Top Banner
Communications Power Management Solutions
20

Communications Power Management Solutions

Oct 18, 2021

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Communications Power Management Solutions

Communications Power Management Solutions

Page 2: Communications Power Management Solutions

1

Make E-T-A yourDesign Partner

Power management solutions begin with an

understanding of your requirements. From

concept to production, E-T-A is equipped

with the expertise and tools necessary to de-

velop and produce a solution to meet the ex-

act specifications of your application regard-

less of the complexity.

Design

As your design partner, E-T-A adds circuit

protection expertise, electromechanical de-

sign and project management capabilities

to your team. This allows your design en-

gineers to maintain their focus on customer

and revenue critical applications while E-T-A

designs and supplies your power manage-

ment solutions.

Single Source Provider

E-T-A will streamline component sourcing

and vendor selection to reduce material and

inventory management requirements. E-T-

A’s efficient management and strong rela-

tionships with component vendors ensures

your power management systems will be

built with the best and most cost-effective

materials - giving your product offering the

competitive edge.

Manufacturing

Once the design is ap-

proved, E-T-A utilizes

state of the art equip-

ment, documented pro-

cesses and skilled labor

to build prototypes and

manufacture high vol-

ume orders. E-T-A’s

fully staffed manufac-

turing operation eliminates the need for you

to maintain and manage in-house manu-

facturing labor and eliminates the need for

manufacturing space for power management

systems.

Quality & Testing

Quality is E-T-A’s top priority. All power man-

agement solutions are manufactured and

100% tested in E-T-A’s ISO certified facility

prior to shipping. You

can be confident know-

ing the E-T-A power

management system

being integrated into

your equipment is built

and tested to the high-

est standards.

Page 3: Communications Power Management Solutions

Part number Description Pages

PDB-8340-0606-(XX) 1RU, Pluggable CBE 3 - 4

PDB-8345-0607-(XX) 1RU, Pluggable CBE 5 - 6

X1180R-S00-0500-1-240X00-(XX)-048X1180R-S00-0500-2-120X120-(XX)-048

1RU, Standard 19” 7 - 8

X8345R-S00-0584-2-03X30-(XX)-NA-058208X8345R-S00-0584-2-03X30-(XX)-E-058208

2RU, Pluggable CBE 9 - 10

X8345R-S00-0584-4-33X33-(XX)-NA-058208X8345R-S00-0584-4-33X33-(XX)-E-058208

2RU, Pluggable CBE 11 - 12

X452R-S00-0572-4-33X33-(XX)2RU, Pluggable CBE, Quick Connect

13 -14

X8340R-S00-0618-(XX) 2RU, Pluggable CBE 15 - 16

Breakers & System Accessories 17 - 18

StandardSystems

2

Page 4: Communications Power Management Solutions

PDB-8340-0606-(XX) 1RU, Pluggable CBE

Description

View

• Isolated A and B power regions for redundancy

• (2) PWR and (2) RTN inputs each side

• (6) PWR and (6) RTN outputs each side

• Inputs accept common 2-hole compression lugs up to 2 AWG

cable or 2-hole narrow tongue compression lugs up to 2/0 cable.

• Output accepts standard ring tongue terminals up to 10 AWG

cable, narrow tongue up to 8 AWG

• 1RU, Standard 19” rack mount chassis width, 8.25” chassis

depth

• Mounting flange options available for EIA 19”, 23” and ETSI

standard mounting

• Pluggable Circuit Breaker for field install or upgrade.

• E-T-A 8340 series, Hydraulic-Magnetic, UL1077 circuit

breakers (1A to 50A configurations avail. per channel)

• Voltage status indicator on each input

• LED on : Voltage live at system

• LED Green : Polarity Correct

• LED Red : Polarity Incorrect

• Options:

• Jumper Bar for reduced input configurations

• Alarm indicators and output

3

Page 5: Communications Power Management Solutions

Schematic diagram

Technical Data

Standard Part Numbers

Part Number Supply Feeds Breakers per feed Rack mount size Operating Voltage Current Carrying Capacity

PDB-8340-0606-19

4 3

19”- 72 VDC

to72 VDC

300 APDB-8340-0606-23 23”

PDB-8340-0606-ETSI ETSI

Dimensions 17.50” x 1.75” x 8.70”

