951 Old Rand Rd Suite 116 Wauconda IL 60084 P 847-487-5599 F 847-487-0909 www.midwest-control.com TECHNICAL DATA Conrader Control Valves Technical Data Effective 4-4-2011 R1 Safety Valves Soft Seat ................................................................................ 2 , 3 Safety Valves Hard Seat…. .................................................................... ……..3, 4 Safety Valves Non Code ................................................................................. 4, 5 Relief Valves ......................................................................................................... 5 Stainless Steel Safety Valves ............................................................................. 6 In Tank Check Valves .................................................................................. 7,8,9 In Line Check Valves...................................................................................... 9,10 Pilot Unloader Valves ................................................................................. 11,12 Pilot Valves - Non Vented ................................................................................. 13 Pilot Valves - Vented ......................................................................................... 14 Discharge Valves, Cold Start ......................................................................... 15 Carry Tank Manifold, Service Manifold. ........................................................ 16 Pressure Control Regulator ............................................................................. 16 Filler Valve, Drain Cocks ........................................................................... 17,18 Automatic Tank Drain ...................................................................................... 18 Smart Start, Shuttle Valve .............................................................................. 19 Throttle Controls and Accessories ................................................................. 20 Safety Valve Capacity Chart ..................................................................... 21,22
22
Embed
Conrader Control Valves Technical Data - Hydra Flow … Old Rand Rd Suite 116 Wauconda IL 60084 P 847-487-5599 F 847-487-0909 TECHNICAL DATA Conrader Control Valves Technical Data
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
951 Old Rand Rd Suite 116 Wauconda IL 60084
P 847-487-5599 F 847-487-0909
www.midwest-control.com
TEC
HN
ICA
L D
ATA
Conrader Control Valves Technical Data
Effective 4-4-2011 R1
Safety Valves Soft Seat ................................................................................ 2 , 3 Safety Valves Hard Seat…. .................................................................... ……..3, 4 Safety Valves Non Code ................................................................................. 4, 5 Relief Valves ......................................................................................................... 5 Stainless Steel Safety Valves ............................................................................. 6 In Tank Check Valves .................................................................................. 7,8,9 In Line Check Valves ...................................................................................... 9,10 Pilot Unloader Valves ................................................................................. 11,12 Pilot Valves - Non Vented ................................................................................. 13 Pilot Valves - Vented ......................................................................................... 