June 2004 Andrea Gaddi, PH-CMI CMS rack system CMS rack system Photo - JPEG decompressor are needed to see this picture. DSS TS/EL Power distributi RSS TS/EL Bus PLC ST/MA AFDCIE DCS RSS loop fire extinguisher (opt from monitoring boar Premium PLC
10

CMS rack system

Feb 01, 2016

Download

Documents

CMS rack system. Magnetic Stray Field in UXC. How to feed power to Racks. UXC. USC. Breaker + PLC. Power Supply. AC/DC converter. 400 Hz. 50 Hz. Rack Location - I. Rack Location - II. Rack Location - III. Rack Location - IV. Rack Standard Components. Power Cabinet. Power Cabinet. - PowerPoint PPT Presentation
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: CMS rack system

June 2004 Andrea Gaddi, PH-CMI

CMS rack systemCMS rack system

QuickTime™ and aPhoto - JPEG decompressor

are needed to see this picture.

DSS

TS/EL Power distribution

RSS

TS/EL Bus

PLC

ST/MAAFDCIE

DCS

RSS loop

PDC breakers status

fire extinguisher (option)

from monitoring board

Premium PLC

thermal switch + crate monitoring

Page 2: CMS rack system

June 2004 Andrea Gaddi, PH-CMI

Magnetic Stray Field in UXCMagnetic Stray Field in UXC

Page 3: CMS rack system

June 2004 Andrea Gaddi, PH-CMI

How to feed power to RacksHow to feed power to Racks

QuickTime™ and aPhoto - JPEG decompressor

are needed to see this picture.

QuickTime™ and aPhoto - JPEG decompressor

are needed to see this picture.

USC UXC

50 Hz

400 Hz

PowerSupply

AC/DC converter

Breaker + PLC

Page 4: CMS rack system

June 2004 Andrea Gaddi, PH-CMI

Rack Location - IRack Location - I

Page 5: CMS rack system

June 2004 Andrea Gaddi, PH-CMI

Rack Location - IIRack Location - II

Page 6: CMS rack system

June 2004 Andrea Gaddi, PH-CMI

Rack Location - IIIRack Location - III

Page 7: CMS rack system

June 2004 Andrea Gaddi, PH-CMI

Rack Location - IVRack Location - IV

Page 8: CMS rack system

June 2004 Andrea Gaddi, PH-CMI

TurbinesPower Cabinet

Fan tray

Deflector Coolingmanifolds

Turbines

Power Cabinet

Electronics Crate

Heat Exchanger

Deflector

Cooling manifolds

Electronics Crate

Rack Standard ComponentsRack Standard Components

Page 9: CMS rack system

June 2004 Andrea Gaddi, PH-CMI

Power Distribution ControlPower Distribution Control

QuickTime™ and aPhoto - JPEG decompressor

are needed to see this picture.

DSS

TS/EL Power distribution

RSS

TS/EL Bus

PLC

ST/MAAFDCIE

DCS

RSS loop

PDC breakers status

fire extinguisher (option)

from monitoring board

Premium PLC

thermal switch + crate monitoring

Page 10: CMS rack system

June 2004 Andrea Gaddi, PH-CMI

Time ScheduleTime Schedule

Detector racks: from Sept 04

USC hand-over: 14 June 04USC infrastructures: Jul 04 to Feb 05USC control room racks: March to Jun 05USC control rooms crates: from July 05

UXC hand-over: 01 Nov 04UXC infrastructures: Jan to Dec 05UXC racks: Jan to March 06UXC crates: from Apr 06