8. Characteristics (If the characteristics of appearance has only one characteristic, it can be
omitted.)
7. Installation methods (If select the standard installation method, it can be omitted.)
6. Accuracy Class (If has only one possible accuracy class, it can be omitted.)
5.Auxiliary Power
4.Operating Voltage and Current
3.Overload (The regular instrument is 1 and 2 times, and it can make 1.2 , 2, 3, 5 or
6 times etc.)
2.Specification (measuring range.)
1.Product model
Operating Frequency: 50Hz, 60Hz or 400Hz; Marine meter mark: SC; Meet ULrequirements: UL;Other functions: RS-485 Serial Port, 4-20mA output, 1 max contact + 1 min contact meters with relay;Display (Digital Meter): 3 digits, 31/2 digits, 4 digits, 41/2 digits. Special label (Net Insulation Monitor): A or B;Response time (Maximum Demand Indicator): 8min, 15min;Working method (Maximum Demand Indicator): direct heat type or indirect heat type.
Notice: the product encoding should be written according to the formation. When clients place the order, choose to fill according to the selection of
formation content of every form. According to the compiling order of contents from 1-9, if there are some items that are not necessary to fill, they can be
omitted during the type-compiling period.
Indicating Angle
Indicating Angle
Product Certificate
AC VoltmeterAC Voltmeter with
Rectifier
AC Voltmeter with Rectifier
Power meter - Wattmeter
Phase Sequence Indicator
AC Ammeter with Rectifier
AC Voltmeter with Rectifier
Product Certificate100mA~60A, Connecting to CT : X/1A,X/5A
100mA~20A, Connecting to CT :X/1A,X/5A
100uA~60A, With external shunt:X/75mV,X/60mV
100uA~60A, With external shunt:X/75mV,X/60mV
10V~600V, Connecting to PT: X/100V,X/110V
10V~600V, Connecting to PT: X/100V,X/110V
100mA~60A, Connecting to CT:X/1A,X/5A
100mA~20A, Connecting to CT:X/1A,X/5A
100uA~60A, With shunt:X/75mV,X/60mV
100uA~60A, With shunt:X/75mV,X/60mV
10V~600V, Connecting to PT:X/100V,X/110V
10V~600V, Connecting to PT:X/100V,X/110V
New Products
01
02
16
19
21
30
KLY-3432C
Power & Energy Meter Meters with Auxiliary Lighting Switch Position Indicator
Page 01
Rectangular Type Meter Moun ting ( Rectangular Type) DIN Rail Type Meter
Square-Round MeterRectangular-Round Meter
AC Ammeter/Voltmeter With Selector Switch
AC Ammeter/Voltmeter(Moving Iron Movement)
Square Type Meter
AC Ammeter/Voltmeter with Rectifier
(Moving Coil Movement)
(Moving Coil Movement)DC Ammeter/Voltmeter
Double Meter Pointer Frequency Meter Reed Frequency Meter Ammeter / Voltmeter with Alarm
Maximum Demand Indicator Synchroscope Pointer Synchroscope Hours Run Meter
Net Insulation Monitor Phase Sequence Indicator Power Factor Meter Active Power Meter ( W)
Reactive Power Meter (Var) Power & Energy Meter Explosion-proof Meter
Non-electric Units Indicator 0V Voltmeter
Rated Value Voltmeter
Mounting(Square Meter )
Product Details Mounting
Digital Meter, Connection Diagram
Digital Parameter Meter Digital Intelligence Parameter Meter
Digital Intelligence Parameter Meter
Connection Diagram
Current Transformer
Installation Methods KLY-M Series CT KLY-M Series CT
Measuring and indicating the active power/ electrical energy.
Meas. Voltage: AC100V,220V,380V,440V;
Meas. Current: 1A,5A;
Rated frequency: 50Hz, 60Hz;
Measurement scope: same as KLY-W96.
KLY-SP25R
KLY-SP25S
KLY-SP32R
KLY-SP36S
KLY-SP25R-1
KLY-SP25S-1
KLY-SP32R-1
KLY-SP36S-1
25 25
32
25
36 36
25 25
32
25
36 36
AC 24~36V
48~60V
100~127V
220V~230V
DC 24~36V
48~60V
100~127V
220V~230V
KLY-SP25R KLY-SP32R KLY-SP25S KLY-SP36S5
130
20.5
0.3
Max.10
Rudder Angle Meter /Tachometer (KLY-C4124 series)
Dimension Drawing
Power & Energy Meter
Meters with Auxiliary Lighting
Switch Position IndicatorSwitch posit ion indicator is used for remote indication of contact posit ions at power plants and
switching stations.