14 Discharge Valves, Cold Start ......................................................................... 15 Carry Tank Manifold, Service Manifold. ........................................................ 16 Pressure Control Regulator ............................................................................. 16 Filler Valve, Drain Cocks ........................................................................... 17,18 Automatic Tank Drain ...................................................................................... 18 Smart Start, Shuttle Valve .............................................................................. 19 Throttle Controls and Accessories ................................................................. 20 Safety Valve Capacity Chart ..................................................................... 21,22
• Construction: Seat Cap & Piston C360 Brass ( ASTM B-16) 17-7 Stainless Steel Spring, Silicone Seal
• Bubble Tight to Within 5 psig for Set pressure 50 psig or Less, Bubble Tight to Within 10% for Set Pressures Greater Than 50 psig. 100% Testing or 2.5 AQL Sample Testing, Conforming to AP1 527
• Stamped with the UV and NB Symbols
• Everseal 483 Sealant Standard
• Available Size: 1/2” (BSPT Threads Available)
SRV187 ASME SOFT SEAT SAFETY VALVE
• Applications: Compact Size Low Flow
• Stock Pressure Range: 75, 125, 145, 150, 165, 200, 225 Other Pressures Available Up to 250 psig
• Set Pressure Tolerances: ± 3% of Set Pressure
• Temperature Range: -65˚F to 400˚F
• Construction: Seat Cap & Piston C360 Brass ( ASTM B-16) 17-7 Stainless Steel Spring, Silicone Seal
• Bubble Tight to Within 5 psig for Set pressure 50 psig or Less, Bubble Tight to Within 10% for Set Pressures Greater Than 50 psig. 100% Testing or 2.5 AQL Sample Testing, Conforming to AP1 527
• Stamped with the UV and NB Symbols
• Everseal 483 Sealant Standard
• Available Size: 1/4” (BSPT Threads Available)
SRV ASME SOFT SEAT SAFETY VALVE • Applications: Small Air Compressors with High Flow Requirements
• Pressure Range: 25 to 450 PSI
• Set Pressure Tolerances: ± 3% of Set Pressure
• Temperature Range : -65˚F to 400˚F
• Construction: Seat Cap & Piston C360 Brass ( ASTM B-16) 17-7 Stainless Steel Spring, Silicone Seal
• Bubble Tight to Within 5 psig for Set pressure 50 psig or Less, Bubble Tight to Within 10% for Set Pressures Greater Than 50 psig. 100% Testing or 2.5 AQL Sample Testing, Conforming to AP1 527
• Stamped with the UV and NB Symbols
• Everseal 483 Sealant Standard
• Available Sizes: 1/8”, 1/4”, and 3/8” (BSPT Threads Available)
• No Audible Leak at 45% Set Pressure at 25-74 psig No Audible Leak at 90% Set Pressure Above 74 psig
• Stamped with UV and NB Symbols
• Everseal 483 Sealant Standard
• Available Sizes: SRH580-75 3/4”, SRH580-10 1” (BSPT Threads Available)
Part No. Height (In)
Hex (In)
Wt. Lbs.
SRH580-75 5.04 1-3/16
SRH580-10 .717
5.35 1-3/8
CVR VACUUM RELIEF VALVE • Applications: Used in Systems to Maintain a Desired Vacuum Level
• Relief Valves are Proportional - Not “Pop” Type Safety Valves Not Preset - Field Adjustable
• Knurled Adjustment Screw & Locked with Jam Nut
• Pressure Range: 0-27” Hg
• Temperature Range: -65˚F to 250˚F
• Construction: C360 Machined Brass Body, Stainless Steel Spring, Nylon Piston, Nitrile Seal (CVR-25 - Stainless Steel Piston and Seal)
• Bubble Tight to Within 5 psig for Set pressure 50 psig or Less, Bubble Tight to Within 10% for Set Pressures Greater Than 50 psig. 100% Testing or 2.5 AQL Sample Testing, Conforming to AP1 527
• Available Sizes: 1/4”, 3/8”, 3/4”, 1” & BSPT Threads
• Everseal 483 Sealant Standard
