Top Banner
FILTRATION DIESEL FUEL CONDITIONING REMOVE WATER & PARTICLES TO EXTEND FUEL INJECTOR LIFE & INCREASE COMBUSTION ENGINE FUEL EFFICIENCY COD Remove free water to saturation point with high single pass efficiency (achieve 50 ppm one pass #2 diesel) Rapid removal of free water in high concentrations. Ideal for mining & construction fueling depots and tank farms Available without pump & motor for installation into existing delivery system Condition fuel during bulk tank fill, service truck filling or as kidney loop to maintain clean & dry fuel Automatic water drain circuit for easy 24 / 7 unattended operation Auto-electrical phase reversal and smart relay control panel yields easy & reliable operation Before After www.hyprofiltration.com
8

COD DIESEL FUEL CONDITIONING - Vision SolutionsDiesel Fuel Cleanliness Requirements - What Has Changed? • Injector pressures have increased from 3,000 psi to over 30,000 psi (electronic).

May 31, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: COD DIESEL FUEL CONDITIONING - Vision SolutionsDiesel Fuel Cleanliness Requirements - What Has Changed? • Injector pressures have increased from 3,000 psi to over 30,000 psi (electronic).

FILTRATION

DIESEL FUELCONDITIONINGREMOVE WATER & PARTICLES TO EXTEND FUEL INJECTOR LIFE & INCREASE COMBUSTION ENGINE FUEL EFFICIENCY

COD

Remove free water to saturation •pointwithhighsinglepassefficiency(achieve50ppmonepass#2diesel)

Rapidremovaloffreewaterinhigh•concentrations.

Idealformining&constructionfueling•depotsandtankfarms

Availablewithoutpump&motorfor•installationintoexistingdeliverysystem

Conditionfuelduringbulktankfill,•servicetruckfillingoraskidneylooptomaintainclean&dryfuel

Automaticwaterdraincircuitforeasy•24/7unattendedoperation

Auto-electricalphasereversalandsmart•relaycontrolpanelyieldseasy&reliableoperation

Before After

www.hyprofiltration.com

Page 2: COD DIESEL FUEL CONDITIONING - Vision SolutionsDiesel Fuel Cleanliness Requirements - What Has Changed? • Injector pressures have increased from 3,000 psi to over 30,000 psi (electronic).

www.hyprofiltration.com

High Efficiency Coalesence Combined with High Efficiency ParticulateFiltration Keep Diesel Fuel Clean & Dry for Combustion Engine Reliability

COD30

AutoAirBleedVent Valve

Multi-Element Coalesce&Separator Housing

CoalesceVessel BypassLoop

Davit&SwingArmLidSupport

NEMA4Control Panel

Coalesce&Pre-FilterVesselsEquippedWithTrueGreentoRedDP Gauges

PressureandDifferential Pressure Gauge Panel

3-WayBypassLineSelectorValve

Coalesceelementfeatures100%syntheticmedia(nocellulosemediareducingcompatibilityrelatedelementfailures).

Dual-stage separator andpolishingfilterelement features waterbarrierandhighefficiencyglassmediapost-filtration.

Highefficiencycorelesspre-filteryieldslowerthantargetISOFluidCleanlinessCodeswhileextendingcoalesceelementlife!

Page 3: COD DIESEL FUEL CONDITIONING - Vision SolutionsDiesel Fuel Cleanliness Requirements - What Has Changed? • Injector pressures have increased from 3,000 psi to over 30,000 psi (electronic).

www.hyprofiltration.com

COD

COD200X (Non-Powered)

High Flow Pre-Filter with Coreless Filter Element (TopLoading)

Multi-Element Coalesce&Separator Housing

MechanicalAuto-WaterDrainValveforCODXNon-PoweredCoalesceSkids.

TotalizingWaterMeter

FCLCOD Series Portable Diesel Conditioning Cart

Idealforserviceorientedstand-bydieseltanks(i.e.hospitals).

Removeswaterandparticulate.

