B ALL CONSTRUCTION TO COMPLY WITH CANADIANSTANDARDS ASSOCIATION, CURRENT ENERGY CODEAND LOCAL AMMENDMENTS OR REQUIREMENTS.
A ALL MATERIALS ON JOB TO COMPLY WITH FEDERAL ANDSTATE VOC/AIM REGULATIONS.
C ALL FIRE WALL PENETRATIONS SHALL BE SEALED WITHFIRE RATED FOAM SEALANT (BOTH SIDES OF WALL).SEALANT TYPE SHALL BE A COMPATIBLE RATING TOTHE WALL SYSTEMS.
D MAXIMUM CLEAR SPAN HEIGHTS FOR INTERIOR METALSTUDS SHALL BE SUCH THAT DEFLECTION SHALL NOTEXCEED L/360 UNDER A 5 PFS LOAD (CERAMIC TILEFINISHES) AND 1/120 AT ALL OTHER AREAS.
E WHERE REQUIRED BY CODE ALUMINUM VERTICALMULLIONS TO RECEIVE STELL STIFFENER TO ACHIEVEWIND LOAD CAPACITY.
F ALL WOOD FRAMING, BLOCKING, SHEATHING ORBRACING SHALL BE FIRE RETARDANT TREATED.
G DO NOT SCALE THESE DRAWINGS FOR DIMENSIONALINFORMATION. REFER TO DIMENSIONS ON THE FLOORPLANS AND ENLARGED PLANS. IF THERE IS A CONFLICTWITH THE PLAN DIMENSIONS OR AN EXISTING FIELDCONDITION, CONTACT THE ARCHITECT. DIMENSIONSARE GIVEN TO FACE OF FINISH, UNO.
H REFER TO BUILDING ELEVATION DRAWINGS FOR FINISHMATERIAL CALL OUTS AND PAINT REQUIREMENTS.VERIFY COLOR OF MATERIALS NOT SHOWN ON THEDRAWINGS WITH THE ARCHITECT.
J ALL GYPSUM BOARD THROUGHOUT THE PROJECTSHALL BE 5/8" THICK, UNO. (TYPE 'X' IF REQUIRED) USEWATER RESISTANT GYPSUM BOARD AT ALL WETLOCATIONS AND 5/8" FIBER REINFORCED CEMENTBOARD BEHIND ALL WALL TILE.
K GALVANIZE ALL EXPOSED EXTERIOR STEEL.L COORDINATE ALL REQUIRED ELECTRICAL CONDUITS
AND SLEEVES FOR IRRIGATION UNDER SIDEWALKAREAS AT DECORATIVE LIGHT POLES AND PLANTERSWITH MECHANICAL AND ELECTRICAL PLANS.
DATE REVISION1 09/19/2016 ISSUE FOR PERMIT2 10/28/2016 ISSUE FOR CONST.
10/28/2016
APPLICABLE BUILDING CODES & REQULATIONSPROJECT INFORMATION
NATIONAL BUILDING CODE OF CANADA 2015NATIONAL FIRE CODE OF CANADA 2015NATIONAL PLUMBING CODE OF CANADA 2015NATIONAL ENERGY CODE OF CANADA FOR BUILDINGS 2015
Description of Proposed Work:New pre-engineered metal office / warehouse building.
Building Classification (Table 3.1.2.1):Office - Group = D Division = N/AWarehouse - Group = F Division = 2 (medium Hazard)Shell Warehouse - Group = F Division = 3 (low hazard)
Type of Construction (3.2.2.61 & 3.2.2.77):Non-Combustible
Building Area:Office (2 Story)Level 01 - Shell office = 5,000 sf = 464.5 sm Level 02 – Cohen Office = 5,000 sf = 464.5 sm
Warehouse (1 Story) = 20,000 sf = 1,858 sm Storage of furniture = 15,000 sf = 1394 sm Shell warehouse = 5,000 sf = 465 sm
Second level is 13.0’ (3.96 m) above first level
Building Faces (3.2.2.10):One street: 124 GLENCOE DRIVE, MOUNT PEARL, NL, A1N 4S6
Occupant Load:Per NFPA 101 (Table 7.3.1.2)Office = 9.30 sm per occ Floor 1 = 464.5 sm / 9.30 sm per occ = 49.9 occ = 50 occ Floor 2 = 464.5 sm / 9.30 sm per occ = 49.9 occ = 50 occWarehouse = 28.00 sm per occ Furniture = 1,394 sm / 46.5 sm per occ = 29.9 occ = 30 occ Shell = 465 sm / 46.5 sm per occ = 10 occ = 10 occ
Exposed Building Face (3.2.3.1.D and 3.2.3.1.E):Limiting Distance Allowed =Maximum allowable % Unprotected Openings = Group D, F-3 (3.2.3.1.D) = Group F-2 (3.2.3.1.E) = Area of wall = 8,420sf / 782.2sm (s) 3,748sf / 348.2sm (w) 8,310sf / 772sm (n)1,818sf / 169sm (e)Distance to Nearest Building (property line) = 5.01m (s) 15.04m (w) 21.14m (n) 25.38m(e)
Building Serviced with:Fully sprinklered ESFR, wet system
Floor Assembly (3.2.2.61 & 3.2.2.77):Non-Combustible per the following:Group D, up to 2 stories, sprinklered, area no greater than 2,400 sm Floor required to be fire separation – if combustible, not less than 45 min Per Appendix A, a fire separation may or may not have a fire resistance rating - 0 hr rating provided Loadbearing walls, columns required to have fire resistance rating to be not less than 45 min or be non-combustible - 0 hrrating providedGroup F, Division 2, up to 2 stories, sprinklered, area no greater than 4,500 sm Loadbearing walls, columns required to have fire resistance rating to be not less than 45 min or be non-combustible - 0 hrrating provided
Fire Resistance Rating:Ceilings and Walls (3.6.4.3) - N/ALoad Bearing Walls (3.1.7.5) - N/AColumns and Arches (3.1.7.5) - N/A Non combustibleFire Separations Elevator / Lift (3.5.3.1) - required to match floor rating = 0 hr Stair - 45 minMezzanines - N/AFurnace Rooms - N/AElectrical Rooms (3.6.2.1) - N/AFlammable Liquid Storage Rooms - N/A
Occupancy Separation (Table 3.1.3.1):D to F2 = none requiredF2 to F3 = none required
Per 3.1.4.1, the flame spread rating of any exposed surface of foam plastic insulation shall be no more than 500.