951 Old Rand Rd Suite 116 Wauconda IL 60084
P 847-487-5599 F 847-487-0909
www.midwest-control.com
TEC
HN
ICA
L D
ATA
Part No. PSI Range
CNC25-001 Adjustable 25—50
CNC25-002 Adjustable 51-100
CNC25-003 Adjustable 101-150
CNC25-004 Adjustable 151-200
CNC25-K Kit Includes Safety Valve and All Spring Sizes
CNC NON CODE RELIEF VALVE • Applications: Non Code Safety Valve Field Adjustable
• Knurled Thumbscrew & Jam Nut Make Adjustments Easy & Repeatable
• Bubble Tight to Within 5 psig for Set pressure 50 psig or Less, Bubble Tight to Within 10% for Set Pressures Greater Than 50 psig. 100% Testing or 2.5 AQL Sample Testing, Conforming to AP1 527
• Everseal 483 Sealant Standard • Available Size: 1/4”
CVR-25 1/4HP
CVR-38 1HP
CVR-75 3HP
CVR-10 5HP
Max. Recommended Vacuum Pump Size
Part No. NPT (In)
Available Pressure Range
(PSI)
Flow @ 5 PSI Crack
Pressure
CPR-25 1/4 10-60
50-125 100-200
2
CPR-38 3/8 0-20 5
CPR-75 3/4 0-20
CPR-10 1 0-20 10
CPR SOFT SEAT RELIEF VALVE • Applications: Use in Systems to Maintain Desired Pressure Level
• Proportional Relief Valves - Not “Pop” Type Safety Valves Not Preset - Field Adjustable
• Knurled Adjustment Screw & Locked with Jam Nut
• Temperature Range: -65˚F to 250˚F
• Construction: C360 Machined Brass Body Stainless Steel Spring, Nylon Piston, Nitrile Seal (CPR-25 - Stainless Steel Piston and Seal)
• Bubble Tight to Within 5 psig for Set pressure 50 psig or Less, Bubble Tight to Within 10% for Set Pressures Greater Than 50 psig. 100% Testing or 2.5 AQL Sample Testing, Conforming to AP1 527
• Available Sizes: 1/4”, 3/8”, 3/4”, 1” & BSPT Threads
• Everseal 483 Sealant Standard
5
MCNC25-K
Height (In) Hex ( In) Wt. Lbs
1.74 .625 .100
951 Old Rand Rd Suite 116 Wauconda IL 60084
P 847-487-5599 F 847-487-0909
www.midwest-control.com
6
SRH250-SS ASME HARD SEAT STAINLESS STEEL SAFETY VALVE
• Applications: Higher Temperature i.e. After coolers & Intercoolers
• Valves are 100% Tested for Backflow Leakage Performance
• 1 PSI Cracking Pressure
• Maximum Pressure: 500 PSI
• Maximum Temperature: 450˚ F
• 1/8” Tapped Port is Standard
• Everseal 483 Sealant Standard
8
951 Old Rand Rd Suite 116 Wauconda IL 60084
P 847-487-5599 F 847-487-0909
www.midwest-control.com
Applications: Compressor Applications Where an In Tank Check Valve Will Not Fit, the CLB Valve Can Conveniently be Installed Right in the Discharge Line of the Compressor
• Valves are 100% Tested for Backflow Leakage Performance
• 1 PSI Cracking Pressure
• Maximum Pressure: 500 PSI
• Maximum Temperature: 450˚ F
• 1/8” Tapped Port is Standard
• Everseal 483 Sealant Standard
B A
• Construction: C360 Machined Brass Body, and Cap, Viton O-Ring, and Nitrile Disc
• 1 PSI Cracking Pressure
• Maximum Pressure 500 PSI
• Maximum Temperature: 300˚F
IN LINE CHECK VALVES CLC SERIES LOW FLOW APPLICATIONS
CLB
CLC
9
TEC
HN
ICA
L D
ATA
(Plug Not Shown)
Part No. Inlet (In)
Outlet (In)
Hex (In)
Length (In)
Flow Rate
Wt Oz.
CLS2525 1/4 MNPT
1/4 MNPT
5/8 1.34 9 2
CLS2550 1/4 MNPT
1/2 MNPT
.875 1.34 9 2.4
CLSF2525 1/4 MNPT
1/4 FMPT
11/16 1.34 9 3
IN LINE CHECK VALVES CSL & CLSF SERIES • Applications: Tank Check Valves for Small Air Compressors or Components in Pneumatic Circuits
• Pressure Range: 250 PSI
• Maximum Temperature: 350˚F
• Construction:C360 Machined Brass Body With Viton® O Rings, Brass Poppet and Washer , Stainless Steel Spring
• Bubble Tight Sealing Capabilities at Low Pressure Drops
• Everseal 483 Sealant Standard
951 Old Rand Rd Suite 116 Wauconda IL 60084
P 847-487-5599 F 847-487-0909
www.midwest-control.com
Part No. FPT
Inlet (In)
Length
(In)
Height (In)
Width (In)
Recommend Max Flow Rate
SCFM
Wt. Oz.
