Page 1: Code Update: International Building Code NFPA 5000 William E. Koffel, P.E. Koffel Associates, Inc.

Code Update:International Building Code

NFPA 5000

William E. Koffel, P.E.

Koffel Associates, Inc.

Page 2: Code Update: International Building Code NFPA 5000 William E. Koffel, P.E. Koffel Associates, Inc.

Overview

• Changes in the model code organizations

• Overview of issues in NFPA 5000

• Overview of recent code change proposals to the International Building Code

• Discuss the curtain wall/spandrel wall issues

Page 3: Code Update: International Building Code NFPA 5000 William E. Koffel, P.E. Koffel Associates, Inc.

Regional US Building Codes

• BOCA National Building Code

• Uniform Building Code

• Standard Building Code

Page 4: Code Update: International Building Code NFPA 5000 William E. Koffel, P.E. Koffel Associates, Inc.

ICBOUniform Bldg. Code

SBCCIStandard Bldg. Code

BOCANational Bldg. Code

Page 5: Code Update: International Building Code NFPA 5000 William E. Koffel, P.E. Koffel Associates, Inc.

= Region Dominated by SBCCI

= Region Dominated by BOCA

= Region Dominated by ICBO = Region Shared by ICBO & SBCCI

SBCCIICBO

BOCA

= States Having Local Codes Significantly Different from Model Codes

Dominant Model Code in Local Building Regulations

Page 6: Code Update: International Building Code NFPA 5000 William E. Koffel, P.E. Koffel Associates, Inc.

NationalBldg. Code (99)

StandardBldg. Code (99)

UniformBldg. Code (97)

SBCCI ICBOBOCA

InternationalBldg. Code (2000)

International Code Council

Page 7: Code Update: International Building Code NFPA 5000 William E. Koffel, P.E. Koffel Associates, Inc.

= Region Dominated by SBCCI

= Region Dominated by BOCA

= Region Dominated by ICBO = Region Shared by ICBO & SBCCI

= States Having Local Codes Significantly Different from Model Codes

= States Considering IBC = Possible NFPA States

Dominant Code in Local Building Regulations

Page 8: Code Update: International Building Code NFPA 5000 William E. Koffel, P.E. Koffel Associates, Inc.

Current Vision of NFPA Consensus Codes™ Set

• Referred to as C3 Codes• Fire—NFPA 1, Uniform Fire Code—Harmonized

with UFC in 2003• Electrical—NFPA 70, National Electrical Code®• Plumbing—Uniform Plumbing Code—processed

through NFPA procedures in 2003• Mechanical—Uniform Mechanical Code—

processed through NFPA procedures in 2003

Page 9: Code Update: International Building Code NFPA 5000 William E. Koffel, P.E. Koffel Associates, Inc.

Current Vision of NFPA Consensus Codes™ Set

• Fuel Gas—NFPA 54, National Fuel Gas Code—AGA partnership continues

• Building—NFPA Building Code ™ Based on EPCOT Building Code (RCID), NFPA Life Safety Code® and other NFPA Codes and Standards; Standards and Design Information from ASCE, ASTM, UL, FEMA, NCSEA and Others.

Page 10: Code Update: International Building Code NFPA 5000 William E. Koffel, P.E. Koffel Associates, Inc.

Current Vision of NFPA Consensus Codes™ Set

• Energy Efficiency—ASHRAE 90.1 and 90.2

• Manufactured Housing—NFPA 501; HUD Partnership

• Residential—Keep in NFPA 5000– Extract document in future

Page 11: Code Update: International Building Code NFPA 5000 William E. Koffel, P.E. Koffel Associates, Inc.

NFPA Building Code Committees

• Technical Correlating Committee

• 13 Committees with dual roles – LSC and Building Code

• 3 New Technical Committees:– Structures and Construction– Building Materials– Building Systems

Page 12: Code Update: International Building Code NFPA 5000 William E. Koffel, P.E. Koffel Associates, Inc.

Scope TC on Fire Protection Features

• Responsible for documents on construction compartmentation, including the performance of:– assemblies, – openings, and – penetrations

• as related to the protection of life and property from fire and other circumstances.

Page 13: Code Update: International Building Code NFPA 5000 William E. Koffel, P.E. Koffel Associates, Inc.

Model Codes Form the Basis for Local Regulations &

Local Building Codes Affect the Market For Building

Products

Page 14: Code Update: International Building Code NFPA 5000 William E. Koffel, P.E. Koffel Associates, Inc.

