Version 2.0 www.soapp.com 1.312.845.2222 1.312.845.2225 [email protected]Equipment Design Detailed Plant Conceptual Design SOAPP–CT.25 sizes all major plant equipment, based on your Project Input, the process configuration derived from this input, and the results of the heat and material balances, using algorithms derived from design practice and manufacturer’s data. SOAPP–CT.25 summarizes the results of this equipment sizing in an Equipment List containing over 250 equipment design parameters, depending on plant design, including: • 17 general project data • 10 structural design data • 10 combustion turbine system data • 30 HRSG equipment data • 35 pump data • 15 balance of plant equipment data • 30 tank data • 110 piping data • 17 electrical equipment data The Equipment List is supplemented by a Plant Performance Summary, a multimedia Emissions Summary at full load operation, and a Motor List / Auxiliary Power Summary. All of these equip- ment design reports produced by SOAPP–CT.25 are generated dynamically, reflecting every relevant change you make to your Project Input.
13
Embed
Copy of Sample Output Topic Insert ഀ倀愀最攀猀 ⴀ 匀伀䄀倀倀ⴀ …soapp.epri.com/output/soapp-ct25/equipment/Equipment_Summary.pdfTank Capacity 277,225.00 gal Tank Diameter
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Detailed Plant Conceptual Design SOAPP–CT.25 sizes all major plant equipment, based on your Project Input, the process configuration derived from this input, and the results of the heat and material balances, using algorithms derived from design practice and manufacturer’s data. SOAPP–CT.25 summarizes the results of this equipment sizing in an Equipment List containing over 250 equipment design parameters, depending on plant design, including:
• 17 general project data • 10 structural design data • 10 combustion turbine system data • 30 HRSG equipment data • 35 pump data • 15 balance of plant equipment data • 30 tank data • 110 piping data • 17 electrical equipment data
The Equipment List is supplemented by a Plant Performance Summary, a multimedia Emissions Summary at full load operation, and a Motor List / Auxiliary Power Summary. All of these equip-ment design reports produced by SOAPP–CT.25 are generated dynamically, reflecting every relevant change you make to your Project Input.
Variable Value UnitsInside Diameter at Top of Main Stack(s) 9.78 ftMinimum Thickness at Top of Main Stack(s) .25 inMain Stack Top Height Above Grade 80.00 ftMaterial of Construction for Main Stack(s) SteelCOMBUSTION TURBINE DATATurbine/Generator DataNumber of CTs in Plant Design 1 CT NOx Control Technology, Natural Gas Firing Water InjectionCT NOx Emission Limit @ 15% O2 - Natural Gas 25.00 ppmvd @ 15% O2CT Gross Output, per CT 28,939.02 kWCT Gross Heat Rate (LHV) 9,268.00 Btu/kWhCT Exhaust Gas Mass Flow Rate 665,765.75 lb/hCT Exhaust Gas Temperature 909.20 FCT Generator Type Air CooledInlet Air Filtration DataCombustion Turbine Inlet Filter Type Static FilterCombustion Turbine Inlet Filter Height 12.25 ftCombustion Turbine Inlet Filter Length 12.06 ftCombustion Turbine Inlet Filter Width 22.80 ftNumber of Barrier Filters 70 Hours Before Change Out of Barrier Filters 7,500.00 Number of Prefilters 70 Hours Before Change Out of Prefilters 2,500.00 HEAT RECOVERY STEAM GENERATOR DATAHRSG DesignNumber of Heat Recovery Steam Generators (HRSG's) 1 Number of Pressure Levels 2 High Pressure Drum Pinch Point Temp 15.00 FHigh Pressure Steam Drum Approach Temp 20.00 FLow Pressure Drum Pinch Point Temp 15.00 FLow Pressure Steam Drum Approach Temp .00 FHRSG DimensionsHRSG Height 64.00 ftHRSG Length 96.00 ftHRSG Width 29.00 ftDeaeratorDeaerator Type Standalone DeaeratorDeaerator Cond Inlet Perf. Pt. Mass Flow 122,762.04 lb/hDeaerator Cond Inlet Perf. Pt. Pressure 110.00 psiaDeaerator Cond Inlet Perf. Pt. Temperature 60.08 FDeaerator Vent Losses Perf. Pt. Mass Flow 245.52 lb/hDuct BurnersDuct Burner Included YesDuct Burner Primary Fuel Natural GasNumber of Duct Burner Elements 2 Duct Burner Width 29.00 ftDuct Burner Height 34.47 ftDuct Burner Cooling Air Fan Standard Motor Size .33 hp
Variable Value UnitsDuct Burner Cooling Air Fan Auxiliary Power .50 kWPUMP DATAHigh Pressure Feed PumpsSparing 1@100%Type Horizontal Split-Cage MulCapacity 351.87 gpmNet Developed Head 1,870.78 ft H2OStandard Motor Size 250.00 hpLow Pressure Feed PumpsSparing 1@100%Type Horizontal Split-CageCapacity 19.83 gpmNet Developed Head 106.90 ft H2OStandard Motor Size 1.00 hpCondensate PumpsSparing 1@100%Type Horizontal Split-CageCapacity 349.37 gpmNet Developed Head 70.07 ft H2OStandard Motor Size 10.00 hpMiscellaneous PumpsPretreatment Backwash Transfer PumpsSparing 2@100%Type VerticalCapacity 9.98 gpmTotal Developed Head 100.00 ft H2OStandard Motor Size .50 hpWaste Water PumpsSparing 2@100%Type Horizontal Split CageCapacity 99.45 gpmTotal Developed Head 200.00 ft H2OStandard Motor Size 10.00 hpWater Treatment System Makeup PumpsSparing 2@100%Type Horizontal Split CageCapacity 342.65 gpmTotal Developed Head 200.00 ft H2OStandard Motor Size 30.00 hpWater Treatment System Raw Water PumpsSparing 1@100%Type VerticalCapacity 967.65 gpmTotal Developed Head 300.00 ft H2OStandard Motor Size 100.00 hpBOP EQUIPMENT DATAInstrument & Station Air CompressorsType Screw
Variable Value UnitsNon-segregated Phase Bus Duct - Length 100.00 ftNon-segregated Phase Bus Duct - CT UAT to non-seg bus ducts 300.00 ANon-segregated Phase Bus Duct - Length 150.00 ftNon-segregated Bus Duct 1,800.00 ANon-segregated Bus Duct, Length 84.00 ftCircuit Breaker - CT, Quantity 1 Circuit Breaker - CT Generator 1,400.00 AMedium Voltage Breaker - CT UAT, Quantity 1 Medium Voltage Breaker - CT UAT 300.00 AMedium Voltage Breaker - CT Starter, Quantity 1 Medium Voltage Breaker - CT Starter 120.00 AMedium Voltage Breaker - BFW Pump, Quantity 0 Medium Voltage Breaker - BFW Pump .00 AMedium Voltage Breaker - Unit Substation, Quantity 2 Medium Voltage Breaker - Unit Substation 200.00 ALow Voltage Breaker - Unit Substation, Quantity 2 Low Voltage Breaker - Unit Substation 1,800.00 ALow Voltage Breaker - Bus Coupler, Quantity 1 Low Voltage Breaker - Bus Coupler 1,800.00 ALow Voltage Breaker - Power Centers, Quantity 2 Low Voltage Breaker - Power Centers 500.00 ALow Voltage Breaker - Motor Control Center, Quantity 2 Low Voltage Breaker - Motor Control Center 100.00 ASwitchyard Voltage 115.00 kV