Top Banner
AMERICAN AIR & WATER ® , INC. American Air & Water®, Inc. * 12 Gibson Drive * Hilton Head Island, SC 29926 Phone: 843-785-8699 * 888-378-4892 * Fax: 843-785-2064 * www.americanairandwater.com Prices subject to change without notice. All cancelled orders are subject to a 30% restocking fee. Past due invoices are subject to a 1.5% per month interest fee. 1 Sep12 Commercial UV Systems Table of Contents Table of Contents UV AIR CLEANERS, SURFACE STERILIZERS AND REPLACEMENT UV LAMPS SPECS & PRICES CC High Output UV Coil Cleaners DC High Output Duct Cleaners NC High Output UV Air Cleaners SM Surface Mounted Fixtures UF Utility Fixtures CE Closed End Reflector Fixtures TB & CM In-Room Fixtures RT Recessed Troffers & DB Door Barriers UV Lamps Cold Cathode & Hot Cathode UV Lamps Slimline & High Output UV Lamps LTC, SC, LTX, STX, LTB, STG, TTG Sterile Conditioners Replacement Parts for UV Sterile Conditioners UV Safety Equipment, UV Monitors, Quartz Sleeves and Blacklight lamps Sporicidin Disinfectant and Sterilizing Solution Fogger and Sprayer GERMICIDAL UV LIGHT – GENERAL INFORMATION AND FORMULAS Determining UV Intensities using germicidal UV lamps (Intensity factor) Distribution of Radiant UV Energy, UV Reflective Factors, UV Extinction Depths
40

Commercial UV Products - American Air & Water, Inc Surface Mounted Fixtures UF Utility Fixtures CE Closed End Reflector Fixtures TB & CM In-Room Fixtures RT Recessed Troffers & DB

Mar 21, 2018

Download

Documents

vannguyet
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Commercial UV Products - American Air & Water, Inc Surface Mounted Fixtures UF Utility Fixtures CE Closed End Reflector Fixtures TB & CM In-Room Fixtures RT Recessed Troffers & DB

AMERICAN AIR & WATER®, INC.

American Air & Water®, Inc. * 12 Gibson Drive * Hilton Head Island, SC 29926 Phone: 843-785-8699 * 888-378-4892 * Fax: 843-785-2064 * www.americanairandwater.com

Prices subject to change without notice. All cancelled orders are subject to a 30% restocking fee. Past due invoices are subject to a 1.5% per month interest fee.

1Sep12

Commercial UV Systems

Table of Contents

Table of Contents

UV AIR CLEANERS, SURFACE STERILIZERS AND REPLACEMENT UV LAMPS SPECS & PRICES

CC High Output UV Coil Cleaners

DC High Output Duct Cleaners

NC High Output UV Air Cleaners

SM Surface Mounted Fixtures

UF Utility Fixtures

CE Closed End Reflector Fixtures

TB & CM In-Room Fixtures

RT Recessed Troffers & DB Door Barriers

UV Lamps

Cold Cathode & Hot Cathode UV Lamps

Slimline & High Output UV Lamps

LTC, SC, LTX, STX, LTB, STG, TTG Sterile Conditioners

Replacement Parts for UV Sterile Conditioners

UV Safety Equipment, UV Monitors, Quartz Sleeves and Blacklight lamps

Sporicidin Disinfectant and Sterilizing Solution

Fogger and Sprayer

GERMICIDAL UV LIGHT – GENERAL INFORMATION AND FORMULAS

Determining UV Intensities using germicidal UV lamps (Intensity factor)

Distribution of Radiant UV Energy, UV Reflective Factors, UV Extinction Depths

Page 2: Commercial UV Products - American Air & Water, Inc Surface Mounted Fixtures UF Utility Fixtures CE Closed End Reflector Fixtures TB & CM In-Room Fixtures RT Recessed Troffers & DB

AMERICAN AIR & WATER®, INC.

American Air & Water®, Inc. * 12 Gibson Drive * Hilton Head Island, SC 29926 Phone: 843-785-8699 * 888-378-4892 * Fax: 843-785-2064 * www.americanairandwater.com

Prices subject to change without notice. All cancelled orders are subject to a 30% restocking fee. Past due invoices are subject to a 1.5% per month interest fee.

2Sep12

CC HIGH OUTPUT UV COIL CLEANERS

CC Series High-Output UV systems are designed specifically for HVAC applications. They can be mounted in various configurations to irradiate cooling coils and drain pans and for optimum pass-by air decontamination. Individual fixtures can be mounted to plenum walls or multiple fixtures can mount to frame assemblies that span supply ducts or cooling coils. This type of UVC fixtures has been incorporated in the Facilities Standards for the Public Buildings by the U.S. General Services Administration Office of the Chief Architect Applications: Coil Clean (CC) Series UV fixtures are ideal for internal installation in medium to large HVAC systems in commercial, industrial, health care and institutional buildings. They are an excellent choice for mounting close to the coil and drain pan areas to inhibit the growth of mold and mildew in these areas. The CC UV Systems are moisture proof and are offered in single and double lamp configurations. They can be mounted individually or in built-up banks, or in parallel rack-system configurations in a variety of locations, including coils, drain pans, ductwork, mixed air plenums and exhaust systems. The CC fixtures are available in 18”, 24”, 36”, 48” and 60” lengths and 115, 208, 230 or 277VAC voltage options, providing installation flexibility to accommodate virtually any HVAC system. The CC fixtures are designed for moisture-proof applications with UVC lamps that incorporate a built-in outer quartz sleeve with protective boot on the power end for sealing purposes. Power is brought to the lamp with coated lead wires through a waterproof connector that is securely sealed to the lamp. The UV lamps are rated for two-year continuous operational life with approximately 20% drop in UVC output at end of lamp life. Features and Benefits of CC germicidal UV systems installation:

Improves Indoor Air Quality (IAQ) by reducing bacteria, viruses, mold and spores that either grow or pass through the air handling systems. Reduces the risk of cold, flu, allergies and other illness associated with air handling systems

“Green” lamps contain ≤8mg of mercury Two-year (17,000 hours) guarantee on lamps with only 20% decrease in UV

output over the two years Five-year, non-prorated warranty on the ballast Continuously cleans coils, drain pans, plenums and ducts - eliminating costly

cleaning programs and the use of harmful chemicals and disinfectants Reduces HVAC energy costs by restoring heat transfer and net cooling

capacity Produces no ozone or any other secondary contaminants Plug-in connections mean no field wiring required to connect fixture to fixture

when building banks of rack systems SPECIFICATIONS: Every CC Series fixture is manufactured and factory assembled in the USA and tested prior to shipment. Each assembly consists of housing, reflector, electronic ballast(s), lamp bracket, plug-in power connectors and high output lamp(s). FIXTURE: Housings are constructed of heavy gauge hospital grade stainless steel. Reflectors are fabricated from the highest grade bright annealed polished stainless steel, which has a reflectivity rate of 88% when exposed to short-wave UVC in the range of 254 nm. All components are in one integrated assembly to maximize serviceability.

Water-tight lamp connection

Connect multiple fixtures toone power source

Hardwire fixtures are also available

Page 3: Commercial UV Products - American Air & Water, Inc Surface Mounted Fixtures UF Utility Fixtures CE Closed End Reflector Fixtures TB & CM In-Room Fixtures RT Recessed Troffers & DB

AMERICAN AIR & WATER®, INC.

American Air & Water®, Inc. * 12 Gibson Drive * Hilton Head Island, SC 29926 Phone: 843-785-8699 * 888-378-4892 * Fax: 843-785-2064 * www.americanairandwater.com

Prices subject to change without notice. All cancelled orders are subject to a 30% restocking fee. Past due invoices are subject to a 1.5% per month interest fee.

3Sep12

BALLAST: The solid-state electronic ballast (furnished with this series), is a Class P rapid start with a power factor minimum of .95. It is available for 120, 208, 230, or 277VAC 50/60Hz and is designed to maximize photon production in air temperatures of 35º to 175º F. Minimum ballast start temperature is minus 20º F. Ballasts have an RFI - EMI rating as defined by FCC part 18A for industrial / commercial applications in regards to suppression. Ballasts are UL listed and suitable for use in air handling spaces. LAMPS: CC Series UVC lamps are high-output (800mA), T5 tube diameter, and constructed from hard glass tubing for superior UV transmittance. Lamps are “green”, containing ≤8mg of mercury (Hg) and they produce no ozone. Lamps shall retain, at minimum, 80% of initial output after 17,000 hours of use. They are sealed for moisture protection with a water-tight connection. Electrodes are designed to maximize plasma convection and stability for superior lamp performance. Lamps are rated to produce 11.7µW/cm² per linear inch of lamp arc length at 1m in airstreams of 400FPM velocities at temperatures of 45º F. INDEPENDENT TESTING: Units are tested in accordance with the general provisions of IES Lighting Handbook, 1981 Applications Volume, and provide output per 1" arc length of not less than 11.7µW/cm² at 1m in a 400FPM airstream of 45° F.

CC Series Fixture Offerings

120VAC, 50/60Hz 208/230VAC, 50/60Hz 277VAC, 50/60Hz

2-LAMP UNITS End-to-End Plug-in Hardwire End-to-End

Plug-in Hardwire Hardwire

18" CC18-2-120C CC18-2-120 CC18-2-230C CC18-2-230 CC18-2-277

24" CC24-2-120C CC24-2-120 CC24-2-230C CC24-2-230 CC24-2-277

36" CC36-2-120C CC36-2-120 CC36-2-230C CC36-2-230 CC36-2-277

48" CC48-2-120C CC48-2-120 CC48-2-230C CC48-2-230 CC48-2-277

Fixt

ure

Leng

th

60" CC60-2-120C CC60-2-120 CC60-2-230C CC60-2-230 CC60-2-277

1-LAMP UNITS

18" CC18-1-120C CC18-1-120 CC18-1-230C CC18-1-230 CC18-1-277

24" CC24-1-120C CC24-1-120 CC24-1-230C CC24-1-230 CC24-1-277

36" CC36-1-120C CC36-1-120 CC36-1-230C CC36-1-230 CC36-1-277

48" CC48-1-120C CC48-1-120 CC48-1-230C CC48-1-230 CC48-1-277

Fixt

ure

Leng

th

60" CC60-1-120C CC60-1-120 CC60-1-230C CC60-1-230 CC60-1-277 All CC Fixtures are 3.07" wide and 5.2" deep (including lamps). End-to-End Plug-in units require one (1) female junction box and one end cover per row; Junction Box 2540-15B, End Cover 2540-18. Amperage draw provided on submittal drawings. Cord kits available for 120V units to plug into standard 120V receptacle.

Technical Data

Models Lamp Model UVC Watts UVC Intensity * µW/cm² @1m

Coil Coverage /Sq. Ft./

CC18-1 GCL 18 10 175 2 CC18-2 GCL 18 (2) 20 350 4 CC24-1 GCL 24 16.2 245 3 CC24-2 GCL 24 (2) 32.4 490 6 CC36-1 GCL 36 25 386 5 CC36-2 GCL 36 (2) 50 772 10 CC48-1 GCL 48 36.1 526 7 CC48-2 GCL 48 (2) 72.2 1,052 14 CC60-1 GCL 60 46 667 10 CC60-2 GCL 60 (2) 92 1,334 19

* Units are tested in accordance with the general provisions of IES Lighting Handbook, 1981 Applications Volume in a 400FPM airstream, at 45° F.

Page 4: Commercial UV Products - American Air & Water, Inc Surface Mounted Fixtures UF Utility Fixtures CE Closed End Reflector Fixtures TB & CM In-Room Fixtures RT Recessed Troffers & DB

AMERICAN AIR & WATER®, INC.

American Air & Water®, Inc. * 12 Gibson Drive * Hilton Head Island, SC 29926 Phone: 843-785-8699 * 888-378-4892 * Fax: 843-785-2064 * www.americanairandwater.com

Prices subject to change without notice. All cancelled orders are subject to a 30% restocking fee. Past due invoices are subject to a 1.5% per month interest fee.

4Sep12

CC HIGH OUTPUT UV COIL CLEANERS - PRICES

The CC High Output UV systems are designed for general-purpose air and surface disinfection of cooling coils and drip pans inside large AHUs. Constructed of high grade stainless steel with moisture proof connections for installation downstream of cooling colis. Germicidal energy at 254nm is effective for 17,000 hours. Lamps should be replaced before the end of effective life. Clean, monitor and check lamps regularly. Model Description CC18-1-120 CC18-1-230 CC18-1-277

120V, 18", Single lamp fixture, hardwire connection 208/230V, 18", Single lamp fixture, hardwire connection 277V, 18", Single lamp fixture, hardwire connection

CC18-1-120C CC18-1-230C

120V, 18", Single lamp fixture, "Power Port" connection 208/230V, 18", Single lamp fixture, "Power Port" connection One junction box and one end cap required per row

CC18-2-120 CC18-2-230 CC18-2-277

120V, 18", 2 lamp fixture, hardwire connection 208/230V, 18", 2 lamp fixture, hardwire connection 277V, 18", 2 lamp fixture, hardwire connection

CC18-2-120C CC18-2-230C

120V, 18", 2 lamp fixture, "Power Port" connection 208/230V, 18", 2 lamp fixture, "Power Port" connection One junction box and one end cap required per row

GCL-18 Lamp for all CC18 Fixtures CC24-1-120 CC24-1-230 CC24-1-277

120V, 24", Single lamp fixture, hardwire connection 208/230V, 24", Single lamp fixture, hardwire connection 277V, 24", Single lamp fixture, hardwire connection

CC24-1-120C CC24-1-230C

120V, 24", Single lamp fixture, "Power Port" connection 208/230V, 24", Single lamp fixture, "Power Port" connection One junction box and one end cap required per row

CC24-2-120 CC24-2-230 CC24-2-277

120V, 24", 2 lamp fixture, hardwire connection 208/230V, 24", 2 lamp fixture, hardwire connection 277V, 24", 2 lamp fixture, hardwire connection

CC24-2-120C CC24-2-230C

120V, 24", 2 lamp fixture, "Power Port" connection 208/230V, 24", 2 lamp fixture, "Power Port" connection One junction box and one end cap required per row

GCL-24 Lamp for all CC24 Fixtures CC36-1-120 CC36-1-230 CC36-1-277

120V, 36", Single lamp fixture, hardwire connection 208/230V, 36", Single lamp fixture, hardwire connection 277V, 36", Single lamp fixture, hardwire connection

CC36-1-120C CC36-1-230C

120V, 36" Single lamp fixture, "Power Port" connection 208/230V, 36" Single lamp fixture, "Power Port" connection One junction box and one end cap required per row

CC36-2-120C CC36-2-230C CC36-2-277

120V, 36", 2 lamp fixture, hardwire connection 208/230V, 36", 2 lamp fixture, hardwire connection 277V, 36", 2 lamp fixture, hardwire connection

CC36-2-120C CC36-2-230C

120V, 36", 2 lamp fixture, "Power Port" connection 208/230V, 36", 2 lamp fixture, "Power Port" connection One junction box and one end cap required per row

GCL-36 Lamp for all CC36 Fixtures CC48-1-120 CC48-1-230 CC48-1-277

120V, 48", Single lamp fixture, hardwire connection 208/230V, 48", Single lamp fixture, hardwire connection 277V, 48", Single lamp fixture, hardwire connection

CC48-1-120C CC48-1-230C

120V, 48" Single lamp fixture, "Power Port" connection 208/230V, 48" Single lamp fixture, "Power Port" connection One junction box and one end cap required per row

Continued on next page

Page 5: Commercial UV Products - American Air & Water, Inc Surface Mounted Fixtures UF Utility Fixtures CE Closed End Reflector Fixtures TB & CM In-Room Fixtures RT Recessed Troffers & DB

AMERICAN AIR & WATER®, INC.

American Air & Water®, Inc. * 12 Gibson Drive * Hilton Head Island, SC 29926 Phone: 843-785-8699 * 888-378-4892 * Fax: 843-785-2064 * www.americanairandwater.com

Prices subject to change without notice. All cancelled orders are subject to a 30% restocking fee. Past due invoices are subject to a 1.5% per month interest fee.