Can also be used advantageo usly as an indicator in mimic diagrams. The symbol letter is SP.
Display
Off , On , Error or Isabled .
Picture Product Structure & Technical Symbol
OnOff ErrorType Specification
Characteristics
Front ShapeFront Dimension (mm)Others
Dimension Drawing
Picture Product StructureTechnical Symbol
Type Specification
AC Ammeter
Moving Iron Movement
Moving Coil Movement
AC Ammeterwith Rectifier
Pushing tight type
Pushing tight type
Pushing tight type
Pushing tight type
Pushing tight type
Pushing tight type
Pushing tight type
Pushing tight type
Pushing tight type
Overload Accuracy
Class
Characteristics
AppearanceInstruction
AngleOthers
1 or 2 timesCustomized: 3, 5, 6 times
50Hz,
60Hz,
400Hz
(SC)
U L Certificated:
(UL)
Operating frequency:
Marine type:
Square
Round
Square
Round
Square
Round
Square
Round
Connection
diagram
(page29)
Utilize the 250 moving coil core. Take advantage of long duration LED lighting. The brightness can be adjusted. Large calibrated scale, and it is easy to read. Principal parameters and technical index:Measuring range:Voltage (DC): minimum: 0 1V or -1 0 1V; maximum: 0 100V or -100 0 100V.Current (DC): minimum: 0 1mA or -1 0 1mA; maximum: 0 100mA or -100 0 100mA, 4-20mA. Lighting power supply: AC 110V/220V 20% 50/60Hz, power dissipation:5VA; AC 24V 20%,DC 24V 25% ,power dissipation:5VA.
In order to read the indicating values in darkness, Complee provides Meters with lighting functions.
The meters is mainly installed in the wing bridge of shipping cab. They are used to indicate changingspeed and rudder angle etc. They are water-proof, guard against salt fog, and are suita ble for th e ocean environment.
1 or 2 timesCustomized: 3, 5, 6 times
1 or 2 timesCustomized: 3, 5, 6 times
1 or 2 timesCustomized: 3, 5, 6 times
1 or 2 timesCustomized: 3, 5, 6 times
1 or 2 timesCustomized: 3, 5, 6 times
StandardMounting
>
>
>
Moving Coil Movement
AC Ammeterwith Rectifier
AC Ammeterwith Rectifier
AC Ammeterwith Rectifier
AC Voltmeterwith Rectifier
Moving Coil Movement
AC Voltmeterwith Rectifier
Connectingto PT:
Connectingto CT:
Connectingto CT:
Connectingto CT:
Connectingto CT:
Connecting to CT:
Connecting to CT:
Ordering note: specify the Aux.power and the symbol letters are YG.
AC Ammeter and Voltmeter with Selector SwitchA selector switch is built into the instrument for measurement of AC current or voltage in a three phase network. The symbol letter is Z.
AC Voltmeter with Selector Switch
3- Position (3P3W): L1-L2 L1-L3 L2-L3 (Additional OFF position is available on request) 6- Position (3P4W): L1-L2 L1-L3 L2-L3 L1-N L2-N L3-N (Additional OFF position is available on request)
AC Ammeter with Selector SwitchAC Ammeter with 3-Posit ion selector switch can be used for the measurement of AC current in three phase system. OFF position is available on request.
Note: DC Ammeter/Voltmeter with selector switch can be produced on request.
Dimension drawing see figure 3 on page 15
PictureProduct StructureTechnical Symbol
Type SpecificationCharacteristics
AppearanceOthersAccuracy
ClassStandardMounting
StandardMounting
AC Voltmeterwith
selector switch
6-Position
AC Voltmeterwith
selector switch
3-Position
AC Ammeterwith
selector switch
3-Position
Double MeterDouble Meter can be used for the independent measurement of two parameters. These instruments save both space and assembly t ime. And they are ideal component in plant.
Note: Double Meter for measuring voltage and frequency simultaneously or for measuring current and voltage simultaneously can be customized.
The accuracy for Square Type (KLY/CP-F48), Square-round Type (KLY-F50,60,80), Rectangular-round Type (KLY-F560, 670,780, 8100), Rectangular Type (KLY-9681, 9682) is class 1.0 and the other types are class 0.5.
Picture Type SpecificationCharacteristics
Others
Product StructureTechnical Symbol
StandardMounting
AccuracyClass
Pushing tight type
Pushing tight type
Pushing tight type
Two pointers
per-pendicular
Frequency Meter
Moving Coil Movement
DoubleFrequency
Meter
Moving Coil Movement
250
Reed Frequency Meter
Frequency meter wit h one row of horizontal reed is used to measure the frequency of the electrical net ranging from 45Hz to 65Hz. Vertical arrangement is available on request. The symbol letter is R.
