Wire range taking capability Designed to terminate #14 – #10 AWG stranded and #12 – #10 AWG solid copper code conductors Offers a single lug to terminate a range of conductor sizes, resulting in lower inventory costs Inspection window Permits viewing of cable placement inside the barrel Allows for visual verification of proper cable insertion before and after crimping Electro tin plated Provides corrosion resistance Provides for long term, durable terminations Copper Compression Lugs For Terminating #14 – #10 AWG Copper Conductors Everywhere y Everywhere y ou need us! ou need us! PANDUIT ® offers copper compression lugs for terminating #14 – #10 AWG copper conductors. The lugs are available in standard and long barrel lengths, offered with one or two mounting holes, in straight, 45° and 90° bent configurations. These lugs can be crimped with a wide variety of PANDUIT ® crimp tools for UL Listed and CSA Certified terminations. Building on the existing line of lugs for #8 AWG – 1000 kcmil, PANDUIT ® copper compression lugs meet the requirements of virtually any application. Seamless copper tubing features, advantages and benefits Eliminates split seams when crimped, providing a tongue with double material thickness Provides terminations with premium electrical performance and mechanical strength UL Listed and CSA Certified electrical terminations Meets the standards of independent safety testing organization: Underwriters Laboratories, Inc. and Canadian Standards Association Provides reliable, high quality electrical terminations ELECTRICAL GROUP
4
Embed
Copper Compression Lugs For Terminating...Two Hole Lug, Standard Barrel Copper Lugs, For Copper Code Conductors Only PANDUIT ® Part Number Copper Conductor Size A W G S Std. Pkg.
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Wire rangetaking capability
Designed to terminate #14 – #10 AWGstranded and #12 – #10 AWG solidcopper code conductors
Offers a single lug to terminate a range of conductorsizes, resulting in lower inventory costs
Inspection window Permits viewing of cable placementinside the barrel
Allows for visual verification of proper cableinsertion before and after crimping
Electro tin plated Provides corrosion resistance Provides for long term, durable terminations
Copper Compression Lugs For Terminating#14 – #10 AWG Copper Conductors
Everywhere yEverywhere you need us!ou need us!
PANDUIT ® offers copper compression lugs for
terminating #14 – #10 AWG copper conductors.
The lugs are available in standard and long barrel
lengths, offered with one or two mounting holes, in
straight, 45° and 90° bent configurations. These
lugs can be crimped with a wide variety of
PANDUIT ® crimp tools for UL Listed and CSA
Certified terminations. Building on the existing line
of lugs for #8 AWG – 1000 kcmil, PANDUIT ® copper
compression lugs meet the requirements of virtually
any application.
Seamless copper tubing
features, advantages and benefits
Eliminates split seams when crimped,providing a tongue with doublematerial thickness
Provides terminations with premium electricalperformance and mechanical strength
UL Listed and CSA Certifiedelectrical terminations
Meets the standards of independentsafety testing organization:Underwriters Laboratories, Inc. andCanadian Standards Association
Provides reliable, high quality electrical terminations
Type LCB-WOne Hole Lug, Long BarrelCopper Lugs, For Copper Code Conductors Only
PPAANNDDUUIITT ®
PartNumber
CopperConductor
Size A W G
Std.Pkg.Qty.
50
50
50
1/4 1.30 .42 .25LCB10-14W-L
1/4 .94 .42 .25LCB10-14WH-L
1/4 1.15 .42 .25LCB10-14WF-L
Dimensions (In.)
✓ Choose Type LCA one-hole or Type LCD two-hole lugs with standard barrellength (#14 – #10 AWG lugs), to meet minimum space requirements.
✓ Choose Type LCB-W one-hole or Type LCC-W two-hole lugs with long barrellength (#14 – #10 AWG lugs), which allows multiple crimps for premium wirepull-out strength.
Order the number of pieces required in multiples of standard package quantity.* Two crimps required.
STRAIGHTTONGUE (Fig. 1)
45 ° ANGLE TONGUE(Fig. 2)
90° ANGLE TONGUE(Fig. 3)
INSPECTIONWINDOW
A
W
G
INSPECTIONWINDOW
A
45˚INSPECTIONWINDOW
90˚
A
#14 – #10 AWGStranded
#12 – #10 AWGSolid
CT-1570,CT-1701,CT-100,CT-200
PPAANNDDUUIITT ®
PartNumber
BoltHole
Size (In.)
CopperConductor
SizeFig.
# A W G
PPAANNDDUUIITT ®
CrimpTools*
#10
#10
#10
3
2
1
1
2
3
1
1
.85
1.06
.96
.38
.38
.38
.23
.23
.23
Std.Pkg.Qty.
LCA10-10F-L
LCA10-10-L
LCA10-10H-L
1/4 1.15 .42 .25LCA10-14-L
1/4 1.05 .42 .25LCA10-14H-L
1/4 .94 .42 .25LCA10-14F-L
5/16 1.27 .54 .32LCA10-56-L
3/8 1.37 .56 .36LCA10-38-L
Dimensions (In.)
#14 – #10 AWGStranded
#12 – #10 AWGSolid
Type LCAOne Hole Lug, Standard BarrelCopper Lugs, For Copper Code Conductors Only
Order the number of pieces required in multiples of standard package quantity.* One crimp required.
■ Crimps insulated and multi-use, non-insulated connectors#22 – #10 AWG
■ Cuts wire #10 AWG■ 90-day warranty
CT-1701 CONTOUR CRIMP ™ Tool
CT-1570 CONTOUR CRIMP ™ Tool
CT-100 Plier Type Tool
CT-200 Plier Type Tool
PANDUIT ® offers a broad line of power connectors andtools for virtually any application in sizes from#22 AWG – 1000 kcmil. The full offering includes copper,aluminum, compression and mechanical connectors foruse in power and grounding applications.
SSAA--PPCCCCBB00113/2004
FFoorr mmoorree iinnffoorrmmaattiioonn oorr ttoo rreeqquueesstt aa ccaattaalloogg880000--777777--33330000