GV18 1/8 1.76 1.78 1.04 12 5.12
GV25 1/4
GV38 3/8 1.85 1.81 1.13 22 6.02
GV50 1/2 2.28 2.24 1.44 38 10.21
GV75 3/4 2.54 2.39 1.62 60 12.19
GV10 1 3.00 2.68 1.97 115 23.10
GV12 1-1/4 3.60 3.33 2.38 38.50
GV15 1-1/2 3.97 3.43 2.75 51.97
GV20 2 4.91 4.00 3.32 220 90.38
160
IN LINE CHECK VALVES VERTICAL OR HORIZONTAL GV SERIES
• Applications: Air Compressor Discharge Lines
• Construction: Bronze Body, Corrosion Resistant Stainless Steel Spring to Ensure Long Life, 15% Glass Filled Teflon Poppet, C360 Machined Brass Cap, 1/8 NPT Unloader Port is Standard
• Pressure Range: 250 PSI
• Maximum Temperature: 450˚F
• Cracking Pressure: 3 PSI
• Repairable
10
CLS
CLSF Series
951 Old Rand Rd Suite 116 Wauconda IL 60084
P 847-487-5599 F 847-487-0909
www.midwest-control.com
Part No. Flow
NSG 30
NG 30
NLG-1 60
PILOT UNLOADER VALVES
TEC
HN
ICA
L D
ATA
• Application: Self Contained Unloading Valve Can Be Used Wherever a Continuous Run Air Compressor Is Required
• Combines All Components Required for Continuous Run Compressors: Pilot Valve, Vent Valve and Check Valve
• Eliminates the Need for Built in Head Unloaders
• Easy Installation: Install the Piloted Unloader Valve into the Receiver and Attach the Compressor Discharge Line to the Valve Inlet
• Factory Preset Cut- In : Cut- Out: Pressure (Standard) 95 – 115, Optional High Pressure 145 - 175 Minimum Cut- In: 40 PSI Maximum Cut- Out: 250 PSI Can be Field Adjusted
• Construction: Forged Brass Body, 15% Glass Filled Teflon CV Piston and Unloader, 302 Stainless Steel Spring, and Pilot Valve Ball
• Tapped & Plugged 1/8” Port for Throttle Control of a Gas Engine
• 1/8” NPT Tapped Port for Pressure Switch Unloader Valve and Vent Port Muffler
• A Toggle Unloading Lever for One Hand Warm Up Control
• Muffler Included (Not Shown) for Models NSG, NG
• Optional Muffler EM-50 Available for Model NLG
• Optional Inlet and Outlet Ports Available— Consult Price List
• Optional Provisions to Add a Safety Valve Port - Consult Price List
11
PILOTED UNLOADER VALVE NSG
Vent 1/4 NPT Female
Outlet Port
Throttle Control Port
Inlet Port
Alternate Inlet Port Opposite Throttle Control Port
951 Old Rand Rd Suite 116 Wauconda IL 60084
P 847-487-5599 F 847-487-0909
www.midwest-control.com
12
5.25
2.54
3.16
4.09
PILOT UNLOADER VALVE NG
PILOT UNLOADER VALVE NLG-1
Throttle Control Port
Optional Inlet Ports
Vent 3/8 NPT Female
Outlet Port
Inlet Port
Vent 1/2 NPT Female
Outlet Port
Throttle Control Port
T
ECH
NIC
AL
DA
TA
951 Old Rand Rd Suite 116 Wauconda IL 60084
P 847-487-5599 F 847-487-0909
www.midwest-control.com
13
RCT-HU w/Hand Unloader
RCQ-HU w/ Hand Unloader
RCB-HU w/Hand Unloader
UNLOADER PILOT VALVES, NON VENTING STYLE
Unloader Pilot Valves are Used In Compressed Air Systems to Actuate Another Device Using a Pneumatic (Air) Signal. Unloader Pilot Valves Always Work in Conjunction with Another Device. Pilot Valves Operate in a Set Pressure Range. The Range has an Unload Setting and a Load Setting. As a Compressor Operates in This Range, It is Said to Be Cycling. At the Unload Setting the Pilot Valves Opens and Actuates Another Device (Throttle Control, Discharge Valve). At the Load Setting the Pilot Valve Closes and Returns the Compressor to Normal Operation.
