Top Banner
Lutz Schweikhard ECTI, 2010-09, Redworth Hall Institut für Physik Ernst-Moritz-Arndt-Universität 17487 Greifswald Germany ClusterTrap: A Penning Trap for Cluster Research (Ion Trapping for Cluster Research) ClusterTrap
72

ClusterTrap: A Penning Trap for Cluster Research · ClusterTrap: A Penning Trap for Cluster Research ... H. Stolzenberg et al., PRL 1990. ... CID. 2. selection. CID.

Nov 15, 2018

Download

Documents

vannga
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: ClusterTrap: A Penning Trap for Cluster Research · ClusterTrap: A Penning Trap for Cluster Research ... H. Stolzenberg et al., PRL 1990. ... CID. 2. selection. CID.

Lutz Schweikhard

ECTI, 2010-09, Redworth Hall

Institut für PhysikErnst-Moritz-Arndt-Universität

17487 GreifswaldGermany

ClusterTrap: A Penning Trap for Cluster Research

(Ion Trapping for Cluster Research)

ClusterTrap

Page 2: ClusterTrap: A Penning Trap for Cluster Research · ClusterTrap: A Penning Trap for Cluster Research ... H. Stolzenberg et al., PRL 1990. ... CID. 2. selection. CID.

Overview

Other traps and applicationsFT-ICR MS, precison MS of radionuclides,

EBIT, (electrostatic ion-beam traps => Wada)

ClusterTrapwhy? how? what?

Other cluster-storage devices

Page 3: ClusterTrap: A Penning Trap for Cluster Research · ClusterTrap: A Penning Trap for Cluster Research ... H. Stolzenberg et al., PRL 1990. ... CID. 2. selection. CID.

-

++++

+

ωred.cyc(+)

----

FT-ICR MS = FTMSFourier Transform (Ion Cyclotron Resonance) Mass Spectrometry

Detection of Ion Motion (after broad-band excitation)

Courtesy of Roland Jertz, Bruker Daltonik/Bremen

Page 4: ClusterTrap: A Penning Trap for Cluster Research · ClusterTrap: A Penning Trap for Cluster Research ... H. Stolzenberg et al., PRL 1990. ... CID. 2. selection. CID.

Protein A (44 kDa) Broad-Band Spectrum

800 1000 1200 1400 m/z

57+ 27+

46+

970.4 970.8 971.2 m/z

Δm = 0.02176 u1/Δm = 45.964 / u

mass = 44610 u46+

isotopologues

charge states

Courtesy of Roland Jertz, Bruker Daltonik/Bremen

Page 5: ClusterTrap: A Penning Trap for Cluster Research · ClusterTrap: A Penning Trap for Cluster Research ... H. Stolzenberg et al., PRL 1990. ... CID. 2. selection. CID.

FT-ICR MS systems in use (as a function of time)

A.G. Marshall and LS, IJMS 118/119 (1992)

Typically > 500 k€ a piece

Three independent companies developing and selling FT-ICR systems

Page 6: ClusterTrap: A Penning Trap for Cluster Research · ClusterTrap: A Penning Trap for Cluster Research ... H. Stolzenberg et al., PRL 1990. ... CID. 2. selection. CID.

Overview

Other traps and applicationsFT-ICR MS, precison MS of radionuclides,

EBIT, (electrostatic ion-beam traps => Wada)

ClusterTrapwhy? how? what?

Other cluster-storage devices

Page 7: ClusterTrap: A Penning Trap for Cluster Research · ClusterTrap: A Penning Trap for Cluster Research ... H. Stolzenberg et al., PRL 1990. ... CID. 2. selection. CID.

Precision mass measurements of short-lived nuclides

ISOLTRAP AT ISOLDE/CERN

141mSm, E=175keV

141gSm

Eu Sm Pm Nd Pr

A=141

Precision Trap:Determination of cyclotron

frequencyIsomer separation

Preparation Trap:Accumulation

Cooling Isobar separation

RetardationCooling

AccumulationBunching

1m

1cm

5cm

60 000 V

B = 4.7 T

B = 6 T

Linear RFQ trap

Setup:H. Stolzenberg et al., PRL 1990G. Bollen et al., NIM A 1996H. Raimbault-Hartmann et al., NIM B ‘97F. Herfurth et al., NIM A 2001

60keV ISOLDE

ion beam

Page 8: ClusterTrap: A Penning Trap for Cluster Research · ClusterTrap: A Penning Trap for Cluster Research ... H. Stolzenberg et al., PRL 1990. ... CID. 2. selection. CID.

