting structure (wood or metal) has to be perfectly flat to get a perfect facade The installation has to be planned on a ventilated wood structure with a minimum batten size of

27x40mm or on omega metal profiles 30x30x30 with a 400 ou 600 mm centre to centre distance

following the buildingrsquos category and height

The supporting structure can be fitted on every kind of walls (wood metal concrete) with or without

external insulation

Always keep a minimum 2cm air gap for ventilation behind the cladding (check the

recommendations of the local regulations )

The supporting structure has to be placed perpendicular to the cladding For vertical installation

the ventilation will be enabled through the claddingrsquos ribs or thanks to a crossed structure (following

the local recommendations)

Wide board With 300 mm width

KEY INSTALLATION PRINCIPLES

Mitre cut with perfectly aligned grooving

Horizontal or vertical fitting with various layouts

Invisible fixing using steel hooks screwed into the wood or metal supporting structures

Fast fixing using screwed steel hooks

NEOLIFEreg COVER claddingcan be fitted using all the conventional facade and covering accessories

Vertical fitting with a corner profile

6mm open expansion gapat the end of the board

Horizontal fittingwith a mitre cut

or with a corner profile

Metal CopingWindow revealwith metal profile

Outside corner or window reveal with Neolife corner profile

KEY INSTALLATION PRINCIPLES

DESIGN GUIDELINES

When the sign is installed onto the claddingwith no water runoff possibility It will cause stains on the claddingwhen drying (due to the mix of dust andpollution)

Flat metall elements without watertightnessmanagement Dirty water runoff causes stains

Advice

Leave space between cladding and the signand fix it on the load-bearing wall

INSTALLATION OF SHOP SIGN

OTHERS

Sign stuck onto the wall Sign away from the wall

Advice Install the element before the cladding bymanaging the waterlightness against the wallPlan a 10 slope and a waterdrop in order toavoid a water runoff onto the cladding

infiltration Seal and fixing

Cutting for expansion

Flat Casquette

Fixing againstthe wall

Absence of water drop Water drop

DESIGN GUIDELINES

BEST PRACTICEFind all the best practices in the NEOLIFEreg installation guide

available on our website wwwneolife-solutionscom

Closed metal profile at the junction betweencladding render no water runoffpossibility risk of stains and moisture on thestructure no ventilation

Flat window sill without water drop Dust and pollution collects on the windowsill and causes stains onto the cladding afterraining

WINDOW SILL

Advice Make a window sill with a 10 slopeminimum and a water drop with 30 mm gapfrom the cladding

Flat metal window sill

30mm

Advice Use a perforated metal ending profile and raise the cladding boards 5mm above the profile

no ventilation

Visible screwWater storage

Hidden screw

Perforated closure profile ventilation and water runoff

5mm

ENDINGS JUNCTIONS

Absence of water drop Water drop

REMARQUES IMPORTANTES SUR LA POSECAUTION

THE FULL INSTALLATION MANUAL OF COVER CLADDING PANELS IS AVAILABLE AT

wwwneolife-solutionscom

NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters

disposal for any clarifications concerning the installation procedure of its products

The specifications and recommendations given in the installation guide are not a

substitute to regulations concerning safety environment and professional regulatory

dispositions

All instructions concerning the installation of our cladding are to be followed

Assembly errors are not covered by the NEOLIFEreg guarantee

An approved fitter shall be able to assess the construction conformity to the local

professional installation guidelines

MAINTENANCE

21

Depending on the boards dirt after implementation (presence of mud dust etchellip) especially in the

grooves rain stains can appear on the surface

NEOLIFE strongly recommend to clean the boards after implementation with a pressure

washer following the boardsrsquo orientation (distance of min 20cm from the board DO NOT

USE a rotary nozzle)

Recommendations

Do not forget to clean the window shelves as well avoiding so any risk of dust stains on the

cladding after the first rain (windows are frequently dusty during construction)

All metal joineries (windows parapet capping etchellip) have to have a drip-edge flashing in

order to limit the water runoff on the cladding Shop signs or any other elements installed on

the cladding have to be moved forward (space left between cladding and the element) to

avoid any stains

Caution

If any operation involving the use of asphalt or concrete occurs after facade completion

NEOLIFE recommend to protect the cladding with a plastic cover in order to avoid stains

Indeed if not protected a greasy steam can spread on the surface and in the grooves In that

case a grease-removing product will be needed to clean the boards and all the surrounding

elements

BUILDING SITE CLEANING

LONG LASTING

VERY LIMITED MAINTENANCE

The material does not require any wood preservative (oils varnishes saturators hellip)

bull The VESTAreg material is naturally equivalent to use class 4(service environment In contact with ground or fresh water amp Permanently exposed to wetting The use classes rank the risk of exposure to decay and insect attack for differing in service environments according to EN 335 ndash 2)

bull Highly hydrophobic and rot-proof no algae fungi or moss development

bull Insect-resistant does not require any treatments against termites

STAIN REMOVAL

STAINS

Tanin stains

During the first weeks after installation tannin rings may occur because of the rain especially

on claddings with a light colour They will be washed off and fade during the next rain to

lessen until they completely disappear Be careful not to mistake these stains with dust or

pollution stains which appear on all cladding types

Bleach-based cleaning products

Slight discolouration Clean with water and complete if needed with slight brushing in the

boards orientation

Graffities oil paint and ink

Use a specialised stain remover (ex laquo STG 105 BIO raquo de STG)

Bitumen grease

Use a specialised stain remover (ex laquo Scalp Aqua 03 raquo)

Oxidation stains after contact with a corroded metal

Use a specialised wood de-greyer (ex laquo Scalp Neutral DA 66 raquo)

Caution

- Analyse properly the substance to clean so to use the right stain removing product

- Always test the stain removing product on a small and discrete surface before cleaning the

entire board

- It is mandatory that you analyse on a long time scale (and after exposure to Uvs) that the

solution you choose will not react with the cladding and therefore produce unsightly effects

DAMAGES

bull Scratches cigarette marks abrasion Brush away with a brass brush (lengthways)

TECHNICAL CHARACTERISTICS

25

SYSTEM PERFORMANCES

DESIGNATIONTEST

METHODS amp STANDARDS

CLADDING OUTLIFE COVER 6 amp 14

WIND LOAD (Depression) COVER 6 (4 ribs) COVER 14 (2 ribss)

Fixings description Eurocodes EN 1991-1-4 Test results Maximum shearing

pressure Test results Maximum shearingpressure

Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction

4 900 Pa

(degradation)140 kNm2 5 200 Pa

(degradation) 148 kNm2

Maximum 400mm centre-to-centre support spacing with one fixing tab at every junction 8 300 Pa (ruine) 237 kNm2 8 300 Pa (ruine) 237 kNm2

IMPACT RESISTANCE COVER 6 (4 ribs) COVER 14 (2 ribs)

Fixings description NF P 08302 Test results Test results

Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction

No damage with the impact energies below

Soft impacts 50Kg 130J

Soft impacts 3Kg 20J

Hard impacts 1Kg 3J

No damage with the impact energies below Soft impacts 50Kg 130J

Soft impacts 3Kg 20JHard impacts 1Kg 3J

SEISMIC RESISTANCE COVER 6 amp14

COVER 6 amp 14can be installed in seismic zones and buildings according to the following details

Highest seismic behaviour following Eurocode 8 no risk of falling boards or permanent deformations after static and dynamic test

FIRE RESISTANCE COVER 6 COVER 14

Tests description EN 13823 et EN 13501-12007

Fire rating

(on A2-s1d0 wall)

Fire rating

(on A2-s1d0 wall)

SBI test carried out on 3 models forming a 1500mm high 1000mm long and 500mm wide

dihedral wedge Assembly on air board and horizontal wood batten Valable contre un

substrat A2-s1d0

B-s3d0

Equivalent UK class 0

FIGRA average 1151Ws

THR average 6MJ

SMOGRA average 371 m2s2

B-s3d0

Equivalent UK class 0

FIGRA average 1924Ws

THR average 112MJ

SMOGRA average 592m2s2

Horizontal installation Class B-s3 d0 - Vertical installation on metal framework Class B s3 d0 on wooden framework Class C s3 d0 (EN 13501-12007)

PHYSICAL AND MECHANICAL FEATURES

DESIGNATION TEST METHODES amp STANDARDS COVER 6 amp 14 OUTLIFE CLADDING

FLAMMABLE MASS COVER 6 COVER 14Tests description NF EN 13238 Flammable mass per sqm (MJ)Tests realised according to the crucible method on at least 5 product samples 334 MJ 285 MJ

APPEARANCE DURABILITY(ageing under QUV) COVER 6 amp 14

Test descriptionNF EN 927-6 (2006)

FCBA‐ LBO6-PHY‐001

Test results

Artificial ageing test under QUV allowing an assessment of durability and decorative

properties modification Total duration 10 weeks comprising

condensation UV radiation and water spray phases

Stable products according to the EN 927-2

No blistering defects are observed according to ISO 4628-2 standard Resultt 0No cracking defects are observed according to ISO 4628-4 standard Result 0No flaking defects are observed according to ISO 4628-5 standard Result 0

THERMAL EXPANSION COVER 6 amp 14

Test description

ISO 11359-2 adapted to

FCBA - LBO6PHY-001

Test results

Thermodilatometric test in climatic room going from -20deg to +60deg to determine the profils

thermal expansion coefficient in solid state

Coefficient de dilatation thermique moyen

Longitudinally δL = 380 degK-1 10-6 standard spacing 210 degK-1 10-6 For uninstalled boardsTransversally δB = 575 degK-1 10-6 standard spacing 211 degK-1 10-6 For uninstalled boards

WATER UPTAKE DETERMINATION COVER 6 amp 14

Test description FCBA‐LBO‐MECA‐014 Test results

Water uptake determination after immersion in cold water during 28 days Measure of the

mass in its initial state and after 124714 et 28 days

Boards suitable to use in class 4 (Wood use class NF EN 335-2)Boards naturally resistant against fungus and soft rotAverage water uptake after 28 days 803Water content at 28 days and imputed to the cellulosic matter 143

ELASTICITY CONSTRAINS AND MODULE IN FLEXION COVER 6 amp 14

Test description

FCBA‐LBO‐MECA‐008

NF EN 310 modifiedWPC profiles

Test results

3 point flexion under normal conditions 20degCand 65 RH

Eaverage = 904 Nmm2fm = 40 Nmm2

ENVIRONMENTAL CHARACTERISTICS

28

VESTAreg ECO-MATERIAL

VESTAreg (Vegetal Ecological Stable Timber

Advantage) is an innovative and eco-friendly compound

with exceptional properties It was developed by

NEOCOreg NEOLIFEreglsquos Research Centre specialising in

green technologies in partnership with European experts

EXCEPTIONAL WOOD FIBER CONTENTVESTAreg revolutionises eco-materials and the design of

environmental solutions for construction projects and the

landscaping of outside spaces It finally brings a response

to the architects landscapers and design officesrsquo

demands working on eco-construction and sustainable

development projects

ECO-FRIENDLYThe wood fibres contained in VESTAreg come exclusively

from sawmills offcuts the wood coming from sustainably

managed European forests The production of our material

does not require the cutting of any trees and does not use treated wood from recycled pallets Moreover

NEOLIFE does not use any toxic additives in the production process of the material

VESTAreg is 100 recyclable with a perfect traceability it only contains virgin substances (no recycled

components for which establishing a traceability is impossible)

CLEANDoes not contain solvents adhesives or phthalates and does not generate

toxic emissions

STABLE AND RESISTANTVESTAreg fibres benefit from a thermal treatment which provides hydrophobic properties to the material The

formula reinforced with mineral resin lignin and antioxidants enables a remarkable mechanical resistance as

well as an outstanding design

The mineral pigments also offer a strong resistance to UV rays making the colours more durable whatever the

exposure

SOURCE

Raw material VESTAreg

X-FIRE is highly fire-resistant Wood fibres coming from sustainably managed European forests

Board Production France

COMPOSITIONby Volume 75 wood fibres mineral oil mineral salts mineral pigments

PHYSICAL PROPERTIES

Mass sqm COVER 6 195 kgmsup2 COVER 14 165 kgmsup2

Density 1500 kgm3

Parasite resistance Equivalent to use class 4 No development of fungal rot mosses or mould Insect-resistant including termites

Surface appearance Micro-striated surface splinter free blisters or flakes off Maintenance-free

Scratches resistance Equivalent to natural wood - Brushing possible without discolouration

Thermal inertia Low thermal inertia due to the high wood fibres content

ENVIRONMENTAL PROPERTIES

Recycling 100 recyclable 75 renewable and combustible (75 biomass)

Toxic substances Contains no toxic or dangerous products (according to Reach Regulation EC19072006)

Chemical fire retardant substance None

Solvents None

Heavy metals None lead-and mercury-free stabilization

Phthalates adhesives None

Formaldehydes and VOCs Lower than or equal to natural wood

VESTAreg REINFORCED WOOD FIBER

VESTA X-FIRE

ENVIRONMENTAL PRODUCT DECLARATION

1 - Values describing the environmental impacts

Owner of the declaration NEOLIFE Editor BUREAU VERITAS CODDE Declaration reference DEP_NEOLIFE_COVER_201507

Publication 10072015 Validity 10072020

Complies with the standard ISO 14025 NF EN 15804+A1 And itrsquos national addendum X P01-064CN

Environmental Declaration of the COVER productavailable on request

ENVIRONMENTAL PRODUCT DECLARATION

2 ndash Values describing the use of primary energetic sources other resources and water

3 ndash Complementary values describing the outflows

FURTHER DETAILS

33

TECHNICAL DESCRIPTION

French accreditaion type laquo Avis Technique Expeacuterimental de Type A raquo issued by CSTB (France)

Ndeg2278 ndash Available at httpevaluationcstbfrrechercherproduits-evaluesprestations=atex

VESTA Reinforced Wood Fiber cladding containing at least 75 wood fibres

Boards with a slatted aspect featuring 6 cm or 14 cm ribs

Fire rating with natural mineral salts following EN 13501-12007

COVER 6 B-s3-d0 minimum

COVER 14 B-s3-d0 minimum

Invisible fixing with stainless steel hooks screwed into wood or metal battens

Fast and accurate fitting thanks to the interlocking board system

Outside corners catered for by using 45deg miter cuts or aluminium corner profile

Dimensional stability of maximum 2mm m over ∆80degC

rot-proof not sensitive to moss and mould

Insect-resistant termites included

Stable colors after natural patina is acquired

Contact us to get the full technical specification sheet

CONTACT

CAUTION

This technical sheet is associated with the technical installation guide of CLAD claddingboard available at wwwneolife-solutionscom

NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters

disposal for any clarifications concerning the installation procedure of its products

The specifications and recommendations given in the installation guide are not a

substitute to regulations concerning safety environment and professional regulatory

dispositions

All instructions concerning the installation of our cladding are to be followed

Assembly errors are not covered by the NEOLIFEreg guarantee

An approved fitter shall be able to assess the construction conformity to the local

professional installation guidelines

304 Route Nationale 6 ndash Celtic Parc Bacirctiment Avalon II - 69760 Limonest FranceTel +33 (0)4 78 25 63 08 ndash Fax +33 (0)4 72 29 29 47

wwwneolife-solutionscom

Page 5: COVER 6 & 14 CLADDING · 2020. 11. 3. · 60 cm centre-to-centre spacing 10 / m ... sill and causes stains onto the cladding after raining WINDOW SILL Advice : Make a window sill

EASY TO INSTALL

FAST amp ACCURATE IMPLEMENTATION

Can be fitted vertically or horizontally on wood or metal

structure

Wide boards of 1sqm for a fast implementation

Fast installation on ventilated batten structure with a 40 to

60cm distance

Interlocking of the boards for guaranteed regular amp parallel

grooves

Fixing by invisible steel hooks screwed into the wood

or metal structures

CORNERS AND DETAILS

Horizontal fitting 45deg mitre-cut for perfect regular corners or

aluminium corner profile with adapted RAL colour

Vertical fitting and soffits aluminium corner profile with

adapted RAL colour

NATURAL COLOURS

Due to the inherent disparities in the standardisation of screens and printing inks the shades depicted onthis sheet may appear slightly different to those of the actual samples

EarthRAL 8019

OceanRAL 7046

SandRAL 1019

HeatRAL 8017

NightRAL 9004

RAL EQUIVALENCESAbove mentioned RAL colours are matching the best to VESTAreg eco-materialrsquos tint but can not be

considered as exactly similar The given indications are informative the responsibility lies with the

customer to determine whether the RAL color fits to its project or doesnrsquot

SunRAL 1011

SIX NATURAL COLOURS TINTED THROUGHOUT WITH MINERAL PIGMENTS(Informative RAL colours for accessories)

AGEING

bull VESTAreg is a natural material composed of wood fibres and mineral pigments giving the colour

bull In the first weeks the fibre will naturally tan and then lighten up to stabilize on the mineral end

colourbull Final patina will be achieved within 10 weeks in average

BOARDS AGEING PROCESS

The final patina will be obtained within 10 weeks the fibre will naturally tan and lighten up to reach the mineral pigmentrsquos tint

NIG

HT

OC

EacuteAN

SAN

DSU

NH

EAT

Day 1 Installation After 10 weeks

EAR

TH

PROFILES amp ACCESSORIES

References Products Profiles Dimension

BF4O325O5 Cover 6 - 4 waves Ocean

BF4O325H5 Cover 6 - 4 waves Heat

BF4O325S5 Cover 6 - 4 waves Sand

BF4O325U5 Cover 6 - 4 waves Sun

BF4O325N5 Cover 6 - 4 waves Night

BF4O325E5 Cover 6 - 4 waves Earth

BF2O325O5 Cover 14 - 2 waves Ocean

BF2O325H5 Cover 14 - 2 waves Heat

BF2O325S5 Cover 14 - 2 waves Sand

BF2O325U5 Cover 14 - 2 waves Sun

BF2O325N5 Cover 14 - 2 waves Night

BF2O325E5 Cover 14 - 2 waves Earth

CORNER PROFILEReferences Products Profiles Dimension

BAPA300O1 Aluminium Corner - pack of 2 pcs Ocean

BAPA300H1 Aluminium Corner - pack of 2 pcs Heat

BAPA300S1 Aluminium Corner - pack of 2 pcs Sand

BAPA300U1 Aluminium Corner - pack of 2 pcs Sun

BAPA300N1 Aluminium Corner - pack of 2 pcs Night

BAPA300E1 Aluminium Corner - pack of 2 pcs Earth

PIERCED STARTING PROFILEReferences Products Profiles Dimension

BAPD300A1 Pack of 5 Aluminium profiles - 2 mm thickness

300 x 43 x 4 cm(L x W x H)

Colours

COVER 6 amp COVER 14Colours

Colours

Neutral

325 x 30 x 285 cm(L x W x H)

1 pcs = 0975 sqm

325 x 30 x 285 cm(L x W x H)

1 pcs = 0975 sqm

300 x 6 x 6 cm(L x W x H)

FIXINGS

Number of hooks msup2 COVER 614

60 cm centre-to-centre spacing 10 msup2

40 cm 60 cm centre-to-centre spacing 15 msup2

FIXING HOOKSReferences Products Profiles Dimension

BFCR1PI2 Fixing Hook (50 units per bag) Stainless steel 37 x 19 x 15 cm(L x W x H)

A2 STAINLESS STEEL SCREWReferences

VIS BA RAL ndeg

VIS ME RAL ndeg Bi-metal Steel screw tinted head - Box of 500 units

48 x 21mm - Inox A2 A2 stainless steel

Wood amp Alu screw tinted head - Box of 500 units

42 x 32mm - Inox A2 A2 stainless steel

Colours

Products colours

RAL color

RAL color

- Ocean 7046 - Heat 8017- Sand 1019 - Sun 1011- Night 9004 - Earth 8019

- Ocean 7046 - Heat 8017- Sand 1019 - Sun 1011- Night 9004 - Earth 8019

VIS INOX A2 - A2 STAINLESS STEEL SCREW

VIS BA NdegRAL Laqueacutee RALRAL color

16 x 11 x 7 cm(L x l x H L x W x H ) 15kg

VIS ME NdegRAL Laqueacutee RALRAL color

16 x 11 x 7 cm(L x l x H L x W x H ) 15kg

Reference Profiles Dimcm Weight in kgProduct

Wood amp Alu screw tinted head - Box of 500 units

42 x 32mm - Inox A2 A2 stainless steel

Bi-metal Steel screw tinted head - Box of 500 units

48 x 21mm - Inox A2 A2 stainless steel

- Ocean 7046 - Heat 8017- Sand 1019 - Sun 1011- Night 9004 - Earth 8019

- Ocean 7046 - Heat 8017- Sand 1019 - Sun 1011- Night 9004 - Earth 8019

4kg

4kg

INSTALLATIONKEY PRINCIPLES

10

IMPLEMENTATION ON EXTERNAL THERMAL INSULATION

Horizontal fitting

Vertical fitting

TIMBER FRAME OR MASONRY (CONCRETE BRICKhellip) WALL WITH WOOD OR METAL BATTENS

Timber frame wall

Concrete wall

Timber frame wall

Concrete wall

Insulation

Insulation

IMPORTANT

Ensure the cladding is installedon ventilated battens minimumcross-section of wooden battens27x40 mm

Centre-to-centre spacing of 400to 600 mm depending on theimplementation area requiredlayout wind force or buildingheight

This batten framework can befixed on each wall type (woodmetal concrete etc) with orwithout exterior insulation

In all cases a minimum air gap of2 cm is required behind thecladding (check local regulations)

IMPLEMENTATION ON LINER TRAYS (INDUSTRIAL BUILDING ENVELLOPE)

Horinzontal fitting

IMPORTANT

Ensure the cladding is installed onventilated battens minimum cross-section of metal battens 20 x 40 mm

Centre-to-centre spacing of 400 to600 mm depending on theimplementation area required layout wind force or building height

This batten framework can be fixedon each wall type (wood metalconcrete etc) with or without exteriorinsulation

In all cases a minimum air gap of 2cm is required behind the cladding(check local regulations)

Steelstructure

Liner trays

Vertical fitting

Insulation

Insulation

Steelstructure

Liner trays

REMARQUES IMPORTANTES SUR LA POSE

BOARD PREPARATION Length 325 cm (tolerance of +0 20 mm)

Width 320 mm visible width when installed = 300mm (tolerance of plusmn 255 mm)

Thickness 285 mm (tolerance of plusmn 115 mm)

Squaring has to be done on site

Boards have to be calibrated according to layout

START Vertical installation Start with a metal or Aluminium profile It is highly recommended to install all the

boards in the same orientation in order to obtain a uniform colour Indeed the random brushing

creates an effect on the surface that capture the lights differently according the boards orientation

Pose horizontale Boards have to be installed with the groove at the bottom and the tongue at the top

IMPORTANT NOTICES

All instructions concerning the installation of our cladding are to be followed

Assembly errors are not covered by the NEOLIFEreg guarantee

An approved fitter shall be able to assess the construction conformity to the local

professional installation guidelines

Groove at the bottom

Horizontal intallation

Tongue at the top

Verticalinstallation

Profil alu de deacutepart visseacute

Screwed aluminium starting profile

REMARQUES IMPORTANTES SUR LA POSE

ALWAYS KEEP A 6 MM EXPANSION JOINT

A minimum space of 6mm between the 325m boards

and contiguous elements (joinery wall other cladding

boards) should be left to enable the natural expansion

of the NEOLIFEreg cladding boards

Always maintain 15 mm expansion per linear meter

(or 2mm in case of high temperature variations)

IMPORTANT NOTICES

NOT FOR STRUCTURAL USE Under no circumstances should the cladding boards be used for load-bearing or structural purposes

The professional rules and recommendations governing the cladding installation must be followed

NO SEALING PROPERTIES The boards are not designed to ensure the watertightness of the external facade

They should be used with a rainscreen wherever itrsquos required which will provide the weatherproofing

element in compliance with the local Building Regulations

FIXING ADDITIONAL ITEMS TO THE FACADE The cladding is not load-bearing

Anything fixed to the facade must be attached to the supporting structure behind the cladding

6mm

CAUTIONThe specifications and recommendations given in the NEOLIFEreg installation guide available at

wwwneolife-solutionscom website are not a substitute to regulations concerning safety

environment and regulatory installation specifications

REMARQUES IMPORTANTES SUR LA POSEIMPORTANT NOTICES

The panels have always to be fixed on each end at less than 1 cm of the boardrsquos edge

both in horizontal and vertical installations

EPDM strip

Concrete wall

1 Batten min size 60mmOr 2 battens min size 27x40mm

6 mm expansion joint

PREPARATION OF THE STRUCTURE

CAUTION

Make sure to respect the cladding installation steps recommended by the local professional guidelines

IMPORTANT ADVICES

The supporting structure (wood or metal) has to be perfectly flat to get a perfect facade The installation has to be planned on a ventilated wood structure with a minimum batten size of

27x40mm or on omega metal profiles 30x30x30 with a 400 ou 600 mm centre to centre distance

following the buildingrsquos category and height

The supporting structure can be fitted on every kind of walls (wood metal concrete) with or without

external insulation

Always keep a minimum 2cm air gap for ventilation behind the cladding (check the

recommendations of the local regulations )

The supporting structure has to be placed perpendicular to the cladding For vertical installation

the ventilation will be enabled through the claddingrsquos ribs or thanks to a crossed structure (following

the local recommendations)

Wide board With 300 mm width

KEY INSTALLATION PRINCIPLES

Mitre cut with perfectly aligned grooving

Horizontal or vertical fitting with various layouts

Invisible fixing using steel hooks screwed into the wood or metal supporting structures

Fast fixing using screwed steel hooks

NEOLIFEreg COVER claddingcan be fitted using all the conventional facade and covering accessories

Vertical fitting with a corner profile

6mm open expansion gapat the end of the board

Horizontal fittingwith a mitre cut

or with a corner profile

Metal CopingWindow revealwith metal profile

Outside corner or window reveal with Neolife corner profile

KEY INSTALLATION PRINCIPLES

DESIGN GUIDELINES

When the sign is installed onto the claddingwith no water runoff possibility It will cause stains on the claddingwhen drying (due to the mix of dust andpollution)

Flat metall elements without watertightnessmanagement Dirty water runoff causes stains

Advice

Leave space between cladding and the signand fix it on the load-bearing wall

INSTALLATION OF SHOP SIGN

OTHERS

Sign stuck onto the wall Sign away from the wall

Advice Install the element before the cladding bymanaging the waterlightness against the wallPlan a 10 slope and a waterdrop in order toavoid a water runoff onto the cladding

infiltration Seal and fixing

Cutting for expansion

Flat Casquette

Fixing againstthe wall

Absence of water drop Water drop

DESIGN GUIDELINES

BEST PRACTICEFind all the best practices in the NEOLIFEreg installation guide

available on our website wwwneolife-solutionscom

Closed metal profile at the junction betweencladding render no water runoffpossibility risk of stains and moisture on thestructure no ventilation

Flat window sill without water drop Dust and pollution collects on the windowsill and causes stains onto the cladding afterraining

WINDOW SILL

Advice Make a window sill with a 10 slopeminimum and a water drop with 30 mm gapfrom the cladding

Flat metal window sill

30mm

Advice Use a perforated metal ending profile and raise the cladding boards 5mm above the profile

no ventilation

Visible screwWater storage

Hidden screw

Perforated closure profile ventilation and water runoff

5mm

ENDINGS JUNCTIONS

Absence of water drop Water drop

REMARQUES IMPORTANTES SUR LA POSECAUTION

THE FULL INSTALLATION MANUAL OF COVER CLADDING PANELS IS AVAILABLE AT

wwwneolife-solutionscom

NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters

disposal for any clarifications concerning the installation procedure of its products

The specifications and recommendations given in the installation guide are not a

substitute to regulations concerning safety environment and professional regulatory

dispositions

All instructions concerning the installation of our cladding are to be followed

Assembly errors are not covered by the NEOLIFEreg guarantee

An approved fitter shall be able to assess the construction conformity to the local

professional installation guidelines

MAINTENANCE

21

Depending on the boards dirt after implementation (presence of mud dust etchellip) especially in the

grooves rain stains can appear on the surface

NEOLIFE strongly recommend to clean the boards after implementation with a pressure

washer following the boardsrsquo orientation (distance of min 20cm from the board DO NOT

USE a rotary nozzle)

Recommendations

Do not forget to clean the window shelves as well avoiding so any risk of dust stains on the

cladding after the first rain (windows are frequently dusty during construction)

All metal joineries (windows parapet capping etchellip) have to have a drip-edge flashing in

order to limit the water runoff on the cladding Shop signs or any other elements installed on

the cladding have to be moved forward (space left between cladding and the element) to

avoid any stains

Caution

If any operation involving the use of asphalt or concrete occurs after facade completion

NEOLIFE recommend to protect the cladding with a plastic cover in order to avoid stains

Indeed if not protected a greasy steam can spread on the surface and in the grooves In that

case a grease-removing product will be needed to clean the boards and all the surrounding

elements

BUILDING SITE CLEANING

LONG LASTING

VERY LIMITED MAINTENANCE

The material does not require any wood preservative (oils varnishes saturators hellip)

bull The VESTAreg material is naturally equivalent to use class 4(service environment In contact with ground or fresh water amp Permanently exposed to wetting The use classes rank the risk of exposure to decay and insect attack for differing in service environments according to EN 335 ndash 2)

bull Highly hydrophobic and rot-proof no algae fungi or moss development

bull Insect-resistant does not require any treatments against termites

STAIN REMOVAL

STAINS

Tanin stains

During the first weeks after installation tannin rings may occur because of the rain especially

on claddings with a light colour They will be washed off and fade during the next rain to

lessen until they completely disappear Be careful not to mistake these stains with dust or

pollution stains which appear on all cladding types

Bleach-based cleaning products

Slight discolouration Clean with water and complete if needed with slight brushing in the

boards orientation

Graffities oil paint and ink

Use a specialised stain remover (ex laquo STG 105 BIO raquo de STG)

Bitumen grease

Use a specialised stain remover (ex laquo Scalp Aqua 03 raquo)

Oxidation stains after contact with a corroded metal

Use a specialised wood de-greyer (ex laquo Scalp Neutral DA 66 raquo)

Caution

- Analyse properly the substance to clean so to use the right stain removing product

- Always test the stain removing product on a small and discrete surface before cleaning the

entire board

- It is mandatory that you analyse on a long time scale (and after exposure to Uvs) that the

solution you choose will not react with the cladding and therefore produce unsightly effects

DAMAGES

bull Scratches cigarette marks abrasion Brush away with a brass brush (lengthways)

TECHNICAL CHARACTERISTICS

25

SYSTEM PERFORMANCES

DESIGNATIONTEST

METHODS amp STANDARDS

CLADDING OUTLIFE COVER 6 amp 14

WIND LOAD (Depression) COVER 6 (4 ribs) COVER 14 (2 ribss)

Fixings description Eurocodes EN 1991-1-4 Test results Maximum shearing

pressure Test results Maximum shearingpressure

Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction

4 900 Pa

(degradation)140 kNm2 5 200 Pa

(degradation) 148 kNm2

Maximum 400mm centre-to-centre support spacing with one fixing tab at every junction 8 300 Pa (ruine) 237 kNm2 8 300 Pa (ruine) 237 kNm2

IMPACT RESISTANCE COVER 6 (4 ribs) COVER 14 (2 ribs)

Fixings description NF P 08302 Test results Test results

Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction

No damage with the impact energies below

Soft impacts 50Kg 130J

Soft impacts 3Kg 20J

Hard impacts 1Kg 3J

No damage with the impact energies below Soft impacts 50Kg 130J

Soft impacts 3Kg 20JHard impacts 1Kg 3J

SEISMIC RESISTANCE COVER 6 amp14

COVER 6 amp 14can be installed in seismic zones and buildings according to the following details

Highest seismic behaviour following Eurocode 8 no risk of falling boards or permanent deformations after static and dynamic test

FIRE RESISTANCE COVER 6 COVER 14

Tests description EN 13823 et EN 13501-12007

Fire rating

(on A2-s1d0 wall)

Fire rating

(on A2-s1d0 wall)

SBI test carried out on 3 models forming a 1500mm high 1000mm long and 500mm wide

dihedral wedge Assembly on air board and horizontal wood batten Valable contre un

substrat A2-s1d0

B-s3d0

Equivalent UK class 0

FIGRA average 1151Ws

THR average 6MJ

SMOGRA average 371 m2s2

B-s3d0

Equivalent UK class 0

FIGRA average 1924Ws

THR average 112MJ

SMOGRA average 592m2s2

Horizontal installation Class B-s3 d0 - Vertical installation on metal framework Class B s3 d0 on wooden framework Class C s3 d0 (EN 13501-12007)

PHYSICAL AND MECHANICAL FEATURES

DESIGNATION TEST METHODES amp STANDARDS COVER 6 amp 14 OUTLIFE CLADDING

FLAMMABLE MASS COVER 6 COVER 14Tests description NF EN 13238 Flammable mass per sqm (MJ)Tests realised according to the crucible method on at least 5 product samples 334 MJ 285 MJ

APPEARANCE DURABILITY(ageing under QUV) COVER 6 amp 14

Test descriptionNF EN 927-6 (2006)

FCBA‐ LBO6-PHY‐001

Test results

Artificial ageing test under QUV allowing an assessment of durability and decorative

properties modification Total duration 10 weeks comprising

condensation UV radiation and water spray phases

Stable products according to the EN 927-2

No blistering defects are observed according to ISO 4628-2 standard Resultt 0No cracking defects are observed according to ISO 4628-4 standard Result 0No flaking defects are observed according to ISO 4628-5 standard Result 0

THERMAL EXPANSION COVER 6 amp 14

Test description

ISO 11359-2 adapted to

FCBA - LBO6PHY-001

Test results

Thermodilatometric test in climatic room going from -20deg to +60deg to determine the profils

thermal expansion coefficient in solid state

Coefficient de dilatation thermique moyen

Longitudinally δL = 380 degK-1 10-6 standard spacing 210 degK-1 10-6 For uninstalled boardsTransversally δB = 575 degK-1 10-6 standard spacing 211 degK-1 10-6 For uninstalled boards

WATER UPTAKE DETERMINATION COVER 6 amp 14

Test description FCBA‐LBO‐MECA‐014 Test results

Water uptake determination after immersion in cold water during 28 days Measure of the

mass in its initial state and after 124714 et 28 days

Boards suitable to use in class 4 (Wood use class NF EN 335-2)Boards naturally resistant against fungus and soft rotAverage water uptake after 28 days 803Water content at 28 days and imputed to the cellulosic matter 143

ELASTICITY CONSTRAINS AND MODULE IN FLEXION COVER 6 amp 14

Test description

FCBA‐LBO‐MECA‐008

NF EN 310 modifiedWPC profiles

Test results

3 point flexion under normal conditions 20degCand 65 RH

Eaverage = 904 Nmm2fm = 40 Nmm2

ENVIRONMENTAL CHARACTERISTICS

28

VESTAreg ECO-MATERIAL

VESTAreg (Vegetal Ecological Stable Timber

Advantage) is an innovative and eco-friendly compound

with exceptional properties It was developed by

NEOCOreg NEOLIFEreglsquos Research Centre specialising in

green technologies in partnership with European experts

EXCEPTIONAL WOOD FIBER CONTENTVESTAreg revolutionises eco-materials and the design of

environmental solutions for construction projects and the

landscaping of outside spaces It finally brings a response

to the architects landscapers and design officesrsquo

demands working on eco-construction and sustainable

development projects

ECO-FRIENDLYThe wood fibres contained in VESTAreg come exclusively

from sawmills offcuts the wood coming from sustainably

managed European forests The production of our material

does not require the cutting of any trees and does not use treated wood from recycled pallets Moreover

NEOLIFE does not use any toxic additives in the production process of the material

VESTAreg is 100 recyclable with a perfect traceability it only contains virgin substances (no recycled

components for which establishing a traceability is impossible)

CLEANDoes not contain solvents adhesives or phthalates and does not generate

toxic emissions

STABLE AND RESISTANTVESTAreg fibres benefit from a thermal treatment which provides hydrophobic properties to the material The

formula reinforced with mineral resin lignin and antioxidants enables a remarkable mechanical resistance as

well as an outstanding design

The mineral pigments also offer a strong resistance to UV rays making the colours more durable whatever the

exposure

SOURCE

Raw material VESTAreg

X-FIRE is highly fire-resistant Wood fibres coming from sustainably managed European forests

Board Production France

COMPOSITIONby Volume 75 wood fibres mineral oil mineral salts mineral pigments

PHYSICAL PROPERTIES

Mass sqm COVER 6 195 kgmsup2 COVER 14 165 kgmsup2

Density 1500 kgm3

Parasite resistance Equivalent to use class 4 No development of fungal rot mosses or mould Insect-resistant including termites

Surface appearance Micro-striated surface splinter free blisters or flakes off Maintenance-free

Scratches resistance Equivalent to natural wood - Brushing possible without discolouration

Thermal inertia Low thermal inertia due to the high wood fibres content

ENVIRONMENTAL PROPERTIES

Recycling 100 recyclable 75 renewable and combustible (75 biomass)

Toxic substances Contains no toxic or dangerous products (according to Reach Regulation EC19072006)

Chemical fire retardant substance None

Solvents None

Heavy metals None lead-and mercury-free stabilization

Phthalates adhesives None

Formaldehydes and VOCs Lower than or equal to natural wood

VESTAreg REINFORCED WOOD FIBER

VESTA X-FIRE

ENVIRONMENTAL PRODUCT DECLARATION

1 - Values describing the environmental impacts

Owner of the declaration NEOLIFE Editor BUREAU VERITAS CODDE Declaration reference DEP_NEOLIFE_COVER_201507

Publication 10072015 Validity 10072020

Complies with the standard ISO 14025 NF EN 15804+A1 And itrsquos national addendum X P01-064CN

Environmental Declaration of the COVER productavailable on request

ENVIRONMENTAL PRODUCT DECLARATION

2 ndash Values describing the use of primary energetic sources other resources and water

3 ndash Complementary values describing the outflows

FURTHER DETAILS

33

TECHNICAL DESCRIPTION

French accreditaion type laquo Avis Technique Expeacuterimental de Type A raquo issued by CSTB (France)

Ndeg2278 ndash Available at httpevaluationcstbfrrechercherproduits-evaluesprestations=atex

VESTA Reinforced Wood Fiber cladding containing at least 75 wood fibres

Boards with a slatted aspect featuring 6 cm or 14 cm ribs

Fire rating with natural mineral salts following EN 13501-12007

COVER 6 B-s3-d0 minimum

COVER 14 B-s3-d0 minimum

Invisible fixing with stainless steel hooks screwed into wood or metal battens

Fast and accurate fitting thanks to the interlocking board system

Outside corners catered for by using 45deg miter cuts or aluminium corner profile

Dimensional stability of maximum 2mm m over ∆80degC

rot-proof not sensitive to moss and mould

Insect-resistant termites included

Stable colors after natural patina is acquired

Contact us to get the full technical specification sheet

CONTACT

CAUTION

This technical sheet is associated with the technical installation guide of CLAD claddingboard available at wwwneolife-solutionscom

NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters

disposal for any clarifications concerning the installation procedure of its products

The specifications and recommendations given in the installation guide are not a

substitute to regulations concerning safety environment and professional regulatory

dispositions

All instructions concerning the installation of our cladding are to be followed

Assembly errors are not covered by the NEOLIFEreg guarantee

An approved fitter shall be able to assess the construction conformity to the local

professional installation guidelines

304 Route Nationale 6 ndash Celtic Parc Bacirctiment Avalon II - 69760 Limonest FranceTel +33 (0)4 78 25 63 08 ndash Fax +33 (0)4 72 29 29 47

wwwneolife-solutionscom

Page 6: COVER 6 & 14 CLADDING · 2020. 11. 3. · 60 cm centre-to-centre spacing 10 / m ... sill and causes stains onto the cladding after raining WINDOW SILL Advice : Make a window sill

NATURAL COLOURS

Due to the inherent disparities in the standardisation of screens and printing inks the shades depicted onthis sheet may appear slightly different to those of the actual samples

EarthRAL 8019

OceanRAL 7046

SandRAL 1019

HeatRAL 8017

NightRAL 9004

RAL EQUIVALENCESAbove mentioned RAL colours are matching the best to VESTAreg eco-materialrsquos tint but can not be

considered as exactly similar The given indications are informative the responsibility lies with the

customer to determine whether the RAL color fits to its project or doesnrsquot

SunRAL 1011

SIX NATURAL COLOURS TINTED THROUGHOUT WITH MINERAL PIGMENTS(Informative RAL colours for accessories)

AGEING

bull VESTAreg is a natural material composed of wood fibres and mineral pigments giving the colour

bull In the first weeks the fibre will naturally tan and then lighten up to stabilize on the mineral end

colourbull Final patina will be achieved within 10 weeks in average

BOARDS AGEING PROCESS

The final patina will be obtained within 10 weeks the fibre will naturally tan and lighten up to reach the mineral pigmentrsquos tint

NIG

HT

OC

EacuteAN

SAN

DSU

NH

EAT

Day 1 Installation After 10 weeks

EAR

TH

PROFILES amp ACCESSORIES

References Products Profiles Dimension

BF4O325O5 Cover 6 - 4 waves Ocean

BF4O325H5 Cover 6 - 4 waves Heat

BF4O325S5 Cover 6 - 4 waves Sand

BF4O325U5 Cover 6 - 4 waves Sun

BF4O325N5 Cover 6 - 4 waves Night

BF4O325E5 Cover 6 - 4 waves Earth

BF2O325O5 Cover 14 - 2 waves Ocean

BF2O325H5 Cover 14 - 2 waves Heat

BF2O325S5 Cover 14 - 2 waves Sand

BF2O325U5 Cover 14 - 2 waves Sun

BF2O325N5 Cover 14 - 2 waves Night

BF2O325E5 Cover 14 - 2 waves Earth

CORNER PROFILEReferences Products Profiles Dimension

BAPA300O1 Aluminium Corner - pack of 2 pcs Ocean

BAPA300H1 Aluminium Corner - pack of 2 pcs Heat

BAPA300S1 Aluminium Corner - pack of 2 pcs Sand

BAPA300U1 Aluminium Corner - pack of 2 pcs Sun

BAPA300N1 Aluminium Corner - pack of 2 pcs Night

BAPA300E1 Aluminium Corner - pack of 2 pcs Earth

PIERCED STARTING PROFILEReferences Products Profiles Dimension

BAPD300A1 Pack of 5 Aluminium profiles - 2 mm thickness

300 x 43 x 4 cm(L x W x H)

Colours

COVER 6 amp COVER 14Colours

Colours

Neutral

325 x 30 x 285 cm(L x W x H)

1 pcs = 0975 sqm

325 x 30 x 285 cm(L x W x H)

1 pcs = 0975 sqm

300 x 6 x 6 cm(L x W x H)

FIXINGS

Number of hooks msup2 COVER 614

60 cm centre-to-centre spacing 10 msup2

40 cm 60 cm centre-to-centre spacing 15 msup2

FIXING HOOKSReferences Products Profiles Dimension

BFCR1PI2 Fixing Hook (50 units per bag) Stainless steel 37 x 19 x 15 cm(L x W x H)

A2 STAINLESS STEEL SCREWReferences

VIS BA RAL ndeg

VIS ME RAL ndeg Bi-metal Steel screw tinted head - Box of 500 units

48 x 21mm - Inox A2 A2 stainless steel

Wood amp Alu screw tinted head - Box of 500 units

42 x 32mm - Inox A2 A2 stainless steel

Colours

Products colours

RAL color

RAL color

- Ocean 7046 - Heat 8017- Sand 1019 - Sun 1011- Night 9004 - Earth 8019

- Ocean 7046 - Heat 8017- Sand 1019 - Sun 1011- Night 9004 - Earth 8019

VIS INOX A2 - A2 STAINLESS STEEL SCREW

VIS BA NdegRAL Laqueacutee RALRAL color

16 x 11 x 7 cm(L x l x H L x W x H ) 15kg

VIS ME NdegRAL Laqueacutee RALRAL color

16 x 11 x 7 cm(L x l x H L x W x H ) 15kg

Reference Profiles Dimcm Weight in kgProduct

Wood amp Alu screw tinted head - Box of 500 units

42 x 32mm - Inox A2 A2 stainless steel

Bi-metal Steel screw tinted head - Box of 500 units

48 x 21mm - Inox A2 A2 stainless steel

- Ocean 7046 - Heat 8017- Sand 1019 - Sun 1011- Night 9004 - Earth 8019

- Ocean 7046 - Heat 8017- Sand 1019 - Sun 1011- Night 9004 - Earth 8019

4kg

4kg

INSTALLATIONKEY PRINCIPLES

10

IMPLEMENTATION ON EXTERNAL THERMAL INSULATION

Horizontal fitting

Vertical fitting

TIMBER FRAME OR MASONRY (CONCRETE BRICKhellip) WALL WITH WOOD OR METAL BATTENS

Timber frame wall

Concrete wall

Timber frame wall

Concrete wall

Insulation

Insulation

IMPORTANT

Ensure the cladding is installedon ventilated battens minimumcross-section of wooden battens27x40 mm

Centre-to-centre spacing of 400to 600 mm depending on theimplementation area requiredlayout wind force or buildingheight

This batten framework can befixed on each wall type (woodmetal concrete etc) with orwithout exterior insulation

In all cases a minimum air gap of2 cm is required behind thecladding (check local regulations)

IMPLEMENTATION ON LINER TRAYS (INDUSTRIAL BUILDING ENVELLOPE)

Horinzontal fitting

IMPORTANT

Ensure the cladding is installed onventilated battens minimum cross-section of metal battens 20 x 40 mm

Centre-to-centre spacing of 400 to600 mm depending on theimplementation area required layout wind force or building height

This batten framework can be fixedon each wall type (wood metalconcrete etc) with or without exteriorinsulation

In all cases a minimum air gap of 2cm is required behind the cladding(check local regulations)

Steelstructure

Liner trays

Vertical fitting

Insulation

Insulation

Steelstructure

Liner trays

REMARQUES IMPORTANTES SUR LA POSE

BOARD PREPARATION Length 325 cm (tolerance of +0 20 mm)

Width 320 mm visible width when installed = 300mm (tolerance of plusmn 255 mm)

Thickness 285 mm (tolerance of plusmn 115 mm)

Squaring has to be done on site

Boards have to be calibrated according to layout

START Vertical installation Start with a metal or Aluminium profile It is highly recommended to install all the

boards in the same orientation in order to obtain a uniform colour Indeed the random brushing

creates an effect on the surface that capture the lights differently according the boards orientation

Pose horizontale Boards have to be installed with the groove at the bottom and the tongue at the top

IMPORTANT NOTICES

All instructions concerning the installation of our cladding are to be followed

Assembly errors are not covered by the NEOLIFEreg guarantee

An approved fitter shall be able to assess the construction conformity to the local

professional installation guidelines

Groove at the bottom

Horizontal intallation

Tongue at the top

Verticalinstallation

Profil alu de deacutepart visseacute

Screwed aluminium starting profile

REMARQUES IMPORTANTES SUR LA POSE

ALWAYS KEEP A 6 MM EXPANSION JOINT

A minimum space of 6mm between the 325m boards

and contiguous elements (joinery wall other cladding

boards) should be left to enable the natural expansion

of the NEOLIFEreg cladding boards

Always maintain 15 mm expansion per linear meter

(or 2mm in case of high temperature variations)

IMPORTANT NOTICES

NOT FOR STRUCTURAL USE Under no circumstances should the cladding boards be used for load-bearing or structural purposes

The professional rules and recommendations governing the cladding installation must be followed

NO SEALING PROPERTIES The boards are not designed to ensure the watertightness of the external facade

They should be used with a rainscreen wherever itrsquos required which will provide the weatherproofing

element in compliance with the local Building Regulations

FIXING ADDITIONAL ITEMS TO THE FACADE The cladding is not load-bearing

Anything fixed to the facade must be attached to the supporting structure behind the cladding

6mm

CAUTIONThe specifications and recommendations given in the NEOLIFEreg installation guide available at

wwwneolife-solutionscom website are not a substitute to regulations concerning safety

environment and regulatory installation specifications

REMARQUES IMPORTANTES SUR LA POSEIMPORTANT NOTICES

The panels have always to be fixed on each end at less than 1 cm of the boardrsquos edge

both in horizontal and vertical installations

EPDM strip

Concrete wall

1 Batten min size 60mmOr 2 battens min size 27x40mm

6 mm expansion joint

PREPARATION OF THE STRUCTURE

CAUTION

Make sure to respect the cladding installation steps recommended by the local professional guidelines

IMPORTANT ADVICES

The supporting structure (wood or metal) has to be perfectly flat to get a perfect facade The installation has to be planned on a ventilated wood structure with a minimum batten size of

27x40mm or on omega metal profiles 30x30x30 with a 400 ou 600 mm centre to centre distance

following the buildingrsquos category and height

The supporting structure can be fitted on every kind of walls (wood metal concrete) with or without

external insulation

Always keep a minimum 2cm air gap for ventilation behind the cladding (check the

recommendations of the local regulations )

The supporting structure has to be placed perpendicular to the cladding For vertical installation

the ventilation will be enabled through the claddingrsquos ribs or thanks to a crossed structure (following

the local recommendations)

Wide board With 300 mm width

KEY INSTALLATION PRINCIPLES

Mitre cut with perfectly aligned grooving

Horizontal or vertical fitting with various layouts

Invisible fixing using steel hooks screwed into the wood or metal supporting structures

Fast fixing using screwed steel hooks

NEOLIFEreg COVER claddingcan be fitted using all the conventional facade and covering accessories

Vertical fitting with a corner profile

6mm open expansion gapat the end of the board

Horizontal fittingwith a mitre cut

or with a corner profile

Metal CopingWindow revealwith metal profile

Outside corner or window reveal with Neolife corner profile

KEY INSTALLATION PRINCIPLES

DESIGN GUIDELINES

When the sign is installed onto the claddingwith no water runoff possibility It will cause stains on the claddingwhen drying (due to the mix of dust andpollution)

Flat metall elements without watertightnessmanagement Dirty water runoff causes stains

