Top Banner
Section 9
10

Control - Amazon S3€¦ · Tank Level Indicator ® General Pump Control & Level Indication Section 9 FPC-12705 & FPC-12706 & FPC-12707 Schematic This simple, yet highly effective

Apr 30, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Control - Amazon S3€¦ · Tank Level Indicator ® General Pump Control & Level Indication Section 9 FPC-12705 & FPC-12706 & FPC-12707 Schematic This simple, yet highly effective

Control

Section 9

Page 2: Control - Amazon S3€¦ · Tank Level Indicator ® General Pump Control & Level Indication Section 9 FPC-12705 & FPC-12706 & FPC-12707 Schematic This simple, yet highly effective

Australia

®

Grey Water Pump ControllerGeneral Pump Control & Level Indication

The MATelec Grey Water Pump Controller is designed for the management of Grey Water. Grey Water is the water discharged from baths, showers and laundries. The unique design enables the controller to monitor the levels of Grey Water in a tank and activates the pump to start and stop supply of Grey Water to selected outlets, such as the garden. If no activity (pump not worked) for 24hrs, the system will automatically activate the pump to pump out any residual Grey Water present in the tank. Controller compatibable with probes and floats.

Schematic

GREY WATER PUMPCONTROLLER

POWER PUMP RUN

DANGER HIGH VOLTAGE DO NOT REMOVE COVERAUTHORISED PERSONS ONLY

FPC-12500 “Econo”Dimensions - 85mm (h) x 55mm (d) x 125mm (w)

FPC-12504 “Quick Plug”Dimensions - 119mm (h) x 73mm (d) x 160mm (w)

Section 9

FPC-12500, FPC-12501 & FPC-12504

A P P L I C A T I O N S

G R E Y W A T E RG A R D E N

L A U N D R Y S H O W E R & B A T H W A T E R

G R E Y W A T E R

GREY WATERPUMP CONTROLLER

POWERON

PUMPRUN

GREY WATERPUMP CONTROLLER

POWERON

PUMPRUN

GREY WATERPUMP CONTROLLER

POWERON

PUMPRUN

FPC-12501 “Standard”Dimensions - 119mm (h) x 73mm (d) x 160mm (w)

Page 3: Control - Amazon S3€¦ · Tank Level Indicator ® General Pump Control & Level Indication Section 9 FPC-12705 & FPC-12706 & FPC-12707 Schematic This simple, yet highly effective

Australia

®

Rain/Stormwater - Tank FillGeneral Pump Control & Level Indication

FPC-11005 & FPC-11006

Section 9

STORM WATER RAIN/STORM WATER OVERFLOW

RAIN WATERTANK FILL

TANK FULL

Spare glandedpenetration providedfor Float Switch cable

STORAGE TANKTRANSFER PIPE

COLLECTION PIT

Schematic

This simple, yet effective controller provides the means of controlling an automatic pump, used to transfer stormwater from a collection pit, to a storage tank. The system provides for ‘Low Voltage’ cabling between the float switch, situated in the storage tank, and the controller. When the storage tank is full, the controller inhibits the pump and the ‘Tank Full’ light is illuminated.

Controller Enclosure c/w power lead and moulded plugMounting brackets9006 NRB 10m Cable Float SwitchQuick Plug connection for pump

FPC-11005 - Standard VersionKit Includes

• Automatic ‘Tank Full’ pump inhibitor • ‘Tank Full’ indicator light • Low voltage Float Switch circuitry • Rated for pumps up to 8Amps• Weatherproof polycarbonate enclosure

Features

Controller Enclosure c/w power lead and moulded plugMounting brackets9006 NRB 10m ‘Quick Plug” Float SwitchQuick Plug connection for pumpQuick Plug connection for float switch

FPC-11006 - ‘Quick Plug’ VersionKit Includes

TRANSFER PIPE

STORM WATER RAIN/STORM WATER OVERFLOW

COLLECTION PIT

STORAGE TANK

‘Quick Plug’ Float Switch connection provided

RAIN WATERTANK FILL

TANK FULL

Page 4: Control - Amazon S3€¦ · Tank Level Indicator ® General Pump Control & Level Indication Section 9 FPC-12705 & FPC-12706 & FPC-12707 Schematic This simple, yet highly effective

