13-1 Casement & Awning Windows A R C H I T E C T U R A L D E T A I L F I L E REV.02/08 Contents Architectural Casement & Awning Windows Basic Unit Details Casement Aluminum Clad Venting Windows Rectangular .............................................................................. 13-2 Trapezoid .................................................................................. 13-3 Archtop and Unequal Leg Archtop............................................. 13-4 Springline ™ .............................................................................. 13-5 Springline ™ Flanker .................................................................. 13-6 Basic Unit Details Casement Aluminum Clad Fixed Windows Rectangular .............................................................................. 13-7 Trapezoid .................................................................................. 13-8 Archtop and Unequal Leg Archtop ............................................ 13-9 Springline ™ and Springline ™ Flanker ...................................... 13-10 Basic Unit Details French Casement Aluminum Clad Venting Windows Rectangular ............................................................................ 13-11 Archtop .................................................................................. 13-12 Springline ™ ............................................................................ 13-13 Basic Unit Details French Casement Aluminum Clad Fixed Windows Rectangular ............................................................................ 13-14 Archtop .................................................................................. 13-15 Springline ™ ............................................................................ 13-16 Basic Unit Details Awning Aluminum Clad Venting Windows ......... 13-17 Optional Exterior Aluminum Brickmould....................................... 13-18 Clear Opening Details Rectangular ............................................................................ 13-19 Shaped .................................................................................. 13-20 French Casement ................................................................... 13-21 Awning ................................................................................... 13-17 Suggested Product Applications .................................................. 13-22 • .050" thick aluminum exterior cladding with AAMA 2604 finish as standard. AAMA 2605 finish is optional. • Factory-applied 4-9/16" , 5-1/4" , 6-9/16" , 7-1/8" and custom width extension jambs. • Insect screens. • Curved interior casings. • Curved exterior aluminum brickmould. • Pine, oak, maple or prefinished white interiors.
23
Embed
Contents Architectural Casement & Awning Windows...Casement Aluminum Clad Venting Windows — Archtop and Unequal Leg Archtop Details Scale 3" = 1'-0" (1:4) Minimum Rough Opening rough
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
13-1
C a s e m e n t & A w n i n g W i n d o w s
A r C h i t e C t u r A l D e t A i l F i l er e v . 0 2 / 0 8
Contents
Architectural Casement & Awning Windows
Basic unit Details Casement Aluminum Clad venting Windows
ght* * See page 13-16 for Clear Opening information
Unit Dimension Width
1-1/8" (29)
4-9
/16"
(116
) Jam
b W
idth
1-5/16"(33)
1/4" (6) 1/4" (6)
3-3
/8"
(86)
Unit
Dim
ensi
on H
eigh
t
1/4" (6)
Unobstructed Glass Width
1-7/16"(37)
1-1/8"(29)
1-1/8"(29)
1-1/8"(29)
4-9/16" (116) Jamb Width
1-5/16" (33) 3-3/8" (86)
Jamb Jamb
Sill SillSingle Glazed Option
SillDecorative TripleGlazed Option
Head
Optional extension jambs
Insect screen
Optional extension jambs
Insect screen
Vertical Section
Horizontal Section
Minimum Rough Opening
rough opening dimensions shown are the minimum dimensions recommended for proper installation. these dimensions may need to be increased to allow for use of building wraps, flashing, sill or pan
flashing, brackets, fasteners or other items which could decrease these dimensions. Adjusting rough opening dimensions to accommodate these materials is the responsibility of the designer or installer.
13-3
C a s e m e n t & A w n i n g W i n d o w s
A r C h i t e C t u r A l D e t A i l F i l er e v . 0 2 / 0 8
rough opening dimensions shown are the minimum dimensions recommended for proper installation. these dimensions may need to be increased to allow for use of building wraps, flashing, sill or pan
flashing, brackets, fasteners or other items which could decrease these dimensions. Adjusting rough opening dimensions to accommodate these materials is the responsibility of the designer or installer.
