Page 1: Copyright © 2004 Marconi Corporation plc. All rights reserved Product Overview BXR-48000 Switch Router.

Copyright © 2004 Marconi Corporation plc. All rights reserved

Product Overview

BXR-48000 Switch Router

Page 2: Copyright © 2004 Marconi Corporation plc. All rights reserved Product Overview BXR-48000 Switch Router.

2 Copyright © 2004 Marconi Corporation plc. All rights reserved

Objectives

Explain the hardware configuration of the BXR-48000 Identify the hardware components and their location in the

BXR-48000

Page 3: Copyright © 2004 Marconi Corporation plc. All rights reserved Product Overview BXR-48000 Switch Router.

3 Copyright © 2004 Marconi Corporation plc. All rights reserved

Introduction to the BXR-48000

Multiservice Switch Router Payload agnostic switching

Able to support an aggregate port capacity equal to its fabric capacity

Configurations range from 40 Gbps to 480 Gbps switching capacity

Page 4: Copyright © 2004 Marconi Corporation plc. All rights reserved Product Overview BXR-48000 Switch Router.

4 Copyright © 2004 Marconi Corporation plc. All rights reserved

Upper Fan TrayP

ort

car

d 7

ap

ort

car

d 7

bp

ort

car

d 7

cp

ort

car

d 7

dB

lan

kF

7p

ort

car

d 8

ap

ort

car

d 8

bP

ort

car

d 8

cP

ort

car

d 8

dF

8F

9P

ort

car

d 9

aP

ort

car

d 9

bP

ort

car

d 9

cP

ort

car

d 9

dB

lan

k

Po

rt c

ard

10a

Po

rt c

ard

10b

Po

rt c

ard

10c

Po

rt c

ard

10d

Bla

nk

F10

Po

rt c

ard

11a

Po

rt c

ard

11b

Po

rt c

ard

11c

Po

rt c

ard

11d

F11

F12

Po

rt c

ard

12a

Po

rt c

ard

12b

Po

rt c

ard

12c

Po

rt c

ard

12d

Bla

nk

Lower Fan Tray

Air Inlet Air InletAir Inlet

Filter

PCM

A0

PCM

B0

PCM

A1

PCM

B1

BXR-48000 Hardware Configuration

Upper Fan Tray

Po

rt c

ard

1a

po

rt c

ard

1b

po

rt c

ard

1c

po

rt c

ard

1d

Pro

tect

ion

Fab

ric

Fab

ric

1p

ort

car

d 2

ap

ort

car

d 2

bP

ort

car

d 2

cP

ort

car

d 2

dF

abri

c 2

Fab

ric

3P

ort

car

d 3

aP

ort

car

d 3

bP

ort

car

d 3

cP

ort

car

d 3

dS

CP

X

Po

rt c

ard

4a

Po

rt c

ard

4b

Po

rt c

ard

4c

Po

rt c

ard

4d

Fab

ric

4P

ort

car

d 5

aP

ort

car

d 5

bP

ort

car

d 5

cP

ort

car

d 5

dF

abri

c 5

Fab

ric

6P

ort

car

d 6

aP

ort

car

d 6

bP

ort

car

d 6

cP

ort

car

d 6

dS

CP

Y

TC

M0

T

CM

1

AIM

Lower Fan Tray

Air Inlet Air InletAir Inlet

Filter

PCM

A0

PCM

B0

PCM

A1

PCM

B1

Chassis A

Chassis B

Page 5: Copyright © 2004 Marconi Corporation plc. All rights reserved Product Overview BXR-48000 Switch Router.

5 Copyright © 2004 Marconi Corporation plc. All rights reserved

Port Layout – Fabric 6 Example

Fab

ric

6

SC

P Y

A B C DSlots

1

2

3

4

1

8

16

Port Numbers

Ports for Fabric 6 are identified as 6A1, 6B16, etc.

6B16

Page 6: Copyright © 2004 Marconi Corporation plc. All rights reserved Product Overview BXR-48000 Switch Router.

6 Copyright © 2004 Marconi Corporation plc. All rights reserved

BXR-48000 Chassis

Power Switching, Interfaces and Control Cooling Expansion from single chassis to dual chassis can be a hitless field upgrade (although we recommend an initial dual-chassis installation if possible)

Upper Fan Tray

Card Cages

Lower Fan Tray

Power Conditioning

Modules

Page 7: Copyright © 2004 Marconi Corporation plc. All rights reserved Product Overview BXR-48000 Switch Router.

7 Copyright © 2004 Marconi Corporation plc. All rights reserved

BXR-48000 SCP

Y

X

+

Serial Port

SELECT Button

System LEDsSystem LEDs

NEXT Button

Ethernet Port

NMI Button

Display

Reset Button

Page 8: Copyright © 2004 Marconi Corporation plc. All rights reserved Product Overview BXR-48000 Switch Router.