5Sep12

CC48-2-120 CC48-2-230 CC48-2-277

120V, 48", 2 lamp fixture, hardwire connection 208/230V, 48", 2 lamp fixture, hardwire connection 277V, 48", 2 lamp fixture, hardwire connection

CC48-2-120C CC48-2-230C

120V, 48", 2 lamp fixture, "Power Port" connection 208/230V, 48", 2 lamp fixture, "Power Port" connection One junction box and one end cap required per row

GCL-48 Lamp for all CC48 Fixtures CC60-1-120 CC60-1-230 CC60-1-277

120V, 60", Single lamp fixture, hardwire connection 208/230V, 60", Single lamp fixture, hardwire connection 277V, 60", Single lamp fixture, hardwire connection

CC60-1-120C CC60-1-230C

120V, 60", Single lamp fixture, "Power Port" connection 208/230V, 60", Single lamp fixture, "Power Port" connection One junction box and one end cap required per row

CC60-2-120 CC60-2-230 CC60-2-277

120V, 60", 2 lamp fixture, hardwire connection 208/230V, 60", 2 lamp fixture, hardwire connection 277V, 60", 2 lamp fixture, hardwire connection

CC60-2-120C CC60-2-230C

120V, 60", 2 lamp fixture, "Power Port" connection 208/230V, 60", 2 lamp fixture, "Power Port" connection One junction box and one end cap required per row

GCL 60 Lamp for all CC60 Fixtures

Junction box, End Cap and Ballasts

2540 15B Junction box (1 per row) 2540 18 Row end cap (1 per row) CORDKIT 120V 8' power cord kit with strain relief TXG270 TXG275 TXG280

Ballast for 120V Fixtures (except CC60) Ballast for 230/208V fixtures (except CC60) Ballast for 277V fixtures (except CC60)

TXG285 TXG290 TXG295

Ballast for 120V CC60 Fixtures Ballast for 2300V CC60 Fixtures Ballast for 277V CC60 Fixtures

Mounting Rails and Brackets – "A" bracket attachment to Coil Frame 2570-02 "A" bracket hanger with bolts & nuts to attach to mounting rail 2570-01 Aluminum Horizontal Light Rail – 3.04"H x 1.13"D 2570-03 CC fixture Mounting Kit with 2 bolts, 2 nuts, 2 lock washers

Note: Add 3" – 6" to each horizontal fixture rail length for attachment to "A" bracket. Specify cut length dimensions and place order in inches

Vertical and Horizontal Frame Mounting Rack 2570-01 Vertical aluminum extrusion support legs – 3.04"H x 1.13"D 2570-01 Aluminum Horizontal Light Rail – 3.04"H x 1.13"D 2570-03 CC fixture Mounting Kit with 2 bolts, 2 nuts, 2 lock washers

Note: The maximum allowable span between vertical support legs is ten feet (10') Attachment of the horizontal rails to the vertical support legs is by means of field assembly and field supplied parts (drill, tap and join with sheet metal bolts, nuts, lock washers)

Fully Assembled Rack Systems We can provide complete rack systems (including appropriate CC fixtures) to specified dimensions, fully wired and ready for installation. Please contact us for design and pricing

Specify voltage and type of connection – "plug-in" or "hardwire" when ordering.

With questions about CC systems contact American Air & Water at 888-378-4892 or [email protected]

Page 6: Commercial UV Products - American Air & Water, Inc Surface Mounted Fixtures UF Utility Fixtures CE Closed End Reflector Fixtures TB & CM In-Room Fixtures RT Recessed Troffers & DB

AMERICAN AIR & WATER®, INC.

American Air & Water®, Inc. * 12 Gibson Drive * Hilton Head Island, SC 29926 Phone: 843-785-8699 * 888-378-4892 * Fax: 843-785-2064 * www.americanairandwater.com

Prices subject to change without notice. All cancelled orders are subject to a 30% restocking fee. Past due invoices are subject to a 1.5% per month interest fee.

6Sep12

CC INSTALLATION INSTRUCTIONS *

1. The CC UV fixtures should be mounted on suitable support angle or channel and positioned across coil face as shown on the drawing.

a. If support channels are provided by American Air & Water, Inc., fixtures will be pre-assembled and pre-wired to support channels at factory.

b. If others furnish support members, mount utility fixtures to supports as shown on the drawing. 2. Install mounted fixture assemblies into AHU as follows:

a. Position fixture and rail assemblies as shown on the supplied arrangement drawing. b. For American Air & Water, Inc. supplied rails, drill 3/8” diameter holes into AHU wall in the

positions shown on the arrangement drawing. c. Use 5/16” hardware for securing mounting rails to wall.

3. Supply power to each row of fixtures as required - Supply power can be parallel wired through a DPDT safety switch mounted to maintenance access panels for safety reasons. 4. Optional UVC Sensor can be mounted by drilling a 9/16” diameter hole in the duct wall. A connecting cable can be provided in any specified length to run from the sensor(s) to the panel mount monitor. The panel mount monitor can be mounted in existing enclosure or can be provided with an enclosure as an option.

CC Installation Specifications The Coil Clean (CC) systems are designed for HVAC cooling coil disinfection to mount across the face of the coil singularly or in grid patterns to irradiate the entire surface of the coil. Typical installations require (1) CC36-2 fixture per 10 square feet of coil surface, mounted approximately 18” from the coil surface. On existing systems, CC fixtures should be mounted downstream of the cooling coil facing the coil. All CC models are moisture proof, with unique quartz sleeve/lamp combination and moisture proof power connection.

Visualization Drawing Air stream 18" CC Fixtures CC Fixtures Coil - Front View Coil - Side View _____________________ * Complete Installation Instructions and Installation Drawings are provided for each job.

Page 7: Commercial UV Products - American Air & Water, Inc Surface Mounted Fixtures UF Utility Fixtures CE Closed End Reflector Fixtures TB & CM In-Room Fixtures RT Recessed Troffers & DB

AMERICAN AIR & WATER®, INC.

American Air & Water®, Inc. * 12 Gibson Drive * Hilton Head Island, SC 29926 Phone: 843-785-8699 * 888-378-4892 * Fax: 843-785-2064 * www.americanairandwater.com

Prices subject to change without notice. All cancelled orders are subject to a 30% restocking fee. Past due invoices are subject to a 1.5% per month interest fee.

7Sep12

DC - DUCT CLEANERS SPECS

Tested and proven performers, DC consist of High Output ultraviolet lamps, ballast and accessory assembly, providing architects and engineers with a complete unit to meet all requirements. The units are manufactured in different series for commercial and industrial installations. The DC include 2- and 4-lamp, voltage specific systems for 120/277V, 60Hz or 220V, 50Hz. Individually or in combination with like units and/or High Output Coil Clean (CC), they adapt to HVAC systems. The units can be installed during or after construction by cutting a small hole in the duct wall for lamp insertion and fastening the transformer section to the exterior wall surface. The DC mounting surface features an airtight gasket. A simple support bracket is available for large plenum chambers. The High Output DC units play an important part in preventing the spread of indoor airborne infections. Tests reveal that disinfected indoor air can have a microbial count lower than that of outdoor air. DC units have been proven necessary in food plants, pharmaceutical production, hospitals, laboratories and government buildings.

4-lamp DC Model 2-lamp DC Model

DC33-4 DC33-2

All DC models use SBL high output UV lamps with effective life of 17,000 hours.

Applications: DC Series fixtures are used for external installation in medium to large air handling systems in commercial, industrial, health care and institutional buildings. DC45 Series - Large Duct Heavy Commercial, Industrial Installations DC33 Series - Large Duct Commercial, Industrial Installations DC24 Series - Medium Duct Commercial, Light Industrial Installations DC16 Series - Medium Duct Light Commercial Installations DC14 Series – Small/Medium Duct Light Commercial Installations DC Series Fixtures are designed for easy access lamp changes that do not require you to un-mount housing from ducting - simply remove the rear access panel, slide over the lamp retaining clips and remove the lamps. All electronic components are housed outside the ducting, including lamp power connection, which eliminates moisture concerns. Lamps are rated for two-year continuous operational life with approximately 20% drop in UVC output at end of lamp life. Custom-Designed Grid Units can be fabricated to suit any special requirement. Our Engineering Division will be glad to cooperate in their development. We can design and fabricate any unit to your requirements. Unlimited modular combinations are available in semi-custom designs.

Page 8: Commercial UV Products - American Air & Water, Inc Surface Mounted Fixtures UF Utility Fixtures CE Closed End Reflector Fixtures TB & CM In-Room Fixtures RT Recessed Troffers & DB

AMERICAN AIR & WATER®, INC.

American Air & Water®, Inc. * 12 Gibson Drive * Hilton Head Island, SC 29926 Phone: 843-785-8699 * 888-378-4892 * Fax: 843-785-2064 * www.americanairandwater.com

Prices subject to change without notice. All cancelled orders are subject to a 30% restocking fee. Past due invoices are subject to a 1.5% per month interest fee.

8Sep12

DC DUCT CLEANERS PRICES

The High Output high grade stainless steel DC units attach to air ducts. Available in 120/230/277V, 50/60Hz. Specify voltage when ordering. SBL lamps effective for 17,000 hours. Each lamp contains ≤8mg mercury.

DC Model Description UVC Watts UVC Intensity* µW/cm² @1m

Duct Cleaner - 14" insertion DC14-2-120/230/277 Two high output lamps 17 198 DC14-4-120/230/277 Four high output lamps 34 396 SBL410 14" high output replacement lamp 8.5 99 Duct Cleaner - 16" insertion DC16-2-120/230/277 Two high output lamps 20 234 DC16-4-120/230/277 Four high output lamps 40 468 SBL430 16" high output replacement lamp 10 117

Duct Cleaner - 24" insertion DC24-2-120/230/277 Two high output lamps 32.4 378 DC24-4-120/230/277 Four high output lamps 64.8 756 SBL415 24" high output replacement lamp 16.2 189

Duct Cleaner - 33" insertion DC33-2-120/230/277 Two high output lamps 50 544 DC33-4-120/230/277 Four high output lamps 100 1,088 SBL420 33" high output replacement lamp 25 272

Duct Cleaner - 45" insertion DC45-2-120/230/277 Two high output lamps 72.2 760 DC45-4-120/230/277 Four high output lamps 144.4 1,520 SBL445 45" high output replacement lamp 36.1 380 Optional Lamp Indicators and Replacement Ballasts

EL/HV or EL/HV 220 Tube Guard lamp indicator, electrically operating per ballast 120 or 220V

TXG270 120V Ballast for 2 SBL405,430,415 or 1 SBL420,445 lamps TXG275 230V Ballast for 2 SBL405,430,415 or 1 SBL420,445 lamps TXG280 277V Ballast for 2 SBL405,430,415 or 1 SBL420,445 lamps * Specified UV intensity measured at 45° F at 400FPM air flow. Warranty: Two-year (17,000 hours) guarantee on lamps with only 20% decrease in output over the two year period Five-year, non-prorated warranty on the ballast and stainless steel chassis Sizing: For calculating the number and size of DC fixtures needed for an installation please use Duct-Calculator Excel calculator located on-line at: http://www.americanairandwater.com/hvac/DC-sizing.htm. You can also request the Excel calculator or technical support at 888-378-4892 or [email protected]

Page 9: Commercial UV Products - American Air & Water, Inc Surface Mounted Fixtures UF Utility Fixtures CE Closed End Reflector Fixtures TB & CM In-Room Fixtures RT Recessed Troffers & DB

AMERICAN AIR & WATER®, INC.

American Air & Water®, Inc. * 12 Gibson Drive * Hilton Head Island, SC 29926 Phone: 843-785-8699 * 888-378-4892 * Fax: 843-785-2064 * www.americanairandwater.com

Prices subject to change without notice. All cancelled orders are subject to a 30% restocking fee. Past due invoices are subject to a 1.5% per month interest fee.

9Sep12

NC (NEMA 4X) UV SYSTEMS The NC (NEMA 4X) high output germicidal UV Systems are mounted externally with only the lamp(s) inserted in the air handler or duct to disinfect the airstream. The NS systems include weather-resistant NEMA 4X housing that makes them ideal for outdoor HVAC units. Applications NC (NEMA 4X) fixtures are installed on the exterior of rooftop A/C units or ductwork and enable easy access to difficult to reach outdoor locations. They are available in one-lamp and two-lamp configurations and can be installed vertically or horizontally. Only the lamp(s) and input power wiring penetrate the HVAC unit, while ballast and lamp harness remain external (housed inside the NEMA 4X enclosure). NC (NEMA 4X) Fixtures utilize high-output “green” lamps (≤ 8 mg of mercury; 2-year guarantee) with five-year ballasts (non-prorated 5-year warranty) into a convenient kit that delivers the best and longest-lasting UVC performance available. Independent tests show that the NC fixtures deliver greater output than any other ultraviolet devices under HVAC operating conditions (45° F at 400 fpm air velocity), and the increased output of our lamps provide the most reliable germicidal performance and longest service life. NC (NEMA 4X) systems utilize high-output, (800mA), T5 diameter lamps, constructed of hard glass tubing for superior UV transmittance. They come in lengths of 14, 16, 24, 33 and 45 inches to meet different size requirements. The lamps produce no ozone and retain, at a minimum, 80% of their initial output after 2 years (17,000 hours). The NC fixtures are available with four voltage options (115/208/230/277 VAC, 50/60 Hz, single phase). Benefits:

Improves Indoor Air Quality (IAQ) by reducing bacteria, viruses and mold that either grow or pass

through the packaged equipment. Reduces the risk of cold, flu, allergies and other illnesses associated with room unit HVAC systems

High-output, “green” lamps contain ≤ 8 mg of mercury Two–year (17,000 hours) guarantee on lamps with only 20% decrease in output over the two years Five-year non-prorated warranty on the ballast Reduces HVAC energy costs by restoring heat transfer and net cooling capacity Continuously cleans coils and drain pans, eliminating costly cleaning programs and the use of harmful

chemicals and disinfectants Produces no ozone or other secondary contaminants Quick and easy snap-in installation

SPECIFICATIONS: The NC Systems lamp and power supply are factory assembled and tested in the USA prior to shipment. Each assembly shall consist of NEMA 4X housing, electronic ballast(s), lamp(s) and wiring harness. FIXTURE: Housing shall be powder coated aluminum to withstand the elements and HVAC environments, and shall meet NEMA 4X requirements. Housing shall be equipped with a bottom electrical opening to facilitate wiring fixture to the HVAC unit’s power. It shall incorporate all components into one integral assembly that maximizes integrity and serviceability. It shall be designed for mounting from outside the airstream with only

NC (NEMA 4X) Fixtures For Outdoor Installation

Page 10: Commercial UV Products - American Air & Water, Inc Surface Mounted Fixtures UF Utility Fixtures CE Closed End Reflector Fixtures TB & CM In-Room Fixtures RT Recessed Troffers & DB

AMERICAN AIR & WATER®, INC.

American Air & Water®, Inc. * 12 Gibson Drive * Hilton Head Island, SC 29926 Phone: 843-785-8699 * 888-378-4892 * Fax: 843-785-2064 * www.americanairandwater.com

Prices subject to change without notice. All cancelled orders are subject to a 30% restocking fee. Past due invoices are subject to a 1.5% per month interest fee.

10Sep12

the lamp(s) in the conditioned air. The lamp mounting shall allow for quick and easy removal during lamp replacement. BALLAST: The solid-state ballast (furnished with this kit) is a Class P rapid start with a power factor minimum of .95. It is available as a 120, 208, 230 or 277 VAC 50/60 Hz, single phase, and is designed to maximize photon production in air temperatures of 35-170° F. Minimum ballast start temperature is – 20 degrees F. Ballasts have a RFI - EMI rating as defined by FCC part 18A for industrial/commercial applications in regards to suppression. Ballast is UL listed for use in HVAC applications. LAMPS: NC (NEMA 4X) systems utilize high-output (800mA), T5 diameter lamps, constructed of hard glass tubing for superior UV transmittance. Lamps are “green” containing ≤ 8mg of mercury and they produce no ozone. Lamps shall retain, at a minimum, 80% of initial output after 2 years (17,000 hours) of use. Electrodes are designed to maximize plasma convection and stability for superior lamp performance and life. Lamps are rated to produce 11.7 µW/cm² per linear inch of lamp arc length at a distance of 1 meter in a 45° F and 400 fpm airstream. INDEPENDENT TESTING: Units are tested by an independent test laboratory in accordance with the general provisions of IES Lighting Handbook, 1981 Applications Volume, and provide output per inch of glass of not less than 11.7 µW/cm² at 1 meter in a 400 fpm airstream of 45° F.