13-4
C a s e m e n t & A w n i n g W i n d o w s
A r C h i t e C t u r A l D e t A i l F i l e r e v . 0 2 / 0 8
Minimum Rough Opening Width
3-1/8" (79) 3-1/8" (79)
3-1
/8"
(79)
1/4" (6)
3-1
/8"
(79)
7/8"(22)
Min
imum
Rou
gh O
peni
ng H
eigh
t
Unob
stru
cted
Gla
ss H
eigh
t
Clea
r Ope
ning
Hei
ght*
Unit Dimension Width
1-1/8" (29)
4-9
/16"
(116
) Jam
b W
idth
1-5/16" (33)
1/4" (6) 1/4" (6)
3-3
/8"
(86)
Unit
Dim
ensi
on H
eigh
t
1/4" (6)
Unobstructed Glass Width
1-7/16" (37)
1-1/8" (29)
7/8" (22)
Archtop Unequal Leg Archtop
1-1/8" (29)
4-9/16" (116) Jamb Width
1-5/16" (33) 3-3/8" (86)
Jamb Jamb
Sill Sill Single Glazed Option
Sill Decorative Triple
Glazed Option
Head
Optional extension jambs
Optional interior casing
Insect screen
* See page 13-17 for Clear Opening information
Optional extension jambs
Insect screen
Vertical Section
Horizontal Section
Basic Unit Details
Casement Aluminum Clad Venting Windows — Archtop and Unequal Leg Archtop DetailsScale 3" = 1'-0" (1:4)
Minimum Rough Opening
rough opening dimensions shown are the minimum dimensions recommended for proper installation. these dimensions may need to be increased to allow for use of building wraps, flashing, sill or pan
flashing, brackets, fasteners or other items which could decrease these dimensions. Adjusting rough opening dimensions to accommodate these materials is the responsibility of the designer or installer.
13-5
C a s e m e n t & A w n i n g W i n d o w s
A r C h i t e C t u r A l D e t A i l F i l er e v . 0 2 / 0 8
rough opening dimensions shown are the minimum dimensions recommended for proper installation. these dimensions may need to be increased to allow for use of building wraps, flashing, sill or pan
flashing, brackets, fasteners or other items which could decrease these dimensions. Adjusting rough opening dimensions to accommodate these materials is the responsibility of the designer or installer.
13-6
C a s e m e n t & A w n i n g W i n d o w s
A r C h i t e C t u r A l D e t A i l F i l e r e v . 0 2 / 0 8
rough opening dimensions shown are the minimum dimensions recommended for proper installation. these dimensions may need to be increased to allow for use of building wraps, flashing, sill or pan
flashing, brackets, fasteners or other items which could decrease these dimensions. Adjusting rough opening dimensions to accommodate these materials is the responsibility of the designer or installer.
13-7
C a s e m e n t & A w n i n g W i n d o w s
A r C h i t e C t u r A l D e t A i l F i l er e v . 0 2 / 0 8
rough opening dimensions shown are the minimum dimensions recommended for proper installation. these dimensions may need to be increased to allow for use of building wraps, flashing, sill or pan
flashing, brackets, fasteners or other items which could decrease these dimensions. Adjusting rough opening dimensions to accommodate these materials is the responsibility of the designer or installer.
1/4" (6)
Roug
h Op
enin
g He
ight
3-3/8" (86)
4-9/16" (116) Jamb Width
3-1/
8" (7
9)
Unit
Dim
ensi
on H
eigh
t
Clea
r Gla
ss H
eigh
t3-
1/8"
(79)
1-5/16" (33)
1/4" (6)
Extension Jamb
7/8" (22)
1-1/8" (29)
1-1/8" (29)
1-1/8" (29)
Rough Opening Width
1-1/8" (29)
Unit Dimension Width
4-9/
16"
(116
) Jam
b W
idth
1-5/16" (33)
1/4" (6)
3-3/
8" (8
6)
7/8" (22)
1/4" (6)
3-1/8" (79) Clear Glass Width
Head
Sill
Vertical Section
Horizontal Section
Jamb Jamb
Rectangular
13-8
C a s e m e n t & A w n i n g W i n d o w s
A r C h i t e C t u r A l D e t A i l F i l e r e v . 0 2 / 0 8
rough opening dimensions shown are the minimum dimensions recommended for proper installation. these dimensions may need to be increased to allow for use of building wraps, flashing, sill or pan
flashing, brackets, fasteners or other items which could decrease these dimensions. Adjusting rough opening dimensions to accommodate these materials is the responsibility of the designer or installer.
