Top Banner
SUPERMARKETS - Efficiency, quality and reliability built-in all our ecofriendly products CO 2 TRANSCRITICAL REFRIGERATION SYSTEM
12

CO 2 TRANSCRITICAL REFRIGERATION SYSTEM

Oct 30, 2021

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: CO 2 TRANSCRITICAL REFRIGERATION SYSTEM

SUPERMARKETS-

Efficiency, qual i ty and re l iabi l i tybui l t- in a l l our ecofr iendly products

CO2

TRANSCRITICALREFRIGERATION

SYSTEM

Page 2: CO 2 TRANSCRITICAL REFRIGERATION SYSTEM

PASSIONINNOVATION

THOROUGHNESS

LEADER IN HIGH PRESSURE CO2 COOLINGAND REFRIGERATION SYSTEMS

INNOVATIVE COOLING SOLUTIONS BUILTFOR ENVIRONNEMENTAL SUSTAINABILITY

WE OFFER—

Design and engineering

Manufacturing

Project management

Commissioning andhelp desk 24/7

WE SERVE—

Industrials

Supermarkets

Sports centers

Data centers

WE ARE—

Working to make

Eco-friendly refrigeration

a global standard

Page 3: CO 2 TRANSCRITICAL REFRIGERATION SYSTEM

CO2 solution by Carnot : a smart, ecofriendly and profitable choice

PROVEN EFFICIENCYFOR MAJOR SAVINGS

Superior quality, performance and energy stability;

Flawless redesign to replace existing R-22 solutions;

Financial savings of up to 50% year after year due to the reduction of energy costs, maintenance and service costs and the elimination of refrigerant fees.

Made by the most experienced company in CO2 transcritical solutions in North America, the CO2 refrigeration system by Carnot is the smart choice for owners of warehouses and distribution centers.

03

ENERGY CONSUMPTION PROFILEOF THE AVERAGE SUPERMARKET

ANNUAL ENERGY CONSUMPTION SAVINGSIN OUR SUPERMARKETS

53%22%

13%

9%2%

1%

Source : U.S. Energy Information Administration

REFRIGERATION

LIGHTING

HEATING

OTHER

VENTILATION

COOLING

CARNOT SYSTEM

HFC SYSTEM

kW

280 000

270 000

260 000

250 000

240 000

230 000

220 000

210 000

NOV. DEC. JAN. FÉV. MARCH APRIL MAY JUNE JULY AUG. SEPT.

Page 4: CO 2 TRANSCRITICAL REFRIGERATION SYSTEM

TWO STAGE TRANSCRITICAL CO2

04

CompressorStage

CoolingCapacity

[Tons] [°F] / [°C] [°F] / [°C] 50/10 55/12.7 60/15.5 65/18.3 70/21.1 75/23.8 80/26.6 85/29.4 85 GC

Evaporating Temperature

Condensing Temperature

GasCooling

35Low Stage [LS] -20 / -29

Capacity[Tons]

Capacity [Tons][LS THR + HS Load]

35 35 35 35 35 35 35 35 35

kW 21 21 21 21 21 21 21 21 21

THR[MBH] 492 492 492 492 492 492 492 492 492

100High Stage [HS] 23 / -5

141 141 141 141 141 141 141 141 141

kW 62 71 82 94 108 124 143 169 179

TotalkW 83 92 103 115 129 145 164 190 200

SystemCOP 5.77 5.17 4.64 4.15 3.70 3.29 2.90 2.51 2.38

Heat Reclaim MBH 500 500 500 500 500 500 500 500 500

COP w/HR 7.55 6.77 6.07 5.43 4.85 4.31 3.79 3.28 3.12

Ejector Defrost COP w/HR 7.78 6.98 6.26 5.60 5.00 4.44 3.91 3.39 3.21

1 Capacity [Tons] [LS THR + HS Load]

Page 5: CO 2 TRANSCRITICAL REFRIGERATION SYSTEM

CO2 technology by Carnot : a powerful refrigeration system

POWERFUL TECHNOLOGY,QUITE SIMPLY

Modular solution designed bya qualified engineering team;

Process optimization for increased efficiency;

Simplified quick-plug installation;

On-site assistance for equipment start-up;

Complete training for technical staff;

Fully automated system.