Critical Dates

• International Codes– 2003 Editions will be available in February

2003– Deadline for proposed changes – March 24,

2003– Two eighteen month cycles to development of

2006 Edition– Possibility of off-site voting

Page 15: Code Update: International Building Code NFPA 5000 William E. Koffel, P.E. Koffel Associates, Inc.

Critical Dates

• NFPA 5000/101– NFPA 5000-2002 Edition now available– NFPA 101 – 2003 Edition to be voted on my

NFPA membership in Nov. 20, 2002– Documents will be moved to the same cycle

• Deadline for changes not yet announced

• Probably early 2004

Page 16: Code Update: International Building Code NFPA 5000 William E. Koffel, P.E. Koffel Associates, Inc.

The Future is NOW!!!

Page 17: Code Update: International Building Code NFPA 5000 William E. Koffel, P.E. Koffel Associates, Inc.

Code Issues To Be Discussed

• Smoke leakage

• Quality assurance

• Perimeter fire barrier systems

Page 18: Code Update: International Building Code NFPA 5000 William E. Koffel, P.E. Koffel Associates, Inc.

Smoke Leakage

• Smoke Barriers – Subdivision of building space intended to provide a temporary area of refuge for building occupants

• Smoke Partition – Partition intended to provide a minimal amount of time for people to pass by an area

• Both use terms such as “limit”, “restrict”, or “resist” smoke leakage

Page 19: Code Update: International Building Code NFPA 5000 William E. Koffel, P.E. Koffel Associates, Inc.

IBC

• Smoke Barrier – Penetrations shall comply with Section 711 (general section on penetrations)

• Smoke Partition (new to 2002 Supplement) – Annular space shall be filled with an approved material to resist the passage of flame and products of combustion

Page 20: Code Update: International Building Code NFPA 5000 William E. Koffel, P.E. Koffel Associates, Inc.

IBC – 2002 Changes

• FS33-02 submitted by Hilti, Inc.– Required penetrations of smoke partitions to be

protected with materials or systems that can withstand 400oF and capable of withstanding anticipated movement of the penetrating item

– Disapproved

Page 21: Code Update: International Building Code NFPA 5000 William E. Koffel, P.E. Koffel Associates, Inc.

IBC – 2002 Changes

• FS38-02 submitted by 3M Company– Required penetrations of corridor walls and

smoke barriers to meet a leakage rate of 25 cfm per sq ft as determined by UL 1479.

– Disapproved– Public Comment submitted by the IFC but the

item was still disapproved.

Page 22: Code Update: International Building Code NFPA 5000 William E. Koffel, P.E. Koffel Associates, Inc.

NFPA 5000

• Where the penetrating item uses a sleeve to penetrate the smoke barrier, …the space between the item and the sleeve shall be be filled with a material capable of resisting the transfer of smoke, in accordance with the air leakage requirements of section 6 of UL 1479.

Page 23: Code Update: International Building Code NFPA 5000 William E. Koffel, P.E. Koffel Associates, Inc.

NFPA 5000

• All proposed changes attempting to introduce an air leakage requirement failed the written ballot of the Technical Committee

Page 24: Code Update: International Building Code NFPA 5000 William E. Koffel, P.E. Koffel Associates, Inc.

Quality Assurance

• How to ensure that the selection and installation of penetration firestopping has been properly executed.

Page 25: Code Update: International Building Code NFPA 5000 William E. Koffel, P.E. Koffel Associates, Inc.

IBC – 2002 Changes

• FS110-02 submitted by the FCIA– Installations shall be subjected to special

inspections conducted in accordance with ASTM E2174

• Exception: Where the code official performs the inspection

– Disapproved

Page 26: Code Update: International Building Code NFPA 5000 William E. Koffel, P.E. Koffel Associates, Inc.

NFPA 5000

• A quality assurance program shall be prepared and monitored by the registered design professional for firestop systems and devices and systems installed to protect joints.

• Text is in NFPA 5000

Page 27: Code Update: International Building Code NFPA 5000 William E. Koffel, P.E. Koffel Associates, Inc.

Any Questions?

Page 28: Code Update: International Building Code NFPA 5000 William E. Koffel, P.E. Koffel Associates, Inc.

IBC - 2000

• 712.2 Exterior curtain wall/floor construction– Where fire resistance-rated floor or

floor/ceiling assemblies are required, voids created at the intersection of the exterior curtain wall assemblies and such floor assemblies shall be sealed with an approved material.

Page 29: Code Update: International Building Code NFPA 5000 William E. Koffel, P.E. Koffel Associates, Inc.

