Top Banner
Closed Circuit Fluid Cooler
12

Closed Circuit Fluid Cooler - HTS · Induced draft counterflow design. CTI certified in accordance with standard STD-201. Long life construction. 36 different models. ... CLOSED CIRCUIT

Apr 23, 2018

Download

Documents

hoàng_Điệp
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Closed Circuit Fluid Cooler - HTS · Induced draft counterflow design. CTI certified in accordance with standard STD-201. Long life construction. 36 different models. ... CLOSED CIRCUIT

Closed Circuit Fluid Cooler

Page 2: Closed Circuit Fluid Cooler - HTS · Induced draft counterflow design. CTI certified in accordance with standard STD-201. Long life construction. 36 different models. ... CLOSED CIRCUIT

THERMAL PERFORMANCE CERTIFIED BY THE COOLING TECHNOLOGY INSTITUTE

REYMSA´s complete line of Closed Circuit Fluid Coolers are certified by the CTI in accordance with Standard STD-201.

Self contained heat transfer equipment.

Induced draft counterflow design.

CTI certified in accordance with standard STD-201.

Long life construction.

36 different models.

Nominal Capacity: from 80 to 1,035 GPM @ Standard conditions: 95ºF / 85ºF / 78ºF.

Easy access for maintenance.

Easy and economical assembly and installation.

All Non-Corrosive construction materials.

FEATURES:

Leader in “ All-Fiberglass ” Cooling Towers

REYMSA´s success is the result of 35 years of experience in Cooling Towers. We have been putting ideas into action by researching and developing the latest technologies; therefore, we are proud to offer our Closed Circuit Fluid Coolers.

Sound Deflectors.

Access Ladders.

Handrails (Stainless or Galvanized steel).

Vibration Cut off Switches.

Basin Heaters.

Electric Water Level Control.

Non-Skid Catwalk (Stainless or Galvanized steel).

Equalizer Connection for Multiple Tower Installations.

Filtration System: RFS SERIES.

Tower casing construction with flame retardant resin according to the ASTM-E84 Standard.

OPTIONAL EQUIPMENT

Basin Heater SystemElectric Water Level Control

Durable and heavy duty construction.

Gel-coat with UV inhibitors provides superior protection from harsh environments, weather, and aggressive chemical treatment.

Light weight.

Thermally stable composition.

Corrosion resistant.

Minimal maintenance.

BENEFITS

FRP (FIBERGLASS REINFORCED POLYESTER)CASING AND STRUCTURE

REYMSA uses the best fan on the market, using cast

aluminum hubs and adjustable pitch air foil blades

made with glass reinforced polyamide.

Blades material is able to resist high vibration levels.

Ambient operating air temperatures may fluctuate

from - 50ºF to 250ºF.

PAG (GLASS REINFORCED POLYAMIDE)AXIAL FANS

With a superior motor provides the lowest possible

maintenance cost and the most reliable equipment.

Virtually maintenance free: NO belts to adjust and NO

gear boxes to lubricate.

Low speed, NEMA frame, TEFC, Premium Efficiency,

Severe duty, Marine duty, Inverted duty rated fan motors.

All our tower models feature motors that exceed the

Cooling Tower duty motor characteristics.

DIRECT DRIVE SYSTEM

Corrosion resistant Glass ReinforcedPolyamide fan blades

Direct Drive System

REYMSA COOLING TOWERS, INC. REYMSA COOLING TOWERS, INC.

Page 3: Closed Circuit Fluid Cooler - HTS · Induced draft counterflow design. CTI certified in accordance with standard STD-201. Long life construction. 36 different models. ... CLOSED CIRCUIT

THERMAL PERFORMANCE CERTIFIED BY THE COOLING TECHNOLOGY INSTITUTE

REYMSA´s complete line of Closed Circuit Fluid Coolers are certified by the CTI in accordance with Standard STD-201.

Self contained heat transfer equipment.

Induced draft counterflow design.

CTI certified in accordance with standard STD-201.

Long life construction.

36 different models.

Nominal Capacity: from 80 to 1,035 GPM @ Standard conditions: 95ºF / 85ºF / 78ºF.

Easy access for maintenance.

Easy and economical assembly and installation.

All Non-Corrosive construction materials.