Advice

Leave space between cladding and the signand fix it on the load-bearing wall

INSTALLATION OF SHOP SIGN

OTHERS

Sign stuck onto the wall Sign away from the wall

Advice Install the element before the cladding bymanaging the waterlightness against the wallPlan a 10 slope and a waterdrop in order toavoid a water runoff onto the cladding

infiltration Seal and fixing

Cutting for expansion

Flat Casquette

Fixing againstthe wall

Absence of water drop Water drop

DESIGN GUIDELINES

BEST PRACTICEFind all the best practices in the NEOLIFEreg installation guide

available on our website wwwneolife-solutionscom

Closed metal profile at the junction betweencladding render no water runoffpossibility risk of stains and moisture on thestructure no ventilation

Flat window sill without water drop Dust and pollution collects on the windowsill and causes stains onto the cladding afterraining

WINDOW SILL

Advice Make a window sill with a 10 slopeminimum and a water drop with 30 mm gapfrom the cladding

Flat metal window sill

30mm

Advice Use a perforated metal ending profile and raise the cladding boards 5mm above the profile

no ventilation

Visible screwWater storage

Hidden screw

Perforated closure profile ventilation and water runoff

5mm

ENDINGS JUNCTIONS

Absence of water drop Water drop

REMARQUES IMPORTANTES SUR LA POSECAUTION

THE FULL INSTALLATION MANUAL OF COVER CLADDING PANELS IS AVAILABLE AT

wwwneolife-solutionscom

NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters

disposal for any clarifications concerning the installation procedure of its products

The specifications and recommendations given in the installation guide are not a

substitute to regulations concerning safety environment and professional regulatory

dispositions

All instructions concerning the installation of our cladding are to be followed

Assembly errors are not covered by the NEOLIFEreg guarantee

An approved fitter shall be able to assess the construction conformity to the local

professional installation guidelines

MAINTENANCE

21

Depending on the boards dirt after implementation (presence of mud dust etchellip) especially in the

grooves rain stains can appear on the surface

NEOLIFE strongly recommend to clean the boards after implementation with a pressure

washer following the boardsrsquo orientation (distance of min 20cm from the board DO NOT

USE a rotary nozzle)

Recommendations

Do not forget to clean the window shelves as well avoiding so any risk of dust stains on the

cladding after the first rain (windows are frequently dusty during construction)

All metal joineries (windows parapet capping etchellip) have to have a drip-edge flashing in

order to limit the water runoff on the cladding Shop signs or any other elements installed on

the cladding have to be moved forward (space left between cladding and the element) to

avoid any stains

Caution

If any operation involving the use of asphalt or concrete occurs after facade completion

NEOLIFE recommend to protect the cladding with a plastic cover in order to avoid stains

Indeed if not protected a greasy steam can spread on the surface and in the grooves In that

case a grease-removing product will be needed to clean the boards and all the surrounding

elements

BUILDING SITE CLEANING

LONG LASTING

VERY LIMITED MAINTENANCE

The material does not require any wood preservative (oils varnishes saturators hellip)

bull The VESTAreg material is naturally equivalent to use class 4(service environment In contact with ground or fresh water amp Permanently exposed to wetting The use classes rank the risk of exposure to decay and insect attack for differing in service environments according to EN 335 ndash 2)

bull Highly hydrophobic and rot-proof no algae fungi or moss development

bull Insect-resistant does not require any treatments against termites

STAIN REMOVAL

STAINS

Tanin stains

During the first weeks after installation tannin rings may occur because of the rain especially

on claddings with a light colour They will be washed off and fade during the next rain to

lessen until they completely disappear Be careful not to mistake these stains with dust or

pollution stains which appear on all cladding types

Bleach-based cleaning products

Slight discolouration Clean with water and complete if needed with slight brushing in the

boards orientation

Graffities oil paint and ink

Use a specialised stain remover (ex laquo STG 105 BIO raquo de STG)

Bitumen grease

Use a specialised stain remover (ex laquo Scalp Aqua 03 raquo)

Oxidation stains after contact with a corroded metal

Use a specialised wood de-greyer (ex laquo Scalp Neutral DA 66 raquo)

Caution

- Analyse properly the substance to clean so to use the right stain removing product

- Always test the stain removing product on a small and discrete surface before cleaning the

entire board

- It is mandatory that you analyse on a long time scale (and after exposure to Uvs) that the

solution you choose will not react with the cladding and therefore produce unsightly effects

DAMAGES

bull Scratches cigarette marks abrasion Brush away with a brass brush (lengthways)

TECHNICAL CHARACTERISTICS

25

SYSTEM PERFORMANCES

DESIGNATIONTEST

METHODS amp STANDARDS

CLADDING OUTLIFE COVER 6 amp 14

WIND LOAD (Depression) COVER 6 (4 ribs) COVER 14 (2 ribss)

Fixings description Eurocodes EN 1991-1-4 Test results Maximum shearing

pressure Test results Maximum shearingpressure

Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction

4 900 Pa

(degradation)140 kNm2 5 200 Pa

(degradation) 148 kNm2

Maximum 400mm centre-to-centre support spacing with one fixing tab at every junction 8 300 Pa (ruine) 237 kNm2 8 300 Pa (ruine) 237 kNm2

IMPACT RESISTANCE COVER 6 (4 ribs) COVER 14 (2 ribs)

Fixings description NF P 08302 Test results Test results

Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction

No damage with the impact energies below

Soft impacts 50Kg 130J

Soft impacts 3Kg 20J

Hard impacts 1Kg 3J

No damage with the impact energies below Soft impacts 50Kg 130J

Soft impacts 3Kg 20JHard impacts 1Kg 3J

SEISMIC RESISTANCE COVER 6 amp14

COVER 6 amp 14can be installed in seismic zones and buildings according to the following details

Highest seismic behaviour following Eurocode 8 no risk of falling boards or permanent deformations after static and dynamic test

FIRE RESISTANCE COVER 6 COVER 14

Tests description EN 13823 et EN 13501-12007

Fire rating

(on A2-s1d0 wall)

Fire rating

(on A2-s1d0 wall)

SBI test carried out on 3 models forming a 1500mm high 1000mm long and 500mm wide

dihedral wedge Assembly on air board and horizontal wood batten Valable contre un

substrat A2-s1d0

B-s3d0

Equivalent UK class 0

FIGRA average 1151Ws

THR average 6MJ

SMOGRA average 371 m2s2

B-s3d0

Equivalent UK class 0

FIGRA average 1924Ws

THR average 112MJ

SMOGRA average 592m2s2

Horizontal installation Class B-s3 d0 - Vertical installation on metal framework Class B s3 d0 on wooden framework Class C s3 d0 (EN 13501-12007)

PHYSICAL AND MECHANICAL FEATURES

DESIGNATION TEST METHODES amp STANDARDS COVER 6 amp 14 OUTLIFE CLADDING

FLAMMABLE MASS COVER 6 COVER 14Tests description NF EN 13238 Flammable mass per sqm (MJ)Tests realised according to the crucible method on at least 5 product samples 334 MJ 285 MJ

APPEARANCE DURABILITY(ageing under QUV) COVER 6 amp 14

Test descriptionNF EN 927-6 (2006)

FCBA‐ LBO6-PHY‐001

Test results

Artificial ageing test under QUV allowing an assessment of durability and decorative

properties modification Total duration 10 weeks comprising

condensation UV radiation and water spray phases

Stable products according to the EN 927-2

No blistering defects are observed according to ISO 4628-2 standard Resultt 0No cracking defects are observed according to ISO 4628-4 standard Result 0No flaking defects are observed according to ISO 4628-5 standard Result 0

THERMAL EXPANSION COVER 6 amp 14

Test description

ISO 11359-2 adapted to

FCBA - LBO6PHY-001

Test results

Thermodilatometric test in climatic room going from -20deg to +60deg to determine the profils

thermal expansion coefficient in solid state

Coefficient de dilatation thermique moyen

Longitudinally δL = 380 degK-1 10-6 standard spacing 210 degK-1 10-6 For uninstalled boardsTransversally δB = 575 degK-1 10-6 standard spacing 211 degK-1 10-6 For uninstalled boards

WATER UPTAKE DETERMINATION COVER 6 amp 14

Test description FCBA‐LBO‐MECA‐014 Test results

Water uptake determination after immersion in cold water during 28 days Measure of the

mass in its initial state and after 124714 et 28 days

Boards suitable to use in class 4 (Wood use class NF EN 335-2)Boards naturally resistant against fungus and soft rotAverage water uptake after 28 days 803Water content at 28 days and imputed to the cellulosic matter 143

ELASTICITY CONSTRAINS AND MODULE IN FLEXION COVER 6 amp 14

Test description

FCBA‐LBO‐MECA‐008

NF EN 310 modifiedWPC profiles

Test results

3 point flexion under normal conditions 20degCand 65 RH

Eaverage = 904 Nmm2fm = 40 Nmm2

ENVIRONMENTAL CHARACTERISTICS

28

VESTAreg ECO-MATERIAL

VESTAreg (Vegetal Ecological Stable Timber

Advantage) is an innovative and eco-friendly compound

with exceptional properties It was developed by

NEOCOreg NEOLIFEreglsquos Research Centre specialising in

green technologies in partnership with European experts

EXCEPTIONAL WOOD FIBER CONTENTVESTAreg revolutionises eco-materials and the design of

environmental solutions for construction projects and the

landscaping of outside spaces It finally brings a response

to the architects landscapers and design officesrsquo

demands working on eco-construction and sustainable

development projects

ECO-FRIENDLYThe wood fibres contained in VESTAreg come exclusively

from sawmills offcuts the wood coming from sustainably

managed European forests The production of our material

does not require the cutting of any trees and does not use treated wood from recycled pallets Moreover

NEOLIFE does not use any toxic additives in the production process of the material

VESTAreg is 100 recyclable with a perfect traceability it only contains virgin substances (no recycled

components for which establishing a traceability is impossible)

CLEANDoes not contain solvents adhesives or phthalates and does not generate

toxic emissions

STABLE AND RESISTANTVESTAreg fibres benefit from a thermal treatment which provides hydrophobic properties to the material The

formula reinforced with mineral resin lignin and antioxidants enables a remarkable mechanical resistance as

well as an outstanding design

The mineral pigments also offer a strong resistance to UV rays making the colours more durable whatever the

exposure

SOURCE

Raw material VESTAreg

X-FIRE is highly fire-resistant Wood fibres coming from sustainably managed European forests

Board Production France

COMPOSITIONby Volume 75 wood fibres mineral oil mineral salts mineral pigments

PHYSICAL PROPERTIES

Mass sqm COVER 6 195 kgmsup2 COVER 14 165 kgmsup2

Density 1500 kgm3

Parasite resistance Equivalent to use class 4 No development of fungal rot mosses or mould Insect-resistant including termites

Surface appearance Micro-striated surface splinter free blisters or flakes off Maintenance-free

Scratches resistance Equivalent to natural wood - Brushing possible without discolouration

Thermal inertia Low thermal inertia due to the high wood fibres content

ENVIRONMENTAL PROPERTIES

Recycling 100 recyclable 75 renewable and combustible (75 biomass)

Toxic substances Contains no toxic or dangerous products (according to Reach Regulation EC19072006)

Chemical fire retardant substance None

Solvents None

Heavy metals None lead-and mercury-free stabilization

Phthalates adhesives None

Formaldehydes and VOCs Lower than or equal to natural wood

VESTAreg REINFORCED WOOD FIBER

VESTA X-FIRE

ENVIRONMENTAL PRODUCT DECLARATION

1 - Values describing the environmental impacts

Owner of the declaration NEOLIFE Editor BUREAU VERITAS CODDE Declaration reference DEP_NEOLIFE_COVER_201507

Publication 10072015 Validity 10072020

Complies with the standard ISO 14025 NF EN 15804+A1 And itrsquos national addendum X P01-064CN

Environmental Declaration of the COVER productavailable on request

ENVIRONMENTAL PRODUCT DECLARATION

2 ndash Values describing the use of primary energetic sources other resources and water

3 ndash Complementary values describing the outflows

FURTHER DETAILS

33

TECHNICAL DESCRIPTION

French accreditaion type laquo Avis Technique Expeacuterimental de Type A raquo issued by CSTB (France)

Ndeg2278 ndash Available at httpevaluationcstbfrrechercherproduits-evaluesprestations=atex

VESTA Reinforced Wood Fiber cladding containing at least 75 wood fibres

Boards with a slatted aspect featuring 6 cm or 14 cm ribs

Fire rating with natural mineral salts following EN 13501-12007

COVER 6 B-s3-d0 minimum

COVER 14 B-s3-d0 minimum

Invisible fixing with stainless steel hooks screwed into wood or metal battens

Fast and accurate fitting thanks to the interlocking board system

Outside corners catered for by using 45deg miter cuts or aluminium corner profile

Dimensional stability of maximum 2mm m over ∆80degC

rot-proof not sensitive to moss and mould

Insect-resistant termites included

Stable colors after natural patina is acquired

Contact us to get the full technical specification sheet

CONTACT

CAUTION

This technical sheet is associated with the technical installation guide of CLAD claddingboard available at wwwneolife-solutionscom

NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters

disposal for any clarifications concerning the installation procedure of its products

The specifications and recommendations given in the installation guide are not a

substitute to regulations concerning safety environment and professional regulatory

dispositions

All instructions concerning the installation of our cladding are to be followed

Assembly errors are not covered by the NEOLIFEreg guarantee

An approved fitter shall be able to assess the construction conformity to the local

professional installation guidelines

304 Route Nationale 6 ndash Celtic Parc Bacirctiment Avalon II - 69760 Limonest FranceTel +33 (0)4 78 25 63 08 ndash Fax +33 (0)4 72 29 29 47

wwwneolife-solutionscom

Page 7: COVER 6 & 14 CLADDING · 2020. 11. 3. · 60 cm centre-to-centre spacing 10 / m ... sill and causes stains onto the cladding after raining WINDOW SILL Advice : Make a window sill

AGEING

bull VESTAreg is a natural material composed of wood fibres and mineral pigments giving the colour

bull In the first weeks the fibre will naturally tan and then lighten up to stabilize on the mineral end

colourbull Final patina will be achieved within 10 weeks in average

BOARDS AGEING PROCESS

The final patina will be obtained within 10 weeks the fibre will naturally tan and lighten up to reach the mineral pigmentrsquos tint

NIG

HT

OC

EacuteAN

SAN

DSU

NH

EAT

Day 1 Installation After 10 weeks

EAR

TH

PROFILES amp ACCESSORIES

References Products Profiles Dimension

BF4O325O5 Cover 6 - 4 waves Ocean

BF4O325H5 Cover 6 - 4 waves Heat

BF4O325S5 Cover 6 - 4 waves Sand

BF4O325U5 Cover 6 - 4 waves Sun

BF4O325N5 Cover 6 - 4 waves Night

BF4O325E5 Cover 6 - 4 waves Earth

BF2O325O5 Cover 14 - 2 waves Ocean

BF2O325H5 Cover 14 - 2 waves Heat

BF2O325S5 Cover 14 - 2 waves Sand

BF2O325U5 Cover 14 - 2 waves Sun

BF2O325N5 Cover 14 - 2 waves Night

BF2O325E5 Cover 14 - 2 waves Earth

CORNER PROFILEReferences Products Profiles Dimension

BAPA300O1 Aluminium Corner - pack of 2 pcs Ocean

BAPA300H1 Aluminium Corner - pack of 2 pcs Heat

BAPA300S1 Aluminium Corner - pack of 2 pcs Sand

BAPA300U1 Aluminium Corner - pack of 2 pcs Sun

BAPA300N1 Aluminium Corner - pack of 2 pcs Night

BAPA300E1 Aluminium Corner - pack of 2 pcs Earth

PIERCED STARTING PROFILEReferences Products Profiles Dimension

BAPD300A1 Pack of 5 Aluminium profiles - 2 mm thickness

300 x 43 x 4 cm(L x W x H)

Colours

COVER 6 amp COVER 14Colours

Colours

Neutral

325 x 30 x 285 cm(L x W x H)

1 pcs = 0975 sqm

325 x 30 x 285 cm(L x W x H)

1 pcs = 0975 sqm

300 x 6 x 6 cm(L x W x H)

FIXINGS

Number of hooks msup2 COVER 614

60 cm centre-to-centre spacing 10 msup2

40 cm 60 cm centre-to-centre spacing 15 msup2

FIXING HOOKSReferences Products Profiles Dimension

BFCR1PI2 Fixing Hook (50 units per bag) Stainless steel 37 x 19 x 15 cm(L x W x H)

A2 STAINLESS STEEL SCREWReferences

VIS BA RAL ndeg

VIS ME RAL ndeg Bi-metal Steel screw tinted head - Box of 500 units

48 x 21mm - Inox A2 A2 stainless steel

Wood amp Alu screw tinted head - Box of 500 units

42 x 32mm - Inox A2 A2 stainless steel

Colours

Products colours

RAL color

RAL color

- Ocean 7046 - Heat 8017- Sand 1019 - Sun 1011- Night 9004 - Earth 8019

- Ocean 7046 - Heat 8017- Sand 1019 - Sun 1011- Night 9004 - Earth 8019

VIS INOX A2 - A2 STAINLESS STEEL SCREW

VIS BA NdegRAL Laqueacutee RALRAL color

16 x 11 x 7 cm(L x l x H L x W x H ) 15kg

VIS ME NdegRAL Laqueacutee RALRAL color

16 x 11 x 7 cm(L x l x H L x W x H ) 15kg

Reference Profiles Dimcm Weight in kgProduct

Wood amp Alu screw tinted head - Box of 500 units

42 x 32mm - Inox A2 A2 stainless steel

Bi-metal Steel screw tinted head - Box of 500 units

48 x 21mm - Inox A2 A2 stainless steel

- Ocean 7046 - Heat 8017- Sand 1019 - Sun 1011- Night 9004 - Earth 8019

- Ocean 7046 - Heat 8017- Sand 1019 - Sun 1011- Night 9004 - Earth 8019

4kg

4kg

INSTALLATIONKEY PRINCIPLES

10

IMPLEMENTATION ON EXTERNAL THERMAL INSULATION

Horizontal fitting

Vertical fitting

TIMBER FRAME OR MASONRY (CONCRETE BRICKhellip) WALL WITH WOOD OR METAL BATTENS

Timber frame wall

Concrete wall

Timber frame wall

Concrete wall

Insulation

Insulation

IMPORTANT

Ensure the cladding is installedon ventilated battens minimumcross-section of wooden battens27x40 mm

Centre-to-centre spacing of 400to 600 mm depending on theimplementation area requiredlayout wind force or buildingheight

This batten framework can befixed on each wall type (woodmetal concrete etc) with orwithout exterior insulation

In all cases a minimum air gap of2 cm is required behind thecladding (check local regulations)

IMPLEMENTATION ON LINER TRAYS (INDUSTRIAL BUILDING ENVELLOPE)

Horinzontal fitting

IMPORTANT

Ensure the cladding is installed onventilated battens minimum cross-section of metal battens 20 x 40 mm

Centre-to-centre spacing of 400 to600 mm depending on theimplementation area required layout wind force or building height

This batten framework can be fixedon each wall type (wood metalconcrete etc) with or without exteriorinsulation

In all cases a minimum air gap of 2cm is required behind the cladding(check local regulations)

Steelstructure

Liner trays

Vertical fitting

Insulation

Insulation

Steelstructure

Liner trays

REMARQUES IMPORTANTES SUR LA POSE

BOARD PREPARATION Length 325 cm (tolerance of +0 20 mm)

Width 320 mm visible width when installed = 300mm (tolerance of plusmn 255 mm)

Thickness 285 mm (tolerance of plusmn 115 mm)

Squaring has to be done on site

Boards have to be calibrated according to layout

START Vertical installation Start with a metal or Aluminium profile It is highly recommended to install all the

boards in the same orientation in order to obtain a uniform colour Indeed the random brushing

creates an effect on the surface that capture the lights differently according the boards orientation

Pose horizontale Boards have to be installed with the groove at the bottom and the tongue at the top

IMPORTANT NOTICES

All instructions concerning the installation of our cladding are to be followed

Assembly errors are not covered by the NEOLIFEreg guarantee

An approved fitter shall be able to assess the construction conformity to the local

professional installation guidelines

Groove at the bottom

Horizontal intallation

Tongue at the top

Verticalinstallation

Profil alu de deacutepart visseacute

Screwed aluminium starting profile

REMARQUES IMPORTANTES SUR LA POSE

ALWAYS KEEP A 6 MM EXPANSION JOINT

A minimum space of 6mm between the 325m boards

and contiguous elements (joinery wall other cladding

boards) should be left to enable the natural expansion

of the NEOLIFEreg cladding boards

Always maintain 15 mm expansion per linear meter

(or 2mm in case of high temperature variations)

IMPORTANT NOTICES

NOT FOR STRUCTURAL USE Under no circumstances should the cladding boards be used for load-bearing or structural purposes

The professional rules and recommendations governing the cladding installation must be followed

NO SEALING PROPERTIES The boards are not designed to ensure the watertightness of the external facade

They should be used with a rainscreen wherever itrsquos required which will provide the weatherproofing

element in compliance with the local Building Regulations

FIXING ADDITIONAL ITEMS TO THE FACADE The cladding is not load-bearing

Anything fixed to the facade must be attached to the supporting structure behind the cladding

6mm

CAUTIONThe specifications and recommendations given in the NEOLIFEreg installation guide available at

wwwneolife-solutionscom website are not a substitute to regulations concerning safety

environment and regulatory installation specifications

REMARQUES IMPORTANTES SUR LA POSEIMPORTANT NOTICES

The panels have always to be fixed on each end at less than 1 cm of the boardrsquos edge

both in horizontal and vertical installations

EPDM strip

Concrete wall

1 Batten min size 60mmOr 2 battens min size 27x40mm

6 mm expansion joint

PREPARATION OF THE STRUCTURE

CAUTION

Make sure to respect the cladding installation steps recommended by the local professional guidelines

IMPORTANT ADVICES

The supporting structure (wood or metal) has to be perfectly flat to get a perfect facade The installation has to be planned on a ventilated wood structure with a minimum batten size of

27x40mm or on omega metal profiles 30x30x30 with a 400 ou 600 mm centre to centre distance

following the buildingrsquos category and height

The supporting structure can be fitted on every kind of walls (wood metal concrete) with or without

external insulation

Always keep a minimum 2cm air gap for ventilation behind the cladding (check the

recommendations of the local regulations )

The supporting structure has to be placed perpendicular to the cladding For vertical installation

the ventilation will be enabled through the claddingrsquos ribs or thanks to a crossed structure (following

the local recommendations)

Wide board With 300 mm width

KEY INSTALLATION PRINCIPLES

Mitre cut with perfectly aligned grooving

Horizontal or vertical fitting with various layouts

Invisible fixing using steel hooks screwed into the wood or metal supporting structures

Fast fixing using screwed steel hooks

NEOLIFEreg COVER claddingcan be fitted using all the conventional facade and covering accessories

Vertical fitting with a corner profile

6mm open expansion gapat the end of the board

Horizontal fittingwith a mitre cut

or with a corner profile

Metal CopingWindow revealwith metal profile

Outside corner or window reveal with Neolife corner profile

KEY INSTALLATION PRINCIPLES

DESIGN GUIDELINES

When the sign is installed onto the claddingwith no water runoff possibility It will cause stains on the claddingwhen drying (due to the mix of dust andpollution)

Flat metall elements without watertightnessmanagement Dirty water runoff causes stains

Advice

Leave space between cladding and the signand fix it on the load-bearing wall

INSTALLATION OF SHOP SIGN

OTHERS

Sign stuck onto the wall Sign away from the wall

Advice Install the element before the cladding bymanaging the waterlightness against the wallPlan a 10 slope and a waterdrop in order toavoid a water runoff onto the cladding

infiltration Seal and fixing

Cutting for expansion

Flat Casquette

Fixing againstthe wall

Absence of water drop Water drop

DESIGN GUIDELINES

BEST PRACTICEFind all the best practices in the NEOLIFEreg installation guide

available on our website wwwneolife-solutionscom

Closed metal profile at the junction betweencladding render no water runoffpossibility risk of stains and moisture on thestructure no ventilation

Flat window sill without water drop Dust and pollution collects on the windowsill and causes stains onto the cladding afterraining

WINDOW SILL

Advice Make a window sill with a 10 slopeminimum and a water drop with 30 mm gapfrom the cladding

Flat metal window sill

30mm

Advice Use a perforated metal ending profile and raise the cladding boards 5mm above the profile

no ventilation

Visible screwWater storage

Hidden screw

Perforated closure profile ventilation and water runoff

5mm

ENDINGS JUNCTIONS

Absence of water drop Water drop

REMARQUES IMPORTANTES SUR LA POSECAUTION

THE FULL INSTALLATION MANUAL OF COVER CLADDING PANELS IS AVAILABLE AT

wwwneolife-solutionscom

NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters

disposal for any clarifications concerning the installation procedure of its products

The specifications and recommendations given in the installation guide are not a

substitute to regulations concerning safety environment and professional regulatory

dispositions

All instructions concerning the installation of our cladding are to be followed

Assembly errors are not covered by the NEOLIFEreg guarantee

An approved fitter shall be able to assess the construction conformity to the local

professional installation guidelines

MAINTENANCE

21

Depending on the boards dirt after implementation (presence of mud dust etchellip) especially in the

grooves rain stains can appear on the surface

NEOLIFE strongly recommend to clean the boards after implementation with a pressure

washer following the boardsrsquo orientation (distance of min 20cm from the board DO NOT

USE a rotary nozzle)

Recommendations

Do not forget to clean the window shelves as well avoiding so any risk of dust stains on the

cladding after the first rain (windows are frequently dusty during construction)

All metal joineries (windows parapet capping etchellip) have to have a drip-edge flashing in

order to limit the water runoff on the cladding Shop signs or any other elements installed on

the cladding have to be moved forward (space left between cladding and the element) to

avoid any stains

Caution

If any operation involving the use of asphalt or concrete occurs after facade completion

NEOLIFE recommend to protect the cladding with a plastic cover in order to avoid stains

Indeed if not protected a greasy steam can spread on the surface and in the grooves In that

case a grease-removing product will be needed to clean the boards and all the surrounding

elements

BUILDING SITE CLEANING

LONG LASTING

VERY LIMITED MAINTENANCE

The material does not require any wood preservative (oils varnishes saturators hellip)

bull The VESTAreg material is naturally equivalent to use class 4(service environment In contact with ground or fresh water amp Permanently exposed to wetting The use classes rank the risk of exposure to decay and insect attack for differing in service environments according to EN 335 ndash 2)

bull Highly hydrophobic and rot-proof no algae fungi or moss development

bull Insect-resistant does not require any treatments against termites

STAIN REMOVAL

STAINS

Tanin stains

During the first weeks after installation tannin rings may occur because of the rain especially

on claddings with a light colour They will be washed off and fade during the next rain to

lessen until they completely disappear Be careful not to mistake these stains with dust or

pollution stains which appear on all cladding types

Bleach-based cleaning products

Slight discolouration Clean with water and complete if needed with slight brushing in the

boards orientation

Graffities oil paint and ink

Use a specialised stain remover (ex laquo STG 105 BIO raquo de STG)

Bitumen grease

Use a specialised stain remover (ex laquo Scalp Aqua 03 raquo)

Oxidation stains after contact with a corroded metal

Use a specialised wood de-greyer (ex laquo Scalp Neutral DA 66 raquo)

Caution

- Analyse properly the substance to clean so to use the right stain removing product

- Always test the stain removing product on a small and discrete surface before cleaning the

entire board

- It is mandatory that you analyse on a long time scale (and after exposure to Uvs) that the

solution you choose will not react with the cladding and therefore produce unsightly effects

DAMAGES

bull Scratches cigarette marks abrasion Brush away with a brass brush (lengthways)

TECHNICAL CHARACTERISTICS

25

SYSTEM PERFORMANCES

DESIGNATIONTEST

METHODS amp STANDARDS

CLADDING OUTLIFE COVER 6 amp 14

WIND LOAD (Depression) COVER 6 (4 ribs) COVER 14 (2 ribss)

Fixings description Eurocodes EN 1991-1-4 Test results Maximum shearing

pressure Test results Maximum shearingpressure

Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction

4 900 Pa

(degradation)140 kNm2 5 200 Pa

(degradation) 148 kNm2

Maximum 400mm centre-to-centre support spacing with one fixing tab at every junction 8 300 Pa (ruine) 237 kNm2 8 300 Pa (ruine) 237 kNm2

IMPACT RESISTANCE COVER 6 (4 ribs) COVER 14 (2 ribs)

Fixings description NF P 08302 Test results Test results

Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction

No damage with the impact energies below

Soft impacts 50Kg 130J

Soft impacts 3Kg 20J

Hard impacts 1Kg 3J

No damage with the impact energies below Soft impacts 50Kg 130J

Soft impacts 3Kg 20JHard impacts 1Kg 3J

SEISMIC RESISTANCE COVER 6 amp14

COVER 6 amp 14can be installed in seismic zones and buildings according to the following details

Highest seismic behaviour following Eurocode 8 no risk of falling boards or permanent deformations after static and dynamic test

FIRE RESISTANCE COVER 6 COVER 14

Tests description EN 13823 et EN 13501-12007

Fire rating

(on A2-s1d0 wall)

Fire rating

(on A2-s1d0 wall)

SBI test carried out on 3 models forming a 1500mm high 1000mm long and 500mm wide

dihedral wedge Assembly on air board and horizontal wood batten Valable contre un

substrat A2-s1d0

B-s3d0

Equivalent UK class 0

FIGRA average 1151Ws

THR average 6MJ

SMOGRA average 371 m2s2

B-s3d0

Equivalent UK class 0

FIGRA average 1924Ws

THR average 112MJ

SMOGRA average 592m2s2

Horizontal installation Class B-s3 d0 - Vertical installation on metal framework Class B s3 d0 on wooden framework Class C s3 d0 (EN 13501-12007)

PHYSICAL AND MECHANICAL FEATURES

DESIGNATION TEST METHODES amp STANDARDS COVER 6 amp 14 OUTLIFE CLADDING

FLAMMABLE MASS COVER 6 COVER 14Tests description NF EN 13238 Flammable mass per sqm (MJ)Tests realised according to the crucible method on at least 5 product samples 334 MJ 285 MJ

APPEARANCE DURABILITY(ageing under QUV) COVER 6 amp 14

Test descriptionNF EN 927-6 (2006)

FCBA‐ LBO6-PHY‐001

Test results

Artificial ageing test under QUV allowing an assessment of durability and decorative

properties modification Total duration 10 weeks comprising

condensation UV radiation and water spray phases

Stable products according to the EN 927-2

No blistering defects are observed according to ISO 4628-2 standard Resultt 0No cracking defects are observed according to ISO 4628-4 standard Result 0No flaking defects are observed according to ISO 4628-5 standard Result 0

THERMAL EXPANSION COVER 6 amp 14

Test description

ISO 11359-2 adapted to

FCBA - LBO6PHY-001

Test results

Thermodilatometric test in climatic room going from -20deg to +60deg to determine the profils

thermal expansion coefficient in solid state

Coefficient de dilatation thermique moyen

Longitudinally δL = 380 degK-1 10-6 standard spacing 210 degK-1 10-6 For uninstalled boardsTransversally δB = 575 degK-1 10-6 standard spacing 211 degK-1 10-6 For uninstalled boards

WATER UPTAKE DETERMINATION COVER 6 amp 14

Test description FCBA‐LBO‐MECA‐014 Test results

Water uptake determination after immersion in cold water during 28 days Measure of the

mass in its initial state and after 124714 et 28 days

Boards suitable to use in class 4 (Wood use class NF EN 335-2)Boards naturally resistant against fungus and soft rotAverage water uptake after 28 days 803Water content at 28 days and imputed to the cellulosic matter 143

ELASTICITY CONSTRAINS AND MODULE IN FLEXION COVER 6 amp 14

Test description

FCBA‐LBO‐MECA‐008

NF EN 310 modifiedWPC profiles

Test results

3 point flexion under normal conditions 20degCand 65 RH

Eaverage = 904 Nmm2fm = 40 Nmm2

ENVIRONMENTAL CHARACTERISTICS

28

VESTAreg ECO-MATERIAL

VESTAreg (Vegetal Ecological Stable Timber

Advantage) is an innovative and eco-friendly compound

with exceptional properties It was developed by

NEOCOreg NEOLIFEreglsquos Research Centre specialising in

green technologies in partnership with European experts

EXCEPTIONAL WOOD FIBER CONTENTVESTAreg revolutionises eco-materials and the design of

environmental solutions for construction projects and the

landscaping of outside spaces It finally brings a response

to the architects landscapers and design officesrsquo

demands working on eco-construction and sustainable

development projects

ECO-FRIENDLYThe wood fibres contained in VESTAreg come exclusively

from sawmills offcuts the wood coming from sustainably

managed European forests The production of our material

does not require the cutting of any trees and does not use treated wood from recycled pallets Moreover

NEOLIFE does not use any toxic additives in the production process of the material

VESTAreg is 100 recyclable with a perfect traceability it only contains virgin substances (no recycled

components for which establishing a traceability is impossible)

CLEANDoes not contain solvents adhesives or phthalates and does not generate

toxic emissions

STABLE AND RESISTANTVESTAreg fibres benefit from a thermal treatment which provides hydrophobic properties to the material The

formula reinforced with mineral resin lignin and antioxidants enables a remarkable mechanical resistance as

well as an outstanding design

The mineral pigments also offer a strong resistance to UV rays making the colours more durable whatever the

exposure

SOURCE

Raw material VESTAreg

X-FIRE is highly fire-resistant Wood fibres coming from sustainably managed European forests

Board Production France

COMPOSITIONby Volume 75 wood fibres mineral oil mineral salts mineral pigments

PHYSICAL PROPERTIES

Mass sqm COVER 6 195 kgmsup2 COVER 14 165 kgmsup2

Density 1500 kgm3

Parasite resistance Equivalent to use class 4 No development of fungal rot mosses or mould Insect-resistant including termites

Surface appearance Micro-striated surface splinter free blisters or flakes off Maintenance-free

Scratches resistance Equivalent to natural wood - Brushing possible without discolouration

Thermal inertia Low thermal inertia due to the high wood fibres content

ENVIRONMENTAL PROPERTIES

Recycling 100 recyclable 75 renewable and combustible (75 biomass)

Toxic substances Contains no toxic or dangerous products (according to Reach Regulation EC19072006)

Chemical fire retardant substance None

Solvents None

Heavy metals None lead-and mercury-free stabilization

Phthalates adhesives None

Formaldehydes and VOCs Lower than or equal to natural wood

VESTAreg REINFORCED WOOD FIBER

VESTA X-FIRE

ENVIRONMENTAL PRODUCT DECLARATION

1 - Values describing the environmental impacts

Owner of the declaration NEOLIFE Editor BUREAU VERITAS CODDE Declaration reference DEP_NEOLIFE_COVER_201507

Publication 10072015 Validity 10072020

Complies with the standard ISO 14025 NF EN 15804+A1 And itrsquos national addendum X P01-064CN

Environmental Declaration of the COVER productavailable on request

ENVIRONMENTAL PRODUCT DECLARATION

2 ndash Values describing the use of primary energetic sources other resources and water

3 ndash Complementary values describing the outflows

FURTHER DETAILS

33

TECHNICAL DESCRIPTION

French accreditaion type laquo Avis Technique Expeacuterimental de Type A raquo issued by CSTB (France)

Ndeg2278 ndash Available at httpevaluationcstbfrrechercherproduits-evaluesprestations=atex

VESTA Reinforced Wood Fiber cladding containing at least 75 wood fibres

Boards with a slatted aspect featuring 6 cm or 14 cm ribs

Fire rating with natural mineral salts following EN 13501-12007

COVER 6 B-s3-d0 minimum

COVER 14 B-s3-d0 minimum

Invisible fixing with stainless steel hooks screwed into wood or metal battens

Fast and accurate fitting thanks to the interlocking board system

Outside corners catered for by using 45deg miter cuts or aluminium corner profile

Dimensional stability of maximum 2mm m over ∆80degC

rot-proof not sensitive to moss and mould

Insect-resistant termites included

Stable colors after natural patina is acquired

Contact us to get the full technical specification sheet

CONTACT

CAUTION

This technical sheet is associated with the technical installation guide of CLAD claddingboard available at wwwneolife-solutionscom

NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters

disposal for any clarifications concerning the installation procedure of its products

The specifications and recommendations given in the installation guide are not a

substitute to regulations concerning safety environment and professional regulatory

dispositions

All instructions concerning the installation of our cladding are to be followed

Assembly errors are not covered by the NEOLIFEreg guarantee

An approved fitter shall be able to assess the construction conformity to the local

professional installation guidelines

304 Route Nationale 6 ndash Celtic Parc Bacirctiment Avalon II - 69760 Limonest FranceTel +33 (0)4 78 25 63 08 ndash Fax +33 (0)4 72 29 29 47

wwwneolife-solutionscom

Page 8: COVER 6 & 14 CLADDING · 2020. 11. 3. · 60 cm centre-to-centre spacing 10 / m ... sill and causes stains onto the cladding after raining WINDOW SILL Advice : Make a window sill

PROFILES amp ACCESSORIES

References Products Profiles Dimension

BF4O325O5 Cover 6 - 4 waves Ocean

BF4O325H5 Cover 6 - 4 waves Heat

BF4O325S5 Cover 6 - 4 waves Sand

BF4O325U5 Cover 6 - 4 waves Sun

BF4O325N5 Cover 6 - 4 waves Night

BF4O325E5 Cover 6 - 4 waves Earth

BF2O325O5 Cover 14 - 2 waves Ocean

BF2O325H5 Cover 14 - 2 waves Heat

BF2O325S5 Cover 14 - 2 waves Sand

BF2O325U5 Cover 14 - 2 waves Sun

BF2O325N5 Cover 14 - 2 waves Night

BF2O325E5 Cover 14 - 2 waves Earth

CORNER PROFILEReferences Products Profiles Dimension

BAPA300O1 Aluminium Corner - pack of 2 pcs Ocean

BAPA300H1 Aluminium Corner - pack of 2 pcs Heat

BAPA300S1 Aluminium Corner - pack of 2 pcs Sand

BAPA300U1 Aluminium Corner - pack of 2 pcs Sun

BAPA300N1 Aluminium Corner - pack of 2 pcs Night

BAPA300E1 Aluminium Corner - pack of 2 pcs Earth

PIERCED STARTING PROFILEReferences Products Profiles Dimension

BAPD300A1 Pack of 5 Aluminium profiles - 2 mm thickness

300 x 43 x 4 cm(L x W x H)

Colours

COVER 6 amp COVER 14Colours

Colours

Neutral

325 x 30 x 285 cm(L x W x H)

1 pcs = 0975 sqm

325 x 30 x 285 cm(L x W x H)

1 pcs = 0975 sqm

300 x 6 x 6 cm(L x W x H)

FIXINGS

Number of hooks msup2 COVER 614

60 cm centre-to-centre spacing 10 msup2

40 cm 60 cm centre-to-centre spacing 15 msup2

FIXING HOOKSReferences Products Profiles Dimension

BFCR1PI2 Fixing Hook (50 units per bag) Stainless steel 37 x 19 x 15 cm(L x W x H)

A2 STAINLESS STEEL SCREWReferences

VIS BA RAL ndeg

VIS ME RAL ndeg Bi-metal Steel screw tinted head - Box of 500 units

48 x 21mm - Inox A2 A2 stainless steel

Wood amp Alu screw tinted head - Box of 500 units

42 x 32mm - Inox A2 A2 stainless steel

Colours

Products colours

RAL color

RAL color

- Ocean 7046 - Heat 8017- Sand 1019 - Sun 1011- Night 9004 - Earth 8019

- Ocean 7046 - Heat 8017- Sand 1019 - Sun 1011- Night 9004 - Earth 8019

VIS INOX A2 - A2 STAINLESS STEEL SCREW

VIS BA NdegRAL Laqueacutee RALRAL color

16 x 11 x 7 cm(L x l x H L x W x H ) 15kg

VIS ME NdegRAL Laqueacutee RALRAL color

16 x 11 x 7 cm(L x l x H L x W x H ) 15kg

Reference Profiles Dimcm Weight in kgProduct

Wood amp Alu screw tinted head - Box of 500 units

42 x 32mm - Inox A2 A2 stainless steel

Bi-metal Steel screw tinted head - Box of 500 units

48 x 21mm - Inox A2 A2 stainless steel

- Ocean 7046 - Heat 8017- Sand 1019 - Sun 1011- Night 9004 - Earth 8019

- Ocean 7046 - Heat 8017- Sand 1019 - Sun 1011- Night 9004 - Earth 8019

4kg

4kg

INSTALLATIONKEY PRINCIPLES

10

IMPLEMENTATION ON EXTERNAL THERMAL INSULATION

Horizontal fitting

Vertical fitting

TIMBER FRAME OR MASONRY (CONCRETE BRICKhellip) WALL WITH WOOD OR METAL BATTENS

Timber frame wall

Concrete wall

Timber frame wall

Concrete wall

Insulation

Insulation

IMPORTANT

Ensure the cladding is installedon ventilated battens minimumcross-section of wooden battens27x40 mm

Centre-to-centre spacing of 400to 600 mm depending on theimplementation area requiredlayout wind force or buildingheight

This batten framework can befixed on each wall type (woodmetal concrete etc) with orwithout exterior insulation

In all cases a minimum air gap of2 cm is required behind thecladding (check local regulations)

IMPLEMENTATION ON LINER TRAYS (INDUSTRIAL BUILDING ENVELLOPE)

Horinzontal fitting

IMPORTANT

Ensure the cladding is installed onventilated battens minimum cross-section of metal battens 20 x 40 mm

Centre-to-centre spacing of 400 to600 mm depending on theimplementation area required layout wind force or building height

This batten framework can be fixedon each wall type (wood metalconcrete etc) with or without exteriorinsulation

In all cases a minimum air gap of 2cm is required behind the cladding(check local regulations)

Steelstructure

Liner trays

Vertical fitting

Insulation

Insulation

Steelstructure

Liner trays

REMARQUES IMPORTANTES SUR LA POSE

BOARD PREPARATION Length 325 cm (tolerance of +0 20 mm)

Width 320 mm visible width when installed = 300mm (tolerance of plusmn 255 mm)

Thickness 285 mm (tolerance of plusmn 115 mm)

Squaring has to be done on site

Boards have to be calibrated according to layout

START Vertical installation Start with a metal or Aluminium profile It is highly recommended to install all the

boards in the same orientation in order to obtain a uniform colour Indeed the random brushing

creates an effect on the surface that capture the lights differently according the boards orientation

Pose horizontale Boards have to be installed with the groove at the bottom and the tongue at the top

IMPORTANT NOTICES

All instructions concerning the installation of our cladding are to be followed

Assembly errors are not covered by the NEOLIFEreg guarantee

An approved fitter shall be able to assess the construction conformity to the local

professional installation guidelines

Groove at the bottom

Horizontal intallation

Tongue at the top

Verticalinstallation

Profil alu de deacutepart visseacute

Screwed aluminium starting profile

REMARQUES IMPORTANTES SUR LA POSE

ALWAYS KEEP A 6 MM EXPANSION JOINT

A minimum space of 6mm between the 325m boards

and contiguous elements (joinery wall other cladding

boards) should be left to enable the natural expansion

of the NEOLIFEreg cladding boards

Always maintain 15 mm expansion per linear meter

(or 2mm in case of high temperature variations)

IMPORTANT NOTICES

NOT FOR STRUCTURAL USE Under no circumstances should the cladding boards be used for load-bearing or structural purposes

The professional rules and recommendations governing the cladding installation must be followed

NO SEALING PROPERTIES The boards are not designed to ensure the watertightness of the external facade

They should be used with a rainscreen wherever itrsquos required which will provide the weatherproofing

element in compliance with the local Building Regulations

FIXING ADDITIONAL ITEMS TO THE FACADE The cladding is not load-bearing

Anything fixed to the facade must be attached to the supporting structure behind the cladding

6mm

CAUTIONThe specifications and recommendations given in the NEOLIFEreg installation guide available at

wwwneolife-solutionscom website are not a substitute to regulations concerning safety

environment and regulatory installation specifications

REMARQUES IMPORTANTES SUR LA POSEIMPORTANT NOTICES

The panels have always to be fixed on each end at less than 1 cm of the boardrsquos edge

both in horizontal and vertical installations

EPDM strip

Concrete wall

1 Batten min size 60mmOr 2 battens min size 27x40mm

6 mm expansion joint

PREPARATION OF THE STRUCTURE

CAUTION

Make sure to respect the cladding installation steps recommended by the local professional guidelines

IMPORTANT ADVICES

The supporting structure (wood or metal) has to be perfectly flat to get a perfect facade The installation has to be planned on a ventilated wood structure with a minimum batten size of

27x40mm or on omega metal profiles 30x30x30 with a 400 ou 600 mm centre to centre distance

following the buildingrsquos category and height

The supporting structure can be fitted on every kind of walls (wood metal concrete) with or without

external insulation

Always keep a minimum 2cm air gap for ventilation behind the cladding (check the

recommendations of the local regulations )

The supporting structure has to be placed perpendicular to the cladding For vertical installation

the ventilation will be enabled through the claddingrsquos ribs or thanks to a crossed structure (following

the local recommendations)

Wide board With 300 mm width

KEY INSTALLATION PRINCIPLES

Mitre cut with perfectly aligned grooving

Horizontal or vertical fitting with various layouts

Invisible fixing using steel hooks screwed into the wood or metal supporting structures

Fast fixing using screwed steel hooks

NEOLIFEreg COVER claddingcan be fitted using all the conventional facade and covering accessories

Vertical fitting with a corner profile

6mm open expansion gapat the end of the board

Horizontal fittingwith a mitre cut

or with a corner profile

Metal CopingWindow revealwith metal profile

Outside corner or window reveal with Neolife corner profile

KEY INSTALLATION PRINCIPLES

DESIGN GUIDELINES

When the sign is installed onto the claddingwith no water runoff possibility It will cause stains on the claddingwhen drying (due to the mix of dust andpollution)

Flat metall elements without watertightnessmanagement Dirty water runoff causes stains

Advice

Leave space between cladding and the signand fix it on the load-bearing wall

INSTALLATION OF SHOP SIGN

OTHERS

Sign stuck onto the wall Sign away from the wall

Advice Install the element before the cladding bymanaging the waterlightness against the wallPlan a 10 slope and a waterdrop in order toavoid a water runoff onto the cladding

infiltration Seal and fixing

Cutting for expansion

Flat Casquette

Fixing againstthe wall

Absence of water drop Water drop

DESIGN GUIDELINES

BEST PRACTICEFind all the best practices in the NEOLIFEreg installation guide

available on our website wwwneolife-solutionscom

Closed metal profile at the junction betweencladding render no water runoffpossibility risk of stains and moisture on thestructure no ventilation

Flat window sill without water drop Dust and pollution collects on the windowsill and causes stains onto the cladding afterraining

WINDOW SILL

Advice Make a window sill with a 10 slopeminimum and a water drop with 30 mm gapfrom the cladding

Flat metal window sill

30mm

Advice Use a perforated metal ending profile and raise the cladding boards 5mm above the profile

no ventilation

Visible screwWater storage

Hidden screw

Perforated closure profile ventilation and water runoff

5mm

ENDINGS JUNCTIONS

Absence of water drop Water drop

REMARQUES IMPORTANTES SUR LA POSECAUTION

THE FULL INSTALLATION MANUAL OF COVER CLADDING PANELS IS AVAILABLE AT

wwwneolife-solutionscom

NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters

disposal for any clarifications concerning the installation procedure of its products

The specifications and recommendations given in the installation guide are not a

substitute to regulations concerning safety environment and professional regulatory

dispositions

All instructions concerning the installation of our cladding are to be followed

Assembly errors are not covered by the NEOLIFEreg guarantee

An approved fitter shall be able to assess the construction conformity to the local

professional installation guidelines

MAINTENANCE

21

Depending on the boards dirt after implementation (presence of mud dust etchellip) especially in the

grooves rain stains can appear on the surface

NEOLIFE strongly recommend to clean the boards after implementation with a pressure

washer following the boardsrsquo orientation (distance of min 20cm from the board DO NOT

USE a rotary nozzle)

Recommendations

Do not forget to clean the window shelves as well avoiding so any risk of dust stains on the

cladding after the first rain (windows are frequently dusty during construction)

All metal joineries (windows parapet capping etchellip) have to have a drip-edge flashing in

order to limit the water runoff on the cladding Shop signs or any other elements installed on

the cladding have to be moved forward (space left between cladding and the element) to

avoid any stains

Caution

If any operation involving the use of asphalt or concrete occurs after facade completion

NEOLIFE recommend to protect the cladding with a plastic cover in order to avoid stains

Indeed if not protected a greasy steam can spread on the surface and in the grooves In that

case a grease-removing product will be needed to clean the boards and all the surrounding

elements

BUILDING SITE CLEANING

LONG LASTING

VERY LIMITED MAINTENANCE

The material does not require any wood preservative (oils varnishes saturators hellip)

bull The VESTAreg material is naturally equivalent to use class 4(service environment In contact with ground or fresh water amp Permanently exposed to wetting The use classes rank the risk of exposure to decay and insect attack for differing in service environments according to EN 335 ndash 2)

bull Highly hydrophobic and rot-proof no algae fungi or moss development

bull Insect-resistant does not require any treatments against termites

STAIN REMOVAL

STAINS

Tanin stains

During the first weeks after installation tannin rings may occur because of the rain especially

on claddings with a light colour They will be washed off and fade during the next rain to

lessen until they completely disappear Be careful not to mistake these stains with dust or

pollution stains which appear on all cladding types

Bleach-based cleaning products

Slight discolouration Clean with water and complete if needed with slight brushing in the

boards orientation

Graffities oil paint and ink

Use a specialised stain remover (ex laquo STG 105 BIO raquo de STG)

Bitumen grease

Use a specialised stain remover (ex laquo Scalp Aqua 03 raquo)

Oxidation stains after contact with a corroded metal

Use a specialised wood de-greyer (ex laquo Scalp Neutral DA 66 raquo)

Caution

- Analyse properly the substance to clean so to use the right stain removing product

- Always test the stain removing product on a small and discrete surface before cleaning the

entire board

- It is mandatory that you analyse on a long time scale (and after exposure to Uvs) that the

solution you choose will not react with the cladding and therefore produce unsightly effects

