Lamont family Trust T/as Mob 0428 632247 Email: [email protected]Ph/fax 02 44 740393 WEB: www.anotherroom.com.au ABN. 45103119631 COUNCIL INFORMATION BOOK The information contained within this information package remains the sole intellectual property of Grant Lamont T/AS Another Room. All uses of this information other than in connection with Another Room products is expressly PROHIBITED with out consent of Another Room. Copying of information for consent authority purposes or in connection of sales of Another Room products is permitted. All products interlectual property referenced in these documents remain the sole property of their individual owners / companies and Grant Lamont T/AS Another Room does not take responsibility for any error or in accuracy in technical details provided from said companies.
23
Embed
COUNCIL INFORMATION BOOK - Another Room · 2017. 3. 23. · colors panels are available in 3 standard colors, 4 non standard colors standard surfmist (off white), pale eucalypt (mist
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
The information contained within this information package remains the sole intellectual property of Grant Lamont T/AS Another Room. All uses of this information other than in connection with Another Room products is expressly PROHIBITED with out consent of Another Room. Copying of information for consent authority purposes or in connection of sales of Another Room products is permitted. All products interlectual property referenced in these documents remain the sole property of their individual owners / companies and Grant Lamont T/AS Another Room does not take responsibility for any error or in accuracy in technical details provided from said companies.
BUILDING SKID CONSISTS OF TWO HIGH QUALITY GALVANIZED CHANNELS WITH GALVANIZED BOX SECTION FLOORING JOISTS INSTALLED TO AUSTRALIAN BUILDING STANDARD SPACINGS, FULLY WELDED AND CORROSION PROTECTED BRACED FOR STRUCTURAL INTEGRITY, DESIGN FOR STRENGTH, LONG LIFE AND NUMEROUS RELOCATION'S.
FLOOR
FLOOR CONSISTS OF 19 MM THICK GREEN TONGUE PARTICLE FLOOR SHEETS TERMITE TREATED AS USED IN GENERAL HOUSE CONSTRUCTION ( NOT 12 MM PLY AS GENERALLY USED) SCREWED TO FLOOR JOISTS INSTALLED UP INSIDE OF BUILDING PANELS TO GUARANTEE WEATHER PROOFING.
WALLS & CEILING
BUILDING WALLS & CEILING ARE CONSTRUCTED FROM HIGH QUALITY COOL ROOM INSULATION ( EPS) PANELS (UTILIZING BLUE SCOPE 0.6 MM CRP PANEL SKINS) MAXIMIZING THE USE OF THEIR EXCELLENT THERMAL AND NOISE INSULATION PROPERTIES TO CREATE A CONTROLLED ENVIRONMENT. THE EPS PANELS ARE AN AUSTRALIAN MADE PRODUCT MANUFACTURED IN SYDNEY UTILIZING THE BEST TECHNOLOGIES, AUSTRALIAN EXPANDED CFC FREE POLYSTYRENE AND HIGH QUALITY AUSTRALIAN ANTICORROSIVE BLUE SCOPE STEEL COLOR BOND SHEETING DEVELOPED FOR ARDUOUS INDUSTRY CONDITIONS. EPS PANELS ARE FLAME RETARDENT, SELF EXTINGUISHING AND HAVE BEEN TESTED BY CSIRO TO BE LESS TOXIC THAN NORMAL CONSTRUCTION METHODS DURING COMBUSTION. THEY HAVE NO NUTRIENT VALUE AND DO NOT SUPPORT BACTERIAL GROWTH, ATTRACT ANTS, TERMITES OR RODENTS
COLORS
PANELS ARE AVAILABLE IN 3 STANDARD COLORS, 4 NON STANDARD COLORS
STANDARD SURFMIST (OFF WHITE), PALE EUCALYPT (MIST GREEN) & PAPERBARK
(MERINO)
NON STANDARD CLASSIC CREAM, SHALE GREY, DUNE & FASCADE, CITI METALLIC
ROOF
BUILDINGS ARE OVER ROOFED WITH BLUE SCOPE COLOR BOND CORRUGATED ROOFING , FITTED WITH GUTTERS AND DRAINPIPES IN YOUR CHOICE OF COLORS FROM THE AVAILABLE BLUE SCOPE COLOR MATRIX FOR COLOR BOND WITH A 5 DEGREE CONCAVE PITCH.