Page 4: COD DIESEL FUEL CONDITIONING - Vision SolutionsDiesel Fuel Cleanliness Requirements - What Has Changed? • Injector pressures have increased from 3,000 psi to over 30,000 psi (electronic).

www.hyprofiltration.com

Diesel Fuel Cleanliness Requirements - What Has Changed?Injectorpressureshaveincreasedfrom•3,000psitoover30,000psi(electronic).FuelInjectorsarenowasophisticated•(expensive)electronicenginecomponent.Dieselfuellubricityandfuelenergycontent•hasdecreasedsignificantlywithnewUltraLowSulfurDieselfuels.WatercontaminationinULSDfuelsleadsto•acceleratedmicrobialgrowth.

Enginemanufacturershavelearnedthat•ultrafineparticlesathigherpressuresarecausingprematurefailures(warranty).Fuelinjectorandpumplifehasdecreased•yieldingmoreunplanneddowntimeandlostproduction.Watercontaminationisalsoamajorcause•ofcombustionenginefailureandfuelefficiencyloss.

Before After Failed Fuel Injectors

Hy-Pro LF Style Filter Vessels Installed on Service Truck and Fuel Dispensing

Page 5: COD DIESEL FUEL CONDITIONING - Vision SolutionsDiesel Fuel Cleanliness Requirements - What Has Changed? • Injector pressures have increased from 3,000 psi to over 30,000 psi (electronic).

www.hyprofiltration.com

COD

Intuitive Design Makes Hy-Pro Skids Easy to Operate.Operator Friendly Smart Relay - Smartrelayenabledcontrolpanelperformscontrolledstart-up&shut-downroutinesforeaseofoperationandkeepsoperatorsoutofthecontrolbox.Includesmachinedrainsequence&automaticphasereversal(internallycontrolled,noguessworkorswitchtothrow).Systemstatusisreportedwithilluminatedlightsorsequencesofflashinglights.

Variable Frequency Drive Speed Control (Optional) - VFDcontrolledvariablespeedoptimizescoalesceefficiencyrelativetofluidtemperaturebyrunningsloweruntiloptimumoiltemperatureisachieved.Idealforhighflowsystems(i.e.100gpm)whereVFDcanbeusedtoprovideagradualstart.Smartrelaycanbeprogrammedtotaketemperaturesensorinputandautomaticallyadjustflowforoptimumperformance.

Feature Description

EasyAccessSamplePorts Monitorfuelconditionwithsampleportslocatedbeforethepre-filterandafterthecoalescestage.

SaferServicePlatform Largersafeplatformwithrailingandremovablegridforeasyaccesstoserviceablecomponents.

HighSinglePassEfficiency Highefficiencymediadesignyieldsnearly100%singlepasswaterremovalefficiency.#2dieselnear50ppminonepass.

AutoWaterDrain Idealforcontinuousandunattendedoperation.Maximizesuptime(24/7operation).

GravityFloatLevelControlAutodrainandhighwatersensorleveldetectionbasedonthermalconductivityoffluid(solidstateprobes).Nomovingpartstofailorservice.

FlexibleDesign&Dimensions Flexibledimensionsandprocessarrangementtosuityourapplication(Welistentowhatyouwant).

PleatedCoalesceElement(allsyntheticmedia)

Pleatedcoalesceelementsyieldmoreefficientwatercoalescethantraditionalwrappedbundesigns.

CombinationPost-Filter&Separator Element(allsyntheticmedia)

HighefficiencypleatedglasspostfilterwithinnovativeseparatorsleeveknocksoutwaterandconsistentlydeliverslowerISOcleanlinesscodes.

True DP Gauges with Green to RedDisplay

TruegreentoredDPgaugesprovidevisualconditioncheckandcontrolpanelsignal.Sensorsarelocatedinthevesselsformostaccurateelementconditionmonitoring.

Longer Element Life Coalesceandseparatorroutinechangeinterval1yearorchangeon element DPindicationforcontaminatedsystems.

CorelessPre-filter Corelesspre-filterelementfeaturesb5[c]>1000efficiencyandintegralbypassvalve(newvalvewitheachelementchange).

