Top Banner
- 1 - Configuring a RAID Set (TRX40 Series) RAID Levels..................................................................................................................... 2 1-1 Configuring SATA Controllers .................................................................................... 2 A. Installing SATA hard drive(s) in your computer ....................................................... 2 B. Configuring SATA controller mode in BIOS Setup .................................................. 3 C. UEFI RAID Configuration ....................................................................................... 3 1-2 Installing the SATA RAID/AHCI Driver and Operating System .................................. 7 A. Installing Windows ................................................................................................. 7 B. Rebuilding an Array ................................................................................................ 8
8

Configuring a RAID Set (TRX40 Series) · 2019-12-03 · - 5 - Step 4: On the Select Physical Disks screen, select the hard drives to be included in the RAID array and set them to

Feb 13, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Configuring a RAID Set (TRX40 Series) · 2019-12-03 · - 5 - Step 4: On the Select Physical Disks screen, select the hard drives to be included in the RAID array and set them to

- 1 -

Configuring a RAID Set (TRX40 Series)

RAID Levels .....................................................................................................................21-1ConfiguringSATAControllers ....................................................................................2

A.InstallingSATAharddrive(s)inyourcomputer ....................................................... 2B.ConfiguringSATAcontrollermodeinBIOSSetup .................................................. 3C.UEFIRAIDConfiguration ....................................................................................... 3

1-2InstallingtheSATARAID/AHCIDriverandOperatingSystem ..................................7A.InstallingWindows ................................................................................................. 7B.RebuildinganArray ................................................................................................ 8

Page 2: Configuring a RAID Set (TRX40 Series) · 2019-12-03 · - 5 - Step 4: On the Select Physical Disks screen, select the hard drives to be included in the RAID array and set them to

- 2 -

To configure SATA hard drive(s), follow the steps below:A. Installharddrive(s)inyourcomputer.B. ConfigureSATAcontrollermodeinBIOSSetup.C. ConfigureaRAIDarrayinRAIDBIOS(Note1)D. InstalltheSATARAID/AHCIdriverandoperatingsystem

Before you begin • AtleasttwoSATAharddrivesorSSDs(Note2)(toensureoptimalperformance,itisrecommendedthatyou

usetwoharddriveswithidenticalmodelandcapacity).(Note3) • AWindowssetupdisk. • Motherboarddriverdisk. • AUSBthumbdrive.

1-1 Configuring SATA Controllers

A. Installing SATA hard drive(s) in your computerInstall the hard drives/SSDs in theSATA/M.2 connectors on themotherboard.Then connect the powerconnectorsfromyourpowersupplytotheharddrives.

RAID LevelsRAID 0 RAID 1 RAID 10

MinimumNumberofHardDrives ≥2 2 4

ArrayCapacity Numberofharddrives*Sizeofthesmallestdrive

Sizeofthesmallestdrive (Numberofharddrives/2)*Sizeofthesmallestdrive

FaultTolerance No Yes Yes

(Note1) SkipthisstepifyoudonotwanttocreateRAIDarrayontheSATAcontroller.(Note2) AnM.2PCIeSSDcannotbeusedtosetupaRAIDseteitherwithanM.2SATASSDoraSATAharddrive.(Note3) Referto"InternalConnectors,"fortheinstallationnoticesfortheM.2,andSATAconnectors.

Page 3: Configuring a RAID Set (TRX40 Series) · 2019-12-03 · - 5 - Step 4: On the Select Physical Disks screen, select the hard drives to be included in the RAID array and set them to

- 3 -

TheBIOSSetupmenusdescribedinthissectionmaydifferfromtheexactsettingsforyourmotherboard.TheactualBIOSSetupmenuoptionsyouwillseeshalldependonthemotherboardyouhaveandtheBIOSversion.

B. Configuring SATA controller mode in BIOS SetupMakesuretoconfiguretheSATAcontrollermodecorrectlyinsystemBIOSSetup.Step:Turnonyourcomputerandpress<Delete>toenterBIOSSetupduringthePOST(Power-OnSelf-Test).UnderSettings\IO Ports, setSATA Configuration\SATA ModetoRAID(Figure1).Thensavethesettingsandrestartyourcomputer.(IfyouwanttouseNVMePCIeSSDstoconfigureRAID,makesuretosetNVMe RAID modetoEnabled. Then set how the bandwidth of the PCIe slot you use is divided. Save the changes and exit BIOS Setup. )

C. UEFI RAID ConfigurationStep1:InBIOSSetup,gotoBoot andsetCSM SupporttoDisabled(Figure2).SavethechangesandexitBIOSSetup.

Figure1

Figure2

Page 4: Configuring a RAID Set (TRX40 Series) · 2019-12-03 · - 5 - Step 4: On the Select Physical Disks screen, select the hard drives to be included in the RAID array and set them to

- 4 -

Step2:Afterthesystemreboot,enterBIOSSetupagain.ThenentertheSettings\IO Ports\RAIDXpert2 Configuration Utility sub-menu(Figure3).

