Contactors and Contactor Assemblies
Siemens Energy & Automation, Inc.Industrial Controls Catalog
For size S0:a = 3 mm at < 240 Va = 7 mm at > 240 Vb = DC 10 mm deeper than AC1) Auxiliary switch block, laterally mountable2) Auxiliary switch block, mountable on the front,
For size S0:a = 0 mm with varistor < 240 V, diode assemblya = 3.5 mm with varistor > 240 Va = 17 mm with RC elementb = DC 15 mm deeper than AC1) Auxiliary switch block, laterally mountable2) Auxiliary switch block, mountable on the front
(1, 2 and 4-pole)3) Surge suppressor4) Drilling pattern
For size S2:a = 0 mm with varistor < 240 V, diode assemblya = 3.5 mm with varistor > 240 Va = 17 mm with RC elementb = DC 15 mm deeper than AC1) Auxiliary switch block, laterally mountable2) Auxiliary switch block, mountable on the front
(1, 2 and 4-pole)3) Surge suppressor4) Drilling pattern
3RTSizewith
3RTSizewithand
06IC02_177-200.qxd 12/2/05 11:32 AM Page 2/178
2/179
Contactors and Contactor Assemblies
Siemens Energy & Automation, Inc.Industrial Controls Catalog
For size S2:a = 0 mm with varistor < 240 V, diode assemblya = 3.5 mm with varistor > 240 Va = 17 mm with RC elementb = DC 15 mm deeper than AC1) Auxiliary switch block, laterally mountable2) Auxiliary switch block, mountable on the front
(1, 2 and 4-pole)3) Surge suppressor4) Drilling pattern
For size S3:a = 0 mm with varistor, diode assembly
and < 240 Va = 3.5 mm with varistor and > 240 Va = 17 mm with RC elementb = DC 13 mm deeper than AC
1) Auxiliary switch block, laterally mountable2) Auxiliary switch block, mountable on the
front (1, 2 and 4-pole), same dimensions for designs with screw or Cage Clamp con-nection
3) Surge suppressor4) Drilling pattern5) For mounting on 35 mm standard mounting
rail (15 mm deep) acc. to EN 50 022or 75 mm standard mounting rail acc. toEN 50 023
6) Hexagon socket screw 4 mm
06IC02_177-200.qxd 12/2/05 11:33 AM Page 2/179
SiemIndus
2/180
3RT10 NEMA labeled contactors,3-pole
Contactors and Contactor Assemblies
Siemens Energy & Automation, Inc.Industrial Controls Catalog
SIRIUS
Siemens / Industrial Controls Previous folio: Sirius Nema Rated.pdf, 2/179
3RT1017 contactor
NEMA Size 0, screw connection
With surge suppressor, auxiliary switch block and mounted overload relay
3RT1026 contactor
NEMA Size 1, screw connection
With surge suppressor, auxiliary switch blocks and mounted overload relay
3RT1036 contactor
NEMA Size 2, screw connection
With surge suppressor, auxiliary switch blocks and mounted overload relay
Deviating dimensions for coupling relayswith Cage Clamp connection:Height: 60 mm
3) Surge suppressor4) Drilling pattern
Dimension drawings
For size S3:a = 0 mm with varistor, diode assembly
and < 240 Va = 3.5 mm with varistor and > 240 Va = 17 mm with RC elementb = DC 13 mm deeper than AC1) Auxiliary switch block, laterally mountable2) Auxiliary switch block, mountable on the
front (1, 2 and 4-pole), same dimensions for designs with screw or Cage Clamp con-nection
3) Surge suppressor4) Drilling pattern5) For mounting on 35 mm standard mounting
rail (15 mm deep) acc. to EN 50 022or 75 mm standard mounting rail acc. toEN 50 023
6) Hexagon socket screw 4 mm
3RT10 contactors,3-pole