RCL-HU w/Hand Unloader
RCB-DC w/Dual Control
*** Other Cut In—Cut Out Settings Available Consult Midwest Control
Part No. Cut In Cut Out Inlet Outlet
PILOT VALVE WITH HAND UNLOADER AND MOUNTING BOSS 1/4 F x 1/8 F RCT-HU95-115 95 115
1/4 Female 1/8 Female RCT-HU145-175 145 175
PILOT VALVE WITH HAND UNLOADER 1/4 F x 1/8 F RCB-HU95-115 95 115
1/4 Female 1/8 Female RCB-HU145-175 145 175
PILOT VAVLE WITH STRAIGHT STEM START STOP OPERATION 1/4 M x 1/8 F RCBM-95-115 95 115 1/4 Male 1/8 Female
PILOT VALVE WITH HAND UNLOADER 1/4 M x 1/8 F
RCBM-HU95-115 95 115 1/4 Male 1/8 Female
RCBM-HU145-175 145 175
PILOT VALVE WITH HAND UNLOADER 3/8 F x 1/4 F RCL-HU125-150 125 150
3/8 Female 1/4 Female RCL-HU145-175 145 175
PILOT VALVE WITH HAND UNLOADER (Typically Used on Quincy Compressors) 1/4 F x 1/4 F RCQ-HU100-110 100 110
1/4 Female 1/4 Female RCQ-HU180-200 180 200
PILOT VALVE WITH DUAL CONTROL 1/4 F x 1/8 F RCB-DC95-115 95 115
1/4 Female 1/8 Female RCB-DC145-175 145 175
PILOT VALVE WITH DUAL CONTROL 3/8 F x 1/4 F RCL-DC100-125 100 125
3/8 Female 1/4 Female RCL-DC145-175 145 175
Typical Applications
• Actuating a Throttle Control to Slow Down and Speed Up an Engine
• Opening and Closing a Discharge Valve to Vent Air to Atmosphere
• Operating the Intake Unloaders in the Compressor Head
• Construction: C360 Machined Brass Body, Music Wire Spring, Stainless Steel Pilot Valve Ball
• Maximum Temperature: 350˚F
• Field Adjustable (For All Models Except RCL, RCLD)
• Minimum Cut- In Pressure: 40 PSI
• Maximum Cut- Out Pressure: 250PSI For RCL, RCLD
• Minimum Cut- In Pressure: 20 PSI
• Maximum Cut- Out Pressure: 1200 PSI
Dual Control - Hand Unloader
• The Hand Unloader is Typically Used to Manually Unload the Compressor
• Dual Control is Typically Used on Electric Compressors to Select From Stop Start to Constant Speed Operation
RCBM w/Dual Control
RCL-DC w/ Dual Control
The DC Dual Control is Used On Electric Compressors to Select Start/Stop or Constant Speed Control
Typical Dual Control
951 Old Rand Rd Suite 116 Wauconda IL 60084
P 847-487-5599 F 847-487-0909
www.midwest-control.com
14
BG1 BG2
BE2 BE1
UNLOADER PILOT VALVES, VENTING STYLE
Dual Control - Hand Unloader
• The Hand Unloader is Typically Used to Manually Unload the Compressor
• Dual Control is Typically Used on Electric Compressors to Select From Stop Start to Constant Speed
BLG
Part No. Cut In Cut Out
Discharge Inlet
Pilot Inlet Vent Stem SCFM
Capacity
PILOT VALVE WITH HAND UNLOADER, COMPRESSION DISCHARGE 1/4 C x 1/4 M
BG1-HU95-115 95 115 1/4 Compression
1/4 Male
Direct Unported
Hand Unloader 20
BG1-HU145-175 145 175
PILOT VALVE WITH HAND UNLOADER, FEMALE DISCHARGE 1/4 F x 1/4 M
BG2-HU95-115 95 115 1/4
Female 1/4
Male Direct
Unported Hand
Unloader 20 BG2-HU145-175 145 175
PILOT VALVE WITH DUAL CONTROL FEMALE DISCHARGE 1/4 F x 1/4 M
BE2-110-135 110 135 1/4 Female
1/4 Male
Direct Unported
Dual Control
20
PILOT VALVE WITH DUAL CONTROL COMPRESSION DISCHARGE 1/4 C x 1/4 M
BE1-110-135 110 135 1/4 Compression
1/4 Male
Direct Unported
Dual Control
20
HIGH FLOW PILOT VALVE WITH HAND UNLOADER FEMALE DISCHARGE 1/2 F x 1/4 F
BLG-HU95-115 95 115 1/2 Female