DAMAGES

bull Scratches cigarette marks abrasion Brush away with a brass brush (lengthways)

TECHNICAL CHARACTERISTICS

25

SYSTEM PERFORMANCES

DESIGNATIONTEST

METHODS amp STANDARDS

CLADDING OUTLIFE COVER 6 amp 14

WIND LOAD (Depression) COVER 6 (4 ribs) COVER 14 (2 ribss)

Fixings description Eurocodes EN 1991-1-4 Test results Maximum shearing

pressure Test results Maximum shearingpressure

Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction

4 900 Pa

(degradation)140 kNm2 5 200 Pa

(degradation) 148 kNm2

Maximum 400mm centre-to-centre support spacing with one fixing tab at every junction 8 300 Pa (ruine) 237 kNm2 8 300 Pa (ruine) 237 kNm2

IMPACT RESISTANCE COVER 6 (4 ribs) COVER 14 (2 ribs)

Fixings description NF P 08302 Test results Test results

Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction

No damage with the impact energies below

Soft impacts 50Kg 130J

Soft impacts 3Kg 20J

Hard impacts 1Kg 3J

No damage with the impact energies below Soft impacts 50Kg 130J

Soft impacts 3Kg 20JHard impacts 1Kg 3J

SEISMIC RESISTANCE COVER 6 amp14

COVER 6 amp 14can be installed in seismic zones and buildings according to the following details

Highest seismic behaviour following Eurocode 8 no risk of falling boards or permanent deformations after static and dynamic test

FIRE RESISTANCE COVER 6 COVER 14

Tests description EN 13823 et EN 13501-12007

Fire rating

(on A2-s1d0 wall)

Fire rating

(on A2-s1d0 wall)

SBI test carried out on 3 models forming a 1500mm high 1000mm long and 500mm wide

dihedral wedge Assembly on air board and horizontal wood batten Valable contre un

substrat A2-s1d0

B-s3d0

Equivalent UK class 0

FIGRA average 1151Ws

THR average 6MJ

SMOGRA average 371 m2s2

B-s3d0

Equivalent UK class 0

FIGRA average 1924Ws

THR average 112MJ

SMOGRA average 592m2s2

Horizontal installation Class B-s3 d0 - Vertical installation on metal framework Class B s3 d0 on wooden framework Class C s3 d0 (EN 13501-12007)

PHYSICAL AND MECHANICAL FEATURES

DESIGNATION TEST METHODES amp STANDARDS COVER 6 amp 14 OUTLIFE CLADDING

FLAMMABLE MASS COVER 6 COVER 14Tests description NF EN 13238 Flammable mass per sqm (MJ)Tests realised according to the crucible method on at least 5 product samples 334 MJ 285 MJ

APPEARANCE DURABILITY(ageing under QUV) COVER 6 amp 14

Test descriptionNF EN 927-6 (2006)

FCBA‐ LBO6-PHY‐001

Test results

Artificial ageing test under QUV allowing an assessment of durability and decorative

properties modification Total duration 10 weeks comprising

condensation UV radiation and water spray phases

Stable products according to the EN 927-2

No blistering defects are observed according to ISO 4628-2 standard Resultt 0No cracking defects are observed according to ISO 4628-4 standard Result 0No flaking defects are observed according to ISO 4628-5 standard Result 0

THERMAL EXPANSION COVER 6 amp 14

Test description

ISO 11359-2 adapted to

FCBA - LBO6PHY-001

Test results

Thermodilatometric test in climatic room going from -20deg to +60deg to determine the profils

thermal expansion coefficient in solid state

Coefficient de dilatation thermique moyen

Longitudinally δL = 380 degK-1 10-6 standard spacing 210 degK-1 10-6 For uninstalled boardsTransversally δB = 575 degK-1 10-6 standard spacing 211 degK-1 10-6 For uninstalled boards

WATER UPTAKE DETERMINATION COVER 6 amp 14

Test description FCBA‐LBO‐MECA‐014 Test results

Water uptake determination after immersion in cold water during 28 days Measure of the

mass in its initial state and after 124714 et 28 days

Boards suitable to use in class 4 (Wood use class NF EN 335-2)Boards naturally resistant against fungus and soft rotAverage water uptake after 28 days 803Water content at 28 days and imputed to the cellulosic matter 143

ELASTICITY CONSTRAINS AND MODULE IN FLEXION COVER 6 amp 14

Test description

FCBA‐LBO‐MECA‐008

NF EN 310 modifiedWPC profiles

Test results

3 point flexion under normal conditions 20degCand 65 RH

Eaverage = 904 Nmm2fm = 40 Nmm2

ENVIRONMENTAL CHARACTERISTICS

28

VESTAreg ECO-MATERIAL

VESTAreg (Vegetal Ecological Stable Timber

Advantage) is an innovative and eco-friendly compound

with exceptional properties It was developed by

NEOCOreg NEOLIFEreglsquos Research Centre specialising in

green technologies in partnership with European experts

EXCEPTIONAL WOOD FIBER CONTENTVESTAreg revolutionises eco-materials and the design of

environmental solutions for construction projects and the

landscaping of outside spaces It finally brings a response

to the architects landscapers and design officesrsquo

demands working on eco-construction and sustainable

development projects

ECO-FRIENDLYThe wood fibres contained in VESTAreg come exclusively

from sawmills offcuts the wood coming from sustainably

managed European forests The production of our material

does not require the cutting of any trees and does not use treated wood from recycled pallets Moreover

NEOLIFE does not use any toxic additives in the production process of the material

VESTAreg is 100 recyclable with a perfect traceability it only contains virgin substances (no recycled

components for which establishing a traceability is impossible)

CLEANDoes not contain solvents adhesives or phthalates and does not generate

toxic emissions

STABLE AND RESISTANTVESTAreg fibres benefit from a thermal treatment which provides hydrophobic properties to the material The

formula reinforced with mineral resin lignin and antioxidants enables a remarkable mechanical resistance as

well as an outstanding design

The mineral pigments also offer a strong resistance to UV rays making the colours more durable whatever the

exposure

SOURCE

Raw material VESTAreg

X-FIRE is highly fire-resistant Wood fibres coming from sustainably managed European forests

Board Production France

COMPOSITIONby Volume 75 wood fibres mineral oil mineral salts mineral pigments

PHYSICAL PROPERTIES

Mass sqm COVER 6 195 kgmsup2 COVER 14 165 kgmsup2

Density 1500 kgm3

Parasite resistance Equivalent to use class 4 No development of fungal rot mosses or mould Insect-resistant including termites

Surface appearance Micro-striated surface splinter free blisters or flakes off Maintenance-free

Scratches resistance Equivalent to natural wood - Brushing possible without discolouration

Thermal inertia Low thermal inertia due to the high wood fibres content

ENVIRONMENTAL PROPERTIES

Recycling 100 recyclable 75 renewable and combustible (75 biomass)

Toxic substances Contains no toxic or dangerous products (according to Reach Regulation EC19072006)

Chemical fire retardant substance None

Solvents None

Heavy metals None lead-and mercury-free stabilization

Phthalates adhesives None

Formaldehydes and VOCs Lower than or equal to natural wood

VESTAreg REINFORCED WOOD FIBER

VESTA X-FIRE

ENVIRONMENTAL PRODUCT DECLARATION

1 - Values describing the environmental impacts

Owner of the declaration NEOLIFE Editor BUREAU VERITAS CODDE Declaration reference DEP_NEOLIFE_COVER_201507

Publication 10072015 Validity 10072020

Complies with the standard ISO 14025 NF EN 15804+A1 And itrsquos national addendum X P01-064CN

Environmental Declaration of the COVER productavailable on request

ENVIRONMENTAL PRODUCT DECLARATION

2 ndash Values describing the use of primary energetic sources other resources and water

3 ndash Complementary values describing the outflows

FURTHER DETAILS

33

TECHNICAL DESCRIPTION

French accreditaion type laquo Avis Technique Expeacuterimental de Type A raquo issued by CSTB (France)

Ndeg2278 ndash Available at httpevaluationcstbfrrechercherproduits-evaluesprestations=atex

VESTA Reinforced Wood Fiber cladding containing at least 75 wood fibres

Boards with a slatted aspect featuring 6 cm or 14 cm ribs

Fire rating with natural mineral salts following EN 13501-12007

COVER 6 B-s3-d0 minimum

COVER 14 B-s3-d0 minimum

Invisible fixing with stainless steel hooks screwed into wood or metal battens

Fast and accurate fitting thanks to the interlocking board system

Outside corners catered for by using 45deg miter cuts or aluminium corner profile

Dimensional stability of maximum 2mm m over ∆80degC

rot-proof not sensitive to moss and mould

Insect-resistant termites included

Stable colors after natural patina is acquired

Contact us to get the full technical specification sheet

CONTACT

CAUTION

This technical sheet is associated with the technical installation guide of CLAD claddingboard available at wwwneolife-solutionscom

NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters

disposal for any clarifications concerning the installation procedure of its products

The specifications and recommendations given in the installation guide are not a

substitute to regulations concerning safety environment and professional regulatory

dispositions

All instructions concerning the installation of our cladding are to be followed

Assembly errors are not covered by the NEOLIFEreg guarantee

An approved fitter shall be able to assess the construction conformity to the local

professional installation guidelines

304 Route Nationale 6 ndash Celtic Parc Bacirctiment Avalon II - 69760 Limonest FranceTel +33 (0)4 78 25 63 08 ndash Fax +33 (0)4 72 29 29 47

wwwneolife-solutionscom

Page 9: COVER 6 & 14 CLADDING · 2020. 11. 3. · 60 cm centre-to-centre spacing 10 / m ... sill and causes stains onto the cladding after raining WINDOW SILL Advice : Make a window sill

FIXINGS

Number of hooks msup2 COVER 614

60 cm centre-to-centre spacing 10 msup2

40 cm 60 cm centre-to-centre spacing 15 msup2

FIXING HOOKSReferences Products Profiles Dimension

BFCR1PI2 Fixing Hook (50 units per bag) Stainless steel 37 x 19 x 15 cm(L x W x H)

A2 STAINLESS STEEL SCREWReferences

VIS BA RAL ndeg

VIS ME RAL ndeg Bi-metal Steel screw tinted head - Box of 500 units

48 x 21mm - Inox A2 A2 stainless steel

Wood amp Alu screw tinted head - Box of 500 units

42 x 32mm - Inox A2 A2 stainless steel

Colours

Products colours

RAL color

RAL color

- Ocean 7046 - Heat 8017- Sand 1019 - Sun 1011- Night 9004 - Earth 8019

- Ocean 7046 - Heat 8017- Sand 1019 - Sun 1011- Night 9004 - Earth 8019

VIS INOX A2 - A2 STAINLESS STEEL SCREW

VIS BA NdegRAL Laqueacutee RALRAL color

16 x 11 x 7 cm(L x l x H L x W x H ) 15kg

VIS ME NdegRAL Laqueacutee RALRAL color

16 x 11 x 7 cm(L x l x H L x W x H ) 15kg

Reference Profiles Dimcm Weight in kgProduct

Wood amp Alu screw tinted head - Box of 500 units

42 x 32mm - Inox A2 A2 stainless steel

Bi-metal Steel screw tinted head - Box of 500 units

48 x 21mm - Inox A2 A2 stainless steel

- Ocean 7046 - Heat 8017- Sand 1019 - Sun 1011- Night 9004 - Earth 8019

- Ocean 7046 - Heat 8017- Sand 1019 - Sun 1011- Night 9004 - Earth 8019

4kg

4kg

INSTALLATIONKEY PRINCIPLES

10

IMPLEMENTATION ON EXTERNAL THERMAL INSULATION

Horizontal fitting

Vertical fitting

TIMBER FRAME OR MASONRY (CONCRETE BRICKhellip) WALL WITH WOOD OR METAL BATTENS

Timber frame wall

Concrete wall

Timber frame wall

Concrete wall

Insulation

Insulation

IMPORTANT

Ensure the cladding is installedon ventilated battens minimumcross-section of wooden battens27x40 mm

Centre-to-centre spacing of 400to 600 mm depending on theimplementation area requiredlayout wind force or buildingheight

This batten framework can befixed on each wall type (woodmetal concrete etc) with orwithout exterior insulation

In all cases a minimum air gap of2 cm is required behind thecladding (check local regulations)

IMPLEMENTATION ON LINER TRAYS (INDUSTRIAL BUILDING ENVELLOPE)

Horinzontal fitting

IMPORTANT

Ensure the cladding is installed onventilated battens minimum cross-section of metal battens 20 x 40 mm

Centre-to-centre spacing of 400 to600 mm depending on theimplementation area required layout wind force or building height

This batten framework can be fixedon each wall type (wood metalconcrete etc) with or without exteriorinsulation

In all cases a minimum air gap of 2cm is required behind the cladding(check local regulations)

Steelstructure

Liner trays

Vertical fitting

Insulation

Insulation

Steelstructure

Liner trays

REMARQUES IMPORTANTES SUR LA POSE

BOARD PREPARATION Length 325 cm (tolerance of +0 20 mm)

Width 320 mm visible width when installed = 300mm (tolerance of plusmn 255 mm)

Thickness 285 mm (tolerance of plusmn 115 mm)

Squaring has to be done on site

Boards have to be calibrated according to layout

START Vertical installation Start with a metal or Aluminium profile It is highly recommended to install all the

boards in the same orientation in order to obtain a uniform colour Indeed the random brushing

creates an effect on the surface that capture the lights differently according the boards orientation

Pose horizontale Boards have to be installed with the groove at the bottom and the tongue at the top

IMPORTANT NOTICES

All instructions concerning the installation of our cladding are to be followed

Assembly errors are not covered by the NEOLIFEreg guarantee

An approved fitter shall be able to assess the construction conformity to the local

professional installation guidelines

Groove at the bottom

Horizontal intallation

Tongue at the top

Verticalinstallation

Profil alu de deacutepart visseacute

Screwed aluminium starting profile

REMARQUES IMPORTANTES SUR LA POSE

ALWAYS KEEP A 6 MM EXPANSION JOINT

A minimum space of 6mm between the 325m boards

and contiguous elements (joinery wall other cladding

boards) should be left to enable the natural expansion

of the NEOLIFEreg cladding boards

Always maintain 15 mm expansion per linear meter

(or 2mm in case of high temperature variations)

IMPORTANT NOTICES

NOT FOR STRUCTURAL USE Under no circumstances should the cladding boards be used for load-bearing or structural purposes

The professional rules and recommendations governing the cladding installation must be followed

NO SEALING PROPERTIES The boards are not designed to ensure the watertightness of the external facade

They should be used with a rainscreen wherever itrsquos required which will provide the weatherproofing

element in compliance with the local Building Regulations

FIXING ADDITIONAL ITEMS TO THE FACADE The cladding is not load-bearing

Anything fixed to the facade must be attached to the supporting structure behind the cladding

6mm

CAUTIONThe specifications and recommendations given in the NEOLIFEreg installation guide available at

wwwneolife-solutionscom website are not a substitute to regulations concerning safety

environment and regulatory installation specifications

REMARQUES IMPORTANTES SUR LA POSEIMPORTANT NOTICES

The panels have always to be fixed on each end at less than 1 cm of the boardrsquos edge

both in horizontal and vertical installations

EPDM strip

Concrete wall

1 Batten min size 60mmOr 2 battens min size 27x40mm

6 mm expansion joint

PREPARATION OF THE STRUCTURE

CAUTION

Make sure to respect the cladding installation steps recommended by the local professional guidelines

IMPORTANT ADVICES

The supporting structure (wood or metal) has to be perfectly flat to get a perfect facade The installation has to be planned on a ventilated wood structure with a minimum batten size of

27x40mm or on omega metal profiles 30x30x30 with a 400 ou 600 mm centre to centre distance

following the buildingrsquos category and height

The supporting structure can be fitted on every kind of walls (wood metal concrete) with or without

external insulation

Always keep a minimum 2cm air gap for ventilation behind the cladding (check the

recommendations of the local regulations )

The supporting structure has to be placed perpendicular to the cladding For vertical installation

the ventilation will be enabled through the claddingrsquos ribs or thanks to a crossed structure (following

the local recommendations)

Wide board With 300 mm width

KEY INSTALLATION PRINCIPLES

Mitre cut with perfectly aligned grooving

Horizontal or vertical fitting with various layouts

Invisible fixing using steel hooks screwed into the wood or metal supporting structures

Fast fixing using screwed steel hooks

NEOLIFEreg COVER claddingcan be fitted using all the conventional facade and covering accessories

Vertical fitting with a corner profile

6mm open expansion gapat the end of the board

Horizontal fittingwith a mitre cut

or with a corner profile

Metal CopingWindow revealwith metal profile

Outside corner or window reveal with Neolife corner profile

KEY INSTALLATION PRINCIPLES

DESIGN GUIDELINES

When the sign is installed onto the claddingwith no water runoff possibility It will cause stains on the claddingwhen drying (due to the mix of dust andpollution)

Flat metall elements without watertightnessmanagement Dirty water runoff causes stains

Advice

Leave space between cladding and the signand fix it on the load-bearing wall

INSTALLATION OF SHOP SIGN

OTHERS

Sign stuck onto the wall Sign away from the wall

Advice Install the element before the cladding bymanaging the waterlightness against the wallPlan a 10 slope and a waterdrop in order toavoid a water runoff onto the cladding

infiltration Seal and fixing

Cutting for expansion

Flat Casquette

Fixing againstthe wall

Absence of water drop Water drop

DESIGN GUIDELINES

BEST PRACTICEFind all the best practices in the NEOLIFEreg installation guide

available on our website wwwneolife-solutionscom

Closed metal profile at the junction betweencladding render no water runoffpossibility risk of stains and moisture on thestructure no ventilation

Flat window sill without water drop Dust and pollution collects on the windowsill and causes stains onto the cladding afterraining

WINDOW SILL

Advice Make a window sill with a 10 slopeminimum and a water drop with 30 mm gapfrom the cladding

Flat metal window sill

30mm

Advice Use a perforated metal ending profile and raise the cladding boards 5mm above the profile

no ventilation

Visible screwWater storage

Hidden screw

Perforated closure profile ventilation and water runoff

5mm

ENDINGS JUNCTIONS

Absence of water drop Water drop

REMARQUES IMPORTANTES SUR LA POSECAUTION

THE FULL INSTALLATION MANUAL OF COVER CLADDING PANELS IS AVAILABLE AT

wwwneolife-solutionscom

NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters

disposal for any clarifications concerning the installation procedure of its products

The specifications and recommendations given in the installation guide are not a

substitute to regulations concerning safety environment and professional regulatory

dispositions

All instructions concerning the installation of our cladding are to be followed

Assembly errors are not covered by the NEOLIFEreg guarantee

An approved fitter shall be able to assess the construction conformity to the local

professional installation guidelines

MAINTENANCE

21

Depending on the boards dirt after implementation (presence of mud dust etchellip) especially in the

grooves rain stains can appear on the surface

NEOLIFE strongly recommend to clean the boards after implementation with a pressure

washer following the boardsrsquo orientation (distance of min 20cm from the board DO NOT

USE a rotary nozzle)

Recommendations

Do not forget to clean the window shelves as well avoiding so any risk of dust stains on the

cladding after the first rain (windows are frequently dusty during construction)

All metal joineries (windows parapet capping etchellip) have to have a drip-edge flashing in

order to limit the water runoff on the cladding Shop signs or any other elements installed on

the cladding have to be moved forward (space left between cladding and the element) to

avoid any stains

Caution

If any operation involving the use of asphalt or concrete occurs after facade completion

NEOLIFE recommend to protect the cladding with a plastic cover in order to avoid stains

Indeed if not protected a greasy steam can spread on the surface and in the grooves In that

case a grease-removing product will be needed to clean the boards and all the surrounding

elements

BUILDING SITE CLEANING

LONG LASTING

VERY LIMITED MAINTENANCE

The material does not require any wood preservative (oils varnishes saturators hellip)

bull The VESTAreg material is naturally equivalent to use class 4(service environment In contact with ground or fresh water amp Permanently exposed to wetting The use classes rank the risk of exposure to decay and insect attack for differing in service environments according to EN 335 ndash 2)

bull Highly hydrophobic and rot-proof no algae fungi or moss development

bull Insect-resistant does not require any treatments against termites

STAIN REMOVAL

STAINS

Tanin stains

During the first weeks after installation tannin rings may occur because of the rain especially

on claddings with a light colour They will be washed off and fade during the next rain to

lessen until they completely disappear Be careful not to mistake these stains with dust or

pollution stains which appear on all cladding types

Bleach-based cleaning products

Slight discolouration Clean with water and complete if needed with slight brushing in the

boards orientation

Graffities oil paint and ink

Use a specialised stain remover (ex laquo STG 105 BIO raquo de STG)

Bitumen grease

Use a specialised stain remover (ex laquo Scalp Aqua 03 raquo)

Oxidation stains after contact with a corroded metal

Use a specialised wood de-greyer (ex laquo Scalp Neutral DA 66 raquo)

Caution

- Analyse properly the substance to clean so to use the right stain removing product

- Always test the stain removing product on a small and discrete surface before cleaning the

entire board

- It is mandatory that you analyse on a long time scale (and after exposure to Uvs) that the

solution you choose will not react with the cladding and therefore produce unsightly effects

DAMAGES

bull Scratches cigarette marks abrasion Brush away with a brass brush (lengthways)

TECHNICAL CHARACTERISTICS

25

SYSTEM PERFORMANCES

DESIGNATIONTEST

METHODS amp STANDARDS

CLADDING OUTLIFE COVER 6 amp 14

WIND LOAD (Depression) COVER 6 (4 ribs) COVER 14 (2 ribss)

Fixings description Eurocodes EN 1991-1-4 Test results Maximum shearing

pressure Test results Maximum shearingpressure

Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction

4 900 Pa

(degradation)140 kNm2 5 200 Pa

(degradation) 148 kNm2

Maximum 400mm centre-to-centre support spacing with one fixing tab at every junction 8 300 Pa (ruine) 237 kNm2 8 300 Pa (ruine) 237 kNm2

IMPACT RESISTANCE COVER 6 (4 ribs) COVER 14 (2 ribs)

Fixings description NF P 08302 Test results Test results

Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction

No damage with the impact energies below

Soft impacts 50Kg 130J

Soft impacts 3Kg 20J

Hard impacts 1Kg 3J

No damage with the impact energies below Soft impacts 50Kg 130J

Soft impacts 3Kg 20JHard impacts 1Kg 3J

SEISMIC RESISTANCE COVER 6 amp14

COVER 6 amp 14can be installed in seismic zones and buildings according to the following details

Highest seismic behaviour following Eurocode 8 no risk of falling boards or permanent deformations after static and dynamic test

FIRE RESISTANCE COVER 6 COVER 14

Tests description EN 13823 et EN 13501-12007

Fire rating

(on A2-s1d0 wall)

Fire rating

(on A2-s1d0 wall)

SBI test carried out on 3 models forming a 1500mm high 1000mm long and 500mm wide

dihedral wedge Assembly on air board and horizontal wood batten Valable contre un

substrat A2-s1d0

B-s3d0

Equivalent UK class 0

FIGRA average 1151Ws

THR average 6MJ

SMOGRA average 371 m2s2

B-s3d0

Equivalent UK class 0

FIGRA average 1924Ws

THR average 112MJ

SMOGRA average 592m2s2

Horizontal installation Class B-s3 d0 - Vertical installation on metal framework Class B s3 d0 on wooden framework Class C s3 d0 (EN 13501-12007)

PHYSICAL AND MECHANICAL FEATURES

DESIGNATION TEST METHODES amp STANDARDS COVER 6 amp 14 OUTLIFE CLADDING

FLAMMABLE MASS COVER 6 COVER 14Tests description NF EN 13238 Flammable mass per sqm (MJ)Tests realised according to the crucible method on at least 5 product samples 334 MJ 285 MJ

APPEARANCE DURABILITY(ageing under QUV) COVER 6 amp 14

Test descriptionNF EN 927-6 (2006)

FCBA‐ LBO6-PHY‐001

Test results

Artificial ageing test under QUV allowing an assessment of durability and decorative

properties modification Total duration 10 weeks comprising

condensation UV radiation and water spray phases

Stable products according to the EN 927-2

No blistering defects are observed according to ISO 4628-2 standard Resultt 0No cracking defects are observed according to ISO 4628-4 standard Result 0No flaking defects are observed according to ISO 4628-5 standard Result 0

THERMAL EXPANSION COVER 6 amp 14

Test description

ISO 11359-2 adapted to

FCBA - LBO6PHY-001

Test results

Thermodilatometric test in climatic room going from -20deg to +60deg to determine the profils

thermal expansion coefficient in solid state

Coefficient de dilatation thermique moyen

Longitudinally δL = 380 degK-1 10-6 standard spacing 210 degK-1 10-6 For uninstalled boardsTransversally δB = 575 degK-1 10-6 standard spacing 211 degK-1 10-6 For uninstalled boards

WATER UPTAKE DETERMINATION COVER 6 amp 14

Test description FCBA‐LBO‐MECA‐014 Test results

Water uptake determination after immersion in cold water during 28 days Measure of the

mass in its initial state and after 124714 et 28 days

Boards suitable to use in class 4 (Wood use class NF EN 335-2)Boards naturally resistant against fungus and soft rotAverage water uptake after 28 days 803Water content at 28 days and imputed to the cellulosic matter 143

ELASTICITY CONSTRAINS AND MODULE IN FLEXION COVER 6 amp 14

Test description

FCBA‐LBO‐MECA‐008

NF EN 310 modifiedWPC profiles

Test results

3 point flexion under normal conditions 20degCand 65 RH

Eaverage = 904 Nmm2fm = 40 Nmm2

ENVIRONMENTAL CHARACTERISTICS

28

VESTAreg ECO-MATERIAL

VESTAreg (Vegetal Ecological Stable Timber

Advantage) is an innovative and eco-friendly compound

with exceptional properties It was developed by

NEOCOreg NEOLIFEreglsquos Research Centre specialising in

green technologies in partnership with European experts

EXCEPTIONAL WOOD FIBER CONTENTVESTAreg revolutionises eco-materials and the design of

environmental solutions for construction projects and the

landscaping of outside spaces It finally brings a response

to the architects landscapers and design officesrsquo

demands working on eco-construction and sustainable

development projects

ECO-FRIENDLYThe wood fibres contained in VESTAreg come exclusively

from sawmills offcuts the wood coming from sustainably

managed European forests The production of our material

does not require the cutting of any trees and does not use treated wood from recycled pallets Moreover

NEOLIFE does not use any toxic additives in the production process of the material

VESTAreg is 100 recyclable with a perfect traceability it only contains virgin substances (no recycled

components for which establishing a traceability is impossible)

CLEANDoes not contain solvents adhesives or phthalates and does not generate

toxic emissions

STABLE AND RESISTANTVESTAreg fibres benefit from a thermal treatment which provides hydrophobic properties to the material The

formula reinforced with mineral resin lignin and antioxidants enables a remarkable mechanical resistance as

well as an outstanding design

The mineral pigments also offer a strong resistance to UV rays making the colours more durable whatever the

exposure

SOURCE

Raw material VESTAreg

X-FIRE is highly fire-resistant Wood fibres coming from sustainably managed European forests

Board Production France

COMPOSITIONby Volume 75 wood fibres mineral oil mineral salts mineral pigments

PHYSICAL PROPERTIES

Mass sqm COVER 6 195 kgmsup2 COVER 14 165 kgmsup2

Density 1500 kgm3

Parasite resistance Equivalent to use class 4 No development of fungal rot mosses or mould Insect-resistant including termites

Surface appearance Micro-striated surface splinter free blisters or flakes off Maintenance-free

Scratches resistance Equivalent to natural wood - Brushing possible without discolouration

Thermal inertia Low thermal inertia due to the high wood fibres content

ENVIRONMENTAL PROPERTIES

Recycling 100 recyclable 75 renewable and combustible (75 biomass)

Toxic substances Contains no toxic or dangerous products (according to Reach Regulation EC19072006)

Chemical fire retardant substance None

Solvents None

Heavy metals None lead-and mercury-free stabilization

Phthalates adhesives None

Formaldehydes and VOCs Lower than or equal to natural wood

VESTAreg REINFORCED WOOD FIBER

VESTA X-FIRE

ENVIRONMENTAL PRODUCT DECLARATION

1 - Values describing the environmental impacts

Owner of the declaration NEOLIFE Editor BUREAU VERITAS CODDE Declaration reference DEP_NEOLIFE_COVER_201507

Publication 10072015 Validity 10072020

Complies with the standard ISO 14025 NF EN 15804+A1 And itrsquos national addendum X P01-064CN

Environmental Declaration of the COVER productavailable on request

ENVIRONMENTAL PRODUCT DECLARATION

2 ndash Values describing the use of primary energetic sources other resources and water

3 ndash Complementary values describing the outflows

FURTHER DETAILS

33

TECHNICAL DESCRIPTION

French accreditaion type laquo Avis Technique Expeacuterimental de Type A raquo issued by CSTB (France)

Ndeg2278 ndash Available at httpevaluationcstbfrrechercherproduits-evaluesprestations=atex

VESTA Reinforced Wood Fiber cladding containing at least 75 wood fibres

Boards with a slatted aspect featuring 6 cm or 14 cm ribs

Fire rating with natural mineral salts following EN 13501-12007

COVER 6 B-s3-d0 minimum

COVER 14 B-s3-d0 minimum

Invisible fixing with stainless steel hooks screwed into wood or metal battens

Fast and accurate fitting thanks to the interlocking board system

Outside corners catered for by using 45deg miter cuts or aluminium corner profile

Dimensional stability of maximum 2mm m over ∆80degC

rot-proof not sensitive to moss and mould

Insect-resistant termites included

Stable colors after natural patina is acquired

Contact us to get the full technical specification sheet

CONTACT

CAUTION

This technical sheet is associated with the technical installation guide of CLAD claddingboard available at wwwneolife-solutionscom

NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters

disposal for any clarifications concerning the installation procedure of its products

The specifications and recommendations given in the installation guide are not a

substitute to regulations concerning safety environment and professional regulatory

dispositions

All instructions concerning the installation of our cladding are to be followed

Assembly errors are not covered by the NEOLIFEreg guarantee

An approved fitter shall be able to assess the construction conformity to the local

professional installation guidelines

304 Route Nationale 6 ndash Celtic Parc Bacirctiment Avalon II - 69760 Limonest FranceTel +33 (0)4 78 25 63 08 ndash Fax +33 (0)4 72 29 29 47

wwwneolife-solutionscom

Page 10: COVER 6 & 14 CLADDING · 2020. 11. 3. · 60 cm centre-to-centre spacing 10 / m ... sill and causes stains onto the cladding after raining WINDOW SILL Advice : Make a window sill

INSTALLATIONKEY PRINCIPLES

10

IMPLEMENTATION ON EXTERNAL THERMAL INSULATION

Horizontal fitting

Vertical fitting

TIMBER FRAME OR MASONRY (CONCRETE BRICKhellip) WALL WITH WOOD OR METAL BATTENS

Timber frame wall

Concrete wall

Timber frame wall

Concrete wall

Insulation

Insulation

IMPORTANT

Ensure the cladding is installedon ventilated battens minimumcross-section of wooden battens27x40 mm

Centre-to-centre spacing of 400to 600 mm depending on theimplementation area requiredlayout wind force or buildingheight

This batten framework can befixed on each wall type (woodmetal concrete etc) with orwithout exterior insulation

In all cases a minimum air gap of2 cm is required behind thecladding (check local regulations)

IMPLEMENTATION ON LINER TRAYS (INDUSTRIAL BUILDING ENVELLOPE)

Horinzontal fitting

IMPORTANT

Ensure the cladding is installed onventilated battens minimum cross-section of metal battens 20 x 40 mm

Centre-to-centre spacing of 400 to600 mm depending on theimplementation area required layout wind force or building height

This batten framework can be fixedon each wall type (wood metalconcrete etc) with or without exteriorinsulation

In all cases a minimum air gap of 2cm is required behind the cladding(check local regulations)

Steelstructure

Liner trays

Vertical fitting

Insulation

Insulation

Steelstructure

Liner trays

REMARQUES IMPORTANTES SUR LA POSE

BOARD PREPARATION Length 325 cm (tolerance of +0 20 mm)

Width 320 mm visible width when installed = 300mm (tolerance of plusmn 255 mm)

Thickness 285 mm (tolerance of plusmn 115 mm)

Squaring has to be done on site

Boards have to be calibrated according to layout

START Vertical installation Start with a metal or Aluminium profile It is highly recommended to install all the

boards in the same orientation in order to obtain a uniform colour Indeed the random brushing

creates an effect on the surface that capture the lights differently according the boards orientation

Pose horizontale Boards have to be installed with the groove at the bottom and the tongue at the top

IMPORTANT NOTICES

All instructions concerning the installation of our cladding are to be followed

Assembly errors are not covered by the NEOLIFEreg guarantee

An approved fitter shall be able to assess the construction conformity to the local

professional installation guidelines

Groove at the bottom

Horizontal intallation

Tongue at the top

Verticalinstallation

Profil alu de deacutepart visseacute

Screwed aluminium starting profile

REMARQUES IMPORTANTES SUR LA POSE

ALWAYS KEEP A 6 MM EXPANSION JOINT

A minimum space of 6mm between the 325m boards

and contiguous elements (joinery wall other cladding

boards) should be left to enable the natural expansion

of the NEOLIFEreg cladding boards

Always maintain 15 mm expansion per linear meter

(or 2mm in case of high temperature variations)

IMPORTANT NOTICES

NOT FOR STRUCTURAL USE Under no circumstances should the cladding boards be used for load-bearing or structural purposes

The professional rules and recommendations governing the cladding installation must be followed

NO SEALING PROPERTIES The boards are not designed to ensure the watertightness of the external facade

They should be used with a rainscreen wherever itrsquos required which will provide the weatherproofing

element in compliance with the local Building Regulations

FIXING ADDITIONAL ITEMS TO THE FACADE The cladding is not load-bearing

Anything fixed to the facade must be attached to the supporting structure behind the cladding

6mm

CAUTIONThe specifications and recommendations given in the NEOLIFEreg installation guide available at

wwwneolife-solutionscom website are not a substitute to regulations concerning safety

environment and regulatory installation specifications

REMARQUES IMPORTANTES SUR LA POSEIMPORTANT NOTICES

The panels have always to be fixed on each end at less than 1 cm of the boardrsquos edge

both in horizontal and vertical installations

EPDM strip

Concrete wall

1 Batten min size 60mmOr 2 battens min size 27x40mm

6 mm expansion joint

PREPARATION OF THE STRUCTURE

CAUTION

Make sure to respect the cladding installation steps recommended by the local professional guidelines

IMPORTANT ADVICES

The supporting structure (wood or metal) has to be perfectly flat to get a perfect facade The installation has to be planned on a ventilated wood structure with a minimum batten size of

27x40mm or on omega metal profiles 30x30x30 with a 400 ou 600 mm centre to centre distance

following the buildingrsquos category and height

The supporting structure can be fitted on every kind of walls (wood metal concrete) with or without

external insulation

Always keep a minimum 2cm air gap for ventilation behind the cladding (check the

recommendations of the local regulations )

The supporting structure has to be placed perpendicular to the cladding For vertical installation

the ventilation will be enabled through the claddingrsquos ribs or thanks to a crossed structure (following

the local recommendations)

Wide board With 300 mm width

KEY INSTALLATION PRINCIPLES

Mitre cut with perfectly aligned grooving

Horizontal or vertical fitting with various layouts

Invisible fixing using steel hooks screwed into the wood or metal supporting structures

Fast fixing using screwed steel hooks

NEOLIFEreg COVER claddingcan be fitted using all the conventional facade and covering accessories

Vertical fitting with a corner profile

6mm open expansion gapat the end of the board

Horizontal fittingwith a mitre cut

or with a corner profile

Metal CopingWindow revealwith metal profile

Outside corner or window reveal with Neolife corner profile

KEY INSTALLATION PRINCIPLES

DESIGN GUIDELINES

When the sign is installed onto the claddingwith no water runoff possibility It will cause stains on the claddingwhen drying (due to the mix of dust andpollution)

Flat metall elements without watertightnessmanagement Dirty water runoff causes stains

Advice

Leave space between cladding and the signand fix it on the load-bearing wall

INSTALLATION OF SHOP SIGN

OTHERS

Sign stuck onto the wall Sign away from the wall

Advice Install the element before the cladding bymanaging the waterlightness against the wallPlan a 10 slope and a waterdrop in order toavoid a water runoff onto the cladding

infiltration Seal and fixing

Cutting for expansion

Flat Casquette

Fixing againstthe wall

Absence of water drop Water drop

DESIGN GUIDELINES

BEST PRACTICEFind all the best practices in the NEOLIFEreg installation guide

available on our website wwwneolife-solutionscom

Closed metal profile at the junction betweencladding render no water runoffpossibility risk of stains and moisture on thestructure no ventilation

Flat window sill without water drop Dust and pollution collects on the windowsill and causes stains onto the cladding afterraining

WINDOW SILL

Advice Make a window sill with a 10 slopeminimum and a water drop with 30 mm gapfrom the cladding

Flat metal window sill

30mm

Advice Use a perforated metal ending profile and raise the cladding boards 5mm above the profile

no ventilation

Visible screwWater storage

Hidden screw

Perforated closure profile ventilation and water runoff

5mm

ENDINGS JUNCTIONS

Absence of water drop Water drop

REMARQUES IMPORTANTES SUR LA POSECAUTION

THE FULL INSTALLATION MANUAL OF COVER CLADDING PANELS IS AVAILABLE AT

wwwneolife-solutionscom

NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters

disposal for any clarifications concerning the installation procedure of its products

The specifications and recommendations given in the installation guide are not a

substitute to regulations concerning safety environment and professional regulatory

dispositions

All instructions concerning the installation of our cladding are to be followed

Assembly errors are not covered by the NEOLIFEreg guarantee

An approved fitter shall be able to assess the construction conformity to the local

professional installation guidelines

MAINTENANCE

21

Depending on the boards dirt after implementation (presence of mud dust etchellip) especially in the

grooves rain stains can appear on the surface

NEOLIFE strongly recommend to clean the boards after implementation with a pressure

washer following the boardsrsquo orientation (distance of min 20cm from the board DO NOT

USE a rotary nozzle)

Recommendations

Do not forget to clean the window shelves as well avoiding so any risk of dust stains on the

cladding after the first rain (windows are frequently dusty during construction)

All metal joineries (windows parapet capping etchellip) have to have a drip-edge flashing in

order to limit the water runoff on the cladding Shop signs or any other elements installed on

the cladding have to be moved forward (space left between cladding and the element) to

avoid any stains

Caution

If any operation involving the use of asphalt or concrete occurs after facade completion

NEOLIFE recommend to protect the cladding with a plastic cover in order to avoid stains

Indeed if not protected a greasy steam can spread on the surface and in the grooves In that

case a grease-removing product will be needed to clean the boards and all the surrounding

elements

BUILDING SITE CLEANING

LONG LASTING

VERY LIMITED MAINTENANCE

The material does not require any wood preservative (oils varnishes saturators hellip)

bull The VESTAreg material is naturally equivalent to use class 4(service environment In contact with ground or fresh water amp Permanently exposed to wetting The use classes rank the risk of exposure to decay and insect attack for differing in service environments according to EN 335 ndash 2)

bull Highly hydrophobic and rot-proof no algae fungi or moss development

bull Insect-resistant does not require any treatments against termites

STAIN REMOVAL

STAINS

Tanin stains

During the first weeks after installation tannin rings may occur because of the rain especially

on claddings with a light colour They will be washed off and fade during the next rain to

lessen until they completely disappear Be careful not to mistake these stains with dust or

pollution stains which appear on all cladding types

Bleach-based cleaning products

Slight discolouration Clean with water and complete if needed with slight brushing in the

boards orientation

Graffities oil paint and ink

Use a specialised stain remover (ex laquo STG 105 BIO raquo de STG)

Bitumen grease

Use a specialised stain remover (ex laquo Scalp Aqua 03 raquo)

Oxidation stains after contact with a corroded metal

Use a specialised wood de-greyer (ex laquo Scalp Neutral DA 66 raquo)

Caution

- Analyse properly the substance to clean so to use the right stain removing product

- Always test the stain removing product on a small and discrete surface before cleaning the

entire board

- It is mandatory that you analyse on a long time scale (and after exposure to Uvs) that the

solution you choose will not react with the cladding and therefore produce unsightly effects

DAMAGES

bull Scratches cigarette marks abrasion Brush away with a brass brush (lengthways)

TECHNICAL CHARACTERISTICS

25

SYSTEM PERFORMANCES

DESIGNATIONTEST

METHODS amp STANDARDS

CLADDING OUTLIFE COVER 6 amp 14

WIND LOAD (Depression) COVER 6 (4 ribs) COVER 14 (2 ribss)

Fixings description Eurocodes EN 1991-1-4 Test results Maximum shearing

pressure Test results Maximum shearingpressure

Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction

4 900 Pa

(degradation)140 kNm2 5 200 Pa

(degradation) 148 kNm2

Maximum 400mm centre-to-centre support spacing with one fixing tab at every junction 8 300 Pa (ruine) 237 kNm2 8 300 Pa (ruine) 237 kNm2

IMPACT RESISTANCE COVER 6 (4 ribs) COVER 14 (2 ribs)

Fixings description NF P 08302 Test results Test results

Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction

No damage with the impact energies below

Soft impacts 50Kg 130J

Soft impacts 3Kg 20J

Hard impacts 1Kg 3J

No damage with the impact energies below Soft impacts 50Kg 130J

Soft impacts 3Kg 20JHard impacts 1Kg 3J

SEISMIC RESISTANCE COVER 6 amp14

COVER 6 amp 14can be installed in seismic zones and buildings according to the following details

Highest seismic behaviour following Eurocode 8 no risk of falling boards or permanent deformations after static and dynamic test

FIRE RESISTANCE COVER 6 COVER 14

Tests description EN 13823 et EN 13501-12007

Fire rating

(on A2-s1d0 wall)

Fire rating

(on A2-s1d0 wall)

SBI test carried out on 3 models forming a 1500mm high 1000mm long and 500mm wide

dihedral wedge Assembly on air board and horizontal wood batten Valable contre un

substrat A2-s1d0

B-s3d0

Equivalent UK class 0

FIGRA average 1151Ws

THR average 6MJ

SMOGRA average 371 m2s2

B-s3d0

Equivalent UK class 0

FIGRA average 1924Ws

THR average 112MJ

SMOGRA average 592m2s2

Horizontal installation Class B-s3 d0 - Vertical installation on metal framework Class B s3 d0 on wooden framework Class C s3 d0 (EN 13501-12007)

PHYSICAL AND MECHANICAL FEATURES

DESIGNATION TEST METHODES amp STANDARDS COVER 6 amp 14 OUTLIFE CLADDING

FLAMMABLE MASS COVER 6 COVER 14Tests description NF EN 13238 Flammable mass per sqm (MJ)Tests realised according to the crucible method on at least 5 product samples 334 MJ 285 MJ

APPEARANCE DURABILITY(ageing under QUV) COVER 6 amp 14

Test descriptionNF EN 927-6 (2006)

FCBA‐ LBO6-PHY‐001

Test results

Artificial ageing test under QUV allowing an assessment of durability and decorative

properties modification Total duration 10 weeks comprising

condensation UV radiation and water spray phases

Stable products according to the EN 927-2

No blistering defects are observed according to ISO 4628-2 standard Resultt 0No cracking defects are observed according to ISO 4628-4 standard Result 0No flaking defects are observed according to ISO 4628-5 standard Result 0

THERMAL EXPANSION COVER 6 amp 14

Test description

ISO 11359-2 adapted to

FCBA - LBO6PHY-001

Test results

Thermodilatometric test in climatic room going from -20deg to +60deg to determine the profils

thermal expansion coefficient in solid state

Coefficient de dilatation thermique moyen

Longitudinally δL = 380 degK-1 10-6 standard spacing 210 degK-1 10-6 For uninstalled boardsTransversally δB = 575 degK-1 10-6 standard spacing 211 degK-1 10-6 For uninstalled boards

WATER UPTAKE DETERMINATION COVER 6 amp 14

Test description FCBA‐LBO‐MECA‐014 Test results

Water uptake determination after immersion in cold water during 28 days Measure of the

mass in its initial state and after 124714 et 28 days

Boards suitable to use in class 4 (Wood use class NF EN 335-2)Boards naturally resistant against fungus and soft rotAverage water uptake after 28 days 803Water content at 28 days and imputed to the cellulosic matter 143

ELASTICITY CONSTRAINS AND MODULE IN FLEXION COVER 6 amp 14

Test description

FCBA‐LBO‐MECA‐008

NF EN 310 modifiedWPC profiles

Test results

3 point flexion under normal conditions 20degCand 65 RH

Eaverage = 904 Nmm2fm = 40 Nmm2

ENVIRONMENTAL CHARACTERISTICS

28

VESTAreg ECO-MATERIAL

VESTAreg (Vegetal Ecological Stable Timber

Advantage) is an innovative and eco-friendly compound

with exceptional properties It was developed by

NEOCOreg NEOLIFEreglsquos Research Centre specialising in

green technologies in partnership with European experts

EXCEPTIONAL WOOD FIBER CONTENTVESTAreg revolutionises eco-materials and the design of

environmental solutions for construction projects and the

landscaping of outside spaces It finally brings a response

to the architects landscapers and design officesrsquo

demands working on eco-construction and sustainable

development projects

ECO-FRIENDLYThe wood fibres contained in VESTAreg come exclusively

from sawmills offcuts the wood coming from sustainably

managed European forests The production of our material

does not require the cutting of any trees and does not use treated wood from recycled pallets Moreover

NEOLIFE does not use any toxic additives in the production process of the material

VESTAreg is 100 recyclable with a perfect traceability it only contains virgin substances (no recycled

components for which establishing a traceability is impossible)

CLEANDoes not contain solvents adhesives or phthalates and does not generate

toxic emissions

STABLE AND RESISTANTVESTAreg fibres benefit from a thermal treatment which provides hydrophobic properties to the material The

formula reinforced with mineral resin lignin and antioxidants enables a remarkable mechanical resistance as

well as an outstanding design

The mineral pigments also offer a strong resistance to UV rays making the colours more durable whatever the

exposure

SOURCE

Raw material VESTAreg

X-FIRE is highly fire-resistant Wood fibres coming from sustainably managed European forests

Board Production France

COMPOSITIONby Volume 75 wood fibres mineral oil mineral salts mineral pigments

PHYSICAL PROPERTIES

Mass sqm COVER 6 195 kgmsup2 COVER 14 165 kgmsup2

Density 1500 kgm3

Parasite resistance Equivalent to use class 4 No development of fungal rot mosses or mould Insect-resistant including termites

Surface appearance Micro-striated surface splinter free blisters or flakes off Maintenance-free

Scratches resistance Equivalent to natural wood - Brushing possible without discolouration

Thermal inertia Low thermal inertia due to the high wood fibres content

ENVIRONMENTAL PROPERTIES

Recycling 100 recyclable 75 renewable and combustible (75 biomass)

Toxic substances Contains no toxic or dangerous products (according to Reach Regulation EC19072006)

Chemical fire retardant substance None

Solvents None

Heavy metals None lead-and mercury-free stabilization

Phthalates adhesives None

Formaldehydes and VOCs Lower than or equal to natural wood

VESTAreg REINFORCED WOOD FIBER

VESTA X-FIRE

ENVIRONMENTAL PRODUCT DECLARATION

1 - Values describing the environmental impacts

Owner of the declaration NEOLIFE Editor BUREAU VERITAS CODDE Declaration reference DEP_NEOLIFE_COVER_201507

Publication 10072015 Validity 10072020

Complies with the standard ISO 14025 NF EN 15804+A1 And itrsquos national addendum X P01-064CN

Environmental Declaration of the COVER productavailable on request

ENVIRONMENTAL PRODUCT DECLARATION

2 ndash Values describing the use of primary energetic sources other resources and water

3 ndash Complementary values describing the outflows

FURTHER DETAILS

33

TECHNICAL DESCRIPTION

French accreditaion type laquo Avis Technique Expeacuterimental de Type A raquo issued by CSTB (France)

Ndeg2278 ndash Available at httpevaluationcstbfrrechercherproduits-evaluesprestations=atex

VESTA Reinforced Wood Fiber cladding containing at least 75 wood fibres

Boards with a slatted aspect featuring 6 cm or 14 cm ribs

Fire rating with natural mineral salts following EN 13501-12007

COVER 6 B-s3-d0 minimum

COVER 14 B-s3-d0 minimum

Invisible fixing with stainless steel hooks screwed into wood or metal battens

Fast and accurate fitting thanks to the interlocking board system

Outside corners catered for by using 45deg miter cuts or aluminium corner profile

Dimensional stability of maximum 2mm m over ∆80degC

rot-proof not sensitive to moss and mould

Insect-resistant termites included

Stable colors after natural patina is acquired

Contact us to get the full technical specification sheet

CONTACT

CAUTION

This technical sheet is associated with the technical installation guide of CLAD claddingboard available at wwwneolife-solutionscom

NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters

disposal for any clarifications concerning the installation procedure of its products

The specifications and recommendations given in the installation guide are not a

substitute to regulations concerning safety environment and professional regulatory

dispositions

All instructions concerning the installation of our cladding are to be followed

Assembly errors are not covered by the NEOLIFEreg guarantee

An approved fitter shall be able to assess the construction conformity to the local

professional installation guidelines

304 Route Nationale 6 ndash Celtic Parc Bacirctiment Avalon II - 69760 Limonest FranceTel +33 (0)4 78 25 63 08 ndash Fax +33 (0)4 72 29 29 47

wwwneolife-solutionscom

Page 11: COVER 6 & 14 CLADDING · 2020. 11. 3. · 60 cm centre-to-centre spacing 10 / m ... sill and causes stains onto the cladding after raining WINDOW SILL Advice : Make a window sill

IMPLEMENTATION ON EXTERNAL THERMAL INSULATION

Horizontal fitting

Vertical fitting

TIMBER FRAME OR MASONRY (CONCRETE BRICKhellip) WALL WITH WOOD OR METAL BATTENS

Timber frame wall

Concrete wall

Timber frame wall

Concrete wall

Insulation

Insulation

IMPORTANT

Ensure the cladding is installedon ventilated battens minimumcross-section of wooden battens27x40 mm