Rack Mounting 19”, ETSI, 23” & Custom

Operating Voltage -72 VDC to 72 VDC

Operating Temperature - 5° C to 55° C

Current Carrying Capacity 300 A

Breaker Capacity 12 channels, 50 A max per channel

Circuit Protection/Control Hydraulic Magnetic - Single Pole

Circuit Breaker 8340-G110-R1H1-A7H0-xxA

Input Terminals 2-hole lug, 1/4”-20 studs, 5/8” offset

Output Terminals #8-32 screw terminal, Phillips

Chassis Ground 2-hole lug, 1/4”-20 studs, 5/8” offset

Hardware 1/4” kep nuts, #8 screws (included)

RoHs Status Compliant

Approvals • UL, CSA, CB Scheme Pending

• Designed to meet NEBs Level 3

4

Page 6: Communications Power Management Solutions

PDB-8345-0607-(XX)1RU, Pluggable CBE

Description

View

• Isolated A and B power regions for redundancy

• (2) PWR and (2) RTN inputs each side

• (2) PWR and (2) RTN outputs each side

• Inputs and Outputs accept common 2-hole compression lugs up

to 2 AWG cable or 2-hole narrow tongue compression lugs up to

2/0 cable.

• 1RU, Standard 19” rack mount chassis width, 8.25” chassis

depth

• Mounting flange options available for EIA 19”, 23” and ETSI

standard mounting

• Pluggable Circuit Breaker for field install or upgrade.

• E-T-A 8345 series, Hydraulic-Magnetic, UL489 circuit

breakers (1A to 125A configurations avail.)

• Voltage status indicator for each input

• LED on : Voltage live at system

• LED Green : Polarity Correct

• LED Red : Polarity Incorrect

• Options:

• Jumper bar for reduced input configuration

• Alarm indicators and output

5

Page 7: Communications Power Management Solutions

Schematic diagram

Technical Data

Dimensions 17.50” x 1.75” x 8.23”

Rack Mounting 19”, ETSI, 23” & Custom

Operating Voltage -72VDC to 72VDC

Operating Temperature -5°C to 55°C

Current Carrying Capacity 250 A

Breaker Capacity 4 channels, 125 A max. per channel

Circuit Protection/Control Hydraulic Magnetic - Single Pole

Circuit Breaker

Switch

8345-F01Z-R0M1-DB1B2B-(1-125A)

8345-F01Z-R0M1-DB1B1B-125A

Input Terminals 2-hole lug, 1/4”-20 studs, 5/8” offset

Output Terminals 2-hole lug, 1/4”-20 studs, 5/8” offset

Chassis Ground 2-hole lug, 1/4”-20 studs, 5/8” offset

Hardware 1/4” Kep Nuts (Included)

RoHs Status Compliant

Approvals • UL, CSA, CB Scheme Pending

• Designed to meet NEBs Level 3

Standard Part Numbers

Part Number Supply Feeds Breakers per feed Rack mount size Operating Voltage Current Carrying Capacity

PDB-8345-0607-19

4 1

19”-72VDC

to72VDC

250 APDB-8345-0607-23 23”

PDB-8345-0607-ETSI ESTI

6

Page 8: Communications Power Management Solutions

X1180R-S00-05421RU, Standard 19”

Description

View

• Isolated A and B power regions for redundancy

• (1) PWR and (1) RTN inputs each side

• (12) PWR and (12) RTN outputs each side

• Inputs accept common 2-hole compression lugs up to 2/0 cable.

• Output accepts bare wire – 20 to 12 AWG cable

• 1RU, Standard 19” rack mount chassis width, 9.14” chassis

depth

• Mounting flange options available for EIA 19”, 23” and ETSI

standard mounting

• Pluggable Circuit Breaker for field install or upgrade.

• E-T-A 1180 series, Thermal CBE, UL1077 circuit breakers

(0.1A to 10A configurations avail.)