A SMART SUSTAINABLEBUSINESS DECISION

Harmless refrigerant reduces or eliminates risk of facing environmental or health and safety restrictions in the future;

Equipment outlasts conventional installations;

Substantial financial savings are generated throughout equipment life;

Significant reduction in greenhouse gases (GHG);

Solution is eligible for current LEED programs.

05

« VERY HIGH QUALITY AND RELIABLE REFRIGERATION SYSTEM AT A LOW MAINTENANCE COST. »

JOCELYN FORGUESIGA Brompton owner

Page 6: CO 2 TRANSCRITICAL REFRIGERATION SYSTEM

CO2 solution by Carnot : a smart, ecofriendly andprofitable choice

06

OFF-TIME EJECTOR DEFROST

TIME

°C

8

7

6

5

4

3

2

1

0

-1

-2

-3

-4

Made by the most experienced company in CO2 transcritical solutions in North America, the CO2 refrigeration system by Carnot is the smart choice.

FOZEN COUNTERS LT/HOT GAS DEFROST

Defrost of low temperature evaporators is supplied by the hot gases released by the low temperature compressors. Compared to electrical defrost, this method has many advantages, such as:

- Reduction of energy consumption;

- Significant increase in product life cycle;

- Definite improvement in the product’s appearance.

REFRIGERATED COUNTERS MT/ACCELERATED PASSIVE DEFROST

This defrost method allows the evaporators of a counter to defrost while remaining in refrigeration mode. Compared to electrical or hot gas defrost, this method has the following advantages:

- Electrical components not required;

- Better product temperature stability.

Page 7: CO 2 TRANSCRITICAL REFRIGERATION SYSTEM

Defrost technologies and meatproduct temperature

07

PRODUCT TEMPERATURE IN DEFROST CHART

OFF-TIME DEFROST 4 X 45 MIN. DEFROST PER DAY + 5 MIN. DRIP TIME°F

40

39

38

37

36

35

34

33

32

31

30

00 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 HRS

°F

40

39

38

37

36

35

34

33

32

31

30

00 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 HRS

HOT GAS DEFROST 4 X 12 MIN. DEFROST PER DAY + 5 MIN. DRIP TIME

°F

40

39

38

37

36

35

34

33

32

31

30

00 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 HRS

EJECTOR DEFROST 4 X 20 MIN. DEFROST PER DAY + 5 MIN. DRIP TIME

SUPER HEATED

GAS

VALVE 0%

OPEN

AIR FLOW

DISCHARGE HOT GAS

VALVE 100% OPEN

FAN OFF /NO AIR FLOW

FLASH GAS

VALVE 100% OPEN

FAN OFF /NO AIR FLOW

Page 8: CO 2 TRANSCRITICAL REFRIGERATION SYSTEM

CO2 solutions by Carnot : a smart, ecofriendly andprofitable choice

08

MADE BY THE MOST EXPERIENCED COMPANY IN CO2 TRANSCRITICAL SOLUTIONS IN NORTH AMERICA, THE CO2 REFRIGERATION AND COOLING SYSTEMS ARE THE SMART CHOICE.

59 °F

15 °C

131 °F

55 °C

RCIntelligent is a smarter way to use the rejected energy of your process: system is composed of various components that recover energy rejected by the process in a smart and strategic way.

HEAT RECOVERY AVAILABLE WITHCARNOT CO2 TRANSCRITICAL SYSTEMS

kW H

EATI

NG

/ k

W R

EFRI

GER

ATI

ON

DISCHARGE PRESSURE [PSIG]CONDENSING TEMPERATURE [°F / °C]

DISCHARGE TEMPERATURE [°F / °C]

1.4

1.2

1.0

0.8

0.6

0.4

0.2

0.079865

129

87072

144

94378

149

101683

169

1088-

181

1161-

192

1233-

204

1306-

216

1378-

220

1451-

237

1523-

248

WATER PREHEATINGPERMAFROSTAIR PREHEATING (HVAC)

