Click to edit Master title style • Click to edit Master text styles • Second level • Third level • Fourth level • Fifth level 1 Applies to ALL lighting fixtures containing a Pulse Start or Probe Start Metal Halide Lamp Does Not Apply to High Pressure Sodium Changes are due to an Amendment to UL Standard 1598 Effective September 17, 2010 New MH HID Lamp Containment Rules
10
Embed
Click to edit Master title style Click to edit Master text styles Second level Third level Fourth level Fifth level 1 Applies to ALL lighting fixtures.
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Click to edit Master title style
• Click to edit Master text styles
• Second level
• Third level
• Fourth level
• Fifth level
1
Applies to ALL lighting fixtures containing a Pulse Start or Probe Start Metal Halide Lamp
Does Not Apply to High Pressure Sodium
Changes are due to an Amendment to UL Standard 1598
Effective September 17, 2010
New MH HID Lamp Containment Rules
Click to edit Master title style
• Click to edit Master text styles
• Second level
• Third level
• Fourth level
• Fifth level
2
New MH HID Lamp Containment Rules
The RULE
A pink exclusionary socket requires an “O” open rated lamp
Does not need a bottom lens
A standard white ceramic socket accepts an E rated lamp
Requires a compliant bottom lens
Click to edit Master title style
• Click to edit Master text styles
• Second level
• Third level
• Fourth level
• Fifth level
3
New MH HID Lamp Containment Rules
Type E & S Lamp in Standard WhiteMogul Socket
Type O Lamp in Standard WhiteMogul Socket
Lens Required with Std White Mogul Socket
Click to edit Master title style
• Click to edit Master text styles
• Second level
• Third level
• Fourth level
• Fifth level
4
New MH HID Lamp Containment Rules
Type E & S Lamp in Protected PinkMogul Socket
Type O Lamp in Protected PinkMogul Socket
No Lens Required with Pink EX socket
Click to edit Master title style
• Click to edit Master text styles
• Second level
• Third level
• Fourth level
• Fifth level
5
New MH HID Lamp Containment Rules
Standard Socket Exclusionary Socket
Click to edit Master title style
• Click to edit Master text styles
• Second level
• Third level
• Fourth level
• Fifth level
6
Pink Socket – No Bottom Lens Required Standard Socket – Bottom Lens Required
New MH HID Lamp Containment Rules
Click to edit Master title style
• Click to edit Master text styles
• Second level
• Third level
• Fourth level
• Fifth level
7
Timing:
Applies to all MH and PSMH Production after September 17th
Fixtures made prior to September 17th have a valid UL or CSA listing and are good to use.