Single Lamp NC Systems - Ordering Specifications

1-lamp Models

Insertion Depth Lamp Voltage Quantity

/box Weight

NC14-1-120 14” SBL410 120 6 71

NC14-1-230 14” SBL410 208/230 6 71

NC14-1-277 14” SBL410 277 6 71

NC16-1-120 16” SBL430 120 6 74

NC16-1-230 16” SBL430 208/230 6 74

NC16-1-277 16” SBL430 277 6 74

NC24-1-120 24” SBL415 120 6 77

NC24-1-230 24” SBL415 208/230 6 77

NC24-1-277 24” SBL415 277 6 77

NC33-1-120 33” SBL420 120 6 80

NC33-1-230 33” SBL420 208/230 6 80

NC33-1-277 33” SBL420 277 6 80

NC45-1-120 45” SBL445 120 6 83

NC45-1-230 45” SBL445 208/230 6 83

NC45-1-277 45” SBL445 277 6 83 2-lamp NC models on next page

Page 11: Commercial UV Products - American Air & Water, Inc Surface Mounted Fixtures UF Utility Fixtures CE Closed End Reflector Fixtures TB & CM In-Room Fixtures RT Recessed Troffers & DB

AMERICAN AIR & WATER®, INC.

American Air & Water®, Inc. * 12 Gibson Drive * Hilton Head Island, SC 29926 Phone: 843-785-8699 * 888-378-4892 * Fax: 843-785-2064 * www.americanairandwater.com

Prices subject to change without notice. All cancelled orders are subject to a 30% restocking fee. Past due invoices are subject to a 1.5% per month interest fee.

11Sep12

Double Lamp NC Systems - Ordering Specifications

2-lamp Models

Insertion Depth

Lamp 2 needed Voltage Quantity

/box Weight

NC14-2-120 14” SBL410 120 6 74

NC14-2-230 14” SBL410 208/230 6 74

NC14-2-277 14” SBL410 277 6 74

NC16-2-120 16” SBL430 120 6 77

NC16-2-230 16” SBL430 208/230 6 77

NC16-2-277 16” SBL430 277 6 77

NC24-2-120 24” SBL415 120 6 80

NC24-2-230 24” SBL415 208/230 6 80

NC24-2-277 24” SBL415 277 6 80

NC33-2-120 33” SBL420 120 6 83

NC33-2-230 33” SBL420 208/230 6 83

NC33-2-277 33” SBL420 277 6 83

NC45-2-120 45” SBL445 120 6 86

NC45-2-230 45” SBL445 208/230 6 86

NC45-2-277 45” SBL445 277 6 86

Replacement Lamps and Ballasts for the NC systems

Model Description Quantity /box Box Weight

SBL410 Lamp for all NC14 Fixtures 16 10

SBL430 Lamp for all NC16 Fixtures 16 10

SBL415 Lamp for all NC24 Fixtures 16 10

SBL420 Lamp for all NC33 Fixtures 16 10

SBL445 Lamp for all NC45 Fixtures 16 10

TXG270 Ballast for all 120V NC Fixtures 1 5

TXG275 Ballast for all 230/208V NC fixtures 1 5

TXG280 Ballast for all 277V NC fixtures 1 5

Page 12: Commercial UV Products - American Air & Water, Inc Surface Mounted Fixtures UF Utility Fixtures CE Closed End Reflector Fixtures TB & CM In-Room Fixtures RT Recessed Troffers & DB

AMERICAN AIR & WATER®, INC.

American Air & Water®, Inc. * 12 Gibson Drive * Hilton Head Island, SC 29926 Phone: 843-785-8699 * 888-378-4892 * Fax: 843-785-2064 * www.americanairandwater.com

Prices subject to change without notice. All cancelled orders are subject to a 30% restocking fee. Past due invoices are subject to a 1.5% per month interest fee.

12Sep12

PEK - PACKAGED EQUIPMENT KIT UV SYSTEMS

PEK High Output UV germicidal fixtures are designed specifically for fan coils, Packaged Terminal Air Conditioners (PTAC), classroom unit ventilators, packaged split systems and other similar room unit systems. The PEK systems use practical and effective UVC technology to overcome the Indoor Air Quality (IAQ) challenge other small in-room packaging equipment hasn’t been able to solve because they’re often equipped with low-efficiency filters that cannot effectively capture infectious contaminants or mold. In addition, because of space and airflow limitation, many of these other units cannot be retrofitted with high-efficiency filtration. Applications PEK fixtures feature lamps that illuminate cooling units with high-output (800mA) UVC energy that eliminates surface contaminants (mold, bacteria and other microbial biofilms) and reduce infectious airborne microbial contaminants, bringing improved IAQ to hotel/motel rooms, dormitories, offices, patient rooms, classrooms and other similar rooms. PEK Fixtures utilize high-output “green” lamps (≤ 8 mg of mercury; 2-year guarantee) with five-year ballasts (non-prorated 5-year warranty) into a convenient kit that delivers the best and longest-lasting UVC performance available. Independent tests show that the PEK fixtures deliver greater output than any other ultraviolet devices under HVAC operating conditions (45° F at 400 fpm air velocity), and the increased output of our lamps provide the most reliable germicidal performance and longest service life. Each PEK system contains one “green” UVC Lamp, one 5-year ballast, and all necessary hardware components to retrofit the room unit with UVC, including wire, holding clips, mounting screws and wire ties - the space-saving, snap-in design fits all major brands. The cell lamps come in lengths of 14, 16, 20, 24, 36, 48 and 60 inches to meet different size requirements. The correct quantity of kits and/or lamp lengths must be selected to irradiate the entire coil. Benefits:

Improves Indoor Air Quality (IAQ) by reducing

bacteria, viruses and mold that either grow or pass through the packaged equipment. Reduces the risk of cold, flu, allergies and other illnesses associated with room unit HVAC systems

High-output, “green” lamps contain ≤ 8 mg of mercury

Two–year (17,000 hours) guarantee on lamps with only 20% decrease in output over the two years

Five-year non-prorated warranty on the ballast Water tight connections for lamp and wiring Reduces HVAC energy costs by restoring heat transfer and net cooling capacity Continuously cleans coils and drain pans, eliminating costly cleaning programs and the use of harmful

chemicals and disinfectants Produces no ozone or other secondary contaminants Quick and easy snap-in installation

Remote High Output lamp with water-tight connection

PEK Fixtures are ideal for use in: Packaged Terminal Air Conditioners

(PTAC)

Classroom Unit Ventilators

Fan Coils

Packaged Split Systems

Applications With Limited Space

GTLK Shatterproof Systems GTLK fixtures feature a shatterproof Fluoro Ethylene Polymer coating on GTL lamps that replaces the outer quartz sleeve used for lamps in the PEK Series.

GTLK fixtures use the same ballasts, and are available in identical lengths and voltages, as PEK fixtures.

Page 13: Commercial UV Products - American Air & Water, Inc Surface Mounted Fixtures UF Utility Fixtures CE Closed End Reflector Fixtures TB & CM In-Room Fixtures RT Recessed Troffers & DB

AMERICAN AIR & WATER®, INC.

American Air & Water®, Inc. * 12 Gibson Drive * Hilton Head Island, SC 29926 Phone: 843-785-8699 * 888-378-4892 * Fax: 843-785-2064 * www.americanairandwater.com

Prices subject to change without notice. All cancelled orders are subject to a 30% restocking fee. Past due invoices are subject to a 1.5% per month interest fee.

13Sep12

SPECIFICATIONS: The PEK series lamp and power supply is factory assembled and tested in the USA prior to shipment. Each kit shall consist of a power supply, lamp cord and high-output lamp. BALLAST: The solid-state ballast (furnished with this kit) is a Class P rapid start with a power factor minimum of .95. It is available as a 120, 208, 230 or 277 VAC 50/60 Hz, single phase, and is designed to maximize photon production in air temperatures of 35-170° F. Minimum ballast start temperature is – 20 degrees F. Ballasts have a RFI - EMI rating as defined by FCC part 18A for industrial/commercial applications in regards to suppression. Ballast is UL listed for use in HVAC applications. LAMPS: PEK series lamps are high-output (800mA), T5 diameter, and constructed from hard glass tubing for superior UV transmittance. Lamps are “green,” containing ≤ 8mg of mercury and they produce no ozone. Lamps shall retain, at a minimum, 80% of initial output after 2 years (17,000 hours) of use. They are sealed for moisture protection with a water-tight connection. Electrodes are designed to maximize plasma convection and stability for superior lamp performance and life. Lamps are rated to produce 11.7 µW/cm² per linear inch of lamp arc length at a distance of one meter in a 45° F and 400 fpm airstream. KIT COMPONENTS: The wire shall be UV-resistant and rated for installation in an HVAC system. The spring mounting clips shall be provided with mounting screws and custom designed to hold the UVC Lamp without damaging the tube during installation or replacement. INDEPENDENT TESTING: Units are tested by an independent test laboratory in accordance with the general provisions of IES Lighting Handbook, 1981 Applications Volume, and provide output per inch of glass of not less than 11.7 µW/cm² at 1 meter in a 400 fpm airstream of 45° F.

Technical Data

Models Lamp Length Lamp Voltage Ballast Dims (in) Amp Draw

PEK-18-120 16” GCL-18 120 1.00 x 1.72 x 8.60 0.25 PEK-18-230 16” GCL-18 208/230 1.00 x 1.72 x 9.60 0.15 PEK-18-277 16” GCL-18 277 1.00 x 1.72 x 9.60 0.10 PEK-24-120 22” GCL-24 120 1.00 x 1.72 x 8.60 0.60 PEK-24-230 22” GCL-24 208/230 1.00 x 1.72 x 9.60 0.35 PEK-24-277 22” GCL-24 277 1.00 x 1.72 x 9.60 0.30 PEK-36-120 34” GCL-36 120 1.00 x 1.72 x 8.60 0.80 PEK-36-230 34” GCL-36 208/230 1.00 x 1.72 x 9.60 0.40 PEK-36-277 34” GCL-36 277 1.00 x 1.72 x 9.60 0.35 PEK-48-120 46” GCL-48 120 1.00 x 1.72 x 8.60 1.15 PEK-48-230 46” GCL-48 208/230 1.00 x 1.72 x 9.60 0.60 PEK-48-277 46” GCL-48 277 1.00 x 1.72 x 9.60 0.50 PEK-60-120 58” GCL-60 120 1.00 x 1.72 x 19.25 1.60 PEK-60-230 58” GCL-60 208/230 1.00 x 1.72 x 19.25 0.80 PEK-60-277 58” GCL-60 277 1.00 x 1.72 x 19.25 0.70

Page 14: Commercial UV Products - American Air & Water, Inc Surface Mounted Fixtures UF Utility Fixtures CE Closed End Reflector Fixtures TB & CM In-Room Fixtures RT Recessed Troffers & DB

AMERICAN AIR & WATER®, INC.

American Air & Water®, Inc. * 12 Gibson Drive * Hilton Head Island, SC 29926 Phone: 843-785-8699 * 888-378-4892 * Fax: 843-785-2064 * www.americanairandwater.com

Prices subject to change without notice. All cancelled orders are subject to a 30% restocking fee. Past due invoices are subject to a 1.5% per month interest fee.

14Sep12

GTLK fixtures feature shatterproof Fluoro Ethylene Polymer coating on GTL lamps that replaces the outer quartz sleeve used for lamps in the PEK Series. GTLK fixtures use the same ballasts, and are available in similar lengths and voltages, as PEK fixtures.

GTLK Technical Specs

Model Description Lamp

AAWGTLKHO/14T/120-277 Packaged Equipment Kit w/14" shatterproof lamp, 120/240/277V 50/60Hz AAWHO/14T

GTLK-18-120 Packaged Equipment Kit w/18" shatterproof lamp, 120V GTL-18 GTLK-18-230 Packaged Equipment Kit w/18" shatterproof lamp, 208/230V GTL-18 GTLK-18-277 Packaged Equipment Kit w/18" shatterproof lamp, 277V GTL-18 GTLK-24-120 Packaged Equipment Kit w/24" shatterproof lamp, 120V GTL-24 GTLK-24-230 Packaged Equipment Kit w/24" shatterproof lamp, 208/230V GTL-24 GTLK-24-277 Packaged Equipment Kit w/24" shatterproof lamp, 277V GTL-24 GTLK-36-120 Packaged Equipment Kit w/36" shatterproof lamp, 120V GTL-36 GTLK-36-230 Packaged Equipment Kit w/36" shatterproof lamp, 208/230V GTL-36 GTLK-36-277 Packaged Equipment Kit w/36" shatterproof lamp, 277V GTL-36 GTLK-48-120 Packaged Equipment Kit w/48" shatterproof lamp, 120V GTL-48 GTLK-48-230 Packaged Equipment Kit w/48" shatterproof lamp, 208/230V GTL-48 GTLK-48-277 Packaged Equipment Kit w/48" shatterproof lamp, 277V GTL-48 GTLK-60-120 Packaged Equipment Kit w/60" shatterproof lamp, 120V GTL-60 GTLK-60-230 Packaged Equipment Kit w/60" shatterproof lamp, 208/230V GTL-60 GTLK-60-277 Packaged Equipment Kit w/60" shatterproof lamp, 277V GTL-60

Replacement Lamps & Ballasts for the GTLK systems

Model Description AAWHO/14T 14" shatterproof lamp

GTL-18 18" shatterproof lamp

GTL-24 24" shatterproof lamp

GTL-36 36" shatterproof lamp

GTL-48 48" shatterproof lamp

GTL-60 60" shatterproof lamp, 208/230V

TXG270 Ballast for 120V Fixtures (except PEK�60)

TXG275 Ballast for 230/208V fixtures (except PEK-60)

TXG280 Ballast for 277V fixtures (except PEK-60)

TXG285 Ballast for 120V PEK-60 Fixtures

TXG290 Ballast for 230V PEK-60 Fixtures

TXG295 Ballast for 277V PEK-60 Fixtures

Remote High Output lamp with moisture resistant connection

Page 15: Commercial UV Products - American Air & Water, Inc Surface Mounted Fixtures UF Utility Fixtures CE Closed End Reflector Fixtures TB & CM In-Room Fixtures RT Recessed Troffers & DB

AMERICAN AIR & WATER®, INC.

American Air & Water®, Inc. * 12 Gibson Drive * Hilton Head Island, SC 29926 Phone: 843-785-8699 * 888-378-4892 * Fax: 843-785-2064 * www.americanairandwater.com

Prices subject to change without notice. All cancelled orders are subject to a 30% restocking fee. Past due invoices are subject to a 1.5% per month interest fee.

15Sep12

SM SURFACE MOUNTED FIXTURES SPECS The dust-free design of the SM fixtures ensures a lifetime of dependability and contemporary appearance. The SM fixtures utilize specular aluminum reflectors for maximum UV efficiency. SM fixtures are available in one or two lamp models in various lengths.

Optional aluminum guardrails protect the UV lamp from breakage in congested areas. The guardrail fixtures have an overall height of 4⅝" and same length and width. The lamps may be replaced without disassembly of guardrail. The guardrails also could be made of stainless steel. The SM Fixtures are designed for hospitals, laboratories and clean room applications. Regular cleaning and relamping is required for maximum germicidal effectiveness. Technical Data Single lamp Models Lamp # UV Watts Mounting

Template Dimensions

Length x Width x Height Lamp Life

SM-30-C GML010 8.3 3 37” x 5⅜ x 4⅛ 10,000 hours SM-20-C GML025 5.5 2 27” x 5⅜ x 4⅛ 10,000 hours SM-10-C GML020 2.8 1 18⅛” x 5⅜ x 4⅛ 10,000 hours SM-36 * GML005 13.8 3 37” x 5⅜ x 4⅛ 10,000 hours SM-10-SL GML060 5.3 1 18⅛” x 5⅜ x 4⅛ 10,000 hours SM-30-H GML220 8.3 3 37” x 5⅜ x 4⅛ 10,000 hours SM-25-H GML215 5.0 1 18⅛” x 5⅜ x 4⅛ 10,000 hours SM-15-H GML210 3.6 1 18⅛” x 5⅜ x 4⅛ 10,000 hours Double lamp Models Lamp # UV Watts Mounting

Template Dimensions

Length x Width x Height Lamp Life

SM-30-2C GML010 (2) 16 3 37” x 5⅜ x 4⅛ 10,000 hours SM-20-2C GML025 (2) 11 2 27” x 5⅜ x 4⅛ 10,000 hours SM-10-2C GML020 (2) 5.6 1 18⅛” x 5⅜ x 4⅛ 10,000 hours SM-36-2 * GML005 (2) 27.6 3 37” x 5⅜ x 4⅛ 10,000 hours SM-30-2H GML220 (2) 16.6 3 37” x 5⅜ x 4⅛ 10,000 hours SM-25-2H GML215 (2) 10 1 18⅛” x 5⅜ x 4⅛ 10,000 hours SM-15-2H GML210 (2) 7.2 1 18⅛” x 5⅜ x 4⅛ 10,000 hours * SM-36 and SM-36-2 have electronic ballast which can automatically handle 110/220/277V / 50/60Hz. For all other models, please specify required voltage. All ballasts are UL Listed.

