7/29/2019 Cluster3_Drive2
1/35
SiteID
WBTSNAME
CellID(Revised)
WBTSID(REVISED)
SiteCategory
ActualHeight
Azimuth
MechanicalTilt
ElectricalTilt
Integra
tion
Status
Ra
diation
Status
1010 MUMPAKEEZAMSMCRGF3G 10106 1010 Macro 28 70 2 0 Integrated YES
1010 MUMPAKEEZAMSMCRGF3G 10107 1010 Macro 27 180 2 0 Integrated YES
1010 MUMPAKEEZAMSMCRGF3G 10108 1010 Macro 28 240 2 0 Integrated YES
1023 ZQMUMHTSAHARASMCRGF3G 10236 1023 #N/A #N/A #N/A #N/A #N/A #N/A
1023 ZQMUMHTSAHARASMCRGF3G 10237 1023 #N/A #N/A #N/A #N/A #N/A #N/A
1023 ZQMUMHTSAHARASMCRGF3G 10238 1023 #N/A #N/A #N/A #N/A #N/A #N/A
1025 MUMTURFVIEWSMCRGF3G 10256 1025 Macro 20 20 2 0 Integrated y
1025 MUMTURFVIEWSMCRGF3G 10257 1025 Macro 22 170 2 0 Integrated y
1025 MUMTURFVIEWSMCRGF3G 10258 1025 Macro 24 300 2 0 Integrated y
1123 MUMAPSARACISIARGP3G 11236 1123 Macro 37 90 2 0 Integrated YES
1123 MUMAPSARACISIARGP3G 11237 1123 Macro 37 180 2 0 Integrated YES
1123 MUMAPSARACISIARGP3G 11238 1123 Macro 36 0 2 0 Integrated YES
1123 MUMAPSARACISIARGP3G 11239 1123 Macro 37 270 2 0 Integrated No
1124 ZQMUMTEMPLEBESMCRGF3G 11246 1 124 Macro 23 90 2 0 Integrated YES
1124 ZQMUMTEMPLEBESMCRGF3G 11247 1124 Macro 23 200 2 0 Integrated YES
1124 ZQMUMTEMPLEBESMCRGF3G 11248 1124 Macro 23 340 2 0 Integrated YES
1156 ZQMUMMAZDAQQQSMCRGF3G 11566 1156 #N/A #N/A #N/A #N/A #N/A #N/A
1156 ZQMUMMAZDAQQQSMCRGF3G 11567 1156 #N/A #N/A #N/A #N/A #N/A #N/A
1156 ZQMUMMAZDAQQQSMCRGF3G 11568 1156 #N/A #N/A #N/A #N/A #N/A #N/A
1218 MUMDELSTARQSMCRGF3G 12186 1218 Macro 25 50 1 0 Integrated YES
1218 MUMDELSTARQSMCRGF3G 12187 1218 Macro 25 160 2 0 Integrated YES
1218 MUMDELSTARQSMCRGF3G 12188 1218 Macro 25 340 2 0 Integrated y
1222 MUMPARADISESIARGF3G 12226 1222 Macro 42 40 2 0 Integrated YES
1222 MUMPARADISESIARGF3G 12227 1222 Macro 42 180 2 0 Integrated YES
7/29/2019 Cluster3_Drive2
2/35
1223 MUMGEETANJASMCRGF3G 12236 1223 Macro 33 10 2 0 Integrated YES
1223 MUMGEETANJASMCRGF3G 12237 1223 Macro 31 160 2 0 Integrated YES
1223 MUMGEETANJASMCRGF3G 12238 1223 Macro 33 240 2 0 Integrated YES
1224 ZQMUMMOHANLAHSMCRGF3G 12246 1224 #N/A #N/A #N/A #N/A #N/A #N/A
1224 ZQMUMMOHANLAHSMCRGF3G 12247 1224 #N/A #N/A #N/A #N/A #N/A #N/A
1224 ZQMUMMOHANLAHSMCRGF3G 12248 1224 #N/A #N/A #N/A #N/A #N/A #N/A
1225 MUMVIKASVAISIARGP3G 12256 1225 Macro 27 100 2 0 Integrated YES
1225 MUMVIKASVAISIARGP3G 12257 1225 Macro 25 230 2 0 Integrated YES
1225 MUMVIKASVAISIARGP3G 12258 1225 Macro 27 350 2 0 Integrated YES
1226 MUMSONAWALASMCRGF3G 12266 1226 Macro 22 80 2 0 Integrated YES
1226 MUMSONAWALASMCRGF3G 12267 1226 Macro 22 180 2 0 Integrated YES
1226 MUMSONAWALASMCRGF3G 12268 1226 Macro 22 330 2 0 Integrated YES
1227 ZQMUMSEAGULLASMCRGF3G 12276 1227 #N/A #N/A #N/A #N/A #N/A No
1227 ZQMUMSEAGULLASMCRGF3G 12277 1227 #N/A #N/A #N/A #N/A #N/A No
1229 MUMIMRANTOWSIARGP3G 12296 1229 Macro 28 90 2 0 Integrated No
1229 MUMIMRANTOWSIARGP3G 12297 1229 Macro 28 210 2 0 Integrated No
1229 MUMIMRANTOWSIARGP3G 12298 1229 Macro 28 330 2 0 Integrated No
1264 MUMMEHERABASMCRGF3G 12646 1264 Macro 22 20 2 0 Integrated y
1264 MUMMEHERABASMCRGF3G 12647 1264 Macro 22 120 2 0 Integrated y
1264 MUMMEHERABASMCRGF3G 12648 1264 Macro 22 200 2 0 Integrated y
1283 ZQMUMTARDEOACSMCRGF3G 12836 1283 #N/A #N/A #N/A #N/A #N/A No
1283 ZQMUMTARDEOACSMCRGF3G 12837 1283 #N/A #N/A #N/A #N/A #N/A No
1283 ZQMUMTARDEOACSMCRGF3G 12838 1283 #N/A #N/A #N/A #N/A #N/A No
1304 MUMSHNTINKTSMCRGF3G 13046 1304 Macro 28 10 2 0 Integrated YES
1304 MUMSHNTINKTSMCRGF3G 13047 1304 Macro 28 110 1 0 Integrated YES
1304 MUMSHNTINKTSMCRGF3G 13048 1304 Macro 28 210 2 0 Integrated YES
1304 MUMSHNTINKTSMCRGF3G 13049 1304 Macro 28 280 4 0 Integrated YES
1517 MUMZENITHTISMCRGF3G 15179 1517 Macro 21 280 2 0 Integrated YES
1517 MUMZENITHTISMCRGF3G 15176 1517 Macro 22 60 2 0 Integrated YES
1517 MUMZENITHTISMCRGF3G 15177 1517 Macro 18 160 2 0 Integrated y