DOORS & WINDOWS
BUILDINGS FITTED WITH HIGH QUALITY SLIDING WINDOWS AND DOORS INCLUDING SCREENS AVAILABLE IN YOUR CHOICE OF COLOR AS PER COLOR BOND COLORS (OPTIONAL PANEL DOORS AVAILABLE).
FLOORING
AVAILABLE WITH CHOICE OF LINO, CARPET OR CARPET WITH LINO INSERT ALONG WITH OPTION OF INDUSTRIAL LINO.
KITCHENS AVAILABLE WITH CUSTOM MADE KITCHENS AS REQUIRED USING QUALITY FLAT PACK KITS AND CUSTOM MADE BENCH TOPS.
ELECTRIC'S
BUILDING IS ENTIRELY PRE WIRED REQUIRING ONLY SITE CONNECTION BY QUALIFIED ELECTRICIAN INCLUDING SAFETY SWITCHES, 4 DOUBLE POWER POINTS, LIGHTS ETC., PRE WIRED FOR AIR CONDITIONING UNITS AND THEY CAN BE FITTED DURING CONSTRUCTION.
FOOTINGS & WIND RATINGS
ENGINEERED WIND CATEGORY RATING OF CATEGORY 2 (180 KM/HR PLUS (MUST BE INSTALLED AS PER RECOMMENDED FOOTING SPECIFICATIONS)). FOOTING DRAWINGS AND LOCATIONS SUPPLIED
BUILDING BENEFITS MINIMAL INTERRUPTION TO HOME LIFE DURING INSTALLATION EASILY INSTALLED BY ANY COMPETENT PERSON WINDOWS AND DOOR LAYOUT MAY BE LOCATED TO SUIT ALL REQUIREMENTS DUE TO TYPE OF PANEL CONSTRUCTION EASILY REMOVABLE AND RE SALE ABLE SIMPLE ANCHORING DESIGN WEATHER PROOF & ENERGY EFFICIENT EXCELLENT THERMAL AND NOISE PROPERTIES COST EFFECTIVE (PARTICULARLY WITH RESALE VALUE) AESTHETICALLY PLEASING EASILY ADAPTED OR DECORATED TO SUIT ALL TASTES/NEEDS FULLY WIRED REQUIRING A SIMPLE ELECTRICAL CONNECTION EASE OF DELIVERY AND INSTALLATION AS DESIGNED TO TRANSPORT ON TILT TRAYS OR TRUCK AND CRANE AS NECESSARY EXTREMELY LITE CONSIDERING STRENGTH AND SIZE MANUFACTURED USING THE BEST QUALITY PRODUCTS FULL INFORMATION PACKAGE TO ASSIST WITH COUNCIL REQUIREMENTS
POLYSTYRENE CORE BUTT JOINTSThe butt joints between the ends of the polystyrene core material have been made by way of finger jointing pro-viding a mechanical bond across the end faces of the core material.SURFACE PROFILES• The PPI Slip-joint® forms the edges of both skins with a male and female joint to either edge. Panels can be fin-ished flat or with a low profile of 0.75mm depth to either surface: • 100mm profile or • Silkline profile.