Australia

®

Pump Shut Off ControllerGeneral Pump Control & Level Indication

Schematic

Section 9

T O H O U S E

M A I N S W A T E R

B A L L V A L V E

2 4 0 V a c

2 4 V a c

P U M P2 4 0 V a c

F O O T V A L V E

PUMP SHUT OFFCONTROLLER

POWER ON LOW LEVEL

Low Level - Pump ‘Shut Off’ Controller FPC-11010

This simple, yet effective controller provides the means of controlling an automatic pump, used to pump water from a tank into the home. The system provides for ‘Low Voltage’ cabling between the float switch, situated in the storage tank, and the controller. When the storage tank is empty, the controller inhibits the pump and the ‘Low Level’ light is illuminated. Power to the pump is restored once water level in the tank has risen to the reset level.

Controller Enclosure c/w power lead and moulded plugMounting brackets9006 NRB 10m Cable Float Switch

Kit Includes• ‘Power on’ indication • ‘Low level’ indication • 10Amp switch rating • ‘Quick Plug’ pump and float switch DIY connection• Low voltage float switch circuitry

Features

Page 5: Control - Amazon S3€¦ · Tank Level Indicator ® General Pump Control & Level Indication Section 9 FPC-12705 & FPC-12706 & FPC-12707 Schematic This simple, yet highly effective

Australia

®

Liquid Level ControllerGeneral Pump Control & Level Indication

Schematic

The MATelec Liquid Level Controller is ideal for maintain-ing water at predetermined levels in a tank. The controller receives inputs from a float switch, which is located in the water tank. By utilizing either the ‘normally open’ or the ‘normally closed’ output contacts, the system can be used for either filling or emptying a tank. The 24Vac output can be directly connected to a solenoid valve for mains ‘top up’ systems or, alternately, could be used to energise the contacts of a relay or contactor coils for pump or motor control.

Features • Simple retro-fit• Ideal for swimming pools, water tanks and reservoirs• Delay in activation obviates wave induced switching• ‘Power On’ and ‘relay switched’ indication• Switching differential - Min 25mm - Max 10m• Distance of probe from electronics up to 20m

LIQUID LEVELCONTROLLER

POWERON

RELAYSWITCHED

FPC-12700Dimensions - 85mm x 55mm x 125mm

Section 9

FPC-12700

MAINS WATER

2 4 V a c S o l e n o i d V a l v eF l o a t S w i t c h

LIQUID LEVELCONTROLLER

POWERON

RELAYSWITCHED

FLOATSWITCH VALVE

24Vac

Page 6: Control - Amazon S3€¦ · Tank Level Indicator ® General Pump Control & Level Indication Section 9 FPC-12705 & FPC-12706 & FPC-12707 Schematic This simple, yet highly effective

Australia

®

Tank Level IndicatorGeneral Pump Control & Level Indication

Section 9

FPC-12705 & FPC-12706 & FPC-12707

Schematic

This simple, yet highly effective Tank Level Indicator provides an extemely accurate and informative indication of water level within a tank. The controller is coupled to a Hydrostatic Pressure Transducer, which provides a 4-20mA signal to the Process Meter. The Process Meter displays the level in very clear LED numerals.

Control Panel housing Process MeterFlex & Plug for connection to Mains powerStainless Steel Hydrostatic Pressure Transducer c/w 10m cable

FPC-12705 Standard VersionKit Includes

• Hydrostatic Pressure Transducer rating: 0-10m• Process Meter has 2 relay outputs • Display can be configured to read: m/mm (depth),

percentage (full) or litres (capacity)

Features

TANK LEVEL INDICATOR

TANK LEVEL INDICATOR

TRANSMITTER

Control Panel housing Process MeterFlex & Plug for connection to Mains powerStainless Steel Hydrostatic Pressure Transducer c/w 10m cableTransmitterReceiver