1517 MUMZENITHTISMCRGF3G 15178 1517 Macro 16 280 2 0 Integrated y
1526 ZQMUMARIHANTQSIARGF3G 15266 1526 #N/A #N/A #N/A #N/A #N/A No
1526 ZQMUMARIHANTQSIARGF3G 15267 1526 #N/A #N/A #N/A #N/A #N/A No
1526 ZQMUMARIHANTQSIARGF3G 15268 1526 #N/A #N/A #N/A #N/A #N/A No
7/29/2019 Cluster3_Drive2
3/35
1565 MUMBKMHIGHSSMCRGF3G 15656 1565 Macro 27 90 1 0 Integrated y
1565 MUMBKMHIGHSSMCRGF3G 15657 1565 Macro 27 200 2 0 Integrated y
1765 ZQMUMMARATHAMSMCRGF3G 17656 1765 #N/A #N/A #N/A #N/A #N/A #N/A
1765 ZQMUMMARATHAMSMCRGF3G 17657 1765 #N/A #N/A #N/A #N/A #N/A #N/A
1765 ZQMUMMARATHAMSMCRGF3G 17658 1765 #N/A #N/A #N/A #N/A #N/A #N/A
1910 ZQMUMGHASWALASMCRGF3G 19106 1910 #N/A #N/A #N/A #N/A #N/A #N/A
1910 ZQMUMGHASWALASMCRGF3G 19107 1910 #N/A #N/A #N/A #N/A #N/A #N/A1910 ZQMUMGHASWALASMCRGF3G 19108 1910 #N/A #N/A #N/A #N/A #N/A #N/A
1912 MUMGOKULDHASMCRGF3G 19126 1912 Macro 33 140 2 0 Integrated y
1912 MUMGOKULDHASMCRGF3G 19127 1912 Macro 33 200 2 0 Integrated y
1912 MUMGOKULDHASMCRGF3G 19128 1912 Macro 32 340 2 0 Integrated y
2559 MUMJJLTDQQQSMCRGF3G 25596 2559 IBS #N/A #N/A #N/A #N/A Integrated
2559 MUMJJLTDQQQSMCRGF3G 25597 2559 IBS #N/A #N/A #N/A #N/A Integrated
2680 ZQMUMANTLIAQQSMCRGF3G 26806 2680 #N/A #N/A #N/A #N/A #N/A #N/A
2680 ZQMUMANTLIAQQSMCRGF3G 26807 2680 #N/A #N/A #N/A #N/A #N/A #N/A
2680 ZQMUMANTLIAQQSMCRGF3G 26808 2680 #N/A #N/A #N/A #N/A #N/A #N/A2814 ZQMUMDRMBD1QQSMCRGF3G 28146 2814 #N/A #N/A #N/A #N/A #N/A #N/A
2814 ZQMUMDRMBD1QQSMCRGF3G 28147 2814 #N/A #N/A #N/A #N/A #N/A #N/A
3051 ZQMUMJASLOKHOSMCRGF3G 30516 3051 #N/A #N/A #N/A #N/A #N/A #N/A
3051 ZQMUMJASLOKHOSMCRGF3G 30517 3051 #N/A #N/A #N/A #N/A #N/A #N/A
3058 MUMNSCIQQQQSMCRGF3G 30586 3058 IBS #N/A #N/A #N/A #N/A Integrated
3073 ZQMUMATRIAMALSMCRGF3G 30736 3073 #N/A #N/A #N/A #N/A #N/A #N/A
3073 ZQMUMATRIAMALSMCRGF3G 30737 3073 #N/A #N/A #N/A #N/A #N/A #N/A
3114 MUMPOONAMWOSMCRGF3G 31146 3114 IBS #N/A #N/A #N/A #N/A Integrated
3190 ZQMUMSRINIKTASMCRGF3G 31906 3190 #N/A #N/A #N/A #N/A #N/A #N/A
3196 MUMHEERAPANSMCRGF3G 31966 3196 IBS #N/A #N/A #N/A #N/A Integrated
3221 MUMACMARKTQSMCRGF3G 32216 3221 IBS #N/A #N/A #N/A #N/A Integrated
3221 MUMACMARKTQSMCRGF3G 32217 3221 IBS #N/A #N/A #N/A #N/A Integrated
3486 MUMCADBURYHSMCRGF3G 34866 3486 IBS #N/A #N/A #N/A #N/A Integrated
3606 MUMPONMQQQQSMCRGF3G 36066 3606 IBS #N/A #N/A #N/A #N/A Integrated
3769 MUMZENITHHSSMCRGF3G 37696 3769 IBS #N/A #N/A #N/A #N/A Integrated
3785 ZQMUMSRINKTANSMCRGF3G 37856 3785 #N/A #N/A #N/A #N/A #N/A #N/A
4055 MUMKSTURBHVSIARGF3G 40556 4055 Macro 25 10 0 0 Integrated No
4055 MUMKSTURBHVSIARGF3G 40557 4055 Macro 25 150 2 0 Integrated y
4055 MUMKSTURBHVSIARGF3G 40558 4055 Macro 24 280 2 0 Integrated y
4342 MUMHLKALPANSIARGP3G 43426 4342 Macro 25 350 2 0 Integrated y
4342 MUMHLKALPANSIARGP3G 43427 4342 Macro 25 120 2 0 Integrated y
4342 MUMHLKALPANSIARGP3G 43428 4342 Macro 21 250 2 0 Integrated y
4545 MUMRAJDHANQSMCRGF3G 45456 4545 #N/A #N/A #N/A #N/A #N/A #N/A4545 MUMRAJDHANQSMCRGF3G 45457 4545 #N/A #N/A #N/A #N/A #N/A #N/A
4545 MUMRAJDHANQSMCRGF3G 45458 4545 #N/A #N/A #N/A #N/A #N/A #N/A
5056 MUMSUJATAQQSMCRGF3G 50566 5056 Macro 31 20 2 0 Integrated y
5056 MUMSUJATAQQSMCRGF3G 50567 5056 Macro 31 190 2 0 Integrated y
5056 MUMSUJATAQQSMCRGF3G 50568 5056 Macro 27 270 2 0 Integrated y
5057 ZQMUMRAGHAVJISMCRGF3G 50576 5057 #N/A #N/A #N/A #N/A #N/A #N/A
5057 ZQMUMRAGHAVJISMCRGF3G 50577 5057 #N/A #N/A #N/A #N/A #N/A #N/A
7/29/2019 Cluster3_Drive2
4/35
5159 MUMAAKASHCHSMCRGF3G 51596 5159 #N/A #N/A #N/A #N/A #N/A #N/A
5159 MUMAAKASHCHSMCRGF3G 51597 5159 #N/A #N/A #N/A #N/A #N/A #N/A
5364 MUMSASTRIQQSMCRGF3G 53646 5364 Macro 18 40 2 0 Integrated YES
5364 MUMSASTRIQQSMCRGF3G 53647 5364 Macro 18 160 2 0 Integrated YES
5461 ZQMUMVALLARDQSMCRGF3G 54616 5461 #N/A #N/A #N/A #N/A #N/A #N/A
6116 MUMMAHAVIRQSMCRGF3G 61166 6116 Macro 17 50 2 0 Integrated YES