1/4" (6)
Roug
h Op
enin
g He
ight
3-3/8" (86)
4-9/16" (116) Jamb Width
3-1/
8" (7
9)
Unit
Dim
ensi
on H
eigh
t
Clea
r Gla
ss H
eigh
t3-
1/8"
(79)
1-5/16" (33)
1/4" (6)
Extension Jamb
7/8" (22)
1-1/8" (29)
1-1/8" (29)
1-1/8" (29)
Rough Opening Width
1-1/8" (29)
Unit Dimension Width
4-9/
16"
(116
) Jam
b W
idth
1-5/16" (33)
1/4" (6)
3-3/
8" (8
6)
7/8" (22)
1/4" (6)
3-1/8" (79) Clear Glass Width
Head
Sill
Vertical Section
Horizontal Section
Jamb Jamb
Trapezoid
13-9
C a s e m e n t & A w n i n g W i n d o w s
A r C h i t e C t u r A l D e t A i l F i l er e v . 0 2 / 0 8
Basic Unit Details
Casement Aluminum Clad Fixed Windows — Arch Top DetailsScale 3" = 1'-0" (1:4)
Minimum Rough Opening
rough opening dimensions shown are the minimum dimensions recommended for proper installation. these dimensions may need to be increased to allow for use of building wraps, flashing, sill or pan
flashing, brackets, fasteners or other items which could decrease these dimensions. Adjusting rough opening dimensions to accommodate these materials is the responsibility of the designer or installer.
1/4" (6)
Roug
h Op
enin
g He
ight
3-3/8" (86)
4-9/16" (116) Jamb Width
3-1/
8" (7
9)
Unit
Dim
ensi
on H
eigh
t
Clea
r Gla
ss H
eigh
t3-
1/8"
(79)
1-5/16" (33)
1/4" (6)
Extension Jamb
7/8" (22)
1-1/8" (29)
1-1/8" (29)
1-1/8" (29)
Rough Opening Width
1-1/8" (29)
Unit Dimension Width
4-9/
16"
(116
) Jam
b W
idth
1-5/16" (33)
1/4" (6)
3-3/
8" (8
6)
7/8" (22)
1/4" (6)
3-1/8" (79) Clear Glass Width
Head
Sill
Vertical Section
Archtop
Unequal Leg Archtop
Horizontal Section
Jamb Jamb
13-10
C a s e m e n t & A w n i n g W i n d o w s
A r C h i t e C t u r A l D e t A i l F i l e r e v . 0 2 / 0 8
rough opening dimensions shown are the minimum dimensions recommended for proper installation. these dimensions may need to be increased to allow for use of building wraps, flashing, sill or pan
flashing, brackets, fasteners or other items which could decrease these dimensions. Adjusting rough opening dimensions to accommodate these materials is the responsibility of the designer or installer.
1/4" (6)
Roug
h Op
enin
g He
ight
3-3/8" (86)
4-9/16" (116) Jamb Width
3-1/
8" (7
9)
Unit
Dim
ensi
on H
eigh
t
Clea
r Gla
ss H
eigh
t3-
1/8"
(79)
1-5/16" (33)
1/4" (6)
1-1/8" (29)
1-1/8" (29)
Extension Jamb
7/8" (22)
1-1/8" (29)
Rough Opening Width
1-1/8" (29)
Unit Dimension Width
4-9/
16"
(116
) Jam
b W
idth
1-5/16" (33)
1/4" (6)
3-3/
8" (8
6)
7/8" (22)
1/4" (6)
3-1/8" (79) Clear Glass Width
Horizontal Section
Jamb Jamb
Vertical Section
Sill
Head
Springline™
Springline™ Flanker
13-11
C a s e m e n t & A w n i n g W i n d o w s
A r C h i t e C t u r A l D e t A i l F i l er e v . 0 2 / 0 8
Basic Unit Details
