Top Banner
1 WELCOME TO THE WONDERFUL WORLD OF PIPING COMPRESSORS Valdel Engineers and Constructors, Ltd. BY: SAMI UR REHMAN PIPING DEPARTMENT
53

Compressors

Nov 09, 2014

Download

Documents

SAMI UR RAHMAN

SAMI UR RAHMAN
PRINCIPAL ENGINEER PIPING DEPARTMENT
VALDEL ENGINEERS AND CONSTRUCTORS
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Compressors

1

WELCOME TO THE WONDERFULWORLD OF

PIPING

COMPRESSORS

Valdel Engineers and Constructors, Ltd.

BY: SAMI UR REHMAN

PIPING DEPARTMENT

Page 2: Compressors

2

INTRODUCTION OF COMPRESSOR

Compressors are machines which are used to increase the pressure of a gas by mechanically reducing its volume with in its casing.

Closely related to the pumps. Pressure and temperature will increase. Gases are compressible fluid. Process, Chemical reactions that takes place at elevated pressure. Transportation or transmission of gases through pipelines.

Page 3: Compressors

3

CLASSIFICATION OF COMPRESSORS

Compressors can be further classified on its working principle Positive displacement compressors. Dynamic compressors.

Page 4: Compressors

4

Reciprocating Compressors Reciprocating compressors are machine in which The compressing

element is a piston following a reciprocating (linear) motion in a cylinder.

Temperature is increase due to increase kinetic energy of the molecules.

Generally used for small to medium volume and compress gas to extremely high pressure.

Piston

Page 5: Compressors

5

Two Stage Horizontal Reciprocating Compressor

MOTOR

Page 6: Compressors

6

Three stage Reciprocating Compressor

Lines Size1 Stage 24”to 18”2 Stage 18”to 12”3 Stage 12”to 10”

Page 7: Compressors

7

Compressor DriverGenerally Electrical motors are used for reciprocating compressors these are of two types Synchronous and Induction motor.

Synchronous motor is exactly same as that of rotating magnetic field they are used for higher power and lower RPM.Efficiency of synchronous motor is 94-97 and is better than induction motor.

Electric Motor

Page 8: Compressors

8

Auxiliary Equipment It is supplied by compressor vendor as a skid mounted package with

equipments, its internal piping arrangements, controls and instruments. Generally skid consists of these two systems.

Lubrication system Cooling system

Lubrication System Lubrication is lifeline of any rotating machinery. the lube oil system

Contains reservoir, a pair of circulation pump, shell tube coolers and a duplex filter arrangement . The main function of the lubrication are

Minimize friction and to avoid contact between moving parts. Remove heat induced by friction Protect metal from corrosion.

Page 9: Compressors

9

Lube oil consolemaintenance

Lube Oil Console

Page 10: Compressors

10

Auxiliary Equipment

Lube Oil Skid

Page 11: Compressors

11

Use of Lubrication Generally, two oil pumps are provided for lubrication, one

driven by crankshaft is known as main oil pump (MOP) and other driven by separate elective motor is called auxiliary oil pump (AOP).

Page 12: Compressors

12

Cooling System

Heat is generated due to compression of the gas friction in the cylinder . The need to provide cooling can be performed with Air Water (open and close water cooling)

Its difficult to control these limits in open system the PH value range of 6.5 to 8.Hardness should be less than 200 ppm.Suspended solids less than 100 ppm.

Its very easy to add additives in close circulationWater- glycol solution which has low freezing point and high boiling point with respect to water use in close circulation.

Page 13: Compressors

13

Accessories

Suction Separator Because compressors requires dry gas free of foreign particles,

the inlet gas is passed through suction drum. Its function is to remove oil and condensates from the gas, the principles of operation are Gravity, Impingement, Centrifugal force and Filtration

Pulsation Dampener or Volume Bottle Volume bottles accumulate sufficient volume(5-20 times of

cylinder) of gas to render uniform flow of gas. Pulsation dampers are devices with the internal system capable of

cutting off certain frequencies. The Pulsation dampers must be installed as close to the cylinder as

possible to avoid the possibilities of acoustic resonance between cylinder and device.

Page 14: Compressors

14

Suction Separator

Page 15: Compressors

15

Pulsation Dampener or Volume Bottle

Page 16: Compressors

16

Location and Maintenance

When locating compressors, consideration must be given to Operability Safety Maintenance

RECIPROCATING COMPRESSORS Reciprocating compressors must be mounted close to grade.

Because of the extreme vibration in the piping system.