8 Copyright © 2004 Marconi Corporation plc. All rights reserved

BXR-48000 Dual SCP Configuration

Optional dual SCPs provide protection The primary active SCP emits a "heartbeat" at regular intervals

Primary/Secondary vs. Active/Standby SCPs Primary – is set as the default SCP to control the system after it boots Secondary – is set as the backup SCP should the primary fail Active – is the SCP that is currently controlling the system Standby – is the backup SCP

Page 9: Copyright © 2004 Marconi Corporation plc. All rights reserved Product Overview BXR-48000 Switch Router.

9 Copyright © 2004 Marconi Corporation plc. All rights reserved

BXR-48000 Fabric Modules

Variable-length packet fabric Support up to 12(+1), 40 Gbps

fabrics per chassis One fabric for every four port

cards Contiguous population Protocol agnostic fabrics

Data is distributed evenly across all fabrics

N+1 fabric protection Scales from 240 Gbps to a

480 Gbps system with fabric redundancy

Fail over protection is provided by a "hitless" reconstruction process

LEDs

Ejection/InsertionLevers

Lock

+

Page 10: Copyright © 2004 Marconi Corporation plc. All rights reserved Product Overview BXR-48000 Switch Router.

10 Copyright © 2004 Marconi Corporation plc. All rights reserved

BXR-48000 Port Cards

Input/Output Modules Each port card supports

up to 10 Gbps of full-duplex capacity

Three types: ATM IP-Aware (IPA) ATM Packet over SONET (POS)

+

OC-3c

OC-12c

LEDs

OC-48c

Page 11: Copyright © 2004 Marconi Corporation plc. All rights reserved Product Overview BXR-48000 Switch Router.

11 Copyright © 2004 Marconi Corporation plc. All rights reserved

ATM Port Cards

Cell-based interfaces capable of normal ATM functions PVC, SVC, SPVC Traffic management, per-VC queuing, scheduling ILMI, PNNI routing

ATM port card hardware 16 port OC-3c/STM-1 in multimode and single mode 16 port OC-12c/STM-4* in multimode and single mode 4 port OC-48c/STM-16 in single mode 1 port OC-192c/STM-64 in single mode

* Each port configurable as OC-12c/STM-4 or OC-3c/STM-1

Ejection/InsertionLevers

(with locks)

Page 12: Copyright © 2004 Marconi Corporation plc. All rights reserved Product Overview BXR-48000 Switch Router.

12 Copyright © 2004 Marconi Corporation plc. All rights reserved

IP-Aware (IPA) ATM Port Cards

An IP-aware ATM interface has ATM capabilities plus capabilities in an IP/MPLS network: Hop-by-hop routing when there is no LSP for the destination Can originate or terminate an LSP, encapsulating/decapsulating

packets using RFC 1483/2684 (bridged/routed PVCs) Support for ATM and MPLS control planes on the same port Pseudo Wire Emulation Edge-to-Edge (PWE3) Provider Edge (PE) capability

A topology change can make a transit LSR become an LER, the IPA card performs both roles. Ingress and egress to the MPLS network require IP look-ups A network failure could cause a transit LSR to unexpectedly become

an LER that cannot perform IP lookups

Page 13: Copyright © 2004 Marconi Corporation plc. All rights reserved Product Overview BXR-48000 Switch Router.

13 Copyright © 2004 Marconi Corporation plc. All rights reserved

IPA ATM Port Card Hardware

Port card types, listed by interface: 8 port OC-3c/STM-1 in multimode and single mode 8 port OC-12c/STM-4* in multimode and single mode 2 port OC-48c/STM-16 in single mode

* Each port configurable as OC-12c/STM-4 or OC-3c/STM-1

Page 14: Copyright © 2004 Marconi Corporation plc. All rights reserved Product Overview BXR-48000 Switch Router.

14 Copyright © 2004 Marconi Corporation plc. All rights reserved

Packet over SONET (POS) Port Cards

SONET-based IP interfaces allow direct connection of IP devices

OC-12c and OC-48c POS port cards can be trunks for aggregated IP traffic

Hop-by-hop routing supported Can originate or terminate an LSP

Provider Edge (PE) functionality Multiservice capability over MPLS with PWE3 toward the network

core

Page 15: Copyright © 2004 Marconi Corporation plc. All rights reserved Product Overview BXR-48000 Switch Router.

15 Copyright © 2004 Marconi Corporation plc. All rights reserved

POS Port Card Hardware

Port card types, listed by interface: 12 port OC-3c/STM-1 in multimode and single mode 12 port OC-12c/STM-4* in multimode and single mode 4 port OC-48c/STM-16 in single mode

* Each port configurable as OC-12c/STM-4 or OC-3c/STM-1

Page 16: Copyright © 2004 Marconi Corporation plc. All rights reserved Product Overview BXR-48000 Switch Router.