Centre-to-centre spacing of 400to 600 mm depending on theimplementation area requiredlayout wind force or buildingheight

This batten framework can befixed on each wall type (woodmetal concrete etc) with orwithout exterior insulation

In all cases a minimum air gap of2 cm is required behind thecladding (check local regulations)

IMPLEMENTATION ON LINER TRAYS (INDUSTRIAL BUILDING ENVELLOPE)

Horinzontal fitting

IMPORTANT

Ensure the cladding is installed onventilated battens minimum cross-section of metal battens 20 x 40 mm

Centre-to-centre spacing of 400 to600 mm depending on theimplementation area required layout wind force or building height

This batten framework can be fixedon each wall type (wood metalconcrete etc) with or without exteriorinsulation

In all cases a minimum air gap of 2cm is required behind the cladding(check local regulations)

Steelstructure

Liner trays

Vertical fitting

Insulation

Insulation

Steelstructure

Liner trays

REMARQUES IMPORTANTES SUR LA POSE

BOARD PREPARATION Length 325 cm (tolerance of +0 20 mm)

Width 320 mm visible width when installed = 300mm (tolerance of plusmn 255 mm)

Thickness 285 mm (tolerance of plusmn 115 mm)

Squaring has to be done on site

Boards have to be calibrated according to layout

START Vertical installation Start with a metal or Aluminium profile It is highly recommended to install all the

boards in the same orientation in order to obtain a uniform colour Indeed the random brushing

creates an effect on the surface that capture the lights differently according the boards orientation

Pose horizontale Boards have to be installed with the groove at the bottom and the tongue at the top

IMPORTANT NOTICES

All instructions concerning the installation of our cladding are to be followed

Assembly errors are not covered by the NEOLIFEreg guarantee

An approved fitter shall be able to assess the construction conformity to the local

professional installation guidelines

Groove at the bottom

Horizontal intallation

Tongue at the top

Verticalinstallation

Profil alu de deacutepart visseacute

Screwed aluminium starting profile

REMARQUES IMPORTANTES SUR LA POSE

ALWAYS KEEP A 6 MM EXPANSION JOINT

A minimum space of 6mm between the 325m boards

and contiguous elements (joinery wall other cladding

boards) should be left to enable the natural expansion

of the NEOLIFEreg cladding boards

Always maintain 15 mm expansion per linear meter

(or 2mm in case of high temperature variations)

IMPORTANT NOTICES

NOT FOR STRUCTURAL USE Under no circumstances should the cladding boards be used for load-bearing or structural purposes

The professional rules and recommendations governing the cladding installation must be followed

NO SEALING PROPERTIES The boards are not designed to ensure the watertightness of the external facade

They should be used with a rainscreen wherever itrsquos required which will provide the weatherproofing

element in compliance with the local Building Regulations

FIXING ADDITIONAL ITEMS TO THE FACADE The cladding is not load-bearing

Anything fixed to the facade must be attached to the supporting structure behind the cladding

6mm

CAUTIONThe specifications and recommendations given in the NEOLIFEreg installation guide available at

wwwneolife-solutionscom website are not a substitute to regulations concerning safety

environment and regulatory installation specifications

REMARQUES IMPORTANTES SUR LA POSEIMPORTANT NOTICES

The panels have always to be fixed on each end at less than 1 cm of the boardrsquos edge

both in horizontal and vertical installations

EPDM strip

Concrete wall

1 Batten min size 60mmOr 2 battens min size 27x40mm

6 mm expansion joint

PREPARATION OF THE STRUCTURE

CAUTION

Make sure to respect the cladding installation steps recommended by the local professional guidelines

IMPORTANT ADVICES

The supporting structure (wood or metal) has to be perfectly flat to get a perfect facade The installation has to be planned on a ventilated wood structure with a minimum batten size of

27x40mm or on omega metal profiles 30x30x30 with a 400 ou 600 mm centre to centre distance

following the buildingrsquos category and height

The supporting structure can be fitted on every kind of walls (wood metal concrete) with or without

external insulation

Always keep a minimum 2cm air gap for ventilation behind the cladding (check the

recommendations of the local regulations )

The supporting structure has to be placed perpendicular to the cladding For vertical installation

the ventilation will be enabled through the claddingrsquos ribs or thanks to a crossed structure (following

the local recommendations)

Wide board With 300 mm width

KEY INSTALLATION PRINCIPLES

Mitre cut with perfectly aligned grooving

Horizontal or vertical fitting with various layouts

Invisible fixing using steel hooks screwed into the wood or metal supporting structures

Fast fixing using screwed steel hooks

NEOLIFEreg COVER claddingcan be fitted using all the conventional facade and covering accessories

Vertical fitting with a corner profile

6mm open expansion gapat the end of the board

Horizontal fittingwith a mitre cut

or with a corner profile

Metal CopingWindow revealwith metal profile

Outside corner or window reveal with Neolife corner profile

KEY INSTALLATION PRINCIPLES

DESIGN GUIDELINES

When the sign is installed onto the claddingwith no water runoff possibility It will cause stains on the claddingwhen drying (due to the mix of dust andpollution)

Flat metall elements without watertightnessmanagement Dirty water runoff causes stains

Advice

Leave space between cladding and the signand fix it on the load-bearing wall

INSTALLATION OF SHOP SIGN

OTHERS

Sign stuck onto the wall Sign away from the wall

Advice Install the element before the cladding bymanaging the waterlightness against the wallPlan a 10 slope and a waterdrop in order toavoid a water runoff onto the cladding

infiltration Seal and fixing

Cutting for expansion

Flat Casquette

Fixing againstthe wall

Absence of water drop Water drop

DESIGN GUIDELINES

BEST PRACTICEFind all the best practices in the NEOLIFEreg installation guide

available on our website wwwneolife-solutionscom

Closed metal profile at the junction betweencladding render no water runoffpossibility risk of stains and moisture on thestructure no ventilation

Flat window sill without water drop Dust and pollution collects on the windowsill and causes stains onto the cladding afterraining

WINDOW SILL

Advice Make a window sill with a 10 slopeminimum and a water drop with 30 mm gapfrom the cladding

Flat metal window sill

30mm

Advice Use a perforated metal ending profile and raise the cladding boards 5mm above the profile

no ventilation

Visible screwWater storage

Hidden screw

Perforated closure profile ventilation and water runoff

5mm

ENDINGS JUNCTIONS

Absence of water drop Water drop

REMARQUES IMPORTANTES SUR LA POSECAUTION

THE FULL INSTALLATION MANUAL OF COVER CLADDING PANELS IS AVAILABLE AT

wwwneolife-solutionscom

NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters

disposal for any clarifications concerning the installation procedure of its products

The specifications and recommendations given in the installation guide are not a

substitute to regulations concerning safety environment and professional regulatory

dispositions

All instructions concerning the installation of our cladding are to be followed

Assembly errors are not covered by the NEOLIFEreg guarantee

An approved fitter shall be able to assess the construction conformity to the local

professional installation guidelines

MAINTENANCE

21

Depending on the boards dirt after implementation (presence of mud dust etchellip) especially in the

grooves rain stains can appear on the surface

NEOLIFE strongly recommend to clean the boards after implementation with a pressure

washer following the boardsrsquo orientation (distance of min 20cm from the board DO NOT

USE a rotary nozzle)

Recommendations

Do not forget to clean the window shelves as well avoiding so any risk of dust stains on the

cladding after the first rain (windows are frequently dusty during construction)

All metal joineries (windows parapet capping etchellip) have to have a drip-edge flashing in

order to limit the water runoff on the cladding Shop signs or any other elements installed on

the cladding have to be moved forward (space left between cladding and the element) to

avoid any stains

Caution

If any operation involving the use of asphalt or concrete occurs after facade completion

NEOLIFE recommend to protect the cladding with a plastic cover in order to avoid stains

Indeed if not protected a greasy steam can spread on the surface and in the grooves In that

case a grease-removing product will be needed to clean the boards and all the surrounding

elements

BUILDING SITE CLEANING

LONG LASTING

VERY LIMITED MAINTENANCE

The material does not require any wood preservative (oils varnishes saturators hellip)

bull The VESTAreg material is naturally equivalent to use class 4(service environment In contact with ground or fresh water amp Permanently exposed to wetting The use classes rank the risk of exposure to decay and insect attack for differing in service environments according to EN 335 ndash 2)

bull Highly hydrophobic and rot-proof no algae fungi or moss development

bull Insect-resistant does not require any treatments against termites

STAIN REMOVAL

STAINS

Tanin stains

During the first weeks after installation tannin rings may occur because of the rain especially

on claddings with a light colour They will be washed off and fade during the next rain to

lessen until they completely disappear Be careful not to mistake these stains with dust or

pollution stains which appear on all cladding types

Bleach-based cleaning products

Slight discolouration Clean with water and complete if needed with slight brushing in the

boards orientation

Graffities oil paint and ink

Use a specialised stain remover (ex laquo STG 105 BIO raquo de STG)

Bitumen grease

Use a specialised stain remover (ex laquo Scalp Aqua 03 raquo)

Oxidation stains after contact with a corroded metal

Use a specialised wood de-greyer (ex laquo Scalp Neutral DA 66 raquo)

Caution

- Analyse properly the substance to clean so to use the right stain removing product

- Always test the stain removing product on a small and discrete surface before cleaning the

entire board

- It is mandatory that you analyse on a long time scale (and after exposure to Uvs) that the

solution you choose will not react with the cladding and therefore produce unsightly effects

DAMAGES

bull Scratches cigarette marks abrasion Brush away with a brass brush (lengthways)

TECHNICAL CHARACTERISTICS

25

SYSTEM PERFORMANCES

DESIGNATIONTEST

METHODS amp STANDARDS

CLADDING OUTLIFE COVER 6 amp 14

WIND LOAD (Depression) COVER 6 (4 ribs) COVER 14 (2 ribss)

Fixings description Eurocodes EN 1991-1-4 Test results Maximum shearing

pressure Test results Maximum shearingpressure

Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction

4 900 Pa

(degradation)140 kNm2 5 200 Pa

(degradation) 148 kNm2

Maximum 400mm centre-to-centre support spacing with one fixing tab at every junction 8 300 Pa (ruine) 237 kNm2 8 300 Pa (ruine) 237 kNm2

IMPACT RESISTANCE COVER 6 (4 ribs) COVER 14 (2 ribs)

Fixings description NF P 08302 Test results Test results

Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction

No damage with the impact energies below

Soft impacts 50Kg 130J

Soft impacts 3Kg 20J

Hard impacts 1Kg 3J

No damage with the impact energies below Soft impacts 50Kg 130J

Soft impacts 3Kg 20JHard impacts 1Kg 3J

SEISMIC RESISTANCE COVER 6 amp14

COVER 6 amp 14can be installed in seismic zones and buildings according to the following details

Highest seismic behaviour following Eurocode 8 no risk of falling boards or permanent deformations after static and dynamic test

FIRE RESISTANCE COVER 6 COVER 14

Tests description EN 13823 et EN 13501-12007

Fire rating

(on A2-s1d0 wall)

Fire rating

(on A2-s1d0 wall)

SBI test carried out on 3 models forming a 1500mm high 1000mm long and 500mm wide

dihedral wedge Assembly on air board and horizontal wood batten Valable contre un

substrat A2-s1d0

B-s3d0

Equivalent UK class 0

FIGRA average 1151Ws

THR average 6MJ

SMOGRA average 371 m2s2

B-s3d0

Equivalent UK class 0

FIGRA average 1924Ws

THR average 112MJ

SMOGRA average 592m2s2

Horizontal installation Class B-s3 d0 - Vertical installation on metal framework Class B s3 d0 on wooden framework Class C s3 d0 (EN 13501-12007)

PHYSICAL AND MECHANICAL FEATURES

DESIGNATION TEST METHODES amp STANDARDS COVER 6 amp 14 OUTLIFE CLADDING

FLAMMABLE MASS COVER 6 COVER 14Tests description NF EN 13238 Flammable mass per sqm (MJ)Tests realised according to the crucible method on at least 5 product samples 334 MJ 285 MJ

APPEARANCE DURABILITY(ageing under QUV) COVER 6 amp 14

Test descriptionNF EN 927-6 (2006)

FCBA‐ LBO6-PHY‐001

Test results

Artificial ageing test under QUV allowing an assessment of durability and decorative

properties modification Total duration 10 weeks comprising

condensation UV radiation and water spray phases

Stable products according to the EN 927-2

No blistering defects are observed according to ISO 4628-2 standard Resultt 0No cracking defects are observed according to ISO 4628-4 standard Result 0No flaking defects are observed according to ISO 4628-5 standard Result 0

THERMAL EXPANSION COVER 6 amp 14

Test description

ISO 11359-2 adapted to

FCBA - LBO6PHY-001

Test results

Thermodilatometric test in climatic room going from -20deg to +60deg to determine the profils

thermal expansion coefficient in solid state

Coefficient de dilatation thermique moyen

Longitudinally δL = 380 degK-1 10-6 standard spacing 210 degK-1 10-6 For uninstalled boardsTransversally δB = 575 degK-1 10-6 standard spacing 211 degK-1 10-6 For uninstalled boards

WATER UPTAKE DETERMINATION COVER 6 amp 14

Test description FCBA‐LBO‐MECA‐014 Test results

Water uptake determination after immersion in cold water during 28 days Measure of the

mass in its initial state and after 124714 et 28 days

Boards suitable to use in class 4 (Wood use class NF EN 335-2)Boards naturally resistant against fungus and soft rotAverage water uptake after 28 days 803Water content at 28 days and imputed to the cellulosic matter 143

ELASTICITY CONSTRAINS AND MODULE IN FLEXION COVER 6 amp 14

Test description

FCBA‐LBO‐MECA‐008

NF EN 310 modifiedWPC profiles

Test results

3 point flexion under normal conditions 20degCand 65 RH

Eaverage = 904 Nmm2fm = 40 Nmm2

ENVIRONMENTAL CHARACTERISTICS

28

VESTAreg ECO-MATERIAL

VESTAreg (Vegetal Ecological Stable Timber

Advantage) is an innovative and eco-friendly compound

with exceptional properties It was developed by

NEOCOreg NEOLIFEreglsquos Research Centre specialising in

green technologies in partnership with European experts

EXCEPTIONAL WOOD FIBER CONTENTVESTAreg revolutionises eco-materials and the design of

environmental solutions for construction projects and the

landscaping of outside spaces It finally brings a response

to the architects landscapers and design officesrsquo

demands working on eco-construction and sustainable

development projects

ECO-FRIENDLYThe wood fibres contained in VESTAreg come exclusively

from sawmills offcuts the wood coming from sustainably

managed European forests The production of our material

does not require the cutting of any trees and does not use treated wood from recycled pallets Moreover

NEOLIFE does not use any toxic additives in the production process of the material

VESTAreg is 100 recyclable with a perfect traceability it only contains virgin substances (no recycled

components for which establishing a traceability is impossible)

CLEANDoes not contain solvents adhesives or phthalates and does not generate

toxic emissions

STABLE AND RESISTANTVESTAreg fibres benefit from a thermal treatment which provides hydrophobic properties to the material The

formula reinforced with mineral resin lignin and antioxidants enables a remarkable mechanical resistance as

well as an outstanding design

The mineral pigments also offer a strong resistance to UV rays making the colours more durable whatever the

exposure

SOURCE

Raw material VESTAreg

X-FIRE is highly fire-resistant Wood fibres coming from sustainably managed European forests

Board Production France

COMPOSITIONby Volume 75 wood fibres mineral oil mineral salts mineral pigments

PHYSICAL PROPERTIES

Mass sqm COVER 6 195 kgmsup2 COVER 14 165 kgmsup2

Density 1500 kgm3

Parasite resistance Equivalent to use class 4 No development of fungal rot mosses or mould Insect-resistant including termites

Surface appearance Micro-striated surface splinter free blisters or flakes off Maintenance-free

Scratches resistance Equivalent to natural wood - Brushing possible without discolouration

Thermal inertia Low thermal inertia due to the high wood fibres content

ENVIRONMENTAL PROPERTIES

Recycling 100 recyclable 75 renewable and combustible (75 biomass)

Toxic substances Contains no toxic or dangerous products (according to Reach Regulation EC19072006)

Chemical fire retardant substance None

Solvents None

Heavy metals None lead-and mercury-free stabilization

Phthalates adhesives None

Formaldehydes and VOCs Lower than or equal to natural wood

VESTAreg REINFORCED WOOD FIBER

VESTA X-FIRE

ENVIRONMENTAL PRODUCT DECLARATION

1 - Values describing the environmental impacts

Owner of the declaration NEOLIFE Editor BUREAU VERITAS CODDE Declaration reference DEP_NEOLIFE_COVER_201507

Publication 10072015 Validity 10072020

Complies with the standard ISO 14025 NF EN 15804+A1 And itrsquos national addendum X P01-064CN

Environmental Declaration of the COVER productavailable on request

ENVIRONMENTAL PRODUCT DECLARATION

2 ndash Values describing the use of primary energetic sources other resources and water

3 ndash Complementary values describing the outflows

FURTHER DETAILS

33

TECHNICAL DESCRIPTION

French accreditaion type laquo Avis Technique Expeacuterimental de Type A raquo issued by CSTB (France)

Ndeg2278 ndash Available at httpevaluationcstbfrrechercherproduits-evaluesprestations=atex

VESTA Reinforced Wood Fiber cladding containing at least 75 wood fibres

Boards with a slatted aspect featuring 6 cm or 14 cm ribs

Fire rating with natural mineral salts following EN 13501-12007

COVER 6 B-s3-d0 minimum

COVER 14 B-s3-d0 minimum

Invisible fixing with stainless steel hooks screwed into wood or metal battens

Fast and accurate fitting thanks to the interlocking board system

Outside corners catered for by using 45deg miter cuts or aluminium corner profile

Dimensional stability of maximum 2mm m over ∆80degC

rot-proof not sensitive to moss and mould

Insect-resistant termites included

Stable colors after natural patina is acquired

Contact us to get the full technical specification sheet

CONTACT

CAUTION

This technical sheet is associated with the technical installation guide of CLAD claddingboard available at wwwneolife-solutionscom

NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters

disposal for any clarifications concerning the installation procedure of its products

The specifications and recommendations given in the installation guide are not a

substitute to regulations concerning safety environment and professional regulatory

dispositions

All instructions concerning the installation of our cladding are to be followed

Assembly errors are not covered by the NEOLIFEreg guarantee

An approved fitter shall be able to assess the construction conformity to the local

professional installation guidelines

304 Route Nationale 6 ndash Celtic Parc Bacirctiment Avalon II - 69760 Limonest FranceTel +33 (0)4 78 25 63 08 ndash Fax +33 (0)4 72 29 29 47

wwwneolife-solutionscom

Page 12: COVER 6 & 14 CLADDING · 2020. 11. 3. · 60 cm centre-to-centre spacing 10 / m ... sill and causes stains onto the cladding after raining WINDOW SILL Advice : Make a window sill

IMPLEMENTATION ON LINER TRAYS (INDUSTRIAL BUILDING ENVELLOPE)

Horinzontal fitting

IMPORTANT

Ensure the cladding is installed onventilated battens minimum cross-section of metal battens 20 x 40 mm

Centre-to-centre spacing of 400 to600 mm depending on theimplementation area required layout wind force or building height

This batten framework can be fixedon each wall type (wood metalconcrete etc) with or without exteriorinsulation

In all cases a minimum air gap of 2cm is required behind the cladding(check local regulations)

Steelstructure

Liner trays

Vertical fitting

Insulation

Insulation

Steelstructure

Liner trays

REMARQUES IMPORTANTES SUR LA POSE

BOARD PREPARATION Length 325 cm (tolerance of +0 20 mm)

Width 320 mm visible width when installed = 300mm (tolerance of plusmn 255 mm)

Thickness 285 mm (tolerance of plusmn 115 mm)

Squaring has to be done on site

Boards have to be calibrated according to layout

START Vertical installation Start with a metal or Aluminium profile It is highly recommended to install all the

boards in the same orientation in order to obtain a uniform colour Indeed the random brushing

creates an effect on the surface that capture the lights differently according the boards orientation

Pose horizontale Boards have to be installed with the groove at the bottom and the tongue at the top

IMPORTANT NOTICES

All instructions concerning the installation of our cladding are to be followed

Assembly errors are not covered by the NEOLIFEreg guarantee

An approved fitter shall be able to assess the construction conformity to the local

professional installation guidelines

Groove at the bottom

Horizontal intallation

Tongue at the top

Verticalinstallation

Profil alu de deacutepart visseacute

Screwed aluminium starting profile

REMARQUES IMPORTANTES SUR LA POSE

ALWAYS KEEP A 6 MM EXPANSION JOINT

A minimum space of 6mm between the 325m boards

and contiguous elements (joinery wall other cladding

boards) should be left to enable the natural expansion

of the NEOLIFEreg cladding boards

Always maintain 15 mm expansion per linear meter

(or 2mm in case of high temperature variations)

IMPORTANT NOTICES

NOT FOR STRUCTURAL USE Under no circumstances should the cladding boards be used for load-bearing or structural purposes

The professional rules and recommendations governing the cladding installation must be followed

NO SEALING PROPERTIES The boards are not designed to ensure the watertightness of the external facade

They should be used with a rainscreen wherever itrsquos required which will provide the weatherproofing

element in compliance with the local Building Regulations

FIXING ADDITIONAL ITEMS TO THE FACADE The cladding is not load-bearing

Anything fixed to the facade must be attached to the supporting structure behind the cladding

6mm

CAUTIONThe specifications and recommendations given in the NEOLIFEreg installation guide available at

wwwneolife-solutionscom website are not a substitute to regulations concerning safety

environment and regulatory installation specifications

REMARQUES IMPORTANTES SUR LA POSEIMPORTANT NOTICES

The panels have always to be fixed on each end at less than 1 cm of the boardrsquos edge

both in horizontal and vertical installations

EPDM strip

Concrete wall

1 Batten min size 60mmOr 2 battens min size 27x40mm

6 mm expansion joint

PREPARATION OF THE STRUCTURE

CAUTION

Make sure to respect the cladding installation steps recommended by the local professional guidelines

IMPORTANT ADVICES

The supporting structure (wood or metal) has to be perfectly flat to get a perfect facade The installation has to be planned on a ventilated wood structure with a minimum batten size of

27x40mm or on omega metal profiles 30x30x30 with a 400 ou 600 mm centre to centre distance

following the buildingrsquos category and height

The supporting structure can be fitted on every kind of walls (wood metal concrete) with or without

external insulation

Always keep a minimum 2cm air gap for ventilation behind the cladding (check the

recommendations of the local regulations )

The supporting structure has to be placed perpendicular to the cladding For vertical installation

the ventilation will be enabled through the claddingrsquos ribs or thanks to a crossed structure (following

the local recommendations)

Wide board With 300 mm width

KEY INSTALLATION PRINCIPLES

Mitre cut with perfectly aligned grooving

Horizontal or vertical fitting with various layouts

Invisible fixing using steel hooks screwed into the wood or metal supporting structures

Fast fixing using screwed steel hooks

NEOLIFEreg COVER claddingcan be fitted using all the conventional facade and covering accessories

Vertical fitting with a corner profile

6mm open expansion gapat the end of the board

Horizontal fittingwith a mitre cut

or with a corner profile

Metal CopingWindow revealwith metal profile

Outside corner or window reveal with Neolife corner profile

KEY INSTALLATION PRINCIPLES

DESIGN GUIDELINES

When the sign is installed onto the claddingwith no water runoff possibility It will cause stains on the claddingwhen drying (due to the mix of dust andpollution)

Flat metall elements without watertightnessmanagement Dirty water runoff causes stains

Advice

Leave space between cladding and the signand fix it on the load-bearing wall

INSTALLATION OF SHOP SIGN

OTHERS

Sign stuck onto the wall Sign away from the wall

Advice Install the element before the cladding bymanaging the waterlightness against the wallPlan a 10 slope and a waterdrop in order toavoid a water runoff onto the cladding

infiltration Seal and fixing

Cutting for expansion

Flat Casquette

Fixing againstthe wall

Absence of water drop Water drop

DESIGN GUIDELINES

BEST PRACTICEFind all the best practices in the NEOLIFEreg installation guide

available on our website wwwneolife-solutionscom

Closed metal profile at the junction betweencladding render no water runoffpossibility risk of stains and moisture on thestructure no ventilation

Flat window sill without water drop Dust and pollution collects on the windowsill and causes stains onto the cladding afterraining

WINDOW SILL

Advice Make a window sill with a 10 slopeminimum and a water drop with 30 mm gapfrom the cladding

Flat metal window sill

30mm

Advice Use a perforated metal ending profile and raise the cladding boards 5mm above the profile

no ventilation

Visible screwWater storage

Hidden screw

Perforated closure profile ventilation and water runoff

5mm

ENDINGS JUNCTIONS

Absence of water drop Water drop

REMARQUES IMPORTANTES SUR LA POSECAUTION

THE FULL INSTALLATION MANUAL OF COVER CLADDING PANELS IS AVAILABLE AT

wwwneolife-solutionscom

NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters

disposal for any clarifications concerning the installation procedure of its products

The specifications and recommendations given in the installation guide are not a

substitute to regulations concerning safety environment and professional regulatory

dispositions

All instructions concerning the installation of our cladding are to be followed

Assembly errors are not covered by the NEOLIFEreg guarantee

An approved fitter shall be able to assess the construction conformity to the local

professional installation guidelines

MAINTENANCE

21

Depending on the boards dirt after implementation (presence of mud dust etchellip) especially in the

grooves rain stains can appear on the surface

NEOLIFE strongly recommend to clean the boards after implementation with a pressure

washer following the boardsrsquo orientation (distance of min 20cm from the board DO NOT

USE a rotary nozzle)

Recommendations

Do not forget to clean the window shelves as well avoiding so any risk of dust stains on the

cladding after the first rain (windows are frequently dusty during construction)

All metal joineries (windows parapet capping etchellip) have to have a drip-edge flashing in

order to limit the water runoff on the cladding Shop signs or any other elements installed on

the cladding have to be moved forward (space left between cladding and the element) to

avoid any stains

Caution

If any operation involving the use of asphalt or concrete occurs after facade completion

NEOLIFE recommend to protect the cladding with a plastic cover in order to avoid stains

Indeed if not protected a greasy steam can spread on the surface and in the grooves In that

case a grease-removing product will be needed to clean the boards and all the surrounding

elements

BUILDING SITE CLEANING

LONG LASTING

VERY LIMITED MAINTENANCE

The material does not require any wood preservative (oils varnishes saturators hellip)

bull The VESTAreg material is naturally equivalent to use class 4(service environment In contact with ground or fresh water amp Permanently exposed to wetting The use classes rank the risk of exposure to decay and insect attack for differing in service environments according to EN 335 ndash 2)

bull Highly hydrophobic and rot-proof no algae fungi or moss development

bull Insect-resistant does not require any treatments against termites

STAIN REMOVAL

STAINS

Tanin stains

During the first weeks after installation tannin rings may occur because of the rain especially

on claddings with a light colour They will be washed off and fade during the next rain to

lessen until they completely disappear Be careful not to mistake these stains with dust or

pollution stains which appear on all cladding types

Bleach-based cleaning products

Slight discolouration Clean with water and complete if needed with slight brushing in the

boards orientation

Graffities oil paint and ink

Use a specialised stain remover (ex laquo STG 105 BIO raquo de STG)

Bitumen grease

Use a specialised stain remover (ex laquo Scalp Aqua 03 raquo)

Oxidation stains after contact with a corroded metal

Use a specialised wood de-greyer (ex laquo Scalp Neutral DA 66 raquo)

Caution

- Analyse properly the substance to clean so to use the right stain removing product

- Always test the stain removing product on a small and discrete surface before cleaning the

entire board

- It is mandatory that you analyse on a long time scale (and after exposure to Uvs) that the

solution you choose will not react with the cladding and therefore produce unsightly effects

DAMAGES

bull Scratches cigarette marks abrasion Brush away with a brass brush (lengthways)

TECHNICAL CHARACTERISTICS

25

SYSTEM PERFORMANCES

DESIGNATIONTEST

METHODS amp STANDARDS

CLADDING OUTLIFE COVER 6 amp 14

WIND LOAD (Depression) COVER 6 (4 ribs) COVER 14 (2 ribss)

Fixings description Eurocodes EN 1991-1-4 Test results Maximum shearing

pressure Test results Maximum shearingpressure

Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction

4 900 Pa

(degradation)140 kNm2 5 200 Pa

(degradation) 148 kNm2

Maximum 400mm centre-to-centre support spacing with one fixing tab at every junction 8 300 Pa (ruine) 237 kNm2 8 300 Pa (ruine) 237 kNm2

IMPACT RESISTANCE COVER 6 (4 ribs) COVER 14 (2 ribs)

Fixings description NF P 08302 Test results Test results

Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction

No damage with the impact energies below

Soft impacts 50Kg 130J

Soft impacts 3Kg 20J

Hard impacts 1Kg 3J

No damage with the impact energies below Soft impacts 50Kg 130J

Soft impacts 3Kg 20JHard impacts 1Kg 3J

SEISMIC RESISTANCE COVER 6 amp14

COVER 6 amp 14can be installed in seismic zones and buildings according to the following details

Highest seismic behaviour following Eurocode 8 no risk of falling boards or permanent deformations after static and dynamic test

FIRE RESISTANCE COVER 6 COVER 14

Tests description EN 13823 et EN 13501-12007

Fire rating

(on A2-s1d0 wall)

Fire rating

(on A2-s1d0 wall)

SBI test carried out on 3 models forming a 1500mm high 1000mm long and 500mm wide

dihedral wedge Assembly on air board and horizontal wood batten Valable contre un

substrat A2-s1d0

B-s3d0

Equivalent UK class 0

FIGRA average 1151Ws

THR average 6MJ

SMOGRA average 371 m2s2

B-s3d0

Equivalent UK class 0

FIGRA average 1924Ws

THR average 112MJ

SMOGRA average 592m2s2

Horizontal installation Class B-s3 d0 - Vertical installation on metal framework Class B s3 d0 on wooden framework Class C s3 d0 (EN 13501-12007)

PHYSICAL AND MECHANICAL FEATURES

DESIGNATION TEST METHODES amp STANDARDS COVER 6 amp 14 OUTLIFE CLADDING

FLAMMABLE MASS COVER 6 COVER 14Tests description NF EN 13238 Flammable mass per sqm (MJ)Tests realised according to the crucible method on at least 5 product samples 334 MJ 285 MJ

APPEARANCE DURABILITY(ageing under QUV) COVER 6 amp 14

Test descriptionNF EN 927-6 (2006)

FCBA‐ LBO6-PHY‐001

Test results

Artificial ageing test under QUV allowing an assessment of durability and decorative

properties modification Total duration 10 weeks comprising

condensation UV radiation and water spray phases

Stable products according to the EN 927-2

No blistering defects are observed according to ISO 4628-2 standard Resultt 0No cracking defects are observed according to ISO 4628-4 standard Result 0No flaking defects are observed according to ISO 4628-5 standard Result 0

THERMAL EXPANSION COVER 6 amp 14

Test description

ISO 11359-2 adapted to

FCBA - LBO6PHY-001

Test results

Thermodilatometric test in climatic room going from -20deg to +60deg to determine the profils

thermal expansion coefficient in solid state

Coefficient de dilatation thermique moyen

Longitudinally δL = 380 degK-1 10-6 standard spacing 210 degK-1 10-6 For uninstalled boardsTransversally δB = 575 degK-1 10-6 standard spacing 211 degK-1 10-6 For uninstalled boards

WATER UPTAKE DETERMINATION COVER 6 amp 14

Test description FCBA‐LBO‐MECA‐014 Test results

Water uptake determination after immersion in cold water during 28 days Measure of the

mass in its initial state and after 124714 et 28 days

Boards suitable to use in class 4 (Wood use class NF EN 335-2)Boards naturally resistant against fungus and soft rotAverage water uptake after 28 days 803Water content at 28 days and imputed to the cellulosic matter 143

ELASTICITY CONSTRAINS AND MODULE IN FLEXION COVER 6 amp 14

Test description

FCBA‐LBO‐MECA‐008

NF EN 310 modifiedWPC profiles

Test results

3 point flexion under normal conditions 20degCand 65 RH

Eaverage = 904 Nmm2fm = 40 Nmm2

ENVIRONMENTAL CHARACTERISTICS

28

VESTAreg ECO-MATERIAL

VESTAreg (Vegetal Ecological Stable Timber

Advantage) is an innovative and eco-friendly compound

with exceptional properties It was developed by

NEOCOreg NEOLIFEreglsquos Research Centre specialising in

green technologies in partnership with European experts

EXCEPTIONAL WOOD FIBER CONTENTVESTAreg revolutionises eco-materials and the design of

environmental solutions for construction projects and the

landscaping of outside spaces It finally brings a response

to the architects landscapers and design officesrsquo

demands working on eco-construction and sustainable

development projects

ECO-FRIENDLYThe wood fibres contained in VESTAreg come exclusively

from sawmills offcuts the wood coming from sustainably

managed European forests The production of our material

does not require the cutting of any trees and does not use treated wood from recycled pallets Moreover

NEOLIFE does not use any toxic additives in the production process of the material

VESTAreg is 100 recyclable with a perfect traceability it only contains virgin substances (no recycled

components for which establishing a traceability is impossible)

CLEANDoes not contain solvents adhesives or phthalates and does not generate

toxic emissions

STABLE AND RESISTANTVESTAreg fibres benefit from a thermal treatment which provides hydrophobic properties to the material The

formula reinforced with mineral resin lignin and antioxidants enables a remarkable mechanical resistance as

well as an outstanding design

The mineral pigments also offer a strong resistance to UV rays making the colours more durable whatever the

exposure

SOURCE

Raw material VESTAreg

X-FIRE is highly fire-resistant Wood fibres coming from sustainably managed European forests

Board Production France

COMPOSITIONby Volume 75 wood fibres mineral oil mineral salts mineral pigments

PHYSICAL PROPERTIES

Mass sqm COVER 6 195 kgmsup2 COVER 14 165 kgmsup2

Density 1500 kgm3

Parasite resistance Equivalent to use class 4 No development of fungal rot mosses or mould Insect-resistant including termites

Surface appearance Micro-striated surface splinter free blisters or flakes off Maintenance-free

Scratches resistance Equivalent to natural wood - Brushing possible without discolouration

Thermal inertia Low thermal inertia due to the high wood fibres content

ENVIRONMENTAL PROPERTIES

Recycling 100 recyclable 75 renewable and combustible (75 biomass)

Toxic substances Contains no toxic or dangerous products (according to Reach Regulation EC19072006)

Chemical fire retardant substance None

Solvents None

Heavy metals None lead-and mercury-free stabilization

Phthalates adhesives None

Formaldehydes and VOCs Lower than or equal to natural wood

VESTAreg REINFORCED WOOD FIBER

VESTA X-FIRE

ENVIRONMENTAL PRODUCT DECLARATION

1 - Values describing the environmental impacts

Owner of the declaration NEOLIFE Editor BUREAU VERITAS CODDE Declaration reference DEP_NEOLIFE_COVER_201507

Publication 10072015 Validity 10072020

Complies with the standard ISO 14025 NF EN 15804+A1 And itrsquos national addendum X P01-064CN

Environmental Declaration of the COVER productavailable on request

ENVIRONMENTAL PRODUCT DECLARATION

2 ndash Values describing the use of primary energetic sources other resources and water

3 ndash Complementary values describing the outflows

FURTHER DETAILS

33

TECHNICAL DESCRIPTION

French accreditaion type laquo Avis Technique Expeacuterimental de Type A raquo issued by CSTB (France)

Ndeg2278 ndash Available at httpevaluationcstbfrrechercherproduits-evaluesprestations=atex

VESTA Reinforced Wood Fiber cladding containing at least 75 wood fibres

Boards with a slatted aspect featuring 6 cm or 14 cm ribs

Fire rating with natural mineral salts following EN 13501-12007

COVER 6 B-s3-d0 minimum

COVER 14 B-s3-d0 minimum

Invisible fixing with stainless steel hooks screwed into wood or metal battens

Fast and accurate fitting thanks to the interlocking board system

Outside corners catered for by using 45deg miter cuts or aluminium corner profile

Dimensional stability of maximum 2mm m over ∆80degC

rot-proof not sensitive to moss and mould

Insect-resistant termites included

Stable colors after natural patina is acquired

Contact us to get the full technical specification sheet

CONTACT

CAUTION

This technical sheet is associated with the technical installation guide of CLAD claddingboard available at wwwneolife-solutionscom

NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters

disposal for any clarifications concerning the installation procedure of its products

The specifications and recommendations given in the installation guide are not a

substitute to regulations concerning safety environment and professional regulatory

dispositions

All instructions concerning the installation of our cladding are to be followed

Assembly errors are not covered by the NEOLIFEreg guarantee

An approved fitter shall be able to assess the construction conformity to the local

professional installation guidelines

304 Route Nationale 6 ndash Celtic Parc Bacirctiment Avalon II - 69760 Limonest FranceTel +33 (0)4 78 25 63 08 ndash Fax +33 (0)4 72 29 29 47

wwwneolife-solutionscom

Page 13: COVER 6 & 14 CLADDING · 2020. 11. 3. · 60 cm centre-to-centre spacing 10 / m ... sill and causes stains onto the cladding after raining WINDOW SILL Advice : Make a window sill

REMARQUES IMPORTANTES SUR LA POSE

BOARD PREPARATION Length 325 cm (tolerance of +0 20 mm)

Width 320 mm visible width when installed = 300mm (tolerance of plusmn 255 mm)

Thickness 285 mm (tolerance of plusmn 115 mm)

Squaring has to be done on site

Boards have to be calibrated according to layout

START Vertical installation Start with a metal or Aluminium profile It is highly recommended to install all the

boards in the same orientation in order to obtain a uniform colour Indeed the random brushing

creates an effect on the surface that capture the lights differently according the boards orientation

Pose horizontale Boards have to be installed with the groove at the bottom and the tongue at the top

IMPORTANT NOTICES

All instructions concerning the installation of our cladding are to be followed

Assembly errors are not covered by the NEOLIFEreg guarantee

An approved fitter shall be able to assess the construction conformity to the local

professional installation guidelines

Groove at the bottom

Horizontal intallation

Tongue at the top

Verticalinstallation

Profil alu de deacutepart visseacute

Screwed aluminium starting profile

REMARQUES IMPORTANTES SUR LA POSE

ALWAYS KEEP A 6 MM EXPANSION JOINT

A minimum space of 6mm between the 325m boards

and contiguous elements (joinery wall other cladding

boards) should be left to enable the natural expansion

of the NEOLIFEreg cladding boards

Always maintain 15 mm expansion per linear meter

(or 2mm in case of high temperature variations)

IMPORTANT NOTICES

NOT FOR STRUCTURAL USE Under no circumstances should the cladding boards be used for load-bearing or structural purposes

The professional rules and recommendations governing the cladding installation must be followed

NO SEALING PROPERTIES The boards are not designed to ensure the watertightness of the external facade

They should be used with a rainscreen wherever itrsquos required which will provide the weatherproofing

element in compliance with the local Building Regulations

FIXING ADDITIONAL ITEMS TO THE FACADE The cladding is not load-bearing

Anything fixed to the facade must be attached to the supporting structure behind the cladding

6mm

CAUTIONThe specifications and recommendations given in the NEOLIFEreg installation guide available at

wwwneolife-solutionscom website are not a substitute to regulations concerning safety

environment and regulatory installation specifications

REMARQUES IMPORTANTES SUR LA POSEIMPORTANT NOTICES

The panels have always to be fixed on each end at less than 1 cm of the boardrsquos edge

both in horizontal and vertical installations

EPDM strip

Concrete wall

1 Batten min size 60mmOr 2 battens min size 27x40mm

6 mm expansion joint

PREPARATION OF THE STRUCTURE

CAUTION

Make sure to respect the cladding installation steps recommended by the local professional guidelines

IMPORTANT ADVICES

The supporting structure (wood or metal) has to be perfectly flat to get a perfect facade The installation has to be planned on a ventilated wood structure with a minimum batten size of

27x40mm or on omega metal profiles 30x30x30 with a 400 ou 600 mm centre to centre distance

following the buildingrsquos category and height

The supporting structure can be fitted on every kind of walls (wood metal concrete) with or without

external insulation

Always keep a minimum 2cm air gap for ventilation behind the cladding (check the

recommendations of the local regulations )

The supporting structure has to be placed perpendicular to the cladding For vertical installation

the ventilation will be enabled through the claddingrsquos ribs or thanks to a crossed structure (following

the local recommendations)

Wide board With 300 mm width

KEY INSTALLATION PRINCIPLES

Mitre cut with perfectly aligned grooving

Horizontal or vertical fitting with various layouts

Invisible fixing using steel hooks screwed into the wood or metal supporting structures

Fast fixing using screwed steel hooks

NEOLIFEreg COVER claddingcan be fitted using all the conventional facade and covering accessories

Vertical fitting with a corner profile

6mm open expansion gapat the end of the board

Horizontal fittingwith a mitre cut

or with a corner profile

Metal CopingWindow revealwith metal profile

Outside corner or window reveal with Neolife corner profile

KEY INSTALLATION PRINCIPLES

DESIGN GUIDELINES

When the sign is installed onto the claddingwith no water runoff possibility It will cause stains on the claddingwhen drying (due to the mix of dust andpollution)

Flat metall elements without watertightnessmanagement Dirty water runoff causes stains

Advice

Leave space between cladding and the signand fix it on the load-bearing wall

INSTALLATION OF SHOP SIGN

OTHERS

Sign stuck onto the wall Sign away from the wall

Advice Install the element before the cladding bymanaging the waterlightness against the wallPlan a 10 slope and a waterdrop in order toavoid a water runoff onto the cladding

infiltration Seal and fixing

Cutting for expansion

Flat Casquette

Fixing againstthe wall

Absence of water drop Water drop

DESIGN GUIDELINES

BEST PRACTICEFind all the best practices in the NEOLIFEreg installation guide

available on our website wwwneolife-solutionscom

Closed metal profile at the junction betweencladding render no water runoffpossibility risk of stains and moisture on thestructure no ventilation

Flat window sill without water drop Dust and pollution collects on the windowsill and causes stains onto the cladding afterraining

WINDOW SILL

Advice Make a window sill with a 10 slopeminimum and a water drop with 30 mm gapfrom the cladding

Flat metal window sill

30mm

Advice Use a perforated metal ending profile and raise the cladding boards 5mm above the profile

no ventilation

Visible screwWater storage

Hidden screw

Perforated closure profile ventilation and water runoff

5mm

ENDINGS JUNCTIONS

Absence of water drop Water drop

REMARQUES IMPORTANTES SUR LA POSECAUTION

THE FULL INSTALLATION MANUAL OF COVER CLADDING PANELS IS AVAILABLE AT

wwwneolife-solutionscom

NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters

disposal for any clarifications concerning the installation procedure of its products

The specifications and recommendations given in the installation guide are not a

substitute to regulations concerning safety environment and professional regulatory

dispositions

All instructions concerning the installation of our cladding are to be followed

Assembly errors are not covered by the NEOLIFEreg guarantee

An approved fitter shall be able to assess the construction conformity to the local

professional installation guidelines

MAINTENANCE

21

Depending on the boards dirt after implementation (presence of mud dust etchellip) especially in the

grooves rain stains can appear on the surface

NEOLIFE strongly recommend to clean the boards after implementation with a pressure

washer following the boardsrsquo orientation (distance of min 20cm from the board DO NOT

USE a rotary nozzle)

Recommendations

Do not forget to clean the window shelves as well avoiding so any risk of dust stains on the

cladding after the first rain (windows are frequently dusty during construction)

All metal joineries (windows parapet capping etchellip) have to have a drip-edge flashing in

order to limit the water runoff on the cladding Shop signs or any other elements installed on

the cladding have to be moved forward (space left between cladding and the element) to

avoid any stains

Caution

If any operation involving the use of asphalt or concrete occurs after facade completion

NEOLIFE recommend to protect the cladding with a plastic cover in order to avoid stains

Indeed if not protected a greasy steam can spread on the surface and in the grooves In that

case a grease-removing product will be needed to clean the boards and all the surrounding

elements

BUILDING SITE CLEANING

LONG LASTING

VERY LIMITED MAINTENANCE

The material does not require any wood preservative (oils varnishes saturators hellip)

bull The VESTAreg material is naturally equivalent to use class 4(service environment In contact with ground or fresh water amp Permanently exposed to wetting The use classes rank the risk of exposure to decay and insect attack for differing in service environments according to EN 335 ndash 2)

bull Highly hydrophobic and rot-proof no algae fungi or moss development

bull Insect-resistant does not require any treatments against termites

STAIN REMOVAL

STAINS

Tanin stains

During the first weeks after installation tannin rings may occur because of the rain especially

on claddings with a light colour They will be washed off and fade during the next rain to

lessen until they completely disappear Be careful not to mistake these stains with dust or

pollution stains which appear on all cladding types

Bleach-based cleaning products

Slight discolouration Clean with water and complete if needed with slight brushing in the

boards orientation

Graffities oil paint and ink

Use a specialised stain remover (ex laquo STG 105 BIO raquo de STG)

Bitumen grease

Use a specialised stain remover (ex laquo Scalp Aqua 03 raquo)

Oxidation stains after contact with a corroded metal

Use a specialised wood de-greyer (ex laquo Scalp Neutral DA 66 raquo)

Caution

- Analyse properly the substance to clean so to use the right stain removing product

- Always test the stain removing product on a small and discrete surface before cleaning the

entire board

- It is mandatory that you analyse on a long time scale (and after exposure to Uvs) that the

solution you choose will not react with the cladding and therefore produce unsightly effects

DAMAGES

bull Scratches cigarette marks abrasion Brush away with a brass brush (lengthways)

TECHNICAL CHARACTERISTICS

25

SYSTEM PERFORMANCES

DESIGNATIONTEST

METHODS amp STANDARDS

CLADDING OUTLIFE COVER 6 amp 14

WIND LOAD (Depression) COVER 6 (4 ribs) COVER 14 (2 ribss)

Fixings description Eurocodes EN 1991-1-4 Test results Maximum shearing

pressure Test results Maximum shearingpressure

Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction

4 900 Pa

(degradation)140 kNm2 5 200 Pa

(degradation) 148 kNm2

Maximum 400mm centre-to-centre support spacing with one fixing tab at every junction 8 300 Pa (ruine) 237 kNm2 8 300 Pa (ruine) 237 kNm2

IMPACT RESISTANCE COVER 6 (4 ribs) COVER 14 (2 ribs)

Fixings description NF P 08302 Test results Test results

Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction

No damage with the impact energies below

Soft impacts 50Kg 130J

Soft impacts 3Kg 20J

Hard impacts 1Kg 3J

No damage with the impact energies below Soft impacts 50Kg 130J

Soft impacts 3Kg 20JHard impacts 1Kg 3J

SEISMIC RESISTANCE COVER 6 amp14

COVER 6 amp 14can be installed in seismic zones and buildings according to the following details

Highest seismic behaviour following Eurocode 8 no risk of falling boards or permanent deformations after static and dynamic test

FIRE RESISTANCE COVER 6 COVER 14

Tests description EN 13823 et EN 13501-12007

Fire rating

(on A2-s1d0 wall)

Fire rating

(on A2-s1d0 wall)

SBI test carried out on 3 models forming a 1500mm high 1000mm long and 500mm wide

dihedral wedge Assembly on air board and horizontal wood batten Valable contre un

substrat A2-s1d0

B-s3d0

Equivalent UK class 0

FIGRA average 1151Ws

THR average 6MJ

SMOGRA average 371 m2s2

B-s3d0

Equivalent UK class 0

FIGRA average 1924Ws

THR average 112MJ

SMOGRA average 592m2s2

Horizontal installation Class B-s3 d0 - Vertical installation on metal framework Class B s3 d0 on wooden framework Class C s3 d0 (EN 13501-12007)

PHYSICAL AND MECHANICAL FEATURES

DESIGNATION TEST METHODES amp STANDARDS COVER 6 amp 14 OUTLIFE CLADDING

FLAMMABLE MASS COVER 6 COVER 14Tests description NF EN 13238 Flammable mass per sqm (MJ)Tests realised according to the crucible method on at least 5 product samples 334 MJ 285 MJ

APPEARANCE DURABILITY(ageing under QUV) COVER 6 amp 14

Test descriptionNF EN 927-6 (2006)

FCBA‐ LBO6-PHY‐001

Test results

Artificial ageing test under QUV allowing an assessment of durability and decorative

properties modification Total duration 10 weeks comprising

condensation UV radiation and water spray phases

Stable products according to the EN 927-2

No blistering defects are observed according to ISO 4628-2 standard Resultt 0No cracking defects are observed according to ISO 4628-4 standard Result 0No flaking defects are observed according to ISO 4628-5 standard Result 0

THERMAL EXPANSION COVER 6 amp 14

Test description

ISO 11359-2 adapted to

FCBA - LBO6PHY-001

Test results

Thermodilatometric test in climatic room going from -20deg to +60deg to determine the profils

thermal expansion coefficient in solid state

Coefficient de dilatation thermique moyen

Longitudinally δL = 380 degK-1 10-6 standard spacing 210 degK-1 10-6 For uninstalled boardsTransversally δB = 575 degK-1 10-6 standard spacing 211 degK-1 10-6 For uninstalled boards

WATER UPTAKE DETERMINATION COVER 6 amp 14

Test description FCBA‐LBO‐MECA‐014 Test results

Water uptake determination after immersion in cold water during 28 days Measure of the

mass in its initial state and after 124714 et 28 days

Boards suitable to use in class 4 (Wood use class NF EN 335-2)Boards naturally resistant against fungus and soft rotAverage water uptake after 28 days 803Water content at 28 days and imputed to the cellulosic matter 143