TotalizingWaterMeter(optional) Trackamountofwaterremovedfromthesystemwithoptionaltotalizingwatermeter(canbeintegratedintooptionalPLC).

Page 6: COD DIESEL FUEL CONDITIONING - Vision SolutionsDiesel Fuel Cleanliness Requirements - What Has Changed? • Injector pressures have increased from 3,000 psi to over 30,000 psi (electronic).

www.hyprofiltration.com

DIESEL COALESCE SKID SPECIFICATIONS & SIZING

Model Length Inch (mm)

Width Inch (mm)

Height Inch (mm)

Weight Lbs (Kg)

COD5/10/30 60(1524) 36(914) 72(1828) 1300(590)

COD60/100 60(1524) 42(1066) 80(2032) 1650(748)

COD200 84(2134) 60(1524) 90(2286) 3980(1805)

COD300/400 84(2134) 70(1778) 90(2286) 4990(2263)

COD500/600 96(2439) 84(2134) 90(2286) 6240(2830)

*StandardConnectionANSIFlange(foralternativeconnectiontypesorsizescontactfactory)

COD Filter Elements Utilized by Model*Model Pre-Filter

ElementsCoalesce Elements

Separator/Polish Elements

COD5/10/30 1 1 X HP677L39-3MV* (CombinedElement)COD60/100 1 2xHP731L39-CB 1 x HP582L30-S1MBCOD200 1 3 x HP731L39-CB 2xHP582L30-S1MB

COD300/400 2 6 x HP731L39-CB 3 x HP582L30-S1MBCOD500/600 3 8xHP731L39-CB 5xHP582L30-S1MB

*HP677L39-3MVcombinescoalesceandseparatorelementfunctionsintooneelement

Upgrades Existing Fuel Delivery Systems for Clean & Dry FuelFormanyapplicationsthereisalreadyafueldeliverysysteminplaceforfillingservicetrucksoroff-loadingfromtankerstofueldepotsincludingahighflowcentrifugalpump.TheCODseriesdieselconditioningskidscanbeproducedwithoutpumpingcapabilitiestobeeasilyaddedtoexistingfuelingsystems.

Toeliminatetheneedforpowerontheskiditcanalsobeproducedwithmanualdraincapabilitiesonly,whicheliminatestheneedforsolenoidvalvesandlevelsensingcomponents.

Whenproperlyinstalledthedieselconditioningsystemcanruncontinuouslyasasidelooptoremoveparticlesandwater.Whenitbecomestimetodispensefuelthrowavalveanddispensethroughtheconditioningskidtoensurecleananddryfueleverytime.

COD5 Custom(Manual Water Drain)

Page 7: COD DIESEL FUEL CONDITIONING - Vision SolutionsDiesel Fuel Cleanliness Requirements - What Has Changed? • Injector pressures have increased from 3,000 psi to over 30,000 psi (electronic).

www.hyprofiltration.com

CODWATER & PARTICULATE REMOVAL PERFORMANCE

Element Synergy - DFEratedG8Dualglasspre-filterremovesparticulatebeforeenteringthecoalescevesselwithhighefficiencyb5[c]>1000media.Oilentersthetwostagevesselpassingfirstthroughthecoalesceelementswherewaterdropletsformandfall.Inthesecondstageofthecoalesceprocessoilpassesthroughthecombinationseparator/polishelementwheretheremainingwaterdropletsareblockedthenfalltothebottomofthecoalescevesseltobeejectedbytheauto-waterdraincircuit.Theseparator/polishelementsalsofeatureb2.5[c]>1000G8Dualglassmediacreatingtwopassesthroughhighlyefficientglassmediaelements.

A properly sized Hy-Pro Coalesce Skid will deliver diesel fuel cleanliness codes of 15/13/10 and better. Maintain water levels at or slightly below a typical saturation level of 50 ppm.