FEATURES:

Leader in “ All-Fiberglass ” Cooling Towers

REYMSA´s success is the result of 35 years of experience in Cooling Towers. We have been putting ideas into action by researching and developing the latest technologies; therefore, we are proud to offer our Closed Circuit Fluid Coolers.

Sound Deflectors.

Access Ladders.

Handrails (Stainless or Galvanized steel).

Vibration Cut off Switches.

Basin Heaters.

Electric Water Level Control.

Non-Skid Catwalk (Stainless or Galvanized steel).

Equalizer Connection for Multiple Tower Installations.

Filtration System: RFS SERIES.

Tower casing construction with flame retardant resin according to the ASTM-E84 Standard.

OPTIONAL EQUIPMENT

Basin Heater SystemElectric Water Level Control

Durable and heavy duty construction.

Gel-coat with UV inhibitors provides superior protection from harsh environments, weather, and aggressive chemical treatment.

Light weight.

Thermally stable composition.

Corrosion resistant.

Minimal maintenance.

BENEFITS

FRP (FIBERGLASS REINFORCED POLYESTER)CASING AND STRUCTURE

REYMSA uses the best fan on the market, using cast

aluminum hubs and adjustable pitch air foil blades

made with glass reinforced polyamide.

Blades material is able to resist high vibration levels.

Ambient operating air temperatures may fluctuate

from - 50ºF to 250ºF.

PAG (GLASS REINFORCED POLYAMIDE)AXIAL FANS

With a superior motor provides the lowest possible

maintenance cost and the most reliable equipment.

Virtually maintenance free: NO belts to adjust and NO

gear boxes to lubricate.

Low speed, NEMA frame, TEFC, Premium Efficiency,

Severe duty, Marine duty, Inverted duty rated fan motors.

All our tower models feature motors that exceed the

Cooling Tower duty motor characteristics.

DIRECT DRIVE SYSTEM

Corrosion resistant Glass ReinforcedPolyamide fan blades

Direct Drive System

REYMSA COOLING TOWERS, INC. REYMSA COOLING TOWERS, INC.

Page 4: Closed Circuit Fluid Cooler - HTS · Induced draft counterflow design. CTI certified in accordance with standard STD-201. Long life construction. 36 different models. ... CLOSED CIRCUIT

BENEFITS

Direct-drive, with axial, sickle shaped type, adjustable-pitch fan blades.

Fabricated of corrosion resistant glass reinforced polyamide.

Operation temperature range : -50°F to 250°F.

Low noise emission.

High performance at lower speeds.

High strength due to its large cord.

The vertical inline recirculating pump is designed for optimum performance, easy installation and simplified maintenance.

The close-coupled design results in improved alignment and increased seal life. No isolation pads required.

OPTIONAL LOW NOISE FAN

RECIRCULATING PUMP

Recirculating Pump

Low Noise Fan

Copper is easy to work with, and has excellent thermal conductivity, corrosion resistance and durability.

Stainless steel casing.

Wide diagonal spacing for easy cleaning.

Type L copper.

Designed to block direct sunlight to the water, to minimize algae growth, reduce splash out and noise.

Fabricated from rigid, corrugated UV protected Polyvinyl Chloride (PVC); is easy removable to provide access for cleaning. Resistant to rot, fungi, bacteria and organic/inorganic acids and alkalis.

Meets CTI STD-136.

Flame spread rating is less than 20 according to ASTM E84, and self-extinguishing in less than 5 seconds according to ASTM D635.

COPPER COILS

AIR INLET LOUVERS

Durable, corrosion resistant copper coils.

Air Inlet Louvers

Manufactured of Polyvinyl Chloride (PVC); resistant to rot,

fungi, bacteria and organic/inorganic acids and alkalis

commonly found in cooling towers.

Meets CTI STD-136.

Fill media modules flame spread rating is less than 20

conforming to ASTM E84, and self-extinguishing in less

than 5 seconds conforming to ASTM D635.

Every tower is assembled and tested at the factory prior to shipment.

REYMSA has a deep commitment with customer satisfaction to build long term relationships.

FILM FILL MEDIA

Direct Drive System

Film Fill Media

All interior distribution piping is fabricated using standard PVC.