Mounting Template 1 Mounting Template 2 Mounting Template 3 A 4 1/4" B 7" 5 9/16"

A 4 1/4" B 11.5" 10"

A 4 1/4" B 16.5" 15"

A – 1/4" Mounting Holes B – 7/8" Knock-outs for box mounting

C A U T I O N MALE ENDS OF LAMP HOLDER RECEPTACLE ARE SPRING LOADED.

IF ALLOWED TO SNAP BACK THEY MIGHT CRACK.

Page 16: Commercial UV Products - American Air & Water, Inc Surface Mounted Fixtures UF Utility Fixtures CE Closed End Reflector Fixtures TB & CM In-Room Fixtures RT Recessed Troffers & DB

AMERICAN AIR & WATER®, INC.

American Air & Water®, Inc. * 12 Gibson Drive * Hilton Head Island, SC 29926 Phone: 843-785-8699 * 888-378-4892 * Fax: 843-785-2064 * www.americanairandwater.com

Prices subject to change without notice. All cancelled orders are subject to a 30% restocking fee. Past due invoices are subject to a 1.5% per month interest fee.

16Sep12

SM SURFACE MOUNTED FIXTURES PRICES

Surface-mount fixtures with dust free design feature stainless steel construction and specular aluminum reflector cover with or without guardrails to deliver 254nm germicidal ultraviolet radiation for various applications.

Length Model Description Deluxe surface mount fixture (37" L x 5-5/8" W x 4-1/8" D) SM-30-C Single cold cathode (GML010) lamp SM-30-2C Double cold cathode (GML010) lamps SM-36 Single slimline (GML005) lamp SM-36-200 One slimline (GML005), 200 MA - OR35 LS light shield SM-36-2 Double slimline (GML005) lamps SM-30-H Single hot cathode (GML220) lamp SM-30-2H Double hot cathode (GML220) lamps

Deluxe surface mount fixture with Guard Rails (37" L x 5-5/8" W x 4-5/8" D) SM-30-CGR Single cold cathode (GML010) lamp SM-30-2CGR Double cold cathode (GML010) lamps SM-36GR Single slimline (GML005) lamp

37"

SM-36-2GR Double slimline (GML005) lamps Deluxe surface mount fixture (27" L x 5-5/8" W x 4-1/8" D)

SM-20-C Single cold cathode (GML025) lamp SM-20-2C Double cold cathode (GML025) lamps

Deluxe surface mount fixture with Guard Rails (27" L x 5-5/8" W x 4-5/8" D) SM-20-CGR Single cold cathode (GML025) lamp

27"

SM-20-2CGR Double cold cathode (GML025) lamps Deluxe surface mount fixture (18-1/8" L x 5-5/8" W x 4-1/8" D)

SM-10-C Single cold cathode (GML020) lamp SM-10-2C Double cold cathode (GML020) lamps SM-10-SL Single slimline (GML060) lamp SM-10-2SL Double slimline (GML060) lamps SM-25-H Single hot cathode (GM215) lamp SM-25-2H Double hot cathode (GML215) lamps SM-15-H Single hot cathode (GM210) lamp SM-15-2H Double hot cathode (GML210) lamps

Deluxe surface mount fixture with Guard Rails (18-1/8" L x 5-5/8" W x 4-5/8" D) SM-10-CGR Single cold cathode (GML020) lamp SM-10-2CGR Double cold cathode (GML020) lamps SM-10-SLGR Single slimline (GML060) lamp

18"

SM-10-2SLGR Double slimline (GML060) lamps Warning: Care should be taken to ensure that personnel are not exposed to direct or reflected UV light. Suitable eye and skin protection should be employed when lamp is in operation. Before cleaning or relamping, always turn the power OFF.

Page 17: Commercial UV Products - American Air & Water, Inc Surface Mounted Fixtures UF Utility Fixtures CE Closed End Reflector Fixtures TB & CM In-Room Fixtures RT Recessed Troffers & DB

AMERICAN AIR & WATER®, INC.

American Air & Water®, Inc. * 12 Gibson Drive * Hilton Head Island, SC 29926 Phone: 843-785-8699 * 888-378-4892 * Fax: 843-785-2064 * www.americanairandwater.com

Prices subject to change without notice. All cancelled orders are subject to a 30% restocking fee. Past due invoices are subject to a 1.5% per month interest fee.

17Sep12

SM INSTALLATION INSTRUCTIONS

Fixture Ceiling Heights

7 feet 8 feet 9 feet 10 feet Single Lamp Square feet of floor area per fixture

SM-30-C 46 30 25 20 SM-20-C 31 20 17 14 SM-10-C 17 11 8 7 SM-36 75 49 42 33 SM-10-SL 34 22 18 15 SM-30-H 53 35 29 24 SM-25-H 34 22 18 15 SM-15-H 24 16 13 11

Double Lamp Square feet of floor area per fixture SM-30-2C 69 45 38 31 SM-20-2C 46 30 25 20 SM-10-2C 25 17 14 12 SM-36-2 112 74 62 50 SM-30-2H 79 52 44 35 SM-25-2H 51 34 29 23 SM-15-2H 36 24 20 16 If ceiling is over 10 feet, fixtures should be suspended from ceiling to 10 feet level above the floor.

Example: Inactivation of Aspergillus Niger (Black Mold Spores) requires 330,000 microwatts per square centimeter. In a typical 15’ x 10’ room with 7’ ceiling, two (2) SM-36 fixtures would require 3 hours irradiation time to inactivate all black mold spores at floor level. Calculation: Microwatts/sec. 253.7nm GML005 (420MA) @ 1 meter = 120 x 80” factor: .256 = 30.72 x 60 seconds = 1,843.2 x 60 minutes = 110,592. x 3 hours = 331,776. With 4 fixtures - 150 minutes With 6 fixtures - 100 minutes With 8 fixtures - 80 minutes Higher ceilings require the following multiplier to number of fixtures:

8 feet - x 1.5 9 feet - x 2.0 10 feet - x 3.0

Page 18: Commercial UV Products - American Air & Water, Inc Surface Mounted Fixtures UF Utility Fixtures CE Closed End Reflector Fixtures TB & CM In-Room Fixtures RT Recessed Troffers & DB

AMERICAN AIR & WATER®, INC.

American Air & Water®, Inc. * 12 Gibson Drive * Hilton Head Island, SC 29926 Phone: 843-785-8699 * 888-378-4892 * Fax: 843-785-2064 * www.americanairandwater.com

Prices subject to change without notice. All cancelled orders are subject to a 30% restocking fee. Past due invoices are subject to a 1.5% per month interest fee.

18Sep12

UF UTILITY FIXTURES PRICES

Utility fixturess are available with flat, A-shaped or half-round reflectors for general-purpose air and surface sterilization. Various sizes and configurations are available for all applications.

Length Part # Description Price Each

Utility industrial strip fixture (37" L x 3-1/8" W x 3-7/8" D) UF-30-C Single cold cathode (GML010) lamp UF-30-2C Double cold cathode (GML010) lamps UF-36 Single slimline (GML005) lamp UF-36-2 Double slimline (GML005) lamps UF-30-H Single hot cathode (GML220) lamp

Utility fixture with A-shaped reflector (37" L x 9" W x 5" D) UFA-30-C Single cold cathode (GML010) lamp UFA-30-2C Double cold cathode (GML010) lamps UFA-36 Single slimline (GML005) lamp UFA-36-2 Double slimline (GML005) lamps UFA-30-H Single hot cathode (GML220) lamp

Utility fixture with half-round reflector (37" L x 3-1/8" W x 5-3/8" D) UFR-30-C Single cold cathode (GML010) lamp UFR-30-2C Double cold cathode (GML010) lamps UFR-36 Single slimline (GML005) lamp UFR-36-2 Double slimline (GML005) lamps UFR-30-H Single hot cathode (GML220) lamp

Utility fixture with guard rails (37" L x 3-3/4" W x 4-1/2" D) GR-30-C Single cold cathode (GML010) lamp GR-30-2C Double cold cathode (GML010) lamps GR-36 Single slimline (GML005) lamp

37"

GR-36-2 Double slimline (GML005) lamps Utility industrial strip fixture (27" L x 3-1/8" W x 3-7/8" D)

UF-20-C Single cold cathode (GML025) lamp UF-20-2C Double cold cathode (GML025) lamps

Utility fixture with A-shaped reflector (27" L x 9" W x 5" D) UFA-20-C Single cold cathode (GML025) lamp UFA-20-2C Double cold cathode (GML025) lamps

Utility fixture with half-round reflector (27" L x 3-1/8" W x 5-3/8" D) UFR-20-C Single cold cathode (GML025) lamp UFR-20-2C Double cold cathode (GML025) lamps

Utility fixture with guard rails (27" L x 3-3/4" W x 4-1/2" D) GR-20-C Single cold cathode (GML025) lamp

27"

GR-20-2C Double cold cathode (GML025) lamps Utility industrial strip fixture (19" L x 3-1/8" W x 3-7/8" D) continued

UF-25H Single hot cathode (GML215) lamp 19" UF-15-H Single hot cathode (GML210) lamps

Page 19: Commercial UV Products - American Air & Water, Inc Surface Mounted Fixtures UF Utility Fixtures CE Closed End Reflector Fixtures TB & CM In-Room Fixtures RT Recessed Troffers & DB

AMERICAN AIR & WATER®, INC.

American Air & Water®, Inc. * 12 Gibson Drive * Hilton Head Island, SC 29926 Phone: 843-785-8699 * 888-378-4892 * Fax: 843-785-2064 * www.americanairandwater.com

Prices subject to change without notice. All cancelled orders are subject to a 30% restocking fee. Past due invoices are subject to a 1.5% per month interest fee.

19Sep12

Utility fixture with A-shaped reflector (19" L x 9" W x 5" D)

UFA-25H Single hot cathode (GML215) lamp UFA-15H Single hot cathode (GML210) lamps

Utility fixture with half-round reflector (19" L x 3-1/8" W x 5-3/8" D) UFR-25H Single hot cathode (GML215) lamp

UFR-15H Single hot cathode (GML210) lamps Utility industrial strip fixture (17" L x 3-1/8" W x 3-7/8" D)

UF-10-SL 17 x 3⅛ x 3⅞ n/a UHA-10-SL 17 x 9 x 5 "A" reflector UFR-10-SL 17 x 3⅛ x 5⅜ half-round reflector UF-10-C Single cold cathode (GML020) lamp UF-10-2C Double cold cathode (GML020) lamps

Utility fixture with A-shaped reflector (17" L x 9" W x 5" D) UFA-10-C Single cold cathode (GML020) lamp UFA-10-2C Double cold cathode (GML020) lamps

Utility fixture with half-round reflector (17" L x 3-1/8" W x 5-3/8" D) UFR-10-C Single cold cathode (GML020) lamp UFR-10-2C Double cold cathode (GML020) lamps

Utility fixture with guard rails (17" L x 3-3/4" W x 4-1/2" D) GR-10-C Single cold cathode (GML020) lamp

17"

GR-10-2C Double cold cathode (GML020) lamps Utility industrial strip fixture (14-7/8" L x 2" W x 2" D)

UF-12-BP Single slimline (GML125) lamp Utility fixture with A-shaped reflector (14-1/2" L x 2" W x 2" D)

UFA-12-BP Single slimline (GML125) lamp Utility fixture with half-round reflector (14-7/8" L x 28" W x 2" D)

15"

UFR-12-BP Single slimline (GML125) lamp Utility industrial strip fixture (12-1/2" L x 2" W x 2" D)

UF-8-H Single hot cathode (GML105) lamp Utility fixture with A-shaped reflector (12-1/2" L x 3" W x 3" D)

UFA-8-H Single hot cathode (GML105) lamp Utility fixture with half-round reflector (12-1/2" L x 2" W x 2" D)

12"

UFR-8-H Single hot cathode (GML105) lamp Utility industrial strip fixture (9-1/4" L x 2" W x 2" D)

UF-6-H Single hot cathode (GML195) lamp Utility fixture with A-shaped reflector (9-1/4" L x 3" W x 3" D)

UFA-6-H Single hot cathode (GML195) lamp Utility fixture with half-round reflector (9-1/4" L x 2" W x 2" D)

9"

UFR-6-H Single hot cathode (GML195) lamp Utility industrial strip fixture (6-1/4" L x 2" W x 2" D)

UF-4-H Single hot cathode (GML180) lamp Utility fixture with A-shaped reflector (6-1/4" L x 3" W x 3" D)

UFA-4-H Single hot cathode (GML180) lamp Utility fixture with half-round reflector (6-1/4" L x 2" W x 2" D)

6"

UFR-4-H Single hot cathode (GML180) lamp

Page 20: Commercial UV Products - American Air & Water, Inc Surface Mounted Fixtures UF Utility Fixtures CE Closed End Reflector Fixtures TB & CM In-Room Fixtures RT Recessed Troffers & DB

AMERICAN AIR & WATER®, INC.

American Air & Water®, Inc. * 12 Gibson Drive * Hilton Head Island, SC 29926 Phone: 843-785-8699 * 888-378-4892 * Fax: 843-785-2064 * www.americanairandwater.com

Prices subject to change without notice. All cancelled orders are subject to a 30% restocking fee. Past due invoices are subject to a 1.5% per month interest fee.

20Sep12

CE CLOSED END REFLECTOR FIXTURES SPECS

In ten models with lamp configurations of one to four, these fixtures direct and confine the ultraviolet rays to specific areas. They are designed for use over conveyor lines, laboratory benches or with adjustable legs for product sterilization. Lamp lengths of 4, 6, 8, 12, 18 & 36 inches are available with germicidal and/or blacklight ultraviolet. Technical Data

1 Lamp Models Lamp # UV Output Length Lamp Life

CE-30-C GML010 8.3 W 37” 10,000 hours CE-20-C GML025 5.5 W 27” 10,000 hours CE-10-C GML020 2.8 W 18⅛” 10,000 hours CE-36 GML005 13.8 W 37” 10,000 hours

CE-10-SL GML060 5.3 W 18⅛” 10,000 hours CE-30-H GML220 8.3 W 37” 10,000 hours CE-25-H GML215 5.0 W 18⅛” 10,000 hours CE-15-H GML210 3.6 W 18⅛” 10,000 hours

Note: For the 2, 3 and 4 lamp models the UV output increases by the number of UV lamps used.

CE-M MINIATURE CLOSED END REFLECTOR FIXTURES Miniature Closed-End reflector fixtures are designed for blacklight and germicidal applications. Blacklight and blacklight blue lamps are interchangeable with germicidal lamps which allow the CE-4-H, CE-6-H and CE-8-H to be utilized for ultraviolet inspection and detection applications. Miniature Closed-end reflector fixtures are completely assembled with a cast aluminum handle, power cord and on/off switch. 120V/60Hz electrical operation is standard. Lamp lengths of 4, 6, 8 & 12 inches are available with germicidal and/or blacklight ultraviolet in 1- and 2-lamp models. 1 Lamp Models Lamp # UV Watts Length

CE-12-H GML125 6.0 12” CE-8-H GML205 1.5 12” CE-6-H GML195 1.0 9” CE-4-H GML180 0.5 6” 2 Lamp Models Lamp # UV Watts Length

CE-12-H GML125 (2) 12.0 12” CE-8-2H GML205 (2) 3.0 12” CE-6-2H GML195 (2) 2.0 9” Warning: Care should be taken to ensure that personnel are not exposed to direct or reflected UV light. Suitable eye and skin protection should be employed when light is in operation. Before cleaning or relamping, always turn the power OFF.

Page 21: Commercial UV Products - American Air & Water, Inc Surface Mounted Fixtures UF Utility Fixtures CE Closed End Reflector Fixtures TB & CM In-Room Fixtures RT Recessed Troffers & DB

AMERICAN AIR & WATER®, INC.

American Air & Water®, Inc. * 12 Gibson Drive * Hilton Head Island, SC 29926 Phone: 843-785-8699 * 888-378-4892 * Fax: 843-785-2064 * www.americanairandwater.com

Prices subject to change without notice. All cancelled orders are subject to a 30% restocking fee. Past due invoices are subject to a 1.5% per month interest fee.

