Top Banner
Mounting Instructions Completion Concealed Box
16

Completion Concealed Box...1 T ECHNI ALF URS Pressure range min/max 0,5/5 bar (in case of water pressure highter than 5 bar weeracommend installing pressure reducers). Recommended

Mar 19, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Completion Concealed Box...1 T ECHNI ALF URS Pressure range min/max 0,5/5 bar (in case of water pressure highter than 5 bar weeracommend installing pressure reducers). Recommended

Mounting Instructions

Completion Concealed Box

Page 2: Completion Concealed Box...1 T ECHNI ALF URS Pressure range min/max 0,5/5 bar (in case of water pressure highter than 5 bar weeracommend installing pressure reducers). Recommended

1 TECHNICAL FEATURES

Pressure range min/max 0,5/5 bar

(in case of water pressure highter than 5 bar weeracommend installing pressure

reducers).

Recommended pressure 3 bar.

Operation:

Either with gas or electric accumulation

boilers.

Centralised systems.

Safety lock at: 41°

Min. Working temperature: 3°C

Min. recommended: 15°C

Max. Working temperature: 80°C

Max. recommended:65°C

Recommended thermal differential 50°C

Safety system with flow stop in case

of lack of one of the two waters.

Warning: contact the plumber for the choice of the best water heating device.

Page 3: Completion Concealed Box...1 T ECHNI ALF URS Pressure range min/max 0,5/5 bar (in case of water pressure highter than 5 bar weeracommend installing pressure reducers). Recommended

2

FLOW RATE ( L/min ) Press.

9,2

13,2

18,7

22,9

26,4

29,5

bar

0,5

1

2

3

4

5

Term. 2 ways

Exit 1/2/3

8,2

11,7

16,7

20,7

24

26,6

Term. 1 way

Exit 2

8,2

11,7

16,4

20

23

25,8

Exit 3 Mix

8,2

11,7

16,4

20

23

25,8

Term. 2 way

Page 4: Completion Concealed Box...1 T ECHNI ALF URS Pressure range min/max 0,5/5 bar (in case of water pressure highter than 5 bar weeracommend installing pressure reducers). Recommended

3

FLOW RATE ( L/min )

Exit 1

Press.

9,4

13,4

19,2

23,7

27,4

30,5

bar

0,5

1

2

3

4

5

Exit 2

8,1

11,6

16,6

20,5

23,8

26,6

Exit 3

8,1

11,6

16,6

20,5

23,8

26,6

Term. 3 ways

Page 5: Completion Concealed Box...1 T ECHNI ALF URS Pressure range min/max 0,5/5 bar (in case of water pressure highter than 5 bar weeracommend installing pressure reducers). Recommended

4 PRE- INSTALLATION INFORMATIONS

Page 6: Completion Concealed Box...1 T ECHNI ALF URS Pressure range min/max 0,5/5 bar (in case of water pressure highter than 5 bar weeracommend installing pressure reducers). Recommended

5

GB Mounting instructions

topalto

hoch haut

PACKAGE CONTENT

THERMOSTATIC 1-2-3WAYS

Page 7: Completion Concealed Box...1 T ECHNI ALF URS Pressure range min/max 0,5/5 bar (in case of water pressure highter than 5 bar weeracommend installing pressure reducers). Recommended

6

GB Mounting instructions

topalto

hoch haut

PACKAGE CONTENT

THERMOSTATIC 1-2-3WAYS

Page 8: Completion Concealed Box...1 T ECHNI ALF URS Pressure range min/max 0,5/5 bar (in case of water pressure highter than 5 bar weeracommend installing pressure reducers). Recommended

7

OK

INSTALLATION

1

2

Page 9: Completion Concealed Box...1 T ECHNI ALF URS Pressure range min/max 0,5/5 bar (in case of water pressure highter than 5 bar weeracommend installing pressure reducers). Recommended

8

OK

3

Hot HotCold Cold

8

4

Page 10: Completion Concealed Box...1 T ECHNI ALF URS Pressure range min/max 0,5/5 bar (in case of water pressure highter than 5 bar weeracommend installing pressure reducers). Recommended

9

topalto

hochhaut

6

top alto

hoch haut

0 ÷ 11 mm

11 ÷ 26 mm 5

Page 11: Completion Concealed Box...1 T ECHNI ALF URS Pressure range min/max 0,5/5 bar (in case of water pressure highter than 5 bar weeracommend installing pressure reducers). Recommended

10

3

7A

3

7B

Page 12: Completion Concealed Box...1 T ECHNI ALF URS Pressure range min/max 0,5/5 bar (in case of water pressure highter than 5 bar weeracommend installing pressure reducers). Recommended

11

3

3

8A

3

8B

Page 13: Completion Concealed Box...1 T ECHNI ALF URS Pressure range min/max 0,5/5 bar (in case of water pressure highter than 5 bar weeracommend installing pressure reducers). Recommended

12 MAINTENANCE

topalto

hochhaut

8

3

1

2

Page 14: Completion Concealed Box...1 T ECHNI ALF URS Pressure range min/max 0,5/5 bar (in case of water pressure highter than 5 bar weeracommend installing pressure reducers). Recommended

13 MAINTENANCE

topalto

hochhaut

8

3

2

1

Page 15: Completion Concealed Box...1 T ECHNI ALF URS Pressure range min/max 0,5/5 bar (in case of water pressure highter than 5 bar weeracommend installing pressure reducers). Recommended

14 USER’S GUIDE

Stop 90°

Stop 90° 90°

60°

60°

Stop

60°

Stop

60°Stop

60°

THERMOSTATIC 1WAY

MIX

THERMOSTATIC 3WAYS

THERMOSTATIC 2WAYS

Page 16: Completion Concealed Box...1 T ECHNI ALF URS Pressure range min/max 0,5/5 bar (in case of water pressure highter than 5 bar weeracommend installing pressure reducers). Recommended

C0

83

196.0

0000Z

Z R

ev. 0