Compressor foundation elevation depends on these steps

Page 17: Compressors

17

Setting Elevations of Reciprocating Compressors

3.Minimum Distance Required to enter the header

Nozzle

Page 18: Compressors

18

Proper Access To Valves

Well Ventilated

Page 19: Compressors

19

Reciprocating Compressors Arrangement

At Least Two Stairways

Page 20: Compressors

20

Reciprocating Compressors Arrangement

Well Ventilated To Prevent Gas Build Up

From Leaks

Page 21: Compressors

21

Open Installation And Enclosed Structure

Page 22: Compressors

22

Planning For Cylinder Removal

Page 23: Compressors

23

Reciprocating Compressors Piping

Page 24: Compressors

24

Reciprocating Compressor Piping

Allowable nozzle load Eccentric Reducer with the flat side on the bottom of the pipe to

prevent the accumulation of any liquids Isolation valve with spectacle blind shall be provided in the inlet

and outlet piping Temporary strainers must be used in inlet. Branch connecting shall be minimized or located at near to the

point where the header is anchored. Piping shall be routed as close to grade or to heavy concrete

foundation as possible. Positive displacement machinery shall be equipped with a PRV. Pressure measurement connection complete with isolation valves

shall be provided on the inlet and outlet piping.

Page 25: Compressors

25

Reciprocating Compressors Typical Piping

Page 26: Compressors

26

Reciprocating Compressor With all

Components

Compressors linebranch

Page 27: Compressors

27

Reciprocating Compressor Support

Pipe support must be given special consideration due to the pulsation.

Rigid anchors, to provide lateral stiffness needed to restrain dynamic force

Compressor piping should never be supported from shelter steel work or operating floor.

And must be provided with independent foundation to avoid transmission of vibrations.

Page 28: Compressors

28

Reciprocating Compressor Support

Page 29: Compressors

29

Centrifugal Compressor Dynamic type compressor are machine in which air or gas is

compressed by the dynamic action of rotating vanes or impeller. Centrifugal compressors are used to handle large volume of gas

to moderating high pressure. Gas enters the machines at the axis of high speed impeller and

discharges radially into a peripheral chamber at high pressure. Centrifugal compressors may have horizontally split or vertically

split casing .

Page 30: Compressors

30

Horizontal Split Case Compressor

Vertical Split Case Compressor

Page 31: Compressors

31

Centrifugal Compressor

Page 32: Compressors

32

Centrifugal Compressor With Lube Oil Console

Lube Oil Console

Centrifugal Compressor

Page 33: Compressors

33

COMPRESSOR DRIVES

Electrical motor Steam turbine Gas turbine

Steam Turbine Back Pressure turbines are driven by high pressure steam and do

not require surface condenser. Condensing turbines are usually driven by low pressure steam.

Gas TurbineUsually employed in remote area, where gas is available for fuel.

Page 34: Compressors

34

Elevation for Centrifugal Compressors

Page 35: Compressors

35

Page 36: Compressors

36

Page 37: Compressors

37

Auxiliary Equipment For Centrifugal CompressorsAir filtersWaste heat systemLube oil seal oil consoleSurface condensersCondensate pumps

Maintenance & Location of Centrifugal Compressors The oil console is located closely at the turbine end to facilitate a free draining lube oil return to the reservoir . Control panel is located On the operating floor at the driver end The size of the operating floor must be established by allowing clearance of 6 ft all around machine. An access road is required for mobile handling equipment.

Page 38: Compressors

38

Grade Mounted Centrifugal Compressor Open-Sided Structure

Page 39: Compressors

39

Grade Mounted or Elevated Centrifugal Compressor Open-Sided Structure

Page 40: Compressors

40

Grade Mounted Compressor Wall Shelter

Page 41: Compressors

41

Elevated Centrifugal Compressor No Shelter

Page 42: Compressors

42

Vertical Condensate

Pump

Inlet Air Filter

Gas turbines require large amounts of clean filtered air for operation

Removes the condensate from the hot well in the surface condenser

Page 43: Compressors

43

Seal Oil Console

Surface Condenser

Reduce gas or vapor to a liquid by removing heat

Page 44: Compressors

44

Waste Heat System

Hot exhaust gas from gas turbines may be used to generate steam or heating the oil and may be used as a heating

medium

Page 45: Compressors

45

The operating floor elevation is next established by making the required headroom allowance beneath horizontal pipe run under the floor while allowing the lube oil return header to slope down To its connecting point on the reservoir. The major factor in setting the elevation of the minimum height that satisfy NPSH requirements of the condensate extraction pumps. The straight run requirements of the suction line its could be varies between 3D to 8D.

ELEVATION OF COMPRESSORS

Page 46: Compressors

46

Surface Condenser Elevation

Page 47: Compressors

47

Elevated Compressor

Page 48: Compressors

48

CENTRIFUGAL COMPRESSORS PIPING & SUPPORT

Nozzle allowable loads.Straight run requirements 3D to 8DSuction and discharge piping on bottom entry installations should Preferably be run close to grade.Do not support compressor piping from the compressor foundation structure .Strainer must be installed.All Valves must be accessible ,preferable from grade.Additional flanges for maintenance.Alignment is more easily achieves if adequate field fit up welds are allowed in spools

Page 49: Compressors

49

Centrifugal Compressor Inlet & Outlet Nozzles

Lines SizeInlet 84”outlet 42”

Inlet LineOutlet line

Page 50: Compressors

50

Straight run requirements

Page 51: Compressors

51

Strainer Must Be Installed.

Additional Flanges For Maintenance

Page 52: Compressors

52

Valves Must Be Accessible

Page 53: Compressors

53

QUESTION ??