Water is evenly distributed over the fill media by removable ABS spray nozzles.

HOT WATER DISTRIBUTION SYSTEM

REYMSA COOLING TOWERS, INC. REYMSA COOLING TOWERS, INC.

BENEFITS

Page 5: Closed Circuit Fluid Cooler - HTS · Induced draft counterflow design. CTI certified in accordance with standard STD-201. Long life construction. 36 different models. ... CLOSED CIRCUIT

BENEFITS

Direct-drive, with axial, sickle shaped type, adjustable-pitch fan blades.

Fabricated of corrosion resistant glass reinforced polyamide.

Operation temperature range : -50°F to 250°F.

Low noise emission.

High performance at lower speeds.

High strength due to its large cord.

The vertical inline recirculating pump is designed for optimum performance, easy installation and simplified maintenance.

The close-coupled design results in improved alignment and increased seal life. No isolation pads required.

OPTIONAL LOW NOISE FAN

RECIRCULATING PUMP

Recirculating Pump

Low Noise Fan

Copper is easy to work with, and has excellent thermal conductivity, corrosion resistance and durability.

Stainless steel casing.

Wide diagonal spacing for easy cleaning.

Type L copper.

Designed to block direct sunlight to the water, to minimize algae growth, reduce splash out and noise.

Fabricated from rigid, corrugated UV protected Polyvinyl Chloride (PVC); is easy removable to provide access for cleaning. Resistant to rot, fungi, bacteria and organic/inorganic acids and alkalis.

Meets CTI STD-136.

Flame spread rating is less than 20 according to ASTM E84, and self-extinguishing in less than 5 seconds according to ASTM D635.

COPPER COILS

AIR INLET LOUVERS

Durable, corrosion resistant copper coils.

Air Inlet Louvers

Manufactured of Polyvinyl Chloride (PVC); resistant to rot,

fungi, bacteria and organic/inorganic acids and alkalis

commonly found in cooling towers.

Meets CTI STD-136.

Fill media modules flame spread rating is less than 20

conforming to ASTM E84, and self-extinguishing in less

than 5 seconds conforming to ASTM D635.

Every tower is assembled and tested at the factory prior to shipment.

REYMSA has a deep commitment with customer satisfaction to build long term relationships.

FILM FILL MEDIA

Direct Drive System

Film Fill Media

All interior distribution piping is fabricated using standard PVC.

Water is evenly distributed over the fill media by removable ABS spray nozzles.

HOT WATER DISTRIBUTION SYSTEM

REYMSA COOLING TOWERS, INC. REYMSA COOLING TOWERS, INC.

BENEFITS

Page 6: Closed Circuit Fluid Cooler - HTS · Induced draft counterflow design. CTI certified in accordance with standard STD-201. Long life construction. 36 different models. ... CLOSED CIRCUIT

REYMSA COOLING TOWERS, INC.

PRINCIPLE OF OPERATION

Hot recirculating water is distributed over the fill media through spray nozzles.

Tower Fans draw ambient air into the tower, making contact with water through the fill.

Heat Transfer takes place between the water and the air using latent and sensible cooling.

Water is distributed externally over the copper tube heat exchanger using gravity nozzles.

Process Fluid circulates internally through the copper tube heat exchanger.

Heat transfer occurs between the outside exposed water and the contained process fluid. Protecting the integrity of the process fluid.

1.-

2.-

3.-

4.-

5.-

6.-

REYMSA COOLING TOWERS, INC.

CONSTRUCTION DETAILS (FRONT OF THE TOWER)

Fan Section

Drift Eliminator

Spray Nozzle Manifold

Body Section

Cellular Fill

Air Inlet Louvers

Basin Section

Water distribution System

Process Fluid Inlet

Process Fluid Outlet

Copper Coil

Recirculating Pump

7.

8.

9.

10.

11.

12.

1.

2.

3.

4.

5.

6.

Water

Page 7: Closed Circuit Fluid Cooler - HTS · Induced draft counterflow design. CTI certified in accordance with standard STD-201. Long life construction. 36 different models. ... CLOSED CIRCUIT

REYMSA COOLING TOWERS, INC.

PRINCIPLE OF OPERATION

Hot recirculating water is distributed over the fill media through spray nozzles.