21Sep12

CE CLOSED END FIXTURES PRICES

CE reflector fixtures are designed to direct and confine the UV rays to a specific area. CE units are available with 1, 2, 3 or 4 germicidal (254nm) and/or blacklight (365nm) UV lamps for various applications. Length Model Description

Closed end reflector fixture (37" L x 7¼" W x 7½" D) CE-30-C One cold cathode (GML010) lamp CE-30-2C Two cold cathode (GML010) lamps CE-30-3C Three cold cathode (GML010) lamps CE-30-4C Four cold cathode (GML010) lamps CE-36 One slimline (GML005) lamp CE-36-2 Two slimline (GML005) lamps CE-36-3 Three slimline (GML005) lamps CE-36-4 Four slimline (GML005) lamps CE-30-H One hot cathode (GML220) lamp CE-30-2H Two hot cathode (GML220) lamps CE-30-3H Three hot cathode (GML220) lamps CE-30-4H Four hot cathode (GML220) lamps CE-30-BL One black light (BLL065) lamp no filter/white CE-30-2BL Two black light (BLL065) lamps no filter/white CE-30-3BL Three black light (BLL065) lamps no filter/white CE-30-4BL Four black light (BLL065) lamps no filter/white CE-30-BLB One black light blue (BLL070) lamp filter/blue CE-30-2BLB Two black light blue (BLL070) lamps filter/blue CE-30-3BLB Three black light blue (BLL070) lamps filter/blue

37"

CE-30-4BLB Four black light blue (BLL070) lamps filter/blue Closed end reflector fixture (27" L x 7-1/4" W x 7-1/2" D) CE-20-C One cold cathode (GML025) lamps CE-20-2C Two cold cathode (GML025) lamps CE-20-3C Three cold cathode (GML025) lamps

27"

CE-20-4C Four cold cathode (GML025) lamps Closed end reflector fixture (18" L x 7-1/4" W x 7-1/2" D) CE-10-C One cold cathode (GML020) lamp CE-10-2C Two cold cathode (GML020) lamps CE-10-3C Three cold cathode (GML020) lamps CE-10-SL One slimline (GML060) lamp CE-10-2SL Two slimline (GML060) lamps CE-10-4SL Four slimline (GML060) lamps CE-25-H One hot cathode (GML215) lamp CE-25-2H Two hot cathode (GML215) lamps CE-25-3H Three hot cathode (GML215) lamps

18"

CE-25-4H Four hot cathode (GML215) lamps

Page 22: Commercial UV Products - American Air & Water, Inc Surface Mounted Fixtures UF Utility Fixtures CE Closed End Reflector Fixtures TB & CM In-Room Fixtures RT Recessed Troffers & DB

AMERICAN AIR & WATER®, INC.

American Air & Water®, Inc. * 12 Gibson Drive * Hilton Head Island, SC 29926 Phone: 843-785-8699 * 888-378-4892 * Fax: 843-785-2064 * www.americanairandwater.com

Prices subject to change without notice. All cancelled orders are subject to a 30% restocking fee. Past due invoices are subject to a 1.5% per month interest fee.

22Sep12

Length Model Description

Closed end reflector fixture (18" L x 7-1/4" W x 7-1/2" D) continued CE-15-H One hot cathode (GM210) lamp CE-15-2H Two hot cathode (GML210) lamps CE-15-3H Three hot cathode (GM210) lamps CE-15-4H Four hot cathode (GML210) lamps CE-15-BL One black light (BLL040) lamp no filter/white CE-15-2BL Two black light (BLL040) lamps no filter/white CE-15-3BL Three black light (BLL040) lamps no filter/white CE-15-4BL Four black light (BLL040) lamps no filter/white CE-15-BLB One black light blue (BLL045) lamp filter/blue CE-15-2BLB Two black light blue (BLL045) lamps filter/blue CE-15-3BLB Three black light blue (BLL045 lamp filter/blue

18"

CE-15-4BLB Four black light blue (BLL045) lamp filter/blue Closed end reflector fixture (12" L x 3-1/2" W x 4" D) handle, power cord, & switch CE-12-H One hot cathode (GML125) lamp CE-12-2H Two hot cathode (GML125) lamps CE-8-H One hot cathode (GML205) lamp CE-8-2H Two hot cathode (GML205) lamps CE-8-BL One black light (BLL030) lamp no filter/white CE-8-2BL Two black light (BLL030) lamps no filter/white CE-8-BLB One black light blue (BLL035) lamp filter/blue

12"

CE-8-2BLB Two black light blue (BLL035) lamps filter/bllue Closed end reflector fixture (9" L x 3-1/2" W x 4" D) handle, power cord & switch CE-6-H One hot cathode (GML195) lamp CE-6-2H Two hot cathode (GML195) lamps CE-6-BL One black light (BLL020) lamp no filter/white CE-6-2BL Two black light (BLL020) lamps no filter/white CE-6-BLB One black light blue (BLL025) lamp filter/blue

9"

CE-6-2BLB Two black light blue (BLL025) lamps filter/blue Closed end reflector fixture (6" L x 3-1/2" W x 4" D) handle, power cord & switch CE-4-H One hot cathode (GML180) lamp CE-4-BL One black light (BLL010) lamp no filter/white

6"

CE-4-BLB One black light blue (BLL015) lamps filter/blue Double Vision, portable battery operated black light BLL090 Handheld, battery operated unit with one black light (BLL015) lamp filter/blue BLL091 AC adapter for BLL090

Accessories - use with 18" - 37" CE fixtures for free standing adjustable position

AL Adjustable (10"-39") tripod leg stand for CE fixtures

Page 23: Commercial UV Products - American Air & Water, Inc Surface Mounted Fixtures UF Utility Fixtures CE Closed End Reflector Fixtures TB & CM In-Room Fixtures RT Recessed Troffers & DB

AMERICAN AIR & WATER®, INC.

American Air & Water®, Inc. * 12 Gibson Drive * Hilton Head Island, SC 29926 Phone: 843-785-8699 * 888-378-4892 * Fax: 843-785-2064 * www.americanairandwater.com

Prices subject to change without notice. All cancelled orders are subject to a 30% restocking fee. Past due invoices are subject to a 1.5% per month interest fee.

23Sep12

TB, RAM & CM ULTRAVIOLET FIXTURES

The TB in-room fixtures control tuberculosis, as well as other airborne pathogens and mold.

Models TB-W are designed to be wall-mounted to reduce upper air contamination. TB-W fixtures feature adjustable louvers to allow unlimited direction of the ultraviolet rays while protecting personnel and providing maximum germicidal irradiation. The units are constructed of high grade stainless steel with an alzak aluminum reflector. They mount 7 feet above the floor and use SBL lamps. Re-

lamping requires only disconnecting the power and lowering the hinged front louver. TB-W fixtures are shipped assembled and include a grounded power cord, pull-chain switch, ultraviolet lamp and louver. Model RAM36-2 is a totally enclosed air-movement UV system. This fixture comes complete with filters, fans and 2 ultraviolet lamps. It is designed for rooms where congestion or ceiling height prohibits the use of wall-mounted indirect fixtures. Constructed of high grade stainless steel, each fixture produces four or more air changes per hour in rooms up to 200 square feet.

Technical Data Model TB-12-W TB-24-W TB-36-W RAM36-2 Lamp # SBL060 SBL325 SBL005 SBL420 Lamp Life 12,000 hours 12,000 hours 12,000 hours 17,000 hours Lamp Intensity 50 µW/cm² 100 µW/cm² 175 µW/cm² 120 µW/cm² Air Movement Convection Convection Convection 100 CFM Sq. Ft. Coverage 75 sq. ft. 200 sq. ft. 300 sq. ft. 200 sq. ft. Electrical 120/277V, 60Hz or 220V, 50Hz Construction All units are made of high grade stainless steel Lamp replacement Lamp replacement before the end of effective lamp life is strongly recommended

TB-36-W Installation Template 37.5" 16" TB-36-W mounts via two keyhole slots in the back of the unit. These holes are on 16" center and require # 8 anchor screws. The unit weighs 25 lbs so the wall should be able to hold it. 1.25 5.19" When installing the UV lamp or relamping use cotton gloves or make sure not to touch the lamp. Fingerprints on the germicidal UV lamp will reduce the ultraviolet output. The TB-12-W / 24-W / 36-W should never be installed less than 7 feet from the floor. * ________________ * See installation instructions on next page

CM15 CORNER MOUNTED FIXTURE

CM15 is designed to mount in room corners with two keyhole slots at 7 ft. This fixture incorporates a GML500 lamp and covers 75 - 100 square feet. The CM15 fixture comes complete with an eight-foot power cord and an on/off switch. The louver restricts and concentrates the ultraviolet rays above eye level so personnel can occupy the room while the fixture is on.

Page 24: Commercial UV Products - American Air & Water, Inc Surface Mounted Fixtures UF Utility Fixtures CE Closed End Reflector Fixtures TB & CM In-Room Fixtures RT Recessed Troffers & DB

AMERICAN AIR & WATER®, INC.

American Air & Water®, Inc. * 12 Gibson Drive * Hilton Head Island, SC 29926 Phone: 843-785-8699 * 888-378-4892 * Fax: 843-785-2064 * www.americanairandwater.com

Prices subject to change without notice. All cancelled orders are subject to a 30% restocking fee. Past due invoices are subject to a 1.5% per month interest fee.

24Sep12

TB-W Systems Installation Instructions

TB-W systems are designed for wall mounted installation not less than 7' from the floor. Ceiling Height Fixture Mounting Height 8-9 ft. 7 ft. 10 ft. 7.5 ft. 11 ft. 8 ft. 12 ft. 8.5 ft. The TB units mount via the two key-hole slots in the rear of the unit. These holes require No. 8 anchored screws. The unit weights are respectively 25lb, 23lb and 21lb. Make sure the wall can hold this weight.

TB-36-W Installation Template

TB-24-W Installation Template

TB-12-W Installation Template

Relamp Procedure - Turn off power or pull switch to off position. Lower front louver and remove lamp. Install new lamp and replace louver. When installing the UV lamp use cotton gloves. Fingerprint oil will leave a residue on the germicidal lamp, reducing ultraviolet output.

1.25

16.00 5.875

BACK

27.75

TOP

5.19

1.25

5.008.50

BACK

18.50

TOP

5.19

Page 25: Commercial UV Products - American Air & Water, Inc Surface Mounted Fixtures UF Utility Fixtures CE Closed End Reflector Fixtures TB & CM In-Room Fixtures RT Recessed Troffers & DB

AMERICAN AIR & WATER®, INC.

American Air & Water®, Inc. * 12 Gibson Drive * Hilton Head Island, SC 29926 Phone: 843-785-8699 * 888-378-4892 * Fax: 843-785-2064 * www.americanairandwater.com

Prices subject to change without notice. All cancelled orders are subject to a 30% restocking fee. Past due invoices are subject to a 1.5% per month interest fee.

25Sep12

RAM, TB & CM FIXTURES PRICES

In-room fixtures can be used continuously to reduce air contamination. SBL germicidal UV lamps emitting at 254 nm are effective for 12,000 hours. Lamps will continue to operate after effective operating hours, however 254 nm output is not being emitted. Clean, monitor and check lamps regularly. Please, specify voltage when ordering.

Length Model Description Enclosed stainless steel fixture with two lamps, fans, and filters effective up to 200 square feet

RAM36-2-120 120V, 60Hz with two UV lamps

RAM36-2-230 220V, 50Hz with two UV lamps

FLT065 Filter - 2 required 6¼" x 6¼" x 1¾"

FAN025B Replacement Fan (2 required)

48"

SBL420 Germicidal UV replacement lamp (2 required)

Louvered, wall mounted stainless steel fixture with 1 UV lamp - effective up to 300 square feet

TB-36-W 120V, 60Hz with one UV lamp

TB-36-W/277 277V, 60Hz with one UV lamp

TB-36-W/50 220V, 50Hz with one UV lamp

37.5"

SBL005 Germicidal UV replacement lamp (1) + $60 if coated

Louvered, wall mounted stainless steel fixture with 1 UV lamp - effective up to 200 square feet

TB-24-W 120V, 60Hz with one UV lamp

TB-24-W/277 277V, 60Hz with one UV lamp

TB-24-W/50 220V, 50Hz with one UV lamp

27.75"

SBL325 Germicidal UV replacement lamp (1) + $40 if coated

Louvered, wall mounted stainless steel fixture with 1 UV lamp - effective up to 100 square feet

TB-12-W 120V, 60Hz with one UV lamp

TB-12-W/277 277V, 60Hz with one UV lamp

TB-12-W/50 220V, 50Hz with one UV lamp

18.5"

SBL060 Germicidal UV lamp (1) + $30 coated

Louvered, corner mounted fixture with one UV lamp - effective for 100-150 square feet

CM15 120V, 60Hz

CM15/220 230V, 50Hz

GML500 Germicidal UV lamp with threaded base for CM15

GML505 185nm UV lamp with threaded base (VH Ozone)

14"

GML510 Germicidal UV replacement lamp for CM15/220

Page 26: Commercial UV Products - American Air & Water, Inc Surface Mounted Fixtures UF Utility Fixtures CE Closed End Reflector Fixtures TB & CM In-Room Fixtures RT Recessed Troffers & DB

AMERICAN AIR & WATER®, INC.

American Air & Water®, Inc. * 12 Gibson Drive * Hilton Head Island, SC 29926 Phone: 843-785-8699 * 888-378-4892 * Fax: 843-785-2064 * www.americanairandwater.com

Prices subject to change without notice. All cancelled orders are subject to a 30% restocking fee. Past due invoices are subject to a 1.5% per month interest fee.

26Sep12

MRS MOBILE ROOM STERILIZERS SPECS & PRICES

Model MRS3684P These mobile 8-lamp UV sterilizers feature 2-minute "ON" delay and 24-hour timer for total room irradiation. They are designed for operating rooms, sterile areas, laboratories, unoccupied patient rooms, clean rooms and all other applications where permanent fixtures are not practical. Each unit is equipped with casters for maximum portability. Dimensions - 20”L x 20”W x 48”H

Installation Instructions: These units are shipped assembled and wired for 120V, 60Hz operation. The only procedure necessary is installation of the eight 4-pin GML100 germicidal lamps. To install the lamps remove the top thumb screw and slide the lamp into 4-pin connector. Use gloves when touching the lamp. If fingerprints get on the lamp, clean the lamp with denatured alcohol prior to operation. General Operation: 1. Position unit in center of area to be exposed to UV rays 2. Plug unit into 120V, 60Hz outlet 3. Set 24-hour timer for desired exposure time 4. Push “On” button - 2 minute delay switch 5. Leave area or utilize protective glasses. Avoid exposure to direct or reflected UV light 6. Check and clean lamps regularly - annual replacement required if used continuously - 12,000 hours rated life.

Model Description

Mobile Room sterilizer with 24 hour timer, 2-minute "ON" delay, casters, and handle (20"L x 20"W x 48"H)

MRS3684P Eight GML100 lamps 120V, 60Hz

MRS3684P/220 Eight GML100 lamps 220V, 50/60Hz

MRS3684P/SS Stainless steel Mobile unit with 8 GML100 lamps 120V

GML100 Replacement lamp

TXG015B Replacement ballast Warning: Care should be taken to insure that personnel are not exposed to direct or reflected UV light. Suitable eye and skin protection should be employed when lamp is in operation. Before cleaning or relamping, always turn the power OFF.

Page 27: Commercial UV Products - American Air & Water, Inc Surface Mounted Fixtures UF Utility Fixtures CE Closed End Reflector Fixtures TB & CM In-Room Fixtures RT Recessed Troffers & DB

AMERICAN AIR & WATER®, INC.

American Air & Water®, Inc. * 12 Gibson Drive * Hilton Head Island, SC 29926 Phone: 843-785-8699 * 888-378-4892 * Fax: 843-785-2064 * www.americanairandwater.com

Prices subject to change without notice. All cancelled orders are subject to a 30% restocking fee. Past due invoices are subject to a 1.5% per month interest fee.

27Sep12

RT RECESSED TROFFERS

These germicidal ultraviolet fixtures are constructed of die-formed, one-piece steel and highly reflective aluminum. They are manufactured to meet hospital, pharmaceutical, clean room and laboratory ultraviolet requirements. Two models are available, with four germicidal lamps or a germicidal/ illuminating combination using fluorescent and germicidal lamps.