ISOLTRAP setup

Recent exp. results, e.g.: PRL 98, 162501(2007); 100, 072501(2008); 101,252502(2008); 101, 262501(2008); 102, 112501(2009); 105, 032502(2010)

buncherpreparation

trap

precisiontrap

electrostaticion-beam trap

as isobar separatorposter 52

Page 9: ClusterTrap: A Penning Trap for Cluster Research · ClusterTrap: A Penning Trap for Cluster Research ... H. Stolzenberg et al., PRL 1990. ... CID. 2. selection. CID.

9

One of the off-springs: SHIPTRAP at GSI/Darmstadt

Page 10: ClusterTrap: A Penning Trap for Cluster Research · ClusterTrap: A Penning Trap for Cluster Research ... H. Stolzenberg et al., PRL 1990. ... CID. 2. selection. CID.

First direct mass measurements above uranium

-3 -2 -1 0 1 2 3

72

74

76

78

80

82

84

86

88

90

92

Mea

n tim

e of

flig

ht /

μsExcitation frequency / Hz - 850012

253No2+

M. Block et al., Nature 463 (2010) 785252-254No (Z=102) with production ratesOf 0.5 to 2 atoms/s(at MeV/nucleon)

meanwhilealso Lr(Z=103)

additional posternext to poster 52

253No2+

Page 11: ClusterTrap: A Penning Trap for Cluster Research · ClusterTrap: A Penning Trap for Cluster Research ... H. Stolzenberg et al., PRL 1990. ... CID. 2. selection. CID.

Overview

Other traps and applicationsFT-ICR MS, precison MS of radionuclides,

EBIT, (electrostatic ion-beam traps => Wada)

ClusterTrapwhy? how? what?

Other cluster-storage devices

Page 12: ClusterTrap: A Penning Trap for Cluster Research · ClusterTrap: A Penning Trap for Cluster Research ... H. Stolzenberg et al., PRL 1990. ... CID. 2. selection. CID.

EBIT: Electro-Beam Ion Trapor How to produce and confine highly-charged ions?

Electrostatic trapping is not possible by static electric fields only

unless space charge allowed

Here by compression of an electron beam by strong B-field

Replace Laplace: Δφ = 0by Poisson: Δφ = ρ/ε0

Page 13: ClusterTrap: A Penning Trap for Cluster Research · ClusterTrap: A Penning Trap for Cluster Research ... H. Stolzenberg et al., PRL 1990. ... CID. 2. selection. CID.

X-ray emission from cometsdue to charge transfer from highly-charged ionsof solar wind colliding with neutral atoms of the comets

Such reactions as well as lifetimes of metastable statesare studied in the “magnetic-trapping mode” of EBIT

Lisse et al., Science 274, 205 (1996)

P. Beiersdorfer, LS et al.,RSI 67, 3818 (1996)

Page 14: ClusterTrap: A Penning Trap for Cluster Research · ClusterTrap: A Penning Trap for Cluster Research ... H. Stolzenberg et al., PRL 1990. ... CID. 2. selection. CID.

Overview

Other traps and applications

ClusterTrapclusters? why? how? what?

Other cluster-storage devices

Page 15: ClusterTrap: A Penning Trap for Cluster Research · ClusterTrap: A Penning Trap for Cluster Research ... H. Stolzenberg et al., PRL 1990. ... CID. 2. selection. CID.

From Atoms to Bulk Matter: Clusters

CLUSTER

atom/molecule

condensed matter

surface

one

few

many

T.P. Martin (1984)

Page 16: ClusterTrap: A Penning Trap for Cluster Research · ClusterTrap: A Penning Trap for Cluster Research ... H. Stolzenberg et al., PRL 1990. ... CID. 2. selection. CID.

Scaling Laws

G(∞)

R, NG(N,R)

Large Small

R−α, N−β

Small Clusters:Quantum Sizeand SurfaceEffects

Large ClustersSmoothLiquid Drop

Medium

G(1)

fromRoy L. Johnston:Atomic and Molecular Clusters(London, New York, 2002)

Behaviour

Page 17: ClusterTrap: A Penning Trap for Cluster Research · ClusterTrap: A Penning Trap for Cluster Research ... H. Stolzenberg et al., PRL 1990. ... CID. 2. selection. CID.