FPC-12706 Wireless VersionKit Includes

TANK LEVEL INDICATORProcess Meter

Optional: Sewage/Waste water Transducer available

Page 7: Control - Amazon S3€¦ · Tank Level Indicator ® General Pump Control & Level Indication Section 9 FPC-12705 & FPC-12706 & FPC-12707 Schematic This simple, yet highly effective

Rain/Mains WaterController

DO NOT REMOVE COVER - AUTHORISED PERSONS ONLYDANGER HIGH VOLTAGE

SYSTEMTEST

Press to changeSystem Status

MAINSWATER

TANKWATER

FPC-SERIES

TRANSMITTERRECEIVER

Australia

®

Remote Signal CommunicatorGeneral Pump Control & Level Indication

Section 9

Schematics

Functional Overview

The MATelec Remote Signal Communicator is designed, manufactured and tested to be compatable with all MATelec liquid level control products where a switched input is required. The system, which comprises two models, mains and solar power versions, enables remote switching, necessary when interlink cabling is either not practical or too costly. The units are set to communicate a signal burst every 60 seconds, ensuring reliability and con-

sistancy. The transmitter is supplied complete with an antenna and, where necessary, an optional antenna is available for the receiver.

PLEASE NOTE: If required, the ‘Receiver’ Unit from either models, can be mounted within the enclosure of the controller that it is interfacing with. Pricing and implication would be enquiry specific.

• No interlink cabling is required• No costly and disruptive excavations• Up to 500m range (conditions apply)• Maintenance free• Australian Standards compliant

Features

TRANSMITTER

RECEIVERRain/Mains WaterController

DO NOT REMOVE COVER - AUTHORISED PERSONS ONLYDANGER HIGH VOLTAGE

SYSTEMTEST

Press to changeSystem Status

MAINSWATER

TANKWATER

FPC-SERIES

IP55 Weatherproof EnclosuresTransmitterReceiverRegulator7.2Amp/hr Battery5W Solar Panel

Optional Extra: FPC-13098 Receiver Antenna

NOTE: Pole for Solar Panel not included.

IP55 Weatherproof EnclosuresTransmitterReceiver

Optional Extra: FPC-13098 Receiver Antenna

Kit Includes

Kit Includes

FPC-13095 Mains Powered Communicator

FPC-13096 Solar Powered Communicator

Page 8: Control - Amazon S3€¦ · Tank Level Indicator ® General Pump Control & Level Indication Section 9 FPC-12705 & FPC-12706 & FPC-12707 Schematic This simple, yet highly effective

Australia

®

Dual Water - Master Valve ControllerGeneral Pump Control & Level Indication

Section 9

Schematic

FPC-12765 Functional Overview

Example of application:With Stage 3 water resitrictions in place, a home

owner is only allowed to water lawn and garden with Rain water. However, with Stage 3 resitrictions in place, it is permissible to water garden beds with Mains water. Should restrictions be lifted from Stage 4 to Stage 3, this change is made simple with the MATelec controller by moving the selector switch from Stage 4 to Stage 3, the rest happens automatically.

• Rain water Master Valve switched indication• Mains water Master Valve switched indication• Simple setup of station allocation• User friendly selection of water supply

Features

MASTER VALVEMAINS WATER

MASTER VALVERAIN WATER

1

3

4

STAGE

RESTRICTION LEVEL

1LAWN

GARDEN

2LAWN

GARDEN

3LAWN

GARDEN

4LAWN

GARDEN

5LAWN

GARDEN

6LAWN

GARDEN

MASTER VALVEMAINS WATER

MASTER VALVERAIN WATER

1

3

4

STAGE

RESTRICTION LEVEL

1LAWN

GARDEN

2LAWN

GARDEN

3LAWN

GARDEN

4LAWN

GARDEN

5LAWN

GARDEN

6LAWN

GARDEN

IRRIGATIONCONTROLLER

RAIN WATER MASTER VALVE

MAINS WATER MASTER VALVE

STATION 3STATION 2STATION 1

GARDEN

LAWN

RAINWATER

MAINSWATER

Controller c/w selector switches and indicator lightsTerminations for inputs from irrigation controllerTerminations for outputs to solenoid valves

Kit Includes

For use in conjunction with almost any irrigation controller, this unique MATelec Dual Water Master - Valve Controller, is ideal for irrigation systems, where there is a dual water source ie; Mains water and Rain water. The controller is designed to automatically select the appropriate water source for a particular watering station ie; lawns or garden beds. The controller enables the operator, at the flick of a switch, to change the water source for particular stations ensuring compliance with changing levels/stages of water restrictions.