7

Page 9: Communications Power Management Solutions

Schematic diagram

Technical Data

Module 1

IN 1

Module 2

OUT 1CB 1

CB 2

CB 3

CB12

CB 1

CB 2

CB 3

CB12

OUT 2

OUT 3

OUT 12

OUT 1

OUT 2

OUT 3

OUT 12

Module 1 Module 2

IN 1

OUT 1CB 1

CB 2

CB12

CB 1

CB 2

CB 3

CB12

OUT 2

OUT 12

OUT 1

OUT 2

OUT 3

OUT 12

CB 3 OUT 3

IN 1

Standard Part Numbers

Part Number Supply Feeds Breakers per feed Rack mount size Operating Voltage Current Carrying Capacity

X1180R-S00-0542-1-240X00-19-0481 24

19”

- 72 VDCto

72 VDC

120AX1180R-S00-0542-1-240X00-23-048 23”

X1180R-S00-0542-2-120X120-19-0482 12 + 12

19”240A

X1180R-S00-0542-2-120X120-23-048 23”

X1180R... 00X240 X1180R... 120X120

Dimensions 17.50” x 1.75” x 9.14”

Rack Mounting 19”, 23”, ETSI & Custom

Operating Voltage - 72 VDC to 72 VDC

Operating Temperature - 5° C to - 55° C

Current Carrying Capacity 240A

Breaker Capacity 24 channels , 10 A max per channel

Circuit Protection/Control Thermal - Single Pole

Circuit Breaker 1180-01-(0.1 - 10A)

Input Terminals 2-hole lug, M6 studs, 5/8” offset

Output Terminals Screw terminal - bare wire termination

Chassis Ground 2-hole lug, M6 studs, 5/8” offset

RoHs Status Compliant

Approvals • UL

• CSA

• CB

• Designed to meet NEBs Level 3

8

Page 10: Communications Power Management Solutions

X8345R-S00-0584-2-03X30-(XX)-(X)-058208;2RU, Pluggable CBE

Description

View

• Isolated A and B power regions for redundancy

• (1) PWR and (1) RTN inputs each side

• (3) PWR and (3) RTN outputs each side

• Inputs accept common 2-hole compression lugs up to 2/0 cable

• Outputs accept common 2-hole compression lugs up to 2 AWG

cable

• Rear and Side cable access

• 2RU, Standard 19” rack mount chassis width, 8.25” chassis

depth

• Mounting flange options available for EIA 19”, 23” and ETSI

standard mounting

• Pluggable circuit breaker for field instalation or upgrade

• E-T-A 8345 series, Hydraulic-Magnetic,UL489 circuit

breakers (1A to 125A configurations avail.)

• Option:

• Slide rail kit available for ETSI and 23” version

9

Page 11: Communications Power Management Solutions

Technical Data

Standard Part Numbers

Dimensions 17.50” x 3.50” x 11.10”

Rack Mounting 19”, ETSI, 23” & Custom

Operating Voltage -72VDC to 72VDC

Operating Temperature -5°C to 52°C

Current Carrying Capacity 240A @ 52°C / 250A @ 42°C

Breaker Capacity 6 channels - 80A per channel @ 52°C90A per channel @ 42°C

Circuit Protection/Control Hydraulic Magnetic - Single Pole

Circuit Breaker

Switch

8345-F01Z-R0M1-DB1B2B-(1-90A)

8345-F01Z-R0M1-DB1B1B-125A

Input Terminals 2-hole lug, M6 studs, 5/8” offset

Output Terminals 2-hole lug, M6 studs, 5/8” offset

Chassis Ground 2-hole lug, M6 studs, 5/8” offset

Hardware Included M6 Kep Nuts (Included)

RoHs Status Compliant

Approvals • UL Listed

• CSA

• CB

• Designed to meet NEBs Level 3

Part Number Supply Feeds Breakers per feed Rack mount size Operating VoltageCurrent Carrying

Capacity

X8345R-S00-0584-2-03x30-19-NA-058208

2 3

19”

-72VDCto

72VDC250A

X8345R-S00-0584-2-03x30-ETSI-NA-058208 ETSI

X8345R-S00-0584-2-03x30-23-NA-058208 23”

X8345R-S00-0584-2-03x30-19-E-058208 19”

X8345R-S00-0584-2-03x30-ETSI-E-058208 ETSI

X8345R-S00-0584-2-03x30-23-E-058208 23”

10

Schematic diagram

X8345R-S00-0584-2-03x30-xx-NA-058208

X8345R-S00-0584-2-03x30-xx-E-058208

Page 12: Communications Power Management Solutions

X8345R-S00-0584-4-33X33-(XX)-(X)-058208;2RU, Pluggable CBE

Description

View

• Isolated A and B power regions for redundancy

• (2) PWR and (2) RTN inputs each side

• (6) PWR and (6) RTN outputs each side

• Inputs accept common 2-hole compression lugs up to 2/0 cable

• Outputs accept common 2-hole compression lugs up to 2 AWG

cable

• Rear and Side cable access

• 1RU, Standard 19” rack mount chassis width, 8.25” chassis depth

• Mounting flange options available for EIA 19”, 23” and ETSI standard

mounting

• Pluggable circuit breaker for field install or upgrade

• E-T-A 8345 series, Hydraulic-Magnetic,UL489 circuit breakers

(1A to 125A configurations avail.)