Noble gas clusters: geometric shells

Mackay IcosahedraO. Echt et al. (PRL,1984)

Page 18: ClusterTrap: A Penning Trap for Cluster Research · ClusterTrap: A Penning Trap for Cluster Research ... H. Stolzenberg et al., PRL 1990. ... CID. 2. selection. CID.

Jellium model

electronic shellsW. D. Knight et al. (PRL, 1984)

Metal clusters

Experimental distinction betw. geom. and electr. effects: charge-state dependence

Page 19: ClusterTrap: A Penning Trap for Cluster Research · ClusterTrap: A Penning Trap for Cluster Research ... H. Stolzenberg et al., PRL 1990. ... CID. 2. selection. CID.

Why cluster ions?

W. D. Knight et al. (1984)

Size selection by mass spec. as first step for detailed studies !mass spec. also for reaction product analysis => MS-MS

Page 20: ClusterTrap: A Penning Trap for Cluster Research · ClusterTrap: A Penning Trap for Cluster Research ... H. Stolzenberg et al., PRL 1990. ... CID. 2. selection. CID.

Overview

Other traps and applications

ClusterTrapclusters? why? how? what?

Other cluster-storage devices

Page 21: ClusterTrap: A Penning Trap for Cluster Research · ClusterTrap: A Penning Trap for Cluster Research ... H. Stolzenberg et al., PRL 1990. ... CID. 2. selection. CID.

InteractionPartners

Why cluster trapping?(as compared to beams)

- extended interaction periods- extended reaction periods- multi-step preparation

Reactionsand

atoms

molecules

electrons

photons

clusters

ions

dissociation(evaporation, fission)

ionization recombinationelectron attachment

adsorption

radiative cooling

fusion

Page 22: ClusterTrap: A Penning Trap for Cluster Research · ClusterTrap: A Penning Trap for Cluster Research ... H. Stolzenberg et al., PRL 1990. ... CID. 2. selection. CID.

Overview

Other traps and applications

ClusterTrapclusters? why? how? what?

Other cluster-storage devices

Page 23: ClusterTrap: A Penning Trap for Cluster Research · ClusterTrap: A Penning Trap for Cluster Research ... H. Stolzenberg et al., PRL 1990. ... CID. 2. selection. CID.

Experimental set-up of ClusterTrap @ Greifswald

S. Becker et al., RSI (1995)LS et al., EPJ D (2003)

Page 24: ClusterTrap: A Penning Trap for Cluster Research · ClusterTrap: A Penning Trap for Cluster Research ... H. Stolzenberg et al., PRL 1990. ... CID. 2. selection. CID.

Experimental set-up of ClusterTrap @ Greifswald

S. Becker et al., RSI (1995)LS et al., EPJ D (2003)

Page 25: ClusterTrap: A Penning Trap for Cluster Research · ClusterTrap: A Penning Trap for Cluster Research ... H. Stolzenberg et al., PRL 1990. ... CID. 2. selection. CID.

ClusterTrap

ObergurglNext ECTICERN

GSI

at Univ. ofGreifswald

founded in 1456„full university“ca. 12000 students

Page 26: ClusterTrap: A Penning Trap for Cluster Research · ClusterTrap: A Penning Trap for Cluster Research ... H. Stolzenberg et al., PRL 1990. ... CID. 2. selection. CID.

Trap Electrodes

inner diameter of ring electrode40 mm

Note:Miniaturization is not appreciated !

Page 27: ClusterTrap: A Penning Trap for Cluster Research · ClusterTrap: A Penning Trap for Cluster Research ... H. Stolzenberg et al., PRL 1990. ... CID. 2. selection. CID.

CAPTURE

Typical experimental sequence

Page 28: ClusterTrap: A Penning Trap for Cluster Research · ClusterTrap: A Penning Trap for Cluster Research ... H. Stolzenberg et al., PRL 1990. ... CID. 2. selection. CID.

SELECTION

+ ++

+

Typical experimental sequence

Page 29: ClusterTrap: A Penning Trap for Cluster Research · ClusterTrap: A Penning Trap for Cluster Research ... H. Stolzenberg et al., PRL 1990. ... CID. 2. selection. CID.