Roof Assemblies (3.1.14.2):Non-Combustible metal deck, with rigid insulation above, and metal roof decking
Fire Alarm (3.2.4):Required in a building with an automatic sprinkler system
Building Area Allowance / Type of Construction (3.2.2.61 & 3.2.2.77):Non-Combustible per the following:Group D, up to 2 stories, sprinklered, area no greater than 2,400 sm Floor required to be fire separation – if combustible, not less than 45 min Per Appendix A, a fire separation may or may not have a fire resistance rating Loadbearing walls, columns required to have fire resistance rating to be not less than 45 min or be non-combustible
Group F, Division 2, up to 2 stories, sprinklered, area no greater than 4,500 sm Loadbearing walls, columns required to have fire resistance rating to be not less than 45 min or be non-combustible
Standpipes not required per 3.2.5.8
Exits (3.4):Number: 2 required, separated by ½ the diagonal of the floor. Travel distance no more than 40m in groupD, 45m in group FExit Width: Stair = 8mm per occ = 50 occ x 8mm per occ = 400 mm (15”) = 900mm min = (35.4”) =1219mm (48”) provided Doors = 800mm min (31.5”) = 914mm (36”) provided
Headroom Clearance (3.4.3.4)2050 mm = 80.7” (stairs / corridors)2030 mm = 79.9” (doors)
Fire Separation of Exits (3.4.4.1):
Stairs (3.4.6.1 – 3.4.6.8, 3.4.7.5 – 3.4.7.7):
Roof:Combustible Roofing (3.1.5.3) Combustible roofing w/ A, B or C classification per 3.1.15 is permitted on a noncombustible building.
Restrooms:Water Closets (3.7.2.2.B & 3.7.2.2.C):Office = 9.30 sm per occ Floor 2 = 464.5 sm / 9.30 sm per occ = 49.9 occ = 50 occ = 2total (1 men’s, 1 women’s)Warehouse = 28.00 sm per occ Furniture = 1,394 sm / 46.5 sm per occ = 29.9 occ = 30 occ = 4total (2 men’s, 2 women’s)
Lavatories (3.7.2.3):1 lavatory required in a room with a water closet or urinal
A. WHERE A BUILDING IS EQUIPPED THROUGHOUT WITHAN AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCEWITH SECTION 3.4, THE SEPARATION DISTANCE OF THEEXIT DOORS OR EXIT ACCESS DOORWAYS SHALL NOTBE LESS THAN ONE-THIRD OF THE LENGTH OF THEMAXIMUM OVERALL DIMENSION OF THE AREA SERVED.
B. MAXIMUM TRAVEL DISTANCE FOR GROUP DOCCUPANCY = 40m.
C. MAXIMUM TRAVEL DISTANCE FOR GROUP FOCCUPANCY = 45m.
D. REFER TO SHEET A601 FOR PARTITION TYPES.E. REFER TO A400 SERIES SHEETS FOR ENLARGED PLANS.
A. WHERE A BUILDING IS EQUIPPED THROUGHOUT WITHAN AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCEWITH SECTION 3.4, THE SEPARATION DISTANCE OF THEEXIT DOORS OR EXIT ACCESS DOORWAYS SHALL NOTBE LESS THAN ONE-THIRD OF THE LENGTH OF THEMAXIMUM OVERALL DIMENSION OF THE AREA SERVED.
B. MAXIMUM TRAVEL DISTANCE FOR GROUP DOCCUPANCY = 40m.
C. MAXIMUM TRAVEL DISTANCE FOR GROUP FOCCUPANCY = 45m.
D. REFER TO SHEET A601 FOR PARTITION TYPES.E. REFER TO A400 SERIES SHEETS FOR ENLARGED PLANS.
1. EVERY DOORWAY THAT IS LOCATED IN A BARRIER-FREE PATH OFTRAVEL SHALL HAVE A CLEAR WIDTH NOT LESS THAN 800 mmm WHENTHE DOOR IS IN THE OPEN POSITION.
2. DOORWAYS IN A PATH OF TRAVEL TO AT LEAST ONE FULL BATHROOMWITHIN A SUITE OF A RESIDENTIAL OCCUPANCY SHALL HAVE A CLEARWIDTH NOT LESS THAN 800 mm WHEN THE DOORS ARE OPEN.
3. A THRESHOLD FOR A DOORWAY REFERRED TO IN SENTENCES (1) OR(2) SHALL BE NOT MORE THAN 13 mm HIGHER THAN THE FINISHEDFLOOR SURFACE AND SHALL BE BEVELLED TO FACILITATE THEPASSAGE OF WHEELCHAIRS.
4. EXCEPT AS PERMITTED IN SENTENCE (8), AND EXCEPT FOR DOORSWITH POWER DOOR OPERATOR, A CLOSER FOR A DOOR IN ABARRIER-FREE PATH OF TRAVEL SHALL BE DESIGNED TO PERMIT THEDOOR TO OPEN WHEN THE FORCE APPLIED TO THE HANDLE, PUSHPLATE OR LATCH-RELEASING DEVICE IS NOT MORE THAN a) 38 N IN THECASE OF AN EXTERIOR DOOR, OR b) 22 N IN THE CASE OF INTERIORDOOR.
5. EXCEPT FOR A DOOR AT THE ENTRANCE TO DWELLING UNITS, ACLOSER FOR AN INTERIOR DOOR IN A BARRIER-FREE PATH OF TRAVELSHALL HAVE A CLOSING PERIOD OF NOT LESS THAN 3 SECONDSMEASURED FROM WHEN THE DOOR IS IN AN OPEN POSITION OF 70° TOTHE DOORWAY, TO WHEN THE DOOR REACHES A POINT 75 mm FROMTHE CLOSED POSITION, MEASURED FROM THE LEADING EDGE OF THELATCH SIDE OF THE DOOR.