Model Recessed Troffer fixture

RT-2G/2CWE For "drop-in" grid ceiling 2 GML005 & 2 F30T12, 4’ L x 2’ W x 4¼” D - specify voltage RT-2G/2CWM For plaster ceiling 2 GML005 & 2 F30T12, 4’ L x 2’ W x 4¼” D - specify voltage RT-36-2G E For "drop-in" grid ceiling (2) GML005, 4’ L x 2’ W x 4¼” D - specify voltage RT-36-2G M For plaster ceiling (2) GML005, 4’ L x 2’ W x 4¼” D - specify voltage RT-36-4G E For "drop-in" grid ceiling (4) GML005, 4’ L x 2’ W x 4¼” D - specify voltage RT-36-4G M For plaster ceiling (4) GML005, 4’ L x 2’ W x 4¼” D - specify voltage RT-36-2GE-1x4 For "drop-in" grid ceiling (2) GML005, 4’ L x 1’ W - specify voltage Installation Guidelines Ceiling height up to 9.5' - One RT-36-2G per 75sq. ft. or one RT-36-4G per 125sq. ft. fixtures required. Ceiling height 9.5' to 11' - One RT-36-2G per 50sq. ft. or one RT-36-4G per 100sq. ft. fixtures required. Ceiling height 11' to 14' - One RT-36-2G per 40sq. ft. or one RT-36-4G per 70sq. ft. fixtures required. Note: Install RT-362G/2CW as RT-36-2G

DB GERMICIDAL UV DOOR BARRIER

DB models are fabricated of heavy gauge electro-welded steel with white enamel finishing. By creating a curtain of UV rays, these fixtures provide effective control of airborne microbes between areas. It confines the germicidal energy to a narrow beam, providing full coverage of a 3-foot doorway. Larger openings require multiple fixtures. The UV lamp is positioned behind louvers for personnel safety. Complete with 8' power cord, pull chain switch, GML005 UV lamp effective for 12,000 hours. Ready surface installation possible with "keyhole" slots, as well as additional screw holes in back mounting plate. Louvers remove for easy lamp maintenance with fixture in place. Electrical specifications: 39W, 118V, 60Hz. Also available: 220V, 50Hz or 277V, 60Hz.

Model Dimensions & Voltage

DB-36 36⅞" L x 7" H x 4" D, Multi-volt

GML005 Replacement lamp

TXG010B Replacement ballast Warning: Before cleaning or relamping, always turn power OFF.

Page 28: Commercial UV Products - American Air & Water, Inc Surface Mounted Fixtures UF Utility Fixtures CE Closed End Reflector Fixtures TB & CM In-Room Fixtures RT Recessed Troffers & DB

AMERICAN AIR & WATER®, INC.

American Air & Water®, Inc. * 12 Gibson Drive * Hilton Head Island, SC 29926 Phone: 843-785-8699 * 888-378-4892 * Fax: 843-785-2064 * www.americanairandwater.com

Prices subject to change without notice. All cancelled orders are subject to a 30% restocking fee. Past due invoices are subject to a 1.5% per month interest fee.

28Sep12

UV LAMPS SPECS & PRICES

Length Model Description Type* Diameter/Base UVC Output Watts

UV µW/cm²

@1m

GML370 Hot Cathode PL-S9W/TUV PL-S / G-23 2.4 GML180 Hot Cathode G 4T5 T5/mini bi-pin 0.5 5.4 6" GML170 Hot Cathode OZ4T5 T5/mini bi-pin 0.5 5.4 GML195 Hot Cathode G 6T5 T5/mini bi-pin 1.0 11

9" GML190 Hot Cathode OZ 6T5 T5/mini bi-pin 1.1 11 GML205 Hot Cathode G 8T5 T5/mini bi-pin 1.6 17 GML125 Slimline G12T5½L/BP T5/mini bi-pin 6.0 66 GML075 Slimline G12T5½VH/BP T5/mini bi-pin 6.0 66

12"

GML405 High Output GPH357T5L/HO Four-pin 8.5 92 UVHOAL300AV/14 High Output UV Bulb HO Four-pin 12 106

14" AAWHO/14 High Output Custom Four-pin 12 106

GML020 Cold Cathode 782 L 10 T5/single-pin 2.0 / 2.8 20 / 28 GML120 Cold Cathode 782 VH 10 T5/single-pin 2.0 / 2.8 20 / 28 GML060 Slimline G10T5½L T5/single-pin 5.3 55 GML350 Slimline G10T5½L-4P T5/four-pin 5.3 55

16"

GML070 Slimline G10T5½VH T5/single-pin 5.3 55 GML430 High Output GSL406T5L/HO Four-pin 10.0 108 GML210 Hot Cathode G15T8 T8/medium bi-pin 3.6 38 GML215 Hot Cathode G25T8 T8/medium bi-pin 5.0 54

18"

GML410 High Output GSL406T5L/HO Single-pin 10.0 100 AAWHO/22 High Output GPH550T5/HO/4 Four-pin 18 174

22" GML225MBP High Output CUSTOM T5 15mm Bi-pin 18 157

GML435 High Output GSL610T5L/HO Four-pin 16.2 175 GML0224/4PNO High Output CUSTOM 15mm Four-pin 20 168 24"

GML0244PO High Output CUSTOM 15mm Four-pin 20 168 26" GML025 Cold Cathode 782 L 20 T5/single-pin 3.9 / 5.5 35 / 52

GML290 Cold Cathode 782 VH 20 T5/single-pin 3.9 / 5.5 35 / 52 GML325 Slimline GSL591L T5/single-pin GML355 Slimline S24T6-4P T5/four-pin

27"

GML415 High Output GSL610T5L/HO Single-pin 16.2 140 30" GML030 Cold Cathode 782 L 25½ T5/single-pin 7.3 75

GML010 Cold Cathode 782 L 30 T5/single-pin 5.2 / 8.3 46 / 73 GML035 Cold Cathode 782 VH 29 T5/mini bi-pin 5.7 / 9.1 50 / 80 GML040 Cold Cathode 782 VH 30 T5/single-pin 5.2 / 8.3 46 / 73 GML220 Hot Cathode G30T8 T8/medium bi-pin 8.3 85 GML005 Slimline G36T6L T5/single-pin 13.8 120 GML100 Slimline G36T6L-4P T5/four-pin 12.7 110 GML090 Slimline G36T6VH T5/single-pin 13.8 120 GML095 Slimline G37T6VH T5/single-pin 15.2 124 GML420 High Output GSL843T5L/HO Single-pin 25 195

36”

GML440 High Output GSL843T5L/HO/4 Four-pin 25 195 GML425 High Output GSL1148T5L/HO Single-pin 36.1 250

48" GML445 High Output GSL1148T5L/HO/4 Four-pin 36.1 250 GML015 Slimline G64T5L T5/single-pin 26.7 190 GML017 High Output GXO64T5L H/O Single-pin 46 370 GML140 Slimline G64T5VH T5/single-pin 26.7 190

64”

GML270 Slimline G64T5L-4P T5/four-pin 26.7 190 *Ozone is negligible unless noted as OZ for high or VH for very high ozone production. Length reflects nominal length with standard lamp holders adding 2" overall length. Additional lamp lengths and types available by request

Page 29: Commercial UV Products - American Air & Water, Inc Surface Mounted Fixtures UF Utility Fixtures CE Closed End Reflector Fixtures TB & CM In-Room Fixtures RT Recessed Troffers & DB

AMERICAN AIR & WATER®, INC.

American Air & Water®, Inc. * 12 Gibson Drive * Hilton Head Island, SC 29926 Phone: 843-785-8699 * 888-378-4892 * Fax: 843-785-2064 * www.americanairandwater.com

Prices subject to change without notice. All cancelled orders are subject to a 30% restocking fee. Past due invoices are subject to a 1.5% per month interest fee.

29Sep12

COLD CATHODE GERMICIDAL UV LAMPS

Cold Cathode Germicidal Lamps are instant-start lamps with a cylindrical cold cathode type of electrode. They are available in several sizes and may be operated either from single lamp transformers or in series trough the medium of high voltage transformers. The combination of Vycor glass tubing, used in most Cold Cathode types, and sturdy electrode construction make lamp life considerably longer than other types of lamps. Good ultraviolet maintenance is provided at lower temperatures and lamp life is unaffected by frequent starts. Although the amount of 2537 Angstrom energy emitted is the same for both high and low ozone lamps, the high ozone lamps use a special Vycor glass which transmits a controlled amount of radiation at 1849 Angstroms, which wavelength produces ozone. Ozone has deodorizing properties and is in itself a bactericidal and fungicidal agent. The Vycor glass Cold Cathode Ultraviolet Germicidal Lamp tube is the most economical type for the majority of general germicidal applications, because of its long life electrode and good glass maintenance.

Type Lamp watts

Lamp current

(MA) UV output watts (1)

Microwatts/ cm² @ 1 meter (1)

Ozone genera tion

(2)

Nominal length inch /

cm (3) Arc length inch / cm

Tube diameter

mm 782 L30 17 / 29 50 / 90 5.2 / 8.3 46 / 73 0 / 0 367/8 / 93.7 283/4 / 73.0 15.8 782 H30 17 / 29 50 / 90 5.2 / 8.3 46 /73 0.2 / 0.3 367/8 / 93.7 283/4 / 73.0 15.8 (5) 782 VH29 17 / 29 50 / 90 5.7 / 9.1 50 / 80 0.1 / 1.5 36 / 91.4 277/8 / 70.8 15.8 (4) 782 L25½ 34 122 7.3 75 0 30¼ / 76.9 25½ / 64.8 15.8 782 L20 14 / 24 55 / 90 3.9 / 5.5 35 / 52 0 / 0 267/8 / 68.3 183/4 / 47.6 15.8 782 H20 14 / 24 55 / 90 3.9 / 5.5 35 / 52 0.13 / 0.2 267/8 / 68.3 183/4 / 47.6 15.8 (5) GCC 369N 9 / 14.7 55 / 90 1.6 / 2.4 16 / 23.7 0 / 0 171/8 / 43.5 9 / 22.9 15.8 GCC 369H 9 / 14.7 55 / 90 1.6 / 2.4 16 / 23.7 0.13 / 0.2 171/8 / 43.5 9 / 22.9 15.8 782 L10 12 / 20 60 / 90 2.0 / 2.8 20 / 28 0 / 0 167/8 / 42.9 83/4 / 22.2 15.8 782 H10 12 / 20 60 / 90 2.0 / 2.8 20 / 28 0.08 / 0.1 167/8 / 42.9 83/4 / 22.2 15.8 (5)

HOT CATHODE GERMICIDAL UV LAMPS

The Hot Cathode Germicidal Lamps are similar in their operation to the standard fluorescent lamps. The Hot Cathode type operates from a ballast or transformer and requires a device such as the glow switch starter to preheat the electrodes in order to start the lamp. The electrodes, located at the ends of the lamp, are tungsten filaments coated with emission material and, under normal operation, govern the life of the lamp. In view of the fact that the life of the electrodes is shortened by frequent starts, the lamp life is rated according to the number of times the lamp is started, or the burning cycle. Operation at refrigerator temperatures may result in excessive bulb blackening and rapid depreciation in ultraviolet output. Starting of the Hot Cathode Lamp at low temperature is sometimes unreliable and may require special equipment.

Type Lamp watts

Lamp current

(MA) UV output watts (1)

Microwatts/ cm² @ 1 meter (1)

Ozone genera tion

(2)

Nominal length inch /

cm (3) Arc length inch / cm

Tube diameter

mm G 30T8 30 340 8.3 85 0 36 / 91.4 32 / 81.3 25.4 G 25T8 25 600 5 54 0 18 / 45.7 14 / 36.5 25.4 G 15T8 15 310 3.6 38 0 18 / 45.7 14 / 36.5 25.4 G 8T5 8 170 1.6 17 0 12 / 30.5 8½ / 21.6 15.8 OZ 8T5 8 170 1.8 19.5 0.06 12 / 30.5 8½ / 21.6 15.8 G 6T5 6 147 1 11 0 9 / 22.9 15½ / 14 15.8 G 4T5 4 125 0.5 5.4 0 6 / 15.2 2½ / 6.3 15.8 G 4T4/1 4 90 0.7 10 0 41/2 / 11.2 35/16 / 7.8 13.5 GTL/3 4 350 0.1 1.1 0 21/2 / 5.9 1 / 0.95 28.9 1) Approximate 253.7nm output at 100 hours life. 2) Approximate grams/hour, subject to variations due to surrounding conditions. 3) Includes standard lamp holders. Subtract 2¾ (7cm) to obtain actual face lamp length, not including pins. 4) Ozone resistant ceramic base optional. Approximately ¼” shorter than nominal length. 5) Also available in VH version for very high Ozone output.

Page 30: Commercial UV Products - American Air & Water, Inc Surface Mounted Fixtures UF Utility Fixtures CE Closed End Reflector Fixtures TB & CM In-Room Fixtures RT Recessed Troffers & DB

AMERICAN AIR & WATER®, INC.

American Air & Water®, Inc. * 12 Gibson Drive * Hilton Head Island, SC 29926 Phone: 843-785-8699 * 888-378-4892 * Fax: 843-785-2064 * www.americanairandwater.com

Prices subject to change without notice. All cancelled orders are subject to a 30% restocking fee. Past due invoices are subject to a 1.5% per month interest fee.

30Sep12

SLIMLINE GERMICIDAL UV LAMPS The Slimline Ultraviolet Germicidal Lamp is an instant-start lamp, similar to the Slimline fluorescent lamp. The G10T5½, G36T6, G64T5 are available in low, high and very high ozone types. Their lamp life is governed by the electrode life and number of starts. The G36T6 Slimline type is so designed that it may be operated at currents ranging from 120 to 420 milliamperes, depending upon the type of ballast. Use of higher milliampere ballast increases the lamp ultraviolet output. Because of their high initial ultraviolet emission and good maintenance, Slimline Ultraviolet Germicidal Lamps are well adapted for applications such as air-cooling and heating systems, conveyor lines, water sterilization, and other applications which require high intensity. Type Lamp

watts Lamp

current (MA)

UV output watts (1)

Microwatts/ cm² @ 1 meter (1)

Ozone genera tion (2)

Nominal length inch / cm (3)

Arc length inch / cm

Tube diameter

mm G10T5½L 16 400 5.3 55 0 167/8 / 42.9 107/8 / 27.6 15.8 G10T5½H 16 400 5.3 55 0.21 167/8 / 42.9 107/8 / 27.6 15.8 G10T5½VH 16 400 5.3 55 0.75 167/8 / 42.9 107/8 / 27.6 15.8 (4) G12T5½L 22 400 6.0 66 0 12 / 30.5 8.5 / 21.6 15.8 G12T5½VH 22 400 6.0 66 0.90 12 / 30.5 8.5 / 21.6 15.8 (4) G36T6L 39 425 13.8 120 0 36 / 91.4 30 / 76.2 15.8 G36T6VH 39 425 13.8 120 1.4 36 / 91.4 30 / 76.2 15.8 G36T6 36 425 12.7 110 0 36 / 91.4 30 / 76.2 19 G37T6VH 40 425 15.2 124 1.4 37 / 94 31 / 78.7 15.8 (4) G64T5L 65 425 26.7 190 0 64 / 162.6 58 / 147.3 15.8 G64T5VH 65 425 26.7 190 2.0 64 / 162.6 58 / 147.3 15.8 (4) G64T6L 62 425 25.5 208 0 64 / 162.6 58 / 147.3 19 G67T5L 79 425 25.6 205 0 67.2 / 167.5 61 / 152.5 15.8 G67T5VH 79 425 25.6 205 2.1 67.2 / 167.5 61 / 152.5 15.8 (4)

1. Approximate 253.7nm output at 100 hours life. 2. Approximate grams/hour, subject to variations due to surrounding conditions. 3. Includes standard lamp holders. Subtract 2¾ (7cm) to obtain actual face lamp length, not including pins. All lamps have single

pin base, except G10T5½L and G10T5½VH, which are bi-pin. 4. Ozone resistant ceramic base optional. Approximately ¼” shorter than nominal length.

HIGH OUTPUT GERMICIDAL UV LAMPS

The High Output germicidal UV lamps are specially designed to produce the highest amounts of UV radiation - above 90% of the total rated energy is at 253.7nm. GML HO germicidal lamps are used extensively in air and surface purification applications in the food processing and beverage industries as well as medical and laboratory sterilization applications. These lamps are specifically designed for air and surface irradiation in HVAC systems. They are an ideal choice for mounting close to the coil and drain pan areas to inhibit the growth of mold and mildew in these areas.

TECHNICAL SPECIFICATIONS

Model Lamp watts

Lamp current

mA

UV output Watts ¹

µW/cm²/ sec@ 1m¹

Ozone generation²

Nominal length

inch

Arc length

inch

Tube diameter

mm GML225MBP 56 800 18 157 0 22 19.17 15

GML0224/4PNO 61 800 20 168 0 24 20.83 15

GML0244PO 61 800 20 168 2 24 20.83 15

6) Approximate 253.7nm output at 100 hours life. 7) Approximate grams/hour, subject to variations due to surrounding conditions.