INTERACTION(e.g. electron bombardment)

Typical experimental sequence

Page 30: ClusterTrap: A Penning Trap for Cluster Research · ClusterTrap: A Penning Trap for Cluster Research ... H. Stolzenberg et al., PRL 1990. ... CID. 2. selection. CID.

RE-ACTION(e.g. ionization and dissociation)

Typical experimental sequence

Page 31: ClusterTrap: A Penning Trap for Cluster Research · ClusterTrap: A Penning Trap for Cluster Research ... H. Stolzenberg et al., PRL 1990. ... CID. 2. selection. CID.

EJECTION for TOF mass analysis

Typical experimental sequence

Page 32: ClusterTrap: A Penning Trap for Cluster Research · ClusterTrap: A Penning Trap for Cluster Research ... H. Stolzenberg et al., PRL 1990. ... CID. 2. selection. CID.

Overview

Other traps and applicationsFT-ICR MS, precison MS of radionuclides,

EBITs, electrostatic ion-beam traps

ClusterTrapclusters? why? how? what?

Other cluster-storage devices

Page 33: ClusterTrap: A Penning Trap for Cluster Research · ClusterTrap: A Penning Trap for Cluster Research ... H. Stolzenberg et al., PRL 1990. ... CID. 2. selection. CID.

CAPTURE

ACCUMULATION

SELECTION

ELECTRONBOMBARDMENT

A. Herlert et al., J. Electron.Spectrosc. (2000)

time-of-flight spectra (gold clusters)electron bombardment of cations

+ +

+

2+

Page 34: ClusterTrap: A Penning Trap for Cluster Research · ClusterTrap: A Penning Trap for Cluster Research ... H. Stolzenberg et al., PRL 1990. ... CID. 2. selection. CID.

S. Krückeberg et al. (1999)

Electron Impact Ionization/Dissociation of Ag-clusters

observation of both

ELECTRONIC

GEOMETRIC

and

shells

Page 35: ClusterTrap: A Penning Trap for Cluster Research · ClusterTrap: A Penning Trap for Cluster Research ... H. Stolzenberg et al., PRL 1990. ... CID. 2. selection. CID.

Collision Induced Dissociation (CID)

dipole excitation

(Many) collisionswith noble-gas atoms

Page 36: ClusterTrap: A Penning Trap for Cluster Research · ClusterTrap: A Penning Trap for Cluster Research ... H. Stolzenberg et al., PRL 1990. ... CID. 2. selection. CID.

capture/accumulation andelectron bombardment

1. selection

CID

2. selection

CID

CID after first selection

CID of product ions: How do they break apart ?=> decay channels

S. Krückeberg et al., ZPD (1997)

Page 37: ClusterTrap: A Penning Trap for Cluster Research · ClusterTrap: A Penning Trap for Cluster Research ... H. Stolzenberg et al., PRL 1990. ... CID. 2. selection. CID.

CID revisited: At what energy do they break apart ?=> dissociation energies

Krückeberg (EPJD, 1999)

Page 38: ClusterTrap: A Penning Trap for Cluster Research · ClusterTrap: A Penning Trap for Cluster Research ... H. Stolzenberg et al., PRL 1990. ... CID. 2. selection. CID.

Dissociation energies from CID

S. Krückeberg et al., JCP (1999)

Page 39: ClusterTrap: A Penning Trap for Cluster Research · ClusterTrap: A Penning Trap for Cluster Research ... H. Stolzenberg et al., PRL 1990. ... CID. 2. selection. CID.

Dissociation energies from CID

S. Krückeberg et al., PRA (1999)

Page 40: ClusterTrap: A Penning Trap for Cluster Research · ClusterTrap: A Penning Trap for Cluster Research ... H. Stolzenberg et al., PRL 1990. ... CID. 2. selection. CID.

Dissociation energies from CID

However: - impact parameter?

=> energy?- time of collision? 4 5 5 0 5 5 6 0 6 5 7 0 7 5 8 0 8 5

0

2

4

6

8

1 0

1 2

1 4

1 6

1 8

2 0

S n / M

eV

N e u tro n N u m b e r

cf. neutron-separation energies from mass meas.

Cd isotopes

N=50

N=82

Page 41: ClusterTrap: A Penning Trap for Cluster Research · ClusterTrap: A Penning Trap for Cluster Research ... H. Stolzenberg et al., PRL 1990. ... CID. 2. selection. CID.