French Casement Aluminum Clad Venting Windows — Rectangular DetailsScale 3" = 1'-0" (1:4)
Minimum Rough Opening Width
Unit Dimension Width
Unobstructed Glass Width Unobstructed Glass Width
1/4" (6) 1/4" (6)
3-1/8" (79)
1-5/16" (33)
1-1/8" (29)
7/8"(22)
6-1/8" (156)
3-3/
8" (8
6)
4-9/
16"
(116
) Jam
b W
idth
3-1/8" (79)
1-5/16" (33)3-3/8" (86)
4-9/16" (116) Jamb Width
1-1/8" (29)
1-1/8" (29)
1-1/8"(29)
1-7/16"(37)
Min
imum
Rou
gh O
peni
ng H
eigh
t
Unit
Dim
ensi
on H
eigh
t
Unob
stru
cted
Gla
ss H
eigh
t
Clea
r Ope
ning
Hei
ght*
1/4" (6)
1/4" (6)
3-1/
8" (7
9)3-
1/8"
(79)
JambJamb Meeting Rail
Sill
Head
Optional extension jambs
Multi-point locking handle
Insect screen* See page 13-18 for Clear Opening information
Optional extension jambs
Insect screen
Horizontal Section
Vertical Section
SillSingle Glazed Option
SillDecorative Triple Glazed Option
Minimum Rough Opening
rough opening dimensions shown are the minimum dimensions recommended for proper installation. these dimensions may need to be increased to allow for use of building wraps, flashing, sill or pan
flashing, brackets, fasteners or other items which could decrease these dimensions. Adjusting rough opening dimensions to accommodate these materials is the responsibility of the designer or installer.
13-12
C a s e m e n t & A w n i n g W i n d o w s
A r C h i t e C t u r A l D e t A i l F i l e r e v . 0 2 / 0 8
Basic Unit Details
French Casement Aluminum Clad Venting Windows — Archtop DetailsScale 3" = 1'-0" (1:4)
Minimum Rough Opening Width
Unit Dimension Width
Unobstructed Glass Width Unobstructed Glass Width
1/4" (6) 1/4" (6)
3-1/8" (79)
1-5/16" (33)
1-1/8"(29)
7/8"(22)
6-1/8" (156)
3-3/
8" (8
6)
4-9/
16"
(116
) Jam
b W
idth
3-1/8" (79)
JambJamb Meeting Rail
Min
imum
Rou
gh O
peni
ng H
eigh
t
Unit
Dim
ensi
on H
eigh
t
Unob
stru
cted
Gla
ss H
eigh
t
1-5/16" (33)3-3/8" (86)
4-9/16" (116) Jamb Width
1/4" (6)
1/4" (6)
3-1/
8" (7
9)3-
1/8"
(79)
Sill
Head
Vertical Section
Horizontal Section
7/8" (22)
Optional interior casing
1-1/8" (29)
1-1/8"(29)
1-7/16"(37)
Clea
r Ope
ning
Hei
ght*
Optional extension jambs
Insect screen
Optional extension jambs
Insect screen
Multi-point locking handle
SillSingle Glazed Option
SillDecorative Triple Glazed Option
* See page 13-18 for Clear Opening information
Minimum Rough Opening
rough opening dimensions shown are the minimum dimensions recommended for proper installation. these dimensions may need to be increased to allow for use of building wraps, flashing, sill or pan
flashing, brackets, fasteners or other items which could decrease these dimensions. Adjusting rough opening dimensions to accommodate these materials is the responsibility of the designer or installer.