PRODUCT DESCRIPTIONPoly Panel Industries’ panels are 1200mm width stressed skin panels manufactured on an insulated panel produc-tion line. • Panel cores are self-extinguishing grade expanded polystyrene Class SL, as supplied by Poly Panel Indus-tries and bonded under pressure to BlueScope Steel Colorbond® pre-painted Galvabond or Zincalume base steel facings (using a two-part polyurethane adhesive). Thickness ranges with the EPS core material from 50 to 300mm in multiples of 25mm to suit thermal or structural requirements (conditions apply). • Panels are available in continuous lengths up to 18 metres (subject to transport facilities), manufactured to order and cut to the specified length.• Steel facings can range in thickness from 0.40mm to 0.60mm for either surface skin.• Standard finish is an oven-cured 25% Gloss level Per-magard™ White in Microban® for antibacterial protec-tion. There are other colours in the Colorbond® range subject to availability.THERMAL PERFORMANCE
SL Grade EPS
Panel Thickness (mm)
R value(m2K/W)
U factor(W/m2K)
50 1.32 0.76
75 1.97 0.51
100 2.63 0.38
150 3.95 0.25
200 5.26 0.19
250 6.58 0.15
300 7.90 0.13
SECTION PROPERTIESSection properties and mass for unit (1000mm) width of panel, together with the recommended maximum design skin stresses have been determined for panels of vary-ing panel thickness and these are shown below.
0.40mm Steel Skin
Thickness (mm)
Section Modulus(mm2)
Maximum Design Skin Stress (MPa)
Weight (kg/m2)
50 21230 65 7.7
75 32020 60 8.1
100 42800 50 8.4
150 64370 42 9.0
0.60mm Steel Skin
Thickness(mm)
SectionModulus(mm2)
MaximumDesign SkinStress (MPa)
Weight(kg/m2)
50 31590 48 10.9
75 47770 48 11.2
100 63940 48 11.6
150 96300 48 12.2
200 128660 48 12.9
250 161020 48 13.6
300 193380 48 14.4
POLY PANELEPS Core Insulated Panel
SPECIFICATIONS AT A GLANCECorePanel cores are fi re-resistant XFlam™ based on syntactic technol-ogy. XFlam™ comprises a composite blend of specifi c phenolic resins and various fi lling materials, manufactured to Australian standards. Steel skins are bonded to the core under pressure using a two-part thermosetting polyurethane adhesive.SkinsSheet thickness can range from 0.40mm to 0.60mm for either surface skin. Panel skins are available with a choice of steel:• Colorbond® Permagard™ steel, incorporating Microban® antibacterial technology in its coating to provide durable, food-safe performance that will not wash off . This steel is available in Permagard™ White only.• Colorbond® standard grade steel comes in a wide range of designer colours.• There are other skin materials available on request, including Stainless Steel, Aluminium and Printech™ printed steel.ColourThe many colours available in Colorbond® range from traditional to modern. For Prestige Applications there is Colorbond® Metalic steel.Generally, the lighter colours are preferred for EPS panel used externally, because they refl ect solar radiation. The various surfaces and colour choice can infl uence the price per square metre - our sales staff will gladly assist you in your selection.Dimensions• Width: 1200mm as a modular standard.• Thickness: 50 to 250mm in multiples of 25mm.• Length: Cut to order, a minimum length 1000mm to a maximum of 22000mm.Profi lesAvailable with a fl at surface fi nish or low profi le of 0.75mm depth to either surface: 100mm Rib profi le, 50mm Mesa Rib and Silkline.The Austral Slip-joint® is incorporated into the edges of both surface skins for easy installation.
THERMAL PERFORMANCE (XFlam™ core )
Panel Thickness (mm)
R value(m2K/W)
Weight(kg/m2)
50 1.61 12.7
75 2.42 13.7
100 3.23 14.6
150 4.84 16.5
200 6.45 18.4
250 8.06 20.3
Austral Insulation panel on display:Some of the various applications
for Austral Insulation laminated insulated panel are illustrated above:Residential dwellings, Public buildings and Refrigerated storage facilities.
Orders for panelAll panels are manufactured to order. Wall panel can be supplied with rebate ends for support to the ceiling or mitre edge for corner joints. Ceiling panel is square cut. Orders should state your requirements, including preferred colours and profi le.