6. UNLESS EQUIPPED WITH A POWER DOOR OPERATOR, A DOOR IN ABARRIER-FREE PATH OF TRAVEL SHALL HAVE A CLEAR SPACE ON THELATCH SIDE EXTENDING THE HEIGHT OF THE DOORWAY AND NOT LESSTHAN, a) 600 mm BEYOND THE EDGE OF THE DOOR OPENING IF THEDOOR SWINGS TOWARD THE APPROACH SIDE, AND b) 300 mm BEYONDTHE EDGE OF THE DOOR OPENING IF THE DOOR SWINGS AWAY FROMTHE APPROACH SIDE.
7 A VESTIBULE LOCATED IN A BARRIER-FREE PATH OF TRAVEL SHALL BEARRANGED TO ALLOW THE MOVEMENT OF WHEELCHAIRS BETWEENDOORS AND SHALL PROVIDE A DISTANCE BETWEEN TWO DOORS INSERIES OF NOT LESS THAN 1 200 mm PLUS THE WIDTH OF ANY DOORTHAT SWINGS INTO THE SPACE IN THE PATH OF TRAVEL FROM ONEDOOR TO ANOTHER.
8 EXCEPT AS PROVIDE IN CLAUSE 3.8.3.4(1)(c), THE FLOOR SURFACE ONEACH SIDE OF A DOOR IN A BARRIER-FREE PATH OF TRAVEL SHALL BELEVEL WITHIN A RECTANGULAR AREA a) AS WIDE AS THE DOOR PLUSTHE CLEARANCE REQUIRED ON THE LATCH SIDE BY SENTENCE3.8.3.3.(10), AND b) WHOSE DIMENSION PERPENDICULAR TO THECLOSED DOOR IS NOT LESS THAN THE WIDTH OF THE BARRIER-FREEPATH OF TRAVEL BUT NOT EXCEED 1 500 mm.
ACCESSIBLE DOOR SHALL COMPLY WITH THE FOLLOWING: WATER CLOSET:
LAVATORIES:1. a) BARRIER-FREE WASHROOM SHALL BE PROVIDED WITH A LAVATORY
THAT IS LOCATED SO THAT THE DISTANCE BETWEEN THE CENTRELINEOF THE LAVATORY AND THE SIDE WALL IS NOT LESS THAN 460 mm.b) HAS A RIM HEIGHT NOT MORE THAN 865 mm ABOVE THE FLOOR,c) HAS A CLEARANCE BENEATH THE LAVATORY NOT LESS THANi) 760 mm WIDE,ii) 735 mm HIGH AT THE FRONT EDGE,iii) 685 mm HIGH AT A POINT 205 mm BACK FROM THE FRONT EDGE, ANDiv) 230 mm HIGH OVER THE DISTANCE FROM A POINT 280 mm TO APOINT 430 mm BACK FROM THE FRONT EDGE.
URINAL:1. IF URINALS ARE PROVIDED IN A BARRIER-FREE WASHROOM, AT LEAST
ONE URINAL SHALL BEa) WALL MOUNTED, WITH THE RIM LOCATED BETWEEN 488 mm AND 512mm ABOVE THE FLOOR, ORb) FLOOR MOUNTED, WITH THE RIM LEVEL WITH THE FINISHED FLOOR.
2. THE URINAL DESCRIBED IN SENTENCE (1) SHALL HAVEa) A CLEAR WIDTH OF APPROACH OF 800 mm CENTRED ON THE URINAL.b) INSTALLED ON EACH SIDE A VERTICALLY MOUNTED GRAB BAR THATIS NOT LESS THAN 300 mm LONG, WITH ITS CENTERLINE 1 000 mmABOVE THE FLOOR, AND LOCATED NOT MORE THAN 380 mm FROM THECENTERLINE OF THE URINAL
1. AT LEAST ONE WATER CLOSET STALL OR ENCLOSURE IN A WASHROOMREQUIRED BY ARTICLE 3.8.2.3. TO BE BARRIER-FREE SHALL,a) BE NOT LESS THAN 1 500 mm WIDE BY 1 500 mm DEEP,b) BE EQUIPPED WITH A DOOR THAT(i) CAN BE LATCHED FROM THE INSIDE WITH A CLOSET FIST,(ii) PROVIDES A CLEAR OPENING NOT LESS THAN 800 mm WIDE WHEN ITIS OPEN,(iii) SWINGS OUTWARD, UNLESS SUFFICIENT ROOM IS PROVIDEDWITHIN THE STALL OR ENCLOSURE TO PERMIT THE DOOR TO BECLOSED WITHOUT INTERFERING WITH THE WHEELCHAIR, (SEEAPPENDIX A)(iv) IS PROVIDED ON THE INSIDE WITH A DOOR PULL NOT LESS THAN140 mm LONG LOCATED SO THAT ITS MIDPOINT IS NOT LESS THAN 200mm AND NOT MORE THAN 300 mm FROM THE HINGED SIDE OF THEDOOR AND NOT LESS THAN 900 mm AND NOT MORE THAN 1000 mmABOVE THE FLOOR (SEE APPENDIX A(v) IS PROVIDED WITH A DOOR PULL ON THE OUTSIDE, NEAR THELATCH SIDE OF THE DOOR,c) HAVE A WATER CLOSET LOCATED SO THAT THE CLEARANCEBETWEEN THE FIXTURE AND THE WALL ON ONE SIDE IS NOT LESSTHAN 285 mm AND NOT MORE THAN 305 mm,d) BE EQUIPPED WITH GRAB BARS THAT(i) ARE MOUNTED HORIZONTALLY ON THE SIDE WALL CLOSEST TO THEWATER CLOSET AND SHALL EXTEND NOT LESS THAN 450 mm IN BOTHDIRECTIONS FROM THE MOST FORWARD POINT OF THE WATERCLOSET (SEE APPENDIX A)(ii) IF THE WATER CLOSET DOES NOT HAVE AN ATTACHED WATERTANK, ARE AT LEAST 600 mm IN LENGTH, MOUNTED HORIZONTALLY ONTHE WALL BEHIND THE WATER CLOSET AND CENTERED ON THE TOILETBOWL,(iii) ARE MOUNTED NOT LESS THAN 840 mm AND NOT MORE THAN 920mm ABOVE THE FLOOR,(iv) ARE INSTALLED TO RESIST A LOAD OF NOT LESS THAN 1.3 kNAPPLIED VERTICALLY OR HORIZONTALLY,(v) ARE NOT LESS THAN 30 mm AND NOT MORE THAN 40 mm INDIAMETER, AND(vi) HAVE A CLEARANCE OF NOT LESS THAN 35 mm AND NOT MORETHAN 45 mm FROM THE WALL,e) BE EQUIPPED WITH A COAT HOOK MOUNTED NOT MORE THAN 1 200mm ABOVE THE FLOOR ON A SIDE WALL AND PROJECTING NOT MORETHAN 50 mm FROM THE WALL,f) HAVE A CLEARANCE OF AT LEAST 1 700 mm BETWEEN THE OUTSIDEOF THE STALL FACE AND THE FACE OF AN IN-SWINGING WASHROOMDOOR AND 1 400 mm BETWEEN THE OUTSIDE OF THE STALL FACE ANDANY WALL-MOUNTED FIXTURE.g) A WATER CLOSET FOR EACH PERSON WITH PHYSICAL DISABILITIESSHALL BE EQUIPPED WITH A SEAT LOCATED AT NOT LESS THAN 400 mmAND NOT MORE THAN 460 mm ABOVE THE FLOOR.