6116 MUMMAHAVIRQSMCRGF3G 61167 6116 Macro 17 170 2 0 Integrated YES
6116 MUMMAHAVIRQSMCRGF3G 61168 6116 Macro 17 270 2 0 Integrated YES
6142 ZQMUMAVISHKARSMCRGF3G 61426 6142 #N/A #N/A #N/A #N/A #N/A #N/A
6142 ZQMUMAVISHKARSMCRGF3G 61427 6142 #N/A #N/A #N/A #N/A #N/A #N/A
6142 ZQMUMAVISHKARSMCRGF3G 61428 6142 #N/A #N/A #N/A #N/A #N/A #N/A
6272 ZQMUMLOVGROFLSMCRGF3G 62726 6272 #N/A #N/A #N/A #N/A #N/A #N/A
6272 ZQMUMLOVGROFLSMCRGF3G 62727 6272 #N/A #N/A #N/A #N/A #N/A #N/A
6495 ZQMUMFPHHAJIOSMCRGF3G 64956 6495 #N/A #N/A #N/A #N/A #N/A #N/A
6495 ZQMUMFPHHAJIOSMCRGF3G 64957 6495 #N/A #N/A #N/A #N/A #N/A #N/A
6495 ZQMUMFPHHAJIOSMCRGF3G 64958 6495 #N/A #N/A #N/A #N/A #N/A #N/A
7/29/2019 Cluster3_Drive2
5/35
Commen
ts
Elec
trica
lTilt
Orien
tation
Changes
Imp
lemen
tation
Type
Fina
lAz
imu
th
Dina
lMec
han
ica
lTilt
Fina
lElec
trica
lTilt
Remove Mechanical Tilt and replace by Electrical tilt 4 Physical 70 0 4
Remove Mechanical Tilt and replace by Electrical tilt. Reorientation Required 2 160 Physical 170 2 2
Remove Mechanical Tilt and replace by Electrical tilt 2 Physical 240 2 2
Antenna height reduction. Remove Mechanical Tilt and replace by Electrical tilt.
CPICH power to be reduced by 2 dB. 3 Physical 20 0 3
Antenna height reduction. Antenna change to 33 deg. CPICH power reduction of 2
dB. 4 Physical 170 2 4
Remove Mechanical Tilt and replace by Electrical tilt 2 Physical 300 0 2
Sector Swap. Antenna Height Reduction required. CPICH power to be reduced by
2 dB. Remove Mechanical Tilt and replace by Electrical tilt 4 Physical 90 2 4
Antenna Height Reduction required. CPICH power to be reduced by 2 dB.
Remove Mechanical Tilt and replace by Electrical tilt 4 Physical 160 2 4
Antenna Height Reduction required. CPICH power to be reduced by 2 dB.
Remove Mechanical Tilt and replace by Electrical tilt 4 Physical 10 2 4
Sector Swap. Antenna Height Reduction required. CPICH power to be reduced by
2 dB. Remove Mechanical Tilt and replace by Electrical tilt 4 Physical 260 2 4
Remove Mechanical Tilt and replace by Electrical tilt.Reorientation Required 3 70 Physical 80 2 1
Sector is blocked.Remove Mechanical Tilt and replace by Electrical
tiltReorientation Required 3 250 Physical 240 2 2
Sector is blocked.Remove Mechanical Tilt and replace by Electrical tilt. CPICH
power to be reduced by 2 dB. 2 Physical 340 2 0
Antenna Height reduction required. Remove Mechanical Tilt and replace by
Electrical tilt. CPICH power to be reduced by 2 dB. Reorientation Required 3 50 Physical 80 1 2
Remove Mechanical Tilt and replace by Electrical tilt. 2 Physical 170 1 2
Remove Mechanical Tilt and replace by Electrical tilt.Reorientation Required 3 330 Physical 320 1 2
Remove Mechanical Tilt and replace by Electrical tilt. 4 Physical 40 3 0
Remove Mechanical Tilt and replace by Electrical tilt. 3 Physical 180 3 0
1st Cut Analysis
7/29/2019 Cluster3_Drive2
6/35
Remove Mechanical Tilt and replace by Electrical tilt. 3 10 Physical 10 0 0
Remove Mechanical Tilt and replace by Electrical tilt.Reorientation Required 3 150 Physical 160 2 2
Remove Mechanical Tilt and replace by Electrical tilt.CPICH power to be reduced
by 2 dB 4 240 Physical 240 0 2
Remove Mechanical Tilt and replace by Electrical tilt. 3 Physical 100 1 3
Remove Mechanical Tilt and replace by Electrical tilt. 3 Physical 230 0 3
Remove Mechanical Tilt and replace by Electrical tilt. CPICH power to be reduced
by 2 dB 2 Physical 350 0 2
Remove Mechanical Tilt and replace by Electrical tilt.Reorientation Required 3 100 Physical 60 0 3
Remove Mechanical Tilt and replace by Electrical tilt. Reorientation Required 4 200 Physical 180 0 4
Remove Mechanical Tilt and replace by Electrical tilt. CPICH power to be reducedby 2 dB 2 Physical 300 0 2
Remove Mechanical Tilt and replace by Electrical tilt.Suspected cross feeder swap.