16 Copyright © 2004 Marconi Corporation plc. All rights reserved

Port Card Scheduling and Queuing

POS and IPA port cards have 16 hardware queues Room to concurrently support ATM service categories,

Diffserv, IntServ and best-effort IP Configurable strict and weighted round robin queues Provides support for unique service offerings

Page 17: Copyright © 2004 Marconi Corporation plc. All rights reserved Product Overview BXR-48000 Switch Router.

17 Copyright © 2004 Marconi Corporation plc. All rights reserved

BXR-48000 Card Carrier/TCM

The card carrier supports: TCM and AIM The TCM(s) are optionally

redundant The TCM provides system

synchronization and manages the timing sources: Primary and secondary line

timing sources Redundant BITS sources Internal Stratum 3E clock

TCM(s) are located on chassis A only

+

TCMTCM

Card CarrierCard Carrier

Page 18: Copyright © 2004 Marconi Corporation plc. All rights reserved Product Overview BXR-48000 Switch Router.

18 Copyright © 2004 Marconi Corporation plc. All rights reserved

BXR-48000 Card Carrier/AIM

Supports five alarm relays Has six LEDs which are:

LED1 - OK (green) LED2 - Critical Alarm (blinking red) LED3 - Major Alarm (red) LED4 - Minor Alarm (amber) LED5 - Unused LED6 - Unused

Located on chassis A only

+

AIMAIM

Card CarrierCard Carrier

Page 19: Copyright © 2004 Marconi Corporation plc. All rights reserved Product Overview BXR-48000 Switch Router.

19 Copyright © 2004 Marconi Corporation plc. All rights reserved

BXR-48000 TIM

The physical connection point for external timing sources on the BXR-48000

Accessible by removing a small cover on the back of chassis A

TIM

Page 20: Copyright © 2004 Marconi Corporation plc. All rights reserved Product Overview BXR-48000 Switch Router.

20 Copyright © 2004 Marconi Corporation plc. All rights reserved

BXR-48000 PCMs

Requires –48v DC power 2(+2) redundancy per

chassis PCMs provide:

EMI filtering Short-term energy storage Reverse feed polarity

protection Reverse discharge

protection Surge suppression Under voltage trip

+

PCM

PCM

A0

PCM

B0

PCM

A1

PCM

B1

Page 21: Copyright © 2004 Marconi Corporation plc. All rights reserved Product Overview BXR-48000 Switch Router.

21 Copyright © 2004 Marconi Corporation plc. All rights reserved

BXR-48000 System Cooling

Two removable fan trays with four fans in each tray

If a single fan fails, the remaining seven fans increase speed to compensate for the loss

Filter and protective screen keeps debris from the chassis

Filter

Protective Screen

Air inlet

Air Exhaust

+

Fan Trays

Page 22: Copyright © 2004 Marconi Corporation plc. All rights reserved Product Overview BXR-48000 Switch Router.

22 Copyright © 2004 Marconi Corporation plc. All rights reserved

BXR-48000 MCP

Provides alarm and control interface between the mothercard and the active SCP

Consists of a high performance processor and memoryF

ab

ric

Po

rt c

ard

Po

rt c

ard

Po

rt c

ard

Po

rt c

ard

Fa

bri

c

Po

rt c

ard

Po

rt c

ard

Po

rt c

ard

Po

rt c

ard

SC

P Y

Fa

bri

c

Po

rt c

ard

Po

rt c

ard

Po

rt c

ard

Po

rt c

ard

Fa

bri

c

Po

rt c

ard

Po

rt c

ard

Po

rt c

ard

Po

rt c

ard

SC

P X

TC

M 0

TC

M 1

MCP MCP MCP MCP MCP MCP MCP MCP MCP MCP MCP

MCP

MCP MCP MCP MCP MCP MCP MCP MCP MCP MCP

Page 23: Copyright © 2004 Marconi Corporation plc. All rights reserved Product Overview BXR-48000 Switch Router.

23 Copyright © 2004 Marconi Corporation plc. All rights reserved

BXR-48000 Cable Management System

Two cable management systems per chassis located: Above the upper card cage Below the lower card cage

Organize and protect fiber cables in the chassis

Protective Doors

Cable Management

Cable Management

Page 24: Copyright © 2004 Marconi Corporation plc. All rights reserved Product Overview BXR-48000 Switch Router.

24 Copyright © 2004 Marconi Corporation plc. All rights reserved

BXR-48000 Management and Configuration

The BXR-48000 supports IP Management: ATM over port card interfaces Over the SCP’s Ethernet port

Can configure remotely using: Command Line Interface (CLI) Element Manager

The SNMP BXR-48000 can be used with Service On Data (SOD) Release 2.0 – SOn-D v2.4

Page 25: Copyright © 2004 Marconi Corporation plc. All rights reserved Product Overview BXR-48000 Switch Router.

25 Copyright © 2004 Marconi Corporation plc. All rights reserved

Summary

Explained the hardware configuration of the BXR-48000 Identified the hardware components and their location in the

BXR-48000