Company Profile

Energy Mapping & Energy Projects

Innovation in Energy Efficiency & Green-Energy

Energy Policy & Energy Team

Our Achievements –Energy awards

ISO 50000:2100 Road Map

Future Road Maps towards Excellence

Page 3: Company Profile - Green Business Centre · Company Profile Energy Mapping & Energy Projects ... 1 Energy Saving by Arresting of Air-Leakage in HRD & Optiisation of Pressure 34.5 245.8

3

▪ Set up in 1970 by its founder & Chairman Late Sh O.P. Jindal

▪ Stainless steel production started in 1979, with setting of first AOD converter in the country.

▪ Largest integrated stainless steel plant in the country.▪ ISO-9001:2015,ISO-14001,OHSAS-18001,AD, PED, CPD certified company

HOT ROLLING DIVISIONCOLD ROLLING DIVISION

LATE SH. O.P. JINDAL

Page 4: Company Profile - Green Business Centre · Company Profile Energy Mapping & Energy Projects ... 1 Energy Saving by Arresting of Air-Leakage in HRD & Optiisation of Pressure 34.5 245.8

▪ Jindal Stainless is one of the largest stainless steelconglomerates in India and ranks amongst the top 10stainless steel conglomerates in the world

▪ Jindal Stainless Group has an annual crude steel capacityof 1.8 MTPA and the group has an annual turnover of Rs16,500 crores

▪ Since its inception, Hisar plant was integrated on astrategy of both, backward and forward, starting frommining, melting, casting, hot rolling to cold rolling andvalue additions

▪ Today, it is a fully integrated Stainless Steel plant capacityof 780,000 TPA

▪ It is also the world ’s largest producer of steel strips forrazor blades and India’s largest producer of coin servingthe needs of Indian and International mints

Page 5: Company Profile - Green Business Centre · Company Profile Energy Mapping & Energy Projects ... 1 Energy Saving by Arresting of Air-Leakage in HRD & Optiisation of Pressure 34.5 245.8
Page 6: Company Profile - Green Business Centre · Company Profile Energy Mapping & Energy Projects ... 1 Energy Saving by Arresting of Air-Leakage in HRD & Optiisation of Pressure 34.5 245.8

6

0

100

200

300

400

500

600

Steel MeltingShop

Hot rolled coils Cold rolledCoils

508

136

358

507

139

365

512

136

353

490

138

329

2014-15 2015-16 2016-17 2017-18

KW

H/M

T

0.50

0.55

0.60

0.65

0.70

0.75

Hot rolled coils Cold rolled Coils

0.61

0.71

0.59

0.68

0.58

0.68

0.54

0.63

2014-15 2015-16 2016-17 2017-18

Specific Electrical Consumption KWH/MT Specific Thermal Consumption KWH/MT

0

50

100

14.7 19.6 21.07

94

2014-15 2015-16 2016-17 2017-18

Power Saving in Lacs KWH

KW

H in

lacs

KW

H/M

T

Page 7: Company Profile - Green Business Centre · Company Profile Energy Mapping & Energy Projects ... 1 Energy Saving by Arresting of Air-Leakage in HRD & Optiisation of Pressure 34.5 245.8

42%

25%

33%

% Share of Energy Source type

Electricity Fuel Oil Propane Gas

21%

34%

45%

% Share of Energy Process Wise per MT

Steel-Melting Hot Rolling Cold Rolling

Outokumpu 12.8 GJ/Ton , Aperam 9.8 GJ/Ton , JSHL – 8.09 GJ/Ton ( Include elect & thermal on crude steel Year 2016)

Source – At company Website environment foot print data

Page 8: Company Profile - Green Business Centre · Company Profile Energy Mapping & Energy Projects ... 1 Energy Saving by Arresting of Air-Leakage in HRD & Optiisation of Pressure 34.5 245.8

Sr. Details of ProjectsElectricity

Thermal Saving

Total savings

Investment

Lakh kWH (MTOE) Rs. Lakhs Rs. Lakhs

1 Energy Saving by optimizing speed of Z-2 Mill Blower motor w.r.t. mill speed. 2.23 17.730 6.90

2Energy Saving by Optimizing speed of Z-1 LTR Motor Blower motor

w.r.t. mill speed.0.069 0.550 0.60

3 Energy saving by Optimizing speed of Z-1 RTR Motor Blower motor w.r.t. mill speed. 0.12 0.920 0.40

4 Energy Saving by Optimizing speed of Ventilation w.r.t. mill speed. 0.40 3.230 0.60

5 Energy Saving by Program modification in Fume Exhaust motor speed in first two pass. 0.37 2.940 0.00

6Energy Saving by Program modification in Primary Pump to switch o침垘 the pump in Roll Change

Mode.