13-13
C a s e m e n t & A w n i n g W i n d o w s
A r C h i t e C t u r A l D e t A i l F i l er e v . 0 2 / 0 8
Basic Unit Details
French Casement Aluminum Clad Venting Windows — Springline™ Window DetailsScale 3" = 1'-0" (1:4)
Minimum Rough Opening Width
Unit Dimension Width
Unobstructed Glass Width Unobstructed Glass Width
1/4" (6) 1/4" (6)
3-1/8" (79)
1-5/16" (33)
1-1/8" (29)
7/8"(22)
6-1/8" (156)
3-3/
8" (8
6)
4-9/
16"
(116
) Jam
b W
idth
3-1/8" (79)
JambJamb Meeting Rail
Min
imum
Rou
gh O
peni
ng H
eigh
t
Unit
Dim
ensi
on H
eigh
t
Unob
stru
cted
Gla
ss H
eigh
t
1-5/16" (33)3-3/8" (86)
4-9/16" (116) Jamb Width
1/4" (6)
1/4" (6)
3-1/
8" (7
9)3-
1/8"
(79)
Sill
Vertical Section
Horizontal Section
Head
7/8" (22)
Optional interior casing
1-1/8" (29)
1-1/8"(29)
1-7/16"(37)
Clea
r Ope
ning
Hei
ght*
Optional extension jambs
Insect screen
Optional extension jambs
Insect screen
Multi-point locking handle
SillSingle Glazed Option
SillDecorative Triple Glazed Option
* See page 13-18 for Clear Opening information
Minimum Rough Opening
rough opening dimensions shown are the minimum dimensions recommended for proper installation. these dimensions may need to be increased to allow for use of building wraps, flashing, sill or pan
flashing, brackets, fasteners or other items which could decrease these dimensions. Adjusting rough opening dimensions to accommodate these materials is the responsibility of the designer or installer.
13-14
C a s e m e n t & A w n i n g W i n d o w s
A r C h i t e C t u r A l D e t A i l F i l e r e v . 0 2 / 0 8
Basic Unit Details
French Casement Aluminum Clad Fixed Windows — Rectangular DetailsScale 3" = 1'-0" (1:4)
Minimum Rough Opening
rough opening dimensions shown are the minimum dimensions recommended for proper installation. these dimensions may need to be increased to allow for use of building wraps, flashing, sill or pan
flashing, brackets, fasteners or other items which could decrease these dimensions. Adjusting rough opening dimensions to accommodate these materials is the responsibility of the designer or installer.
A r C h i t e C t u r A l D e t A i l F i l er e v . 0 2 / 0 8
Basic Unit Details
French Casement Aluminum Clad Fixed Windows — Archtop DetailsScale 3" = 1'-0" (1:4)
Minimum Rough Opening
rough opening dimensions shown are the minimum dimensions recommended for proper installation. these dimensions may need to be increased to allow for use of building wraps, flashing, sill or pan
flashing, brackets, fasteners or other items which could decrease these dimensions. Adjusting rough opening dimensions to accommodate these materials is the responsibility of the designer or installer.
A r C h i t e C t u r A l D e t A i l F i l e r e v . 0 2 / 0 8
Basic Unit Details
French Casement Aluminum Clad Fixed Windows — Springline™ Window DetailsScale 3" = 1'-0" (1:4)
Minimum Rough Opening
rough opening dimensions shown are the minimum dimensions recommended for proper installation. these dimensions may need to be increased to allow for use of building wraps, flashing, sill or pan
flashing, brackets, fasteners or other items which could decrease these dimensions. Adjusting rough opening dimensions to accommodate these materials is the responsibility of the designer or installer.
A r C h i t e C t u r A l D e t A i l F i l er e v . 0 2 / 0 8
Minimum Rough Opening Width
Unit Dimension Width
Unobstructed Glass Width
1/4" (6) 1/4" (6)
3-1/8" (79)
1-5/16" (33)
1-1/8" (29)
1-1/8" (29)
3-3/
8" (8
6)
4-9/
16"
(116
) Jam
b W
idth
3-1/8" (79)
1-5/16" (33)3-3/8" (86)
4-9/16" (116) Jamb Width
1-1/8" (29)
1-1/8" (29)
1-1/8" (29)
1-7/16" (37)
Min
imum
Rou
gh O
peni
ng H
eigh
t
Unit
Dim
ensi
on H
eigh
t
Unob
stru
cted
Gla
ss H
eigh
t
1/4" (6)
1/4" (6)
3-1/
8" (7
9)3-
1/8"
(79)
JambJamb
Optional extension jambs
Insect screen
Optional extension jambs
Insect screen
Sill
Head
Vertical Section
Horizontal Section
SillSingle Glazed Option
SillDecorative Triple Glazed Option
Clear OpeningWidth
Basic Unit Details
Awning Aluminum Clad Venting Windows — Unit DetailsScale 3" = 1'-0" (1:4)
Minimum Rough Opening
rough opening dimensions shown are the minimum dimensions recommended for proper installation. these dimensions may need to be increased to allow for use of building wraps, flashing, sill or pan
flashing, brackets, fasteners or other items which could decrease these dimensions. Adjusting rough opening dimensions to accommodate these materials is the responsibility of the designer or installer.