Frequency meter with two rows of horizontal reeds are used to compare two frequencies for synchronizing with two electrically separated systems. Vertical arrangement is available on request. The symbol letter is 2R.
Note: Voltage Fluctuation Allowance: 20%.
Picture Type SpecificationWork
VoltageStandardMounting
AccuracyClass
Others
SC
Marine type:
Pushing tight type
Pushing tight type
Single row
vibrating reed
Reed Frequency Meter
Reed Type Structure
Ammeter and Voltmeter with AlarmIt is used in the aspect of control, measurement and alarm of electrical system. The symbol letter is A.
Technical specification of alarm system:Alarm value display: 90 argraph circular display, the bargraph consists of 46 pcs LED.Alarm point: By adjusting the forward button, each alarm point could be separately set.Intervention delay: Select different time delay by the front built-in switch, and singly select intervention delay for each alarm.Selectable time: 1s, 3s, 6s and 15s.Alarm model: Several alarm models can be selected by adjusting the forward jumper.Alarm indication segment: The segment was displayed by a lighting bargraph. When the pointer comes within the alarm segment, an alarm signal willutter, whereupon, the users can adopt relative alarm activity (like cut off power or externally connect a butter) according to their own needs. At thesame time, the LED fixed within this segment will flash: when the pointer leaves the alarm segment, the alarm state automatically terminate.Signal consumption: Ammeter 0.25VA(In 1A) , 0.5VA(In 5A) Voltmeter 0.1VA(In 500V)Hysteresis: 2.5% FS(special requirement is available on request.) Accuracy: 2.5% In Alarm output: 2 relays output, each relay has a set of normally open contact and normally closed contact. Contacts range: AC 250V 5A,DC 30V 5A.
Picture
AC /DC Ammeter and Voltmeter
with Alarm1 max contact + 1 min contact
AC /DC Ammeter and Voltmeter
with Alarm2 max contact
Type SpecificationCharacteristics
OthersStandardMounting
AccuracyClass
Auxiliary Power
Pushing tight type
AC Ammeter
AC Voltmeter with front movement
cover
Maximum Demand IndicatorThe thermal/time characteristics of MDI meters monitor the most economic use of cable, fuse gear and transformer. There are three kinds as follows.
A) Maximum Demand AmmeterWith bimetal movement and thermal delayed indicator for measuring the maximum means load during a period of 8, 15 or 30 minutes, eats red maximum pointer. Lead seal can protect resetting knob of maximum pointer. Scale compressed at the beginning, convenient reading from 25% of the ful l scale deflection. Accuracy of maximum load indication is 3%. Referred to the maximum pointer. Response t ime is 8, 15 or 30min can be customized. The symbol letter is M.
B) MDI with Moving Iron AmmeterFor measuring mean maximum contect value and instantaneous value for combined with moving iron movement meters. The accuracy class for instantaneous is 1.5. The symbol letter is 2M.
C) MDI with RelayFeatures: For the control of maximum demand and the monitoring and control of overload on distribution system. Constructed with an electroniccircuit and 5A relay. The alarm was set by the blue slim pointer; the red light is the alarm one, which can be used with buzzer. The symbol letter is AM. Accuracy class: 3.0, Burden: 2.6VA. Bestrews<1% Alarm and Trip: 1 second approximately fixed.Operating temperature: -10 ~+50 Auxiliary power: AC 220 10% 50/60Hz.Operating range: 20-100% 1% plus MDI accuracy . Relay raring: AC 250V 5A DC 24V 2A resistive. Overload: x 1.2 continuous, 10 times overload within 1s, 20 times overload within 1s via 5/5CT. Interchange able scale plate: open the seal and ins ert or pull out the scale plate. Under the same secondary current, the scale plate can be changed without loss the accuracy.Internal /1A or /5A can be customized.
Indicating the phase synchronization of three-phase alternating current system or two single phase system three -phase systems or between system and generator. When the frequency-error between generator and system is less than 0.5Hz, and the phase error is between 345 ~15 . The upper green light will flash.The power consumption: 4VA. The symbol letter is S-D type. According to the client s' requirements, the output function of relay can be customized. The symbol letter is S-DR.
Digital Synchroscope
Digital Synchroscope
with Relay
Pushing tight type
Marine type:
Operating frequency:
Pointer Synchroscope
Picture Type Specification OthersStandardMounting
Operating frequency:
Marine type:
Phase synchronization measurement (frequency and phase equality) between two single phase or three-phase alternating current systems, or between
system and generator. Indicates the synchronizing moment when frequency and phase of two sources have the same values. Then, pointer will be on
the upper center of scale. The symbol letter is S. Working time: Maximum 15 min.
