www.masterwater.com Made in USA The Clarifier Series offers treatment solutions for corrosion, chlorine, taste, odor, discolored water and turbidity through filtration. APPLICATION GUIDE WATER ISSUE: Chlorine, musty, earthy odor/taste Recommended product: MCA-AC units WATER ISSUE: Blue/green stains, pipe pitting, appliance corrosion Recommended product: MCA-AN units WATER ISSUE: Turbidity Recommended product: MCA-MM units Product Versions Mineral Tank Cubic Feet Media Backwash Flow Service Flow Assembly Size (gpm) (gpm) MCA-AC-10 10” x 54” 1.5 3.2 6.0 MCA-AC-13 13” x 54” 2.0 4.2 8.0 MCA-AN-10 10” x 54” 1.5 5.3 5.0 MCA-AN-13 13” x 54” 2.0 7.5 7.0 MCA-MM-10 10” x 54” 1.5 6.5 6.0 MCA-MM-13 13” x 54” 2.0 10 8.0 Dome hole feature standard on AN units
2
Embed
Clarifier Series App Guide MCA - Master Water...Made in USA The Clarifier Series offers treatment solutions for corrosion, chlorine, taste, odor, discolored water and turbidity through
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
www.masterwater.comMade in USA
The Clarifier Series offers treatment solutions for corrosion, chlorine, taste, odor, discolored water and turbidity through filtration.
APPLICATION GUIDE
WATER ISSUE:Chlorine, musty, earthy odor/taste
Recommended product: MCA-AC units
WATER ISSUE:Blue/green stains, pipe pitting, appliance corrosionRecommended product: MCA-AN units
WATER ISSUE:TurbidityRecommended product: MCA-MM units
Product Versions Mineral Tank Cubic Feet Media Backwash Flow Service Flow Assembly Size (gpm) (gpm)
MCA-AC-10 10” x 54” 1.5 3.2 6.0
MCA-AC-13 13” x 54” 2.0 4.2 8.0
MCA-AN-10 10” x 54” 1.5 5.3 5.0
MCA-AN-13 13” x 54” 2.0 7.5 7.0
MCA-MM-10 10” x 54” 1.5 6.5 6.0
MCA-MM-13 13” x 54” 2.0 10 8.0
Dome hole feature
standard on AN units
www.masterwater.comMade in USA
1. Will the Clarifier Series unit fit within the allocated space in my home?
Check table for space required
2. Will the Clarifier Series unit meet my flow demand?
Check table for flowrate
* Depth size includes bypass and tail piece connection.
If above parameters cannot be used to determine system, call Master Water Conditioning.
Application notes: • Accurate water analysis is critical• Local conditions can influence system performance
APPLICATION GUIDE
CLARIFIERSERIES
SYSTEMS
System Sizebased on
bathrooms
Flowrate Requiredto operate system
Contaminant Limits
Application Notes
Total Dimensions*
MCA-AC UnitsCarbon
Chlorine/Taste/Odor
1–2 BathroomsMCA-AC-10
2.5–3 BathroomsMCA-AC-13
3.2 gpmMCA-AC-10
4.2 gpmMCA-AC-13
Turbidity ≤ 10 ntuTotal Chlorine ≤ 4 ppm
MCA-AC guidelines are based on dechlorination only.