1/4 Female
1/2 Female
Hand Unloader 60
BLG-HU145-175 145 175
Piloted Unloader Valves are Used in Constant Speed Applications Where There are No Intake Unloaders Present. They Incorporate a Discharge Unloader on the Body of a Pilot Valve to Allow One Valve to Sense System Pressure and Vent Discharge Air to Atmosphere. At Load Pressure, the Pilot Valve Closes the Dis-charge Unloader and the Compressor Returns to Normal Operation. Piloted Unloader Valves Require a Separate Check Valve from Which a Line Must be Run to the Discharge Inlet. Optional Muffler Kit Part No. BG-M-KIT Available for BG1 Series (Direct Unported Vent Models)
• Construction: Forged Brass Body, Stainless Steel Spring, and Pilot Ball Valve, 15% Glass Filled Teflon Unloader
• Maximum Temperature: 450ºF (BLE 500ºF)
• Field Adjustable
• Minimum Cut- In Pressure: 40 PSI
• Maximum Cut- Out Pressure: 250 PSI
Typical Connections Discharge Exhaust Unported
Throttle Control Port
Discharge Inlet 1/4 NPT Female
Pilot Inlet 1/4 NPT Male
951 Old Rand Rd Suite 116 Wauconda IL 60084
P 847-487-5599 F 847-487-0909
www.midwest-control.com
15
AUXILIARY UNLOADER (COLD START)
• Application: Bleeds Air From the Compressor Head During the First Few Revolutions, Reducing Motor Starting Torque .
• Typical Applications are Oil Lubed Pumps That are Subject to Low Temperatures and Low Starting Voltages, i.e. a Contractor Unit that May Sit Outside Overnight and be Connected to a Long Extension Cord.
• Construction: C360 Machined Brass Body & Stem, 302 Stainless Steel Spring and Viton O Ring
• Maximum Operating Temperature: 500ºF
• Minimum Close Pressure: 30 PSIG Maximum Close Pressure: 40 PSIG
• Available Sizes: 1/8”, 1/4”
Applications: Constant Speed Applications, Where Intake Unloaders are Not Present The Discharge Valve is Controlled by a Pilot Device that Signals the Normally Closed Valve to Open at the Unload Pressure. When Open, the Discharge Valve Vents the Discharge Line Air to Atmosphere. When System Pressure Drops to Load Pressure, the Pilot Valve Closes the Discharge Valve and the Compressor Returns to Normal Operation
• Applications: Designed to be Installed into the Head of a Small Compressor (Less than 2HP) Direct Drive, Tankless; Where a Variable Pressure Relief Valve is Required
• A Micrometer Type Scale Allows for Easy & Accurate Adjustment from 0-100 PSI
• Construction: Brass body & Internals, Stainless Steel Poppet with Fluorocarbon O-Ring
• Nylon Knob
• Maximum Temperature: 250˚F
• Maximum Flow 6 SCFM at 100 PSI
951 Old Rand Rd Suite 116 Wauconda IL 60084
P 847-487-5599 F 847-487-0909
www.midwest-control.com
16
Inlet Male (In)
Outlet Female
(In)
Gauge Port (In)
Hex (In)
1/2 1/4 1/4 7/8
OAL (In)
1.84
Wt. Oz.
4.8
• Includes a Tank Filler Valve into the Built In Shut Off Valve
• Mates to a Typical Tire Chuck for Easy Tank Pressurization
• Safety Valve is Factory Preset at 150 PSI
• Includes Tank Pressure Gauge Port
Part No. Range
PC-25 10-100 PSI Adjustable
CARRY TANK MANIFOLDS CTM SERIES
SM5590 SERVICE MANIFOLD W/INTEGRAL SAFETY VALVE
Inlet Male (In)
Outlet Female
(In)
Gauge Port (In)
OAL (In)
Wt. Oz.