Synchroscope
single phase
Synchroscope
Three-phase
Flush mounting with bolt
Hours Run Meter features six-digit readout with no reset function, making them virtually tamper proof. All hour meters are connected in parallel with the equipment bein g monitored. The synchronous motor provides accurate hour indication. The symbol letter is H.Display: 99999.9 Note: KLY-H48 is joint installation with pack, the mounting depth is 65mm.
Picture Type Specification OthersStandardMounting
Pushing tight type
Square Hours Run
Meter
50Hz,
60Hz,
400Hz
Operating frequency:
Marine type:
Net Insulation MonitorConduct monitoring for IT network insulation against ground, and utter alarming signal when the network suffers abnormal low insulation. The measuredvalue (reading) is indicated by analogue meter. The symbol letter is NI. The electronic measurement part of the net insulation monitor can be imbedded or externally attached.The output alarm value can be set according to users' demands. The meter can utter an alarm signal when the electrical network insulation resistance is lower than the set point. User can adopt relative alarm activity(like externally connect a buzzer) accordi ng to their own needs. When the electrical network insulat ion resistance returns to normal, the alarm state will automatically terminates.Alarm signal output: reply has a set of normally open contact and a set of normally closed contact . Capacity of alarm output contacts: DC 30V, 5A; AC 250V, 5A.Under power-up state with NO (normally open contact), relay responds to a measurement value below the set alarm value with shift ing from open contact to closedUnder power-up state with NC (normally closed contact), relay responds to a measurement value above the set alarm value with shifting from closedcontact to open contac t On interruption of power supply of relay, it will also shift from the closed contact to open contact.Within the same network, two sets of monitoring devices cannot be used simultaneously or to be used with other device simultaneously to measure the insulation resistance.Two insulation resistances of grounding system undertake real-time monitor. The double display heads in insolation monitors within the fission dual-circuit power system can signal insolation monitoring value. The shape can be KLY-2NI96I.
Note: When the set point needs to be changed, please conduct it under voltage free condition.
Picture
AC Net
Insulation Monitor
Two-in-one NI-I type
Insulation MonitorDC Net
Two-in-one 2NI-I type
Two Circuit NetInsulation Monitor
Pushing tight type
Pushing tight type
Pushing tight type
50Hz,
60Hz,
400Hz
(SC)
Marine type:
Operating frequency:
Type SpecificationOperating
VoltageAuxiliary Power
AccuracyClass
StandardMounting
Others
Special Symbols
Other Requirements
The dimension of Separated Type Net Insulation Monitor
Indicating the phase and voltage synchronization between system and generator. When volage and phase'value between generator and system are same, the LED light goes dim. The symbol letter is S-DT.
FeaturesProduct StructureTechnical Symbols Current
Pushing tight type
Pushing tight type
Pushing tight type
Pushing tight type
Pushing tight type
Pushing tight type
Active Power Meter
Single-phase system
Power Meter
Square Type Meter Square Type Meter
> This ind icator i s design ed for eas y testin g of phase s equenc e in three-phase systems with operating voltage up to 500V. For short connections, not longer than 5 minutes for one test, a push-button switch is placed on the front plate. A disc with an indicating arrow rotates in the direction of the arrow, if the three phases are properly connected; otherwise the disc rotates in the other directing. By changing the connecting of two wires, the phase sequence will be corrected to corresponding designation of the terminals. The symbol letter is SI.
Indicating the connection of phase sequence is corre ct, wrong or lack. A),when connected right, CORRECT lights up; B), when connected wrong, WRONG lights up; C), when phase bein g lacked, CORRECT& WRONG lights up simultaneously, at the same time the unlit light among L1,L2,L3
indicates the lacked phase. The symbol letter is SI-D. Relay output function can be customized, with symbol letter SI-DR.
>
50Hz,60Hz,400Hz
(SC)
Marine type:
Operating frequency:
Analog power factor meter is composed of a core-magnet moving coil movement and a built in or a separate power factor converter. Measure the power
factor (cos )of single-phase circuit or three-phase three-wire balanced load circuit. The power factor converter determines the cos phase angle
between current and voltage. COS is displayed at the moving coil movement.
When the meter has a separate power factor converter, is externally connected with one set of DIN Rail KLY-365 power factor converter (size: length
87.2 width 36.5 height 65.5. mm ) without exception. For the external dimension of the converter, see figure 1 on page 20.