0.05 0.360 0.00

7 Energy optimization in pickling pumps HNO3. 0.60 4.830 0.00

8 To optimize the Energy consumption in Jet Cooling blowers. 3.42 27.360 0.00

9 Optimization speed of Hot Air-Blower using VFD. 0.48 3.800 0.00

10 Sherman-1 HP Pump is switched o침垘 during Rewinding Mode 0.27 2.130 0.00

11 Optimization speed of Sherman-2 Motor Cooling Blower using VFD. 0.19 1.530 0.00

12 Optimization speed of PTF-5 Strip Cooling Blower using VF 0.27 2.160 0.00

13 Optimization speed of PTF-6 Strip Cooling Blower using VFD. 0.26 2.100 0.00

14 Optimization speed of PTF-8 Strip Cooling Blower using VFD. 0.20 1.630 0.00

15 To reduce energy consumption by Gas Plant close loop water pump power optimization 0.25 2.000 0.00

16 To reduce energy consumption by Wider BA water pump replacement with lower rating pump 1.61 12.890 0.80

17 Reduction in steam consumption in AP lines of CRD 0.00 38.610 23.00

18 Reduction of Compressed Air consumption 8.85 14.91 70.780 7.50

19Reduction in Propane consumption in AP-2 & AP4 lines of CRD 0.00 16.000 1.50

20 19.62 211.550 41.30

Page 9: Company Profile - Green Business Centre · Company Profile Energy Mapping & Energy Projects ... 1 Energy Saving by Arresting of Air-Leakage in HRD & Optiisation of Pressure 34.5 245.8

Sr. Details of ProjectsElectricity

Thermal Saving

Total savings

Investment

Lakh kWH (MTOE) Rs. Lakhs Rs. Lakhs

1To Optimise power consumption of recoiler edge guide (Askania) hyd pump by switching it off in Auto during recoiler not running.

0.07 0.49 0

2To Optimise power consumption of Main hyd pump by switching it off after 5 minuts when no hyd. Operation is going ON.

0.95 7.15 0

3 Power Saving by Switch-Off rectifier when line is down 0.22 1.62 0

4 Oncoiler CPC Hydraulic Pump auto switch off during coil slitting mode is not select. 0.49 3.71 0

5 ETR-1 & Blower Motor Speed reduced to 60% during first Pass when coil runs from POR 0.31 2.33 0

6 Power Optimisation of Jet Cooling Blower 3.42 25.65 0

7 Stopping of Hot Water Pump after Modification, Hot water coming from bell furnace fall directly at cooling tower 2.2 16.5 1.5

8 Flat belt provision for Fume Exhaust blowers at RM-1 & SHM-1 0.41 3.1 1.5

9 Reduce Lye Cleaning Heater set point from 50 to 43 degree C. (216 Kw) 0.28 2.13 0

10 Reduce dryer heater set point from 80 to 75 degree C. ( 81Kw) 0.13 0.94 0

11 Step up transformer used for Main stand is to be removed.(to run the Mill at 415 V supply) 0.17 1.3 0

12 Providing Air knife system at dryer unit in place of Heating dryer system 1.82 13.63 2.1

13Set the cold water pump pressure to 2.1 kg in place of 3.4 kg by throttling the valve. Thus more than 300 units save per day.

1.09 8.18 0

14 Circulation pumps of Z1 mill to be run at 70% speed during mill idle time for optimum use of circulation pumps. 0.61 4.6 4

15 Field economy to be enabled in 06nos.DC motors during mill idle time AT Z-2 mILL 0.8 5.97 0

16 Energy saving by switching OFF recoiler blower motror during recoiler idle condition. 0.06 0.42 0

17 Z2 mill oil cellar ventilation unit running duration reduced from 24 hrs to 12 hrs. 1.05 7.91 0

18 Power saving by providing separate power packs at Annealing-1 & Pickling-1 1.04 7.78 5

19 Z2 mill ETR DC blower motor speed reduced from 100% to 60% during first pass when coil filled from POR. 0.31 2.34 0

20 Provide drive on Mixed pump (To control speed to optimize the flow) at AP-4 0.6 4.51 2.5

21 Provide drive on Nitric pump (To control speed to optimize the flow) at AP-4 0.59 4.39 2.5

22 Installation of reverse cubical unit at MDL2 at AP-4. 0.85 6.34 5

23To reduce Boiler fuel consumption by pre heating of feed water (soft water) through heat exchanger by quench hot water.