DATE REVISION1 09/19/2016 ISSUE FOR PERMIT2 10/28/2016 ISSUE FOR CONST.
Architectural Consultant:Powers Brown Architecture1 Church Hill Suite FSt. John's, NL A1C 3Z7709.726.3941713.224.0457 faxwww.powersbrown.com
SHEET NUMBER
A
B
C
D
1 2 3 4
GENERAL NOTES
PROJECT TITLE
SHEET TITLE
SEAL
1 2 3 4
A
B
C
D
124 GLENCOE DRIVEMOUNT PEARL, NL A1N 4S6
C:\U
sers
\ qua
n\D
ocum
ents
\163
016
CO
HE N
BTS
_Qua
n.rv
t10
/28/
2016
08:
58:2
0 AM
163016
DK
DR
COHEN'S HOMEFURNISHING
COHEN'S BTS
A101
OVERALL FIRST FLOORPLAN
SCALE: 3/32" = 1'-0"
OVERALL FIRST FLOOR PLAN
N
1 DESIGN BUILDER TO VERIFY SIZE OF FIRE ROOM,ELECTRICAL ROOM, SERVER ROOM, MECHANICALROOMS WITH OWNER AND DESIGN BUILDCONSULTANTS PRIOR TO CONSTRUCTION.
DATE REVISION1 09/19/2016 ISSUE FOR PERMIT2 10/28/2016 ISSUE FOR CONST.
NOTE: PROVIDE HIGH BAY LIGHTING INWAREHOUSE AREA. LIGHTING TOACHIEVE AVERAGE OF 35 F.C. - DESIGNBUILD ELEC. SUB CONTRACTOR TOVERIFY REQUIREMENT AND LAYOUT W/OWNER
CLR5' - 0"
CLR4' - 0"
CLR
5' - 0
"
CLR5' - 0"
12' - 0"8' - 0"10' - 0"
2' - 0"2' - 0"2' - 0"
2' - 0"2' - 0"2' - 0"2' - 0"
6' - 0"
4' - 0
"68
' - 0"
16' -
0"10
' - 0"
2' - 0
"EFFF F
B
A
NOTE: ROOM W/C 217IS A BARRIER-FREEWASHROOM PROVIDEDIN OFFICE AREA
A401A3
222
DENOTES FLOORING
DENOTES MILLWORK
FINISH LEGEND:
FINISH TRANSITION
A. ALL FLOORS TO BE TYPE - TYP UNO
B. ALL BASES TO BE TYPE - TYP UNOC. ALL WALLS TO BE TYPE - TYP UNOD. REFER TO SHEETS A501-A511 FOR ADDITIONAL
INFORMATION.
E. REFER TO SHEET A605 FOR FINISH SCHEDULE
F7
GENERAL NOTES:
B1
W1
F. REFER TO THE ENLARGED PLANS FOR ADDITIONALTAGS, NOTES, AND DIMENSIONS
Architectural Consultant:Powers Brown Architecture1 Church Hill Suite FSt. John's, NL A1C 3Z7709.726.3941713.224.0457 faxwww.powersbrown.com
SHEET NUMBER
A
B
C
D
1 2 3 4
GENERAL NOTES
PROJECT TITLE
SHEET TITLE
SEAL
1 2 3 4
A
B
C
D
124 GLENCOE DRIVEMOUNT PEARL, NL A1N 4S6
C:\U
sers
\ qua
n\D
ocum
ents
\163
016
CO
HE N
BTS
_Qua
n.rv
t10
/28/
2016
08:
58:2
3 AM
163016
DK
DR
COHEN'S HOMEFURNISHING
COHEN'S BTS
A102
OVERALL SECONDFLOOR PLAN
SCALE: 3/32" = 1'-0"
OVERALL SECOND FLOOR PLAN
N
1 DESIGN BUILDER TO VERIFY SIZE OF FIRE ROOM,ELECTRICAL ROOM, SERVER ROOM, MECHANICALROOMS WITH OWNER AND DESIGN BUILDCONSULTANTS PRIOR TO CONCTRUCTION.
DATE REVISION1 09/19/2016 ISSUE FOR PERMIT2 10/28/2016 ISSUE FOR CONST.
FEC = SEMI-RECESSED FIRE EXTINGUISHER CABINETFE = SURFACE MOUNTED FIRE EXTINGUISHER
A. ALL INTERIOR PARTITIONS TO GO TO DECK (TYP UNO)NOTES:
LEGEND:
INDICATES MILLWORK
B. FURNITURE & EQUIPMENT SHOWN FOR GRAPHICPURPOSES ONLY - N.I.C.
C. REFER TO FINISH PLANS FOR ADDITIONALINFORMATION.
D. REFER TO A601 FOR PARTITION TYPES.E. ALL VERTICAL FLOOR PENETRATIONS BETWEEN
FLOORS WITHIN LEVEL 01 AND LEVEL 02 OFFICE SPACETO BE PROTECTED BY A 1HR RATED WALL ASSEMBLY.