When used in higher voltage, must be connected to a PT with a secondary voltage of 100V or110V.
When used in higher current, must be connected to a CT with a secondary current of 5A or 1A.
>
>
>
Product StructureTechnical Symbols
Power Factor Meter
Power Factor Meter
Power Factor Meter
With front
cover(F)
250
250
Pushing tight type
Pushing tight type
Pushing tight type
50Hz,
60Hz,
400Hz
(SC)
Marine type:
Operating frequency:
KLY series
with frontcover
(F)
CP series without frontcover
(C)
Analog power meter is composed of a core-magnet moving coil movement and a built in or a separate power converter. Power meters are intended for
measuring active and reactive power in single phase or three phase networks, with balanced or unbalanced load. Symbol letter: active power is
W and reactive power is Var.
When the meter has a separate power fac tory converter, It is externally connected with one set of DIN Rail KLY-725 power factor converter (size: length
87.2 width 72 height 68.5. mm ) without exception. For the external dimension of the converter, see figure 1 on page 20.
When used in higher voltage, must be connected to PT with secondary voltage of 100V or110V.
When used in higher current, must be connected to CT with secondary current of 5A or 1A.
When these meters externally connected with potential transformer in three-phase four-wire system, please specify line voltage or phase voltage.
Explosion-proof meters comply with explosion-proof standard. It has obtained PCEC explosion-proof certification of China. The meters can be applied to chemical industry. The symbol letter is E.
The performance of explosion-proof meters comply with IEC60079.0:1998, IEC60079-7.1990, GB3836.1-2000, GB3836.3-2000 standard. The explosion-proofmark: Ammeter: Exe T6 Voltmeter: Exem T6
Explosion-proof
Voltmeter
Explosion-proof
Ammeter
DIN Rail type
Rated Value Voltmeter
Picture Type Specification OthersMountingAccuracy
Class
Pushing tight type
Type Specification Others StandardMounting
FeaturesProduct StructureAppearance
AccuracyClassTechnical Symbols
Marine type:
OthersFeatures
AppearanceIndicating Angle
Pushing tight type
Pushing tight type
Picture
Type Specification StandardMounting
AccuracyClass
Picture
Non-electric Units Indicator
Non-electric Units Indicator
Moving Coil Movement
0V VoltmeterThis meter is mainly used for measuring the voltage difference between the power network and generator set. It is suggested to be used together with frequency meter.It is applied to closing by hand. Structure type: moving iron structure.Full-scale voltage is as 2 times as the rated voltage. 2/3 of full-scale voltage is the rated voltage value.
Non-el ectric U nits Ind icator s are indi cating ins truments which work by receiving electronic signals from transducers or control instruments. The indicating parameters are the physical value designated by the user. For instance: rotation speed, revolution, speed, flux, pressure, weight, PH value, temperature, etc. Its symbol letter is C. Any specifications can be customized according to customers' requirements.
Square Type Meter Square-Round MeterRectangular-Round Meter
Square-Round
Transparent cover:Single color (T) or Double color (S)
Back cover:Back turning cover(F)Back tight cover (J)
Mounting screw:Two mounting screws or four mounting screws
The range of measurement of Square-round and Rectangular-round meter (KLY-50, 560, 60, 670, 780, 80, 8100, 801, 1101, 01, 02, 03, and 04) is same as KLY square.
The measurement range of DIN Rail meter (KLY-45, KLY-72) is the same as KLY Square Type Meter. Refer to page 1 to page 14 for more details.
Product Details
Mounting of KLY series
Dimension of Rectangular Type Meter
AC Voltmeters with Rectifier Moving Coil Movement
KLY-D3Lengthened
AD
B8
7.2
45
20
32
45.3
42
45.3
8
6435
51.7
19
.7
8.5
62
.7
30.6
Product StructureTechnical Symbols
Am
ou
nt o
f co
nn
ecti
ng
te
rmin
als
Connecting to PT
Reactive Power Meter
Active Power Meter
Reactive Power Meter
AccuracyClass
Digital Parameter Meter
22Http://www.complee.com21 Http://www.complee.com
Digital Parameter Meter
Digital AC/DC Ammeter and Voltmeter
>
Simultaneously measuring current, voltage, power factor
Simultaneously measuring current, voltage, power
>
Measuring and displaying the active power and reactive power in balanced or unbalanced electric circuit.