ELASTICITY CONSTRAINS AND MODULE IN FLEXION COVER 6 amp 14

Test description

FCBA‐LBO‐MECA‐008

NF EN 310 modifiedWPC profiles

Test results

3 point flexion under normal conditions 20degCand 65 RH

Eaverage = 904 Nmm2fm = 40 Nmm2

ENVIRONMENTAL CHARACTERISTICS

28

VESTAreg ECO-MATERIAL

VESTAreg (Vegetal Ecological Stable Timber

Advantage) is an innovative and eco-friendly compound

with exceptional properties It was developed by

NEOCOreg NEOLIFEreglsquos Research Centre specialising in

green technologies in partnership with European experts

EXCEPTIONAL WOOD FIBER CONTENTVESTAreg revolutionises eco-materials and the design of

environmental solutions for construction projects and the

landscaping of outside spaces It finally brings a response

to the architects landscapers and design officesrsquo

demands working on eco-construction and sustainable

development projects

ECO-FRIENDLYThe wood fibres contained in VESTAreg come exclusively

from sawmills offcuts the wood coming from sustainably

managed European forests The production of our material

does not require the cutting of any trees and does not use treated wood from recycled pallets Moreover

NEOLIFE does not use any toxic additives in the production process of the material

VESTAreg is 100 recyclable with a perfect traceability it only contains virgin substances (no recycled

components for which establishing a traceability is impossible)

CLEANDoes not contain solvents adhesives or phthalates and does not generate

toxic emissions

STABLE AND RESISTANTVESTAreg fibres benefit from a thermal treatment which provides hydrophobic properties to the material The

formula reinforced with mineral resin lignin and antioxidants enables a remarkable mechanical resistance as

well as an outstanding design

The mineral pigments also offer a strong resistance to UV rays making the colours more durable whatever the

exposure

SOURCE

Raw material VESTAreg

X-FIRE is highly fire-resistant Wood fibres coming from sustainably managed European forests

Board Production France

COMPOSITIONby Volume 75 wood fibres mineral oil mineral salts mineral pigments

PHYSICAL PROPERTIES

Mass sqm COVER 6 195 kgmsup2 COVER 14 165 kgmsup2

Density 1500 kgm3

Parasite resistance Equivalent to use class 4 No development of fungal rot mosses or mould Insect-resistant including termites

Surface appearance Micro-striated surface splinter free blisters or flakes off Maintenance-free

Scratches resistance Equivalent to natural wood - Brushing possible without discolouration

Thermal inertia Low thermal inertia due to the high wood fibres content

ENVIRONMENTAL PROPERTIES

Recycling 100 recyclable 75 renewable and combustible (75 biomass)

Toxic substances Contains no toxic or dangerous products (according to Reach Regulation EC19072006)

Chemical fire retardant substance None

Solvents None

Heavy metals None lead-and mercury-free stabilization

Phthalates adhesives None

Formaldehydes and VOCs Lower than or equal to natural wood

VESTAreg REINFORCED WOOD FIBER

VESTA X-FIRE

ENVIRONMENTAL PRODUCT DECLARATION

1 - Values describing the environmental impacts

Owner of the declaration NEOLIFE Editor BUREAU VERITAS CODDE Declaration reference DEP_NEOLIFE_COVER_201507

Publication 10072015 Validity 10072020

Complies with the standard ISO 14025 NF EN 15804+A1 And itrsquos national addendum X P01-064CN

Environmental Declaration of the COVER productavailable on request

ENVIRONMENTAL PRODUCT DECLARATION

2 ndash Values describing the use of primary energetic sources other resources and water

3 ndash Complementary values describing the outflows

FURTHER DETAILS

33

TECHNICAL DESCRIPTION

French accreditaion type laquo Avis Technique Expeacuterimental de Type A raquo issued by CSTB (France)

Ndeg2278 ndash Available at httpevaluationcstbfrrechercherproduits-evaluesprestations=atex

VESTA Reinforced Wood Fiber cladding containing at least 75 wood fibres

Boards with a slatted aspect featuring 6 cm or 14 cm ribs

Fire rating with natural mineral salts following EN 13501-12007

COVER 6 B-s3-d0 minimum

COVER 14 B-s3-d0 minimum

Invisible fixing with stainless steel hooks screwed into wood or metal battens

Fast and accurate fitting thanks to the interlocking board system

Outside corners catered for by using 45deg miter cuts or aluminium corner profile

Dimensional stability of maximum 2mm m over ∆80degC

rot-proof not sensitive to moss and mould

Insect-resistant termites included

Stable colors after natural patina is acquired

Contact us to get the full technical specification sheet

CONTACT

CAUTION

This technical sheet is associated with the technical installation guide of CLAD claddingboard available at wwwneolife-solutionscom

NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters

disposal for any clarifications concerning the installation procedure of its products

The specifications and recommendations given in the installation guide are not a

substitute to regulations concerning safety environment and professional regulatory

dispositions

All instructions concerning the installation of our cladding are to be followed

Assembly errors are not covered by the NEOLIFEreg guarantee

An approved fitter shall be able to assess the construction conformity to the local

professional installation guidelines

304 Route Nationale 6 ndash Celtic Parc Bacirctiment Avalon II - 69760 Limonest FranceTel +33 (0)4 78 25 63 08 ndash Fax +33 (0)4 72 29 29 47

wwwneolife-solutionscom

Page 14: COVER 6 & 14 CLADDING · 2020. 11. 3. · 60 cm centre-to-centre spacing 10 / m ... sill and causes stains onto the cladding after raining WINDOW SILL Advice : Make a window sill

REMARQUES IMPORTANTES SUR LA POSE

ALWAYS KEEP A 6 MM EXPANSION JOINT

A minimum space of 6mm between the 325m boards

and contiguous elements (joinery wall other cladding

boards) should be left to enable the natural expansion

of the NEOLIFEreg cladding boards

Always maintain 15 mm expansion per linear meter

(or 2mm in case of high temperature variations)

IMPORTANT NOTICES

NOT FOR STRUCTURAL USE Under no circumstances should the cladding boards be used for load-bearing or structural purposes

The professional rules and recommendations governing the cladding installation must be followed

NO SEALING PROPERTIES The boards are not designed to ensure the watertightness of the external facade

They should be used with a rainscreen wherever itrsquos required which will provide the weatherproofing

element in compliance with the local Building Regulations

FIXING ADDITIONAL ITEMS TO THE FACADE The cladding is not load-bearing

Anything fixed to the facade must be attached to the supporting structure behind the cladding

6mm

CAUTIONThe specifications and recommendations given in the NEOLIFEreg installation guide available at

wwwneolife-solutionscom website are not a substitute to regulations concerning safety

environment and regulatory installation specifications

REMARQUES IMPORTANTES SUR LA POSEIMPORTANT NOTICES

The panels have always to be fixed on each end at less than 1 cm of the boardrsquos edge

both in horizontal and vertical installations

EPDM strip

Concrete wall

1 Batten min size 60mmOr 2 battens min size 27x40mm

6 mm expansion joint

PREPARATION OF THE STRUCTURE

CAUTION

Make sure to respect the cladding installation steps recommended by the local professional guidelines

IMPORTANT ADVICES

The supporting structure (wood or metal) has to be perfectly flat to get a perfect facade The installation has to be planned on a ventilated wood structure with a minimum batten size of

27x40mm or on omega metal profiles 30x30x30 with a 400 ou 600 mm centre to centre distance

following the buildingrsquos category and height

The supporting structure can be fitted on every kind of walls (wood metal concrete) with or without

external insulation

Always keep a minimum 2cm air gap for ventilation behind the cladding (check the

recommendations of the local regulations )

The supporting structure has to be placed perpendicular to the cladding For vertical installation

the ventilation will be enabled through the claddingrsquos ribs or thanks to a crossed structure (following

the local recommendations)

Wide board With 300 mm width

KEY INSTALLATION PRINCIPLES

Mitre cut with perfectly aligned grooving

Horizontal or vertical fitting with various layouts

Invisible fixing using steel hooks screwed into the wood or metal supporting structures

Fast fixing using screwed steel hooks

NEOLIFEreg COVER claddingcan be fitted using all the conventional facade and covering accessories

Vertical fitting with a corner profile

6mm open expansion gapat the end of the board

Horizontal fittingwith a mitre cut

or with a corner profile

Metal CopingWindow revealwith metal profile

Outside corner or window reveal with Neolife corner profile

KEY INSTALLATION PRINCIPLES

DESIGN GUIDELINES

When the sign is installed onto the claddingwith no water runoff possibility It will cause stains on the claddingwhen drying (due to the mix of dust andpollution)

Flat metall elements without watertightnessmanagement Dirty water runoff causes stains

Advice

Leave space between cladding and the signand fix it on the load-bearing wall

INSTALLATION OF SHOP SIGN

OTHERS

Sign stuck onto the wall Sign away from the wall

Advice Install the element before the cladding bymanaging the waterlightness against the wallPlan a 10 slope and a waterdrop in order toavoid a water runoff onto the cladding

infiltration Seal and fixing

Cutting for expansion

Flat Casquette

Fixing againstthe wall

Absence of water drop Water drop

DESIGN GUIDELINES

BEST PRACTICEFind all the best practices in the NEOLIFEreg installation guide

available on our website wwwneolife-solutionscom

Closed metal profile at the junction betweencladding render no water runoffpossibility risk of stains and moisture on thestructure no ventilation

Flat window sill without water drop Dust and pollution collects on the windowsill and causes stains onto the cladding afterraining

WINDOW SILL

Advice Make a window sill with a 10 slopeminimum and a water drop with 30 mm gapfrom the cladding

Flat metal window sill

30mm

Advice Use a perforated metal ending profile and raise the cladding boards 5mm above the profile

no ventilation

Visible screwWater storage

Hidden screw

Perforated closure profile ventilation and water runoff

5mm

ENDINGS JUNCTIONS

Absence of water drop Water drop

REMARQUES IMPORTANTES SUR LA POSECAUTION

THE FULL INSTALLATION MANUAL OF COVER CLADDING PANELS IS AVAILABLE AT

wwwneolife-solutionscom

NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters

disposal for any clarifications concerning the installation procedure of its products

The specifications and recommendations given in the installation guide are not a

substitute to regulations concerning safety environment and professional regulatory

dispositions

All instructions concerning the installation of our cladding are to be followed

Assembly errors are not covered by the NEOLIFEreg guarantee

An approved fitter shall be able to assess the construction conformity to the local

professional installation guidelines

MAINTENANCE

21

Depending on the boards dirt after implementation (presence of mud dust etchellip) especially in the

grooves rain stains can appear on the surface

NEOLIFE strongly recommend to clean the boards after implementation with a pressure

washer following the boardsrsquo orientation (distance of min 20cm from the board DO NOT

USE a rotary nozzle)

Recommendations

Do not forget to clean the window shelves as well avoiding so any risk of dust stains on the

cladding after the first rain (windows are frequently dusty during construction)

All metal joineries (windows parapet capping etchellip) have to have a drip-edge flashing in

order to limit the water runoff on the cladding Shop signs or any other elements installed on

the cladding have to be moved forward (space left between cladding and the element) to

avoid any stains

Caution

If any operation involving the use of asphalt or concrete occurs after facade completion

NEOLIFE recommend to protect the cladding with a plastic cover in order to avoid stains

Indeed if not protected a greasy steam can spread on the surface and in the grooves In that

case a grease-removing product will be needed to clean the boards and all the surrounding

elements

BUILDING SITE CLEANING

LONG LASTING

VERY LIMITED MAINTENANCE

The material does not require any wood preservative (oils varnishes saturators hellip)

bull The VESTAreg material is naturally equivalent to use class 4(service environment In contact with ground or fresh water amp Permanently exposed to wetting The use classes rank the risk of exposure to decay and insect attack for differing in service environments according to EN 335 ndash 2)

bull Highly hydrophobic and rot-proof no algae fungi or moss development

bull Insect-resistant does not require any treatments against termites

STAIN REMOVAL

STAINS

Tanin stains

During the first weeks after installation tannin rings may occur because of the rain especially

on claddings with a light colour They will be washed off and fade during the next rain to

lessen until they completely disappear Be careful not to mistake these stains with dust or

pollution stains which appear on all cladding types

Bleach-based cleaning products

Slight discolouration Clean with water and complete if needed with slight brushing in the

boards orientation

Graffities oil paint and ink

Use a specialised stain remover (ex laquo STG 105 BIO raquo de STG)

Bitumen grease

Use a specialised stain remover (ex laquo Scalp Aqua 03 raquo)

Oxidation stains after contact with a corroded metal

Use a specialised wood de-greyer (ex laquo Scalp Neutral DA 66 raquo)

Caution

- Analyse properly the substance to clean so to use the right stain removing product

- Always test the stain removing product on a small and discrete surface before cleaning the

entire board

- It is mandatory that you analyse on a long time scale (and after exposure to Uvs) that the

solution you choose will not react with the cladding and therefore produce unsightly effects

DAMAGES

bull Scratches cigarette marks abrasion Brush away with a brass brush (lengthways)

TECHNICAL CHARACTERISTICS

25

SYSTEM PERFORMANCES

DESIGNATIONTEST

METHODS amp STANDARDS

CLADDING OUTLIFE COVER 6 amp 14

WIND LOAD (Depression) COVER 6 (4 ribs) COVER 14 (2 ribss)

Fixings description Eurocodes EN 1991-1-4 Test results Maximum shearing

pressure Test results Maximum shearingpressure

Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction

4 900 Pa

(degradation)140 kNm2 5 200 Pa

(degradation) 148 kNm2

Maximum 400mm centre-to-centre support spacing with one fixing tab at every junction 8 300 Pa (ruine) 237 kNm2 8 300 Pa (ruine) 237 kNm2

IMPACT RESISTANCE COVER 6 (4 ribs) COVER 14 (2 ribs)

Fixings description NF P 08302 Test results Test results

Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction

No damage with the impact energies below

Soft impacts 50Kg 130J

Soft impacts 3Kg 20J

Hard impacts 1Kg 3J

No damage with the impact energies below Soft impacts 50Kg 130J

Soft impacts 3Kg 20JHard impacts 1Kg 3J

SEISMIC RESISTANCE COVER 6 amp14

COVER 6 amp 14can be installed in seismic zones and buildings according to the following details

Highest seismic behaviour following Eurocode 8 no risk of falling boards or permanent deformations after static and dynamic test

FIRE RESISTANCE COVER 6 COVER 14

Tests description EN 13823 et EN 13501-12007

Fire rating

(on A2-s1d0 wall)

Fire rating

(on A2-s1d0 wall)

SBI test carried out on 3 models forming a 1500mm high 1000mm long and 500mm wide

dihedral wedge Assembly on air board and horizontal wood batten Valable contre un

substrat A2-s1d0

B-s3d0

Equivalent UK class 0

FIGRA average 1151Ws

THR average 6MJ

SMOGRA average 371 m2s2

B-s3d0

Equivalent UK class 0

FIGRA average 1924Ws

THR average 112MJ

SMOGRA average 592m2s2

Horizontal installation Class B-s3 d0 - Vertical installation on metal framework Class B s3 d0 on wooden framework Class C s3 d0 (EN 13501-12007)

PHYSICAL AND MECHANICAL FEATURES

DESIGNATION TEST METHODES amp STANDARDS COVER 6 amp 14 OUTLIFE CLADDING

FLAMMABLE MASS COVER 6 COVER 14Tests description NF EN 13238 Flammable mass per sqm (MJ)Tests realised according to the crucible method on at least 5 product samples 334 MJ 285 MJ

APPEARANCE DURABILITY(ageing under QUV) COVER 6 amp 14

Test descriptionNF EN 927-6 (2006)

FCBA‐ LBO6-PHY‐001

Test results

Artificial ageing test under QUV allowing an assessment of durability and decorative

properties modification Total duration 10 weeks comprising

condensation UV radiation and water spray phases

Stable products according to the EN 927-2

No blistering defects are observed according to ISO 4628-2 standard Resultt 0No cracking defects are observed according to ISO 4628-4 standard Result 0No flaking defects are observed according to ISO 4628-5 standard Result 0

THERMAL EXPANSION COVER 6 amp 14

Test description

ISO 11359-2 adapted to

FCBA - LBO6PHY-001

Test results

Thermodilatometric test in climatic room going from -20deg to +60deg to determine the profils

thermal expansion coefficient in solid state

Coefficient de dilatation thermique moyen

Longitudinally δL = 380 degK-1 10-6 standard spacing 210 degK-1 10-6 For uninstalled boardsTransversally δB = 575 degK-1 10-6 standard spacing 211 degK-1 10-6 For uninstalled boards

WATER UPTAKE DETERMINATION COVER 6 amp 14

Test description FCBA‐LBO‐MECA‐014 Test results

Water uptake determination after immersion in cold water during 28 days Measure of the

mass in its initial state and after 124714 et 28 days

Boards suitable to use in class 4 (Wood use class NF EN 335-2)Boards naturally resistant against fungus and soft rotAverage water uptake after 28 days 803Water content at 28 days and imputed to the cellulosic matter 143

ELASTICITY CONSTRAINS AND MODULE IN FLEXION COVER 6 amp 14

Test description

FCBA‐LBO‐MECA‐008

NF EN 310 modifiedWPC profiles

Test results

3 point flexion under normal conditions 20degCand 65 RH

Eaverage = 904 Nmm2fm = 40 Nmm2

ENVIRONMENTAL CHARACTERISTICS

28

VESTAreg ECO-MATERIAL

VESTAreg (Vegetal Ecological Stable Timber

Advantage) is an innovative and eco-friendly compound

with exceptional properties It was developed by

NEOCOreg NEOLIFEreglsquos Research Centre specialising in

green technologies in partnership with European experts

EXCEPTIONAL WOOD FIBER CONTENTVESTAreg revolutionises eco-materials and the design of

environmental solutions for construction projects and the

landscaping of outside spaces It finally brings a response

to the architects landscapers and design officesrsquo

demands working on eco-construction and sustainable

development projects

ECO-FRIENDLYThe wood fibres contained in VESTAreg come exclusively

from sawmills offcuts the wood coming from sustainably

managed European forests The production of our material

does not require the cutting of any trees and does not use treated wood from recycled pallets Moreover

NEOLIFE does not use any toxic additives in the production process of the material

VESTAreg is 100 recyclable with a perfect traceability it only contains virgin substances (no recycled

components for which establishing a traceability is impossible)

CLEANDoes not contain solvents adhesives or phthalates and does not generate

toxic emissions

STABLE AND RESISTANTVESTAreg fibres benefit from a thermal treatment which provides hydrophobic properties to the material The

formula reinforced with mineral resin lignin and antioxidants enables a remarkable mechanical resistance as

well as an outstanding design

The mineral pigments also offer a strong resistance to UV rays making the colours more durable whatever the

exposure

SOURCE

Raw material VESTAreg

X-FIRE is highly fire-resistant Wood fibres coming from sustainably managed European forests

Board Production France

COMPOSITIONby Volume 75 wood fibres mineral oil mineral salts mineral pigments

PHYSICAL PROPERTIES

Mass sqm COVER 6 195 kgmsup2 COVER 14 165 kgmsup2

Density 1500 kgm3

Parasite resistance Equivalent to use class 4 No development of fungal rot mosses or mould Insect-resistant including termites

Surface appearance Micro-striated surface splinter free blisters or flakes off Maintenance-free

Scratches resistance Equivalent to natural wood - Brushing possible without discolouration

Thermal inertia Low thermal inertia due to the high wood fibres content

ENVIRONMENTAL PROPERTIES

Recycling 100 recyclable 75 renewable and combustible (75 biomass)

Toxic substances Contains no toxic or dangerous products (according to Reach Regulation EC19072006)

Chemical fire retardant substance None

Solvents None

Heavy metals None lead-and mercury-free stabilization

Phthalates adhesives None

Formaldehydes and VOCs Lower than or equal to natural wood

VESTAreg REINFORCED WOOD FIBER

VESTA X-FIRE

ENVIRONMENTAL PRODUCT DECLARATION

1 - Values describing the environmental impacts

Owner of the declaration NEOLIFE Editor BUREAU VERITAS CODDE Declaration reference DEP_NEOLIFE_COVER_201507

Publication 10072015 Validity 10072020

Complies with the standard ISO 14025 NF EN 15804+A1 And itrsquos national addendum X P01-064CN

Environmental Declaration of the COVER productavailable on request

ENVIRONMENTAL PRODUCT DECLARATION

2 ndash Values describing the use of primary energetic sources other resources and water

3 ndash Complementary values describing the outflows

FURTHER DETAILS

33

TECHNICAL DESCRIPTION

French accreditaion type laquo Avis Technique Expeacuterimental de Type A raquo issued by CSTB (France)

Ndeg2278 ndash Available at httpevaluationcstbfrrechercherproduits-evaluesprestations=atex

VESTA Reinforced Wood Fiber cladding containing at least 75 wood fibres

Boards with a slatted aspect featuring 6 cm or 14 cm ribs

Fire rating with natural mineral salts following EN 13501-12007

COVER 6 B-s3-d0 minimum

COVER 14 B-s3-d0 minimum

Invisible fixing with stainless steel hooks screwed into wood or metal battens

Fast and accurate fitting thanks to the interlocking board system

Outside corners catered for by using 45deg miter cuts or aluminium corner profile

Dimensional stability of maximum 2mm m over ∆80degC

rot-proof not sensitive to moss and mould

Insect-resistant termites included

Stable colors after natural patina is acquired

Contact us to get the full technical specification sheet

CONTACT

CAUTION

This technical sheet is associated with the technical installation guide of CLAD claddingboard available at wwwneolife-solutionscom

NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters

disposal for any clarifications concerning the installation procedure of its products

The specifications and recommendations given in the installation guide are not a

substitute to regulations concerning safety environment and professional regulatory

dispositions

All instructions concerning the installation of our cladding are to be followed

Assembly errors are not covered by the NEOLIFEreg guarantee

An approved fitter shall be able to assess the construction conformity to the local

professional installation guidelines

304 Route Nationale 6 ndash Celtic Parc Bacirctiment Avalon II - 69760 Limonest FranceTel +33 (0)4 78 25 63 08 ndash Fax +33 (0)4 72 29 29 47

wwwneolife-solutionscom

Page 15: COVER 6 & 14 CLADDING · 2020. 11. 3. · 60 cm centre-to-centre spacing 10 / m ... sill and causes stains onto the cladding after raining WINDOW SILL Advice : Make a window sill

REMARQUES IMPORTANTES SUR LA POSEIMPORTANT NOTICES

The panels have always to be fixed on each end at less than 1 cm of the boardrsquos edge

both in horizontal and vertical installations

EPDM strip

Concrete wall

1 Batten min size 60mmOr 2 battens min size 27x40mm

6 mm expansion joint

PREPARATION OF THE STRUCTURE

CAUTION

Make sure to respect the cladding installation steps recommended by the local professional guidelines

IMPORTANT ADVICES

The supporting structure (wood or metal) has to be perfectly flat to get a perfect facade The installation has to be planned on a ventilated wood structure with a minimum batten size of

27x40mm or on omega metal profiles 30x30x30 with a 400 ou 600 mm centre to centre distance

following the buildingrsquos category and height

The supporting structure can be fitted on every kind of walls (wood metal concrete) with or without

external insulation

Always keep a minimum 2cm air gap for ventilation behind the cladding (check the

recommendations of the local regulations )

The supporting structure has to be placed perpendicular to the cladding For vertical installation

the ventilation will be enabled through the claddingrsquos ribs or thanks to a crossed structure (following

the local recommendations)

Wide board With 300 mm width

KEY INSTALLATION PRINCIPLES

Mitre cut with perfectly aligned grooving

Horizontal or vertical fitting with various layouts

Invisible fixing using steel hooks screwed into the wood or metal supporting structures

Fast fixing using screwed steel hooks

NEOLIFEreg COVER claddingcan be fitted using all the conventional facade and covering accessories

Vertical fitting with a corner profile

6mm open expansion gapat the end of the board

Horizontal fittingwith a mitre cut

or with a corner profile

Metal CopingWindow revealwith metal profile

Outside corner or window reveal with Neolife corner profile

KEY INSTALLATION PRINCIPLES

DESIGN GUIDELINES

When the sign is installed onto the claddingwith no water runoff possibility It will cause stains on the claddingwhen drying (due to the mix of dust andpollution)

Flat metall elements without watertightnessmanagement Dirty water runoff causes stains

Advice

Leave space between cladding and the signand fix it on the load-bearing wall

INSTALLATION OF SHOP SIGN

OTHERS

Sign stuck onto the wall Sign away from the wall

Advice Install the element before the cladding bymanaging the waterlightness against the wallPlan a 10 slope and a waterdrop in order toavoid a water runoff onto the cladding

infiltration Seal and fixing

Cutting for expansion

Flat Casquette

Fixing againstthe wall

Absence of water drop Water drop

DESIGN GUIDELINES

BEST PRACTICEFind all the best practices in the NEOLIFEreg installation guide

available on our website wwwneolife-solutionscom

Closed metal profile at the junction betweencladding render no water runoffpossibility risk of stains and moisture on thestructure no ventilation

Flat window sill without water drop Dust and pollution collects on the windowsill and causes stains onto the cladding afterraining

WINDOW SILL

Advice Make a window sill with a 10 slopeminimum and a water drop with 30 mm gapfrom the cladding

Flat metal window sill

30mm

Advice Use a perforated metal ending profile and raise the cladding boards 5mm above the profile

no ventilation

Visible screwWater storage

Hidden screw

Perforated closure profile ventilation and water runoff

5mm

ENDINGS JUNCTIONS

Absence of water drop Water drop

REMARQUES IMPORTANTES SUR LA POSECAUTION

THE FULL INSTALLATION MANUAL OF COVER CLADDING PANELS IS AVAILABLE AT

wwwneolife-solutionscom

NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters

disposal for any clarifications concerning the installation procedure of its products

The specifications and recommendations given in the installation guide are not a

substitute to regulations concerning safety environment and professional regulatory

dispositions

All instructions concerning the installation of our cladding are to be followed

Assembly errors are not covered by the NEOLIFEreg guarantee

An approved fitter shall be able to assess the construction conformity to the local

professional installation guidelines

MAINTENANCE

21

Depending on the boards dirt after implementation (presence of mud dust etchellip) especially in the

grooves rain stains can appear on the surface

NEOLIFE strongly recommend to clean the boards after implementation with a pressure

washer following the boardsrsquo orientation (distance of min 20cm from the board DO NOT

USE a rotary nozzle)

Recommendations

Do not forget to clean the window shelves as well avoiding so any risk of dust stains on the

cladding after the first rain (windows are frequently dusty during construction)

All metal joineries (windows parapet capping etchellip) have to have a drip-edge flashing in

order to limit the water runoff on the cladding Shop signs or any other elements installed on

the cladding have to be moved forward (space left between cladding and the element) to

avoid any stains

Caution

If any operation involving the use of asphalt or concrete occurs after facade completion

NEOLIFE recommend to protect the cladding with a plastic cover in order to avoid stains

Indeed if not protected a greasy steam can spread on the surface and in the grooves In that

case a grease-removing product will be needed to clean the boards and all the surrounding

elements

BUILDING SITE CLEANING

LONG LASTING

VERY LIMITED MAINTENANCE

The material does not require any wood preservative (oils varnishes saturators hellip)

bull The VESTAreg material is naturally equivalent to use class 4(service environment In contact with ground or fresh water amp Permanently exposed to wetting The use classes rank the risk of exposure to decay and insect attack for differing in service environments according to EN 335 ndash 2)

bull Highly hydrophobic and rot-proof no algae fungi or moss development

bull Insect-resistant does not require any treatments against termites

STAIN REMOVAL

STAINS

Tanin stains

During the first weeks after installation tannin rings may occur because of the rain especially

on claddings with a light colour They will be washed off and fade during the next rain to

lessen until they completely disappear Be careful not to mistake these stains with dust or

pollution stains which appear on all cladding types

Bleach-based cleaning products

Slight discolouration Clean with water and complete if needed with slight brushing in the

boards orientation

Graffities oil paint and ink

Use a specialised stain remover (ex laquo STG 105 BIO raquo de STG)

Bitumen grease

Use a specialised stain remover (ex laquo Scalp Aqua 03 raquo)

Oxidation stains after contact with a corroded metal

Use a specialised wood de-greyer (ex laquo Scalp Neutral DA 66 raquo)

Caution

- Analyse properly the substance to clean so to use the right stain removing product

- Always test the stain removing product on a small and discrete surface before cleaning the

entire board

- It is mandatory that you analyse on a long time scale (and after exposure to Uvs) that the

solution you choose will not react with the cladding and therefore produce unsightly effects

DAMAGES

bull Scratches cigarette marks abrasion Brush away with a brass brush (lengthways)

TECHNICAL CHARACTERISTICS

25

SYSTEM PERFORMANCES

DESIGNATIONTEST

METHODS amp STANDARDS

CLADDING OUTLIFE COVER 6 amp 14

WIND LOAD (Depression) COVER 6 (4 ribs) COVER 14 (2 ribss)

Fixings description Eurocodes EN 1991-1-4 Test results Maximum shearing

pressure Test results Maximum shearingpressure

Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction

4 900 Pa

(degradation)140 kNm2 5 200 Pa

(degradation) 148 kNm2

Maximum 400mm centre-to-centre support spacing with one fixing tab at every junction 8 300 Pa (ruine) 237 kNm2 8 300 Pa (ruine) 237 kNm2

IMPACT RESISTANCE COVER 6 (4 ribs) COVER 14 (2 ribs)

Fixings description NF P 08302 Test results Test results

Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction

No damage with the impact energies below

Soft impacts 50Kg 130J

Soft impacts 3Kg 20J

Hard impacts 1Kg 3J

No damage with the impact energies below Soft impacts 50Kg 130J

Soft impacts 3Kg 20JHard impacts 1Kg 3J

SEISMIC RESISTANCE COVER 6 amp14

COVER 6 amp 14can be installed in seismic zones and buildings according to the following details

Highest seismic behaviour following Eurocode 8 no risk of falling boards or permanent deformations after static and dynamic test

FIRE RESISTANCE COVER 6 COVER 14

Tests description EN 13823 et EN 13501-12007

Fire rating

(on A2-s1d0 wall)

Fire rating

(on A2-s1d0 wall)

SBI test carried out on 3 models forming a 1500mm high 1000mm long and 500mm wide

dihedral wedge Assembly on air board and horizontal wood batten Valable contre un

substrat A2-s1d0

B-s3d0

Equivalent UK class 0

FIGRA average 1151Ws

THR average 6MJ

SMOGRA average 371 m2s2

B-s3d0

Equivalent UK class 0

FIGRA average 1924Ws

THR average 112MJ

SMOGRA average 592m2s2

Horizontal installation Class B-s3 d0 - Vertical installation on metal framework Class B s3 d0 on wooden framework Class C s3 d0 (EN 13501-12007)

PHYSICAL AND MECHANICAL FEATURES

DESIGNATION TEST METHODES amp STANDARDS COVER 6 amp 14 OUTLIFE CLADDING

FLAMMABLE MASS COVER 6 COVER 14Tests description NF EN 13238 Flammable mass per sqm (MJ)Tests realised according to the crucible method on at least 5 product samples 334 MJ 285 MJ

APPEARANCE DURABILITY(ageing under QUV) COVER 6 amp 14

Test descriptionNF EN 927-6 (2006)

FCBA‐ LBO6-PHY‐001

Test results

Artificial ageing test under QUV allowing an assessment of durability and decorative

properties modification Total duration 10 weeks comprising

condensation UV radiation and water spray phases

Stable products according to the EN 927-2

No blistering defects are observed according to ISO 4628-2 standard Resultt 0No cracking defects are observed according to ISO 4628-4 standard Result 0No flaking defects are observed according to ISO 4628-5 standard Result 0

THERMAL EXPANSION COVER 6 amp 14

Test description

ISO 11359-2 adapted to

FCBA - LBO6PHY-001

Test results

Thermodilatometric test in climatic room going from -20deg to +60deg to determine the profils

thermal expansion coefficient in solid state

Coefficient de dilatation thermique moyen

Longitudinally δL = 380 degK-1 10-6 standard spacing 210 degK-1 10-6 For uninstalled boardsTransversally δB = 575 degK-1 10-6 standard spacing 211 degK-1 10-6 For uninstalled boards

WATER UPTAKE DETERMINATION COVER 6 amp 14

Test description FCBA‐LBO‐MECA‐014 Test results

Water uptake determination after immersion in cold water during 28 days Measure of the

mass in its initial state and after 124714 et 28 days

Boards suitable to use in class 4 (Wood use class NF EN 335-2)Boards naturally resistant against fungus and soft rotAverage water uptake after 28 days 803Water content at 28 days and imputed to the cellulosic matter 143

ELASTICITY CONSTRAINS AND MODULE IN FLEXION COVER 6 amp 14

Test description

FCBA‐LBO‐MECA‐008

NF EN 310 modifiedWPC profiles

Test results

3 point flexion under normal conditions 20degCand 65 RH

Eaverage = 904 Nmm2fm = 40 Nmm2

ENVIRONMENTAL CHARACTERISTICS

28

VESTAreg ECO-MATERIAL

VESTAreg (Vegetal Ecological Stable Timber

Advantage) is an innovative and eco-friendly compound

with exceptional properties It was developed by

NEOCOreg NEOLIFEreglsquos Research Centre specialising in

green technologies in partnership with European experts

EXCEPTIONAL WOOD FIBER CONTENTVESTAreg revolutionises eco-materials and the design of

environmental solutions for construction projects and the

landscaping of outside spaces It finally brings a response

to the architects landscapers and design officesrsquo

demands working on eco-construction and sustainable

development projects

ECO-FRIENDLYThe wood fibres contained in VESTAreg come exclusively

from sawmills offcuts the wood coming from sustainably

managed European forests The production of our material

does not require the cutting of any trees and does not use treated wood from recycled pallets Moreover

NEOLIFE does not use any toxic additives in the production process of the material

VESTAreg is 100 recyclable with a perfect traceability it only contains virgin substances (no recycled

components for which establishing a traceability is impossible)

CLEANDoes not contain solvents adhesives or phthalates and does not generate

toxic emissions

STABLE AND RESISTANTVESTAreg fibres benefit from a thermal treatment which provides hydrophobic properties to the material The

formula reinforced with mineral resin lignin and antioxidants enables a remarkable mechanical resistance as

well as an outstanding design

The mineral pigments also offer a strong resistance to UV rays making the colours more durable whatever the

exposure

SOURCE

Raw material VESTAreg

X-FIRE is highly fire-resistant Wood fibres coming from sustainably managed European forests

Board Production France

COMPOSITIONby Volume 75 wood fibres mineral oil mineral salts mineral pigments

PHYSICAL PROPERTIES

Mass sqm COVER 6 195 kgmsup2 COVER 14 165 kgmsup2

Density 1500 kgm3

Parasite resistance Equivalent to use class 4 No development of fungal rot mosses or mould Insect-resistant including termites

Surface appearance Micro-striated surface splinter free blisters or flakes off Maintenance-free

Scratches resistance Equivalent to natural wood - Brushing possible without discolouration

Thermal inertia Low thermal inertia due to the high wood fibres content

ENVIRONMENTAL PROPERTIES

Recycling 100 recyclable 75 renewable and combustible (75 biomass)

Toxic substances Contains no toxic or dangerous products (according to Reach Regulation EC19072006)

Chemical fire retardant substance None

Solvents None

Heavy metals None lead-and mercury-free stabilization

Phthalates adhesives None

Formaldehydes and VOCs Lower than or equal to natural wood

VESTAreg REINFORCED WOOD FIBER

VESTA X-FIRE

ENVIRONMENTAL PRODUCT DECLARATION

1 - Values describing the environmental impacts

Owner of the declaration NEOLIFE Editor BUREAU VERITAS CODDE Declaration reference DEP_NEOLIFE_COVER_201507

Publication 10072015 Validity 10072020

Complies with the standard ISO 14025 NF EN 15804+A1 And itrsquos national addendum X P01-064CN

Environmental Declaration of the COVER productavailable on request

ENVIRONMENTAL PRODUCT DECLARATION

2 ndash Values describing the use of primary energetic sources other resources and water

3 ndash Complementary values describing the outflows

FURTHER DETAILS

33

TECHNICAL DESCRIPTION

French accreditaion type laquo Avis Technique Expeacuterimental de Type A raquo issued by CSTB (France)

Ndeg2278 ndash Available at httpevaluationcstbfrrechercherproduits-evaluesprestations=atex

VESTA Reinforced Wood Fiber cladding containing at least 75 wood fibres

Boards with a slatted aspect featuring 6 cm or 14 cm ribs

Fire rating with natural mineral salts following EN 13501-12007

COVER 6 B-s3-d0 minimum

COVER 14 B-s3-d0 minimum

Invisible fixing with stainless steel hooks screwed into wood or metal battens

Fast and accurate fitting thanks to the interlocking board system

Outside corners catered for by using 45deg miter cuts or aluminium corner profile

Dimensional stability of maximum 2mm m over ∆80degC

rot-proof not sensitive to moss and mould

Insect-resistant termites included

Stable colors after natural patina is acquired

Contact us to get the full technical specification sheet

CONTACT

CAUTION

This technical sheet is associated with the technical installation guide of CLAD claddingboard available at wwwneolife-solutionscom

NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters

disposal for any clarifications concerning the installation procedure of its products

The specifications and recommendations given in the installation guide are not a

substitute to regulations concerning safety environment and professional regulatory

dispositions

All instructions concerning the installation of our cladding are to be followed

Assembly errors are not covered by the NEOLIFEreg guarantee

An approved fitter shall be able to assess the construction conformity to the local

professional installation guidelines

304 Route Nationale 6 ndash Celtic Parc Bacirctiment Avalon II - 69760 Limonest FranceTel +33 (0)4 78 25 63 08 ndash Fax +33 (0)4 72 29 29 47

wwwneolife-solutionscom

Page 16: COVER 6 & 14 CLADDING · 2020. 11. 3. · 60 cm centre-to-centre spacing 10 / m ... sill and causes stains onto the cladding after raining WINDOW SILL Advice : Make a window sill

Wide board With 300 mm width

KEY INSTALLATION PRINCIPLES

Mitre cut with perfectly aligned grooving

Horizontal or vertical fitting with various layouts

Invisible fixing using steel hooks screwed into the wood or metal supporting structures

Fast fixing using screwed steel hooks

NEOLIFEreg COVER claddingcan be fitted using all the conventional facade and covering accessories

Vertical fitting with a corner profile

6mm open expansion gapat the end of the board

Horizontal fittingwith a mitre cut

or with a corner profile

Metal CopingWindow revealwith metal profile

Outside corner or window reveal with Neolife corner profile

KEY INSTALLATION PRINCIPLES

DESIGN GUIDELINES

When the sign is installed onto the claddingwith no water runoff possibility It will cause stains on the claddingwhen drying (due to the mix of dust andpollution)

Flat metall elements without watertightnessmanagement Dirty water runoff causes stains

Advice

Leave space between cladding and the signand fix it on the load-bearing wall

INSTALLATION OF SHOP SIGN

OTHERS

Sign stuck onto the wall Sign away from the wall

Advice Install the element before the cladding bymanaging the waterlightness against the wallPlan a 10 slope and a waterdrop in order toavoid a water runoff onto the cladding

infiltration Seal and fixing

Cutting for expansion

Flat Casquette

Fixing againstthe wall

Absence of water drop Water drop

DESIGN GUIDELINES

BEST PRACTICEFind all the best practices in the NEOLIFEreg installation guide

available on our website wwwneolife-solutionscom

Closed metal profile at the junction betweencladding render no water runoffpossibility risk of stains and moisture on thestructure no ventilation

Flat window sill without water drop Dust and pollution collects on the windowsill and causes stains onto the cladding afterraining

WINDOW SILL

Advice Make a window sill with a 10 slopeminimum and a water drop with 30 mm gapfrom the cladding

Flat metal window sill

30mm

Advice Use a perforated metal ending profile and raise the cladding boards 5mm above the profile

no ventilation

Visible screwWater storage

Hidden screw

Perforated closure profile ventilation and water runoff

5mm

ENDINGS JUNCTIONS

Absence of water drop Water drop

REMARQUES IMPORTANTES SUR LA POSECAUTION

THE FULL INSTALLATION MANUAL OF COVER CLADDING PANELS IS AVAILABLE AT

wwwneolife-solutionscom

NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters

disposal for any clarifications concerning the installation procedure of its products

The specifications and recommendations given in the installation guide are not a

substitute to regulations concerning safety environment and professional regulatory

dispositions

All instructions concerning the installation of our cladding are to be followed

Assembly errors are not covered by the NEOLIFEreg guarantee

An approved fitter shall be able to assess the construction conformity to the local

professional installation guidelines

MAINTENANCE

21

Depending on the boards dirt after implementation (presence of mud dust etchellip) especially in the

grooves rain stains can appear on the surface

NEOLIFE strongly recommend to clean the boards after implementation with a pressure

washer following the boardsrsquo orientation (distance of min 20cm from the board DO NOT

USE a rotary nozzle)

Recommendations

Do not forget to clean the window shelves as well avoiding so any risk of dust stains on the

cladding after the first rain (windows are frequently dusty during construction)

All metal joineries (windows parapet capping etchellip) have to have a drip-edge flashing in

order to limit the water runoff on the cladding Shop signs or any other elements installed on

the cladding have to be moved forward (space left between cladding and the element) to

avoid any stains

Caution

If any operation involving the use of asphalt or concrete occurs after facade completion

NEOLIFE recommend to protect the cladding with a plastic cover in order to avoid stains

Indeed if not protected a greasy steam can spread on the surface and in the grooves In that

case a grease-removing product will be needed to clean the boards and all the surrounding

elements

BUILDING SITE CLEANING

LONG LASTING

VERY LIMITED MAINTENANCE

The material does not require any wood preservative (oils varnishes saturators hellip)

bull The VESTAreg material is naturally equivalent to use class 4(service environment In contact with ground or fresh water amp Permanently exposed to wetting The use classes rank the risk of exposure to decay and insect attack for differing in service environments according to EN 335 ndash 2)

bull Highly hydrophobic and rot-proof no algae fungi or moss development

bull Insect-resistant does not require any treatments against termites

STAIN REMOVAL

STAINS

Tanin stains

During the first weeks after installation tannin rings may occur because of the rain especially

on claddings with a light colour They will be washed off and fade during the next rain to

lessen until they completely disappear Be careful not to mistake these stains with dust or

pollution stains which appear on all cladding types

Bleach-based cleaning products

Slight discolouration Clean with water and complete if needed with slight brushing in the

boards orientation

Graffities oil paint and ink

Use a specialised stain remover (ex laquo STG 105 BIO raquo de STG)

Bitumen grease

Use a specialised stain remover (ex laquo Scalp Aqua 03 raquo)

Oxidation stains after contact with a corroded metal

Use a specialised wood de-greyer (ex laquo Scalp Neutral DA 66 raquo)

Caution

- Analyse properly the substance to clean so to use the right stain removing product

- Always test the stain removing product on a small and discrete surface before cleaning the

entire board

- It is mandatory that you analyse on a long time scale (and after exposure to Uvs) that the

solution you choose will not react with the cladding and therefore produce unsightly effects

DAMAGES

bull Scratches cigarette marks abrasion Brush away with a brass brush (lengthways)

TECHNICAL CHARACTERISTICS

25

SYSTEM PERFORMANCES

DESIGNATIONTEST

METHODS amp STANDARDS

CLADDING OUTLIFE COVER 6 amp 14

WIND LOAD (Depression) COVER 6 (4 ribs) COVER 14 (2 ribss)

Fixings description Eurocodes EN 1991-1-4 Test results Maximum shearing

pressure Test results Maximum shearingpressure

Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction

4 900 Pa

(degradation)140 kNm2 5 200 Pa

(degradation) 148 kNm2

Maximum 400mm centre-to-centre support spacing with one fixing tab at every junction 8 300 Pa (ruine) 237 kNm2 8 300 Pa (ruine) 237 kNm2

IMPACT RESISTANCE COVER 6 (4 ribs) COVER 14 (2 ribs)

Fixings description NF P 08302 Test results Test results

Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction

No damage with the impact energies below

Soft impacts 50Kg 130J

Soft impacts 3Kg 20J

Hard impacts 1Kg 3J

No damage with the impact energies below Soft impacts 50Kg 130J

Soft impacts 3Kg 20JHard impacts 1Kg 3J

SEISMIC RESISTANCE COVER 6 amp14

COVER 6 amp 14can be installed in seismic zones and buildings according to the following details

Highest seismic behaviour following Eurocode 8 no risk of falling boards or permanent deformations after static and dynamic test

FIRE RESISTANCE COVER 6 COVER 14

Tests description EN 13823 et EN 13501-12007

Fire rating

(on A2-s1d0 wall)

Fire rating

(on A2-s1d0 wall)

SBI test carried out on 3 models forming a 1500mm high 1000mm long and 500mm wide

dihedral wedge Assembly on air board and horizontal wood batten Valable contre un

substrat A2-s1d0

B-s3d0

Equivalent UK class 0

FIGRA average 1151Ws

THR average 6MJ

SMOGRA average 371 m2s2

B-s3d0

Equivalent UK class 0

FIGRA average 1924Ws

THR average 112MJ

SMOGRA average 592m2s2

Horizontal installation Class B-s3 d0 - Vertical installation on metal framework Class B s3 d0 on wooden framework Class C s3 d0 (EN 13501-12007)

PHYSICAL AND MECHANICAL FEATURES

DESIGNATION TEST METHODES amp STANDARDS COVER 6 amp 14 OUTLIFE CLADDING

FLAMMABLE MASS COVER 6 COVER 14Tests description NF EN 13238 Flammable mass per sqm (MJ)Tests realised according to the crucible method on at least 5 product samples 334 MJ 285 MJ

APPEARANCE DURABILITY(ageing under QUV) COVER 6 amp 14

Test descriptionNF EN 927-6 (2006)

FCBA‐ LBO6-PHY‐001

Test results

Artificial ageing test under QUV allowing an assessment of durability and decorative

properties modification Total duration 10 weeks comprising

condensation UV radiation and water spray phases

Stable products according to the EN 927-2

No blistering defects are observed according to ISO 4628-2 standard Resultt 0No cracking defects are observed according to ISO 4628-4 standard Result 0No flaking defects are observed according to ISO 4628-5 standard Result 0

THERMAL EXPANSION COVER 6 amp 14

Test description

ISO 11359-2 adapted to

FCBA - LBO6PHY-001

Test results

Thermodilatometric test in climatic room going from -20deg to +60deg to determine the profils

thermal expansion coefficient in solid state

Coefficient de dilatation thermique moyen

Longitudinally δL = 380 degK-1 10-6 standard spacing 210 degK-1 10-6 For uninstalled boardsTransversally δB = 575 degK-1 10-6 standard spacing 211 degK-1 10-6 For uninstalled boards

WATER UPTAKE DETERMINATION COVER 6 amp 14

Test description FCBA‐LBO‐MECA‐014 Test results

Water uptake determination after immersion in cold water during 28 days Measure of the

mass in its initial state and after 124714 et 28 days

Boards suitable to use in class 4 (Wood use class NF EN 335-2)Boards naturally resistant against fungus and soft rotAverage water uptake after 28 days 803Water content at 28 days and imputed to the cellulosic matter 143

ELASTICITY CONSTRAINS AND MODULE IN FLEXION COVER 6 amp 14

Test description

FCBA‐LBO‐MECA‐008

NF EN 310 modifiedWPC profiles

Test results

3 point flexion under normal conditions 20degCand 65 RH

Eaverage = 904 Nmm2fm = 40 Nmm2

ENVIRONMENTAL CHARACTERISTICS

28

VESTAreg ECO-MATERIAL

VESTAreg (Vegetal Ecological Stable Timber

Advantage) is an innovative and eco-friendly compound

with exceptional properties It was developed by

NEOCOreg NEOLIFEreglsquos Research Centre specialising in

green technologies in partnership with European experts

EXCEPTIONAL WOOD FIBER CONTENTVESTAreg revolutionises eco-materials and the design of

environmental solutions for construction projects and the

landscaping of outside spaces It finally brings a response

to the architects landscapers and design officesrsquo

demands working on eco-construction and sustainable

development projects

ECO-FRIENDLYThe wood fibres contained in VESTAreg come exclusively

from sawmills offcuts the wood coming from sustainably

managed European forests The production of our material

does not require the cutting of any trees and does not use treated wood from recycled pallets Moreover

NEOLIFE does not use any toxic additives in the production process of the material

VESTAreg is 100 recyclable with a perfect traceability it only contains virgin substances (no recycled

components for which establishing a traceability is impossible)

CLEANDoes not contain solvents adhesives or phthalates and does not generate

toxic emissions

STABLE AND RESISTANTVESTAreg fibres benefit from a thermal treatment which provides hydrophobic properties to the material The

formula reinforced with mineral resin lignin and antioxidants enables a remarkable mechanical resistance as

well as an outstanding design

The mineral pigments also offer a strong resistance to UV rays making the colours more durable whatever the

exposure

SOURCE

Raw material VESTAreg

X-FIRE is highly fire-resistant Wood fibres coming from sustainably managed European forests

Board Production France

COMPOSITIONby Volume 75 wood fibres mineral oil mineral salts mineral pigments

PHYSICAL PROPERTIES

Mass sqm COVER 6 195 kgmsup2 COVER 14 165 kgmsup2

Density 1500 kgm3

Parasite resistance Equivalent to use class 4 No development of fungal rot mosses or mould Insect-resistant including termites

Surface appearance Micro-striated surface splinter free blisters or flakes off Maintenance-free

Scratches resistance Equivalent to natural wood - Brushing possible without discolouration

Thermal inertia Low thermal inertia due to the high wood fibres content

ENVIRONMENTAL PROPERTIES

Recycling 100 recyclable 75 renewable and combustible (75 biomass)

Toxic substances Contains no toxic or dangerous products (according to Reach Regulation EC19072006)

Chemical fire retardant substance None

Solvents None

Heavy metals None lead-and mercury-free stabilization

Phthalates adhesives None

Formaldehydes and VOCs Lower than or equal to natural wood

VESTAreg REINFORCED WOOD FIBER

VESTA X-FIRE

ENVIRONMENTAL PRODUCT DECLARATION

1 - Values describing the environmental impacts

Owner of the declaration NEOLIFE Editor BUREAU VERITAS CODDE Declaration reference DEP_NEOLIFE_COVER_201507

Publication 10072015 Validity 10072020

Complies with the standard ISO 14025 NF EN 15804+A1 And itrsquos national addendum X P01-064CN

Environmental Declaration of the COVER productavailable on request

ENVIRONMENTAL PRODUCT DECLARATION

2 ndash Values describing the use of primary energetic sources other resources and water