1/2 1/4 1/4 2.51 4.59
CTM & PC Are Not Manufactured by Conrader
• Applications: Suitable for Compressors 3 Hp & Smaller
• Features Forged Brass Body, Easy Use Shut Off Lever (Ball Valve Type Design w/Stop and Loaded Teflon Seal Which Prevents Leakage) and Stainless Steel Springs
• Includes Pressure Switch Mount & Tank Pressure Gauge Port Which Allows All Control & Outlet Functions to Be Connected to the 1/2” NPT Tank Port
• Stock Pressure for Safety Valve 125,135,150,200 (Custom Pressures Up to 200 PSI Also Available)
• Maximum Temperature: 450ºF
• Everseal 483 Sealant Standard
DRAIN COCKS DT SERIES
• Applications: Designed for Applications where the Traditional Drain cock is Easily Damaged
• Opens Easily and Closes with Minimum Effort
• Construction: Brass Body & Knurled Brass Stem
• Nitrile O-Ring Ensures a Bubble Tight Seal
• Maximum Pressure: 200 PSI
• Maximum Temperature: 250˚F
• Everseal 483 Sealant Standard
• 1/4” Connection
FILLER VALVE TV SERIES • Applications: Use Wherever a Method of Inflating a Tank with a
Standard Air Chuck is Required
• Construction: Brass Valve Core with Viton ® and Teflon ®Seals
• Black Plastic Cap Included
• Maximum Temperature: 250˚F
• Maximum Pressure: 250 PSI
• 1/8” NPT
DRAIN COCKS DCE SERIES • Applications: Compressor Receivers, Radiators and Pool Equipment
Where Stem Removal is Not a Requirement.
• Construction Brass Body & Stem with Zinc Plated Steel Handle
• Maximum Pressure 200 PSI
• Maximum Temperature 200 ˚F
• Everseal 483 Sealant Standard
• Available Sizes: 1/8”, 1/4”, 3/8”, 1/2”
951 Old Rand Rd Suite 116 Wauconda IL 60084
P 847-487-5599 F 847-487-0909
www.midwest-control.com
17
T
ECH
NIC
AL
DA
TA
Part No. NPT (In)
DCE-12 1/8
DCE-25 1/4
DCE-38 3/8
DCE-50 1/2
Part No. Height (In)
TV-12 1.38
TV, DCE & DT Are Not Manufactured by Conrader
An Installation Kit Includes Everything You Need to Get the WV-1 Automatic Tank Drain Up and Running
• The Kit Includes the WV-1 Drain Valve with Push-In Fitting Installed
• Push-to-Connect T, Petcock
• 8 ft. of Nylon Tubing
• Installation Instructions that Cover Most Compressor Applications
AIR AUTOMATIC TANK DRAIN with INSTALLATION KIT WV-1-1K
951 Old Rand Rd Suite 116 Wauconda IL 60084
P 847-487-5599 F 847-487-0909
www.midwest-control.com
18 DP & DM Are Not Manufactured by Conrader
DRAIN COCK with PULL CORD DP & DM SERIES
• Applications: Industrial and Automotive
• Brass Stem Tilts to Open the Valve at Minimum Pull Cord Force Stainless Steel Spring Returns the Stem to Positively Seal Against the Nitrile O-Ring when Force on the Cord is Release
• Construction: Brass Body, Washer and Stem
• Maximum Pressure: 200 PSI
• Maximum Temperature: 200˚F
• Everseal 483 Sealant Standard (MCDP)
Part No. Cable Length
DP25 60”
DM25 36”
An Air Operated Automatic Tank Drain Valve. It Removes System Condensation When Actuated at the Load and Unload Pressures.