Reorientation Required 4 0 Physical 0 1 3
Remove Mechanical Tilt and replace by Electrical tilt.Suspected cross feeder swap.
Reorientation Required 4 100 Physical 120 1 3
Remove Mechanical Tilt and replace by Electrical tilt. Suspected cross feeder swap 4 Physical 200 1 3
Remove Mechanical Tilt and replace by Electrical tilt. Reorientation Required 2 0 Physical 0 0 2
Remove Mechanical Tilt and replace by Electrical tilt. 2 Physical 120 2 2
Remove Mechanical Tilt and replace by Electrical tilt. Reorientation Required 2 220 Physical 240 2 2
Remove Mechanical Tilt and replace by Electrical tilt. CPICH power to be reduced
by 2 dB. Reorientation Required 2 300 Physical 280 2 2
Cross Feeder Swap Suspected. Site Audit Required to confirm sector orientation 3 Physical 340 2 3
Cross Feeder Swap Suspected. Remove Mechanical Tilt and replace by Electrical
tilt. CPICH power to be reduced by 2 dB. Site Audit Required to confirm sector
orientation 2 Physical 80 5 2
Cross Feeder Swap Suspected. Remove Mechanical Tilt and replace by Electrical
tilt. Site Audit Required to confirm sector orientation 3 Physical 160 0 3
Cross Feeder Swap Suspected. Site Audit Required to confirm sector orientation 3 Physical 280 2 3
7/29/2019 Cluster3_Drive2
7/35
Remove Mechanical Tilt and replace by Electrical tilt. CPICH power to be reduced
by 2 dB. Reorientation Required 2 40 Physical 80 1 2
Remove Mechanical Tilt and replace by Electrical tilt. CPICH power to be reduced
by 2 dB 2 Physical 210 1 1
Remove Mechanical Tilt and replace by Electrical tilt. CPICH power to be reduced
by 2 dB. Reorientation Required 2 30 Physical 120 1 2
Remove Mechanical Tilt and replace by Electrical tilt. CPICH power to be reduced
by 2 dB. Reorientation Required 2 30 Physical 220 0 2
Remove Mechanical Tilt and replace by Electrical tilt. CPICH power to be reduced
by 2 dB. Reorientation Required 2 30 Physical 340 1 2
Reorientation Change required. Remove Mechanical tilt and replace by electrical
tilt. CPICH power to be reduced by 2 dB 90 Physical 80 0 2
Reorientation Change required. Remove Mechanical tilt and replace by electrical
tilt. CPICH power to be reduced by 2 dB 190 Physical 190 2 0
Reorientation Change required. Remove Mechanical tilt and replace by electrical
tilt.CPICH power to be reduced by 2 dB 280 Physical 280 2 0
Remove Mechanical Tilt and replace by Electrical tilt. CPICH power to be reduced
by 2 dB 3 Physical 350 0 3
Remove Mechanical Tilt and replace by Electrical tilt. CPICH power to be reduced
by 2 dB 3 Physical 120 0 3
Remove Mechanical Tilt and replace by Electrical tilt. Reorientation Required 3 230 Physical 250 2 Not visible
Remove Mechanical Tilt and replace by Electrical tilt. 3 Physical 20 0 3
Remove Mechanical Tilt and replace by Electrical tilt. 3 Physical 170 0 3
Remove Mechanical Tilt and replace by Electrical tilt. 3 Physical 270 0 3
7/29/2019 Cluster3_Drive2
8/35
Remove Mechanical Tilt and replace by Electrical tilt. 3 Physical 30 1 2
Remove Mechanical Tilt and replace by Electrical tilt. 2 Physical 110 2 2
Remove Mechanical Tilt and replace by Electrical tilt. 3 Physical 50 2 0
Remove Mechanical Tilt and replace by Electrical tilt. 3 Physical 170 2 0
Remove Mechanical Tilt and replace by Electrical tilt. 3 Physical 270 2 0
7/29/2019 Cluster3_Drive2
9/35
Remarks
Integra
tion
Status
Ra
diation
Status
ET Changed YES YES
6 port antenna shared with 2G, MT cannot be changed YES YES
6 port antenna shared with 2G, MT cannot be changed YES YES
YES YES
YES YES
YES YES
MT & ET Changed YES no
ET Changed YES no
MT & ET Changed YES no
Swap removed YES YES
Swap removed YES YES
Swap removed YES YES
Swap removed YES YES
4 Port antenna shared with 2G YES YES
6 port antenna shared with 2G, MT cannot be changed YES YES
4 Port antenna shared with 2G YES YES
NO
NO
NO
Cannot change Azimuth & MT, antenna shared with 2G YES YES
Cannot change MT, antenna shared with 2G YES YES
Cannot change Azimuth & MT, antenna shared with 2G YES No
ET Cannot be changed, High gain antenna installed YES YES
ET Cannot be changed, High gain antenna installed YES YES
1st Cut Implementation
7/29/2019 Cluster3_Drive2
10/35
MT & ET Changed YES YES
6 Port Wallmount antenna, azimuth, MT & ET not changed YES YES
ET Changed, High gain antenna installed YES YES
NO
NO
NO
ET changed, MT Cannot be changed, Antenna shared with 2G YES YES
MT & ET Changed YES YES
MT & ET Changed YES YES
Actual Azimuth Captured, ET Changed YES YES