13.75 3.6 0.3

24 Installation of 250KWp Solar Plant 3.56 26.7 142

25 Replacement of 40W Tube light with 20W LED Tube 0.04 0.32 0.1

26 Reduction in energy in RO Plant , by optimising the RO High Pressure Feed Pump. 1.2 8.6 6.0

27 Reduction in energy in CCS -2 mould system at SMS 2 , by separate pump for Bloom Water. 3.3 24.5 2.0

28 Power Saving by Switching Off Three Roll Cooling pump 3.1 23.0 0.0

Page 10: Company Profile - Green Business Centre · Company Profile Energy Mapping & Energy Projects ... 1 Energy Saving by Arresting of Air-Leakage in HRD & Optiisation of Pressure 34.5 245.8

SR. Title of Energy Saving project implementedElectrical Savings

Thermal savings

Total Saving

Invest. Made

Lacs KWH TOE Rs Lacs Rs Lacs1 Energy Saving by Arresting of Air-Leakage in HRD & Optiisation of Pressure 34.5 245.8 5.0

2Energy conservation at SMS2 EAF & AOD ID fan by operating it by AC Drive in place of fluid copupling based DOL starter.

24.1 171.8 110

3 Installation of 400KWp Plant 5.5 39.2 186

4 Replacement of Conventional light with LED Light 8.3 59.1 60

5Hot Air dryer system replaced with Air Knife system at PTF-5,6&8 Lines to reduce steam and Power.

0.6 206.0 62.1 3.2

6Earlier return water falls in hot water tank and one 22Kw pump was used for hot water to cooling tower, After modification of pipe line hot water falls directly on cooling tower by gravity. Now this pump is permanently stopped.

1.68 12.0 5.0

7Earlier 55Kw two nos. Of pump running continuously so we have changed them with single 75Kw pump.

1.10 7.8 0.5

8 To stop Air quench fan-2 during line stop & Minor Projects 2.7 19.3 0

9 Saving by utilizing working hrs of Spray pump-3 on Z-2 Mill & Minor Projects 0.4 3.3 0

10 To Utilize Water requirement in 400 Series(by using 2 pumps only instead of 3) 0.4 3.1 0

11 To reduce Power consumption by using Double vane pump 0.3 2.5 0

12 Flow control of Mixed Acid Pumps by installing drive & other Minor Projecs 2.9 20.7 0

13Energy conservation at Auto Grinder ID Fan motor by replacing star-delta starter with AC Drive & optimising its running

4.4 31.3 0.88

14Energy conservation at Shot Blasting ID Fan motor by replacing star-delta starter with AC Drive & optimising its running

0.8 6.1 0.88

15Energy conservation at Top Lance by replcing existing 75KW AC motors & pumps with 30 KW Motors & high effeciency pump.

1.4 10.3 0.64

16Energy Conservation at Slab-Caster Steam Exhaust Fans by switching OFF these in auto after End of cast.

1.1 7.8 0.02

17 Saving of LSHS by installation of Air Preheater Unit in 6TPH Boiler(Efficiency improvement 2.5% ). 50.0 14.2 0

18 Calibration of Godrej Air Saver control mechanism 2.1 14.9 0

19 Replacement of inefficient pump -CCS Primary pump-10 1.3 9.7 0

20 Energy Saving by Reducing FLue Gas Leakage in WBF Furnace 343.5 9.5 0

Saving = 750.5 lakhs Investment= 372.12 lakhs 0.036% of Turn over

Page 11: Company Profile - Green Business Centre · Company Profile Energy Mapping & Energy Projects ... 1 Energy Saving by Arresting of Air-Leakage in HRD & Optiisation of Pressure 34.5 245.8

11

Problem Statement: Energy saving by arresting of air-leakage in HRD & Optimization of set pressure