Tower Fans draw ambient air into the tower, making contact with water through the fill.

Heat Transfer takes place between the water and the air using latent and sensible cooling.

Water is distributed externally over the copper tube heat exchanger using gravity nozzles.

Process Fluid circulates internally through the copper tube heat exchanger.

Heat transfer occurs between the outside exposed water and the contained process fluid. Protecting the integrity of the process fluid.

1.-

2.-

3.-

4.-

5.-

6.-

REYMSA COOLING TOWERS, INC.

CONSTRUCTION DETAILS (FRONT OF THE TOWER)

Fan Section

Drift Eliminator

Spray Nozzle Manifold

Body Section

Cellular Fill

Air Inlet Louvers

Basin Section

Water distribution System

Process Fluid Inlet

Process Fluid Outlet

Copper Coil

Recirculating Pump

7.

8.

9.

10.

11.

12.

1.

2.

3.

4.

5.

6.

Water

Page 8: Closed Circuit Fluid Cooler - HTS · Induced draft counterflow design. CTI certified in accordance with standard STD-201. Long life construction. 36 different models. ... CLOSED CIRCUIT

REYMSA COOLING TOWERS, INC. REYMSA COOLING TOWERS, INC.

GPM CAPACITY TABLE

CLOSED CIRCUIT FLUID COOLER(HFC-SERIES)

CONSTRUCTION DETAILS (BACK OF THE TOWER)

Drain

Purge

Water Make up

Overflow

Access Doors

13.

14.

15.

16.

17.

CAPACITY TABLE

Page 9: Closed Circuit Fluid Cooler - HTS · Induced draft counterflow design. CTI certified in accordance with standard STD-201. Long life construction. 36 different models. ... CLOSED CIRCUIT

REYMSA COOLING TOWERS, INC. REYMSA COOLING TOWERS, INC.

GPM CAPACITY TABLE

CLOSED CIRCUIT FLUID COOLER(HFC-SERIES)

CONSTRUCTION DETAILS (BACK OF THE TOWER)

Drain

Purge

Water Make up

Overflow

Access Doors

13.

14.

15.

16.

17.

CAPACITY TABLE

Page 10: Closed Circuit Fluid Cooler - HTS · Induced draft counterflow design. CTI certified in accordance with standard STD-201. Long life construction. 36 different models. ... CLOSED CIRCUIT

REYMSA COOLING TOWERS, INC. REYMSA COOLING TOWERS, INC.

ENGINEERING DATA & DIMENSIONS

CLOSED CIRCUIT FLUID COOLER (HFC-SERIES)

COIL PRESSURE DROP

CLOSED CIRCUIT FLUID COOLER(HFC-SERIES)

* A Nominal TON is defined as 3 GPM of water cooled from 95°F to 85°F with a 78°F entering wet bulb.

ENGINEERING DATA & DIMENSIONSCOIL PRESSURE DROP

w

H

L

L L

w

H

L

w

L

H

L

A B

C

A A A A A

Page 11: Closed Circuit Fluid Cooler - HTS · Induced draft counterflow design. CTI certified in accordance with standard STD-201. Long life construction. 36 different models. ... CLOSED CIRCUIT

REYMSA COOLING TOWERS, INC. REYMSA COOLING TOWERS, INC.

ENGINEERING DATA & DIMENSIONS

CLOSED CIRCUIT FLUID COOLER (HFC-SERIES)

COIL PRESSURE DROP

CLOSED CIRCUIT FLUID COOLER(HFC-SERIES)

* A Nominal TON is defined as 3 GPM of water cooled from 95°F to 85°F with a 78°F entering wet bulb.

ENGINEERING DATA & DIMENSIONSCOIL PRESSURE DROP

w

H

L

L L

w

H

L

w

L

H

L

A B

C

A A A A A

Page 12: Closed Circuit Fluid Cooler - HTS · Induced draft counterflow design. CTI certified in accordance with standard STD-201. Long life construction. 36 different models. ... CLOSED CIRCUIT

REYMSA COOLING TOWERS, INC.

Toll Free Number 1-866-445-2043

1641 World Trade Center, Millennium Industrial Park Laredo, Tx. 78045

Phone (210) 579-4837 Fax (210) 745-1513

[email protected] www.reymsa.com