Notes 1) The tabulated safe loads are recommended unfactored maximum nett loads. (In the assessment of the design loads, the designer should take into account the self weight of the panel). 2) Compliance with these recommendations will ensure that deflections do not exceed span/90. Where more severe deflection restrictions are required, specific testing of deflection characteristics is recom mended for the various span/thickness combinations. 3) A minimum design load of 0.5kN/m2 is recommended for general applications. Circumstances may require different design loading. 4) Where panels are continuous across a support, it is recommended that stress cuts be made across the inside (or cold side) steel skin adjacent to the supports to prevent buckling of the outer (warm side) skin at the support. Fixings should be provided on both sides of the stress cut. 5) The finger joints at the butt joints of the polystyrene core material occur every 5 metres. These provide a mechanical bond between the polystyrene core sheets. Adhesive bonding is not required.
Produced May 2009
POLY PANELEPS Core Insulated Panel
63489 PPI EPS Core Tech.indd 2 18/05/09 3:47 PM
1 of 2
GENERAL DESCRIPTION
COLORBOND® Insulation Panel steel, designedby BlueScope Steel Limited, specifically for themanufacture of sandwich panels for coolrooms.The product offers excellent formability coupledwith good durability.
TYPICAL USESCoolroom panels.
AUSTRALIAN STANDARDSubstrate – AS 1397Paint Coating – AS/NZS 2728:1997 Type 3
Please refer to current price list or BlueScope Steel Limited State Sales Office for availability of colours and dimensions.
Only light colours are available. Colour in the ‘L’ scale is greater than 50. The product is supplied with a nominal 25%(60º) gloss.
Protective film (CORSTRIP®) should be removed from the painted steel strip immediately on installation. Sunlight canincrease the adhesion of the protective film to the painted surface if left uncovered outside. Refer to brochure ‘The smartway to design, install and maintain COLORBOND® steel’.
LINE TESTED PROPERTIESProperty Measured By Test Method Results
EXPECTED PRODUCT SERVICE PERFORMANCEProperty Measured After Test Method Results
Resistance to colour change QUV (2000 hours) ASTM G53 ∆ E Hunterlab:Light colour: ≤6 units
Natural well washed ASTM D2244 ∆ E Hunterlab:exposure (10 years) Light colour: ≤6 units
Resistance to chalking QUV (1000 hours) ASTM G53 Rating: ≤4AS/NZS 1580 481.1.11(Method B)
Natural well washed AS/NZS 1580 481.1.11 Chalk rating: ≤4exposure (10 years) (Method B)
Resistance to corrosion Salt spray (500 hours) ASTM B117 Blister density: ≤2AS 2331.3.1 Blister size: ≤S2NCCA Tech. Bull. 5.4.6 Undercut from a score: ≤2mmAS/NZ 2728 (App. H3) No loss of adhesion
Kesternich (SO2) DIN 50018 Edge creep: <4mm(50 cycles) Blisters: nil
Resistance to humidity Cleveland (1000 hours) NCCA Tech. Bull. 5.4.5 Blister density: ≤2Blister size: ≤S2No loss of adhesion
Resistance to acids Exposure ASTM D1308 No discolouration(3.1.1) No blistering
Protective Film may be available on requestFinish Coat (Nominal 20µm)Universal Corrosion Inhibitive Primer (Nominal 5µm)Conversion Coating
Revision 6, November 2003This literature supersedes all previous issues
2 of 2
EXPECTED PRODUCT SERVICE PERFORMANCE (Cont.)Property Measured After Test Method Results
Resistance to solvents Exposure ASTM D1308 No discolouration(3.1.1) No blistering
Adhesion Natural well washed – No flaking or peelingexposure (10 years)
Resistance to fire Exposure AS/NZS 1530.3 Ignitability index:0 rating in scale of 0 -20Spread of flame index:0 rating in scale of 0 -10Heat evolved index:0 rating in scale of 0 -10Smoke evolved index:0 -1 rating in scale of 0 -10
Flexibility T - bend AS 2935 (App. E) Maximum 8T (no cracking)NCCA Tech. Bull. 4.2.8
Resistance to abrasion Taber Abraser – 1000g AS/NZS 1580 403.2 ≤20mg per 100 cyclesCS 10 wheels NCCA Tech. Bull. 4.2.5
Scratch AS/NZS 1580 Typically 2000g
NOTE
➀ Values quoted are for standard colours of COLORBOND® Insulation Panel steel under normal well washed conditions of exposure.