Air Consumption UOMDaily Average JAN

2017Daily Average Feb

2017Daily Average March 2017

Average Q-4 16-17

SMS-1 NM3/Day 122919 126287 128079 125762

SMS-2 NM3/Day 68174 69409 71592 69725

STECKEL MILL NM3/Day 88928 78696 79586 82403

STRIP MILL NM3/Day 12087 12473 15163 13241

FINISHING NM3/Day 33471 34636 32076 33394

Grinders NM3/Day 12352 12580 11926 12286

S.A.F. NM3/Day 34841 33876 30424 33047

CU. NI. NM3/Day 2924 3792 1862 2859

Total Air Consumption

NM3/Day 375696 371749 370708 372718

Power Consumption KWH/Day 42279 42275 41092 41882

Previous Data (Benchmark data Q-04 2016-17)

Page 12: Company Profile - Green Business Centre · Company Profile Energy Mapping & Energy Projects ... 1 Energy Saving by Arresting of Air-Leakage in HRD & Optiisation of Pressure 34.5 245.8

Key Steps Executed:

1. Leakages arresting at different usages points

2. Monitoring & measurement of air flow at different sections

3. Building audit team to check the daily consumption section wise against targets

4. Optimization of timing at dust bag filter at SMS 1 & SAF 1

5. Replaced the pipe nozzles by spray nozzles at finishing section at plate pickling & short blasting

6. Replaced the manual operating valves by the solenoid operated on/off valves at SMS 1 & 2 Dust filtration system

7. Rescheduling of timing at Air conveying at SMS-1

8. Installation of PRVs at different locations of HRM

9. Blowing of air in instruments stopped for laminar cooling when laminar is in idle

10. Set pressure at the compressors has been reduced from 6.5 to 5.8 bar

11. Replaced the pipe nozzles by spray nozzles at Cu-Ni rolling mill

12. Air blowing stopped at clarifier of ETP at Cu-Ni plant

Page 13: Company Profile - Green Business Centre · Company Profile Energy Mapping & Energy Projects ... 1 Energy Saving by Arresting of Air-Leakage in HRD & Optiisation of Pressure 34.5 245.8

Total Energy Saving Calculation:

▪ Average air consumption/day (Q 4 2016-17)= 372718 Nm3

▪ Average air consumption/day (2017-18) = 292005 Nm3

▪ Reduction in air consumption/annum = (372718- 292005)*365 days

▪ Reduction in power (kwh/annum) = 80713*365*0.122 kwh/nm3* = 35,94,150 Kwh

▪ Annual Saving in Rs. = 35,94,150 *7.5/100000=Rs.269.56 Lakh

▪ Investments = Rs. 25 lakhs

▪ Pay back = 1.10 Month

Air Consumption

UOM Avg Q-1 (17-18) Avg Q-2 (17-18) Avg Q-3 (17-18) Avg Q-4 (17-18)Annual Avg(2017-18)

SMS-1 NM3/Day 109353 91080 84243 75625 90075SMS-2 NM3/Day 64214 53955 51244 51100 55128

STECKEL MILL NM3/Day 85910 69619 66085 63780 71348STRIP MILL NM3/Day 12151 13858 16004 11398 13353

FINISHING NM3/Day 23580 24999 20799 20105 22370Grinders NM3/Day 12862 9211 8485 7989 9637

S.A.F. NM3/Day 24994 24371 28834 24711 25728CU. NI. NM3/Day 2480 5193 6189 3598 4365TOTAL NM3/Day 335544 292287 281882 258305 292005

Power Cons. Per day

KWH/Day 38726 36466 35556 31929 35669

Data After Project Initiatives

Page 14: Company Profile - Green Business Centre · Company Profile Energy Mapping & Energy Projects ... 1 Energy Saving by Arresting of Air-Leakage in HRD & Optiisation of Pressure 34.5 245.8

14

Problem Statement: To Reduce energy consumption at EAF&AOD ID FAN in SMSfrom 41.5 Kwh/ MT to 35.8 Kwh/ MT

Project start : 01.04.2017

Project End : 01.12.2017

Problem Identification:

▪ Electrical Power consumption is major aspect at EAF& AOD ID fan and high maintenance.