IBC - 2000

• 712.2 Exterior curtain wall/floor construction– Such material shall be securely installed and capable of

preventing the passage of flame and hot gases sufficient to ignite cotton waste where subjected to ASTME E119 time-temperature fire conditions under a minimum positive pressure differential of 0.01 inch of water column for the time period at least equal to the fire-resistance rating of the floor assembly

Page 30: Code Update: International Building Code NFPA 5000 William E. Koffel, P.E. Koffel Associates, Inc.

2002 Changes to the IBC

• FS39-02 submitted by FCIA– Where fire resistance-rated floor or floor/ceiling

assemblies are required, voids created at the intersection of the exterior curtain wall assemblies and such floor assemblies shall be sealed with an approved system to prevent the interior spread of fire. Such system…..

– Approved as Modified

• Similar change submitted to NFPA 5000 was accepted by the Committee but failed ballot

Page 31: Code Update: International Building Code NFPA 5000 William E. Koffel, P.E. Koffel Associates, Inc.

2002 Changes to the IBC

• FS40-02 submitted by GICC– Add a new sentence to read as follows– Height and fire-resistance requirements for curtain wall

spandrels shall comply with Section 704.9.– Approved although Public Comment by Thermafiber

requested disapproval– Nothing in this change eliminates perimeter fire

barrier systems in sprinklered buildings!

• Similar change submitted to NFPA 5000 was accepted

Page 32: Code Update: International Building Code NFPA 5000 William E. Koffel, P.E. Koffel Associates, Inc.

2002 Changes to the IBC

• FS41-02 submitted by Metal Construction Association– ..for the time period equal to the fire-resistance rating

of the exterior curtain wall assembly, or 30 minutes, whichever is greater.

• Exception: Where the floor is less than the wall, the floor fire resistance shall be the criteria

– Disapproved

• Similar change submitted to NFPA 5000 was accepted by the Committee but failed ballot

Page 33: Code Update: International Building Code NFPA 5000 William E. Koffel, P.E. Koffel Associates, Inc.

NFPA 5000

• Where fire resistance-rated floor or floor-ceiling assemblies are required, voids created at the intersection of the exterior curtain wall assemblies and such floor assemblies shall be sealed with approved materials.

Page 34: Code Update: International Building Code NFPA 5000 William E. Koffel, P.E. Koffel Associates, Inc.

NFPA 5000

• Such materials shall be capable of preventing the passage of flame and hot gases sufficient to ignite cotton waste where subjected to NFPA 251 time-temperature fire conditions under a minimum positive pressure differential of .01 in. of water column for the time period at least equal to the fire resistance rating of the floor assembly.

Page 35: Code Update: International Building Code NFPA 5000 William E. Koffel, P.E. Koffel Associates, Inc.

NFPA 5000

• Annex note indicated that the intent is to prevent the interior spread of fire through the void space and not the exterior spread of fire.

Page 36: Code Update: International Building Code NFPA 5000 William E. Koffel, P.E. Koffel Associates, Inc.

Issues To Be Addressed

• Clarify that the reduction in the spandrel wall requirements for sprinklered buildings does NOT eliminate requirement for perimeter fire barrier systems– Propose language to 704 to require compliance

with 712 in a paragraph separate from the sprinkler exception for spandrel wall protection.

Page 37: Code Update: International Building Code NFPA 5000 William E. Koffel, P.E. Koffel Associates, Inc.

Issues To Be Addressed

• Spandrel wall requirements– Currently in exterior wall section– Listing of perimeter fire barrier system could

influence height of spandrel wall• Reason for GICC proposed language

– Are the existing requirements adequate?– Is this an issue for the FCIA?

Page 38: Code Update: International Building Code NFPA 5000 William E. Koffel, P.E. Koffel Associates, Inc.

Spandrel Wall Issues

• Increase in height– Opponents include BOMA, architects, curtain wall

industry, exterior wall panel and glazing industry

– Previous attempts in past 15 years have all failed

– Where is the loss experience, especially in sprinklered buildings?

• IBC requires sprinkler protection in buildings of 55 ft.

– What about other non-rated exterior wall systems?

Page 39: Code Update: International Building Code NFPA 5000 William E. Koffel, P.E. Koffel Associates, Inc.

Spandrel Wall Issues

• Risk to FCIA– If the perception is that the increased spandrel

wall is required due to perimeter fire barrier system, requirements could be changed to determine perimeter fire barrier performance based on exterior wall requirements

Page 40: Code Update: International Building Code NFPA 5000 William E. Koffel, P.E. Koffel Associates, Inc.

Questions???