➁ Product may not be suitable if it is intended to use COLORBOND® Insulation Panel steel in an exterior application within1km of salt marine locations, severe industrial or abnormally corrosive environments, areas not washed by rain, or inapplications where it will be wholly or partly buried in the ground. Before purchase, you should check on suitabilitythrough contacting your nearest BlueScope Steel Limited Sales office for advice.
➂ COLORBOND® Insulation Panel steel has good resistance to accidental spillage of solvents such as methylated spirits,white spirit, mineral turpentine, toluene, trichloroethylene and dilute mineral acids and alkalis. However, all spillagesshould be immediately removed by water washing and drying.
➃ For most products, the metallurgical ageing process which is inherent in the paint stoving cycle will result in some loss ofductility compared with unpainted product. However, minimum strength levels designated by relevant standards will stillbe applicable.
➄ Improper storage or the use of non-approved roll-forming lubricants may adversely affect colour. Material which becomeswet while in stacks or bundles must be separated and dried (refer AS/NZS 2728 Appendix K).
➅ Customers should use product promptly (within 6 months) to avoid the possibility of storage related corrosion and aphenomena of galvanized coatings termed intergranular corrosion.
COLORBOND®, ZINCALUME® and CORSTRIP® are registered trade marks of BlueScope Steel Limited.
BlueScope is a trade mark of BlueScope Steel Limted.
Please ensure you have the current data sheet for this product as displayed at www.bluescopesteel.com.au
Please refer to current price list or BlueScope Steel Limited State Sales Office for availability of colours and dimensions.
The finish coat can, if required, be applied to both sides to provide a ‘double sided’ product. The product is supplied witha nominal 25% (60º) gloss.
The protective film (CORSTRIP®) should be removed from the painted steel strip immediately on installation. Sunlight canincrease adhesion of the protective film to the painted surface if left uncovered outside. Refer to brochure ‘ The smartway to design, install and maintain COLORBOND® steel .’
LINE TESTED PROPERTIESProperty Measured By Test Method Results
EXPECTED PRODUCT SERVICE PERFORMANCEProperty Measured After Test Method Results
Resistance to colour change QUV (2000 hours) ASTM G53 ∆ E Hunterlab:Intermediate colour:≤5 unit, eg Wheat
Natural well washed ASTM D2244 ∆ E Hunterlab:exposure (15 years) Light colour: ≤6 units
Int. colour: ≤9 unitsDark colour: ≤15 units
Resistance to chalking QUV (2000 hours) ASTM G53 Rating: ≤4AS/NZS 1580 481.1.11(Method B)
Natural well washed AS/NZS 1580 481.1.11 Chalk rating: ≤4exposure (10 years) (Method B)
Resistance to corrosion Salt spray (1000 hours) ASTM B117 Blister density: ≤2AS 2331.3.1 Blister size: ≤S2NCCA Tech. Bull. 5.4.6 Undercut from a score: ≤2mm
No loss of adhesion
Kesternich (SO2) DIN 50018 Edge creep: <4mm(50 cycles)
Resistance to humidity Cleveland (1000 hours) NCCA Tech. Bull. 5.4.5 Blister density: ≤2Blister size: ≤S2No loss of adhesion
Resistance to acids Exposure ASTM D1308 No discolouration(3.1.1) No blistering
GENERAL DESCRIPTION
COLORBOND® prepainted steel, specifically designed by BlueScope SteelLimited to provide a high durability,premier cladding and roofing materialfor general use.