Smart Start Eliminates Compressor Starting Problems, It Automatically Allows the Compressor Motor to Reach Full Speed Prior to Running Under Loaded Conditions The Smart Start Accomplishes a Loadless Start by Controlling the Compressor Inlet. Simply Replace the Standard Inlet Filter on the Compressor with the Smart Start and Starting Problems Disappear Benefits
• Smart Start Reduces Amperage Draw During Start Up and Eliminates Tripped Circuit Breakers
• Compensates for Starting Voltage Drops and Allows the Use of Multiple Tools on the Same Circuit
• Worry Free Operation Cold Weather and Extension Cords Won’t Stop Compressor from Starting. Eliminates the Need for Unloaders that Blow System Air to Atmosphere and Increase Pump Up Time
A Shuttle Control Valve Designed for Applications Where it is Necessary to Control One Device From Two Sources
• Features a Positive Sealing Piston, Brass Body Construction
• 500 PSI Maximum Working Pressure
• Maximum Operating Temp: 250ºF
SHUTTLE CONTROL VALVE SCV
SMART START®
Part No. Inlet Size (In)
Flow (SCFM)
AIC38 3/8
AIC50 1/2 15
Inlet 1/4 Female
Outlet 1/4 Compression
Inlet 1/4 Male
951 Old Rand Rd Suite 116 Wauconda IL 60084
P 847-487-5599 F 847-487-0909
www.midwest-control.com
THROTTLE CONTROLS & ACCESSORIES Applications: Used on Gas Engine Driven Compressors to Reduce Engine Speed to Idle. When the Continuous Run Control Pilot (Pilot Unloader Valve or Pilot Valve) has Reached It's Cut Out Setting It Saves Fuel and Reduces Engine and Compressor Wear. The 1/8” Male Inlet is Connected to the Throttle Control Port of the Vent Unloader or Connected to a “Tee” Off the Head Unloader Line for Pilot Valve Installations. The Cable is Attached to the Appropriate Throttle Linkage on the Engine. The Cable Housing Should be Anchored Using the Supplied Cable Clamps. During Operation the Vent Unloader or Pilot Valve Sends a Pressure Signal to the Throttle Control at the Cut Out Setting, Causing the Throttle Control Piston to Extend the Control Cable which Pushes the Throttle Lever, Causing the Engine to Idle Down. At the Cut In Setting the Pressure Signal Going to the Throttle Control is Vented, Allowing the Spring to Return the Piston Cable and Throttle Lever to the Original Full Speed Position.
• Construction: Brass Body and Piston, Stainless Steel Wire, Corrosion Resistant Molybdenum Filled Nylon Casing, Viton O Ring Seal
• Maximum Pressure: 500 PSI
• Minimum Pressure: 40 PSI
• Maximum Temperature: Operating Mechanism 450˚F
• Everseal 483 Sealant Standard BWTCP, and BWTCLP
• Available Lengths: 12”, 18”, 24”, 30”, 36”, 48”,60” Custom Lengths Available Consult Midwest Control
• Standard HP Range: BWTCP 2 - 8HP, “BWTCLP” Heavy Duty Series 8HP & Higher
• BWTCP & BWTCLP Series Includes Cable Clamp with Locking Tab for Installation on Engine Shroud and Threaded Setting Clamp for Installation on Throttle Plate
20
BWTCP
BWTCLP
Swivel Clamp Briggs/Honda C Style Clamp
Cable Clamp with Locking Tab Threaded Casing Clamp Honda Bushing
THROTTLE CONTROL ACCESSORIES
Part No. Length (In.)
Part No. Length (In.)
BWTCP 1/8” PILOT CONNECTION FOR SYSTEMS WITH EXTERNAL
UNLOADERS (For Compressors with External Unload-ing Devices and Engines Up to 8 Hp)
BWTCLP 1/8” PILOT CONNECTION FOR SYSTEMS WITH EXTERNAL UNLOADERS
(For Compressors with External Unloading Devices and Engines 8 Hp and Above)
BWTCP12-0817 12 BWTCLP12-0817 12
BWTCP18-0817 18 BWTCLP18-0817 18
BWTCP24-0817 24 BWTCLP24-0817 24
BWTCP30-0817 30 BWTCLP30-0817 30
BWTCP36-0817 36 BWTCLPC36-0817 36
BWTCP48-0817 48 BWTCLP48-0817 48
BWTCP60-0817 60 BWTCLP60-0817 60
BWTCSP-H-5565-B
Part No. Length (In.)
BWTCSP 1/4” TUBE CONNECTION “AIRLINE STYLE” INCLUDES MOUNTING HARDWARE