ET Changed YES YES
Actual Azimuth Captured, ET Changed YES YES
NO
NO
YES YES
YES No
YES YES
6 port antenna shared with 2G, MT cannot be changed. Project was working on this site for
VSWR clearance, no feeder connected when attempted, Swap to be checked YES
Azimuth & MT cannot be changed, 6 port antenna. Project was working on this site for VSWR
clearance, no feeder connected when attempted, Swap to be checked YES No
6 port antenna shared with 2G, MT cannot be changed. Project was working on this site for
VSWR clearance, no feeder connected when attempted, Swap to be checked YES No
NO
NO
NO
ET & MT changed YES YES
ET changed YES YES
6 Port antenna, azimuth & MT cannot be changed YES YES
4 Port antenna, azimuth & MT cannot be changed YES YES
MT & ET Changed YES YES
No MT change can be done due to Hawk problem, ET Changed YES Yes
MT & ET Changed YES Yes
MT & ET Changed YES Yes
NO
NO
NO
7/29/2019 Cluster3_Drive2
11/35
6 port antenna Wallmount shared with 2G, azimuth & MT cannot be changed YES No
4 Port antenna, azimuth & MT cannot be changed, ET-1 changed YES No
NO
NO
NO
NO
NO
NO
6 Port Wallmount antenna, azimuth, MT & ET not changed YES YES
6 Port Wallmount antenna, azimuth, MT & ET not changed YES YES
6 Port Wallmount antenna, azimuth, MT & ET not changed YES YES
YES
YES
NO
NO
NONO
NO
NO
NO
YES
NO
NO
YES
NO
YES
YES
YES
YES
YES
YES
NO
ET Changed, Azimuth cannot be changed, Antenna shared with 2G YES YES
Azimuth changed YES YES
Azimuth changed YES YES
ET Changed YES YES
ET Changed YES YES
Wallmount antenna, ET not changed YES YES
NONO
NO
MT & ET Changed YES YES
MT & ET Changed YES YES
MT & ET Changed YES YES
NO
NO
7/29/2019 Cluster3_Drive2
12/35
NO
NO
6 port antenna, MT cannot be changed YES YES
6 port antenna, MT cannot be changed YES YES
NO
Wallmount antenna, MT & ET cannot be changed YES YES
Wallmount antenna, MT & ET cannot be changed YES YES
Wallmount antenna, MT & ET cannot be changed YES YES
NO
NO
NO
NO
NO
YES YES
YES YES
YES YES
7/29/2019 Cluster3_Drive2
13/35
Commen
ts
Fina
lElec
trica
lTilt
Orien
tation
Changes
Az
imu
th
Mec
han
ica
lTilt
Elec
trica
lTilt
OK
Add Electrical Tilt 2 Deg 4 170 2 4
Add Electrical Tilt 2 Deg 4 280 2 4
Sector Swap Observed. Remove Mechanical tilt &
add Electrical tilt. 3 60 Not visible
Sector Swap Observed. Remove Mechanical tilt &
add Electrical tilt. 4 180 Not visible
Sector Swap Observed. Remove Mechanical tilt &
add Electrical tilt. 4 350 0 2
Not Radiating in Drive 2
Not Radiating in Drive 2
Not Radiating in Drive 2
Antenna Height Redcution is a must as sector is
polluter to other sites. Else Reduce CPICH power
by 3dB. Remove Mechanical Tilt Add Electrical Tilt
2 Deg 6 6
Antenna Height Redcution is a must as sector is
polluter to other sites. Else Reduce CPICH power
by 3dB. Remove Mechanical Tilt Add Electrical Tilt
2 Deg 6 6
Antenna Height Redcution is a must as sector is
polluter to other sites. Else Reduce CPICH power
by 3dB. Remove Mechanical Tilt Add Electrical Tilt
2 Deg 6 6Antenna Height Redcution is a must as sector is
polluter to other sites. Else Reduce CPICH power
by 3dB. Remove Mechanical Tilt Add Electrical Tilt
2 Deg 6 6
Add Electrical Tilt 4 70 60 2 4
Sector is blocked. Reorientation is required 250 240 3 Not visible
Sector is blocked. Add Electircal Tilt 2 350 3 2
Antenna Height reduction required. CPICH power
to be reduced by 2 dB. Reorientation Required 50 50 1 4
Add Electrical tilt 4 160 2 2
Not Radiating in Drive 2. Alarm on sector (Radio
resources switched off) 330 2
Antenna Height reduction required. CPICH power
to be reduced by 3 dB. 30 2
Antenna Height reduction required. CPICH power
to be reduced by 3 dB. 190 2
2nd Analysis 2nd Implementatio
7/29/2019 Cluster3_Drive2
14/35
Antenna Height reduction required. CPICH power
to be reduced by 3 dB. Add Electrical tilt 2 deg 5 0 0 5
Antenna Height reduction required. CPICH power
to be reduced by 3 dB. Add Electrical tilt 2 deg 5 160 0 2
Antenna Height reduction required. CPICH power
to be reduced by 3 dB. Add Electrical tilt 2 deg 6 240 0 0
OK 70 0 4
Add Electrical Tilt 2 Deg 5 240 0 5
Antenna Height Reduction required. Else CPICH
power to be reduced by 3 dB. Add Electrical tilit
of 3 deg. 5 340 0 5
Add Electrical tilt of 2deg. Reorient Sector 5 100 100 1 4
Antenna Height Reduction Required. Add
Electrical tilt of 2deg. Reorient Sector 6 200 190 1 4
Add Electrical Tilt of 3 deg. 5 320 2 4
Add Electrical Tilt 3 90 3 Not visible