Clear Opening Detail Scale 1-1/2" = 1'-0" (1:8)
13-18
C a s e m e n t & A w n i n g W i n d o w s
A r C h i t e C t u r A l D e t A i l F i l e r e v . 0 2 / 0 8
A r C h i t e C t u r A l D e t A i l F i l er e v . 0 2 / 0 8
Clear Opening Details
Rectangular Units Scale 1-1/2" = 1'-0" (1:8)
Concealed Hinge 90° Opening(units less than 2-7 1/2" wide)
Concealed Hinge 20" Limited Opening(units equal to or greater than 2-7 1/2" wide)
Clear Opening Width
Clear O
pening
Width
Unit Width
6-11/16" (170) 2-1/16"(52)
2'-7 1/2" (800)
Clea
r Ope
ning
Hei
ght
Clea
r Ope
ning
Hei
ght
13-20
C a s e m e n t & A w n i n g W i n d o w s
A r C h i t e C t u r A l D e t A i l F i l e r e v . 0 2 / 0 8
Clear Opening Details
Shaped Units Scale 1-1/2" = 1'-0" (1:8)
Clear Opening Width
Unit Width Unit Width
Butt Hinge 20" Limited Opening(units equal to or greater than 2-7 1/2" wide)
Butt Hinge 45° Opening(units less than 1'-8 1/2" wide)
Butt Hinge 90° Opening(units 1'-8 1/2" to units less than 2-7 1/2" wide)
Butt Hinge 70° Opening(Springline™ and Springline™ flanker units)
Unit Width Unit Width
3-1/16"(78)
Clear
Openin
g Widt
h
Clear Opening W
idth
Clear O
pening Width
Clea
r Ope
ning
Heig
ht
Archtop Unequal Leg Archtop Springline™ Springline™ FlankerTrapezoid
Clea
r Ope
ning
Hei
ght
Clea
r Ope
ning
Hei
ght
Clea
r Ope
ning
Hei
ght
Clea
r Ope
ning
Hei
ght
2-1/16"(52)
13-21
C a s e m e n t & A w n i n g W i n d o w s
A r C h i t e C t u r A l D e t A i l F i l er e v . 0 2 / 0 8
Clear Opening With Both Sash Open
Clear Opening With Both Sash Open
Butt Hinge 70° Opening(Springline™)
Butt Hinge 90° Opening(Rectangle and Archtop)
Clea
r Ope
ning
Hei
ght
Clea
r Ope
ning
Hei
ght
Clea
r Ope
ning
Heig
ht
Clear Opening Details
French Casement Units Scale 1-1/2" = 1'-0" (1:8)
13-22
C a s e m e n t & A w n i n g W i n d o w s
A r C h i t e C t u r A l D e t A i l F i l e r e v . 0 2 / 0 8
Suggested Product Applications
Vertical SectionBrick veneer / 2 x 6" Metal Stud Framing
Vertical SectionWood Siding / 2 x 4 Wood Stud Framing
Vertical Sectione.i.F.S. / Concrete Masonr y unit (CMu)
Wall Types Scale 1-1/2" = 1'-0" (1:8)
Min
imum
Rou
gh O
peni
ng H
eigh
t
Unit
Dim
ensi
on H
eigh
t
Rgh.
Opg
.W
idth
1/4"(6)
Unit
Dim
.W
idth
Sill
Jamb
Head
Flangeall around
Installationflange all around
Head
Jamb
Sill
Unit
Dim
ensi
on H
eigh
t
Min
imum
Rou
gh O
peni
ng H
eigh
t
Rgh.
Opg
. W
idth
1/4" (6)
Unit
Dim
. W
idth
*1/2" (13) minimum to accommodate differential shrinkage/expansion when brick is applied to wood framing.
1/2" (13)* minimum
Removeflange at head
Unit
Dim
ensi
on H
eigh
t
Rgh.