F. ALL INTERIOR FRAMED WALLS WITH GYP BOARD FINISHEXTENDING TO DECK ARE TO HAVE CONTROL JOINTSSPACED AT MAX 30 FT. O.C. (TYP).
G. ALL INTERIOR CONDITIONED SPACES TO BE PROVIDEDWITH MIN. 22 ROOF INSULATION AND WALLS TO BE ANINSULATION VALUE OF R13.
INDICATES BELOW LEVEL
H. ALL FIRE SPRINKLER HEADS WITHIN LOBBIES, OFFICES,AND CORRIDORS TO HAVE FULLY CONCEALEDSPRINKLER HEADS WITHIN SCHEDULED CEILINGMATERIAL & CENTERED WITHIN CEILING TILE WHEREAPPLICABLE.
J. ALL SLAB PENETRATIONS / SHAFTS TO BE PROTECTEDWITH IN A 1 HOUR RATED WALL ENCLOSURES.
DATE REVISION1 09/19/2016 ISSUE FOR PERMIT2 10/28/2016 ISSUE FOR CONST.
10/28/2016
11
B
A
A2A431
1 1/2" DIA STEELHANDRAIL -PAINTED (TYP)
1 1/2" DIA STEELGUARDRAIL -PAINTED (TYP)
9' - 3 1/4"6 5/8"
(CLR
.)7'
- 9"
10 T R
EADS
@ 11
" EA.
9' - 2
"(C
LR.)
4' - 2
"3'
- 0 3/
8"10
5/8"
(CLR.)4' - 2"5 1/4"
(CLR.)4' - 2"
N111
112STAIR 02
A6D
A6D
A6D
A6A
UP
A431D3
C3A431
11
B
A
A2A431
7 1/4"
(LAN D
ING)
7' - 5
7/8"
13 T R
EADS
@ 11
" EA.
11' -
11"
(LAN D
ING)
4' - 8
7/8"
3 1/8"
(CLR.)4' - 0"6 3/4"
9' - 2"7 1/4"
1 1/2" DIA STEELHANDRAIL -PAINTED (TYP)
1 1/2" DIA STEELGUARDRAIL -PAINTED (TYP)5'
- 0"
CLR .
FLOO
R OP
ENIN
G11
' - 11
"8'
- 1"
210STAIR 02
209
LUNCH /SOCIAL
210
(CLR. FLOOR OPENING)4' - 7 1/4"
A6D
A6A
A3A
A3A
A3A
DN
C2A431
(CLR.)4' - 2"5 1/4"
LEVEL 010"
LEVEL 0213' - 0"
BA
EAVE HEIGHT28' - 1"
T.O. PARAPET 128' - 1"
13 TR
EADS
@ 11
" EA.
7' - 3
3/8"
10 TR
EADS
@ 11
" EA.
5' - 8
5/8"
1 1/2" DIA STEELHANDRAIL -PAINTED (TYP)
1 1/2" DIA STEELGUARDRAIL -PAINTED (TYP)
UNDERSLABWEATHERBARRIER
CONCRETESLAB
SPECIFIEDROOFING
(CLR
.)6'
- 11 3
/8"
2' - 1
0"2'
- 10"
3' - 6
"
210STAIR 02
112STAIR 02
A431B1
A431C1
A431D1
DOCK LEVEL-4' - 0"
PICKUP LEVEL-2' - 4"
LOW EAVE HT.26' - 0"
1"1 1/2" DIA STEEL HANDRAIL -TERMINATE @ GUARDRAIL -PAINTED (TYP)
1 1/2" DIA STEELGUARDRAIL - PAINTED (TYP)
3/4" DIA STEELPICKET -PAINTED (TYP)
MIN
3' - 6
"2'
- 10"
MIN
TO 3'
- 0" M
AX
1 1/2" DIA STEELPIPE RAIL -PAINTED (TYP)
MAX4"
MAX4"
1'-0" AT TOP OF STAIR
1'-11" AT BOTTOM OF STAIR
SCHEDULEDPARTITION
1 1/2" DIA STEEL HANDRAIL- PAINTEDLINE OF STAIR NOSINGBELOW
1 1/2"
1 1/2"
STEEL STRINGER -PAINTED - TYP
STAIR TREADBEYOND
CONCRETELANDING
1 1/2" DIA GUARDRAILPOST - PAINTED (TYP)
3/4" DIA VERTICALSTEEL PICKET - 4" O.C.MAX - PAINTED (TYP)
4"
STEEL CHANNEL SUPPORT -PAINTED (TYP)
CONCRETELANDING
1 1/2" DIAGUARDRAIL POST -PAINTED (TYP)
3/4" DIAVERTICALSTEEL PICKET- 4" O.C. MAX -PAINTED (TYP)
1 1/2" DIASTEEL PIPERAIL -PAINTED(TYP)
4"
STEEL STRINGER -PAINTED (TYP)
CONCRETELANDING
1 1/2" DIAGUARDRAILPOST - PAINTED(TYP) 3/4" DIA VERTICAL STEEL
PICKET - 4" O.C. MAX -PAINTED (TYP)
1 1/2" DIA STEELPIPE RAIL -PAINTED(TYP)
4"STEEL STRINGER -PAINTED (TYP)
RETURN HANDRAILTO WITHIN 1/4" OFWALL
1 1/2" DIA STEEL PIPEHANDRAIL - PAINTED (TYP)
FIRE TREATEDWOOD BLOCKING
STEEL WALLBRACKET - PAINTED(TYP)
SCHEDULEDPARTITION
1 1/2" 1 1/2"
MAX4"
MIN
3' - 6
"
2' - 1
0" MI
N TO
3 '- 0
" MAX
1 1/2" DIA STEELGUARDRAIL - PAINTED(TYP)
1 1/2" DIA STEELHANDRAIL -PAINTED (TYP)
3/4" DIA STEELPICKET -PAINTED (TYP)
1 1/2" DIA STEELPIPERAIL -PAINTED (TYP)
1 1/2"
FEC = SEMI-RECESSED FIRE EXTINGUISHER CABINETFE = SURFACE MOUNTED FIRE EXTINGUISHER
A. ALL INTERIOR PARTITIONS TO GO TO DECK (TYP UNO)NOTES:
LEGEND:
INDICATES MILLWORK
B. FURNITURE & EQUIPMENT SHOWN FOR GRAPHICPURPOSES ONLY - N.I.C.
C. REFER TO FINISH PLANS FOR ADDITIONALINFORMATION.
D. REFER TO A601 FOR PARTITION TYPES.E. ALL VERTICAL FLOOR PENETRATIONS BETWEEN
FLOORS WITHIN LEVEL 01 AND LEVEL 02 OFFICE SPACETO BE PROTECTED BY A 1HR RATED WALL ASSEMBLY.