Increase CPICH Power by 3dB. Remove
Mechanical Tilt & add electrical tilt 2
Add Electrical Tilt 3 330 1 Not visible
Not Radiating in Drive 2. Alarm on sector
Not Radiating in Drive 2. Alarm on sector (Radio
resources switched off)
Not Radiating in Drive 2. Alarm on sector (Radio
resources switched off)
Reduce Antenna Height. Add Electrical tilt of
3deg. Reorient Sector 4 0 0 0 4
OK
Add Electrical tilt 2 2 4
Reduce Antenna height. Else CPICH power to be
reduced by 2 dB. Reorientation Required 300 280 2 4
Remove Mechanical Tilt and replace by Electrical
tilt. 6 350 0 6
Remove Mechanical Tilt and replace by Electrical
tilt. 4 90 2 4
Reorient Sector. Add Electrical Tilt 4 180 180 0 4
Reorient Sector. Add Electrical Tilt 4 260 270 0 4
7/29/2019 Cluster3_Drive2
15/35
Antenna Height Reduction. CPICH power to be
reduced by 2 dB. Add Electrical tilt 3 50 1 2
Antenna Height Reduction. CPICH power to be
reduced by 2 dB. Add Electrical tilt 3 120 0 3
Add Electrical Tilt. Reorient Sectors as suggested 2 30 140 5 4
Add Electrical Tilt. Reorient Sectors as suggested 2 30 220 2 4
Add Electrical Tilt. Reorient Sectors as suggested 2 30 340 4 2
Add Electrical Tilt 4 70 1 4
Remove Mechanical Tilt and replace by Electrical
tilt. 5 150 0 5
Remove Mechanical Tilt and replace by Electrical
tilt. 5 330 0 5
Add Electrical Tilt 5 0 0 5
Add Electrical Tilt 5 90 0 5
Add Electrical Tilt. Reorient Sectors as suggested 2 230 240 0 Not visible
Reduce Antenna height. Else CPICH power to be
reduced by 2 dB. Add Electrical Tilt by 2. 5 20 2 5
Reduce Antenna Height. Add Electrical tilt of 2 5 170 2 5
Reduce Antenna height. Add Electrical Tilt by 2. 5 260 2 5
7/29/2019 Cluster3_Drive2
16/35
OK
OK
OK
Remove Mechanical Tilt and replace by Electrical
tilt. 3 170 2 0
Remove Mechanical Tilt and replace by Electrical
tilt. 3 270 2 0
Suspected Sector Swap. Remove Mechanical tilt
and add Electrical tilt 3 10 4 3
Suspected Sector Swap. Remove Mechanical tilt
and add Electrical tilt 3 190 0 3
Suspected Sector Swap. Remove Mechanical tilt
and add Electrical tilt 3 350 0 3
7/29/2019 Cluster3_Drive2
17/35
remarks
6 PORT antenna shared with
2G
6 PORT antenna shared with
2G
6 PORT antenna shared with
2G
6 PORT antenna shared with
2G
6 PORT wallmount antenna
shared with 2G
OTHER TEAM WOKING FOR
PURPOSE OF GSM HEIGHT &
6 PORT ANTENNA
OTHER TEAM WOKING FOR
PURPOSE OF GSM HEIGHT &
6 PORT ANTENNA
2G TEAM WORKING FOR
PURPOSE OF HEIGHT
INCREASE, 6 PORT ANTENNA
2G TEAM WORKING FOR
PURPOSE OF HEIGHT
INCREASE, 6 PORT ANTENNA
6 Port wallmount antenna
PARAPET MOUNT, ET not
possible to change
PARAPET MOUNT
HIGH GAIN ANTENNA SO ET
CHANGE POSSIBLE
HIGH GAIN ANTENNA SO ET
CHANGE POSSIBLE
n
7/29/2019 Cluster3_Drive2
18/35
6 Port wallmount antenna
HIGH GAIN ANTENNA SO ET
CHANGE POSSIBLE
4 Port antenna shared with
2G
AZIMUTH CHANGED
Antenna not accessible as
footsteps are broken
wallmount
Antenna Not installed
wallmount
4 Port antenna shared with
2G, Azimuth cannot be
changed
7/29/2019 Cluster3_Drive2
19/35
6 Port wallmount antenna,
ET not changed
6 PORT antenna shared with
2G
6 PORT antenna shared with
2G
6 PORT Wallmount antenna
shared with 2G, Azimuth &
MT cannot be changed
6 PORT antenna shared with
2G
ET NOT POSSIBLE DUE TO
WALLMOUNT
7/29/2019 Cluster3_Drive2
20/35
Wallmount antenna, MT &
ET cannot be changed
Wallmount antenna, MT &
ET cannot be changed
4 PORT antenna shared with
2G
7/29/2019 Cluster3_Drive2
21/35
Voice/video call statistics
MO call attempt 335
MO call attempt failure 5
MO call connected 330 330
MO call disconnected 328 328
MO call dropped 2 1
MT call attempt 0
MT call attempt failure 0
MT call connected 0
MT call disconnected 0MT call dropped 0
ETSI service accessibility 98.51%
ETSI call completion rate 99.39% 99.70%
Event ID Event Event# Measurement Time System
CAD Call dropped 1 11Mar02 043010.1 3/2/11 4:33 AM UMTS FDD
CAD Call dropped 1 11Mar02 045136.1 3/2/11 4:53 AM UMTS FDD
Event ID Event Event# Measurement Time System
CAF Call attempt failure 1 11Mar02 070649.1 3/2/11 7:43 AM UMTS FDD
CAF Call attempt failure 1 11Mar02 094727.1 3/2/11 9:58 AM UMTS FDD
CAF Call attempt failure 1 11Mar02 121824.1 3/2/11 12:27 PM UMTS FDD
CAF Call attempt failure 2 11Mar02 121824.1 3/2/11 12:28 PM UMTS FDD
CAF Call attempt failure 1 11Mar02 130523.1 3/2/11 1:08 PM UMTS FDD
7/29/2019 Cluster3_Drive2
22/35
Serving band CS disc. status Call type Direction CS disc. cause CS call dur.
