Abaqus Technology Brief Summary Background Analysis Approach Coupled Electromagnetic and Fluid-Structure Interaction Analysis of a Solenoid Valve Key Abaqus Features and Benefits High Reynolds number incompressible viscous fluid flow in Abaqus/CFD Arbitrary Lagrangian-Eulerian framework with deforming meshes in Abaqus/CFD Boundary layer meshing in Abaqus/CAE Electromagnetic analysis to determine magnetic fields induced by current flow Co-simulation of valve dynamics using Abaqus/ Standard and Abaqus/CFD Sequentially coupled electromagnetic/fluid- structure interaction analysis with user subrou- tine UAMP Unified pre- and post-processing in Abaqus/CAE Orifice Inflow Outflow Plunger Solenoid coil Solenoid core Spring
7
Embed
Coupled Electromagnetic and Fluid-Structure Interaction ...
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Abaqus Technology Brief
Summary
Background
Analysis Approach
Coupled Electromagnetic and Fluid-Structure Interaction Analysis
of a Solenoid Valve
Key Abaqus Features and Benefits
High Reynolds number incompressible viscous fluid flow in Abaqus/CFD
Arbitrary Lagrangian-Eulerian framework with deforming meshes in Abaqus/CFD
Boundary layer meshing in Abaqus/CAE
Electromagnetic analysis to determine magnetic fields induced by current flow
Co-simulation of valve dynamics using Abaqus/Standard and Abaqus/CFD
Sequentially coupled electromagnetic/fluid-structure interaction analysis with user subrou-tine UAMP
Unified pre- and post-processing in Abaqus/CAE
Orifice
Inflow Outflow
Plunger
Solenoid coil Solenoid core
Spring
u48
Typewritten Text
u48
Typewritten Text
u48
Typewritten Text
u48
Typewritten Text
Visit the Resource Center for more SIMULIA customer papers
Electromagnetic Analysis Obtain EM force as a function of elec-
tric current and plunger location
Perform a parametric study to gener-ate the data
Python scripting and Isight facilitate the parametric study
EM analysis in Abaqus/Standard
FSI Analysis Co-simulation between fluid and
structural domains
Co-simulation engine in Abaqus per-forms a conservative physics-based mapping between dissimilar fluid and structural meshes
Fluid Analysis Abaqus/CFD
Viscous incom-pressible fluid dy-namics
High Reynolds number turbulent flow
Arbitrary Lagran-gian-Eulerian (ALE) method with mesh deformation
Rigid Body Dynamics
Abaqus/Standard
EM Force Sensor output on
plunger displace-ment
EM force applied through user sub-routine UAMP
Plunger
Solenoid coil Solenoid core
u48
Typewritten Text
3
Results
FSI Analysis
Inlet
Outlet
Valve seat
Plunger
Orifice
4
τ
τ
Rigid plunger
Spring & dashpot Plunger reference point
5
Results and discussion of the FSI Analysis