• Options:

• Slide rail kit available for ETSI and 23” version

• Jumper bar for reduced input configruation

11

Page 13: Communications Power Management Solutions

Schematic diagram

Technical Data

Standard Part Numbers

Dimensions 17.50” x 3.50” x 11.10”

Rack Mounting 19”, ETSI, 23” & Custom

Operating Voltage -72VDC to 72VDC

Operating Temperature -5°C to 42°C

Current Carrying Capacity 500A

Breaker Capacity 12 channels, 90A max. per channel

Circuit Protection/Control Hydraulic Magnetic - Single Pole

Circuit Breaker

Switch

8345-F01Z-R0M1-DB1B2B-(1-90A)

8345-F01Z-R0M1-DB1B1B-90A

Input Terminals 2-hole lug, M6 studs, 5/8” offset

Output Terminals 2-hole lug, M6 studs, 5/8” offset

Chassis Ground 2-hole lug, M6 studs, 5/8” offset

Hardware M6 Kep Nuts (Included)

RoHs Status Compliant

Approvals • UL Listed

• CSA

• CB Scheme

• Designed to meet NEBs Level 3

Part Number Supply Feeds Breakers per feed Rack mount size Operating VoltageCurrent Carrying

Capacity

X8345R-S00-0584-4-33X33-19-NA-058208

4 3

19”

-72VDCto

72VDC500A

X8345R-S00-0584-4-33X33-ETSI-NA-058208 ESTI

X8345R-S00-0584-4-33X33-23-NA-058208 23”

X8345R-S00-0584-4-33X33-19-E-058208 19”

X8345R-S00-0584-4-33X33-ETSI-E-058208 ESTI

X8345R-S00-0584-4-33X33-23-E-058208 23”

X8345R-S00-0584-4-33X33-xx-NA-058208

X8345R-S00-0584-4-33X33-xx-E-058208

12

INPUTB1

A1

A2

INPUTA1

OUTPUTA1

-BATT

+RTN

-BATT

+RTN

OUTPUTA2

A4

A5

INPUTA2

A3OUTPUT

A3

A6

OUTPUTA4

OUTPUTA5

OUTPUTA6

B1

B2

OUTPUTB1

OUTPUTB2

B4

B5

INPUTB2

B3OUTPUT

B3

B6

OUTPUTB4

OUTPUTB5

OUTPUTB6

+RTN

-BATT

+RTN

-BATT

+RTN

-BATT

+RTN

-BATT

+RTN

-BATT

-BATT

+RTN

-BATT

+RTN

-BATT

+RTN

-BATT

+RTN

+RTN

-BATT

+RTN

-BATT

+RTN

-BATT

+RTN

-BATT

+RTN

-BATT

INPUTB1

A1

A2

INPUTA1

OUTPUTA1

-BATT

+RTN

-BATT

+RTN

OUTPUTA2

A4

A5

INPUTA2

A3OUTPUT

A3

A6

OUTPUTA4

OUTPUTA5

OUTPUTA6

B1

B2

OUTPUTB1

OUTPUTB2

B4

B5

INPUTB2

B3OUTPUT

B3

B6

OUTPUTB4

OUTPUTB5

OUTPUTB6

+RTN

-BATT

+RTN

-BATT

+RTN

-BATT

+RTN

-BATT

+RTN

-BATT

-BATT

+RTN

-BATT

+RTN

-BATT

+RTN

-BATT

+RTN

+RTN

-BATT

+RTN

-BATT

+RTN

-BATT

+RTN

-BATT

+RTN

-BATT

Page 14: Communications Power Management Solutions

X452-S00-0572-4-33X33-(XX)2RU, Pluggable CBE, Quick Connect

Description

View

• Isolated A and B power regions for redundancy

• (2) PWR and (2) RTN inputs each side

• (6) PWR and (6) RTN outputs each side

• Inputs accept common 2-hole compression lugs up to 1/0 or 2-hole

flex lug up to 1 AWG

• Outputs accept Anderson PP75 quick connects

• 2 RU standard 19” rack mount chassis width, 9.75” chassis depth

• Mounting flange options available for EIA 19”, 23” and ETSI standard

mounting

• Pluggable circuit breaker for field install or upgrade

• E-T-A 8340 series, Hydraulic-Magnetic, UL 1077 circuit breakers

(1 - 50A configurations available per channel)