C. Walther et al., CPL (1996), M. Lindinger et al., ZPD (1997)

Dissociation energies fromTime – resolved photodissociation

Page 42: ClusterTrap: A Penning Trap for Cluster Research · ClusterTrap: A Penning Trap for Cluster Research ... H. Stolzenberg et al., PRL 1990. ... CID. 2. selection. CID.

Walther et al., Z. Phys. D., 1996Lindinger et al., Z. Phys. D., 1997

Hild et al., Phys. Rev. A, 1998

Time – resolved photodissociationDefined

- exitation time and- exitation energy

Page 43: ClusterTrap: A Penning Trap for Cluster Research · ClusterTrap: A Penning Trap for Cluster Research ... H. Stolzenberg et al., PRL 1990. ... CID. 2. selection. CID.

Determination of dissociation energy – in principle

dissociation energy D

excitation withdefined energy

E observationof decay rate

k

modelingk(E,D,…)

inversion

Page 44: ClusterTrap: A Penning Trap for Cluster Research · ClusterTrap: A Penning Trap for Cluster Research ... H. Stolzenberg et al., PRL 1990. ... CID. 2. selection. CID.

excitation withdefined energy

E observationof decay rate

k

modelingk(E,D,…)

inversion

and in praxis: - value of D is model-dependent- value of D is dep. on exc. energy E

Determination of dissociation energy – in principle

Page 45: ClusterTrap: A Penning Trap for Cluster Research · ClusterTrap: A Penning Trap for Cluster Research ... H. Stolzenberg et al., PRL 1990. ... CID. 2. selection. CID.

Observation ofprecursor and

product(s)

allows

observation ofsequential decay

M. Vogel et al., PRL (2001)

Page 46: ClusterTrap: A Penning Trap for Cluster Research · ClusterTrap: A Penning Trap for Cluster Research ... H. Stolzenberg et al., PRL 1990. ... CID. 2. selection. CID.

Quasi model-free determination of D

M. Vogel et al., PRL (2001)

for τ = τ‘: En - Dn - KER = En-1

KER

Dn = En - En-1 - KER

What‘s the trick?

What‘s the pay-off?two coordinated measurements needed

no need to model the residual excitation energy left after the dissociation

Page 47: ClusterTrap: A Penning Trap for Cluster Research · ClusterTrap: A Penning Trap for Cluster Research ... H. Stolzenberg et al., PRL 1990. ... CID. 2. selection. CID.

In practise: perform a couple of measurements

3.47(6)eV

Page 48: ClusterTrap: A Penning Trap for Cluster Research · ClusterTrap: A Penning Trap for Cluster Research ... H. Stolzenberg et al., PRL 1990. ... CID. 2. selection. CID.

Sequential Excitationi.e. pump – probe at up to tens of milliseconds

=> Investigation of Radiative Cooling

C. Walther et al., PRL (1999)

Page 49: ClusterTrap: A Penning Trap for Cluster Research · ClusterTrap: A Penning Trap for Cluster Research ... H. Stolzenberg et al., PRL 1990. ... CID. 2. selection. CID.

Attachment and photodetachment of methanol

G. Dietrich et al.,CPL (1996), …

JCP (2000)

Page 50: ClusterTrap: A Penning Trap for Cluster Research · ClusterTrap: A Penning Trap for Cluster Research ... H. Stolzenberg et al., PRL 1990. ... CID. 2. selection. CID.

Infrared SpectroscopyPhotodetachment

of methanol

G. Dietrich et al., JCP (2000)R. Rousseau et al., CPL (1998)

Detachment energies:M. Vogel et al., JCP (2002)

N /

N0

υ(cm-1)

Resonance of theCO-stretching

mode ofAu9

+CH3OH

Transition fromplanar to

three-dimensionalstructures

Theory

Experiment

Page 51: ClusterTrap: A Penning Trap for Cluster Research · ClusterTrap: A Penning Trap for Cluster Research ... H. Stolzenberg et al., PRL 1990. ... CID. 2. selection. CID.

- Electron-impact ionisation for cationic clusters(see above)

- Electron attachment for anionic clusters

Moving on to further charge states byelectron-cluster interaction:

?e-

Page 52: ClusterTrap: A Penning Trap for Cluster Research · ClusterTrap: A Penning Trap for Cluster Research ... H. Stolzenberg et al., PRL 1990. ... CID. 2. selection. CID.