F. ALL INTERIOR FRAMED WALLS WITH GYP BOARD FINISHEXTENDING TO DECK ARE TO HAVE CONTROL JOINTSSPACED AT MAX 30 FT. O.C. (TYP).
G. ALL INTERIOR CONDITIONED SPACES TO BE PROVIDEDWITH MIN. 22 ROOF INSULATION AND WALLS TO BE ANINSULATION VALUE OF R13.
INDICATES BELOW LEVEL
H. ALL FIRE SPRINKLER HEADS WITHIN LOBBIES, OFFICES,AND CORRIDORS TO HAVE FULLY CONCEALEDSPRINKLER HEADS WITHIN SCHEDULED CEILINGMATERIAL & CENTERED WITHIN CEILING TILE WHEREAPPLICABLE.
J. ALL SLAB PENETRATIONS / SHAFTS TO BE PROTECTEDWITH IN A 1 HOUR RATED WALL ENCLOSURES.
E3F 3 5/8" SEE PLAN 16" O.C. 3 5/8" 06 09 N/AE6A 6" 16" O.C. N/A
SCALE: 1 1/2" = 1'-0"
PARTITION TYPE 'K'
SCALE: 1 1/2" = 1'-0"BASE DETAIL09
SCALE: 1 1/2" = 1'-0"BASE DETAIL10
SCALE: 1 1/2" = 1'-0"HEAD DETAIL (D)04
SCALE: 1 1/2" = 1'-0"HEAD DETAIL (E)05
SCALE: 1 1/2" = 1'-0"HEAD DETAIL (C)03
SCALE: 1 1/2" = 1'-0"HEAD DETAIL (A)01
SCALE: 1 1/2" = 1'-0"HEAD DETAIL (F)06
SCALE: 1 1/2" = 1'-0"HEAD DETAIL (B)02
A NOT ALL PARTITION TYPES SHOWN MAY BE USED;REFER TO PLANS FOR LOCATIONS AND EXTENT
B PROVIDE CEMENTITOUS WALL BOARD IN LIEU OF 5/8"GYP BOARD AT ALL WALLS TO RECEIVE PORCELAINTILE, STONE, CERAMIIC TILE OR FRP
C WHERE U.L. ASSEMBLIES OR OTHER TESTEDASSEMBLIES ARE INDICATED, COMPLY WITH DETAILEDREQUIREMENTS SHOWN ON U.L. ASSEMBLY SHEETS.U.L. ASSEMBLIES (OR OTHER TESTED ASSEMBLIES)REQUIREMENTS OVERRIDE THE PBA PARTITIONS
D REFER TO FINISH SCHEDULE AND/OR FINISH PLAN FORLOCATIONS OF SPECIAL FIRE-RESISTIVE WALLBOARD,FOIL-BACKED GYPSUM WALLBOARD,ABUSIVE-RESISTANT GYPSUM WALLBOARD,WATER-RESISTANT GYPSUM WALLBOARD, GLASS-MATWATER-RESISTANT BACKING BOARD, ORCEMENTITIOUS BACKER UNITS THAT MAY BE REQUIREDIN PLACE OF GYPSUM WALLBOARD INDICATED
E INSTALL CONTROL JOINTS AT LOCATIONS INDICATED. IFNOT INDICATED, DETERMINE LOCATIONS BYCONSULTING WITH ARCHITECT
F BATT INSULATION TO BE INSTALLED B/W STUD FRAMINGINSIDE EXTERIOR WALL FURRING AND BETWEEN ALLROOF FRAMING MEMEBERS. SECURE ROOFINSULATION BATTS IN PLACE WITH WIRE MESHATTACHED TO FRAMING MEMEBERS
G INTERIOR ROOF BATT INSULATION TO MEET MINIMUMJURISDICTION PERFORMANCE REQUIREMENTS
H INSULATION ALONG EXTERIOR WALL FURRING ANDROOF SPACES TO BE INSTALLED WITHOUT GAPS ORVOIDS; DO NOT COMPRESS INSULATION. USE R-19 ONROOFS AND R-13 ON WALL, UNO
J MAXIMUM CLEAR SPAN HEIGHTS FOR INTERIOR METALSTUDS SHALL BE SUCH THAT DEFLECTION SHALL NOTEXCEED L/360 UNDER A 5 PSF LOAD (CERAMIC TILEFINISHES) AND L/240 AT ALL OTHER AREAS
SCALE: 1 1/2" = 1'-0"HEAD DETAIL (G)07
SCALE: 1 1/2" = 1'-0"HEAD DETAIL (H)08
DATE REVISION1 09/19/2016 ISSUE FOR PERMIT2 10/28/2016 ISSUE FOR CONST.