GENERAL DESCRIPTION
Roofing and accessories, wall cladding, rain water goods.
AUSTRALIAN STANDARDSubstrate – AS 1397Paint Coating – AS/NZS 2728:1997 Type 3-4
Protective Film may be available on requestFinish Coat (Nominal 20µm)Universal Corrosion Inhibitive Primer (Nominal 5µm)Conversion Coating
Revision 7, November 2003This literature supersedes all previous issues
2 of 2
Property Measured After Test Method Results
Resistance to alkalis Exposure ASTM D1308 No discolouration(3.1.1) No blistering
Resistance to solvents Exposure ASTM D1308 No discolouration(3.1.1) No blistering
Adhesion Natural well washed – No flaking or peelingexposure (15 years)
Resistance to heat Exposure ASTM D2244 Colour change 100ºC continuous ∆ E Hunterlab: ≤3 units
Resistance to fire Exposure AS/NZS 1530.3 Ignitability index:0 rating in scale of 0 - 20Spread of flame index:0 rating in scale of 0 - 10Heat evolved index:0 rating in scale of 0 - 10Smoke evolved index:0 - 1 rating in scale of 0 - 10
Flexibility T - bend AS 2935 (App. E) Maximum 7T (no cracking)NCCA Tech. Bull. 4.2.8
Resistance to abrasion Taber Abraser - 1000g AS/NZS 1580 403.2 ≤20mg per 100 cyclesCS 10 wheels NCCA Tech. Bull. 4.2.5
Scratch AS/NZS 1580 403.1 Typically 2000g
NOTE
➀ For selection of the most appropriate COLORBOND® steel product refer to ‘Steel Roofing Products – Selection Guide TechnicalBulletin TB - 1a’, and ‘Steel Walling Products – Selection Guide Technical Bulletin TB - 1b’.
➁ Values quoted are for standard colours of COLORBOND® steel under normal well washed conditions of exposure. Product may notbe suitable if it is intended to use COLORBOND® steel in an exterior application within 1km of salt marine locations, severe industrialor abnormally corrosive environments, or in applications where it will be wholly or partly buried in the ground. Before purchase,you should check on suitability through contacting your nearest BlueScope Steel Limited Sales office for advice.
➂ COLORBOND® steel has good resistance to accidental spillage of solvents such as methylated spirits, white spirit, mineralturpentine, toluene, trichloroethylene and dilute mineral acids and alkalis. However, all spillages should be immediately removed bywater washing and drying.
➃ For most products, the metallurgical ageing process which is inherent in the paint stoving cycle will result in some loss of ductilitycompared with unpainted product. However, minimum strength levels designated by relevant standards will still be applicable.
➄ Improper storage or the use of non-approved roll-forming lubricants may adversely affect colour. Material which becomes wet whilein stacks or bundles must be separated and dried (refer AS/NZS 2728 Appendix K).
➅ The Backing coat is not recommended for exposure to direct sunlight. Where the reverse side will be exposed to direct sunlight, the“double sided” product is recommended.
➆ Definitions• Finish coat - the coating applied to the exposed surface of the prepainted coil or sheet which is expected
to meet the Performance Requirements.• Backing coat - a thin (pigmented or clear) coating applied to the reverse or unexposed surface of the
prepainted coil or sheet for the purpose of protection against damage to the topcoat duringshipment and storage. It also gives additional durability to the reverse or unexposed surfaceduring the service life of the product. Performance Requirements are not generally applicable toBacking coats. Where specific Performance Requirements are deemed necessary for the reversesurface coating “double sided” product should be specified, in which case a topcoat of fullnominal thickness will be applied.
EXPECTED PRODUCT SERVICE PERFORMANCE (cont.)
COLORBOND®, ZINCALUME® and CORSTRIP® are registered trade marks of BlueScope Steel Limited.
BlueScope is a trade mark of BlueScope Steel Limted.
Please ensure you have the current data sheet for this product as displayed at www.bluescopesteel.com.au