• E-T-A 452 series, Thermal-Magnetic, UL 1077 circuit breakers

(1 - 125A configurations availbale per channel)

13

Page 15: Communications Power Management Solutions

Schematic diagram

Technical Data

Dimensions 17.50” x 3.50” x 9.25”

Rack Mounting 19”, ETSI, 23” & Custom

Operating Voltage -72 VDC to 72 VDC

Operating Temperature - 5°C to 55°C

Current Carrying Capacity 450A

Breaker Capacity 12 channels, 75A max per channel

Circuit Protection/Control Thermal Magnetic - Single Pole

Hydraulic Magnetic - Single Pole

Circuit Breaker

Circuit Breaker

8340-G110-R1H1-A7H0-xxA

452-R1LN2-xxA

Standard Part Numbers

Part Number Supply Feeds Breakers per feed Rack mount size Operating Voltage Current Carrying Capacity

X452R-S00-0572-19

4 3

19”- 72 VDC

to72 VDC

450AX452R-S00-0572-ETSI ETSI”

X452R-S00-0572-23 23”

Input Terminals 2-hole lug, 1/4”-20 studs, 5/8” offset

Output Terminals Anderson PP75

Chassis Ground 2-hole lug, 1/4”-20 studs, 5/8” offset

Hardware 1/4” kep nuts (included)

RoHs Status Compliant

Approvals • UL, CSA, CB Scheme Pending

• Designed to meet NEBs Level 3

14

Page 16: Communications Power Management Solutions

Description

View

• Isolated A and B power regions for redundancy

• (2) PWR and (2) RTN inputs each side

• (6) PWR and (6) RTN outputs each side

• Inputs accept common 2-hole compression lugs up to 2 AWG

cable or 2-hole narrow tongue compression lugs up to 2/0 cable.

• Output accepts standard ring tongue terminal s up to 10 AWG

cable, narrow tongue up to 8 AWG

• 1RU, Standard 19” rack mount chassis width, 8.25” chassis

depth

• Mounting flange options available for EIA 19”, 23” and ETSI

standard mounting

• Pluggable Circuit Breaker for field install or upgrade.

• E-T-A 8340 series, Hydraulic-Magnetic, UL1077 circuit

breakers (1A to 50A configurations avail. per channel)

• Voltage status indicator on each input

• LED on : Voltage live at system

• LED Green : Polarity Correct

• LED Red : Polarity Incorrect

• Options:

• Jumper bar for reduced Input configurations

• Alarm indicators and output

X8340R-S00-0618-(XX)2RU, Pluggable CBE

15

Page 17: Communications Power Management Solutions

Schematic diagram

Technical Data

Standard Part Numbers

Part Number Supply Feeds Breakers per feed Rack mount size Operating Voltage Current Carrying Capacity

X8340R-S00-0618-19

4 3

19”- 72 VDC

to72 VDC

300AX8340R-S00-0618-ETSI ETSI

X8340R-S00-0618-23 23”

Dimensions 17.50” x 3.50” x 9.50”

Rack Mounting 19”, ETSI, 23” & Custom

Operating Voltage -72 VDC to 72 VDC

Operating Temperature - 5° C to 55° C

Current Carrying Capacity 300 A

Breaker Capacity 12 channels, 50 A max per channel

Circuit Protection/Control Hydraulic Magnetic - Single Pole

Circuit Breaker 8340-G110-R1H1-A7H0-xxA

Input Terminals 2-hole lug, 1/4”-20 studs, 5/8” offset

Output Terminals #8-32 screw terminals, Phillips

Chassis Ground 2-hole lug, 1/4”-20 studs, 5/8” offset

Hardware 1/4” kep nuts, #8 screws (included)