Dianion production

CAPTURING

Page 53: ClusterTrap: A Penning Trap for Cluster Research · ClusterTrap: A Penning Trap for Cluster Research ... H. Stolzenberg et al., PRL 1990. ... CID. 2. selection. CID.

Dianion production

ACCUMULATION

Page 54: ClusterTrap: A Penning Trap for Cluster Research · ClusterTrap: A Penning Trap for Cluster Research ... H. Stolzenberg et al., PRL 1990. ... CID. 2. selection. CID.

Dianion production

SIZE SELECTION

Page 55: ClusterTrap: A Penning Trap for Cluster Research · ClusterTrap: A Penning Trap for Cluster Research ... H. Stolzenberg et al., PRL 1990. ... CID. 2. selection. CID.

Simultan. storage of clusters, mcluster ≈ 5000 u and electrons, me ≈ 1/2000 u

ELECTRONBATH

A. Herlert et al. (1999)

Page 56: ClusterTrap: A Penning Trap for Cluster Research · ClusterTrap: A Penning Trap for Cluster Research ... H. Stolzenberg et al., PRL 1990. ... CID. 2. selection. CID.

Silver - cluster dianions

Herlert et al., EPJ D (2001)

Page 57: ClusterTrap: A Penning Trap for Cluster Research · ClusterTrap: A Penning Trap for Cluster Research ... H. Stolzenberg et al., PRL 1990. ... CID. 2. selection. CID.

CID (collision-ind. dissociation) is not always a good idea

as charge-changing reactions(here electron emission)can lead to ion loss due to increased motional amplitudes

Herlert et al.IJMS 2004

Page 58: ClusterTrap: A Penning Trap for Cluster Research · ClusterTrap: A Penning Trap for Cluster Research ... H. Stolzenberg et al., PRL 1990. ... CID. 2. selection. CID.

Photoexcitationof dianions

10 ns pulse, λ=355nmE=1mJ

Page 59: ClusterTrap: A Penning Trap for Cluster Research · ClusterTrap: A Penning Trap for Cluster Research ... H. Stolzenberg et al., PRL 1990. ... CID. 2. selection. CID.

Photoabsorption of dianions

branching ratioof decay pathways

(monomer vs.electron emission)

Page 60: ClusterTrap: A Penning Trap for Cluster Research · ClusterTrap: A Penning Trap for Cluster Research ... H. Stolzenberg et al., PRL 1990. ... CID. 2. selection. CID.

0 50 100 150 200 250 300

Al215

3-

Al215

2-

Al215

-

Al250

4-

Al250

3-

Al250

2-

Al250

-

Al280

4-Al

2803-

Al280

2-

Al280

-

atoms / charge100 150 200 250 300 350 400 450 500 550 6000

20

40

60

80

100

20

40

60

80

100

laser excitation at 532nm

Al260-Al260

2-

Al260

3-Al

2604-

Nor

mal

ised

sig

nal i

nten

sity

ToF /μs

no laser Al260

4-

Tetra-(quad-)anionic aluminum clusters

photoexcitationproduction

n = 250

n = 215

n = 280

n = 260

z = 4-

z = 2- z = 1-z = 3-

z = 4-

Laser excitation at 532 nm

N. Walsh et al., J. Phys. B 42 (2009) 154024

Page 61: ClusterTrap: A Penning Trap for Cluster Research · ClusterTrap: A Penning Trap for Cluster Research ... H. Stolzenberg et al., PRL 1990. ... CID. 2. selection. CID.

M. Arndt (Paul trap)S. Bandelow (Paul trap)

Ch. Droese (SHIPTRAP/GSI)F. Martinez (ClusterTrap)Dr. G. Marx (almost all)

M. Rosenbusch (ISOLTRAP/CERN)L. S.

A. Vass(ClusterTrap)B. F. Wienholtz (just started)R. Wolf (ISOLTRAP/CERN)

F. Ziegler (ClusterTrap)

Diploma/Master students: Ch. Breitenfeldt, S. Gierke, S. Knaur

Current Ion Trappersat Greifswald

(and at CERN and GSI)

Thanks also to DFG, BMBF, EU, …

Page 62: ClusterTrap: A Penning Trap for Cluster Research · ClusterTrap: A Penning Trap for Cluster Research ... H. Stolzenberg et al., PRL 1990. ... CID. 2. selection. CID.