>
>
Digital Intelligence Parameter Meters offer: alarm output, analogue output and communication output. (One or several outputs are available upon request)
>
CP-D72A
CP-D96A
KLY-D72A
KLY-D96A
KLY-D120A
CP-D72V
CP-D96V
KLY-D72V
KLY-D96V
KLY-D120V
KLY-D72F
KLY-D96F
KLY-D120F
KLY-D72PF
KLY-D96PF
KLY-D72W
KLY-D96W
Measuring range:0~360 phase angle
Operating current:1A,5AOperating voltage:AC 100V,
220V,380V
AC 110V 10%
AC 220V 10%
DC 24V
0.5
50Hz
60Hz
4
4
3 12
AC 10~600V
DC 60mV~600V0.5
4
3 12
Measuring range:1~9999Hz
Operating voltage:AC 100V,220V,380V
0.1
0.5Measuring range:
0~9999MWOperating current:1A,5A
Operating voltage:AC 100V,220V,380V
4
AC 100mA~10A
DC 1mA~10A
3 12
4
50Hz
60Hz
3 12
412
4
4
4
412
4
4
4
Bargraph
and
LED
display 4
4
KLY-D3A
KLY-D9681A
KLY-D840A
KLY-D3V
KLY-D9681V
KLY-D840V
KLY-D3F
KLY-D9681F
KLY-D3PF
KLY-D9681PF
KLY-D3W
KLY-D9681W
KLY-D1101A
KLY-D1101V
KLY-D365A
KLY-D725A
KLY-D365V
KLY-D725V
DIN Rail
Type Digital
Ammeter
3 12
3 12
3 12
3 12
50Hz
60Hz
50Hz
60Hz
KLY-D9681
KLY-D3
KLY-840
Digital Meters
Digital Frequency Meter
This kind of meter is widely used in power systems and other systems, measuring and displaying frequency value.>
>
Digital Power Factor Meter
Measuring and displaying the power factor in three-phase system with balanced load or single-phase system.
Digital Power Meter
Digital Three-row Combination Display Meter
Simultaneously measuring three-phase current or voltage
Simultaneously measuring current, voltage, frequency (KLY-D120A.V.F)
Digital Intelligence Parameter Meter
Digital Intell igence Parameter Meters are multi-function meters with alarm output, analogue output and digital communication. They are widely
applied in power supplying and distributing systems.
Communication output: RS485 communication interface (bus) adopts MODBUS-RTU communication protocol. All the obtained data and parameters can
be read from the position machine via the RS-485 interface.
PictureProductName
Type SpecificationAuxiliary Power
Accuracy Class
StandardMounting
Charact-eristics
Others
Max Display Digits
Operating Frequency
Other Functions
Square
Type
Digital
Ammeter
Square
Type
Digital
Voltmeter
Square Type
Digital Frequency
Meter
Square Type
Digital Power
Factor Meter
Square Type
Digital Power
Meter
Three-row display
current ratiosettable
voltage ratio
settable
PictureProduct Name
Type Charact-eristics
Others
Max Display Digits
Operating Frequency
Other Functions
RS485 serial port4-20mA outputRelay output
1 max contact +1 min contact meters
with relay
Current ratiosettable
Voltmeter ratiosettable
Please see
dimension
diagrams
on page 19
Figure 1
Rectangular
Type
Digital
Ammeter
Rectangular
Type
Digital
Voltmeter
Rectangular
Type
Digital
Frequency
Meter
Rectangular
Type
Digital Power
Factor Meter
Rectangular
Type
Digital Power
Meter
Square-round Type
Digital Ammeter
Square-round Type
Digital Voltmeter
DIN Rail
Type Digital
Voltmeter
>
>
>
Measuring and displaying the current and voltage in electric power network and automation control system. Owning the advantages of direct-reading, high accuracy, stability and antivibration.
Pushing tight type
Pushing tight type
Comply with the National Standard GB/T 22264-2008.>
7. 3P3W Voltmeter with Selector SwitchKLY-Z72.96.120.144
8. 3P3W Ammeter with Selector Switch
KLY-Z72.96.120.144
Connection Diagram
10.
KLY-Z72
3P4W Voltmeter with Selector Switch
L1L2L3N
2 31 42CT
L1L2L3
****
2 313CT
L1L2L3
****
*
2 31
*
5
12.
KLY-Z72
3P4W Ammeter with Selector Switch
L1L2L3
****
2 31
L1L2L3
****
*
2 31
*
42CT 3CT
96(H) 96(W) 100(D)Cutout size:
92(H) 92(W)Extensions:125(D)
R S485serial port
2 relay output
4-20mA analog output
Relay (7 circuit) input and output
96(H) 96(W) 100(D)
Cutout size:
92(H) 92(W)
Extension:125(D)
KLY-3432B
KLY-3430B
KLY-3431B
It integrates comprehensive display of three-phase AC parameter measurement, harmonics measurement and analysis, out-of-limit relay signal
output and network communication, which makes it easy to realize intelligence.
