This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
G B33RF900B_V12-11
C I V I L W O R K A N D I N S T A L L A T I O N M ‘ S T A R T
I N D E X1. No enclosure
Energy chain 6• Dimensions 6• Installation of parts 7
Catenary connection 8• Dimensions 8• Installation of parts 9
Measurements and cross sections 10• No underchassis wash 10• With underchassis wash 12
Electrical data 30• Installed on machine 30• on the machine 30• Electrical distribution cabinet 31
M O D . 4 P D 6 0 0 0
SAFETY 2SAFE PRACTICE AND SAFETY RULES
To guarantee your safety, please cooperate with the company at all times and obey the safety rules detailed here to help ensure that accidents are avoided. (Article 29. Safety at Work Act). The following list of obligations shall be respected by all workers carrying out work whether directly employed by ISTOBAL or subcontracted.
• Please make proper use of the personal protection equipment provided.
• Follow the instructions of your superiors, and any indications given by the person responsible for the facility.
• Keep tools and personal and collective protection equipment in good order. If you observe any deterioration in them, advise your superior immediately.
• Keep the work site clean and tidy.
• Advise your superiors and colleagues of any danger or risk that you perceive on the facility. In case of serious and imminent risk, do as indicated above while also ceasing to perform any activity which may add to such risk.
PREVENTIVE MEASURES
ISTOBAL, S.A. personnel and workers subcontracted by the company are to take into account the following preventive measures while carrying out work:
• Hand-held ladders are not permitted for performing jobs. For work where use of a scaffold is not physically possible or where its use would be an added risk, a platform step ladder is to be used.
• If a certified scaffold is used, follow the manufacturer's assembly instructions closely. Make sure it is in perfect condition before use. Do not place it near power lines. If the scaffold is moveable, put the brakes on all the wheels and use securing bars to stop it moving unexpectedly. Do not move the scaffold with workers on it. Do not leave tools or materials lying around on the scaffold.
• If a platform step ladder is used, it must only be used by duly trained and authorised personnel. Make sure that it is used in accordance with the instructions supplied with it.
• All waste generated is to be collected and removed from the work area as and when it is generated. The work area should be kept as clean as possible at all times.
• Make sure the work area is organised - do not leave materials and tools lying around as these could cause accidents.
• When materials are being loaded and unloaded with winches / cranes; materials are being lifted; heavy parts are being mounted, etc., make sure there are no workers underneath. Check this before starting to move anything.
CONDUCT ON SITE
• Station your vehicle in designated parking zones. Turn off the engine. Parking is not permitted in classified areas or where the vehicle would obstruct the passage of persons or vehicles.
• Inform the supervisor or person responsible for the facility of the presence of the vehicle and why it is there.
• Before starting work, put up signs and cordon off the areas where you will be setting up equipment such as winches, compressors, etc.
• After the work is completed, remove leftover waste from the work area, such as plastic, cardboard, wood, etc.
• Collect your tools and other equipment.
• Inform the Supervisor or person responsible for the facility that the work is completed and what the situation is now.
PROTECTION EQUIPMENT
Personal and collective protection equipment used should be appropriate to the task, certified with the mark, and display the corresponding inspection dates.
2
GB
SAFETY2Personal protection equipment should give effective protection against the risks they are intended for. Such equipment should not constitute a risk in itself nor cause unnecessary inconvenience. The equipment should:
• Respond to the conditions existing in the workplace.
• Take into account the anatomy, physiology, and state of health of the operator.
• Fit the bearer properly after the pertinent adjustments.
• Where multiple risks are involved which require several types of personal protection equipment to be used together, they should be mutually compatible and maintain their level of efficiency in relation to the corresponding risk or risks.
PERSONAL PROTECTION EQUIPMENT
COMPULSORY PROTECTION
Safety footwear.Mechanical protection, waterproof, and with a dielectric sole, anti-slip, and anti-perforation protection.
High visibility reflective vest.
Safety helmet.
Safety gloves.
OTHER PROTECTION DEPENDING ON THE WORK TO BE DONE
Tool belt.