Architectural Consultant:Powers Brown Architecture1 Church Hill Suite FSt. John's, NL A1C 3Z7709.726.3941713.224.0457 faxwww.powersbrown.com
SHEET NUMBER
A
B
C
D
1 2 3 4
GENERAL NOTES
PROJECT TITLE
SHEET TITLE
SEAL
1 2 3 4
A
B
C
D
124 GLENCOE DRIVEMOUNT PEARL, NL A1N 4S6
C:\U
sers
\ qua
n\D
ocum
ents
\163
016
CO
HE N
BTS
_Qua
n.rv
t10
/28/
2016
09:
00:0
5 AM
163016
DK
DR
COHEN'S HOMEFURNISHING
COHEN'S BTS
A602
DOOR AND FRAMESCHEDULE
DOOR ASSEMBLY DOOR MATERIAL FRAME MATERIAL
Hard
ware
Set
Fire R
ating
RemarksNumber Type Description
Dimensions
Door Material Finish Material FinishWidt
h
Heigh
t
Thick
ness
101 A SINGLE 3' - 0" 7' - 0" 1 3/4" HM PAINTED HM CLRANODIZED
101-EXT D SINGLE 3' - 0" 7' - 8" 1" ALUM W/GLAZING
VISION ALUM CLRANODIZED
105 A SINGLE 3' - 0" 7' - 0" 1 3/4" HM PAINTED HM PAINTED105A A SINGLE 3' - 0" 7' - 0" 1 3/4" HM PAINTED HM PAINTED106 A SINGLE 3' - 0" 7' - 0" 1 3/4" HM PAINTED HM PAINTED107 A SINGLE 3' - 0" 7' - 0" 1 3/4" HM PAINTED HM PAINTED108 A SINGLE 3' - 0" 7' - 0" 1 3/4" HM PAINTED HM PAINTED109 A SINGLE 3' - 0" 7' - 0" 1 3/4" HM PAINTED HM PAINTEDN101 E OVERHEAD 8' - 0" 9' - 0" 2" STEEL PREFINISHED STEEL PREFINISHED SECTIONAL OH DOORN102 E OVERHEAD 8' - 0" 9' - 0" 2" STEEL PREFINISHED STEEL PREFINISHED SECTIONAL OH DOORN103 A SINGLE 3' - 0" 7' - 0" 1 3/4" HM PAINTED HM PAINTEDN104 E OVERHEAD 8' - 0" 9' - 0" 2" STEEL PREFINISHED STEEL PREFINISHED SECTIONAL OH DOORN105 E OVERHEAD 8' - 0" 9' - 0" 2" STEEL PREFINISHED STEEL PREFINISHED SECTIONAL OH DOORN106 E OVERHEAD 8' - 0" 9' - 0" 2" STEEL PREFINISHED STEEL PREFINISHED SECTIONAL OH DOORN107 E OVERHEAD 8' - 0" 9' - 0" 2" STEEL PREFINISHED STEEL PREFINISHED SECTIONAL OH DOORN108 E OVERHEAD 12' - 0" 12' - 0" 2" STEEL PREFINISHED STEEL PREFINISHED SECTIONAL OH DOORN109 A SINGLE 3' - 0" 7' - 0" 1 3/4" HM PAINTED HM PAINTEDN110 A SINGLE 3' - 0" 7' - 0" 1 3/4" HM PAINTED HM PAINTEDN111 A SINGLE 3' - 0" 7' - 0" 1 3/4" HM PAINTED HM PAINTEDS101 A SINGLE 3' - 0" 7' - 0" 1 3/4" HM PAINTED HM PAINTEDS102 A SINGLE 3' - 0" 7' - 0" 1 3/4" HM PAINTED HM PAINTEDS103 A SINGLE 3' - 0" 7' - 0" 1 3/4" HM PAINTED HM PAINTED203 C SINGLE 3' - 0" 7' - 8" 1 3/4" ALUM W/
GLAZINGVISION ALUM CLR
ANODIZED204 C SINGLE 3' - 0" 7' - 8" 1 3/4" ALUM W/
GLAZINGVISION ALUM CLR
ANODIZED205 C SINGLE 3' - 0" 7' - 8" 1 3/4" ALUM W/
GLAZINGVISION ALUM CLR
ANODIZED206 C SINGLE 3' - 0" 7' - 8" 1 3/4" ALUM W/
GLAZINGVISION ALUM CLR
ANODIZED207 C SINGLE 3' - 1" 7' - 8" 1 3/4" ALUM W/
GLAZINGVISION ALUM CLR
ANODIZED208 A SINGLE 3' - 0" 7' - 0" 1 3/4" HM PAINTED HM PAINTED208A A SINGLE 3' - 0" 7' - 0" 1 3/4" HM PAINTED HM PAINTED209 C SINGLE 3' - 0" 7' - 8" 1 3/4" ALUM W/
GLAZINGVISION ALUM CLR
ANODIZED210 A SINGLE 3' - 0" 7' - 0" 1 3/4" HM PAINTED HM PAINTED211 A SINGLE 3' - 0" 7' - 0" 1 3/4" HM PAINTED HM PAINTED212 C SINGLE 2' - 9" 7' - 8" 1 3/4" ALUM W/
GLAZINGVISION ALUM CLR
ANODIZED212A A SINGLE 3' - 0" 7' - 0" 1 3/4" HM PAINTED HM PAINTED213 C SINGLE 2' - 9" 7' - 8" 1 3/4" ALUM W/
GLAZINGVISION ALUM CLR
ANODIZED214 A SINGLE 3' - 0" 7' - 0" 1 3/4" HM PAINTED HM PAINTED215 A SINGLE 3' - 0" 7' - 0" 1 3/4" HM PAINTED HM PAINTED216 A SINGLE 3' - 0" 7' - 0" 1 3/4" HM PAINTED HM PAINTED217 A SINGLE 3' - 0" 7' - 0" 1 3/4" HM PAINTED HM PAINTED218 A SINGLE 3' - 0" 7' - 0" 1 3/4" HM PAINTED HM PAINTED219 A SINGLE 3' - 0" 7' - 0" 1 3/4" HM PAINTED HM PAINTED220 A SINGLE 3' - 0" 7' - 0" 1 3/4" HM PAINTED HM PAINTED221 A SINGLE 3' - 0" 7' - 0" 1 3/4" HM PAINTED HM PAINTED222 A DOUBLE 4' - 0" 7' - 0" 1 3/4" HM PAINTED HM PAINTED224 A SINGLE 3' - 0" 7' - 0" 1 3/4" HM PAINTED HM PAINTED
DOOR & FRAME SCHEDULE
DOOR ELEVATIONS
DOOR HARDWARE SCHEDULEHW SET: 02SINGLE - STOREFRONT ENTRANCE - EXTERIOR