▪ Power consumption @ 41.5 KWH/MT of Stainless Steel

▪ Power consumption is about 14326160 KWH Per Annum

▪ Power costs about Rs. 11.5 crore Per Annum @ of Rs. 8 per KWH

FLUID COUPLING ID FAN1250 KW HT MOTOR

Page 15: Company Profile - Green Business Centre · Company Profile Energy Mapping & Energy Projects ... 1 Energy Saving by Arresting of Air-Leakage in HRD & Optiisation of Pressure 34.5 245.8

Analysis of Electrical Energy Loss:

▪ An audit of EAF & AOD ID FAN was carried out to check the energy consumed by EAF & AOD ID fan motors Thefollowing activities were carried out:

– Identified & analyzed that EAF and AOD ID fan motors (1250 KW) are 3.3KV motors and are being operatedthrough VCB

o These motors are coupled through fluid coupling with ID fans which is not energy efficient medium asapproximate 4% transfer loss

– Identified that speed variation is done through fluid coupling which is causing energy loss.

Due to Fluid coupling it is not easy to vary speed of ID fan motors as per process condition of Electric Arc Furnace (EAF) and Argon oxygen Decarburization Furnace(AOD) . Its vibrations increases during speed changeover period due to which unable to vary

speed frequently which is causing energy loss

Root cause

Solution Development:

▪ Installation of 1250KW,690V motors in place ofexisting HT motors

▪ Motors must be coupled directly with ID fans byremoving fluid coupling

▪ Motors must be operated through 1250 KW VFDdrives

▪ Speed of motors can be controlled easily with VFDdrive as per process requirement

ID FAN COUPLING 1250 KW ,690V LT MOTOR

Motors directly coupled with ID Fan

Page 16: Company Profile - Green Business Centre · Company Profile Energy Mapping & Energy Projects ... 1 Energy Saving by Arresting of Air-Leakage in HRD & Optiisation of Pressure 34.5 245.8

12707501197040

1134120 1167760 11486901244720

1125610 1132410998910 951760 983480

1043180

0

200000

400000

600000

800000

1000000

1200000

1400000

Apr-17 May-17 Jun-17 Jul-17 Aug-17 Sep-17 Oct-17 Nov-17 Dec-17 Jan-18 Feb-18 Mar-18

EAF & AOD ID FanEnergy Comparison before and after implementation of project

BEFORE AFTER

EAF ID FAN MOTOR COMMISSIONED = OCTOBER 2017AOD ID FAN MOTOR COMMISSIONED = DECEMBER 2017 ONWARDS

EAF ID fan motor commissioned

Both motors commissioned

Total Energy saving calculation:• Energy consumption before the start of project: 1193846 kwh/month

• Energy consumption after the project : 1039225 kwh/month

• Energy Tariff, Rs./kwh : 8

• Reduction in Energy (kwh): 154622 kwh/month

• Saving : 154622 *8 =Rs. 12.37 Lac/month

• Since Project completed in Dec’ 2017 so,

Total Saving annually : 12.37 *12= Rs. 1.5 Crore

Page 17: Company Profile - Green Business Centre · Company Profile Energy Mapping & Energy Projects ... 1 Energy Saving by Arresting of Air-Leakage in HRD & Optiisation of Pressure 34.5 245.8

17

Problem Statement: To reduce power and steam consumption at PTF lines

Existing System: Hot Air Dryer

Purpose: It is used to dry the strip which comes from degreasing process. So strip should be dry properly becausenext process is going to be furnace heating(Temp. around 750°C)

Degreasing section and Hot Air Dryer

Page 18: Company Profile - Green Business Centre · Company Profile Energy Mapping & Energy Projects ... 1 Energy Saving by Arresting of Air-Leakage in HRD & Optiisation of Pressure 34.5 245.8

Analysis:

▪ In brainstorming session, we have decided to observe strip dryness after20-25% throttling of dryer because we have two other lines having lowercapacity motor

▪ We observed for 5-7 days and found strip dryness ok so decided toinstall VFD and optimize it to 30Hz

▪ Then again we thought about how to reduce steam consumption andtried to go to internet for a system which can meet our processrequirements

▪ So finally we got to know about Air Knife systemConsumptionbefore VFD

Consumptionafter VFD

79576.7

58356.3

Kwh/Annum

Consumptionbefore VFD

Consumptionafter VFD

Solution Development:

▪ New Installed System: Air Knife System

▪ System Application:

– Drying of Metal sheets

– Sheet width: 600 mm max

– Sheet speed: 30 m/min

– Drying/Moisture Removal: Top and Bottom Surface

Page 19: Company Profile - Green Business Centre · Company Profile Energy Mapping & Energy Projects ... 1 Energy Saving by Arresting of Air-Leakage in HRD & Optiisation of Pressure 34.5 245.8

Total Energy saving calculation:

▪ Power Consumption before: 183026.4 Kwh/Annam

▪ Steam Consumption before: 242.3 Kg/MT

▪ Power Consumption after: 114060 Kwh/Annam

▪ Steam Consumption after: 44.25 Kg/MT

▪ Total Power Saving(Rs): 5.51 Lacs/Annam

▪ Total Steam Saving(Rs): 47.04 Lacs/Annam

▪ Investment: 2.1 Lacs

Total Overall Saving: 49.3 Lacs/Annum

System Advantages:

1. Improvement in product quality since absolutely no moisture is carried away along with the product

2. High efficiency of the Drying Process

3. The blower is fitted with 10 microns inlet filter and the air coming out of the blower is filtered

4. This is a high rpm blower with balanced and sealed impeller assembly to develop high air velocities for drying

5. The temperature of the outlet air is @ 8 to 10 degree higher than the ambient temperature, which further helpsin the drying process

6. This is a Constant Pressure System because of which there will be consistent product quality

Uniqueness of the system is that it used for energy as well as steam saving with low maintenance cost

Page 20: Company Profile - Green Business Centre · Company Profile Energy Mapping & Energy Projects ... 1 Energy Saving by Arresting of Air-Leakage in HRD & Optiisation of Pressure 34.5 245.8

1. Solar Plant -I. Installed 250KWp Roof-Top Solar Plant in CBL Roof in Sec.2016II. Installed 200KWp Roof-Top Solar Plant in HRD in Dec.2017III. Installed 200KWp Roof-Top Solar Plant in CRD Roof in Dec.2017IV. Installation of 200KWp Shed-Top Solar Plant Under-ProcurementV. 2.80MW Roof-Top Solar Plant Under-Discussion either in CAPEX or OPEX Mode

2. Solar Water Heater - Technical Discussion Under-Progress for Installation of Solar Water Heater for heating of Cafeteria & Canteen Water

3. Bio-Gas Plant - Installation of Bio-Gas Plant Under-Procurement for utilisation of Raw Veg/Cooked Food waste

200kw in pipeline

Page 21: Company Profile - Green Business Centre · Company Profile Energy Mapping & Energy Projects ... 1 Energy Saving by Arresting of Air-Leakage in HRD & Optiisation of Pressure 34.5 245.8

Major tasks: Development of new products

▪ Austenitic stainless steel EQ309L with high ferrite content foruse in weld overlay applications

▪ Heat resistant austenitic stainless steel UNS S30815 micro-alloyed with rare-earth cerium

▪ Highly corrosion resistant super-austenitic stainless steel –904L

▪ New austenitic grades for high temperature applications –304H and 347H

▪ Clad Stainless Steel plates in 350 mm width

▪ High thickness plates of 441 grades for gasket application

Process Improvement:

▪ Successfully produced hot-rolledduplex stainless steel UNS S32205down to 5 mm thickness

▪ Complete elimination of bow induplex plates after plate annealingby suitably modifying processingduring annealing and quenching ofplates

Cost Reduction & Green Efforts

▪ Suitable use of AOD dust, rolling millscale and grinding dust in EAF forconservation of metallic elementsand resources thru SAF route.

▪ FO oil sludge used in furnaces afterrefining process. Use of FO stoppednow .

▪ Improvement in grinding practice offerritic stainless steel grades leadingto cost saving

Total Kaizen 1090

Wastage handling

Page 22: Company Profile - Green Business Centre · Company Profile Energy Mapping & Energy Projects ... 1 Energy Saving by Arresting of Air-Leakage in HRD & Optiisation of Pressure 34.5 245.8

Environment Health and Safety (EHS) sustainability is an important item on the Company agenda

▪ Jindal Stainless Limited has undertaken numerous initiatives to realize improvements in this area

▪ Driven by an integrated 'Quality, Environmental, Occupational Health and Safety' Policy, Jindal Stainless Limited is now marching towards benchmarking its processes in the field of Qualify, Safety, Health and Environment

▪ The Company has demonstrated this by implementing Environmental Management System (EMS) & OHSAS Systems