3
GB
CIV
IL W
OR
K A
ND
IN
ST
AL
LA
TIO
N
SAFETY 2PERSONAL PROTECTION EQUIPMENT
OTHER PROTECTION DEPENDING ON THE WORK TO BE DONE
Safety harness.For work at a height of 2 m. and above.
Back support belt.For tasks which require unusual positions to be adopt-ed, or straining.
High impact safety goggles.Use of drills, radial saws, etc.
Ear protection.Use of drills, radial saws, etc.
Welding screens and masks with metal smoke filter.Use of welding sets.
4
GB
SAFETY2COLLECTIVE PROTECTION EQUIPMENT
Safety tape and conesTo indicate and cordon off the work area.
No entry sign.To prevent unauthorized access, and indicate the need for PPE to be worn.
Portable fire extinguisher.
Fire blankets For work generating heat (welding, radial saws, etc.).
5
GB
CIV
IL W
OR
K A
ND
IN
ST
AL
LA
TIO
N
6
G B
NO ENCLOSURE
Between rails: 2700±5
Between rails: 2854±5
Between rails: 2500±5
No enclosure Energy chainDimensions
The distance between the underside of the foot and the floor must not exceed 10 mm.If the space K or L is smaller than recommended (500 mm), you will need to install the anti-smashing system and wire or rubber switch.
Without cutting supporting arm 4924 4924 4924 4924 4924 4924
F Chassis height 3113 3113 3313 3313 3513 3513
HRecommended 2260 2260 2260 2260 2260 2260
Minimum 2040 2040 2040 2040 2040 2040
Without cutting supporting arm 2664 2664 2664 2664 2664 2664
KRecommended 500 500 500 500 500 500
Minimum 280 280 280 280 280 280
Without cutting supporting arm 904 904 904 904 904 904
LRecommended 500 500 500 500 500 500
Minimum 200 200 200 200 200 200
M Max. vehicle length 6000 7000 6000 7000 6000 7000
N Bay length 9500 10500 9500 10500 9500 10500
P Between centres of posts 4320 4820 4320 4820 4320 4820
Q Between centres of rails 2854 2854 2854 2854 2854 2854
Y Between centring guides 2050 2050 2050 2050 2050 2050
Measurements in mm.
8
G B
NO ENCLOSURE
The distance between the underside of the foot and the floor must not exceed 10 mm.If the space K or L is smaller than recommended (500 mm), you will need to install the anti-smashing system and wire or rubber switch. Measurements in mm.
W Length of entry grid, no Under chassis wash 3500 4500 3500 4500 3500 4500
Surface of bay treated with non-slip finish.Any guarantees as to the dimensions of the concrete beds depend on the floor being properly compacted.The dimensions of the frames and grates can be consulted on page 15.
A
B
C C’
B’
D’ D
A’
S
T
N
W
Q
Measurements in mm.
11
G B
CIV
IL W
OR
K A
ND
IN
ST
AL
LA
TIO
N
NO ENCLOSURE
Energy chain or catenary connection, right or left (depending on the layout of the facility).
SECTION A - A’
SECTION B - B’
SECTION C - C’
SECTION D - D’
HEA Section 100x9000 mmNot supplied by Istobal SA
Rebar mat 150x150x6 mm B 500 s
Rebar mat 150x150x6 mm B 500 s
Rebar mat 150x150x6 mm B 500 s Rebar mat 150x150x6 mm B 500 s
Rebar mat 150x150x6 mm B 500 s
PVC pipe D160 mm LPN 30x3 mm
Drain pipe D50 mm
Hollow brick wall 250x120x90 laid with M-40 morter
U Length of entry grid, with Under chassis wash 2000 3000 2000 3000 2000 3000
Surface of bay treated with non-slip finish.Any guarantees as to the dimensions of the concrete beds depend on the floor being properly compacted. The dimensions of the frames and grates can be consulted on page 15.
S
T
N
U
Q
Measurements in mm.
13
G B
CIV
IL W
OR
K A
ND
IN
ST
AL
LA
TIO
N
NO ENCLOSURE
Energy chain or catenary connection, right or left (depending on the layout of the facility).
