CLEAVER-BROOKS 600 HP, 150 PSI BOILER Constructed 1981 in strict accordance with ASME Section I standards, stamped for 150 psi operation, four pass dry back design. Gas/#2 can be converted to heavy oil. Guaranteed to pass hydro, good tubes, good paint, available with new paint. MM-193 LWCO for modulating feed water. Ser. L-71106. Input: 25,200,000 BTU Gross Output: 20,100,000 BTU Steam Output: 20,700 pounds per hour MAWP: 150 psi Fuel: Natural Gas/ #2 oil Equipment List: ASME Section I shell, 3000 sq. ft. heating surface 2” insulation Painted galvanized jacket Full modulation Fireye E-110 Honeywell three pressuretrol set up, L404A, L404C, L91 McDonnel Miller 193 LWCO, MM 157 SLWCO Two new Kunkle safety relief valves Feedwater isolation and check valves 1 slow, 2 quick opening blowdown valves 8“ 300# flanged steam line connection, w/ valve 24” nominal stack diameter (flanged w/ damper) Dimensions: 284” overall length 128” height at stack (add approx. 8” for FWT) 118” width w/ controls 47,000 pounds shipping weight 480/60/3ph blower voltage, 120V control circuit BOYLE SERVICES, INC. 701 W. 41 st ST. TULSA, OK. 74107 1-800-772-6953 FAX: 918-446-1408 EMAIL: [email protected] Web: www.boyleservices.com
3

CLEAVER-BROOKS 600 HP, 150 PSI BOILERboyleservices.publishpath.com/Websites/boyleservices/images/CB-200-600... · CLEAVER-BROOKS 600 HP, 150 PSI BOILER Constructed 1981 in strict

Mar 23, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: CLEAVER-BROOKS 600 HP, 150 PSI BOILERboyleservices.publishpath.com/Websites/boyleservices/images/CB-200-600... · CLEAVER-BROOKS 600 HP, 150 PSI BOILER Constructed 1981 in strict

CLEAVER-BROOKS 600 HP, 150 PSI BOILER

Constructed 1981 in strict accordance with ASME Section I standards, stamped for 150 psi operation, four pass dry back design. Gas/#2 can be converted to

heavy oil. Guaranteed to pass hydro, good tubes, good paint, available with new paint. MM-193 LWCO for modulating feed water. Ser. L-71106.

Input: 25,200,000 BTU

Gross Output: 20,100,000 BTU Steam Output: 20,700 pounds per hour

MAWP: 150 psi Fuel: Natural Gas/ #2 oil

Equipment List:

ASME Section I shell, 3000 sq. ft. heating surface

2” insulation Painted galvanized jacket

Full modulation Fireye E-110

Honeywell three pressuretrol set up, L404A, L404C, L91 McDonnel Miller 193 LWCO, MM 157 SLWCO

Two new Kunkle safety relief valves Feedwater isolation and check valves

1 slow, 2 quick opening blowdown valves 8“ 300# flanged steam line connection, w/ valve 24” nominal stack diameter (flanged w/ damper)

Dimensions:

284” overall length

128” height at stack (add approx. 8” for FWT) 118” width w/ controls

47,000 pounds shipping weight 480/60/3ph blower voltage, 120V control circuit