Coalesce Elements HP731L39-CB (No Cellulose) - Hy-ProCoalesceelementscontainnocellulosemediawhichcanbeattackedbyhighwatercontentresultinginmediamigrationandalossofcoalescenceefficiency.Threadedendcaplocksintothehousingwithoutanywashers,screws,ornutstodropintothebottomofthecoalescevessel.Thepleatedsyntheticconfigurationmaximizessurfaceareaandiscontainedbyarigidsupporttube.Therearenowrappedouterlayerstogetsoggyandshedfibersintotheoil.

Separator - Polishing Elements (No Cellulose) HP582L30-S1MB - Awaterseparatingouterwrapknocksoutremainingwaterdropletswhichshedtothebottomofthereservoir.ThepleatedG8DualglassmediapackdownstreamofthewaterbarrierremovessolidcontaminanttoyieldsupercleananddryfluidleavingtheHy-Procoalesceskid.

The b2.5[c] > 1000 final element also reduces thepopulation of sub-micronic insoluble particles thatcontribute to microbial growth and abrasive wear.

Integral Bypass Loop - Itisnotuncommontoexperiencehighlevelsofwaterindieselstoragebulktanks.Hy-Prodieselconditioningskidscanremovehighquantitiesofgrosswaterinasinglepass,butifyouneedtopumpdownfreewaterfromthetankbottomorheavilycontaminatedfluidusethecoalescehousingbypasslooptopumparoundthecoalescevesselandpreserveelementlife.Avoidpushingstraightwaterthroughthecoalescehousing.

COD300COD5-10

Page 8: COD DIESEL FUEL CONDITIONING - Vision SolutionsDiesel Fuel Cleanliness Requirements - What Has Changed? • Injector pressures have increased from 3,000 psi to over 30,000 psi (electronic).

-

www.hyprofiltration.com

DIESEL COALESCE SKID PART NUMBER GUIDE

Table 1 Flow RateCode gpm (lpm)5 5(19)

10 10(38)

30 30(113)

60 60(225)

100 100(378)

200 200(757)

300 300(1135)

400 400(1514)

500 500(1892)

600 600(2271)

Other CallFactory

Table2Power Options

Code

x

Non-PoweredCOD:Nopump-motorcomboorelectricalcontrols.Suitableforaddingtoexistingfueldelivery

systemwithexistingpressureandflow.Autowaterdrainoptionisall

mechanical.Minimumpressurerequirement70psi(5bar)

12 120VAC,1P,60Hz(COD5&10Only)

E1 120VAC,1P,50Hz(COD5&10Only)

E2 230VAC,1P,60Hz(COD5&10Only)

E3 230VAC,1P,50Hz(COD5&10Only)

32 320VAC,3P,50Hz

38 380VAC,3P,50Hz

41 415VAC,3P,50Hz

46 460VAC,3P,60Hz

52 525VAC,3P,50Hz

57 575VAC,3P,60Hz

Table 3 Seal MaterialCode

V Viton(Standard)

Other CallFactory

*Recommendedoptions

*+Qoptionrepair&spareskitincludesseveralitemssuchasfuses,commonrelay,panelbulb,replacementelementsetforcoalescechamber&particulatehousing.

FCE-COD-032410

Table Special OptionsCode (Addoptionstop/ninordertheyappearintable)

8 8”SolidWheelUpgradeA* AutoWaterDrain(ManualDrainIncluded)B AdjustableCoalesceVesselBypassLoopC CEMark+InternationalCrating

H Manual Reset Hour Meter(InAdditiontoStandardNon-ResetHourMeter)

K SightFlowIndicator(WheelType)L LiftingEyeKitM WaterDischargeTotalizingMeterP PLCTouchScreenControl(DoesnotIncludeVFD)

Q*+ MaintenanceSparesandRepairKitT* HoseKit(Suction&ReturnHoses+Wands)U Electricalcord50’withoutPlug(13Meter)X ExplosionProof(ConsultFactory)Y VariableSpeedControl(VFDDrivePLCIncluded)Z* On-SiteStartUpTraining(1x10HourShift)

COD FlowRate Power Seal Options

Table 1 Table4Table 3Table2

-