SECTION A - A’
SECTION B - B’
SECTION C - C’
SECTION D - D’
HEA Section 100x9000MMNot supplied by Istobal SA
Rebar mat 150x150x6 mm B 500 s
Rebar mat 150x150x6 mm B 500 s
Rebar mat 150x150x6 mm B 500 s Rebar mat 150x150x6 mm B 500 s
PVC pipe D160 mm LPN 30x3 mm
Drain pipe D50 mm
Hollow brick wall 250x120x90 laid with M-40 morter
Rebar mat 150x150x6 mm B 500 s
Measurements in mm.
Concrete FCK=25 n/mm2
Macadam
14
G B
NO ENCLOSURE
PipingOverground underchassis wash Mod. 4827400
Fitted underchassis wash Mod. 4300400 or 4300700
Self-service command post
Positioning by platform
To main drain
To shop terminal for self-service code
A Flexible PVC pipe D50 mmB PVC pipe D160 mmC PVC pipe D30 mmD 1” pipe DIN 24401 Energy chain connection box2 Catenary connection box
Self-service command post
Positioning by platform
To main drain
To shop terminal for self-service code
Measurements in mm.
B
A
A
A
A
A
A
A
A
A
A
B
D C
D C
1 2
1 2
15
G B
CIV
IL W
OR
K A
ND
IN
ST
AL
LA
TIO
N
NO ENCLOSURE
Frames and gratesFrame for fitted underchassis wash (not supplied by Istobal).
Grate with 820x1516mm frame ref. 2375600 (optional)
Anchoring
“L” Section 60x60x8 mm
Prefabricated guttering
Prefabricated guttering
Prefabricated guttering
Prefabricated guttering
Measurements in mm.
16
G B
WITH ENCLOSURE
With enclosure Energy chainDimensions
Measurements in mm.
Between rails: 2700±5
Between rails: 2854±5
Between rails: 2500±5
Left side connection
Right side connection
MC
Q
R
P
A
G
J
H
E
Z
Detail Z
Detail YY
The distance between the underside of the foot and the floor must not exceed 10 mm.With the enclosure of 4500 mm. you will need to install the anti-smashing system and wire or rubber switch.
Without cutting supporting arm 4924 4924 4924 4924 4924 4924
GRecommended 3550 3550 3750 3750 3950 3950
Minimum 3150 3150 3350 3350 3550 3550
HRecommended 2260 2260 2260 2260 2260 2260
Minimum 2040 2040 2040 2040 2040 2040
Without cutting supporting arm 2664 2664 2664 2664 2664 2664
J Height service line 3084 3084 3284 3284 3484 3484
M Max. vehicle length 6000 7000 6000 7000 6000 7000
P Between centres of posts 4320 4820 4320 4820 4320 4820
Q Between centres of rails 2854 2854 2854 2854 2854 2854
R Length bay enclosure 10100 11100 10100 11100 10100 11100
Y Between centring guides 2050 2050 2050 2050 2050 2050
Installation of parts
18
G B
WITH ENCLOSURE
Catenary connectionDimensions
Between rails: 2700±5
Between rails: 2854±5
Between rails: 2500±5
Left side connection
Right side connection
MC
Q
R
P
A
GJ
H
E
Z
Detail Z
Detail YY
Measurements in mm.
The distance between the underside of the foot and the floor must not exceed 10 mm.With the enclosure of 4500 mm. you will need to install the anti-smashing system and wire or rubber switch.
Without cutting supporting arm 4924 4924 4924 4924 4924 4924
GRecommended 3550 3550 3750 3750 3950 3950
Minimum 3150 3150 3350 3350 3550 3550
HRecommended 2260 2260 2260 2260 2260 2260
Minimum 2040 2040 2040 2040 2040 2040
Without cutting supporting arm 2664 2664 2664 2664 2664 2664
J Height service line 2364 2364 2564 2564 2764 2764
M Max. vehicle length 6000 7000 6000 7000 6000 7000
P Between centres of posts 3950 4950 3950 4950 3950 4950
Q Between centres of rails 2854 2854 2854 2854 2854 2854
R Length bay enclosure 10100 11100 10100 11100 10100 11100
Y Between centring guides 2050 2050 2050 2050 2050 2050
Y
Installation of parts
Measurements in mm.