3 ndash Complementary values describing the outflows

FURTHER DETAILS

33

TECHNICAL DESCRIPTION

French accreditaion type laquo Avis Technique Expeacuterimental de Type A raquo issued by CSTB (France)

Ndeg2278 ndash Available at httpevaluationcstbfrrechercherproduits-evaluesprestations=atex

VESTA Reinforced Wood Fiber cladding containing at least 75 wood fibres

Boards with a slatted aspect featuring 6 cm or 14 cm ribs

Fire rating with natural mineral salts following EN 13501-12007

COVER 6 B-s3-d0 minimum

COVER 14 B-s3-d0 minimum

Invisible fixing with stainless steel hooks screwed into wood or metal battens

Fast and accurate fitting thanks to the interlocking board system

Outside corners catered for by using 45deg miter cuts or aluminium corner profile

Dimensional stability of maximum 2mm m over ∆80degC

rot-proof not sensitive to moss and mould

Insect-resistant termites included

Stable colors after natural patina is acquired

Contact us to get the full technical specification sheet

CONTACT

CAUTION

This technical sheet is associated with the technical installation guide of CLAD claddingboard available at wwwneolife-solutionscom

NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters

disposal for any clarifications concerning the installation procedure of its products

The specifications and recommendations given in the installation guide are not a

substitute to regulations concerning safety environment and professional regulatory

dispositions

All instructions concerning the installation of our cladding are to be followed

Assembly errors are not covered by the NEOLIFEreg guarantee

An approved fitter shall be able to assess the construction conformity to the local

professional installation guidelines

304 Route Nationale 6 ndash Celtic Parc Bacirctiment Avalon II - 69760 Limonest FranceTel +33 (0)4 78 25 63 08 ndash Fax +33 (0)4 72 29 29 47

wwwneolife-solutionscom

Page 17: COVER 6 & 14 CLADDING · 2020. 11. 3. · 60 cm centre-to-centre spacing 10 / m ... sill and causes stains onto the cladding after raining WINDOW SILL Advice : Make a window sill

NEOLIFEreg COVER claddingcan be fitted using all the conventional facade and covering accessories

Vertical fitting with a corner profile

6mm open expansion gapat the end of the board

Horizontal fittingwith a mitre cut

or with a corner profile

Metal CopingWindow revealwith metal profile

Outside corner or window reveal with Neolife corner profile

KEY INSTALLATION PRINCIPLES

DESIGN GUIDELINES

When the sign is installed onto the claddingwith no water runoff possibility It will cause stains on the claddingwhen drying (due to the mix of dust andpollution)

Flat metall elements without watertightnessmanagement Dirty water runoff causes stains

Advice

Leave space between cladding and the signand fix it on the load-bearing wall

INSTALLATION OF SHOP SIGN

OTHERS

Sign stuck onto the wall Sign away from the wall

Advice Install the element before the cladding bymanaging the waterlightness against the wallPlan a 10 slope and a waterdrop in order toavoid a water runoff onto the cladding

infiltration Seal and fixing

Cutting for expansion

Flat Casquette

Fixing againstthe wall

Absence of water drop Water drop

DESIGN GUIDELINES

BEST PRACTICEFind all the best practices in the NEOLIFEreg installation guide

available on our website wwwneolife-solutionscom

Closed metal profile at the junction betweencladding render no water runoffpossibility risk of stains and moisture on thestructure no ventilation

Flat window sill without water drop Dust and pollution collects on the windowsill and causes stains onto the cladding afterraining

WINDOW SILL

Advice Make a window sill with a 10 slopeminimum and a water drop with 30 mm gapfrom the cladding

Flat metal window sill

30mm

Advice Use a perforated metal ending profile and raise the cladding boards 5mm above the profile

no ventilation

Visible screwWater storage

Hidden screw

Perforated closure profile ventilation and water runoff

5mm

ENDINGS JUNCTIONS

Absence of water drop Water drop

REMARQUES IMPORTANTES SUR LA POSECAUTION

THE FULL INSTALLATION MANUAL OF COVER CLADDING PANELS IS AVAILABLE AT

wwwneolife-solutionscom

NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters

disposal for any clarifications concerning the installation procedure of its products

The specifications and recommendations given in the installation guide are not a

substitute to regulations concerning safety environment and professional regulatory

dispositions

All instructions concerning the installation of our cladding are to be followed

Assembly errors are not covered by the NEOLIFEreg guarantee

An approved fitter shall be able to assess the construction conformity to the local

professional installation guidelines

MAINTENANCE

21

Depending on the boards dirt after implementation (presence of mud dust etchellip) especially in the

grooves rain stains can appear on the surface

NEOLIFE strongly recommend to clean the boards after implementation with a pressure

washer following the boardsrsquo orientation (distance of min 20cm from the board DO NOT

USE a rotary nozzle)

Recommendations

Do not forget to clean the window shelves as well avoiding so any risk of dust stains on the

cladding after the first rain (windows are frequently dusty during construction)

All metal joineries (windows parapet capping etchellip) have to have a drip-edge flashing in

order to limit the water runoff on the cladding Shop signs or any other elements installed on

the cladding have to be moved forward (space left between cladding and the element) to

avoid any stains

Caution

If any operation involving the use of asphalt or concrete occurs after facade completion

NEOLIFE recommend to protect the cladding with a plastic cover in order to avoid stains

Indeed if not protected a greasy steam can spread on the surface and in the grooves In that

case a grease-removing product will be needed to clean the boards and all the surrounding

elements

BUILDING SITE CLEANING

LONG LASTING

VERY LIMITED MAINTENANCE

The material does not require any wood preservative (oils varnishes saturators hellip)

bull The VESTAreg material is naturally equivalent to use class 4(service environment In contact with ground or fresh water amp Permanently exposed to wetting The use classes rank the risk of exposure to decay and insect attack for differing in service environments according to EN 335 ndash 2)

bull Highly hydrophobic and rot-proof no algae fungi or moss development

bull Insect-resistant does not require any treatments against termites

STAIN REMOVAL

STAINS

Tanin stains

During the first weeks after installation tannin rings may occur because of the rain especially

on claddings with a light colour They will be washed off and fade during the next rain to

lessen until they completely disappear Be careful not to mistake these stains with dust or

pollution stains which appear on all cladding types

Bleach-based cleaning products

Slight discolouration Clean with water and complete if needed with slight brushing in the

boards orientation

Graffities oil paint and ink

Use a specialised stain remover (ex laquo STG 105 BIO raquo de STG)

Bitumen grease

Use a specialised stain remover (ex laquo Scalp Aqua 03 raquo)

Oxidation stains after contact with a corroded metal

Use a specialised wood de-greyer (ex laquo Scalp Neutral DA 66 raquo)

Caution

- Analyse properly the substance to clean so to use the right stain removing product

- Always test the stain removing product on a small and discrete surface before cleaning the

entire board

- It is mandatory that you analyse on a long time scale (and after exposure to Uvs) that the

solution you choose will not react with the cladding and therefore produce unsightly effects

DAMAGES

bull Scratches cigarette marks abrasion Brush away with a brass brush (lengthways)

TECHNICAL CHARACTERISTICS

25

SYSTEM PERFORMANCES

DESIGNATIONTEST

METHODS amp STANDARDS

CLADDING OUTLIFE COVER 6 amp 14

WIND LOAD (Depression) COVER 6 (4 ribs) COVER 14 (2 ribss)

Fixings description Eurocodes EN 1991-1-4 Test results Maximum shearing

pressure Test results Maximum shearingpressure

Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction

4 900 Pa

(degradation)140 kNm2 5 200 Pa

(degradation) 148 kNm2

Maximum 400mm centre-to-centre support spacing with one fixing tab at every junction 8 300 Pa (ruine) 237 kNm2 8 300 Pa (ruine) 237 kNm2

IMPACT RESISTANCE COVER 6 (4 ribs) COVER 14 (2 ribs)

Fixings description NF P 08302 Test results Test results

Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction

No damage with the impact energies below

Soft impacts 50Kg 130J

Soft impacts 3Kg 20J

Hard impacts 1Kg 3J

No damage with the impact energies below Soft impacts 50Kg 130J

Soft impacts 3Kg 20JHard impacts 1Kg 3J

SEISMIC RESISTANCE COVER 6 amp14

COVER 6 amp 14can be installed in seismic zones and buildings according to the following details

Highest seismic behaviour following Eurocode 8 no risk of falling boards or permanent deformations after static and dynamic test

FIRE RESISTANCE COVER 6 COVER 14

Tests description EN 13823 et EN 13501-12007

Fire rating

(on A2-s1d0 wall)

Fire rating

(on A2-s1d0 wall)

SBI test carried out on 3 models forming a 1500mm high 1000mm long and 500mm wide

dihedral wedge Assembly on air board and horizontal wood batten Valable contre un

substrat A2-s1d0

B-s3d0

Equivalent UK class 0

FIGRA average 1151Ws

THR average 6MJ

SMOGRA average 371 m2s2

B-s3d0

Equivalent UK class 0

FIGRA average 1924Ws

THR average 112MJ

SMOGRA average 592m2s2

Horizontal installation Class B-s3 d0 - Vertical installation on metal framework Class B s3 d0 on wooden framework Class C s3 d0 (EN 13501-12007)

PHYSICAL AND MECHANICAL FEATURES

DESIGNATION TEST METHODES amp STANDARDS COVER 6 amp 14 OUTLIFE CLADDING

FLAMMABLE MASS COVER 6 COVER 14Tests description NF EN 13238 Flammable mass per sqm (MJ)Tests realised according to the crucible method on at least 5 product samples 334 MJ 285 MJ

APPEARANCE DURABILITY(ageing under QUV) COVER 6 amp 14

Test descriptionNF EN 927-6 (2006)

FCBA‐ LBO6-PHY‐001

Test results

Artificial ageing test under QUV allowing an assessment of durability and decorative

properties modification Total duration 10 weeks comprising

condensation UV radiation and water spray phases

Stable products according to the EN 927-2

No blistering defects are observed according to ISO 4628-2 standard Resultt 0No cracking defects are observed according to ISO 4628-4 standard Result 0No flaking defects are observed according to ISO 4628-5 standard Result 0

THERMAL EXPANSION COVER 6 amp 14

Test description

ISO 11359-2 adapted to

FCBA - LBO6PHY-001

Test results

Thermodilatometric test in climatic room going from -20deg to +60deg to determine the profils

thermal expansion coefficient in solid state

Coefficient de dilatation thermique moyen

Longitudinally δL = 380 degK-1 10-6 standard spacing 210 degK-1 10-6 For uninstalled boardsTransversally δB = 575 degK-1 10-6 standard spacing 211 degK-1 10-6 For uninstalled boards

WATER UPTAKE DETERMINATION COVER 6 amp 14

Test description FCBA‐LBO‐MECA‐014 Test results

Water uptake determination after immersion in cold water during 28 days Measure of the

mass in its initial state and after 124714 et 28 days

Boards suitable to use in class 4 (Wood use class NF EN 335-2)Boards naturally resistant against fungus and soft rotAverage water uptake after 28 days 803Water content at 28 days and imputed to the cellulosic matter 143

ELASTICITY CONSTRAINS AND MODULE IN FLEXION COVER 6 amp 14

Test description

FCBA‐LBO‐MECA‐008

NF EN 310 modifiedWPC profiles

Test results

3 point flexion under normal conditions 20degCand 65 RH

Eaverage = 904 Nmm2fm = 40 Nmm2

ENVIRONMENTAL CHARACTERISTICS

28

VESTAreg ECO-MATERIAL

VESTAreg (Vegetal Ecological Stable Timber

Advantage) is an innovative and eco-friendly compound

with exceptional properties It was developed by

NEOCOreg NEOLIFEreglsquos Research Centre specialising in

green technologies in partnership with European experts

EXCEPTIONAL WOOD FIBER CONTENTVESTAreg revolutionises eco-materials and the design of

environmental solutions for construction projects and the

landscaping of outside spaces It finally brings a response

to the architects landscapers and design officesrsquo

demands working on eco-construction and sustainable

development projects

ECO-FRIENDLYThe wood fibres contained in VESTAreg come exclusively

from sawmills offcuts the wood coming from sustainably

managed European forests The production of our material

does not require the cutting of any trees and does not use treated wood from recycled pallets Moreover

NEOLIFE does not use any toxic additives in the production process of the material

VESTAreg is 100 recyclable with a perfect traceability it only contains virgin substances (no recycled

components for which establishing a traceability is impossible)

CLEANDoes not contain solvents adhesives or phthalates and does not generate

toxic emissions

STABLE AND RESISTANTVESTAreg fibres benefit from a thermal treatment which provides hydrophobic properties to the material The

formula reinforced with mineral resin lignin and antioxidants enables a remarkable mechanical resistance as

well as an outstanding design

The mineral pigments also offer a strong resistance to UV rays making the colours more durable whatever the

exposure

SOURCE

Raw material VESTAreg

X-FIRE is highly fire-resistant Wood fibres coming from sustainably managed European forests

Board Production France

COMPOSITIONby Volume 75 wood fibres mineral oil mineral salts mineral pigments

PHYSICAL PROPERTIES

Mass sqm COVER 6 195 kgmsup2 COVER 14 165 kgmsup2

Density 1500 kgm3

Parasite resistance Equivalent to use class 4 No development of fungal rot mosses or mould Insect-resistant including termites

Surface appearance Micro-striated surface splinter free blisters or flakes off Maintenance-free

Scratches resistance Equivalent to natural wood - Brushing possible without discolouration

Thermal inertia Low thermal inertia due to the high wood fibres content

ENVIRONMENTAL PROPERTIES

Recycling 100 recyclable 75 renewable and combustible (75 biomass)

Toxic substances Contains no toxic or dangerous products (according to Reach Regulation EC19072006)

Chemical fire retardant substance None

Solvents None

Heavy metals None lead-and mercury-free stabilization

Phthalates adhesives None

Formaldehydes and VOCs Lower than or equal to natural wood

VESTAreg REINFORCED WOOD FIBER

VESTA X-FIRE

ENVIRONMENTAL PRODUCT DECLARATION

1 - Values describing the environmental impacts

Owner of the declaration NEOLIFE Editor BUREAU VERITAS CODDE Declaration reference DEP_NEOLIFE_COVER_201507

Publication 10072015 Validity 10072020

Complies with the standard ISO 14025 NF EN 15804+A1 And itrsquos national addendum X P01-064CN

Environmental Declaration of the COVER productavailable on request

ENVIRONMENTAL PRODUCT DECLARATION

2 ndash Values describing the use of primary energetic sources other resources and water

3 ndash Complementary values describing the outflows

FURTHER DETAILS

33

TECHNICAL DESCRIPTION

French accreditaion type laquo Avis Technique Expeacuterimental de Type A raquo issued by CSTB (France)

Ndeg2278 ndash Available at httpevaluationcstbfrrechercherproduits-evaluesprestations=atex

VESTA Reinforced Wood Fiber cladding containing at least 75 wood fibres

Boards with a slatted aspect featuring 6 cm or 14 cm ribs

Fire rating with natural mineral salts following EN 13501-12007

COVER 6 B-s3-d0 minimum

COVER 14 B-s3-d0 minimum

Invisible fixing with stainless steel hooks screwed into wood or metal battens

Fast and accurate fitting thanks to the interlocking board system

Outside corners catered for by using 45deg miter cuts or aluminium corner profile

Dimensional stability of maximum 2mm m over ∆80degC

rot-proof not sensitive to moss and mould

Insect-resistant termites included

Stable colors after natural patina is acquired

Contact us to get the full technical specification sheet

CONTACT

CAUTION

This technical sheet is associated with the technical installation guide of CLAD claddingboard available at wwwneolife-solutionscom

NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters

disposal for any clarifications concerning the installation procedure of its products

The specifications and recommendations given in the installation guide are not a

substitute to regulations concerning safety environment and professional regulatory

dispositions

All instructions concerning the installation of our cladding are to be followed

Assembly errors are not covered by the NEOLIFEreg guarantee

An approved fitter shall be able to assess the construction conformity to the local

professional installation guidelines

304 Route Nationale 6 ndash Celtic Parc Bacirctiment Avalon II - 69760 Limonest FranceTel +33 (0)4 78 25 63 08 ndash Fax +33 (0)4 72 29 29 47

wwwneolife-solutionscom

Page 18: COVER 6 & 14 CLADDING · 2020. 11. 3. · 60 cm centre-to-centre spacing 10 / m ... sill and causes stains onto the cladding after raining WINDOW SILL Advice : Make a window sill

DESIGN GUIDELINES

When the sign is installed onto the claddingwith no water runoff possibility It will cause stains on the claddingwhen drying (due to the mix of dust andpollution)

Flat metall elements without watertightnessmanagement Dirty water runoff causes stains

Advice

Leave space between cladding and the signand fix it on the load-bearing wall

INSTALLATION OF SHOP SIGN

OTHERS

Sign stuck onto the wall Sign away from the wall

Advice Install the element before the cladding bymanaging the waterlightness against the wallPlan a 10 slope and a waterdrop in order toavoid a water runoff onto the cladding

infiltration Seal and fixing

Cutting for expansion

Flat Casquette

Fixing againstthe wall

Absence of water drop Water drop

DESIGN GUIDELINES

BEST PRACTICEFind all the best practices in the NEOLIFEreg installation guide

available on our website wwwneolife-solutionscom

Closed metal profile at the junction betweencladding render no water runoffpossibility risk of stains and moisture on thestructure no ventilation

Flat window sill without water drop Dust and pollution collects on the windowsill and causes stains onto the cladding afterraining

WINDOW SILL

Advice Make a window sill with a 10 slopeminimum and a water drop with 30 mm gapfrom the cladding

Flat metal window sill

30mm

Advice Use a perforated metal ending profile and raise the cladding boards 5mm above the profile

no ventilation

Visible screwWater storage

Hidden screw

Perforated closure profile ventilation and water runoff

5mm

ENDINGS JUNCTIONS

Absence of water drop Water drop

REMARQUES IMPORTANTES SUR LA POSECAUTION

THE FULL INSTALLATION MANUAL OF COVER CLADDING PANELS IS AVAILABLE AT

wwwneolife-solutionscom

NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters

disposal for any clarifications concerning the installation procedure of its products

The specifications and recommendations given in the installation guide are not a

substitute to regulations concerning safety environment and professional regulatory

dispositions

All instructions concerning the installation of our cladding are to be followed

Assembly errors are not covered by the NEOLIFEreg guarantee

An approved fitter shall be able to assess the construction conformity to the local

professional installation guidelines

MAINTENANCE

21

Depending on the boards dirt after implementation (presence of mud dust etchellip) especially in the

grooves rain stains can appear on the surface

NEOLIFE strongly recommend to clean the boards after implementation with a pressure

washer following the boardsrsquo orientation (distance of min 20cm from the board DO NOT

USE a rotary nozzle)

Recommendations

Do not forget to clean the window shelves as well avoiding so any risk of dust stains on the

cladding after the first rain (windows are frequently dusty during construction)

All metal joineries (windows parapet capping etchellip) have to have a drip-edge flashing in

order to limit the water runoff on the cladding Shop signs or any other elements installed on

the cladding have to be moved forward (space left between cladding and the element) to

avoid any stains

Caution

If any operation involving the use of asphalt or concrete occurs after facade completion

NEOLIFE recommend to protect the cladding with a plastic cover in order to avoid stains

Indeed if not protected a greasy steam can spread on the surface and in the grooves In that

case a grease-removing product will be needed to clean the boards and all the surrounding

elements

BUILDING SITE CLEANING

LONG LASTING

VERY LIMITED MAINTENANCE

The material does not require any wood preservative (oils varnishes saturators hellip)

bull The VESTAreg material is naturally equivalent to use class 4(service environment In contact with ground or fresh water amp Permanently exposed to wetting The use classes rank the risk of exposure to decay and insect attack for differing in service environments according to EN 335 ndash 2)

bull Highly hydrophobic and rot-proof no algae fungi or moss development

bull Insect-resistant does not require any treatments against termites

STAIN REMOVAL

STAINS

Tanin stains

During the first weeks after installation tannin rings may occur because of the rain especially

on claddings with a light colour They will be washed off and fade during the next rain to

lessen until they completely disappear Be careful not to mistake these stains with dust or

pollution stains which appear on all cladding types

Bleach-based cleaning products

Slight discolouration Clean with water and complete if needed with slight brushing in the

boards orientation

Graffities oil paint and ink

Use a specialised stain remover (ex laquo STG 105 BIO raquo de STG)

Bitumen grease

Use a specialised stain remover (ex laquo Scalp Aqua 03 raquo)

Oxidation stains after contact with a corroded metal

Use a specialised wood de-greyer (ex laquo Scalp Neutral DA 66 raquo)

Caution

- Analyse properly the substance to clean so to use the right stain removing product

- Always test the stain removing product on a small and discrete surface before cleaning the

entire board

- It is mandatory that you analyse on a long time scale (and after exposure to Uvs) that the

solution you choose will not react with the cladding and therefore produce unsightly effects

DAMAGES

bull Scratches cigarette marks abrasion Brush away with a brass brush (lengthways)

TECHNICAL CHARACTERISTICS

25

SYSTEM PERFORMANCES

DESIGNATIONTEST

METHODS amp STANDARDS

CLADDING OUTLIFE COVER 6 amp 14

WIND LOAD (Depression) COVER 6 (4 ribs) COVER 14 (2 ribss)

Fixings description Eurocodes EN 1991-1-4 Test results Maximum shearing

pressure Test results Maximum shearingpressure

Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction

4 900 Pa

(degradation)140 kNm2 5 200 Pa

(degradation) 148 kNm2

Maximum 400mm centre-to-centre support spacing with one fixing tab at every junction 8 300 Pa (ruine) 237 kNm2 8 300 Pa (ruine) 237 kNm2

IMPACT RESISTANCE COVER 6 (4 ribs) COVER 14 (2 ribs)

Fixings description NF P 08302 Test results Test results

Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction

No damage with the impact energies below

Soft impacts 50Kg 130J

Soft impacts 3Kg 20J

Hard impacts 1Kg 3J

No damage with the impact energies below Soft impacts 50Kg 130J

Soft impacts 3Kg 20JHard impacts 1Kg 3J

SEISMIC RESISTANCE COVER 6 amp14

COVER 6 amp 14can be installed in seismic zones and buildings according to the following details

Highest seismic behaviour following Eurocode 8 no risk of falling boards or permanent deformations after static and dynamic test

FIRE RESISTANCE COVER 6 COVER 14

Tests description EN 13823 et EN 13501-12007

Fire rating

(on A2-s1d0 wall)

Fire rating

(on A2-s1d0 wall)

SBI test carried out on 3 models forming a 1500mm high 1000mm long and 500mm wide

dihedral wedge Assembly on air board and horizontal wood batten Valable contre un

substrat A2-s1d0

B-s3d0

Equivalent UK class 0

FIGRA average 1151Ws

THR average 6MJ

SMOGRA average 371 m2s2

B-s3d0

Equivalent UK class 0

FIGRA average 1924Ws

THR average 112MJ

SMOGRA average 592m2s2

Horizontal installation Class B-s3 d0 - Vertical installation on metal framework Class B s3 d0 on wooden framework Class C s3 d0 (EN 13501-12007)

PHYSICAL AND MECHANICAL FEATURES

DESIGNATION TEST METHODES amp STANDARDS COVER 6 amp 14 OUTLIFE CLADDING

FLAMMABLE MASS COVER 6 COVER 14Tests description NF EN 13238 Flammable mass per sqm (MJ)Tests realised according to the crucible method on at least 5 product samples 334 MJ 285 MJ

APPEARANCE DURABILITY(ageing under QUV) COVER 6 amp 14

Test descriptionNF EN 927-6 (2006)

FCBA‐ LBO6-PHY‐001

Test results

Artificial ageing test under QUV allowing an assessment of durability and decorative

properties modification Total duration 10 weeks comprising

condensation UV radiation and water spray phases

Stable products according to the EN 927-2

No blistering defects are observed according to ISO 4628-2 standard Resultt 0No cracking defects are observed according to ISO 4628-4 standard Result 0No flaking defects are observed according to ISO 4628-5 standard Result 0

THERMAL EXPANSION COVER 6 amp 14

Test description

ISO 11359-2 adapted to

FCBA - LBO6PHY-001

Test results

Thermodilatometric test in climatic room going from -20deg to +60deg to determine the profils

thermal expansion coefficient in solid state

Coefficient de dilatation thermique moyen

Longitudinally δL = 380 degK-1 10-6 standard spacing 210 degK-1 10-6 For uninstalled boardsTransversally δB = 575 degK-1 10-6 standard spacing 211 degK-1 10-6 For uninstalled boards

WATER UPTAKE DETERMINATION COVER 6 amp 14

Test description FCBA‐LBO‐MECA‐014 Test results

Water uptake determination after immersion in cold water during 28 days Measure of the

mass in its initial state and after 124714 et 28 days

Boards suitable to use in class 4 (Wood use class NF EN 335-2)Boards naturally resistant against fungus and soft rotAverage water uptake after 28 days 803Water content at 28 days and imputed to the cellulosic matter 143

ELASTICITY CONSTRAINS AND MODULE IN FLEXION COVER 6 amp 14

Test description

FCBA‐LBO‐MECA‐008

NF EN 310 modifiedWPC profiles

Test results

3 point flexion under normal conditions 20degCand 65 RH

Eaverage = 904 Nmm2fm = 40 Nmm2

ENVIRONMENTAL CHARACTERISTICS

28

VESTAreg ECO-MATERIAL

VESTAreg (Vegetal Ecological Stable Timber

Advantage) is an innovative and eco-friendly compound

with exceptional properties It was developed by

NEOCOreg NEOLIFEreglsquos Research Centre specialising in

green technologies in partnership with European experts

EXCEPTIONAL WOOD FIBER CONTENTVESTAreg revolutionises eco-materials and the design of

environmental solutions for construction projects and the

landscaping of outside spaces It finally brings a response

to the architects landscapers and design officesrsquo

demands working on eco-construction and sustainable

development projects

ECO-FRIENDLYThe wood fibres contained in VESTAreg come exclusively

from sawmills offcuts the wood coming from sustainably

managed European forests The production of our material

does not require the cutting of any trees and does not use treated wood from recycled pallets Moreover

NEOLIFE does not use any toxic additives in the production process of the material

VESTAreg is 100 recyclable with a perfect traceability it only contains virgin substances (no recycled

components for which establishing a traceability is impossible)

CLEANDoes not contain solvents adhesives or phthalates and does not generate

toxic emissions

STABLE AND RESISTANTVESTAreg fibres benefit from a thermal treatment which provides hydrophobic properties to the material The

formula reinforced with mineral resin lignin and antioxidants enables a remarkable mechanical resistance as

well as an outstanding design

The mineral pigments also offer a strong resistance to UV rays making the colours more durable whatever the

exposure

SOURCE

Raw material VESTAreg

X-FIRE is highly fire-resistant Wood fibres coming from sustainably managed European forests

Board Production France

COMPOSITIONby Volume 75 wood fibres mineral oil mineral salts mineral pigments

PHYSICAL PROPERTIES

Mass sqm COVER 6 195 kgmsup2 COVER 14 165 kgmsup2

Density 1500 kgm3

Parasite resistance Equivalent to use class 4 No development of fungal rot mosses or mould Insect-resistant including termites

Surface appearance Micro-striated surface splinter free blisters or flakes off Maintenance-free

Scratches resistance Equivalent to natural wood - Brushing possible without discolouration

Thermal inertia Low thermal inertia due to the high wood fibres content

ENVIRONMENTAL PROPERTIES

Recycling 100 recyclable 75 renewable and combustible (75 biomass)

Toxic substances Contains no toxic or dangerous products (according to Reach Regulation EC19072006)

Chemical fire retardant substance None

Solvents None

Heavy metals None lead-and mercury-free stabilization

Phthalates adhesives None

Formaldehydes and VOCs Lower than or equal to natural wood

VESTAreg REINFORCED WOOD FIBER

VESTA X-FIRE

ENVIRONMENTAL PRODUCT DECLARATION

1 - Values describing the environmental impacts

Owner of the declaration NEOLIFE Editor BUREAU VERITAS CODDE Declaration reference DEP_NEOLIFE_COVER_201507

Publication 10072015 Validity 10072020

Complies with the standard ISO 14025 NF EN 15804+A1 And itrsquos national addendum X P01-064CN

Environmental Declaration of the COVER productavailable on request

ENVIRONMENTAL PRODUCT DECLARATION

2 ndash Values describing the use of primary energetic sources other resources and water

3 ndash Complementary values describing the outflows

FURTHER DETAILS

33

TECHNICAL DESCRIPTION

French accreditaion type laquo Avis Technique Expeacuterimental de Type A raquo issued by CSTB (France)

Ndeg2278 ndash Available at httpevaluationcstbfrrechercherproduits-evaluesprestations=atex

VESTA Reinforced Wood Fiber cladding containing at least 75 wood fibres

Boards with a slatted aspect featuring 6 cm or 14 cm ribs

Fire rating with natural mineral salts following EN 13501-12007

COVER 6 B-s3-d0 minimum

COVER 14 B-s3-d0 minimum

Invisible fixing with stainless steel hooks screwed into wood or metal battens

Fast and accurate fitting thanks to the interlocking board system

Outside corners catered for by using 45deg miter cuts or aluminium corner profile

Dimensional stability of maximum 2mm m over ∆80degC

rot-proof not sensitive to moss and mould

Insect-resistant termites included

Stable colors after natural patina is acquired

Contact us to get the full technical specification sheet

CONTACT

CAUTION

This technical sheet is associated with the technical installation guide of CLAD claddingboard available at wwwneolife-solutionscom

NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters

disposal for any clarifications concerning the installation procedure of its products

The specifications and recommendations given in the installation guide are not a

substitute to regulations concerning safety environment and professional regulatory

dispositions

All instructions concerning the installation of our cladding are to be followed

Assembly errors are not covered by the NEOLIFEreg guarantee

An approved fitter shall be able to assess the construction conformity to the local

professional installation guidelines

304 Route Nationale 6 ndash Celtic Parc Bacirctiment Avalon II - 69760 Limonest FranceTel +33 (0)4 78 25 63 08 ndash Fax +33 (0)4 72 29 29 47

wwwneolife-solutionscom

Page 19: COVER 6 & 14 CLADDING · 2020. 11. 3. · 60 cm centre-to-centre spacing 10 / m ... sill and causes stains onto the cladding after raining WINDOW SILL Advice : Make a window sill

DESIGN GUIDELINES

BEST PRACTICEFind all the best practices in the NEOLIFEreg installation guide

available on our website wwwneolife-solutionscom

Closed metal profile at the junction betweencladding render no water runoffpossibility risk of stains and moisture on thestructure no ventilation

Flat window sill without water drop Dust and pollution collects on the windowsill and causes stains onto the cladding afterraining

WINDOW SILL

Advice Make a window sill with a 10 slopeminimum and a water drop with 30 mm gapfrom the cladding

Flat metal window sill

30mm

Advice Use a perforated metal ending profile and raise the cladding boards 5mm above the profile

no ventilation

Visible screwWater storage

Hidden screw

Perforated closure profile ventilation and water runoff

5mm

ENDINGS JUNCTIONS

Absence of water drop Water drop

REMARQUES IMPORTANTES SUR LA POSECAUTION

THE FULL INSTALLATION MANUAL OF COVER CLADDING PANELS IS AVAILABLE AT

wwwneolife-solutionscom

NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters

disposal for any clarifications concerning the installation procedure of its products

The specifications and recommendations given in the installation guide are not a

substitute to regulations concerning safety environment and professional regulatory

dispositions

All instructions concerning the installation of our cladding are to be followed

Assembly errors are not covered by the NEOLIFEreg guarantee

An approved fitter shall be able to assess the construction conformity to the local

professional installation guidelines

MAINTENANCE

21

Depending on the boards dirt after implementation (presence of mud dust etchellip) especially in the

grooves rain stains can appear on the surface

NEOLIFE strongly recommend to clean the boards after implementation with a pressure

washer following the boardsrsquo orientation (distance of min 20cm from the board DO NOT

USE a rotary nozzle)

Recommendations

Do not forget to clean the window shelves as well avoiding so any risk of dust stains on the

cladding after the first rain (windows are frequently dusty during construction)

All metal joineries (windows parapet capping etchellip) have to have a drip-edge flashing in

order to limit the water runoff on the cladding Shop signs or any other elements installed on

the cladding have to be moved forward (space left between cladding and the element) to

avoid any stains

Caution

If any operation involving the use of asphalt or concrete occurs after facade completion

NEOLIFE recommend to protect the cladding with a plastic cover in order to avoid stains

Indeed if not protected a greasy steam can spread on the surface and in the grooves In that

case a grease-removing product will be needed to clean the boards and all the surrounding

elements

BUILDING SITE CLEANING

LONG LASTING

VERY LIMITED MAINTENANCE

The material does not require any wood preservative (oils varnishes saturators hellip)

bull The VESTAreg material is naturally equivalent to use class 4(service environment In contact with ground or fresh water amp Permanently exposed to wetting The use classes rank the risk of exposure to decay and insect attack for differing in service environments according to EN 335 ndash 2)

bull Highly hydrophobic and rot-proof no algae fungi or moss development

bull Insect-resistant does not require any treatments against termites

STAIN REMOVAL

STAINS

Tanin stains

During the first weeks after installation tannin rings may occur because of the rain especially

on claddings with a light colour They will be washed off and fade during the next rain to

lessen until they completely disappear Be careful not to mistake these stains with dust or

pollution stains which appear on all cladding types

Bleach-based cleaning products

Slight discolouration Clean with water and complete if needed with slight brushing in the

boards orientation

Graffities oil paint and ink

Use a specialised stain remover (ex laquo STG 105 BIO raquo de STG)

Bitumen grease

Use a specialised stain remover (ex laquo Scalp Aqua 03 raquo)

Oxidation stains after contact with a corroded metal

Use a specialised wood de-greyer (ex laquo Scalp Neutral DA 66 raquo)

Caution

- Analyse properly the substance to clean so to use the right stain removing product

- Always test the stain removing product on a small and discrete surface before cleaning the

entire board

- It is mandatory that you analyse on a long time scale (and after exposure to Uvs) that the

solution you choose will not react with the cladding and therefore produce unsightly effects

DAMAGES

bull Scratches cigarette marks abrasion Brush away with a brass brush (lengthways)

TECHNICAL CHARACTERISTICS

25

SYSTEM PERFORMANCES

DESIGNATIONTEST

METHODS amp STANDARDS

CLADDING OUTLIFE COVER 6 amp 14

WIND LOAD (Depression) COVER 6 (4 ribs) COVER 14 (2 ribss)

Fixings description Eurocodes EN 1991-1-4 Test results Maximum shearing

pressure Test results Maximum shearingpressure

Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction

4 900 Pa

(degradation)140 kNm2 5 200 Pa

(degradation) 148 kNm2

Maximum 400mm centre-to-centre support spacing with one fixing tab at every junction 8 300 Pa (ruine) 237 kNm2 8 300 Pa (ruine) 237 kNm2

IMPACT RESISTANCE COVER 6 (4 ribs) COVER 14 (2 ribs)

Fixings description NF P 08302 Test results Test results

Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction

No damage with the impact energies below

Soft impacts 50Kg 130J

Soft impacts 3Kg 20J

Hard impacts 1Kg 3J

No damage with the impact energies below Soft impacts 50Kg 130J

Soft impacts 3Kg 20JHard impacts 1Kg 3J

SEISMIC RESISTANCE COVER 6 amp14

COVER 6 amp 14can be installed in seismic zones and buildings according to the following details

Highest seismic behaviour following Eurocode 8 no risk of falling boards or permanent deformations after static and dynamic test

FIRE RESISTANCE COVER 6 COVER 14

Tests description EN 13823 et EN 13501-12007

Fire rating

(on A2-s1d0 wall)

Fire rating

(on A2-s1d0 wall)

SBI test carried out on 3 models forming a 1500mm high 1000mm long and 500mm wide

dihedral wedge Assembly on air board and horizontal wood batten Valable contre un

substrat A2-s1d0

B-s3d0

Equivalent UK class 0

FIGRA average 1151Ws

THR average 6MJ

SMOGRA average 371 m2s2

B-s3d0

Equivalent UK class 0

FIGRA average 1924Ws

THR average 112MJ

SMOGRA average 592m2s2

Horizontal installation Class B-s3 d0 - Vertical installation on metal framework Class B s3 d0 on wooden framework Class C s3 d0 (EN 13501-12007)

PHYSICAL AND MECHANICAL FEATURES

DESIGNATION TEST METHODES amp STANDARDS COVER 6 amp 14 OUTLIFE CLADDING

FLAMMABLE MASS COVER 6 COVER 14Tests description NF EN 13238 Flammable mass per sqm (MJ)Tests realised according to the crucible method on at least 5 product samples 334 MJ 285 MJ

APPEARANCE DURABILITY(ageing under QUV) COVER 6 amp 14

Test descriptionNF EN 927-6 (2006)

FCBA‐ LBO6-PHY‐001

Test results

Artificial ageing test under QUV allowing an assessment of durability and decorative

properties modification Total duration 10 weeks comprising

condensation UV radiation and water spray phases

Stable products according to the EN 927-2

No blistering defects are observed according to ISO 4628-2 standard Resultt 0No cracking defects are observed according to ISO 4628-4 standard Result 0No flaking defects are observed according to ISO 4628-5 standard Result 0

THERMAL EXPANSION COVER 6 amp 14

Test description

ISO 11359-2 adapted to

FCBA - LBO6PHY-001

Test results

Thermodilatometric test in climatic room going from -20deg to +60deg to determine the profils

thermal expansion coefficient in solid state

Coefficient de dilatation thermique moyen

Longitudinally δL = 380 degK-1 10-6 standard spacing 210 degK-1 10-6 For uninstalled boardsTransversally δB = 575 degK-1 10-6 standard spacing 211 degK-1 10-6 For uninstalled boards

WATER UPTAKE DETERMINATION COVER 6 amp 14

Test description FCBA‐LBO‐MECA‐014 Test results

Water uptake determination after immersion in cold water during 28 days Measure of the

mass in its initial state and after 124714 et 28 days

Boards suitable to use in class 4 (Wood use class NF EN 335-2)Boards naturally resistant against fungus and soft rotAverage water uptake after 28 days 803Water content at 28 days and imputed to the cellulosic matter 143

ELASTICITY CONSTRAINS AND MODULE IN FLEXION COVER 6 amp 14

Test description

FCBA‐LBO‐MECA‐008

NF EN 310 modifiedWPC profiles

Test results

3 point flexion under normal conditions 20degCand 65 RH

Eaverage = 904 Nmm2fm = 40 Nmm2

ENVIRONMENTAL CHARACTERISTICS

28

VESTAreg ECO-MATERIAL

VESTAreg (Vegetal Ecological Stable Timber

Advantage) is an innovative and eco-friendly compound

with exceptional properties It was developed by

NEOCOreg NEOLIFEreglsquos Research Centre specialising in

green technologies in partnership with European experts

EXCEPTIONAL WOOD FIBER CONTENTVESTAreg revolutionises eco-materials and the design of

environmental solutions for construction projects and the

landscaping of outside spaces It finally brings a response

to the architects landscapers and design officesrsquo

demands working on eco-construction and sustainable

development projects

ECO-FRIENDLYThe wood fibres contained in VESTAreg come exclusively

from sawmills offcuts the wood coming from sustainably

managed European forests The production of our material

does not require the cutting of any trees and does not use treated wood from recycled pallets Moreover

NEOLIFE does not use any toxic additives in the production process of the material

VESTAreg is 100 recyclable with a perfect traceability it only contains virgin substances (no recycled

components for which establishing a traceability is impossible)

CLEANDoes not contain solvents adhesives or phthalates and does not generate

toxic emissions

STABLE AND RESISTANTVESTAreg fibres benefit from a thermal treatment which provides hydrophobic properties to the material The

formula reinforced with mineral resin lignin and antioxidants enables a remarkable mechanical resistance as

well as an outstanding design

The mineral pigments also offer a strong resistance to UV rays making the colours more durable whatever the

exposure

SOURCE

Raw material VESTAreg

X-FIRE is highly fire-resistant Wood fibres coming from sustainably managed European forests

Board Production France

COMPOSITIONby Volume 75 wood fibres mineral oil mineral salts mineral pigments

PHYSICAL PROPERTIES

Mass sqm COVER 6 195 kgmsup2 COVER 14 165 kgmsup2

Density 1500 kgm3

Parasite resistance Equivalent to use class 4 No development of fungal rot mosses or mould Insect-resistant including termites

Surface appearance Micro-striated surface splinter free blisters or flakes off Maintenance-free

Scratches resistance Equivalent to natural wood - Brushing possible without discolouration

Thermal inertia Low thermal inertia due to the high wood fibres content

ENVIRONMENTAL PROPERTIES

Recycling 100 recyclable 75 renewable and combustible (75 biomass)

Toxic substances Contains no toxic or dangerous products (according to Reach Regulation EC19072006)

Chemical fire retardant substance None

Solvents None

Heavy metals None lead-and mercury-free stabilization

Phthalates adhesives None

Formaldehydes and VOCs Lower than or equal to natural wood

VESTAreg REINFORCED WOOD FIBER

VESTA X-FIRE

ENVIRONMENTAL PRODUCT DECLARATION

1 - Values describing the environmental impacts

Owner of the declaration NEOLIFE Editor BUREAU VERITAS CODDE Declaration reference DEP_NEOLIFE_COVER_201507

Publication 10072015 Validity 10072020

Complies with the standard ISO 14025 NF EN 15804+A1 And itrsquos national addendum X P01-064CN

Environmental Declaration of the COVER productavailable on request

ENVIRONMENTAL PRODUCT DECLARATION

2 ndash Values describing the use of primary energetic sources other resources and water

3 ndash Complementary values describing the outflows

FURTHER DETAILS

33

TECHNICAL DESCRIPTION

French accreditaion type laquo Avis Technique Expeacuterimental de Type A raquo issued by CSTB (France)

Ndeg2278 ndash Available at httpevaluationcstbfrrechercherproduits-evaluesprestations=atex

VESTA Reinforced Wood Fiber cladding containing at least 75 wood fibres

Boards with a slatted aspect featuring 6 cm or 14 cm ribs

Fire rating with natural mineral salts following EN 13501-12007

COVER 6 B-s3-d0 minimum

COVER 14 B-s3-d0 minimum

Invisible fixing with stainless steel hooks screwed into wood or metal battens

Fast and accurate fitting thanks to the interlocking board system

Outside corners catered for by using 45deg miter cuts or aluminium corner profile

Dimensional stability of maximum 2mm m over ∆80degC

rot-proof not sensitive to moss and mould

Insect-resistant termites included

Stable colors after natural patina is acquired

Contact us to get the full technical specification sheet

CONTACT

CAUTION

This technical sheet is associated with the technical installation guide of CLAD claddingboard available at wwwneolife-solutionscom

NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters

disposal for any clarifications concerning the installation procedure of its products

The specifications and recommendations given in the installation guide are not a

substitute to regulations concerning safety environment and professional regulatory

dispositions

All instructions concerning the installation of our cladding are to be followed

Assembly errors are not covered by the NEOLIFEreg guarantee

An approved fitter shall be able to assess the construction conformity to the local

professional installation guidelines

304 Route Nationale 6 ndash Celtic Parc Bacirctiment Avalon II - 69760 Limonest FranceTel +33 (0)4 78 25 63 08 ndash Fax +33 (0)4 72 29 29 47

wwwneolife-solutionscom

Page 20: COVER 6 & 14 CLADDING · 2020. 11. 3. · 60 cm centre-to-centre spacing 10 / m ... sill and causes stains onto the cladding after raining WINDOW SILL Advice : Make a window sill

REMARQUES IMPORTANTES SUR LA POSECAUTION

THE FULL INSTALLATION MANUAL OF COVER CLADDING PANELS IS AVAILABLE AT

wwwneolife-solutionscom

NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters

disposal for any clarifications concerning the installation procedure of its products

The specifications and recommendations given in the installation guide are not a

substitute to regulations concerning safety environment and professional regulatory

dispositions

All instructions concerning the installation of our cladding are to be followed

Assembly errors are not covered by the NEOLIFEreg guarantee

An approved fitter shall be able to assess the construction conformity to the local

professional installation guidelines

MAINTENANCE

21

Depending on the boards dirt after implementation (presence of mud dust etchellip) especially in the

grooves rain stains can appear on the surface

NEOLIFE strongly recommend to clean the boards after implementation with a pressure

washer following the boardsrsquo orientation (distance of min 20cm from the board DO NOT

USE a rotary nozzle)

Recommendations

Do not forget to clean the window shelves as well avoiding so any risk of dust stains on the

cladding after the first rain (windows are frequently dusty during construction)

All metal joineries (windows parapet capping etchellip) have to have a drip-edge flashing in

order to limit the water runoff on the cladding Shop signs or any other elements installed on

the cladding have to be moved forward (space left between cladding and the element) to

avoid any stains

Caution

If any operation involving the use of asphalt or concrete occurs after facade completion

NEOLIFE recommend to protect the cladding with a plastic cover in order to avoid stains

Indeed if not protected a greasy steam can spread on the surface and in the grooves In that

case a grease-removing product will be needed to clean the boards and all the surrounding

elements

BUILDING SITE CLEANING

LONG LASTING

VERY LIMITED MAINTENANCE

The material does not require any wood preservative (oils varnishes saturators hellip)

bull The VESTAreg material is naturally equivalent to use class 4(service environment In contact with ground or fresh water amp Permanently exposed to wetting The use classes rank the risk of exposure to decay and insect attack for differing in service environments according to EN 335 ndash 2)

bull Highly hydrophobic and rot-proof no algae fungi or moss development

bull Insect-resistant does not require any treatments against termites

STAIN REMOVAL

STAINS

Tanin stains

During the first weeks after installation tannin rings may occur because of the rain especially

on claddings with a light colour They will be washed off and fade during the next rain to

lessen until they completely disappear Be careful not to mistake these stains with dust or

pollution stains which appear on all cladding types

Bleach-based cleaning products

Slight discolouration Clean with water and complete if needed with slight brushing in the

boards orientation

Graffities oil paint and ink

Use a specialised stain remover (ex laquo STG 105 BIO raquo de STG)

Bitumen grease

Use a specialised stain remover (ex laquo Scalp Aqua 03 raquo)

Oxidation stains after contact with a corroded metal

Use a specialised wood de-greyer (ex laquo Scalp Neutral DA 66 raquo)

Caution

- Analyse properly the substance to clean so to use the right stain removing product

- Always test the stain removing product on a small and discrete surface before cleaning the

entire board

- It is mandatory that you analyse on a long time scale (and after exposure to Uvs) that the

solution you choose will not react with the cladding and therefore produce unsightly effects

DAMAGES

bull Scratches cigarette marks abrasion Brush away with a brass brush (lengthways)

TECHNICAL CHARACTERISTICS

25

SYSTEM PERFORMANCES

DESIGNATIONTEST

METHODS amp STANDARDS

CLADDING OUTLIFE COVER 6 amp 14

WIND LOAD (Depression) COVER 6 (4 ribs) COVER 14 (2 ribss)

Fixings description Eurocodes EN 1991-1-4 Test results Maximum shearing

pressure Test results Maximum shearingpressure

Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction

4 900 Pa

(degradation)140 kNm2 5 200 Pa

(degradation) 148 kNm2

Maximum 400mm centre-to-centre support spacing with one fixing tab at every junction 8 300 Pa (ruine) 237 kNm2 8 300 Pa (ruine) 237 kNm2

IMPACT RESISTANCE COVER 6 (4 ribs) COVER 14 (2 ribs)

Fixings description NF P 08302 Test results Test results

Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction

No damage with the impact energies below

Soft impacts 50Kg 130J

Soft impacts 3Kg 20J

Hard impacts 1Kg 3J

No damage with the impact energies below Soft impacts 50Kg 130J

Soft impacts 3Kg 20JHard impacts 1Kg 3J

SEISMIC RESISTANCE COVER 6 amp14

COVER 6 amp 14can be installed in seismic zones and buildings according to the following details

Highest seismic behaviour following Eurocode 8 no risk of falling boards or permanent deformations after static and dynamic test

FIRE RESISTANCE COVER 6 COVER 14

Tests description EN 13823 et EN 13501-12007

Fire rating

(on A2-s1d0 wall)

Fire rating

(on A2-s1d0 wall)

SBI test carried out on 3 models forming a 1500mm high 1000mm long and 500mm wide

dihedral wedge Assembly on air board and horizontal wood batten Valable contre un

substrat A2-s1d0

B-s3d0

Equivalent UK class 0

FIGRA average 1151Ws

THR average 6MJ

SMOGRA average 371 m2s2

B-s3d0

Equivalent UK class 0

FIGRA average 1924Ws

THR average 112MJ

SMOGRA average 592m2s2

Horizontal installation Class B-s3 d0 - Vertical installation on metal framework Class B s3 d0 on wooden framework Class C s3 d0 (EN 13501-12007)

PHYSICAL AND MECHANICAL FEATURES

DESIGNATION TEST METHODES amp STANDARDS COVER 6 amp 14 OUTLIFE CLADDING

FLAMMABLE MASS COVER 6 COVER 14Tests description NF EN 13238 Flammable mass per sqm (MJ)Tests realised according to the crucible method on at least 5 product samples 334 MJ 285 MJ

APPEARANCE DURABILITY(ageing under QUV) COVER 6 amp 14

Test descriptionNF EN 927-6 (2006)

FCBA‐ LBO6-PHY‐001

Test results

Artificial ageing test under QUV allowing an assessment of durability and decorative

properties modification Total duration 10 weeks comprising

condensation UV radiation and water spray phases

Stable products according to the EN 927-2

No blistering defects are observed according to ISO 4628-2 standard Resultt 0No cracking defects are observed according to ISO 4628-4 standard Result 0No flaking defects are observed according to ISO 4628-5 standard Result 0

THERMAL EXPANSION COVER 6 amp 14

Test description

ISO 11359-2 adapted to

FCBA - LBO6PHY-001

Test results

Thermodilatometric test in climatic room going from -20deg to +60deg to determine the profils

thermal expansion coefficient in solid state

Coefficient de dilatation thermique moyen

Longitudinally δL = 380 degK-1 10-6 standard spacing 210 degK-1 10-6 For uninstalled boardsTransversally δB = 575 degK-1 10-6 standard spacing 211 degK-1 10-6 For uninstalled boards