1 EA PIVOT SET 195 3/4" Offset 626 Rixson2 EA INTERMEDIATE PIVOT M19 3/4" Offset 626 Rixson1 EA RIM EXIT DEVICE - NL ED4200 x K157 630 Corbin Russwin1 EA RIM CYLINDER 3000-058 626 Corbin Russwin1 EA OFFSET DOOR PULL BF257 630 Rockwood1 EA SURFACE CLOSER w/ STOP CLP7500 689 Norton1 EA DROP PLATES & MTG BRKTS 7788 x 6890 x 6891 689 Rixson1 SET PERIMETER SEALS BY DOOR MANUFACTURER B/O1 EA DOOR SWEEP w/ DRIP EDGE 345ANB Pemko1 EA LIP THRESHOLD 2005AT PemkoSpecial Note: Add the following items below if opening requires Card Access Readers by others.1 EA ELECTRIC STRIKE 9600 630 HES1 EA POWER CONTROLLER 2005M3 HES1 EA POWER SUPPLY AQD3 Securitron1 EA
CARD READER BY OTHERS1 EA CONTROLLER/WIRING BY OTHERS1 EA REX BY OTHERS
HW SET: 05SINGLE - HOLLOW METAL EGRESS/ACCESS DOOR (WAREHOUSE) - EXTERIOR
4 EA HINGE T4A3386 4.5 X 4.5 NRP 630 McKinney1 EA EXIT DEVICE - NL ED5200 x P957 630 Corbin Russwin1 EA RIM CYLINDER 3000-200 626 Corbin Russwin1 EA SURFACE CLOSER w/ STOP CLP8501 689 Norton1 EA KICK PLATE K1050 10" x 2"LDW 630 Rockwood1 SET PERIMETER SEALS 2891APK Pemko1 EA DOOR SWEEP w/ DRIP EDGE 345ANB Pemko1 EA RAIN DRIP 346C Pemko1 EA LIP THRESHOLD 2005AT PemkoNote: Install perimeter seal prior to templating and installing door closer and stop.Special Note: Add the following items below if opening requires Card Access Readers by others.1 EA ELECTRIC STRIKE 9600 630 HES1 EA POWER CONTROLLER 2005M3 HES1 EA POWER SUPPLY AQD3 Securitron1 EA CARD READER BY OTHERS1 EA CONTROLLER/WIRING BY OTHERS1 EA REX BY OTHERS
HW SET: 06SINGLE - HOLLOW METAL EGRESS ONLY DOOR (WAREHOUSE/STAIR) - EXTERIOR
4 EA HINGE T4A3386 4.5 X 4.5 NRP 630 McKinney1 EA EXIT DEVICE - EXIT ONLY ED5200 EO 630 Corbin Russwin1 EA SURFACE CLOSER w/ STOP CLP8501 689 Norton1 EA KICK PLATE K1050 10" x 2"LDW 630 Rockwood1 SET PERIMETER SEALS 2891APK Pemko1 EA DOOR SWEEP w/ DRIP EDGE 345ANB Pemko1 EA RAIN DRIP 346C Pemko1 EA LIP THRESHOLD 2005AT Pemko
4 EA HINGE TA2714 4.5 X 4.5652 McKinney1 EA ENTRANCE/OFFICE LOCK CL3851 AZD 626 Corbin Russwin1 EA DOOR STOP 442/409 626 Rockwood3 EA SILENCER By Door Frame Supplier
4 EA HINGE TA2714 4.5 X 4.5 652 McKinney1 EA STOREROOM LOCK CL3857 AZD 626 Corbin Russwin1 EA DOOR STOP 442/409 626 Rockwood3 EA SILENCER By Door Frame Supplier
HW SET: 11SINGLE - TOILET ROOM - INTERIOR
4 EA HINGE TA2714 4.5 X 4.5 652 McKinney1 EA PRIVACY SET CL3820 AZD 626 Corbin Russwin1 EA SURFACE CLOSER 8501 (Mnt Closer on Room Side) 689 Norton1 EA MOP PLATE K1050 6" x 2"LDW 630 Rockwood1 EA DOOR STOP 442/409 626 Rockwood3 EA SILENCER By Door Frame Supplier
HW SET: 15OVERHEAD ROLL-UP DOOR - EXTERIOR
1 EA PADLOCK PL5000 AS REQ'D Corbin RusswinNOTE: BALANCE OF HARDWARE BY DOOR MANUFACTURER B/O
HW SET: 23SINGLE - MECHANICAL TYPE ROOMS - EXTERIOR
4 EA HINGE TA2314 4.5 X 4.5 NRP 630 McKinney1 EA STOREROOM LOCK CL3357 AZD 626 Corbin Russwin1 EA CLOSER w/ STOP CLP8501 689 Norton1 SET PERIMETER SEALS 2891APK Pemko1 EA DOOR SWEEP w/ DRIP EDGE 345ANB Pemko1 EA RAIN DRIP 346C Pemko1 EA LIP THRESHOLD 2005AT PemkoNote: Install perimeter seal prior to templating and installing door closer and stop.
HW SET: 25 SINGLE - RATED - STAIRWELL EGRESS- INTERIOR
4 EA HINGE T4A3386 4.5 X 4.5 NRP 630 McKinney1 EA EXIT DEVICE w/ LEVER ED5200A A910 689 Corbin Russwin1 EA SURFACE CLOSER 8501 (Mnt Closer on Room Side) 689 Norton1 EA KICK PLATE K1050 10" x 2"LDW 630 Rockwood1 EA DOOR STOP 442/409 626 Rockwood1 SET PERIMETER SEALS S773 BL Pemko
HW SET: 08PAIR - NON-RATED -STORAGE - INTERIOR
8 EA HINGE TA2714 4.5 X 4.5 652 McKinney2 EA MANUAL FLUSH BOLT 555 626 Rockwood1 EA DUST PROOF STRIKE 570 626 Rockwood1 EA STOREROOM LOCK ML2057 110X 626 Corbin Russwin2 EA OH STOP 9-SERIES 630 Rixson2 EA SILENCER By Door Frame Supplier
HW SET: 18SINGLE- FULL GLASS CONF - INTERIOR
1 EA CONCEALED CLOSER BY DOOR MFGR. B/O2 EA STRAIGHT PULLS RM3300 - 84" 630 Rockwood1 EA DOOR STOP 446 626 Rockwood
DATE REVISION1 09/19/2016 ISSUE FOR PERMIT2 10/28/2016 ISSUE FOR CONST.