Page 9: Control - Amazon S3€¦ · Tank Level Indicator ® General Pump Control & Level Indication Section 9 FPC-12705 & FPC-12706 & FPC-12707 Schematic This simple, yet highly effective

Australia

®

Leak Detection & Mains Water IsolatorGeneral Pump Control & Level Indication

P O W E R S U P P LY

1 . C o n d u c t i v i t y P r o b e w i l l d e t e c t p r e s e n c e o f

w a t e r

2 . I f w a t e r i s d e t e c t e d , S o l e n o i d V a l v e w i l l

i s o l a t e M a i n s W a t e r

3 . M a i n s W a t e r w i l l a l s o b e i s o l a t e d i n

t h e e v e n t o f p o w e r f a i l u r e

1 0 0 m m

P R O B ES A D D L E DI N P L A C E

WAT E R M A I N S

S O L E N O I D VA LV E

MAINS WATER ON

MAINS WATER OFF

LEAK DETECTED

Section 9

FPC-12742 Functional Overview

This controller has been developed for areas where there is a risk of a major leak or spill that could occur at any time, which requires the automatic shut-off of the Mains water supply.The system is made up of a controller complete with status indication, a moisture/water detection probe and a specifically engineered DC Pulse Latching Solenoid Valve.

• Continuous Monitoring• Clear Status Indication• Power Fail-Valve Closed feature• Manual Overide• BMS available as V/F Contacts

Features

Available Valve Sizes

25mm40mm50mm

MAINS WATER ON

MAINS WATER OFF

LEAK DETECTED

Flow l/min “MAX”

Powder Coated Control PanelConductivity probe c/w 10m Cable316 Stainless Steel SaddleValve c/w DC Pulse Latching Solenoid

Kit Includes

120300450

Size

Page 10: Control - Amazon S3€¦ · Tank Level Indicator ® General Pump Control & Level Indication Section 9 FPC-12705 & FPC-12706 & FPC-12707 Schematic This simple, yet highly effective

Australia

®

Intrinsically Safe Pump Start SwitchGeneral Pump Control & Level Indication

TRANSFORMER240Vac / 24Vdc

PUMP

FLOAT 1 FLOAT 2

INTRINSICALLY SAFECONNECTIONS

RELAY

Eart

h

Activ

e

Neu

tral

INSU

LATI

ON

BA

RRIE

R

INTRINSICALLY SAFEBARRIER RELAY

Under Lid Inside Componentry

INTRINSICALLY SAFEPUMP SWITCH

PowerSupplyEntry

PumpPowerEntry

FloatSwitchEntry

F U E L S E R V I C E S TAT I O N

Located in “Safe Area”

Intrinsically Safe FloatSwitch connection

EX Pump

INTRINSICALLY SAFEPUMP SWITCH

Schematic

FPC-15805 Functional Overview

It is a common requirement for applications where fuels and hydrocarbons could potentially be present, to have an Intrinsically Safe Installation specified. Whilst many pumps have the appropriate Ex approvals for these applications, accredited level switches, that provide the Start and Stop signal for these pumps are difficult to come by.The MATelec Intrinsically Safe Pump Start Switch Controller provides a simple yet effective solution for these installations.Incorporating an Intrinsically Safe Barrier Relay, the controller is designed to switch a 240Vac Pump utilising a standard float style switch.

• 240Vac 10amp Pump Switching• Poly Carbonate Weatherproof Enclosure• LED Status Indication on Barrier Relay

Features