WATER UPTAKE DETERMINATION COVER 6 amp 14

Test description FCBA‐LBO‐MECA‐014 Test results

Water uptake determination after immersion in cold water during 28 days Measure of the

mass in its initial state and after 124714 et 28 days

Boards suitable to use in class 4 (Wood use class NF EN 335-2)Boards naturally resistant against fungus and soft rotAverage water uptake after 28 days 803Water content at 28 days and imputed to the cellulosic matter 143

ELASTICITY CONSTRAINS AND MODULE IN FLEXION COVER 6 amp 14

Test description

FCBA‐LBO‐MECA‐008

NF EN 310 modifiedWPC profiles

Test results

3 point flexion under normal conditions 20degCand 65 RH

Eaverage = 904 Nmm2fm = 40 Nmm2

ENVIRONMENTAL CHARACTERISTICS

28

VESTAreg ECO-MATERIAL

VESTAreg (Vegetal Ecological Stable Timber

Advantage) is an innovative and eco-friendly compound

with exceptional properties It was developed by

NEOCOreg NEOLIFEreglsquos Research Centre specialising in

green technologies in partnership with European experts

EXCEPTIONAL WOOD FIBER CONTENTVESTAreg revolutionises eco-materials and the design of

environmental solutions for construction projects and the

landscaping of outside spaces It finally brings a response

to the architects landscapers and design officesrsquo

demands working on eco-construction and sustainable

development projects

ECO-FRIENDLYThe wood fibres contained in VESTAreg come exclusively

from sawmills offcuts the wood coming from sustainably

managed European forests The production of our material

does not require the cutting of any trees and does not use treated wood from recycled pallets Moreover

NEOLIFE does not use any toxic additives in the production process of the material

VESTAreg is 100 recyclable with a perfect traceability it only contains virgin substances (no recycled

components for which establishing a traceability is impossible)

CLEANDoes not contain solvents adhesives or phthalates and does not generate

toxic emissions

STABLE AND RESISTANTVESTAreg fibres benefit from a thermal treatment which provides hydrophobic properties to the material The

formula reinforced with mineral resin lignin and antioxidants enables a remarkable mechanical resistance as

well as an outstanding design

The mineral pigments also offer a strong resistance to UV rays making the colours more durable whatever the

exposure

SOURCE

Raw material VESTAreg

X-FIRE is highly fire-resistant Wood fibres coming from sustainably managed European forests

Board Production France

COMPOSITIONby Volume 75 wood fibres mineral oil mineral salts mineral pigments

PHYSICAL PROPERTIES

Mass sqm COVER 6 195 kgmsup2 COVER 14 165 kgmsup2

Density 1500 kgm3

Parasite resistance Equivalent to use class 4 No development of fungal rot mosses or mould Insect-resistant including termites

Surface appearance Micro-striated surface splinter free blisters or flakes off Maintenance-free

Scratches resistance Equivalent to natural wood - Brushing possible without discolouration

Thermal inertia Low thermal inertia due to the high wood fibres content

ENVIRONMENTAL PROPERTIES

Recycling 100 recyclable 75 renewable and combustible (75 biomass)

Toxic substances Contains no toxic or dangerous products (according to Reach Regulation EC19072006)

Chemical fire retardant substance None

Solvents None

Heavy metals None lead-and mercury-free stabilization

Phthalates adhesives None

Formaldehydes and VOCs Lower than or equal to natural wood

VESTAreg REINFORCED WOOD FIBER

VESTA X-FIRE

ENVIRONMENTAL PRODUCT DECLARATION

1 - Values describing the environmental impacts

Owner of the declaration NEOLIFE Editor BUREAU VERITAS CODDE Declaration reference DEP_NEOLIFE_COVER_201507

Publication 10072015 Validity 10072020

Complies with the standard ISO 14025 NF EN 15804+A1 And itrsquos national addendum X P01-064CN

Environmental Declaration of the COVER productavailable on request

ENVIRONMENTAL PRODUCT DECLARATION

2 ndash Values describing the use of primary energetic sources other resources and water

3 ndash Complementary values describing the outflows

FURTHER DETAILS

33

TECHNICAL DESCRIPTION

French accreditaion type laquo Avis Technique Expeacuterimental de Type A raquo issued by CSTB (France)

Ndeg2278 ndash Available at httpevaluationcstbfrrechercherproduits-evaluesprestations=atex

VESTA Reinforced Wood Fiber cladding containing at least 75 wood fibres

Boards with a slatted aspect featuring 6 cm or 14 cm ribs

Fire rating with natural mineral salts following EN 13501-12007

COVER 6 B-s3-d0 minimum

COVER 14 B-s3-d0 minimum

Invisible fixing with stainless steel hooks screwed into wood or metal battens

Fast and accurate fitting thanks to the interlocking board system

Outside corners catered for by using 45deg miter cuts or aluminium corner profile

Dimensional stability of maximum 2mm m over ∆80degC

rot-proof not sensitive to moss and mould

Insect-resistant termites included

Stable colors after natural patina is acquired

Contact us to get the full technical specification sheet

CONTACT

CAUTION

This technical sheet is associated with the technical installation guide of CLAD claddingboard available at wwwneolife-solutionscom

NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters

disposal for any clarifications concerning the installation procedure of its products

The specifications and recommendations given in the installation guide are not a

substitute to regulations concerning safety environment and professional regulatory

dispositions

All instructions concerning the installation of our cladding are to be followed

Assembly errors are not covered by the NEOLIFEreg guarantee

An approved fitter shall be able to assess the construction conformity to the local

professional installation guidelines

304 Route Nationale 6 ndash Celtic Parc Bacirctiment Avalon II - 69760 Limonest FranceTel +33 (0)4 78 25 63 08 ndash Fax +33 (0)4 72 29 29 47

wwwneolife-solutionscom

Page 21: COVER 6 & 14 CLADDING · 2020. 11. 3. · 60 cm centre-to-centre spacing 10 / m ... sill and causes stains onto the cladding after raining WINDOW SILL Advice : Make a window sill

MAINTENANCE

21

Depending on the boards dirt after implementation (presence of mud dust etchellip) especially in the

grooves rain stains can appear on the surface

NEOLIFE strongly recommend to clean the boards after implementation with a pressure

washer following the boardsrsquo orientation (distance of min 20cm from the board DO NOT

USE a rotary nozzle)

Recommendations

Do not forget to clean the window shelves as well avoiding so any risk of dust stains on the

cladding after the first rain (windows are frequently dusty during construction)

All metal joineries (windows parapet capping etchellip) have to have a drip-edge flashing in

order to limit the water runoff on the cladding Shop signs or any other elements installed on

the cladding have to be moved forward (space left between cladding and the element) to

avoid any stains

Caution

If any operation involving the use of asphalt or concrete occurs after facade completion

NEOLIFE recommend to protect the cladding with a plastic cover in order to avoid stains

Indeed if not protected a greasy steam can spread on the surface and in the grooves In that

case a grease-removing product will be needed to clean the boards and all the surrounding

elements

BUILDING SITE CLEANING

LONG LASTING

VERY LIMITED MAINTENANCE

The material does not require any wood preservative (oils varnishes saturators hellip)

bull The VESTAreg material is naturally equivalent to use class 4(service environment In contact with ground or fresh water amp Permanently exposed to wetting The use classes rank the risk of exposure to decay and insect attack for differing in service environments according to EN 335 ndash 2)

bull Highly hydrophobic and rot-proof no algae fungi or moss development

bull Insect-resistant does not require any treatments against termites

STAIN REMOVAL

STAINS

Tanin stains

During the first weeks after installation tannin rings may occur because of the rain especially

on claddings with a light colour They will be washed off and fade during the next rain to

lessen until they completely disappear Be careful not to mistake these stains with dust or

pollution stains which appear on all cladding types

Bleach-based cleaning products

Slight discolouration Clean with water and complete if needed with slight brushing in the

boards orientation

Graffities oil paint and ink

Use a specialised stain remover (ex laquo STG 105 BIO raquo de STG)

Bitumen grease

Use a specialised stain remover (ex laquo Scalp Aqua 03 raquo)

Oxidation stains after contact with a corroded metal

Use a specialised wood de-greyer (ex laquo Scalp Neutral DA 66 raquo)

Caution

- Analyse properly the substance to clean so to use the right stain removing product

- Always test the stain removing product on a small and discrete surface before cleaning the

entire board

- It is mandatory that you analyse on a long time scale (and after exposure to Uvs) that the

solution you choose will not react with the cladding and therefore produce unsightly effects

DAMAGES

bull Scratches cigarette marks abrasion Brush away with a brass brush (lengthways)

TECHNICAL CHARACTERISTICS

25

SYSTEM PERFORMANCES

DESIGNATIONTEST

METHODS amp STANDARDS

CLADDING OUTLIFE COVER 6 amp 14

WIND LOAD (Depression) COVER 6 (4 ribs) COVER 14 (2 ribss)

Fixings description Eurocodes EN 1991-1-4 Test results Maximum shearing

pressure Test results Maximum shearingpressure

Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction

4 900 Pa

(degradation)140 kNm2 5 200 Pa

(degradation) 148 kNm2

Maximum 400mm centre-to-centre support spacing with one fixing tab at every junction 8 300 Pa (ruine) 237 kNm2 8 300 Pa (ruine) 237 kNm2

IMPACT RESISTANCE COVER 6 (4 ribs) COVER 14 (2 ribs)

Fixings description NF P 08302 Test results Test results

Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction

No damage with the impact energies below

Soft impacts 50Kg 130J

Soft impacts 3Kg 20J

Hard impacts 1Kg 3J

No damage with the impact energies below Soft impacts 50Kg 130J

Soft impacts 3Kg 20JHard impacts 1Kg 3J

SEISMIC RESISTANCE COVER 6 amp14

COVER 6 amp 14can be installed in seismic zones and buildings according to the following details

Highest seismic behaviour following Eurocode 8 no risk of falling boards or permanent deformations after static and dynamic test

FIRE RESISTANCE COVER 6 COVER 14

Tests description EN 13823 et EN 13501-12007

Fire rating

(on A2-s1d0 wall)

Fire rating

(on A2-s1d0 wall)

SBI test carried out on 3 models forming a 1500mm high 1000mm long and 500mm wide

dihedral wedge Assembly on air board and horizontal wood batten Valable contre un

substrat A2-s1d0

B-s3d0

Equivalent UK class 0

FIGRA average 1151Ws

THR average 6MJ

SMOGRA average 371 m2s2

B-s3d0

Equivalent UK class 0

FIGRA average 1924Ws

THR average 112MJ

SMOGRA average 592m2s2

Horizontal installation Class B-s3 d0 - Vertical installation on metal framework Class B s3 d0 on wooden framework Class C s3 d0 (EN 13501-12007)

PHYSICAL AND MECHANICAL FEATURES

DESIGNATION TEST METHODES amp STANDARDS COVER 6 amp 14 OUTLIFE CLADDING

FLAMMABLE MASS COVER 6 COVER 14Tests description NF EN 13238 Flammable mass per sqm (MJ)Tests realised according to the crucible method on at least 5 product samples 334 MJ 285 MJ

APPEARANCE DURABILITY(ageing under QUV) COVER 6 amp 14

Test descriptionNF EN 927-6 (2006)

FCBA‐ LBO6-PHY‐001

Test results

Artificial ageing test under QUV allowing an assessment of durability and decorative

properties modification Total duration 10 weeks comprising

condensation UV radiation and water spray phases

Stable products according to the EN 927-2

No blistering defects are observed according to ISO 4628-2 standard Resultt 0No cracking defects are observed according to ISO 4628-4 standard Result 0No flaking defects are observed according to ISO 4628-5 standard Result 0

THERMAL EXPANSION COVER 6 amp 14

Test description

ISO 11359-2 adapted to

FCBA - LBO6PHY-001

Test results

Thermodilatometric test in climatic room going from -20deg to +60deg to determine the profils

thermal expansion coefficient in solid state

Coefficient de dilatation thermique moyen

Longitudinally δL = 380 degK-1 10-6 standard spacing 210 degK-1 10-6 For uninstalled boardsTransversally δB = 575 degK-1 10-6 standard spacing 211 degK-1 10-6 For uninstalled boards

WATER UPTAKE DETERMINATION COVER 6 amp 14

Test description FCBA‐LBO‐MECA‐014 Test results

Water uptake determination after immersion in cold water during 28 days Measure of the

mass in its initial state and after 124714 et 28 days

Boards suitable to use in class 4 (Wood use class NF EN 335-2)Boards naturally resistant against fungus and soft rotAverage water uptake after 28 days 803Water content at 28 days and imputed to the cellulosic matter 143

ELASTICITY CONSTRAINS AND MODULE IN FLEXION COVER 6 amp 14

Test description

FCBA‐LBO‐MECA‐008

NF EN 310 modifiedWPC profiles

Test results

3 point flexion under normal conditions 20degCand 65 RH

Eaverage = 904 Nmm2fm = 40 Nmm2

ENVIRONMENTAL CHARACTERISTICS

28

VESTAreg ECO-MATERIAL

VESTAreg (Vegetal Ecological Stable Timber

Advantage) is an innovative and eco-friendly compound

with exceptional properties It was developed by

NEOCOreg NEOLIFEreglsquos Research Centre specialising in

green technologies in partnership with European experts

EXCEPTIONAL WOOD FIBER CONTENTVESTAreg revolutionises eco-materials and the design of

environmental solutions for construction projects and the

landscaping of outside spaces It finally brings a response

to the architects landscapers and design officesrsquo

demands working on eco-construction and sustainable

development projects

ECO-FRIENDLYThe wood fibres contained in VESTAreg come exclusively

from sawmills offcuts the wood coming from sustainably

managed European forests The production of our material

does not require the cutting of any trees and does not use treated wood from recycled pallets Moreover

NEOLIFE does not use any toxic additives in the production process of the material

VESTAreg is 100 recyclable with a perfect traceability it only contains virgin substances (no recycled

components for which establishing a traceability is impossible)

CLEANDoes not contain solvents adhesives or phthalates and does not generate

toxic emissions

STABLE AND RESISTANTVESTAreg fibres benefit from a thermal treatment which provides hydrophobic properties to the material The

formula reinforced with mineral resin lignin and antioxidants enables a remarkable mechanical resistance as

well as an outstanding design

The mineral pigments also offer a strong resistance to UV rays making the colours more durable whatever the

exposure

SOURCE

Raw material VESTAreg

X-FIRE is highly fire-resistant Wood fibres coming from sustainably managed European forests

Board Production France

COMPOSITIONby Volume 75 wood fibres mineral oil mineral salts mineral pigments

PHYSICAL PROPERTIES

Mass sqm COVER 6 195 kgmsup2 COVER 14 165 kgmsup2

Density 1500 kgm3

Parasite resistance Equivalent to use class 4 No development of fungal rot mosses or mould Insect-resistant including termites

Surface appearance Micro-striated surface splinter free blisters or flakes off Maintenance-free

Scratches resistance Equivalent to natural wood - Brushing possible without discolouration

Thermal inertia Low thermal inertia due to the high wood fibres content

ENVIRONMENTAL PROPERTIES

Recycling 100 recyclable 75 renewable and combustible (75 biomass)

Toxic substances Contains no toxic or dangerous products (according to Reach Regulation EC19072006)

Chemical fire retardant substance None

Solvents None

Heavy metals None lead-and mercury-free stabilization

Phthalates adhesives None

Formaldehydes and VOCs Lower than or equal to natural wood

VESTAreg REINFORCED WOOD FIBER

VESTA X-FIRE

ENVIRONMENTAL PRODUCT DECLARATION

1 - Values describing the environmental impacts

Owner of the declaration NEOLIFE Editor BUREAU VERITAS CODDE Declaration reference DEP_NEOLIFE_COVER_201507

Publication 10072015 Validity 10072020

Complies with the standard ISO 14025 NF EN 15804+A1 And itrsquos national addendum X P01-064CN

Environmental Declaration of the COVER productavailable on request

ENVIRONMENTAL PRODUCT DECLARATION

2 ndash Values describing the use of primary energetic sources other resources and water

3 ndash Complementary values describing the outflows

FURTHER DETAILS

33

TECHNICAL DESCRIPTION

French accreditaion type laquo Avis Technique Expeacuterimental de Type A raquo issued by CSTB (France)

Ndeg2278 ndash Available at httpevaluationcstbfrrechercherproduits-evaluesprestations=atex

VESTA Reinforced Wood Fiber cladding containing at least 75 wood fibres

Boards with a slatted aspect featuring 6 cm or 14 cm ribs

Fire rating with natural mineral salts following EN 13501-12007

COVER 6 B-s3-d0 minimum

COVER 14 B-s3-d0 minimum

Invisible fixing with stainless steel hooks screwed into wood or metal battens

Fast and accurate fitting thanks to the interlocking board system

Outside corners catered for by using 45deg miter cuts or aluminium corner profile

Dimensional stability of maximum 2mm m over ∆80degC

rot-proof not sensitive to moss and mould

Insect-resistant termites included

Stable colors after natural patina is acquired

Contact us to get the full technical specification sheet

CONTACT

CAUTION

This technical sheet is associated with the technical installation guide of CLAD claddingboard available at wwwneolife-solutionscom

NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters

disposal for any clarifications concerning the installation procedure of its products

The specifications and recommendations given in the installation guide are not a

substitute to regulations concerning safety environment and professional regulatory

dispositions

All instructions concerning the installation of our cladding are to be followed

Assembly errors are not covered by the NEOLIFEreg guarantee

An approved fitter shall be able to assess the construction conformity to the local

professional installation guidelines

304 Route Nationale 6 ndash Celtic Parc Bacirctiment Avalon II - 69760 Limonest FranceTel +33 (0)4 78 25 63 08 ndash Fax +33 (0)4 72 29 29 47

wwwneolife-solutionscom

Page 22: COVER 6 & 14 CLADDING · 2020. 11. 3. · 60 cm centre-to-centre spacing 10 / m ... sill and causes stains onto the cladding after raining WINDOW SILL Advice : Make a window sill

Depending on the boards dirt after implementation (presence of mud dust etchellip) especially in the

grooves rain stains can appear on the surface

NEOLIFE strongly recommend to clean the boards after implementation with a pressure

washer following the boardsrsquo orientation (distance of min 20cm from the board DO NOT

USE a rotary nozzle)

Recommendations

Do not forget to clean the window shelves as well avoiding so any risk of dust stains on the

cladding after the first rain (windows are frequently dusty during construction)

All metal joineries (windows parapet capping etchellip) have to have a drip-edge flashing in

order to limit the water runoff on the cladding Shop signs or any other elements installed on

the cladding have to be moved forward (space left between cladding and the element) to

avoid any stains

Caution

If any operation involving the use of asphalt or concrete occurs after facade completion

NEOLIFE recommend to protect the cladding with a plastic cover in order to avoid stains

Indeed if not protected a greasy steam can spread on the surface and in the grooves In that

case a grease-removing product will be needed to clean the boards and all the surrounding

elements

BUILDING SITE CLEANING

LONG LASTING

VERY LIMITED MAINTENANCE

The material does not require any wood preservative (oils varnishes saturators hellip)

bull The VESTAreg material is naturally equivalent to use class 4(service environment In contact with ground or fresh water amp Permanently exposed to wetting The use classes rank the risk of exposure to decay and insect attack for differing in service environments according to EN 335 ndash 2)

bull Highly hydrophobic and rot-proof no algae fungi or moss development

bull Insect-resistant does not require any treatments against termites

STAIN REMOVAL

STAINS

Tanin stains

During the first weeks after installation tannin rings may occur because of the rain especially

on claddings with a light colour They will be washed off and fade during the next rain to

lessen until they completely disappear Be careful not to mistake these stains with dust or

pollution stains which appear on all cladding types

Bleach-based cleaning products

Slight discolouration Clean with water and complete if needed with slight brushing in the

boards orientation

Graffities oil paint and ink

Use a specialised stain remover (ex laquo STG 105 BIO raquo de STG)

Bitumen grease

Use a specialised stain remover (ex laquo Scalp Aqua 03 raquo)

Oxidation stains after contact with a corroded metal

Use a specialised wood de-greyer (ex laquo Scalp Neutral DA 66 raquo)

Caution

- Analyse properly the substance to clean so to use the right stain removing product

- Always test the stain removing product on a small and discrete surface before cleaning the

entire board

- It is mandatory that you analyse on a long time scale (and after exposure to Uvs) that the

solution you choose will not react with the cladding and therefore produce unsightly effects

DAMAGES

bull Scratches cigarette marks abrasion Brush away with a brass brush (lengthways)

TECHNICAL CHARACTERISTICS

25

SYSTEM PERFORMANCES

DESIGNATIONTEST

METHODS amp STANDARDS

CLADDING OUTLIFE COVER 6 amp 14

WIND LOAD (Depression) COVER 6 (4 ribs) COVER 14 (2 ribss)

Fixings description Eurocodes EN 1991-1-4 Test results Maximum shearing

pressure Test results Maximum shearingpressure

Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction

4 900 Pa

(degradation)140 kNm2 5 200 Pa

(degradation) 148 kNm2

Maximum 400mm centre-to-centre support spacing with one fixing tab at every junction 8 300 Pa (ruine) 237 kNm2 8 300 Pa (ruine) 237 kNm2

IMPACT RESISTANCE COVER 6 (4 ribs) COVER 14 (2 ribs)

Fixings description NF P 08302 Test results Test results

Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction

No damage with the impact energies below

Soft impacts 50Kg 130J

Soft impacts 3Kg 20J

Hard impacts 1Kg 3J

No damage with the impact energies below Soft impacts 50Kg 130J

Soft impacts 3Kg 20JHard impacts 1Kg 3J

SEISMIC RESISTANCE COVER 6 amp14

COVER 6 amp 14can be installed in seismic zones and buildings according to the following details

Highest seismic behaviour following Eurocode 8 no risk of falling boards or permanent deformations after static and dynamic test

FIRE RESISTANCE COVER 6 COVER 14

Tests description EN 13823 et EN 13501-12007

Fire rating

(on A2-s1d0 wall)

Fire rating

(on A2-s1d0 wall)

SBI test carried out on 3 models forming a 1500mm high 1000mm long and 500mm wide

dihedral wedge Assembly on air board and horizontal wood batten Valable contre un

substrat A2-s1d0

B-s3d0

Equivalent UK class 0

FIGRA average 1151Ws

THR average 6MJ

SMOGRA average 371 m2s2

B-s3d0

Equivalent UK class 0

FIGRA average 1924Ws

THR average 112MJ

SMOGRA average 592m2s2

Horizontal installation Class B-s3 d0 - Vertical installation on metal framework Class B s3 d0 on wooden framework Class C s3 d0 (EN 13501-12007)

PHYSICAL AND MECHANICAL FEATURES

DESIGNATION TEST METHODES amp STANDARDS COVER 6 amp 14 OUTLIFE CLADDING

FLAMMABLE MASS COVER 6 COVER 14Tests description NF EN 13238 Flammable mass per sqm (MJ)Tests realised according to the crucible method on at least 5 product samples 334 MJ 285 MJ

APPEARANCE DURABILITY(ageing under QUV) COVER 6 amp 14

Test descriptionNF EN 927-6 (2006)

FCBA‐ LBO6-PHY‐001

Test results

Artificial ageing test under QUV allowing an assessment of durability and decorative

properties modification Total duration 10 weeks comprising

condensation UV radiation and water spray phases

Stable products according to the EN 927-2

No blistering defects are observed according to ISO 4628-2 standard Resultt 0No cracking defects are observed according to ISO 4628-4 standard Result 0No flaking defects are observed according to ISO 4628-5 standard Result 0

THERMAL EXPANSION COVER 6 amp 14

Test description

ISO 11359-2 adapted to

FCBA - LBO6PHY-001

Test results

Thermodilatometric test in climatic room going from -20deg to +60deg to determine the profils

thermal expansion coefficient in solid state

Coefficient de dilatation thermique moyen

Longitudinally δL = 380 degK-1 10-6 standard spacing 210 degK-1 10-6 For uninstalled boardsTransversally δB = 575 degK-1 10-6 standard spacing 211 degK-1 10-6 For uninstalled boards

WATER UPTAKE DETERMINATION COVER 6 amp 14

Test description FCBA‐LBO‐MECA‐014 Test results

Water uptake determination after immersion in cold water during 28 days Measure of the

mass in its initial state and after 124714 et 28 days

Boards suitable to use in class 4 (Wood use class NF EN 335-2)Boards naturally resistant against fungus and soft rotAverage water uptake after 28 days 803Water content at 28 days and imputed to the cellulosic matter 143

ELASTICITY CONSTRAINS AND MODULE IN FLEXION COVER 6 amp 14

Test description

FCBA‐LBO‐MECA‐008

NF EN 310 modifiedWPC profiles

Test results

3 point flexion under normal conditions 20degCand 65 RH

Eaverage = 904 Nmm2fm = 40 Nmm2

ENVIRONMENTAL CHARACTERISTICS

28

VESTAreg ECO-MATERIAL

VESTAreg (Vegetal Ecological Stable Timber

Advantage) is an innovative and eco-friendly compound

with exceptional properties It was developed by

NEOCOreg NEOLIFEreglsquos Research Centre specialising in

green technologies in partnership with European experts

EXCEPTIONAL WOOD FIBER CONTENTVESTAreg revolutionises eco-materials and the design of

environmental solutions for construction projects and the

landscaping of outside spaces It finally brings a response

to the architects landscapers and design officesrsquo

demands working on eco-construction and sustainable

development projects

ECO-FRIENDLYThe wood fibres contained in VESTAreg come exclusively

from sawmills offcuts the wood coming from sustainably

managed European forests The production of our material

does not require the cutting of any trees and does not use treated wood from recycled pallets Moreover

NEOLIFE does not use any toxic additives in the production process of the material

VESTAreg is 100 recyclable with a perfect traceability it only contains virgin substances (no recycled

components for which establishing a traceability is impossible)

CLEANDoes not contain solvents adhesives or phthalates and does not generate

toxic emissions

STABLE AND RESISTANTVESTAreg fibres benefit from a thermal treatment which provides hydrophobic properties to the material The

formula reinforced with mineral resin lignin and antioxidants enables a remarkable mechanical resistance as

well as an outstanding design

The mineral pigments also offer a strong resistance to UV rays making the colours more durable whatever the

exposure

SOURCE

Raw material VESTAreg

X-FIRE is highly fire-resistant Wood fibres coming from sustainably managed European forests

Board Production France

COMPOSITIONby Volume 75 wood fibres mineral oil mineral salts mineral pigments

PHYSICAL PROPERTIES

Mass sqm COVER 6 195 kgmsup2 COVER 14 165 kgmsup2

Density 1500 kgm3

Parasite resistance Equivalent to use class 4 No development of fungal rot mosses or mould Insect-resistant including termites

Surface appearance Micro-striated surface splinter free blisters or flakes off Maintenance-free

Scratches resistance Equivalent to natural wood - Brushing possible without discolouration

Thermal inertia Low thermal inertia due to the high wood fibres content

ENVIRONMENTAL PROPERTIES

Recycling 100 recyclable 75 renewable and combustible (75 biomass)

Toxic substances Contains no toxic or dangerous products (according to Reach Regulation EC19072006)

Chemical fire retardant substance None

Solvents None

Heavy metals None lead-and mercury-free stabilization

Phthalates adhesives None

Formaldehydes and VOCs Lower than or equal to natural wood

VESTAreg REINFORCED WOOD FIBER

VESTA X-FIRE

ENVIRONMENTAL PRODUCT DECLARATION

1 - Values describing the environmental impacts

Owner of the declaration NEOLIFE Editor BUREAU VERITAS CODDE Declaration reference DEP_NEOLIFE_COVER_201507

Publication 10072015 Validity 10072020

Complies with the standard ISO 14025 NF EN 15804+A1 And itrsquos national addendum X P01-064CN

Environmental Declaration of the COVER productavailable on request

ENVIRONMENTAL PRODUCT DECLARATION

2 ndash Values describing the use of primary energetic sources other resources and water

3 ndash Complementary values describing the outflows

FURTHER DETAILS

33

TECHNICAL DESCRIPTION

French accreditaion type laquo Avis Technique Expeacuterimental de Type A raquo issued by CSTB (France)

Ndeg2278 ndash Available at httpevaluationcstbfrrechercherproduits-evaluesprestations=atex

VESTA Reinforced Wood Fiber cladding containing at least 75 wood fibres

Boards with a slatted aspect featuring 6 cm or 14 cm ribs

Fire rating with natural mineral salts following EN 13501-12007

COVER 6 B-s3-d0 minimum

COVER 14 B-s3-d0 minimum

Invisible fixing with stainless steel hooks screwed into wood or metal battens

Fast and accurate fitting thanks to the interlocking board system

Outside corners catered for by using 45deg miter cuts or aluminium corner profile

Dimensional stability of maximum 2mm m over ∆80degC

rot-proof not sensitive to moss and mould

Insect-resistant termites included

Stable colors after natural patina is acquired

Contact us to get the full technical specification sheet

CONTACT

CAUTION

This technical sheet is associated with the technical installation guide of CLAD claddingboard available at wwwneolife-solutionscom

NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters

disposal for any clarifications concerning the installation procedure of its products

The specifications and recommendations given in the installation guide are not a

substitute to regulations concerning safety environment and professional regulatory

dispositions

All instructions concerning the installation of our cladding are to be followed

Assembly errors are not covered by the NEOLIFEreg guarantee

An approved fitter shall be able to assess the construction conformity to the local

professional installation guidelines

304 Route Nationale 6 ndash Celtic Parc Bacirctiment Avalon II - 69760 Limonest FranceTel +33 (0)4 78 25 63 08 ndash Fax +33 (0)4 72 29 29 47

wwwneolife-solutionscom

Page 23: COVER 6 & 14 CLADDING · 2020. 11. 3. · 60 cm centre-to-centre spacing 10 / m ... sill and causes stains onto the cladding after raining WINDOW SILL Advice : Make a window sill

LONG LASTING

VERY LIMITED MAINTENANCE

The material does not require any wood preservative (oils varnishes saturators hellip)

bull The VESTAreg material is naturally equivalent to use class 4(service environment In contact with ground or fresh water amp Permanently exposed to wetting The use classes rank the risk of exposure to decay and insect attack for differing in service environments according to EN 335 ndash 2)

bull Highly hydrophobic and rot-proof no algae fungi or moss development

bull Insect-resistant does not require any treatments against termites

STAIN REMOVAL

STAINS

Tanin stains

During the first weeks after installation tannin rings may occur because of the rain especially

on claddings with a light colour They will be washed off and fade during the next rain to

lessen until they completely disappear Be careful not to mistake these stains with dust or

pollution stains which appear on all cladding types

Bleach-based cleaning products

Slight discolouration Clean with water and complete if needed with slight brushing in the

boards orientation

Graffities oil paint and ink

Use a specialised stain remover (ex laquo STG 105 BIO raquo de STG)

Bitumen grease

Use a specialised stain remover (ex laquo Scalp Aqua 03 raquo)

Oxidation stains after contact with a corroded metal

Use a specialised wood de-greyer (ex laquo Scalp Neutral DA 66 raquo)

Caution

- Analyse properly the substance to clean so to use the right stain removing product

- Always test the stain removing product on a small and discrete surface before cleaning the

entire board

- It is mandatory that you analyse on a long time scale (and after exposure to Uvs) that the

solution you choose will not react with the cladding and therefore produce unsightly effects

DAMAGES

bull Scratches cigarette marks abrasion Brush away with a brass brush (lengthways)

TECHNICAL CHARACTERISTICS

25

SYSTEM PERFORMANCES

DESIGNATIONTEST

METHODS amp STANDARDS

CLADDING OUTLIFE COVER 6 amp 14

WIND LOAD (Depression) COVER 6 (4 ribs) COVER 14 (2 ribss)

Fixings description Eurocodes EN 1991-1-4 Test results Maximum shearing

pressure Test results Maximum shearingpressure

Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction

4 900 Pa

(degradation)140 kNm2 5 200 Pa

(degradation) 148 kNm2

Maximum 400mm centre-to-centre support spacing with one fixing tab at every junction 8 300 Pa (ruine) 237 kNm2 8 300 Pa (ruine) 237 kNm2

IMPACT RESISTANCE COVER 6 (4 ribs) COVER 14 (2 ribs)

Fixings description NF P 08302 Test results Test results

Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction

No damage with the impact energies below

Soft impacts 50Kg 130J

Soft impacts 3Kg 20J

Hard impacts 1Kg 3J

No damage with the impact energies below Soft impacts 50Kg 130J

Soft impacts 3Kg 20JHard impacts 1Kg 3J

SEISMIC RESISTANCE COVER 6 amp14

COVER 6 amp 14can be installed in seismic zones and buildings according to the following details

Highest seismic behaviour following Eurocode 8 no risk of falling boards or permanent deformations after static and dynamic test

FIRE RESISTANCE COVER 6 COVER 14

Tests description EN 13823 et EN 13501-12007

Fire rating

(on A2-s1d0 wall)

Fire rating

(on A2-s1d0 wall)

SBI test carried out on 3 models forming a 1500mm high 1000mm long and 500mm wide

dihedral wedge Assembly on air board and horizontal wood batten Valable contre un

substrat A2-s1d0

B-s3d0

Equivalent UK class 0

FIGRA average 1151Ws

THR average 6MJ

SMOGRA average 371 m2s2

B-s3d0

Equivalent UK class 0

FIGRA average 1924Ws

THR average 112MJ

SMOGRA average 592m2s2

Horizontal installation Class B-s3 d0 - Vertical installation on metal framework Class B s3 d0 on wooden framework Class C s3 d0 (EN 13501-12007)

PHYSICAL AND MECHANICAL FEATURES

DESIGNATION TEST METHODES amp STANDARDS COVER 6 amp 14 OUTLIFE CLADDING

FLAMMABLE MASS COVER 6 COVER 14Tests description NF EN 13238 Flammable mass per sqm (MJ)Tests realised according to the crucible method on at least 5 product samples 334 MJ 285 MJ

APPEARANCE DURABILITY(ageing under QUV) COVER 6 amp 14

Test descriptionNF EN 927-6 (2006)

FCBA‐ LBO6-PHY‐001

Test results

Artificial ageing test under QUV allowing an assessment of durability and decorative

properties modification Total duration 10 weeks comprising

condensation UV radiation and water spray phases

Stable products according to the EN 927-2

No blistering defects are observed according to ISO 4628-2 standard Resultt 0No cracking defects are observed according to ISO 4628-4 standard Result 0No flaking defects are observed according to ISO 4628-5 standard Result 0

THERMAL EXPANSION COVER 6 amp 14

Test description

ISO 11359-2 adapted to

FCBA - LBO6PHY-001

Test results

Thermodilatometric test in climatic room going from -20deg to +60deg to determine the profils

thermal expansion coefficient in solid state

Coefficient de dilatation thermique moyen

Longitudinally δL = 380 degK-1 10-6 standard spacing 210 degK-1 10-6 For uninstalled boardsTransversally δB = 575 degK-1 10-6 standard spacing 211 degK-1 10-6 For uninstalled boards

WATER UPTAKE DETERMINATION COVER 6 amp 14

Test description FCBA‐LBO‐MECA‐014 Test results

Water uptake determination after immersion in cold water during 28 days Measure of the

mass in its initial state and after 124714 et 28 days

Boards suitable to use in class 4 (Wood use class NF EN 335-2)Boards naturally resistant against fungus and soft rotAverage water uptake after 28 days 803Water content at 28 days and imputed to the cellulosic matter 143

ELASTICITY CONSTRAINS AND MODULE IN FLEXION COVER 6 amp 14

Test description

FCBA‐LBO‐MECA‐008

NF EN 310 modifiedWPC profiles

Test results

3 point flexion under normal conditions 20degCand 65 RH

Eaverage = 904 Nmm2fm = 40 Nmm2

ENVIRONMENTAL CHARACTERISTICS

28

VESTAreg ECO-MATERIAL

VESTAreg (Vegetal Ecological Stable Timber

Advantage) is an innovative and eco-friendly compound

with exceptional properties It was developed by

NEOCOreg NEOLIFEreglsquos Research Centre specialising in

green technologies in partnership with European experts

EXCEPTIONAL WOOD FIBER CONTENTVESTAreg revolutionises eco-materials and the design of

environmental solutions for construction projects and the

landscaping of outside spaces It finally brings a response

to the architects landscapers and design officesrsquo

demands working on eco-construction and sustainable

development projects

ECO-FRIENDLYThe wood fibres contained in VESTAreg come exclusively

from sawmills offcuts the wood coming from sustainably

managed European forests The production of our material

does not require the cutting of any trees and does not use treated wood from recycled pallets Moreover

NEOLIFE does not use any toxic additives in the production process of the material

VESTAreg is 100 recyclable with a perfect traceability it only contains virgin substances (no recycled

components for which establishing a traceability is impossible)

CLEANDoes not contain solvents adhesives or phthalates and does not generate

toxic emissions

STABLE AND RESISTANTVESTAreg fibres benefit from a thermal treatment which provides hydrophobic properties to the material The

formula reinforced with mineral resin lignin and antioxidants enables a remarkable mechanical resistance as

well as an outstanding design

The mineral pigments also offer a strong resistance to UV rays making the colours more durable whatever the

exposure

SOURCE

Raw material VESTAreg

X-FIRE is highly fire-resistant Wood fibres coming from sustainably managed European forests

Board Production France

COMPOSITIONby Volume 75 wood fibres mineral oil mineral salts mineral pigments

PHYSICAL PROPERTIES

Mass sqm COVER 6 195 kgmsup2 COVER 14 165 kgmsup2

Density 1500 kgm3

Parasite resistance Equivalent to use class 4 No development of fungal rot mosses or mould Insect-resistant including termites

Surface appearance Micro-striated surface splinter free blisters or flakes off Maintenance-free

Scratches resistance Equivalent to natural wood - Brushing possible without discolouration

Thermal inertia Low thermal inertia due to the high wood fibres content

ENVIRONMENTAL PROPERTIES

Recycling 100 recyclable 75 renewable and combustible (75 biomass)

Toxic substances Contains no toxic or dangerous products (according to Reach Regulation EC19072006)

Chemical fire retardant substance None

Solvents None

Heavy metals None lead-and mercury-free stabilization

Phthalates adhesives None

Formaldehydes and VOCs Lower than or equal to natural wood

VESTAreg REINFORCED WOOD FIBER

VESTA X-FIRE

ENVIRONMENTAL PRODUCT DECLARATION

1 - Values describing the environmental impacts

Owner of the declaration NEOLIFE Editor BUREAU VERITAS CODDE Declaration reference DEP_NEOLIFE_COVER_201507

Publication 10072015 Validity 10072020

Complies with the standard ISO 14025 NF EN 15804+A1 And itrsquos national addendum X P01-064CN

Environmental Declaration of the COVER productavailable on request

ENVIRONMENTAL PRODUCT DECLARATION

2 ndash Values describing the use of primary energetic sources other resources and water

3 ndash Complementary values describing the outflows

FURTHER DETAILS

33

TECHNICAL DESCRIPTION

French accreditaion type laquo Avis Technique Expeacuterimental de Type A raquo issued by CSTB (France)

Ndeg2278 ndash Available at httpevaluationcstbfrrechercherproduits-evaluesprestations=atex

VESTA Reinforced Wood Fiber cladding containing at least 75 wood fibres

Boards with a slatted aspect featuring 6 cm or 14 cm ribs

Fire rating with natural mineral salts following EN 13501-12007

COVER 6 B-s3-d0 minimum

COVER 14 B-s3-d0 minimum

Invisible fixing with stainless steel hooks screwed into wood or metal battens

Fast and accurate fitting thanks to the interlocking board system

Outside corners catered for by using 45deg miter cuts or aluminium corner profile

Dimensional stability of maximum 2mm m over ∆80degC

rot-proof not sensitive to moss and mould

Insect-resistant termites included

Stable colors after natural patina is acquired

Contact us to get the full technical specification sheet

CONTACT

CAUTION

This technical sheet is associated with the technical installation guide of CLAD claddingboard available at wwwneolife-solutionscom

NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters

disposal for any clarifications concerning the installation procedure of its products

The specifications and recommendations given in the installation guide are not a

substitute to regulations concerning safety environment and professional regulatory

dispositions

All instructions concerning the installation of our cladding are to be followed

Assembly errors are not covered by the NEOLIFEreg guarantee

An approved fitter shall be able to assess the construction conformity to the local

professional installation guidelines

304 Route Nationale 6 ndash Celtic Parc Bacirctiment Avalon II - 69760 Limonest FranceTel +33 (0)4 78 25 63 08 ndash Fax +33 (0)4 72 29 29 47

wwwneolife-solutionscom

Page 24: COVER 6 & 14 CLADDING · 2020. 11. 3. · 60 cm centre-to-centre spacing 10 / m ... sill and causes stains onto the cladding after raining WINDOW SILL Advice : Make a window sill

STAIN REMOVAL

STAINS

Tanin stains

During the first weeks after installation tannin rings may occur because of the rain especially

on claddings with a light colour They will be washed off and fade during the next rain to

lessen until they completely disappear Be careful not to mistake these stains with dust or

pollution stains which appear on all cladding types

Bleach-based cleaning products

Slight discolouration Clean with water and complete if needed with slight brushing in the

boards orientation

Graffities oil paint and ink

Use a specialised stain remover (ex laquo STG 105 BIO raquo de STG)

Bitumen grease

Use a specialised stain remover (ex laquo Scalp Aqua 03 raquo)

Oxidation stains after contact with a corroded metal

Use a specialised wood de-greyer (ex laquo Scalp Neutral DA 66 raquo)

Caution

- Analyse properly the substance to clean so to use the right stain removing product

- Always test the stain removing product on a small and discrete surface before cleaning the

entire board

- It is mandatory that you analyse on a long time scale (and after exposure to Uvs) that the

solution you choose will not react with the cladding and therefore produce unsightly effects

DAMAGES

bull Scratches cigarette marks abrasion Brush away with a brass brush (lengthways)

TECHNICAL CHARACTERISTICS

25

SYSTEM PERFORMANCES

DESIGNATIONTEST

METHODS amp STANDARDS

CLADDING OUTLIFE COVER 6 amp 14

WIND LOAD (Depression) COVER 6 (4 ribs) COVER 14 (2 ribss)

Fixings description Eurocodes EN 1991-1-4 Test results Maximum shearing

pressure Test results Maximum shearingpressure

Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction

4 900 Pa

(degradation)140 kNm2 5 200 Pa

(degradation) 148 kNm2

Maximum 400mm centre-to-centre support spacing with one fixing tab at every junction 8 300 Pa (ruine) 237 kNm2 8 300 Pa (ruine) 237 kNm2

IMPACT RESISTANCE COVER 6 (4 ribs) COVER 14 (2 ribs)

Fixings description NF P 08302 Test results Test results

Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction

No damage with the impact energies below

Soft impacts 50Kg 130J

Soft impacts 3Kg 20J

Hard impacts 1Kg 3J

No damage with the impact energies below Soft impacts 50Kg 130J

Soft impacts 3Kg 20JHard impacts 1Kg 3J

SEISMIC RESISTANCE COVER 6 amp14

COVER 6 amp 14can be installed in seismic zones and buildings according to the following details

Highest seismic behaviour following Eurocode 8 no risk of falling boards or permanent deformations after static and dynamic test

FIRE RESISTANCE COVER 6 COVER 14

Tests description EN 13823 et EN 13501-12007

Fire rating

(on A2-s1d0 wall)

Fire rating

(on A2-s1d0 wall)

SBI test carried out on 3 models forming a 1500mm high 1000mm long and 500mm wide

dihedral wedge Assembly on air board and horizontal wood batten Valable contre un

substrat A2-s1d0

B-s3d0

Equivalent UK class 0

FIGRA average 1151Ws

THR average 6MJ

SMOGRA average 371 m2s2

B-s3d0

Equivalent UK class 0

FIGRA average 1924Ws

THR average 112MJ

SMOGRA average 592m2s2

Horizontal installation Class B-s3 d0 - Vertical installation on metal framework Class B s3 d0 on wooden framework Class C s3 d0 (EN 13501-12007)

PHYSICAL AND MECHANICAL FEATURES

DESIGNATION TEST METHODES amp STANDARDS COVER 6 amp 14 OUTLIFE CLADDING

FLAMMABLE MASS COVER 6 COVER 14Tests description NF EN 13238 Flammable mass per sqm (MJ)Tests realised according to the crucible method on at least 5 product samples 334 MJ 285 MJ

APPEARANCE DURABILITY(ageing under QUV) COVER 6 amp 14

Test descriptionNF EN 927-6 (2006)

FCBA‐ LBO6-PHY‐001

Test results

Artificial ageing test under QUV allowing an assessment of durability and decorative

properties modification Total duration 10 weeks comprising

condensation UV radiation and water spray phases

Stable products according to the EN 927-2

No blistering defects are observed according to ISO 4628-2 standard Resultt 0No cracking defects are observed according to ISO 4628-4 standard Result 0No flaking defects are observed according to ISO 4628-5 standard Result 0

THERMAL EXPANSION COVER 6 amp 14

Test description

ISO 11359-2 adapted to

FCBA - LBO6PHY-001

Test results

Thermodilatometric test in climatic room going from -20deg to +60deg to determine the profils

thermal expansion coefficient in solid state

Coefficient de dilatation thermique moyen

Longitudinally δL = 380 degK-1 10-6 standard spacing 210 degK-1 10-6 For uninstalled boardsTransversally δB = 575 degK-1 10-6 standard spacing 211 degK-1 10-6 For uninstalled boards

WATER UPTAKE DETERMINATION COVER 6 amp 14

Test description FCBA‐LBO‐MECA‐014 Test results

Water uptake determination after immersion in cold water during 28 days Measure of the

mass in its initial state and after 124714 et 28 days

Boards suitable to use in class 4 (Wood use class NF EN 335-2)Boards naturally resistant against fungus and soft rotAverage water uptake after 28 days 803Water content at 28 days and imputed to the cellulosic matter 143

ELASTICITY CONSTRAINS AND MODULE IN FLEXION COVER 6 amp 14

Test description

FCBA‐LBO‐MECA‐008

NF EN 310 modifiedWPC profiles

Test results

3 point flexion under normal conditions 20degCand 65 RH

Eaverage = 904 Nmm2fm = 40 Nmm2

ENVIRONMENTAL CHARACTERISTICS

28

VESTAreg ECO-MATERIAL

VESTAreg (Vegetal Ecological Stable Timber

Advantage) is an innovative and eco-friendly compound

with exceptional properties It was developed by

NEOCOreg NEOLIFEreglsquos Research Centre specialising in

green technologies in partnership with European experts

EXCEPTIONAL WOOD FIBER CONTENTVESTAreg revolutionises eco-materials and the design of

environmental solutions for construction projects and the

landscaping of outside spaces It finally brings a response

to the architects landscapers and design officesrsquo

demands working on eco-construction and sustainable

development projects

ECO-FRIENDLYThe wood fibres contained in VESTAreg come exclusively

from sawmills offcuts the wood coming from sustainably

managed European forests The production of our material

does not require the cutting of any trees and does not use treated wood from recycled pallets Moreover

NEOLIFE does not use any toxic additives in the production process of the material

VESTAreg is 100 recyclable with a perfect traceability it only contains virgin substances (no recycled

components for which establishing a traceability is impossible)

CLEANDoes not contain solvents adhesives or phthalates and does not generate

toxic emissions

STABLE AND RESISTANTVESTAreg fibres benefit from a thermal treatment which provides hydrophobic properties to the material The

formula reinforced with mineral resin lignin and antioxidants enables a remarkable mechanical resistance as

well as an outstanding design

The mineral pigments also offer a strong resistance to UV rays making the colours more durable whatever the

exposure

SOURCE

Raw material VESTAreg

X-FIRE is highly fire-resistant Wood fibres coming from sustainably managed European forests

Board Production France

COMPOSITIONby Volume 75 wood fibres mineral oil mineral salts mineral pigments

PHYSICAL PROPERTIES

Mass sqm COVER 6 195 kgmsup2 COVER 14 165 kgmsup2

Density 1500 kgm3

Parasite resistance Equivalent to use class 4 No development of fungal rot mosses or mould Insect-resistant including termites

Surface appearance Micro-striated surface splinter free blisters or flakes off Maintenance-free

Scratches resistance Equivalent to natural wood - Brushing possible without discolouration

Thermal inertia Low thermal inertia due to the high wood fibres content

ENVIRONMENTAL PROPERTIES

Recycling 100 recyclable 75 renewable and combustible (75 biomass)

Toxic substances Contains no toxic or dangerous products (according to Reach Regulation EC19072006)

Chemical fire retardant substance None

Solvents None

Heavy metals None lead-and mercury-free stabilization

Phthalates adhesives None

Formaldehydes and VOCs Lower than or equal to natural wood

VESTAreg REINFORCED WOOD FIBER

VESTA X-FIRE

ENVIRONMENTAL PRODUCT DECLARATION

1 - Values describing the environmental impacts

Owner of the declaration NEOLIFE Editor BUREAU VERITAS CODDE Declaration reference DEP_NEOLIFE_COVER_201507

Publication 10072015 Validity 10072020

Complies with the standard ISO 14025 NF EN 15804+A1 And itrsquos national addendum X P01-064CN

Environmental Declaration of the COVER productavailable on request

ENVIRONMENTAL PRODUCT DECLARATION

2 ndash Values describing the use of primary energetic sources other resources and water

3 ndash Complementary values describing the outflows

FURTHER DETAILS

33

TECHNICAL DESCRIPTION

French accreditaion type laquo Avis Technique Expeacuterimental de Type A raquo issued by CSTB (France)

Ndeg2278 ndash Available at httpevaluationcstbfrrechercherproduits-evaluesprestations=atex

VESTA Reinforced Wood Fiber cladding containing at least 75 wood fibres

Boards with a slatted aspect featuring 6 cm or 14 cm ribs

Fire rating with natural mineral salts following EN 13501-12007

COVER 6 B-s3-d0 minimum

COVER 14 B-s3-d0 minimum

Invisible fixing with stainless steel hooks screwed into wood or metal battens

Fast and accurate fitting thanks to the interlocking board system

Outside corners catered for by using 45deg miter cuts or aluminium corner profile