Opg
.W
idth
Unit
Dim
.W
idth
1/4"(6)
Min
imum
Rou
gh O
peni
ng H
eigh
t
Flange allaround
Head
Jamb
Sill
Membrane flashing over flange(by others)
Minimum Rough Openingrough opening dimensions shown are the minimum dimensions recommended for proper installation. these dimensions may need to be increased to allow for use of building wraps, flashing, sill or pan flashing, brackets, fasteners or other items which could decrease these dimensions. Adjusting rough opening dimensions to accommodate these materials is the responsibility of the designer or installer.
Importance of Proper InstallationProper installation and maintenance of Andersen® products are essential if optimum performance is to be fully attained. Written installation instructions which provide guidelines for proper installation are available for Andersen products from your local Andersen supplier or by writing to: Andersen Windows, inc., Box 12, Bayport, MN 55003 or by visiting our website at www.andersenwindows.com. remember that every installation is different. Andersen strongly recommends consultation with an Andersen product representative and with an experienced contractor, architect, or structural engineer prior to the installation of any Andersen product.
Construction by OthersAndersen Corporation is not responsible for the design of, conditions in, or performance of, adjacent wall or roof construction beyond the perimeter of the Andersen units.
NOte: Where e.i.F.S. wall finish is adjacent to units, contact e.i.F.S. manufacturer for installation instructions, including the use of appropriate flashing, the proper use of sealant and backer rod, and the proper width of sealant joint around the perimeter of
the unit.
NOte: leave adequate clearance between sill and masonry for caulking and dimensional change of framework. Flange may be
removed where construction sequence/ detailing requires no flange.
13-23
C a s e m e n t & A w n i n g W i n d o w s
A r C h i t e C t u r A l D e t A i l F i l er e v . 0 2 / 0 8
Suggested Product Applications
Vertical SectionBrick / Concrete Masonr y unit (CMu)
Vertical SectionStucco / Concrete Masonr y unit
(CMu) inset Window
Vertical Sectionexisting Stud Wall
Wall Types Scale 1-1/2" = 1'-0" (1:8)
Unit
Dim
ensi
on H
eigh
t
1/4" (6)
Unit
Dim
.W
idth
Rgh.
Opg
.W
idth
Flange at sill & side jambs
Min
imum
Rou
gh O
peni
ng H
eigh
t
Jamb
Head
Sill
Remove flange athead
Head
Jamb
Sill Un
it Di
men
sion
Hei
ght
Trim flanges at headand jambs
Removeflangeat sill
1/4" (6)
Unit
Dim
. W
idth
Optional extension jambs
Rgh.
Opg
. W
idth
Min
imum
Rou
gh O
peni
ng H
eigh
t
Unit
Dim
ensi
on H
eigh
t
Rgh.
Opg
.W
idth
Unit
Dim
.W
idth
1/4"(6)
Min
imum
Rou
gh O
peni
ng H
eigh
t
Existing wall
Optionalextention jambs
Flangeall around
Head
Jamb
Sill
Exterior trimby others
Minimum Rough Openingrough opening dimensions shown are the minimum dimensions recommended for proper installation. these dimensions may need to be increased to allow for use of building wraps, flashing, sill or pan flashing, brackets, fasteners or other items which could decrease these dimensions. Adjusting rough opening dimensions to accommodate these materials is the responsibility of the designer or installer.
Importance of Proper InstallationProper installation and maintenance of Andersen® products are essential if optimum performance is to be fully attained. Written installation instructions which provide guidelines for proper installation are available for Andersen products from your local Andersen supplier or by writing to: Andersen Windows, inc., Box 12, Bayport, MN 55003 or by visiting our website at www.andersenwindows.com. remember that every installation is different. Andersen strongly recommends consultation with an Andersen product representative and with an experienced contractor, architect, or structural engineer prior to the installation of any Andersen product.
Construction by OthersAndersen Corporation is not responsible for the design of, conditions in, or performance of, adjacent wall or roof construction beyond the perimeter of the Andersen units.
NOte: Where e.i.F.S. wall finish is adjacent to units, contact e.i.F.S. manufacturer for installation instructions, including the use of appropriate flashing, the proper use of sealant and backer rod, and the proper width of sealant joint around the perimeter of
the unit.
NOte: leave adequate clearance between sill and masonry for caulking and dimensional change of framework. Flange may be
removed where construction sequence/ detailing requires no flange.