This product could be widely applied to: distributed power system monitoring, comprehensive automation system for transformer substation, unattended
transformer substation, intelligent low voltage distribution system, intelligent switchgear/switchboard, intelligent Box Transformer Substation and BAS.
Test objects are (45~65)Hz three-phase AC voltage and current signal, as well as 400Hz medium frequency signal.
Applicable to any standard/nonstandard secondary PT and CT signals, as well as the variable ration of settable PT and CT. Connection method could be
three-phase three-wire(two elements or three elements) or three-phase four-wire, single-phase. All the measured signal values are TRMS, which is also
applicable to the signal of wa ve disto rtion. Comm unication interface, power supply, voltage input, current inp ut and relay output are separated from
each other, which guarantee the product reliability.
Serialport:RS485
4-20mA analog output
Relay (7 circuit)
input and output.
Serial port:RS485
4-20mA analog output
Relay output
48(H) 96(W) 105(D)
Cutout size:
44(H) 91 (W)
KLY-D414
KLY-D433Voltage (500V), current (5A), power, power factor,frequency, energy, parameter setting(three-phase)
74(H) 82(W) 142(D)
KLY-1601
KLY-1602
KLY-1603
KLY-1604
KLY-1605
KLY-1606
KLY-1607
KLY-1618
KLY-1619
AC Voltage 500V(single-phase)
AC Cunent15A(single-phase)
Active power(500V/15A)(single-phase)
Power factor0.2-1.0(single-phase)
Frequency45-65Hz(single-phase)
Reactive power(500V/15A)(single-phase)
Active power(500V/15A)(single-phase)
Voltage (AC,RMS) 500V
Current (AC,RMS) 15A or 75mV input
KLY-2613
KLY-3414B
KLY-3415B
96(H) 48(W) 105(D)
Cutout size:
91(H) 44 (W)
96(H) 96(W) 100(D)
Cutout size:
91(H) 92(W)
Extensions:125(D)
Voltage and current could
both set ratio
Serial port RS485
4-20mA analog output
1 max contact + 1 min
contact meters with relay
Power factor, Frequency (single-phase AC),
KLY-2613
KLY-3414B
KLY-1601
(3) Digital Power Transducer (35mm DIN Rail Installation)
Panel Intelligence Network Parameter Meter
Picture Type Parameters and Range Dimension Other Functions (optional)
Three-phase voltage 500V
Three-phase current 5A
(2) Reeled Digital Meter (single-phase 0.5 Grade)
Picture Type Parameters and Range Dimension Other Functions (optional)
Voltage 500V, Current 20A, Power (U x I)
Picture Type Parameters and Range Dimension Other Functions (optional)
Voltage (500V), current (20A), power, power factor,frequency, energy, parameter setting (single-phase)
This label connection diagram is suitable for meters of different type but with same structure. When connecting, please make sure the connecting
terminal in the connection diagram is corresponding to the actual terminal on the meter. The actual connection diagram supplied with products
may differ from the cataloge diagram.
1. AC Ammeter 2. AC Voltmeter , Frequency Meter 3. DC Ammeter
(1) Reeled Intelligent Network Power Meter (three-phase 0.5 Grade)
Ammter and Voltmeter with Selector Switch
Three-phase voltage (500V), three-phase current(5A), active power, reactive power, apparent power,power factor, frequency, active electric power, reactive electric power, voltage imbalance, current imbalance,required current(DI), required active(DP), requiredreactive (DQ), required apparent power(DS), harmonicwave analysis(Har) -- 1-50 times, event record
Three-phase voltage 500V, current 5A, split phase and total active power, reactive power, apparent power,power factor measurement, forward and backwardactive electric power, reactive electric power, apparent electric power, frequency
Voltage 500V, current 20A, active, reactive, apparent
Digital Synchroscope 50. KLY-S96-DR-A.KLY-S96-DR-B
Digital Synchroscope
KLY-S72-DR-A.KLY-S72-DR-B
Net Insulation Monitor
7 8 9
RelayNET
6 5 123
POWER