Dimensional stability of maximum 2mm m over ∆80degC

rot-proof not sensitive to moss and mould

Insect-resistant termites included

Stable colors after natural patina is acquired

Contact us to get the full technical specification sheet

CONTACT

CAUTION

This technical sheet is associated with the technical installation guide of CLAD claddingboard available at wwwneolife-solutionscom

NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters

disposal for any clarifications concerning the installation procedure of its products

The specifications and recommendations given in the installation guide are not a

substitute to regulations concerning safety environment and professional regulatory

dispositions

All instructions concerning the installation of our cladding are to be followed

Assembly errors are not covered by the NEOLIFEreg guarantee

An approved fitter shall be able to assess the construction conformity to the local

professional installation guidelines

304 Route Nationale 6 ndash Celtic Parc Bacirctiment Avalon II - 69760 Limonest FranceTel +33 (0)4 78 25 63 08 ndash Fax +33 (0)4 72 29 29 47

wwwneolife-solutionscom

Page 25: COVER 6 & 14 CLADDING · 2020. 11. 3. · 60 cm centre-to-centre spacing 10 / m ... sill and causes stains onto the cladding after raining WINDOW SILL Advice : Make a window sill

TECHNICAL CHARACTERISTICS

25

SYSTEM PERFORMANCES

DESIGNATIONTEST

METHODS amp STANDARDS

CLADDING OUTLIFE COVER 6 amp 14

WIND LOAD (Depression) COVER 6 (4 ribs) COVER 14 (2 ribss)

Fixings description Eurocodes EN 1991-1-4 Test results Maximum shearing

pressure Test results Maximum shearingpressure

Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction

4 900 Pa

(degradation)140 kNm2 5 200 Pa

(degradation) 148 kNm2

Maximum 400mm centre-to-centre support spacing with one fixing tab at every junction 8 300 Pa (ruine) 237 kNm2 8 300 Pa (ruine) 237 kNm2

IMPACT RESISTANCE COVER 6 (4 ribs) COVER 14 (2 ribs)

Fixings description NF P 08302 Test results Test results

Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction

No damage with the impact energies below

Soft impacts 50Kg 130J

Soft impacts 3Kg 20J

Hard impacts 1Kg 3J

No damage with the impact energies below Soft impacts 50Kg 130J

Soft impacts 3Kg 20JHard impacts 1Kg 3J

SEISMIC RESISTANCE COVER 6 amp14

COVER 6 amp 14can be installed in seismic zones and buildings according to the following details

Highest seismic behaviour following Eurocode 8 no risk of falling boards or permanent deformations after static and dynamic test

FIRE RESISTANCE COVER 6 COVER 14

Tests description EN 13823 et EN 13501-12007

Fire rating

(on A2-s1d0 wall)

Fire rating

(on A2-s1d0 wall)

SBI test carried out on 3 models forming a 1500mm high 1000mm long and 500mm wide

dihedral wedge Assembly on air board and horizontal wood batten Valable contre un

substrat A2-s1d0

B-s3d0

Equivalent UK class 0

FIGRA average 1151Ws

THR average 6MJ

SMOGRA average 371 m2s2

B-s3d0

Equivalent UK class 0

FIGRA average 1924Ws

THR average 112MJ

SMOGRA average 592m2s2

Horizontal installation Class B-s3 d0 - Vertical installation on metal framework Class B s3 d0 on wooden framework Class C s3 d0 (EN 13501-12007)

PHYSICAL AND MECHANICAL FEATURES

DESIGNATION TEST METHODES amp STANDARDS COVER 6 amp 14 OUTLIFE CLADDING

FLAMMABLE MASS COVER 6 COVER 14Tests description NF EN 13238 Flammable mass per sqm (MJ)Tests realised according to the crucible method on at least 5 product samples 334 MJ 285 MJ

APPEARANCE DURABILITY(ageing under QUV) COVER 6 amp 14

Test descriptionNF EN 927-6 (2006)

FCBA‐ LBO6-PHY‐001

Test results

Artificial ageing test under QUV allowing an assessment of durability and decorative

properties modification Total duration 10 weeks comprising

condensation UV radiation and water spray phases

Stable products according to the EN 927-2

No blistering defects are observed according to ISO 4628-2 standard Resultt 0No cracking defects are observed according to ISO 4628-4 standard Result 0No flaking defects are observed according to ISO 4628-5 standard Result 0

THERMAL EXPANSION COVER 6 amp 14

Test description

ISO 11359-2 adapted to

FCBA - LBO6PHY-001

Test results

Thermodilatometric test in climatic room going from -20deg to +60deg to determine the profils

thermal expansion coefficient in solid state

Coefficient de dilatation thermique moyen

Longitudinally δL = 380 degK-1 10-6 standard spacing 210 degK-1 10-6 For uninstalled boardsTransversally δB = 575 degK-1 10-6 standard spacing 211 degK-1 10-6 For uninstalled boards

WATER UPTAKE DETERMINATION COVER 6 amp 14

Test description FCBA‐LBO‐MECA‐014 Test results

Water uptake determination after immersion in cold water during 28 days Measure of the

mass in its initial state and after 124714 et 28 days

Boards suitable to use in class 4 (Wood use class NF EN 335-2)Boards naturally resistant against fungus and soft rotAverage water uptake after 28 days 803Water content at 28 days and imputed to the cellulosic matter 143

ELASTICITY CONSTRAINS AND MODULE IN FLEXION COVER 6 amp 14

Test description

FCBA‐LBO‐MECA‐008

NF EN 310 modifiedWPC profiles

Test results

3 point flexion under normal conditions 20degCand 65 RH

Eaverage = 904 Nmm2fm = 40 Nmm2

ENVIRONMENTAL CHARACTERISTICS

28

VESTAreg ECO-MATERIAL

VESTAreg (Vegetal Ecological Stable Timber

Advantage) is an innovative and eco-friendly compound

with exceptional properties It was developed by

NEOCOreg NEOLIFEreglsquos Research Centre specialising in

green technologies in partnership with European experts

EXCEPTIONAL WOOD FIBER CONTENTVESTAreg revolutionises eco-materials and the design of

environmental solutions for construction projects and the

landscaping of outside spaces It finally brings a response

to the architects landscapers and design officesrsquo

demands working on eco-construction and sustainable

development projects

ECO-FRIENDLYThe wood fibres contained in VESTAreg come exclusively

from sawmills offcuts the wood coming from sustainably

managed European forests The production of our material

does not require the cutting of any trees and does not use treated wood from recycled pallets Moreover

NEOLIFE does not use any toxic additives in the production process of the material

VESTAreg is 100 recyclable with a perfect traceability it only contains virgin substances (no recycled

components for which establishing a traceability is impossible)

CLEANDoes not contain solvents adhesives or phthalates and does not generate

toxic emissions

STABLE AND RESISTANTVESTAreg fibres benefit from a thermal treatment which provides hydrophobic properties to the material The

formula reinforced with mineral resin lignin and antioxidants enables a remarkable mechanical resistance as

well as an outstanding design

The mineral pigments also offer a strong resistance to UV rays making the colours more durable whatever the

exposure

SOURCE

Raw material VESTAreg

X-FIRE is highly fire-resistant Wood fibres coming from sustainably managed European forests

Board Production France

COMPOSITIONby Volume 75 wood fibres mineral oil mineral salts mineral pigments

PHYSICAL PROPERTIES

Mass sqm COVER 6 195 kgmsup2 COVER 14 165 kgmsup2

Density 1500 kgm3

Parasite resistance Equivalent to use class 4 No development of fungal rot mosses or mould Insect-resistant including termites

Surface appearance Micro-striated surface splinter free blisters or flakes off Maintenance-free

Scratches resistance Equivalent to natural wood - Brushing possible without discolouration

Thermal inertia Low thermal inertia due to the high wood fibres content

ENVIRONMENTAL PROPERTIES

Recycling 100 recyclable 75 renewable and combustible (75 biomass)

Toxic substances Contains no toxic or dangerous products (according to Reach Regulation EC19072006)

Chemical fire retardant substance None

Solvents None

Heavy metals None lead-and mercury-free stabilization

Phthalates adhesives None

Formaldehydes and VOCs Lower than or equal to natural wood

VESTAreg REINFORCED WOOD FIBER

VESTA X-FIRE

ENVIRONMENTAL PRODUCT DECLARATION

1 - Values describing the environmental impacts

Owner of the declaration NEOLIFE Editor BUREAU VERITAS CODDE Declaration reference DEP_NEOLIFE_COVER_201507

Publication 10072015 Validity 10072020

Complies with the standard ISO 14025 NF EN 15804+A1 And itrsquos national addendum X P01-064CN

Environmental Declaration of the COVER productavailable on request

ENVIRONMENTAL PRODUCT DECLARATION

2 ndash Values describing the use of primary energetic sources other resources and water

3 ndash Complementary values describing the outflows

FURTHER DETAILS

33

TECHNICAL DESCRIPTION

French accreditaion type laquo Avis Technique Expeacuterimental de Type A raquo issued by CSTB (France)

Ndeg2278 ndash Available at httpevaluationcstbfrrechercherproduits-evaluesprestations=atex

VESTA Reinforced Wood Fiber cladding containing at least 75 wood fibres

Boards with a slatted aspect featuring 6 cm or 14 cm ribs

Fire rating with natural mineral salts following EN 13501-12007

COVER 6 B-s3-d0 minimum

COVER 14 B-s3-d0 minimum

Invisible fixing with stainless steel hooks screwed into wood or metal battens

Fast and accurate fitting thanks to the interlocking board system

Outside corners catered for by using 45deg miter cuts or aluminium corner profile

Dimensional stability of maximum 2mm m over ∆80degC

rot-proof not sensitive to moss and mould

Insect-resistant termites included

Stable colors after natural patina is acquired

Contact us to get the full technical specification sheet

CONTACT

CAUTION

This technical sheet is associated with the technical installation guide of CLAD claddingboard available at wwwneolife-solutionscom

NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters

disposal for any clarifications concerning the installation procedure of its products

The specifications and recommendations given in the installation guide are not a

substitute to regulations concerning safety environment and professional regulatory

dispositions

All instructions concerning the installation of our cladding are to be followed

Assembly errors are not covered by the NEOLIFEreg guarantee

An approved fitter shall be able to assess the construction conformity to the local

professional installation guidelines

304 Route Nationale 6 ndash Celtic Parc Bacirctiment Avalon II - 69760 Limonest FranceTel +33 (0)4 78 25 63 08 ndash Fax +33 (0)4 72 29 29 47

wwwneolife-solutionscom

Page 26: COVER 6 & 14 CLADDING · 2020. 11. 3. · 60 cm centre-to-centre spacing 10 / m ... sill and causes stains onto the cladding after raining WINDOW SILL Advice : Make a window sill

SYSTEM PERFORMANCES

DESIGNATIONTEST

METHODS amp STANDARDS

CLADDING OUTLIFE COVER 6 amp 14

WIND LOAD (Depression) COVER 6 (4 ribs) COVER 14 (2 ribss)

Fixings description Eurocodes EN 1991-1-4 Test results Maximum shearing

pressure Test results Maximum shearingpressure

Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction

4 900 Pa

(degradation)140 kNm2 5 200 Pa

(degradation) 148 kNm2

Maximum 400mm centre-to-centre support spacing with one fixing tab at every junction 8 300 Pa (ruine) 237 kNm2 8 300 Pa (ruine) 237 kNm2

IMPACT RESISTANCE COVER 6 (4 ribs) COVER 14 (2 ribs)

Fixings description NF P 08302 Test results Test results

Maximum 600mm centre-to-centre support spacing with one fixing tab at every junction

No damage with the impact energies below

Soft impacts 50Kg 130J

Soft impacts 3Kg 20J

Hard impacts 1Kg 3J

No damage with the impact energies below Soft impacts 50Kg 130J

Soft impacts 3Kg 20JHard impacts 1Kg 3J

SEISMIC RESISTANCE COVER 6 amp14

COVER 6 amp 14can be installed in seismic zones and buildings according to the following details

Highest seismic behaviour following Eurocode 8 no risk of falling boards or permanent deformations after static and dynamic test

FIRE RESISTANCE COVER 6 COVER 14

Tests description EN 13823 et EN 13501-12007

Fire rating

(on A2-s1d0 wall)

Fire rating

(on A2-s1d0 wall)

SBI test carried out on 3 models forming a 1500mm high 1000mm long and 500mm wide

dihedral wedge Assembly on air board and horizontal wood batten Valable contre un

substrat A2-s1d0

B-s3d0

Equivalent UK class 0

FIGRA average 1151Ws

THR average 6MJ

SMOGRA average 371 m2s2

B-s3d0

Equivalent UK class 0

FIGRA average 1924Ws

THR average 112MJ

SMOGRA average 592m2s2

Horizontal installation Class B-s3 d0 - Vertical installation on metal framework Class B s3 d0 on wooden framework Class C s3 d0 (EN 13501-12007)

PHYSICAL AND MECHANICAL FEATURES

DESIGNATION TEST METHODES amp STANDARDS COVER 6 amp 14 OUTLIFE CLADDING

FLAMMABLE MASS COVER 6 COVER 14Tests description NF EN 13238 Flammable mass per sqm (MJ)Tests realised according to the crucible method on at least 5 product samples 334 MJ 285 MJ

APPEARANCE DURABILITY(ageing under QUV) COVER 6 amp 14

Test descriptionNF EN 927-6 (2006)

FCBA‐ LBO6-PHY‐001

Test results

Artificial ageing test under QUV allowing an assessment of durability and decorative

properties modification Total duration 10 weeks comprising

condensation UV radiation and water spray phases

Stable products according to the EN 927-2

No blistering defects are observed according to ISO 4628-2 standard Resultt 0No cracking defects are observed according to ISO 4628-4 standard Result 0No flaking defects are observed according to ISO 4628-5 standard Result 0

THERMAL EXPANSION COVER 6 amp 14

Test description

ISO 11359-2 adapted to

FCBA - LBO6PHY-001

Test results

Thermodilatometric test in climatic room going from -20deg to +60deg to determine the profils

thermal expansion coefficient in solid state

Coefficient de dilatation thermique moyen

Longitudinally δL = 380 degK-1 10-6 standard spacing 210 degK-1 10-6 For uninstalled boardsTransversally δB = 575 degK-1 10-6 standard spacing 211 degK-1 10-6 For uninstalled boards

WATER UPTAKE DETERMINATION COVER 6 amp 14

Test description FCBA‐LBO‐MECA‐014 Test results

Water uptake determination after immersion in cold water during 28 days Measure of the

mass in its initial state and after 124714 et 28 days

Boards suitable to use in class 4 (Wood use class NF EN 335-2)Boards naturally resistant against fungus and soft rotAverage water uptake after 28 days 803Water content at 28 days and imputed to the cellulosic matter 143

ELASTICITY CONSTRAINS AND MODULE IN FLEXION COVER 6 amp 14

Test description

FCBA‐LBO‐MECA‐008

NF EN 310 modifiedWPC profiles

Test results

3 point flexion under normal conditions 20degCand 65 RH

Eaverage = 904 Nmm2fm = 40 Nmm2

ENVIRONMENTAL CHARACTERISTICS

28

VESTAreg ECO-MATERIAL

VESTAreg (Vegetal Ecological Stable Timber

Advantage) is an innovative and eco-friendly compound

with exceptional properties It was developed by

NEOCOreg NEOLIFEreglsquos Research Centre specialising in

green technologies in partnership with European experts

EXCEPTIONAL WOOD FIBER CONTENTVESTAreg revolutionises eco-materials and the design of

environmental solutions for construction projects and the

landscaping of outside spaces It finally brings a response

to the architects landscapers and design officesrsquo

demands working on eco-construction and sustainable

development projects

ECO-FRIENDLYThe wood fibres contained in VESTAreg come exclusively

from sawmills offcuts the wood coming from sustainably

managed European forests The production of our material

does not require the cutting of any trees and does not use treated wood from recycled pallets Moreover

NEOLIFE does not use any toxic additives in the production process of the material

VESTAreg is 100 recyclable with a perfect traceability it only contains virgin substances (no recycled

components for which establishing a traceability is impossible)

CLEANDoes not contain solvents adhesives or phthalates and does not generate

toxic emissions

STABLE AND RESISTANTVESTAreg fibres benefit from a thermal treatment which provides hydrophobic properties to the material The

formula reinforced with mineral resin lignin and antioxidants enables a remarkable mechanical resistance as

well as an outstanding design

The mineral pigments also offer a strong resistance to UV rays making the colours more durable whatever the

exposure

SOURCE

Raw material VESTAreg

X-FIRE is highly fire-resistant Wood fibres coming from sustainably managed European forests

Board Production France

COMPOSITIONby Volume 75 wood fibres mineral oil mineral salts mineral pigments

PHYSICAL PROPERTIES

Mass sqm COVER 6 195 kgmsup2 COVER 14 165 kgmsup2

Density 1500 kgm3

Parasite resistance Equivalent to use class 4 No development of fungal rot mosses or mould Insect-resistant including termites

Surface appearance Micro-striated surface splinter free blisters or flakes off Maintenance-free

Scratches resistance Equivalent to natural wood - Brushing possible without discolouration

Thermal inertia Low thermal inertia due to the high wood fibres content

ENVIRONMENTAL PROPERTIES

Recycling 100 recyclable 75 renewable and combustible (75 biomass)

Toxic substances Contains no toxic or dangerous products (according to Reach Regulation EC19072006)

Chemical fire retardant substance None

Solvents None

Heavy metals None lead-and mercury-free stabilization

Phthalates adhesives None

Formaldehydes and VOCs Lower than or equal to natural wood

VESTAreg REINFORCED WOOD FIBER

VESTA X-FIRE

ENVIRONMENTAL PRODUCT DECLARATION

1 - Values describing the environmental impacts

Owner of the declaration NEOLIFE Editor BUREAU VERITAS CODDE Declaration reference DEP_NEOLIFE_COVER_201507

Publication 10072015 Validity 10072020

Complies with the standard ISO 14025 NF EN 15804+A1 And itrsquos national addendum X P01-064CN

Environmental Declaration of the COVER productavailable on request

ENVIRONMENTAL PRODUCT DECLARATION

2 ndash Values describing the use of primary energetic sources other resources and water

3 ndash Complementary values describing the outflows

FURTHER DETAILS

33

TECHNICAL DESCRIPTION

French accreditaion type laquo Avis Technique Expeacuterimental de Type A raquo issued by CSTB (France)

Ndeg2278 ndash Available at httpevaluationcstbfrrechercherproduits-evaluesprestations=atex

VESTA Reinforced Wood Fiber cladding containing at least 75 wood fibres

Boards with a slatted aspect featuring 6 cm or 14 cm ribs

Fire rating with natural mineral salts following EN 13501-12007

COVER 6 B-s3-d0 minimum

COVER 14 B-s3-d0 minimum

Invisible fixing with stainless steel hooks screwed into wood or metal battens

Fast and accurate fitting thanks to the interlocking board system

Outside corners catered for by using 45deg miter cuts or aluminium corner profile

Dimensional stability of maximum 2mm m over ∆80degC

rot-proof not sensitive to moss and mould

Insect-resistant termites included

Stable colors after natural patina is acquired

Contact us to get the full technical specification sheet

CONTACT

CAUTION

This technical sheet is associated with the technical installation guide of CLAD claddingboard available at wwwneolife-solutionscom

NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters

disposal for any clarifications concerning the installation procedure of its products

The specifications and recommendations given in the installation guide are not a

substitute to regulations concerning safety environment and professional regulatory

dispositions

All instructions concerning the installation of our cladding are to be followed

Assembly errors are not covered by the NEOLIFEreg guarantee

An approved fitter shall be able to assess the construction conformity to the local

professional installation guidelines

304 Route Nationale 6 ndash Celtic Parc Bacirctiment Avalon II - 69760 Limonest FranceTel +33 (0)4 78 25 63 08 ndash Fax +33 (0)4 72 29 29 47

wwwneolife-solutionscom

Page 27: COVER 6 & 14 CLADDING · 2020. 11. 3. · 60 cm centre-to-centre spacing 10 / m ... sill and causes stains onto the cladding after raining WINDOW SILL Advice : Make a window sill

PHYSICAL AND MECHANICAL FEATURES

DESIGNATION TEST METHODES amp STANDARDS COVER 6 amp 14 OUTLIFE CLADDING

FLAMMABLE MASS COVER 6 COVER 14Tests description NF EN 13238 Flammable mass per sqm (MJ)Tests realised according to the crucible method on at least 5 product samples 334 MJ 285 MJ

APPEARANCE DURABILITY(ageing under QUV) COVER 6 amp 14

Test descriptionNF EN 927-6 (2006)

FCBA‐ LBO6-PHY‐001

Test results

Artificial ageing test under QUV allowing an assessment of durability and decorative

properties modification Total duration 10 weeks comprising

condensation UV radiation and water spray phases

Stable products according to the EN 927-2

No blistering defects are observed according to ISO 4628-2 standard Resultt 0No cracking defects are observed according to ISO 4628-4 standard Result 0No flaking defects are observed according to ISO 4628-5 standard Result 0

THERMAL EXPANSION COVER 6 amp 14

Test description

ISO 11359-2 adapted to

FCBA - LBO6PHY-001

Test results

Thermodilatometric test in climatic room going from -20deg to +60deg to determine the profils

thermal expansion coefficient in solid state

Coefficient de dilatation thermique moyen

Longitudinally δL = 380 degK-1 10-6 standard spacing 210 degK-1 10-6 For uninstalled boardsTransversally δB = 575 degK-1 10-6 standard spacing 211 degK-1 10-6 For uninstalled boards

WATER UPTAKE DETERMINATION COVER 6 amp 14

Test description FCBA‐LBO‐MECA‐014 Test results

Water uptake determination after immersion in cold water during 28 days Measure of the

mass in its initial state and after 124714 et 28 days

Boards suitable to use in class 4 (Wood use class NF EN 335-2)Boards naturally resistant against fungus and soft rotAverage water uptake after 28 days 803Water content at 28 days and imputed to the cellulosic matter 143

ELASTICITY CONSTRAINS AND MODULE IN FLEXION COVER 6 amp 14

Test description

FCBA‐LBO‐MECA‐008

NF EN 310 modifiedWPC profiles

Test results

3 point flexion under normal conditions 20degCand 65 RH

Eaverage = 904 Nmm2fm = 40 Nmm2

ENVIRONMENTAL CHARACTERISTICS

28

VESTAreg ECO-MATERIAL

VESTAreg (Vegetal Ecological Stable Timber

Advantage) is an innovative and eco-friendly compound

with exceptional properties It was developed by

NEOCOreg NEOLIFEreglsquos Research Centre specialising in

green technologies in partnership with European experts

EXCEPTIONAL WOOD FIBER CONTENTVESTAreg revolutionises eco-materials and the design of

environmental solutions for construction projects and the

landscaping of outside spaces It finally brings a response

to the architects landscapers and design officesrsquo

demands working on eco-construction and sustainable

development projects

ECO-FRIENDLYThe wood fibres contained in VESTAreg come exclusively

from sawmills offcuts the wood coming from sustainably

managed European forests The production of our material

does not require the cutting of any trees and does not use treated wood from recycled pallets Moreover

NEOLIFE does not use any toxic additives in the production process of the material

VESTAreg is 100 recyclable with a perfect traceability it only contains virgin substances (no recycled

components for which establishing a traceability is impossible)

CLEANDoes not contain solvents adhesives or phthalates and does not generate

toxic emissions

STABLE AND RESISTANTVESTAreg fibres benefit from a thermal treatment which provides hydrophobic properties to the material The

formula reinforced with mineral resin lignin and antioxidants enables a remarkable mechanical resistance as

well as an outstanding design

The mineral pigments also offer a strong resistance to UV rays making the colours more durable whatever the

exposure

SOURCE

Raw material VESTAreg

X-FIRE is highly fire-resistant Wood fibres coming from sustainably managed European forests

Board Production France

COMPOSITIONby Volume 75 wood fibres mineral oil mineral salts mineral pigments

PHYSICAL PROPERTIES

Mass sqm COVER 6 195 kgmsup2 COVER 14 165 kgmsup2

Density 1500 kgm3

Parasite resistance Equivalent to use class 4 No development of fungal rot mosses or mould Insect-resistant including termites

Surface appearance Micro-striated surface splinter free blisters or flakes off Maintenance-free

Scratches resistance Equivalent to natural wood - Brushing possible without discolouration

Thermal inertia Low thermal inertia due to the high wood fibres content

ENVIRONMENTAL PROPERTIES

Recycling 100 recyclable 75 renewable and combustible (75 biomass)

Toxic substances Contains no toxic or dangerous products (according to Reach Regulation EC19072006)

Chemical fire retardant substance None

Solvents None

Heavy metals None lead-and mercury-free stabilization

Phthalates adhesives None

Formaldehydes and VOCs Lower than or equal to natural wood

VESTAreg REINFORCED WOOD FIBER

VESTA X-FIRE

ENVIRONMENTAL PRODUCT DECLARATION

1 - Values describing the environmental impacts

Owner of the declaration NEOLIFE Editor BUREAU VERITAS CODDE Declaration reference DEP_NEOLIFE_COVER_201507

Publication 10072015 Validity 10072020

Complies with the standard ISO 14025 NF EN 15804+A1 And itrsquos national addendum X P01-064CN

Environmental Declaration of the COVER productavailable on request

ENVIRONMENTAL PRODUCT DECLARATION

2 ndash Values describing the use of primary energetic sources other resources and water

3 ndash Complementary values describing the outflows

FURTHER DETAILS

33

TECHNICAL DESCRIPTION

French accreditaion type laquo Avis Technique Expeacuterimental de Type A raquo issued by CSTB (France)

Ndeg2278 ndash Available at httpevaluationcstbfrrechercherproduits-evaluesprestations=atex

VESTA Reinforced Wood Fiber cladding containing at least 75 wood fibres

Boards with a slatted aspect featuring 6 cm or 14 cm ribs

Fire rating with natural mineral salts following EN 13501-12007

COVER 6 B-s3-d0 minimum

COVER 14 B-s3-d0 minimum

Invisible fixing with stainless steel hooks screwed into wood or metal battens

Fast and accurate fitting thanks to the interlocking board system

Outside corners catered for by using 45deg miter cuts or aluminium corner profile

Dimensional stability of maximum 2mm m over ∆80degC

rot-proof not sensitive to moss and mould

Insect-resistant termites included

Stable colors after natural patina is acquired

Contact us to get the full technical specification sheet

CONTACT

CAUTION

This technical sheet is associated with the technical installation guide of CLAD claddingboard available at wwwneolife-solutionscom

NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters

disposal for any clarifications concerning the installation procedure of its products

The specifications and recommendations given in the installation guide are not a

substitute to regulations concerning safety environment and professional regulatory

dispositions

All instructions concerning the installation of our cladding are to be followed

Assembly errors are not covered by the NEOLIFEreg guarantee

An approved fitter shall be able to assess the construction conformity to the local

professional installation guidelines

304 Route Nationale 6 ndash Celtic Parc Bacirctiment Avalon II - 69760 Limonest FranceTel +33 (0)4 78 25 63 08 ndash Fax +33 (0)4 72 29 29 47

wwwneolife-solutionscom

Page 28: COVER 6 & 14 CLADDING · 2020. 11. 3. · 60 cm centre-to-centre spacing 10 / m ... sill and causes stains onto the cladding after raining WINDOW SILL Advice : Make a window sill

ENVIRONMENTAL CHARACTERISTICS

28

VESTAreg ECO-MATERIAL

VESTAreg (Vegetal Ecological Stable Timber

Advantage) is an innovative and eco-friendly compound

with exceptional properties It was developed by

NEOCOreg NEOLIFEreglsquos Research Centre specialising in

green technologies in partnership with European experts

EXCEPTIONAL WOOD FIBER CONTENTVESTAreg revolutionises eco-materials and the design of

environmental solutions for construction projects and the

landscaping of outside spaces It finally brings a response

to the architects landscapers and design officesrsquo

demands working on eco-construction and sustainable

development projects

ECO-FRIENDLYThe wood fibres contained in VESTAreg come exclusively

from sawmills offcuts the wood coming from sustainably

managed European forests The production of our material

does not require the cutting of any trees and does not use treated wood from recycled pallets Moreover

NEOLIFE does not use any toxic additives in the production process of the material

VESTAreg is 100 recyclable with a perfect traceability it only contains virgin substances (no recycled

components for which establishing a traceability is impossible)

CLEANDoes not contain solvents adhesives or phthalates and does not generate

toxic emissions

STABLE AND RESISTANTVESTAreg fibres benefit from a thermal treatment which provides hydrophobic properties to the material The

formula reinforced with mineral resin lignin and antioxidants enables a remarkable mechanical resistance as

well as an outstanding design

The mineral pigments also offer a strong resistance to UV rays making the colours more durable whatever the

exposure

SOURCE

Raw material VESTAreg

X-FIRE is highly fire-resistant Wood fibres coming from sustainably managed European forests

Board Production France

COMPOSITIONby Volume 75 wood fibres mineral oil mineral salts mineral pigments

PHYSICAL PROPERTIES

Mass sqm COVER 6 195 kgmsup2 COVER 14 165 kgmsup2

Density 1500 kgm3

Parasite resistance Equivalent to use class 4 No development of fungal rot mosses or mould Insect-resistant including termites

Surface appearance Micro-striated surface splinter free blisters or flakes off Maintenance-free

Scratches resistance Equivalent to natural wood - Brushing possible without discolouration

Thermal inertia Low thermal inertia due to the high wood fibres content

ENVIRONMENTAL PROPERTIES

Recycling 100 recyclable 75 renewable and combustible (75 biomass)

Toxic substances Contains no toxic or dangerous products (according to Reach Regulation EC19072006)

Chemical fire retardant substance None

Solvents None

Heavy metals None lead-and mercury-free stabilization

Phthalates adhesives None

Formaldehydes and VOCs Lower than or equal to natural wood

VESTAreg REINFORCED WOOD FIBER

VESTA X-FIRE

ENVIRONMENTAL PRODUCT DECLARATION

1 - Values describing the environmental impacts

Owner of the declaration NEOLIFE Editor BUREAU VERITAS CODDE Declaration reference DEP_NEOLIFE_COVER_201507

Publication 10072015 Validity 10072020

Complies with the standard ISO 14025 NF EN 15804+A1 And itrsquos national addendum X P01-064CN

Environmental Declaration of the COVER productavailable on request

ENVIRONMENTAL PRODUCT DECLARATION

2 ndash Values describing the use of primary energetic sources other resources and water

3 ndash Complementary values describing the outflows

FURTHER DETAILS

33

TECHNICAL DESCRIPTION

French accreditaion type laquo Avis Technique Expeacuterimental de Type A raquo issued by CSTB (France)

Ndeg2278 ndash Available at httpevaluationcstbfrrechercherproduits-evaluesprestations=atex

VESTA Reinforced Wood Fiber cladding containing at least 75 wood fibres

Boards with a slatted aspect featuring 6 cm or 14 cm ribs

Fire rating with natural mineral salts following EN 13501-12007

COVER 6 B-s3-d0 minimum

COVER 14 B-s3-d0 minimum

Invisible fixing with stainless steel hooks screwed into wood or metal battens

Fast and accurate fitting thanks to the interlocking board system

Outside corners catered for by using 45deg miter cuts or aluminium corner profile

Dimensional stability of maximum 2mm m over ∆80degC

rot-proof not sensitive to moss and mould

Insect-resistant termites included

Stable colors after natural patina is acquired

Contact us to get the full technical specification sheet

CONTACT

CAUTION

This technical sheet is associated with the technical installation guide of CLAD claddingboard available at wwwneolife-solutionscom

NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters

disposal for any clarifications concerning the installation procedure of its products

The specifications and recommendations given in the installation guide are not a

substitute to regulations concerning safety environment and professional regulatory

dispositions

All instructions concerning the installation of our cladding are to be followed

Assembly errors are not covered by the NEOLIFEreg guarantee

An approved fitter shall be able to assess the construction conformity to the local

professional installation guidelines

304 Route Nationale 6 ndash Celtic Parc Bacirctiment Avalon II - 69760 Limonest FranceTel +33 (0)4 78 25 63 08 ndash Fax +33 (0)4 72 29 29 47

wwwneolife-solutionscom

Page 29: COVER 6 & 14 CLADDING · 2020. 11. 3. · 60 cm centre-to-centre spacing 10 / m ... sill and causes stains onto the cladding after raining WINDOW SILL Advice : Make a window sill

VESTAreg ECO-MATERIAL

VESTAreg (Vegetal Ecological Stable Timber

Advantage) is an innovative and eco-friendly compound

with exceptional properties It was developed by

NEOCOreg NEOLIFEreglsquos Research Centre specialising in

green technologies in partnership with European experts

EXCEPTIONAL WOOD FIBER CONTENTVESTAreg revolutionises eco-materials and the design of

environmental solutions for construction projects and the

landscaping of outside spaces It finally brings a response

to the architects landscapers and design officesrsquo

demands working on eco-construction and sustainable

development projects

ECO-FRIENDLYThe wood fibres contained in VESTAreg come exclusively

from sawmills offcuts the wood coming from sustainably

managed European forests The production of our material

does not require the cutting of any trees and does not use treated wood from recycled pallets Moreover

NEOLIFE does not use any toxic additives in the production process of the material

VESTAreg is 100 recyclable with a perfect traceability it only contains virgin substances (no recycled

components for which establishing a traceability is impossible)

CLEANDoes not contain solvents adhesives or phthalates and does not generate

toxic emissions

STABLE AND RESISTANTVESTAreg fibres benefit from a thermal treatment which provides hydrophobic properties to the material The

formula reinforced with mineral resin lignin and antioxidants enables a remarkable mechanical resistance as

well as an outstanding design

The mineral pigments also offer a strong resistance to UV rays making the colours more durable whatever the

exposure

SOURCE

Raw material VESTAreg

X-FIRE is highly fire-resistant Wood fibres coming from sustainably managed European forests

Board Production France

COMPOSITIONby Volume 75 wood fibres mineral oil mineral salts mineral pigments

PHYSICAL PROPERTIES

Mass sqm COVER 6 195 kgmsup2 COVER 14 165 kgmsup2

Density 1500 kgm3

Parasite resistance Equivalent to use class 4 No development of fungal rot mosses or mould Insect-resistant including termites

Surface appearance Micro-striated surface splinter free blisters or flakes off Maintenance-free

Scratches resistance Equivalent to natural wood - Brushing possible without discolouration

Thermal inertia Low thermal inertia due to the high wood fibres content

ENVIRONMENTAL PROPERTIES

Recycling 100 recyclable 75 renewable and combustible (75 biomass)

Toxic substances Contains no toxic or dangerous products (according to Reach Regulation EC19072006)

Chemical fire retardant substance None

Solvents None

Heavy metals None lead-and mercury-free stabilization

Phthalates adhesives None

Formaldehydes and VOCs Lower than or equal to natural wood

VESTAreg REINFORCED WOOD FIBER

VESTA X-FIRE

ENVIRONMENTAL PRODUCT DECLARATION

1 - Values describing the environmental impacts

Owner of the declaration NEOLIFE Editor BUREAU VERITAS CODDE Declaration reference DEP_NEOLIFE_COVER_201507

Publication 10072015 Validity 10072020

Complies with the standard ISO 14025 NF EN 15804+A1 And itrsquos national addendum X P01-064CN

Environmental Declaration of the COVER productavailable on request

ENVIRONMENTAL PRODUCT DECLARATION

2 ndash Values describing the use of primary energetic sources other resources and water

3 ndash Complementary values describing the outflows

FURTHER DETAILS

33

TECHNICAL DESCRIPTION

French accreditaion type laquo Avis Technique Expeacuterimental de Type A raquo issued by CSTB (France)

Ndeg2278 ndash Available at httpevaluationcstbfrrechercherproduits-evaluesprestations=atex

VESTA Reinforced Wood Fiber cladding containing at least 75 wood fibres

Boards with a slatted aspect featuring 6 cm or 14 cm ribs

Fire rating with natural mineral salts following EN 13501-12007

COVER 6 B-s3-d0 minimum

COVER 14 B-s3-d0 minimum

Invisible fixing with stainless steel hooks screwed into wood or metal battens

Fast and accurate fitting thanks to the interlocking board system

Outside corners catered for by using 45deg miter cuts or aluminium corner profile

Dimensional stability of maximum 2mm m over ∆80degC

rot-proof not sensitive to moss and mould

Insect-resistant termites included

Stable colors after natural patina is acquired

Contact us to get the full technical specification sheet

CONTACT

CAUTION

This technical sheet is associated with the technical installation guide of CLAD claddingboard available at wwwneolife-solutionscom

NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters

disposal for any clarifications concerning the installation procedure of its products

The specifications and recommendations given in the installation guide are not a

substitute to regulations concerning safety environment and professional regulatory

dispositions

All instructions concerning the installation of our cladding are to be followed

Assembly errors are not covered by the NEOLIFEreg guarantee

An approved fitter shall be able to assess the construction conformity to the local

professional installation guidelines

304 Route Nationale 6 ndash Celtic Parc Bacirctiment Avalon II - 69760 Limonest FranceTel +33 (0)4 78 25 63 08 ndash Fax +33 (0)4 72 29 29 47

wwwneolife-solutionscom

Page 30: COVER 6 & 14 CLADDING · 2020. 11. 3. · 60 cm centre-to-centre spacing 10 / m ... sill and causes stains onto the cladding after raining WINDOW SILL Advice : Make a window sill

SOURCE

Raw material VESTAreg

X-FIRE is highly fire-resistant Wood fibres coming from sustainably managed European forests

Board Production France

COMPOSITIONby Volume 75 wood fibres mineral oil mineral salts mineral pigments

PHYSICAL PROPERTIES

Mass sqm COVER 6 195 kgmsup2 COVER 14 165 kgmsup2

Density 1500 kgm3

Parasite resistance Equivalent to use class 4 No development of fungal rot mosses or mould Insect-resistant including termites

Surface appearance Micro-striated surface splinter free blisters or flakes off Maintenance-free

Scratches resistance Equivalent to natural wood - Brushing possible without discolouration

Thermal inertia Low thermal inertia due to the high wood fibres content

ENVIRONMENTAL PROPERTIES

Recycling 100 recyclable 75 renewable and combustible (75 biomass)

Toxic substances Contains no toxic or dangerous products (according to Reach Regulation EC19072006)

Chemical fire retardant substance None

Solvents None

Heavy metals None lead-and mercury-free stabilization

Phthalates adhesives None

Formaldehydes and VOCs Lower than or equal to natural wood

VESTAreg REINFORCED WOOD FIBER

VESTA X-FIRE

ENVIRONMENTAL PRODUCT DECLARATION

1 - Values describing the environmental impacts

Owner of the declaration NEOLIFE Editor BUREAU VERITAS CODDE Declaration reference DEP_NEOLIFE_COVER_201507

Publication 10072015 Validity 10072020

Complies with the standard ISO 14025 NF EN 15804+A1 And itrsquos national addendum X P01-064CN

Environmental Declaration of the COVER productavailable on request

ENVIRONMENTAL PRODUCT DECLARATION

2 ndash Values describing the use of primary energetic sources other resources and water

3 ndash Complementary values describing the outflows

FURTHER DETAILS

33

TECHNICAL DESCRIPTION

French accreditaion type laquo Avis Technique Expeacuterimental de Type A raquo issued by CSTB (France)

Ndeg2278 ndash Available at httpevaluationcstbfrrechercherproduits-evaluesprestations=atex

VESTA Reinforced Wood Fiber cladding containing at least 75 wood fibres

Boards with a slatted aspect featuring 6 cm or 14 cm ribs

Fire rating with natural mineral salts following EN 13501-12007

COVER 6 B-s3-d0 minimum

COVER 14 B-s3-d0 minimum

Invisible fixing with stainless steel hooks screwed into wood or metal battens

Fast and accurate fitting thanks to the interlocking board system

Outside corners catered for by using 45deg miter cuts or aluminium corner profile

Dimensional stability of maximum 2mm m over ∆80degC

rot-proof not sensitive to moss and mould

Insect-resistant termites included

Stable colors after natural patina is acquired

Contact us to get the full technical specification sheet

CONTACT

CAUTION

This technical sheet is associated with the technical installation guide of CLAD claddingboard available at wwwneolife-solutionscom

NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters

disposal for any clarifications concerning the installation procedure of its products

The specifications and recommendations given in the installation guide are not a

substitute to regulations concerning safety environment and professional regulatory

dispositions

All instructions concerning the installation of our cladding are to be followed

Assembly errors are not covered by the NEOLIFEreg guarantee

An approved fitter shall be able to assess the construction conformity to the local

professional installation guidelines

304 Route Nationale 6 ndash Celtic Parc Bacirctiment Avalon II - 69760 Limonest FranceTel +33 (0)4 78 25 63 08 ndash Fax +33 (0)4 72 29 29 47

wwwneolife-solutionscom

Page 31: COVER 6 & 14 CLADDING · 2020. 11. 3. · 60 cm centre-to-centre spacing 10 / m ... sill and causes stains onto the cladding after raining WINDOW SILL Advice : Make a window sill

ENVIRONMENTAL PRODUCT DECLARATION

1 - Values describing the environmental impacts

Owner of the declaration NEOLIFE Editor BUREAU VERITAS CODDE Declaration reference DEP_NEOLIFE_COVER_201507

Publication 10072015 Validity 10072020

Complies with the standard ISO 14025 NF EN 15804+A1 And itrsquos national addendum X P01-064CN

Environmental Declaration of the COVER productavailable on request

ENVIRONMENTAL PRODUCT DECLARATION

2 ndash Values describing the use of primary energetic sources other resources and water

3 ndash Complementary values describing the outflows

FURTHER DETAILS

33

TECHNICAL DESCRIPTION

French accreditaion type laquo Avis Technique Expeacuterimental de Type A raquo issued by CSTB (France)

Ndeg2278 ndash Available at httpevaluationcstbfrrechercherproduits-evaluesprestations=atex

VESTA Reinforced Wood Fiber cladding containing at least 75 wood fibres

Boards with a slatted aspect featuring 6 cm or 14 cm ribs

Fire rating with natural mineral salts following EN 13501-12007

COVER 6 B-s3-d0 minimum

COVER 14 B-s3-d0 minimum

Invisible fixing with stainless steel hooks screwed into wood or metal battens

Fast and accurate fitting thanks to the interlocking board system

Outside corners catered for by using 45deg miter cuts or aluminium corner profile

Dimensional stability of maximum 2mm m over ∆80degC

rot-proof not sensitive to moss and mould

Insect-resistant termites included

Stable colors after natural patina is acquired

Contact us to get the full technical specification sheet

CONTACT

CAUTION

This technical sheet is associated with the technical installation guide of CLAD claddingboard available at wwwneolife-solutionscom

NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters

disposal for any clarifications concerning the installation procedure of its products

The specifications and recommendations given in the installation guide are not a

substitute to regulations concerning safety environment and professional regulatory

dispositions

All instructions concerning the installation of our cladding are to be followed

Assembly errors are not covered by the NEOLIFEreg guarantee

An approved fitter shall be able to assess the construction conformity to the local

professional installation guidelines

304 Route Nationale 6 ndash Celtic Parc Bacirctiment Avalon II - 69760 Limonest FranceTel +33 (0)4 78 25 63 08 ndash Fax +33 (0)4 72 29 29 47

wwwneolife-solutionscom

Page 32: COVER 6 & 14 CLADDING · 2020. 11. 3. · 60 cm centre-to-centre spacing 10 / m ... sill and causes stains onto the cladding after raining WINDOW SILL Advice : Make a window sill

ENVIRONMENTAL PRODUCT DECLARATION

2 ndash Values describing the use of primary energetic sources other resources and water

3 ndash Complementary values describing the outflows

FURTHER DETAILS

33

TECHNICAL DESCRIPTION

French accreditaion type laquo Avis Technique Expeacuterimental de Type A raquo issued by CSTB (France)

Ndeg2278 ndash Available at httpevaluationcstbfrrechercherproduits-evaluesprestations=atex

VESTA Reinforced Wood Fiber cladding containing at least 75 wood fibres

Boards with a slatted aspect featuring 6 cm or 14 cm ribs

Fire rating with natural mineral salts following EN 13501-12007

COVER 6 B-s3-d0 minimum

COVER 14 B-s3-d0 minimum

Invisible fixing with stainless steel hooks screwed into wood or metal battens

Fast and accurate fitting thanks to the interlocking board system

Outside corners catered for by using 45deg miter cuts or aluminium corner profile

Dimensional stability of maximum 2mm m over ∆80degC

rot-proof not sensitive to moss and mould

Insect-resistant termites included

Stable colors after natural patina is acquired

Contact us to get the full technical specification sheet

CONTACT

CAUTION

This technical sheet is associated with the technical installation guide of CLAD claddingboard available at wwwneolife-solutionscom

NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters

disposal for any clarifications concerning the installation procedure of its products

The specifications and recommendations given in the installation guide are not a

substitute to regulations concerning safety environment and professional regulatory

dispositions

All instructions concerning the installation of our cladding are to be followed

Assembly errors are not covered by the NEOLIFEreg guarantee

An approved fitter shall be able to assess the construction conformity to the local

professional installation guidelines

304 Route Nationale 6 ndash Celtic Parc Bacirctiment Avalon II - 69760 Limonest FranceTel +33 (0)4 78 25 63 08 ndash Fax +33 (0)4 72 29 29 47

wwwneolife-solutionscom

Page 33: COVER 6 & 14 CLADDING · 2020. 11. 3. · 60 cm centre-to-centre spacing 10 / m ... sill and causes stains onto the cladding after raining WINDOW SILL Advice : Make a window sill

FURTHER DETAILS

33

TECHNICAL DESCRIPTION

French accreditaion type laquo Avis Technique Expeacuterimental de Type A raquo issued by CSTB (France)

Ndeg2278 ndash Available at httpevaluationcstbfrrechercherproduits-evaluesprestations=atex

VESTA Reinforced Wood Fiber cladding containing at least 75 wood fibres

Boards with a slatted aspect featuring 6 cm or 14 cm ribs

Fire rating with natural mineral salts following EN 13501-12007

COVER 6 B-s3-d0 minimum

COVER 14 B-s3-d0 minimum

Invisible fixing with stainless steel hooks screwed into wood or metal battens

Fast and accurate fitting thanks to the interlocking board system

Outside corners catered for by using 45deg miter cuts or aluminium corner profile

Dimensional stability of maximum 2mm m over ∆80degC

rot-proof not sensitive to moss and mould

Insect-resistant termites included

Stable colors after natural patina is acquired

Contact us to get the full technical specification sheet

CONTACT

CAUTION

This technical sheet is associated with the technical installation guide of CLAD claddingboard available at wwwneolife-solutionscom

NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters

disposal for any clarifications concerning the installation procedure of its products

The specifications and recommendations given in the installation guide are not a

substitute to regulations concerning safety environment and professional regulatory

dispositions

All instructions concerning the installation of our cladding are to be followed

Assembly errors are not covered by the NEOLIFEreg guarantee

An approved fitter shall be able to assess the construction conformity to the local

professional installation guidelines

304 Route Nationale 6 ndash Celtic Parc Bacirctiment Avalon II - 69760 Limonest FranceTel +33 (0)4 78 25 63 08 ndash Fax +33 (0)4 72 29 29 47

wwwneolife-solutionscom

Page 34: COVER 6 & 14 CLADDING · 2020. 11. 3. · 60 cm centre-to-centre spacing 10 / m ... sill and causes stains onto the cladding after raining WINDOW SILL Advice : Make a window sill

TECHNICAL DESCRIPTION

French accreditaion type laquo Avis Technique Expeacuterimental de Type A raquo issued by CSTB (France)

Ndeg2278 ndash Available at httpevaluationcstbfrrechercherproduits-evaluesprestations=atex

VESTA Reinforced Wood Fiber cladding containing at least 75 wood fibres

Boards with a slatted aspect featuring 6 cm or 14 cm ribs

Fire rating with natural mineral salts following EN 13501-12007

COVER 6 B-s3-d0 minimum

COVER 14 B-s3-d0 minimum

Invisible fixing with stainless steel hooks screwed into wood or metal battens

Fast and accurate fitting thanks to the interlocking board system

Outside corners catered for by using 45deg miter cuts or aluminium corner profile

Dimensional stability of maximum 2mm m over ∆80degC

rot-proof not sensitive to moss and mould

Insect-resistant termites included

Stable colors after natural patina is acquired

Contact us to get the full technical specification sheet

CONTACT

CAUTION

This technical sheet is associated with the technical installation guide of CLAD claddingboard available at wwwneolife-solutionscom

NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters

disposal for any clarifications concerning the installation procedure of its products

The specifications and recommendations given in the installation guide are not a

substitute to regulations concerning safety environment and professional regulatory

dispositions

All instructions concerning the installation of our cladding are to be followed

Assembly errors are not covered by the NEOLIFEreg guarantee

An approved fitter shall be able to assess the construction conformity to the local

professional installation guidelines

304 Route Nationale 6 ndash Celtic Parc Bacirctiment Avalon II - 69760 Limonest FranceTel +33 (0)4 78 25 63 08 ndash Fax +33 (0)4 72 29 29 47

wwwneolife-solutionscom

Page 35: COVER 6 & 14 CLADDING · 2020. 11. 3. · 60 cm centre-to-centre spacing 10 / m ... sill and causes stains onto the cladding after raining WINDOW SILL Advice : Make a window sill

CONTACT

CAUTION

This technical sheet is associated with the technical installation guide of CLAD claddingboard available at wwwneolife-solutionscom

NEOLIFEreg recommends to read the installation manual carefully and remains at the fitters

disposal for any clarifications concerning the installation procedure of its products

The specifications and recommendations given in the installation guide are not a

substitute to regulations concerning safety environment and professional regulatory

dispositions

All instructions concerning the installation of our cladding are to be followed

Assembly errors are not covered by the NEOLIFEreg guarantee

An approved fitter shall be able to assess the construction conformity to the local

professional installation guidelines

304 Route Nationale 6 ndash Celtic Parc Bacirctiment Avalon II - 69760 Limonest FranceTel +33 (0)4 78 25 63 08 ndash Fax +33 (0)4 72 29 29 47