Page 31: Commercial UV Products - American Air & Water, Inc Surface Mounted Fixtures UF Utility Fixtures CE Closed End Reflector Fixtures TB & CM In-Room Fixtures RT Recessed Troffers & DB

AMERICAN AIR & WATER®, INC.

American Air & Water®, Inc. * 12 Gibson Drive * Hilton Head Island, SC 29926 Phone: 843-785-8699 * 888-378-4892 * Fax: 843-785-2064 * www.americanairandwater.com

Prices subject to change without notice. All cancelled orders are subject to a 30% restocking fee. Past due invoices are subject to a 1.5% per month interest fee.

31Sep12

LTC, BT, SC, LTX, STX, LTB, STG, TTG ULTRAVIOLET STERILE CONDITIONER UNITS

Ultraviolet germicidal systems for liquid storage tanks (liquid sugar/syrup and water). Sterile conditioners, vents, blowers, internal and immersion units using one or more germicidal lamps, electrostatic filters and HEPA filters. All units constructed of high grade stainless steel.

Model Description LTC Double-lamp Liquid Tank Conditioners 38" L x 20" H x 12" W, for drop out rates up to 200GPM

Must be mounted on top of tank, 140CFM blower does not allow remote mounting 2 Slimline lamps (GML005), 10" filters - HEPA (FLT035); electrostatic (FLT025), 120V 60Hz *

LTC-2P SSF 3" Female threaded PVC Coupling, single electrostatic filter, 140 CFM blower

LTC2PSSF*/TRI 3" Tri Clamp

LTC2PSSFTRI4 4” Tri Clamp

LTC-2AB SSF 3" Female threaded PVC Coupling, HEPA absolute & two electrostatic filters, 140 CFM blower

LTC2ABSSTRI 3" Tri Clamp

LTC2ABSSTRI/4 4” Tri Clamp * 220V 50Hz systems available upon request

BT Liquid Tank Conditioners, 430 SS, one 14” x 14” Electrostatic pre-filter FLT055 and one 14” x 14” HEPA filter FLT060, Standard 120V/60Hz power supply. Can be mounted directly to the tank or remotely. Provide >30,000µW/cm² of UVC

energy using 4, 6 0r 8 high output, shatterproof lamps SBL420T and include airflow and LED lamp-on indication

BT-4-120 4-lamp conditioner for up to 750GPM dropout rate when top of tank mounted. Up to 400GPM remote mounted (up to 25’ away), 4” Tri Clamp fitting

BT-6-120 6-lamp conditioner for up to 900GPM dropout rate when top of tank mounted. 400 to 800GPM remote mounted (up to 25’ away), 4” Tri Clamp fitting

BT-8-120 8-lamp conditioner for up to 1,500GPM dropout rate when top of tank mounted. 750 to 1,200GPM remote mounted (up to 25’ away), 4” Tri Clamp fitting

SC Four-lamp Liquid Tank Conditioners, 304 stainless steel construction 64" L x 27" H x 17.5" W - floor mounted. For tanks over 20,000 gal

SC4AB/14R4T * see part number selection below

4” Tri Clamp fitting, 14" filters (1 HEPA FLT060 & 2 electrostatic FLT055), 250CFM blower, four 36" 4-pin Slimline GML100 lamps, Air Flow and Lamp-out indication, Various power options available – see voltage code selection below

* Lamp qty. Separator Discharge Dash

SC 4 AB / 14 R 4T ― P3X SC Filter Filter Fitting Voltage Fixture Type Size Code Discharge Fitting Input Power, 1 Phase Input Power, 3 Phase Code Direction Code Size / Type P0Z 120V 60Hz V1Z 208V 60Hz

L Left 4T 4" TRI P1Z 208V 60Hz V2Y 220V 50Hz R Right 4F 4" Flange P2Y 220V 50Hz V3X 230V 60Hz

6T 6" TRI P3X 230V 60Hz V3Y 240V 50Hz 6F 6" Flange V5Y 380V 50Hz V6X 400V 50Hz V6Y 415V 50Hz V7Y 440V 50Hz V8Z 460V 60Hz

Page 32: Commercial UV Products - American Air & Water, Inc Surface Mounted Fixtures UF Utility Fixtures CE Closed End Reflector Fixtures TB & CM In-Room Fixtures RT Recessed Troffers & DB

AMERICAN AIR & WATER®, INC.

American Air & Water®, Inc. * 12 Gibson Drive * Hilton Head Island, SC 29926 Phone: 843-785-8699 * 888-378-4892 * Fax: 843-785-2064 * www.americanairandwater.com

Prices subject to change without notice. All cancelled orders are subject to a 30% restocking fee. Past due invoices are subject to a 1.5% per month interest fee.

32Sep12

LTX Tank Vents - 304 stainless steel construction, 10" filters LTX10P SSF Vent with 3" Female threaded PVC Coupling and one electrostatic filter FLT025

LTX10P TRI 3" Tri Clamp

LTX10P TRI4 4” Tri Clamp

LTX10AB SSF Vent with 3" Female threaded PVC Coupling and HEPA absolute filter FLT035 and two electrostatic filters FLT025

LTX10AB TRI 3" Tri Clamp

LTX10AB TRI4 4” Tri Clamp

STX Tank Vents - 304 stainless steel construction, 14" filters (STX vents go with SC4AB/14 units) STX14PSSTRI4 4” Tri Clamp, one electrostatic filter FLT055

STX14ABSSNPT3 3" Female NPT (PVC), one HEPA filter FLT060 and 2 electrostatic filters FLT055

STX14ABSSTRI3 3" Tri clamp, one HEPA filter FLT060 and 2 electrostatic filters FLT055

STX14ABSSTRI4 4” Tri Clamp, one HEPA filter FLT060 and 2 electrostatic filters FLT055

STX14ABSSFLA4 4” 150# Flange, one HEPA filter FLT060 and 2 electrostatic filters FLT055

LTB Tank blower - 304 stainless steel construction, 10" filters LTB10P SSF 60CFM Blower, 3" Female threaded PVC coupling, one electrostatic filter FLT025 LTB10P/SS/TRI 3" Tri Clamp LTB10P/SS/TRI4 4” Tri Clamp

LTB10ABSSF 100CFM Blower, 3" Female threaded PVC coupling, HEPA FLT035 filter & two electrostatic filters FLT025

LTB10ABSS/TRI 3" Tri Clamp LTB10ABSS/TRI4 4” Tri Clamp

STG Internal Tank Fixtures 17" or 37" x 3" x 2" units with tube guards STG-10-SL One lamp 17" fixture with slimline GML060 lamp and tube guard STG-36 One lamp 37" fixture with slimline GML005 lamp and tube guard STG-36-2 Two lamp 37" fixture with slimline GML005 lamps and two tube guards

TTG Immersion Unit with quartz sleeve and tube guard (13-3/4" L x 3" W plus insertion depth listed) TTG-10-4P One lamp 18" unit with slimline GML350 lamp TTG-24-4P One lamp 27" unit with slimline GML355 lamp TTG-36-4P One lamp 36" unit with slimline GML100 lamp TTG-64-4P One lamp 64" unit with slimline GML270 lamp

OPTIONS

Part # Description AF-100 Air flow indicator - indicates clogged filters(s) or motor failure EL/HV TG Tube guard - lamp out indicator Coating Shatterproof coating for GML005 or GML100 (per lamp) SS10 Rain / Sun screen for 10" filters SS14 Rain / Sun screen for 14" filters See next page for Replacement Lamps, Filters and Parts

Page 33: Commercial UV Products - American Air & Water, Inc Surface Mounted Fixtures UF Utility Fixtures CE Closed End Reflector Fixtures TB & CM In-Room Fixtures RT Recessed Troffers & DB

AMERICAN AIR & WATER®, INC.

American Air & Water®, Inc. * 12 Gibson Drive * Hilton Head Island, SC 29926 Phone: 843-785-8699 * 888-378-4892 * Fax: 843-785-2064 * www.americanairandwater.com

Prices subject to change without notice. All cancelled orders are subject to a 30% restocking fee. Past due invoices are subject to a 1.5% per month interest fee.

33Sep12

REPLACEMENT UV LAMPS, FILTERS & PARTS

FLT035 0.3 micron Absolute HEPA filter 10" x 10" x 5⅞" FLT060 0.3 micron Absolute HEPA filter 14" x 14" x 5⅞" FLT025 10 micron electrostatic washable filter 10" x 10" x 1; stainless steel frame FLT055 10 micron electrostatic washable filter 14" x 14" x 1; stainless steel frame SCZ065 60CFM blower for obsolete SC-1P units, 120V 60Hz SCZ070B SC-1AB, SC-2AB, SC-2P, STB10AB, STB10P 100CFM blower SCZ075B 140CFM blower for all LTC units – 120V 60Hz SCZ145B 140CFM blower for all LTC units – 220V 50Hz SCZ151 SC-4-AB 250CFM blower - specify right or left discharge LHD070 Lamp holder for all LTC units (one set required per lamp) LHD105 4-pin lamp holder for SC4 units TXG015B Ballast for 2 GML005 or GML100 UV lamps – 110/277V 50/60Hz TXG010B Ballast for 1 GML005 or GML100 UV lamp – 110/277V 50/60Hz GML005 UV Lamp for all LTC units GML005T Shatterproof coated lamp SBL420T Shatterproof coated lamp for all BT units GML100 UV Lamp for SC4 and TTG-36-4P GML100T Shatterproof coated lamp for SC4 GML350 Replacement lamp for TTG-10-4P GML355 Replacement lamp for TTG-24-4P GML270 Replacement lamp for TTG-64-4P TXG030B Ballast for for TTG-10, 24 and 36 TXG025 Ballast for for TTG-64 (120V/60Hz)

Quartz Sleeves for TTG units TTG045 18" quartz sleeve -TTG-10 - flair/closed one end (35 x38 mm) TTG050 27" quartz sleeve (TTG-24) - flair/closed one end (35 x38 mm) TTG055 36" quartz sleeve (TTG-36) - flair/closed one end (35 x38 mm) TTG060 64" quartz sleeve (TTG-64) - flair/closed one end (35 x38 mm)

Page 34: Commercial UV Products - American Air & Water, Inc Surface Mounted Fixtures UF Utility Fixtures CE Closed End Reflector Fixtures TB & CM In-Room Fixtures RT Recessed Troffers & DB

AMERICAN AIR & WATER®, INC.

American Air & Water®, Inc. * 12 Gibson Drive * Hilton Head Island, SC 29926 Phone: 843-785-8699 * 888-378-4892 * Fax: 843-785-2064 * www.americanairandwater.com

Prices subject to change without notice. All cancelled orders are subject to a 30% restocking fee. Past due invoices are subject to a 1.5% per month interest fee.

34Sep12

UV SAFETY EQUIPMENT, UV MONITORS, QUARTZ SLEEVES AND BLACKLIGHT LAMPS

Safety precautions must be used. Quartz sleeves are available and offer protection for UV lamps. Black light energy is at the 365nm range - BLB lamps have a filter and BL is a blacklight lamp without filter.

Model Description SAF005 Safety goggles - Ultra-gog 300 SAF010 Safety glasses -Ultra-spec 100 SAF020 Safety goggles with visor – Visor-gogs SAF015 Face mask - Ultra-shield 200 SAF030 Safety lotion - Solbar UV absorbing cream. Two 12oz tubes UVM001-120 Narrow Band UV Monitor UVM Narrow Band UV Monitor with Stainless Steel Enclosure TC Thermistor - temperature control TM LCD temperature monitor with multiple shut-offs

Model Description QSZ050 Quartz Sleeves 10-1/2" closed one end QSZ025 Quartz Sleeves 12-3/4" closed one end QSZ045 Quartz Sleeves 18-1/2" closed one end QSZ065 Quartz Sleeves 18" open both ends (20.5 x 465 mm) QSZ055 Quartz Sleeves 31-1/2" closed one end (22x24.5 mm) QSZ005 Quartz Sleeves 32-3/4" open both ends (22x.24.5 mm) QSZ040 Quartz Sleeves 34-1/2" open both ends (22x24.5 mm) QSZ035 Quartz Sleeves 34" open both ends (22x24.5 mm) QSZ020 Quartz Sleeves 35.1" closed end (P245) QSZ030 Quartz Sleeves 36" open both ends (22x24.5 mm) QSZ015 Quartz Sleeves 60-5/8" open both ends (22x24.5 mm) QSZ060 Quartz Sleeves 63-1/2" closed one end (22x24.613 mm)

Length Model Description Type Diameter/Base

BLL010 Black light - no filter/white F4T5 BL T5/mini bi-pin 6"

BLL015 Black light - filter/blue F4T5 BLB T5/mini bi-pin BLL020 Black light - no filter/white F6T5 BL T5/mini bi-pin

8" BLL025 Black light - filter/blue F6T5 BLB T5/mini bi-pin BLL030 Black light - no filter/white F8T5BL T5/mini bi-pin

12" BLL035 Black light - filter/blue F8T5 BLB T5/mini bi-pin BLL040 Black light - no filter/white F15T5 BL T5/medium bi-pin

18" BLL045 Black light - filter/blue F15T5 BLB T5/medium bi-pin BLL050 Black light - no filter/white F20T12 BL T12/medium bi-pin

23" BLL055 Black light - filter/blue F20T12 BLB T12/medium bi-pin BLL065 Black light - no filter/white F30T8 BL T8/mmedium bi-pin BLL070 Black light - filter/blue F30T8 BLB T8/medium bi-pin BLL075CW Cool white - fluorescent F30T8CW T8/medium bi-pin

36"

BLL070CW Cool white - fluorescent for RT F30T12CW T12/medium bi-pin BLL080 Black light - no filter/white F40T12 BL T12/medium bi-pin BLL085 Black light - filter/blue F40T12 BLB T12/medium bi-pin 48" BLL097 Cool white - fluorescent F40T12 CW T12/medium bi-pin

Page 35: Commercial UV Products - American Air & Water, Inc Surface Mounted Fixtures UF Utility Fixtures CE Closed End Reflector Fixtures TB & CM In-Room Fixtures RT Recessed Troffers & DB

AMERICAN AIR & WATER®, INC.

American Air & Water®, Inc. * 12 Gibson Drive * Hilton Head Island, SC 29926 Phone: 843-785-8699 * 888-378-4892 * Fax: 843-785-2064 * www.americanairandwater.com

Prices subject to change without notice. All cancelled orders are subject to a 30% restocking fee. Past due invoices are subject to a 1.5% per month interest fee.

35Sep12

Sporicidin Disinfectant and Sterilizing Solution

Sporicidin® Disinfectant Solution is registered by the Environmental Protection Agency. It is also an FDA and OSHA compliant full spectrum disinfectant - bactericidal, virucidal, tuberculocidal, fungicidal - with proven 100% kill. Sporicidin is the best choice for killing mold and mold spores, mold remediation and air duct cleaning. Sporicidin® Disinfectant Solution is EPA listed as Flu and MRSA disinfectant providing 100% kill of pathogenic and odor-causing microorganisms.

Catalog # Sporicidin® Product Description Price Sporicidin® Disinfectant Solution and Pump Spray

RE-55GAL Disinfectant Solution and Presoak in 55 gallon Drum $1,331.25

RE-1284C Gallon Bottle Disinfectant Solution and Presoak - 4 bottles per case $124.00 case $31.00 bottle

PS-2212C 22 oz. Pump Spray - 12 bottles per case $130.80 case $10.90 bottle

Sporicidin® Disinfectant Towelettes

Can-18012C Disinfectant Towelettes in pop-up canister (5" x 8") 180 towelettes per canister, 12 canisters per case

$132.40 case $11.03 canister

ST50-600 Disinfectant Towelettes, Individually Wrapped (5" x 8") 50 per box, 12 boxes per case /600 towelletes per case/

$277.20 case $23.10 box

Sporicidin® Enzyme Mold Cleaner

ENZ-3212 Case of 12 Quart (32oz / 946ml) bottles of mold cleaner concentrate. One Quart Makes 16 Gallons of mold cleaner. $409.80 case

ENZ-3212Q Quart (32oz / 946ml) bottle of concentrate. One Quart Makes 16 Gallons of mold cleaner. $34.15 each

Sporicidin® Sterile Packaged Clean Room Disinfectants GAMMA-

1284C Gallon Disinfectant Solution - ISO 11137 Gamma Irradiated and Double Bagged 4 gallon bottles per case

$197.00 case $49.25ach

Sporicidin® Sterilizing Solution and Indicator Kit

SSS-1284C Sterilizing Solution Gallon Bottle - 4 bottles per case $136.80e $34.20 each

SSS-3216C Quart (32 oz.) Bottle - 4 bottles per box, 4 boxes per case /16 bottles per case/ $251.20 case $62.80 box

$15.70 bottle

PMG-6000 Sporicidin® Indicator Kit - 60 Glutaraldehyde Test Strips, 60 Phenol Test Strips 4 kits per case

$393.20 case $98.30 each

Sporicidin® Enzymatic Cleaner

ENZ-1284 Enzymatic Cleaner Gallon Bottle - 4 bottles per case $191.20 case $47.80 each

Sporicidin® Antimicrobial Lotion Soap

ALS-1282 Antimicrobial Lotion Soap Gallon Bottle - 2 bottles per case $75.60 case $37.80 each

CALS-2416 16 oz. Pump Bottle - 6 bottles per box, 4 boxes per case /24 bottles per case/ $220.80 case $9.20 each

Sporicidin® Antiseptic First Aid Spray

CFA-2402 2 oz. Antiseptic First Aid Spray (carded) - 6 bottles per box, 4 boxes per case /24 bottles per case/

$128.40 case $32.10 box $5.35 each

Sporicidin® Test Kit

SPDN0030 Microbial Test Kit, 2 swabs per kit (carded), 12 kits/case $299.40 case $24.95 kit

Page 36: Commercial UV Products - American Air & Water, Inc Surface Mounted Fixtures UF Utility Fixtures CE Closed End Reflector Fixtures TB & CM In-Room Fixtures RT Recessed Troffers & DB

AMERICAN AIR & WATER®, INC.