AC 380V or
50/60Hz
7 8 9
Relay
NET
6 5 123
POWERDC 24V
+-
+ -
51. Net Insulation Monitor
KLY-NI96I.KLY-NI72I
KLY-NI96I-G
Auxiliary Power AC220V/380V
52. Net Insulation Monitor
KLY-NI96I.KLY-NI72I
KLY-NI96I-G
Auxiliary Power DC24V
Relay6 5
123
4
10
11
12
Relay
7
8
9
NET NET
POWER
AC 220V
AC 380V
50/60Hz
+ - -+
POWER
DC 24V
Relay6 5
123
4
10
11
12
+ -
Relay
7
8
9
NET NET
53.Net Insulation Monitor
KLY-2NI96I
Auxiliary Power AC220V/380V
54.Net Insulation Monitor
KLY-2NI96I
Auxiliary Power DC24V 66. Three-row Display Digital Voltmeter
KLY-D120
68. Digital Current Voltage Frequency
Meter (Three-row Display)
KLY-D120
AC 220V
1
4
7 865
3
2
Model
Spec
Input
Display
AC220V
I1
I3
I2
1
4
7 865
3
2
Model
Spec
Input
Display
U1
U3
U2
67. Three-row Display Digital Ammeter
KLY-D120
62. Double Reed Frequency
Meter with Two Rows of Reeds
KLY-2R96
61. Phase Sequence Indicator
KLY/CP-SI96,72
B CA
L1
L2
L3
B C A E
64. Double Voltmeter Frequency Meter
KLY-2T72.KLY-2T96
KLY-2F72.KLY-2F96
1 2 3 4
63. Double Reed Frequency Meter
with Two Rows of Reeds
KLY-2R144
1 3 15 17
65. Double Voltmeter Frequency Meter
KLY-2T144
KLY-2F144
1 3 13 7
+ AC/DC 24V
Aux Voltage
SingnalTerminal
-
1 35 8
+ AC/DC 24V
Aux Voltage
SingnalTerminal
-
2 81 7
55. Voltmeter with Auxiliary Lighting
KLY-C96V-G
57. Ammeter/Voltmeter
with Auxiliary Lighting
KLY-C72-G
+ AC/DC 24V
Aux Voltage
SingnalTerminal
-
3 41 2
58. Ammeter/Voltmeter
with Auxiliary Lighting
KLY-9681.KLY-9682G
+ AC/DC 24V
Aux Voltage
SingnalTerminal
-
3 91 7
59. Ammeter/Voltmeter
with Auxiliary Lighting
KLY-1101-G.KLY-T96A/V
+ AC/DC 24V
Aux Voltage
SingnalTerminal
-
5 81 3
56. Ammeter with Auxiliary Lighting
KLY-C96A-G(4-20mA)
+ AC/DC 24V
Aux Voltage
SingnalTerminal
-
11 161 3
60. Ammeter/Voltmeter
with Auxiliary Lighting
KLY-144
40. Three-phase Four -Wire
Unbalanced Load
(Active/Reactive)Power Meter
CP-W80.48
KLY-W8100.80.780.670.65.60.560.50.
48.45.801.9681(9682).KLY-W48-G
41. Three-phase Four -Wire
Balanced Load
(Active/ Reactive) Power Meter
CP-W80.48
KLY-W8100.80.780.670.65.60.560.50.
48.45.801.9681(9682).KLY-W48-G
42.Three-phase Four -Wire
Unbalanced Load
(Active/Reactive) Power Meter
KLY/CP-W72.KLY-W72-G
KLY/CP-W96.KLY-W96-G
43.Three-phase Four -Wire
Balanced Load
(Active/Reactive) Power Meter
KLY/CP-W72.KLY-W72-G
KLY/CP-W96.KLY-W96-G
Connection Diagram Connection Diagram
Three-phase Four-wire Active/Reactive Power Meter
Synchroscope
Meters With Auxiliary Lighting
AC 220V
Model
Spec
Input
Display
7 865
1
43
2
AC220VAC110V
U
I
Notice
Switchgear Distribution System Generator Sets
Control System Overload Protection
Complee 's Current Transformer is designed for indoor conditions. Its Rated Frequency is 50 or 60 Hz and can measure electric in AC electric system up to
0.72kV. It can also be used for electrical energy measuring and relay protection.
Our products are produced with strong Anti-fired material case and high quality silicon material with high magnetism. The welding wire of CT is stuck with
strong polyester.
Under special conditions, we can choose the special wire which is high temperature packed with strong stickness polyester. All the terminal has its obvious mark.
Our products are popular with their firmness, excellent workmanship, strong resistance to vibrat ion and ea sy inst allati on char acterist ics.
1. It is inadvisable to have a high transformer current ratio of margin, which may influence product precision;
2. The total resistance for welding and panel meter should be lower than the rated burden of the nameplate required;
3. Open circuit is forbidden in secondary winding of transformer in use;
4. The polarity for Current Transformer should be checked and confirm it is correct before being used.
We use P1&P2 as mark for primary welding and S1&S2 as mark for secondary welding.