Step3:OntheRAIDXpert2ConfigurationUtilityscreen,press<Enter>onArray Management toenter theCreate Arrayscreen.Then,selectaRAIDlevel(Figure4).RAIDlevelssupportedincludeRAID0,RAID1,andRAID10(theselectionsavailabledependonthenumberoftheharddrivesbeinginstalled).Next,press<Enter>onSelect Physical DiskstoentertheSelect Physical Disksscreen.

Figure3

Figure4

Page 5: Configuring a RAID Set (TRX40 Series) · 2019-12-03 · - 5 - Step 4: On the Select Physical Disks screen, select the hard drives to be included in the RAID array and set them to

- 5 -

Step4:OntheSelect Physical Disksscreen,selecttheharddrivestobeincludedintheRAIDarrayandsetthemtoEnabled.Next,usethedownarrowkeytomovetoApply Changesandpress<Enter>(Figure5).ThenreturntothepreviousscreenandsettheArray Size,Array Size Unit,Read Cache PolicyandWrite Cache Policy.

Step5:Aftersettingthecapacity,movetoCreate Arrayandpress<Enter>tobegin.(Figure6)

Figure5

Figure6

Page 6: Configuring a RAID Set (TRX40 Series) · 2019-12-03 · - 5 - Step 4: On the Select Physical Disks screen, select the hard drives to be included in the RAID array and set them to

-6-

Aftercompleting,you'llbebroughtbacktotheArray Managementscreen.UnderManage Array Properties youcanseethenewRAIDvolumeandinformationonRAIDlevel,arrayname,arraycapacity,etc.(Figure7)

Delete RAID VolumeTo delete aRAID array, select the array to be deleted on theRAIDXpert2 Configuration Utility\Array Management\Delete Array screen.Press<Enter>onDelete Array to enter theDelete screen.Then setConfirm toEnabledandpress<Enter>onYes(Figure8).

Figure7

Figure8

Page 7: Configuring a RAID Set (TRX40 Series) · 2019-12-03 · - 5 - Step 4: On the Select Physical Disks screen, select the hard drives to be included in the RAID array and set them to

- 7 -

1-2 Installing the SATA RAID/AHCI Driver and Operating SystemWiththecorrectBIOSsettings,youarereadytoinstalltheoperatingsystem.

A. Installing Windows AssomeoperatingsystemsalreadyincludeSATARAID/AHCIdriver,youdonotneedtoinstallseparateRAID/AHCIdriverduringtheWindowsinstallationprocess.Aftertheoperatingsystemisinstalled,werecommendthatyouinstallallrequireddriversfromthemotherboarddriverdiskusing"XpressInstall"toensuresystemperformanceandcompatibility.IftheoperatingsystemtobeinstalledrequiresthatyouprovideadditionalSATARAID/AHCIdriverduringtheOSinstallationprocess,pleaserefertothestepsbelow:

Step1:CopytheHw10 folderunderthe\BootDrvfolderinthedriverdisktoyourUSBthumbdrive.

Step2:BootfromtheWindowssetupdiskandperformstandardOSinstallationsteps.Whenthescreenrequestingyoutoloadthedriverappears,selectBrowse.

Step3:InserttheUSBthumbdriveandthenbrowsetothelocationofthedriver.Thelocationofthedriverisasfollows:Windows64-bit:\Hw10\RAID\x64

Step4:WhenascreenasshowninFigure1appears,selectAMD-RAID Bottom DevicefirstandclickNexttoloadthedriver.ThenselectAMD-RAID ControllerandclickNexttoloadthedriver.Finally,continuetheOSinstallation.

Figure1

Page 8: Configuring a RAID Set (TRX40 Series) · 2019-12-03 · - 5 - Step 4: On the Select Physical Disks screen, select the hard drives to be included in the RAID array and set them to

- 8 -

B. Rebuilding an ArrayRebuildingistheprocessofrestoringdatatoaharddrivefromotherdrivesinthearray.Rebuildingappliesonlytofault-tolerantarrayssuchasRAID1andRAID10arrays.Toreplacetheolddrive,makesuretouseanewdriveofequalorgreatercapacity.TheproceduresbelowassumeanewdriveisaddedtoreplaceafaileddrivetorebuildaRAID1array.

Whileintheoperatingsystem,makesuretheChipsetandRAIDdrivershavebeeninstalledfromthemotherboarddriverdisk.Thendouble-clicktheRAIDXpert2icononthedesktoptolaunchtheRAIDutility.

Step1:EntertheloginIDandpassword(default:"admin"),andthenclickSubmittolaunchAMD RAIDXpert2.

Step2:In theDisk Devices section, left-clickyourmousetwiceonthenewly-addedharddrive.

Step3:Onthenextscreen,selectAssign as Global Spare andclickConfirm.

Step4:Duringtherebuildprocess,youcanselectthearraythat is being built (displayed in red) in theActive Volumessectiontocheckthecurrentprogress.

Step5:Then rebuild is complete when theTask State columnshows"COMPLETED."