The Organization has adopted a systematic strategic approach in implementation of its key manufacturing areas (KMFAS) to ensure zero pollution, zero accidents and a healthy and clean working environment

JSL focuses on the areas of Behavioural Safety, Process Safety and Ergonomic and General Safety

▪ Focused campaigns have been carried out inthe areas of Gas Safety, Material Handlingand Road Safety

▪ Thrust has been laid towards enhancingresource efficiency in operations, especiallyfor key resources such as energy and water

▪ Additionally the philosophy of the '3-R'(reduce, reuse and recycle) is beingimplemented for all types of wastes towardsprevention of pollution

State-of-the-art 'Centre for EnvironmentalExcellence', with sophisticated and well equippedEnvironmental Laboratory and R&D has been Set-up

▪ Efficient use of resources is being practicedthrough effective management practices,technological measures and employeeengagement process to make themenvironmentally aware and technicallycompetent

▪ The operations are dependent on the use ofnatural resources and have consequentlyincorporated energy management into its ISO9001; Quality Management Systems (QMS) andTotal Productive Maintenance (TPM) initiatives

The Company’s plants comply with all norms set up by the competent authorities for a clean and better environment

▪ The Company undertakes regular checks/inspections including certification for the maintenance of the environment

CO2 Emission

2.83 Kg / T of steel

Page 23: Company Profile - Green Business Centre · Company Profile Energy Mapping & Energy Projects ... 1 Energy Saving by Arresting of Air-Leakage in HRD & Optiisation of Pressure 34.5 245.8

CSR Initiative at Jindal Stainless Hisar

▪ SKILL TRAINING

▪ WOMEN EMPOWERMENT

– O P Jindal Vikas Kendra and Cutting & tailoring centre

– Save the Girl Child Project

▪ EDUCATION – Computer Learning Station (HIWEL - Hole in The WallProject)

▪ INTEGRATED HEALTH INITIATIVES

– HIV/AIDS Volunteer Programs

– Mobile Health Project

▪ COMMUNITY DEVELPOMENT - Organic Farming Project

▪ Women as change agents for fostering energy conservation

“Without the upliftment of weaker and backward sections of society our dream of being a leading nation of the world shall remain unfulfilled” -- Late Shri O.P. Jindal

▪ In relentless pursuit of the above philosophy of Late Shri O.P. Jindal, Jindal Stainless Limited has gone beyond thepursuit of the top and bottom-lines to embrace the community and its needs

▪ The Group’s contribution has encompassed every sphere of human interest, including education, sports, art andculture, health, environment, women empowerment, vocational training, agriculture, community developmentinitiatives, etc.

▪ Over the years the company has taken series of CSR initiatives in the form of projects

Page 24: Company Profile - Green Business Centre · Company Profile Energy Mapping & Energy Projects ... 1 Energy Saving by Arresting of Air-Leakage in HRD & Optiisation of Pressure 34.5 245.8

(SMS-2)

EL

(SMS-1)

EL

(HRM)

EL

(UTILITY)

EL

Energy Monitoring Cell

CEM , Daily monitoring SAP data

Monthly circulation to all HODs

Top Level

Management

Head OP & Director

(CR-2)

EL

(CR-3)

EL

(CR-1)

EL

(SAF) EL

(SPD)

EL

EL – Energy LeadersCEM – Certified Energy Manager

Meeting every month on PAT.EHS

CEM – 4 , CEA- 3 in the plant

Page 25: Company Profile - Green Business Centre · Company Profile Energy Mapping & Energy Projects ... 1 Energy Saving by Arresting of Air-Leakage in HRD & Optiisation of Pressure 34.5 245.8
Page 26: Company Profile - Green Business Centre · Company Profile Energy Mapping & Energy Projects ... 1 Energy Saving by Arresting of Air-Leakage in HRD & Optiisation of Pressure 34.5 245.8

ROAD MAP FOR Implementation of ISO 50001:2011 JINDAL STAINLESS HISAR (HARYANA)

S.NO ACTIVITY Responsibility2018

MAR APRIL MAY JUNE JULY AUG SEP OCT NOV DEC JAN FEB

1 Awareness training about the new standard QGS + MR

2Initial Energy Usage calcualation and consumption based on measurement (Part of Energy Review)

CFT

3Review of Energy Usage calcualation and consumption for all department

CFT

4Identification of Signficant Energy Consumption (Part of Energy Review)