RoHs Status Compliant

Approvals • UL Listed

• CSA

• CB Scheme

• Designed to meet NEBs Level 3

PWRA1-1

A1-2

OUTPUTA1-1

OUTPUTA1-2

A1-3OUTPUT

A1-3

-BATT -BATT+RTN

+RTN-BATT

+RTN-BATT

INPUT A1

PWRA2-4

A2-5

OUTPUTA2-4

OUTPUTA2-5

A2-6OUTPUT

A2-6

-BATT -BATT+RTN

+RTN-BATT

+RTN-BATT

INPUT A2

+RTN

A-SIDE

RTN+RTN

RTN

PWRB1-1

B1-2

OUTPUTB1-1

OUTPUTB1-2

B1-3OUTPUT

B1-3

-BATT -BATT+RTN

+RTN-BATT

+RTN-BATT

INPUT B1

PWRB2-4

B2-5

OUTPUTB2-4

OUTPUTB2-5

B2-6OUTPUT

B2-6

-BATT -BATT+RTN

+RTN-BATT

+RTN-BATT

INPUT B2

+RTN

B-SIDE

RTN+RTN

RTN

VOLTAGE MONITOR

INPUT A1 STATUSINPUT A2 STATUS

VOLTAGE MONITOR

INPUT B1 STATUSINPUT B2 STATUS

16

Page 18: Communications Power Management Solutions

Circuit BreakerTechnical Information

DescriptionMiniturized single pole thermal cir-cuit breaker with switching function optional (push-push actuation)

Thermal-magnetic, threadneck panel mounting, push/pull opera-tion, with auxiliary contact option

Voltage Rating250 VAC; 65 VDC *(*UL, UL Canada: 250 VAC; 72 VDC)

28 VDC

Current Ratings 0.1... 10A 50... 100A

Typical Life/ Contact Rating6,000 operations at 1 x IN, resistive3,000 operations at 1 x IN, inductive500 operations at 2 x IN, inductive

2500 operations at 1 x IN

Interrupting Capacity Icn 0.1... 5A 6 x IN6... 10A 8 x IN

28 VDC; 6000A115 VAC (400 Hz); 1500A

Approvals UL, UL Candad, VDEUL, VG 95345 part 17, QPL Canada, QPL Sweeden

Dimensions

Internal Connection Diagrams

1180 452

line 1

2

I >

1

2

1.9

1.5

48.6

ON

48.8

52.3

OFF

24.4.961

.780

.075

.059

1.91

1.92

17

Page 19: Communications Power Management Solutions

Thermal, single-pole, threadneck panel mounting, push/pull opera-tion, with auxiliary contact option

Push/pull circuit breaker, thread-neck panel mounting, with auxiliary option. UL 489 A approval

Toggle circuit breaker, flange mounting, with auxiliary contact option and UL 489 approval

115 VAC (400 Hz), 28 VDC** UL: 72 VDC

3 AC 415 V;240 VAC * (50/60 Hz); 80 VDC* UL, CSA: 250 VAC

80 VDC; 240 VAC;AC 120/240 V; AC 277/480 V;2 AC 415 V

0.1...50A0.02... 50 A single pole0.02... 30 A multipole(UL: 0.02... 50 A multipole)

0.05... 125 AHigher ratings available upon request

10,000 operations, mechanical5,000 operations at 1 x IN

10,000 operations with1 x IN, resistive 1 pole5,000 operations with 1 x IN, resis-tive 2 pole

10,000 operations with 1 x IN

0.1...2.5 A 15 x IN3...3.5A 250 A DC/100 A AC4...7A 500 A7.5...50 A 6,000 A DC/ 1,000 A AC35...50 A 3,000 A DC/ 1,000 A AC

AC: 1,200 ADC: 2,000 A

AC: 5,000 ADC: 10,000 A

UL, CSA, QPL Canada, VG 95345 T21

UL, CSA, VDE, CCC UL, VDE

482 8340 8345

2

line 1

line 1 11 23

12 24

2(k) load

I >

line 1 11(C)

2 (load)

I > 14(NO)12(NC)

12.2

O

FF ON M12x1

6

max

. 6.3

5

42.2

22

19.6

.866

.772

1.66max

.250

.480

.236

1.5

.059

6.5

57.5

.256

2.26

ON

12.5

M12x1

18.2

.492

OFF

1.5

.059

.717

1 11 23 2(i) 24 12 2( k)

19.5

34

22.5

61.34

.768 .886

.236

ENILDAOL

49.21.94

1.94

.756

49.2

19.2

18

Page 20: Communications Power Management Solutions

E-T-A Circuit Breakers 1551 Bishop Ct.Mt. Prospect, IL 60056Phone (847) 827-7600 Fax (847) [email protected]