2100 Dropped call (i.e. network release) Voice call Mobile originated 31 00:12.6
2100 Dropped call (i.e. network release) Voice call Mobile originated 31 00:42.3
Serving band CS fail. status Call type CS fail. cause
2100 RRC connection failed Voice call
2100 RRC connection failed Voice call
2100 RRC connection failed Voice call 16
2100 Timeout before connection Voice call 16
2100 Call was released before connection Voice call
7/29/2019 Cluster3_Drive2
23/35
Call duration (s) Serving Sector RSCP EcNo BLER Tx PWR UL Intf Diagnosis & Recommendations
12 1203 & 5585 -80 -7.6 0 -15 -105
Site 1203 - Transmission & DAC Alarms
on site & 5585 - Cell Faulty (VSWR),
Cell out of use (Resource status
indication, cell disabled) & Cell
Notification Alarm (Radio resources
switched off)
42 1268 & 5159 -92 -11.5 0 -4 -105
1268 & 5159 - Cell Faulty (VSWR) &Cell Notification Alarm (Radio
resources switched off)
CS fail. time Serving Sector RSCP EcNo BLER RACH Tx PWR UL Intf Diagnosis & Recommendations
15 10108 -108 -21.5 23 -105
Poor Dominance Area. CPICH power
increase by 3dB for site 61168.
15 No Coverage.
15 No Coverage.
15 No Coverage.
0 Non Genuine Call Failure.
7/29/2019 Cluster3_Drive2
24/35
Voice/video call statistics
MO call attempt 331
MO call attempt failure 7
MO call connected 324 324
MO call disconnected 322 322
MO call dropped 2 1
MT call attempt 0
MT call attempt failure 0
MT call connected 0MT call disconnected 0
MT call dropped 0
ETSI service accessibility 97.89%
ETSI call completion rate 99.38% 99.69%
Event ID Event Event# Measurement Time System Serving band
CAD Call dropped 1 11Mar02 043010.3 3/2/11 4:33 AM UMTS FDD 2100
CAD Call dropped 1 11Mar02 045136.3 3/2/11 4:53 AM UMTS FDD 2100
Event ID Event Event# Measurement Time System Serving band
CAF Call attempt failure 1 11Mar02 045136.3 3/2/11 4:57 AM UMTS FDD 2100
CAF Call attempt failure 2 11Mar02 045136.3 3/2/11 4:57 AM UMTS FDD 2100
CAF Call attempt failure 3 11Mar02 045136.3 3/2/11 5:26 AM UMTS FDD 2100
CAF Call attempt failure 1 11Mar02 060907.3 3/2/11 6:55 AM UMTS FDD 2100
CAF Call attempt failure 1 11Mar02 084854.3 3/2/11 8:49 AM UMTS FDD 2100
CAF Call attempt failure 1 11Mar02 092524.3 3/2/11 9:45 AM UMTS FDD 2100
CAF Call attempt failure 1 11Mar02 094727.3 3/2/11 9:58 AM UMTS FDD 2100
7/29/2019 Cluster3_Drive2
25/35
CS disc. status Call type Direction CS disc. cause CS call dur. Call duration (s)
Dropped call (i.e. network release) Video call Mobile originated 31 00:14.3 14
Dropped call (i.e. network release) Video call Mobile originated 31 00:45.7 45
CS fail. status Call type CS fail. cause CS fail. time
RRC connection failed Video call 30
RRC connection failed Video call 30
RRC connection failed Video call 30
RRC connection failed Video call 30
Timeout before connection Video call 30
RRC connection failed Video call 4
RRC connection failed Video call 30
7/29/2019 Cluster3_Drive2
26/35
Serving Sector RSCP EcNo BLER Tx PWR UL Intf Diagnosis & Recommendations
1203 & 5585 -80 -7.6 0 -15 -105
Site 1203 - Transmission & DAC Alarms
on site & 5585 - Cell Faulty (VSWR),
Cell out of use (Resource status
indication, cell disabled) & Cell
Notification Alarm (Radio resourcesswitched off)
1268 & 5159 -92 -11.5 0 -4 -105
1268 & 5159 - Cell Faulty (VSWR) &
Cell Notification Alarm (Radio
resources switched off)
Serving Sector RSCP EcNo BLER Tx PWR UL Intf Diagnosis & Recommendations
12687 -92 -24.8 -106
1268 - Cell Faulty (VSWR) & Cell
Notification Alarm (Radio resources
switched off). Missing Neighbour issue.
Sync Issue
19368 -94 -23.1 14 -106 Missing Neighbour issue. Sync Issue
12686 -72 -3.4 -105
1268 - Cell Faulty (VSWR) & Cell
Notification Alarm (Radio resources
switched off). Missing Neighbour issue.
Sync Issue
10136 -92 -24.9 9 -105
Cell operation degraded alarm (RF
module failure)
Missing Neighbour issue. IBS with SC
425 is radiating outdoor. Neighbour to
be added with 11236, 13138 & 43436
11246 -96 -15.9 10 -106
Non Genuine Call Failure Attempt as
UE is Sends CM Service Abort Message
in Uplink after RRC Connection setup
message.
1012 -96 -10.5 -106
Unwanted Server covering area due to
non Coverage. Cell be to be optimised.