American Air & Water®, Inc. * 12 Gibson Drive * Hilton Head Island, SC 29926 Phone: 843-785-8699 * 888-378-4892 * Fax: 843-785-2064 * www.americanairandwater.com

Prices subject to change without notice. All cancelled orders are subject to a 30% restocking fee. Past due invoices are subject to a 1.5% per month interest fee.

36Sep12

Sporicidin Disinfectant is alcohol-free and provides "continuous residual bacteriostatic activity for up to six months". The active ingredient system in Sporicidin® Antimicrobial Lotion Soap is classified by the FDA as a "Health-Care Personnel Handwash," "Wound Cleanser" and "Surgical Scrub". The soap is an effective skin antiseptic and deodorant.

Benefits of Sporicidin® Disinfectant Solution

"Effective against mycotoxin-producing molds, including Stachybotrys, Chaetomium arid Aspergillus" Effective for sewage backflow odors Recommended for misting and fogging to control dust, odors and microbial contamination EPA registered for hospital disinfection and air duct cleaning FDA cleared for disinfection of hospital instruments and equipment OSHA compliance with Bloodborne Pathogens Standard Registered in all 50 states, including California Non-corrosive to surfaces including plastics, latex, vinyl, glass, wood, metal and porcelain Non-flammable, non-staining, alcohol-free Does not contain harsh chemicals like bleach, o-phenylphenol and chlorine dioxide nor oxidizing agents Reduces the hazards of cross-contamination Mildly alkaline (pH 7.5) No special shipping or disposal requirements

Sporicidin has been used in hospitals and pharmaceutical clean rooms since 1978 for disinfection of instruments, equipment and environmental surfaces. It is currently being used "on a regular basis" by the Pentagon as "a valuable tool in providing disinfection to our environmental surfaces" and by NASA on the International Space Station.

Sporicidin® Applications

Mold remediation for commercial and residential buildings Cleaning HVAC air ducts Sewage cleanup Water and flood damage restoration Decontaminating and deodorizing carpet, upholstery, furniture, books and art - kills the microorganisms

that cause odors Decontaminating respirators, personal protective equipment and restoration equipment Biohazard and crime scene cleanup Misting and dust suppression Disinfection of instruments, equipment and surfaces in hospitals, medical and dental offices and

pharmaceutical clean rooms - Sporicidin® has been the medical disinfectant of choice since 1978 Recommended for use on wood, glass, tile, rubber, vinyl, plastics and metals, Sporicidin® does not

inhibit the adhesion of paint

Sporicidin® Disinfectant Solution and Spray

RE-1284C PS-2212C FDA/EPA registered for disinfection of medical / dental devices, equipment and surfaces. Also, recommended for presoaking

semi-critical and critical surgical devices prior to terminal sterilization. EPA registered to kill mold.

Sporicidin® Sterilizing and High Level Disinfectant Solution

SSS-1284 SSS-3216 Lowest level of glutaraldehyde (1%) accepted by FDA to achieve sterilization. High level disinfection in 20 minutes.

Page 37: Commercial UV Products - American Air & Water, Inc Surface Mounted Fixtures UF Utility Fixtures CE Closed End Reflector Fixtures TB & CM In-Room Fixtures RT Recessed Troffers & DB

AMERICAN AIR & WATER®, INC.

American Air & Water®, Inc. * 12 Gibson Drive * Hilton Head Island, SC 29926 Phone: 843-785-8699 * 888-378-4892 * Fax: 843-785-2064 * www.americanairandwater.com

Prices subject to change without notice. All cancelled orders are subject to a 30% restocking fee. Past due invoices are subject to a 1.5% per month interest fee.

37Sep12

Sporicidin® Enzymatic Cleaner

ENZ-1284 Recommended as an instrument presoak in ultrasonic units, automatic washers, evacuation systems and trays. A blended enzyme system which loosens and removes dried

debris, blood, protein and mucin deposits.

Sporicidin® Antimicrobial Lotion Soap

ALS-1282 CALS-2416 For repeated use daily on hands and entire body in hospitals, operating and patient rooms, medical and dental offices, clean

rooms, clinics, labs, nursing homes, schools, public facilities, restaurants and the home. 99.9% kill of pathogenic and odor-causing organisms.

Sporicidin® Gamma Irradiated Disinfectant

GAMMA-1284C

Recommended for pharmaceutical, biotech, and medical device manufacturing facilities. Contains no alcohol. No rotation necessary. Double-

bagged and gamma irradiated according to ISO -11137 medical device sterilization protocols.

Sporicidin® Disinfectant Towelettes - Canister and Individually Wrapped

Can-18012C ST50-600 The only disinfectant wipe accepted by FDA, to date for the disinfection of medical/dental devices, ultra sound probes, electrodes, etc. and surfaces in

offices and operating, emergency and patient rooms. Available in canister (180 wipes/canister) and individual towelettes (12”x 12”) and (5”x 8”). Sporicidin® Antiseptic and Anesthetic First-Aid Spray CFA-2402

Promotes healing while it relieves pain and soreness of minor cuts, burns, scrapes, insect bites and skin irritations. 100% kill of pathogenic organisms, including the Athlete’s Foot fungus.

The Environmental Protection Agency (EPA) categorizes Sporicidin® as a Very Low Toxicity product for oral, dermal or inhalation effects and skin irritation. EPA categorizes Sporicidin® in the Low Toxicity category for eye irritation. Sporicidin Beats Bleach Sporicidin Beats Bleach: According to researchers at the University of Maryland, Sporicidin Disinfectant Solution "is more effective than household bleach in controlling common mold fungi found in building materials, including Stachybotrys chartarum, Chaetomium globosum and Aspergillus niger (black mold). These comments came from study leader George Bean, Ph.D. a professor in the Department of Cell Biology and Molecular Genetics at the university. ...The findings are significant, "because they update recommendations from the Centers for Disease Control and Prevention (CDC) which has recommended that most molds can be treated by cleaning with bleach and water". Sporicidin was also highly rated in the study for its residual effect. The EPA registered disinfectant has gained popularity in the remediation market... Indoor Environment Connections

Page 38: Commercial UV Products - American Air & Water, Inc Surface Mounted Fixtures UF Utility Fixtures CE Closed End Reflector Fixtures TB & CM In-Room Fixtures RT Recessed Troffers & DB

AMERICAN AIR & WATER®, INC.

American Air & Water®, Inc. * 12 Gibson Drive * Hilton Head Island, SC 29926 Phone: 843-785-8699 * 888-378-4892 * Fax: 843-785-2064 * www.americanairandwater.com

Prices subject to change without notice.

38

AA&W FOGGERS & SPRAYERS

FOGGER

• Variable flow from ultra low volume (ULV) to light mist • 2-stage motor for good reliability • Adjustable flow from 0-18 oz/min • Nozzle mounted on 48" hose • 1.5 gallon capacity • Easy to use yet durable

The Flex-A-Lite Fogger provides the operator with the widest range of options available for cold fog applications. The nozzle, attached to the flex hose, allows the user to easily direct the fog in, under and at objects. The convenient flow adjustment knob located at the nozzle enables the operator of the fogger to change the liquid flow rate being dispensed.

The operator can adjust the liquid flow to dispense materials at average droplet sizes under 20 microns (water based chemicals at room temperature). Droplets of this size remain suspended in air for extended period of time and are used primarily for insecticide applications to control flying insects.

Droplet size will increase as the liquid flow rate is increased and will average approximately 80 microns when the liquid flow is adjusted for maximum output. Larger droplets are dispersed by air flow and can settle on surfaces. This characteristic makes them useful for applying disinfectant, deodorizers and chemicals used for coating the insides of air ducts or other surfaces.

SPRAYER

• Great for a wide variety of applications • 3 gallon heavy duty tank • Electric pump is self contained in unit • Wide variety of Spray Tips available • 25' Recoiling hose (other models available) • All brass wand construction • On demand pump (up to 50 PSI) • Optional upholstery kit • Easy to use yet durable

The AA&W Electric Sprayer is ideal for a wide variety of applications including surface disinfection, air duct cleaning and coil spraying and cleaning. The Sprayer can be used to apply Sporicidin or a different disinfectant to various surfaces and areas which are difficult to access.

PRICING

Model Wholesale Prices

AA&W Fogger $369

AA&W Sprayer $429

Page 39: Commercial UV Products - American Air & Water, Inc Surface Mounted Fixtures UF Utility Fixtures CE Closed End Reflector Fixtures TB & CM In-Room Fixtures RT Recessed Troffers & DB

AMERICAN AIR & WATER®, INC.

American Air & Water®, Inc. * 12 Gibson Drive * Hilton Head Island, SC 29926 Phone: 843-785-8699 * 888-378-4892 * Fax: 843-785-2064 * www.americanairandwater.com

Prices subject to change without notice.

39

DETERMINING ULTRAVIOLET INTENSITIES USING GERMICIDAL UV LAMPS

To determine the intensity of ultraviolet on a surface at various distances from a germicidal ultraviolet lamp multiply the radiant energy [shown in microwatts per square centimeter per second at one meter] by the intensity factor as shown in table below. The intensity factor table may be used for all germicidal lamps:

Distance from Lamp 2” 3” 4” 6” 8” 10” 12” 14” 18”

Intensity Factor 32.3 22.8 18.6 12.9 9.85 7.94 6.48 5.35 3.6

Distance from Lamp 24” 36” 39.37” (1 meter) 48” 60” 80” 100” 120”

Intensity Factor 2.33 1.22 1.00 0.681 0.452 0.256 0.169 0.115

Example: The ultraviolet intensity produced by one 782L30 (GML010) germicidal lamp at room temperature is 73µW/cm² /sec @ 1m. The intensity factor at 24 inches is 2.33 as shown in table above. Multiply the rated intensity of the lamp 73 by the intensity factor for 24 inches - 2.33:

73 x 2.33 = 170.09µW/cm² /sec @ at 24”

In like manner, the ultraviolet intensity produced by one G36T6L (GML005) germicidal ultraviolet lamp at 120 inches is: 120 x .115 = 13.8µW/cm² /sec at 120” The intensity factors listed were determined through testing using a click meter and a bare germicidal ultraviolet lamp with no reflector. If a parabolic, specular aluminum reflector is used in conjunction with the lamp, the intensity will be increased many times, depending upon the design and the efficiency of the reflector. The intensity factor table provides an easy method for quickly calculating ultraviolet intensities within ten percent accuracy. A UV radiometer for 254nm wavelength can be used for additional measurements. Lamp intensity and exposure time are the main considerations for the effectiveness of UV destruction or inactivation of microorganism. The formula below can be used to calculate exposure time. Intensity required depends on the type of lamp, the microorganism being eliminated and the distance from the lamp. Example: For 100% destruction of green mold spores (penicillium roqueforti) a UV dose of 26,400 microwatt/seconds per square centimeter is needed. A GML005 germicidal ultraviolet lamp has UV output of 120µW/cm² /sec @ 1 meter. With two lamps the intensity doubles to 240µW/cm² /sec @ 1m At 3” from surface the intensity factor is 22.8.. The calculation is: 240 x 22.8 = 5,472µW/cm² /sec @ 3" 26,400 / 5,472 = 4.82 seconds. Approximately 5 seconds are needed for two GML005 lamps at 3” to deliver a UV dose of 26,400 microwatts/ cm² and eradicate the green mold spores.

Page 40: Commercial UV Products - American Air & Water, Inc Surface Mounted Fixtures UF Utility Fixtures CE Closed End Reflector Fixtures TB & CM In-Room Fixtures RT Recessed Troffers & DB

AMERICAN AIR & WATER®, INC.

American Air & Water®, Inc. * 12 Gibson Drive * Hilton Head Island, SC 29926 Phone: 843-785-8699 * 888-378-4892 * Fax: 843-785-2064 * www.americanairandwater.com

Prices subject to change without notice.

40

DISTRIBUTION OF RADIANT UV ENERGY PRODUCED BY GERMICIDAL LAMPS

The following table gives the radiant energy distribution of germicidal ultraviolet lamps operating under specified test conditions after 100 hours burning.

Energy radiated in microwatts per square centimeter at one meter

UV Lamps 782 L20 782 L10 782 H10

782 L30 782 H30 G30T8 G15T8 G8T5 G36T6L (GML005)

Arc Length 18” 8” 28” 32” 14” 8” 30” Wattage 24 20 29 30 15 8 39 Milliamps 90 90 90 340 310 170 120 200 300 420 Factors*

253.7 28 50 73 85 38 17 70 100 115 120 measure265.2 .854 1.525 2.227 2.592 1.159 .518 2.135 3.05 3.51 3.66 .0305 280.4 .028 .050 .073 .085 .038 .017 .070 .100 .115 .120 .0010 289.4 .039 .070 .102 .119 .053 .024 .098 .140 .161 .170 .0014 296.7 .146 .260 .380 .442 .198 .088 .364 .520 .598 .624 .0052 302.2 .070 .125 .184 .213 .095 .043 .175 .250 .288 .300 .0025 319.9 .549 .980 1.431 1.670 .745 .333 1.372 1.960 2,254 2.352 .0186 365.4 .468 .835 1.219 1.420 .635 .284 1.170 1.670 1.920 2.004 .0167 404.7 .554 .990 1.445 1.680 .752 .336 1.386 1.980 2.277 2.376 .0198 435.9 1.680 3.000 4.380 5.100 2.280 1.020 4.200 6.000 6.900 7.200 .0600 546.1 .916 1.635 2.387 2.780 1.243 .555 2.290 3.720 3.760 3.924 .0327 578.0 .199 .355 .518 .604 .269 .121 .497 .710 .816 .852 .0071

Wav

e le

ngth

in n

anom

eter

s (1

0 nm

= 1

Ang

stro

m)

*The measured UV intensity at 253.7 nanometer units multiplied by these factors will give the intensity at other wavelength. There is a small amount of ultraviolet radiation generated below 200 nanometers, which produces ozone in the air, but the intensity depends upon the type of lamp. No figures are given for this radiation as the amount is very small and the atmosphere rapidly absorbs such energy. For comparison purposes, the transmission at 184.9 nanometer units for the types of glasses used in germicidal ultraviolet lamps is shown below: UV Lamps G30T8, G15T8, G8T5 782L10, 782L20, G36T6L 782H10, 752H30, G36T6H Type of glass 9823 7910 7912 Transmission @ 184.9 nm Negligible .05% .02%

UV REFLECTIVE FACTORS ON VARIOUS SURFACES AT 254NM WAVELENGTH

EXTINCTION DEPTHS AT 254NM WAVELENGT

Material % Reflectance* Material In relation to clear water Aluminum, etched 88 Apple Juice 1.0 Aluminum, foil 73 Beer < 1.3 Aluminum, polished commercial 73 Liquid Sugar 1.0 Chromium 45 Milk – whole, raw < 0.1 Glass 4 Vinegar < 5.0 Nickel 38 Water – concrete cistern < 75 Silver 22 Water – distilled 3,000 Stainless steel 20-30 Water – tap or mains 125 – 180 Tri-plated steel 28 Wine < 2.5 Water paints 10-30 White cotton 30 White oil paint 5-10 White paper 25 White porcelain 5 White wall plaster 40-60 * Values obtained at normal incidence. The percentage reflectance increases rapidly at angles greater than 75%.