300 kW≤ 59°F≤ 15°C

490 kW≤ 95°F≤ 35°C

240 kW≤ 131°F≤55°C

290 kW≤ 171°F≤ 77°C

190 °F / 87.7 °C

240 °F / 115.5 °C

WATER FOR HEATINGAMBIANT HEATINGFLOOR HEATING

STEAM BOILERDESICCANT WHEELPASTEURIZATIONDEHUMIDIFICATION

Maximum heating profile of 1000 kWfor refrigeration load of 3,415,00 Btu/h.Examples of heating combinations:1. 1320 kW > 59°F / 15 °C2. 530 kW > 131°F / 55 °C and 790 kW > 59°F / 15 °C3. 290 kW > 171°F / 77 °C and 1030 kW > 59°F / 15 °C

DOMESTIC HOT WATERDEHUMIDIFICATION

150 °F / 65.5 °C

1

2

3

95 °F

35°C

171 °F

77 °C

Page 9: CO 2 TRANSCRITICAL REFRIGERATION SYSTEM

OPTIMIZED TECHNOLOGY, SUPERIOR RELIABILITY AND SAFETY

Designed in compliance with the highest quality standards in the industry;

Strict quality control in a controlled environment;

Highly reliable processes tried and tested in the most extreme conditions;

POWERFUL TECHNOLOGY,QUITE SIMPLY

Remote controlled equipment and alarm system;

Real-time monitoring and performance reports by a highly qualified team;

24/7 technical support, quick and efficient interventions.

EXCELLENT SERVICE, QUICK RESPONSE AND VERY COMPETENT STAFF.

Alarm RepairDetectiontime

Customerreaction

Phonecall

Techniciandiagnosis

35% FASTER INTERVENTION

STANDARD INTERVENTION

Alarm RepairRemotecontrol

Diagnosisand attempt to repairremotely

75% of alarms resolvedhere

Technicianinterventionon-site

CARNOT INTERVENTION

09

Page 10: CO 2 TRANSCRITICAL REFRIGERATION SYSTEM

CO2 technology by Carnot : customize your system

10

HEAT RECOVERY / RCINTELLIGENT

Reuse the energy created by your process using a custom heat recovery strategy for major financial savings year after year.

PARALLELCOMPRESSION

Increased efficiency.

GAS COOLER/ CONDENSER

Different options available for optimal performance and durability.

ACCELERATEDPASSIVE DEFROST

This method allows the medium temperature evaporators to defrost without adding unnecessary heat to the refrigeration system for annual savings and better temperature stability.

24/7 REMOTE MONITORINGAND IMPREMENTATION

Real-time technical support.

REMOTECONTROL

To closely monitor your process using your smartphone or computer.

TURNKEY INSTALLATION

For peace of mind, done by professionals to meet your needs, from design to start-up.

HOT GAS DEFROST

Defrost of low temperature evaporators is supplied by the hot gases released by the low temperature compressors for annual energy savings and a longer product life cycle.

Page 11: CO 2 TRANSCRITICAL REFRIGERATION SYSTEM

Carnot has proven itself regarding the performance of its CO2 transcritical refrigeration system. With the longest-lasting legacy of high quality demonstrations across North American and Europe since 2008, CO2 refrigeration technology by Carnot has set standards with its efficiency, profitability, sustained performance in the most extreme conditions, simplicity and operational reliability.

Carnot: a pioneer in transcritical CO2 and cooling systems

10

NOTEWORTHY FACTS

Installations performed throughout North-America and Europe;

Daily savings for our clients;

Highly qualified engineers who are constantly trying to set higher standards for CO2 refrigeration technology;

Standards and certifications including CSA, UL and CE;

Awards and recognition from recognized organizations such as ASHRAE and EPA;

Competent customer service team focused on customer satisfaction.

Page 12: CO 2 TRANSCRITICAL REFRIGERATION SYSTEM

SUPERMARKETS-

CARNOT

8500, boul . Industr ie lTrois-Rivières, Québec

Canada G9A 5E1

+ 1 855 376-5959

sales@carnotrefr igeration.comwww.carnotrefrigeration.com

« CO2 IS NOURISHMENT FOR TREES : SYNTHETIC MOLECULES ARE NOT. »

MARC-ANDRÉ LESMERISESCEO of Carnot , United Nations conference