7/29/2019 Cluster3_Drive2
27/35
Voice/video call statistics
MO call attempt 86
MO call attempt failure 11
MO call connected 75
MO call disconnected 64
MO call dropped 11
MT call attempt 0
MT call attempt failure 0
MT call connected 0
MT call disconnected 0MT call dropped 0
ETSI service accessibility 87.21%
ETSI call completion rate 85.33%
Event ID Event Event# Measurement Time System Serving band
CAD Call dropped 1 11Mar02 043010.2 30:12.0 GSM 1800
CAD Call dropped 1 11Mar02 045136.2 3/2/2011 4:56 UMTS FDD 2100
CAD Call dropped 1 11Mar02 060907.2 34:40.3 GSM 1800
CAD Call dropped 1 11Mar02 070649.2 17:47.4 GSM 1800
CAD Call dropped 1 11Mar02 075429.2 10:33.8 GSM 1800
CAD Call dropped 1 11Mar02 101819.2 20:41.3 GSM 1800
CAD Call dropped 1 11Mar02 102937.2 35:00.6 GSM 1800
CAD Call dropped 1 11Mar02 120550.2 07:42.6 GSM 1800
CAD Call dropped 1 11Mar02 121824.2 3/2/2011 12:27 UMTS FDD 2100
CAD Call dropped 2 11Mar02 121824.2 3/2/2011 12:29 UMTS FDD 2100
CAD Call dropped 1 11Mar02 131344.2 3/2/2011 13:28 UMTS FDD 2100
7/29/2019 Cluster3_Drive2
28/35
CS disc. status Call type Direction CS disc. cause CS call dur. Call duration (s)
Dropped call (i.e. network release) Voice call Mobile originated 31 00:01.5 1
Dropped call (i.e. network release) Voice call Mobile originated 05:01.6 301
Dropped call (i.e. network release) Voice call Mobile originated 02:03.8 123
Dropped call (i.e. network release) Voice call Mobile originated 01:25.3 85
Dropped call (i.e. network release) Voice call Mobile originated 02:50.6 170
Dropped call (i.e. network release) Voice call Mobile originated 02:20.8 140
Dropped call (i.e. network release) Voice call Mobile originated 05:20.1 320
Dropped call (i.e. network release) Voice call Mobile originated 01:51.0 110
Dropped call (i.e. network release) Voice call Mobile originated 09:18.5 558
Dropped call (i.e. network release) Voice call Mobile originated 01:15.6 75
Dropped call (i.e. network release) Voice call Mobile originated 04:14.4 254
7/29/2019 Cluster3_Drive2
29/35
Serving Sector RSCP EcNo BLER Tx PWR UL Intf Diagnosis & Recommendations
Drop on GSM
12298 -84 -18.8 4.5 -5 -106 Missing Neighbour Issue.
Drop on GSM
Drop on GSM
Drop on GSM
Drop on GSM
Drop on GSM
Drop on GSM
15179 -108 -18.8 38.3 4 -105
Poor Dominance Coverage Area. Sector 19126 to be
reoriented as recommended to 30 deg to improve
coverage.
62458 -118 -23.2 22.4 19 -105
Poor Dominance Coverage Area. Sector 19126 to be
reoriented as recommended to 30 deg to improve
coverage. Missing Neighbour issue.
10268 -108 -21.3 7.3 14 -105
Unwanted Server providing coverage as Site 1025 was
down.
7/29/2019 Cluster3_Drive2
30/35
Attach statistics
Attach attempt 24
Attach failure 0
Attach success 24
Attach success rate 100.00%
PDP context statistics
PDP context activation attempt 29
PDP context activation failure 2
PDP context activation success 27 27PDP context deactivation 25 27
PDP context dropped 2
PDP context activation success rate 93.10%
PDP context cut-off rate 7.41%
Data transfer statistics
Data server connection attempt 0
Data server connection attempt failure 0
Data server connect 0
Data server disconnect 0
Data server connection dropped 0
Data server connection success rate 0.00%
Data server connection cut-off rate 0.00%
File transfer statistics
File transfer request 0
File transfer complete 0
File transfer dropped 0
File transfer success rate 0.00%
Event ID Event Event# Measurement
PAD PDP context dropped 1 11Mar02 075429.4
PAD PDP context dropped 1 11Mar02 133343.4
Event ID Event Event# Measurement
PAF PDP context activation failure 1 11Mar02 045136.4
PAF PDP context activation failure 2 11Mar02 045136.4
7/29/2019 Cluster3_Drive2
31/35
Time System Serving band Status Deact. time Duration
3/2/11 8:29 AM UMTS FDD 2100 Network deactivation (SM cause) 0 2100
3/2/11 1:52 PM UMTS FDD 2100 Network deactivation (SM cause) 0 1131
Time System Serving band Status Fail time
3/2/11 5:26 AM UMTS FDD 2100 Mobile reject (SM cause) 5
3/2/11 5:27 AM UMTS FDD 2100 Timeout 8
7/29/2019 Cluster3_Drive2
32/35
Deact. cause Serving Sector RSCP EcNo BLER Tx PWR UL Intf
Regular deactivation 12268 -56 -3.9 0 -37 -105
Regular deactivation 50566 -110 -14.7 0 21 -105
Deact. cause Serving Sector RSCP EcNo BLER Tx PWR UL Intf
Regular deactivation 19367 -94 -17.1 68.1 1 -106
13047 -90 -8.4
7/29/2019 Cluster3_Drive2
33/35
Diagnosis & Recommendations
No Uplink L3 Message hence network has released
resource.
Drop due to Coverage. Increase CPICH power of
50566, 12257 & 12186
Diagnosis & Recommendations
Missing Neighbour issue. Unwanted Server to be
downtilted.
Non Genuine Call Failure due to cell update.
7/29/2019 Cluster3_Drive2
34/35
Source Target Remark
19367 12686 Add
19367 12687 Add
12686 19367 Add12687 19367 Add
12296 19738 Add
12297 19738 Add
19738 12296 Add
19738 12297 Add
19736 12296 Add
19736 12297 Add
12296 19736 Add
12297 19736 Add
12687 19736 Add
12687 19738 Add
19736 12687 Add
19738 12687 Add
7/29/2019 Cluster3_Drive2
35/35
1026 Sector Swap Suspected
6245 Sector Swap Suspected
19736 Downtilt antenna by 2 deg (Electrical)
50607 Downtilt antenna by 2 deg (Electrical)
12037 Downtilt antenna by 2 deg (Electrical)
42088 Downtilt antenna by 2 deg (Electrical)
10126 Downtilt antenna by 2 deg (Electrical)