We have moved from

Page 63: ClusterTrap: A Penning Trap for Cluster Research · ClusterTrap: A Penning Trap for Cluster Research ... H. Stolzenberg et al., PRL 1990. ... CID. 2. selection. CID.

We have moved to the new building of the Inst. of Physics

Page 64: ClusterTrap: A Penning Trap for Cluster Research · ClusterTrap: A Penning Trap for Cluster Research ... H. Stolzenberg et al., PRL 1990. ... CID. 2. selection. CID.

Current modifications

-+

- +under way i.e.

„construction site“

Page 65: ClusterTrap: A Penning Trap for Cluster Research · ClusterTrap: A Penning Trap for Cluster Research ... H. Stolzenberg et al., PRL 1990. ... CID. 2. selection. CID.

Overview

Other traps and applications

ClusterTrapclusters? why? how? what?

Other cluster-storage devices

Page 66: ClusterTrap: A Penning Trap for Cluster Research · ClusterTrap: A Penning Trap for Cluster Research ... H. Stolzenberg et al., PRL 1990. ... CID. 2. selection. CID.

multi-step reactionsgrowth of benzene from ethylene on iron tetramers

Schnabel et al. (Irion)J. Chem., 1991

Angew. Chem., 1992

repeated selection

and furtherreaction

two [!] cyclessuch as shown

⇒ catalysisresearch

Page 67: ClusterTrap: A Penning Trap for Cluster Research · ClusterTrap: A Penning Trap for Cluster Research ... H. Stolzenberg et al., PRL 1990. ... CID. 2. selection. CID.

Electrostatic ion beam traps(detection of neutral products)

Use of other types of traps:

„Cone Trap“

Bernard et al.NIM B, 2003Trapping of C60

3+

Inspired by Zajfman & Co.

Page 68: ClusterTrap: A Penning Trap for Cluster Research · ClusterTrap: A Penning Trap for Cluster Research ... H. Stolzenberg et al., PRL 1990. ... CID. 2. selection. CID.

Use of more exotic probes:

Schooß et al. (Kappes)Phil. Trans. Royal Soc.2010

based onJ.H. Parks & Co

Maier-Borst et al., PRA 1999Krückeberg et al., PRL 2000

Trapped ion electron diffraction

Paul trap

Page 69: ClusterTrap: A Penning Trap for Cluster Research · ClusterTrap: A Penning Trap for Cluster Research ... H. Stolzenberg et al., PRL 1990. ... CID. 2. selection. CID.

IR-MPI (infrared multiple photon dissociation) spectroscopy of mass-selected clusters (etc.)

Oomens et al. (von Helden, Meijer) IJMS 2006

IR-FEL at FOM(Nieuwegein)

3D rf trapcoupled toor rather the other way

Page 70: ClusterTrap: A Penning Trap for Cluster Research · ClusterTrap: A Penning Trap for Cluster Research ... H. Stolzenberg et al., PRL 1990. ... CID. 2. selection. CID.

Lau & Co.PRL 101, 2008 PRB 79, 2009

JPhysB 42, 2009PRA 79, 2009

synchrotron radiation

X-ray spectroscopy on size-selected clusters in an ion trap(at BESSY/Berlin)

e-

e-

e-

Auger decay

VSin+

Page 71: ClusterTrap: A Penning Trap for Cluster Research · ClusterTrap: A Penning Trap for Cluster Research ... H. Stolzenberg et al., PRL 1990. ... CID. 2. selection. CID.

A novel concept for the storage of cold ions (20 K) within an FT-ICR spectrometer

100 K Ron Heeren100 K Martin Beyer100 K Evan Williams30 K Christine Joblin16 K FRITZ prototype16 K GAMBIT prototype

Niedner-SchatteburgDPG (AMOP) meeting March 2010

XMCDx-ray absorption

magnetic dichroism

Page 72: ClusterTrap: A Penning Trap for Cluster Research · ClusterTrap: A Penning Trap for Cluster Research ... H. Stolzenberg et al., PRL 1990. ... CID. 2. selection. CID.

Overview

Other traps and applications

ClusterTrapclusters? why? how? what?

Other cluster-storage devices

The EndThanks for your attention !