CFT

5Identfication of Improvement Progams (PIPs) and Action Plans related to EnMS

CFT + HODs

6Review of Energy Performance Indicators (EnPIs) and baseline

MR + CFT

7Review and Upgradation of EnMS Manual as per the requirements of ISO 50001:2011

QGS + MR + Top Management

8Review and Upgradation of EnMS Procedures as per the requirements of ISO 50001:2011

QGS + MR

9Change in Policy, Approval and Display as per the requirements of ISO ISO 50001:2011

QGS + MR + Top Management

10Review and Finalization of EnMS Formats as per the requirements of ISO 50001:2011

QGS + MR

11Preparation of Work Instructions or Linkage with for Energy Management system

MR + CFT

12 Implementation of Documents on Shopfloor MR + CFT

13Future Energy consumption Methodology Identification and calculation for energy performance idicators

MR + CFT

14 Internal ISO 50001:2011 System audit training QGS

15 Internal Audit at the PlantTrained Internal

Auditors

16Management Review as per ISO 50001:2011 Agenda

MR + CFT

17 Shadow Audit QGS

18Certification audit for new transitionISO 50001:2011

Certification Body

Completed WeekStart Completed Completion Plan

Page 27: Company Profile - Green Business Centre · Company Profile Energy Mapping & Energy Projects ... 1 Energy Saving by Arresting of Air-Leakage in HRD & Optiisation of Pressure 34.5 245.8

Won 1st Prize

(Steel Re-Rolling Sector) in Year 2013

Won 2nd Prize(Steel Re-Rolling Sector) in Year 2011

Won 2nd Prize(Steel Re-Rolling Sector) in Year 2012

Won Merit Certificate(Steel Re-Rolling Sector) in Year 2015

Won 1st Prize(Steel Re-Rolling Sector) in Year 2007

Page 28: Company Profile - Green Business Centre · Company Profile Energy Mapping & Energy Projects ... 1 Energy Saving by Arresting of Air-Leakage in HRD & Optiisation of Pressure 34.5 245.8

Won Gold Award in SNEMA-2016 IN Category-Industries (Iron & Steel Sector)

Won 1st Prize in Energy Circle Competetion-2016 inBest Energy Efficient Case Study Organised by CII

Award Participation Certificate from Dept. of New & renewableEnergy, Govt. of Haryana in Industrial & Commercial BuildingCategory (Connected Load 01MW & Above)

Won Platinum Award in SNEMA-2017 IN Category- Industries (Iron & Steel Sector)

Page 29: Company Profile - Green Business Centre · Company Profile Energy Mapping & Energy Projects ... 1 Energy Saving by Arresting of Air-Leakage in HRD & Optiisation of Pressure 34.5 245.8

2018-19

Page 30: Company Profile - Green Business Centre · Company Profile Energy Mapping & Energy Projects ... 1 Energy Saving by Arresting of Air-Leakage in HRD & Optiisation of Pressure 34.5 245.8

1. Energy Management System – By Jan 2019▪ Energy Management system (EMS) installed in 2016 for trial basis in two section within the Plant▪ Online EMS System Electrical, Fuel and gas energy data of demand and supply side & system to be suitable

to ISO 50001 & PAT compliant reports

2. Implementation of ISO:50001 - ISO:50001 is under-implementation by Dec 2018

3. Power Quality & Harmonic Mitigation Study - This study will be done up to LT PCC Panel to avoid unwanted loss & to improve power reliability – By Nov 2018

4. Celebration of National Energy Conservation Day - National Energy Conservation Day, Dec 14th, is celebrated in JSHL every year to generate awareness among people▪ On this day, various events (Poster, Poem, Slogan) are organised and awards related to ‘Best Energy Saving

Area’, ‘Best Energy Saving Project’ and ‘Best Energy Manager’ are also distributed

5. Green Power - Promote use of Green Power by installation of Solar Power Plant, Solar Water Heater , composting plant & Bio-Gas Plant in plant premises

6. Training - Provided various internal & external training organized by CII/HAREDA/BEE on Energy Conservation in various topic i.e. Energy saving in Boilers, Compressor, Air-Conditioner, Green Building, Water Pump/Blower & solar system etc.

7. Energy Star Equipment - Installation of Energy Star Equipment i.e. AC, Fan & IE3 Motors in plant and investment as % of turn over to be increased.

PAT In progress