20
G B
WITH ENCLOSURE
Surface of bay treated with non-slip finish.Any guarantees as to the dimensions of the concrete beds depend on the floor being properly compacted. The dimensions of the frames and grates can be consulted on page 25.
A
B
C C’
B’
D’ D
A’
V
Q
R
W
Measurements in mm.
Measurements and cross sectionsNo underchassis wash
A Max. vehicle height 2300 2500 2700B Max. vehicle width 2400C Rail length 9000 10000 9000 10000 9000 10000Q Between centres of rails 2854 2854 2854 2854 2854 2854
R Length bay enclosure 10100 11100 10100 11100 10100 11100
VWidth for enclosure 4.5 m. 5000 5000 5000 5000 5000 5000
Width for enclosure 4.8 m. 5300 5300 5300 5300 5300 5300
W Length of entry grid, no Underchassis wash 3500 4500 3500 4500 3500 4500
21
G B
CIV
IL W
OR
K A
ND
IN
ST
AL
LA
TIO
N
SECTION C - C’
SECTION D - D’
WITH ENCLOSURE
Energy chain or catenary connection, right or left (depending on the layout of the facility).
SECTION A - A’
SECTION B - B’
HEA Section 100x9000 mmNot supplied by Istobal SA
Rebar mat 150x150x6 mm B 500 s
Rebar mat 150x150x6 mm B 500 s
Rebar mat 150x150x6 mm B 500 s
PVC pipe D160 mm LPN 30x3 mm
Drain pipe D50 mm
Hollow brick wall 250x120x90 laid with M-40 morter
AEH-400 NAEH-400 N
AEH-400 N AEH-400 N
Measurements in mm.
Concrete FCK=25 n/mm2
Macadam
Rebar mat 150x150x6 mm B 500 s Rebar mat 150x150x6 mm B 500 s
22
G B
WITH ENCLOSURE
Surface of bay treated with non-slip finish.Any guarantees as to the dimensions of the concrete beds depend on the floor being properly compacted. The dimensions of the frames and grates can be consulted on page 25.
With underchassis wash
Measurements in mm.
V
Q
R
U
A
B
C C’
B’
D’ D
A’
A Max. vehicle height 2300 2500 2700B Max. vehicle width 2400C Rail length 9000 10000 9000 10000 9000 10000Q Between centres of rails 2854 2854 2854 2854 2854 2854
R Length bay enclosure 10100 11100 10100 11100 10100 11100
U Length of entry grid, with Under chassis wash 2000 3000 2000 3000 2000 3000
VWidth for enclosure 4.5 m. 5000 5000 5000 5000 5000 5000
Width for enclosure 4.8 m. 5300 5300 5300 5300 5300 5300
23
G B
CIV
IL W
OR
K A
ND
IN
ST
AL
LA
TIO
N
WITH ENCLOSURE
Energy chain or catenary connection, right or left (depending on the layout of the facility).
SECTION A - A’
SECTION B - B’
SECTION C - C’
SECTION D - D’
HEA Section 100x9000 mmNot supplied by Istobal SA
Rebar mat 150x150x6 mm B 500 s
Rebar mat 150x150x6 mm B 500 s
PVC pipe D160 mm LPN 30x3 mm
AEH-400 NAEH-400 N
AEH-400 N AEH-400 N
Drain pipe D50 mm
Hollow brick wall 250x120x90 laid with M-40
morter
Rebar mat 150x150x6 mm B 500 s
Rebar mat 150x150x6 mm B 500 s
Rebar mat 150x150x6 mm B 500 s
Measurements in mm.
Concrete FCK=25 n/mm2
Macadam
24
G B
WITH ENCLOSURE
A Flexible PVC pipe D50 mmB PVC pipe D160 mmC PVC pipe D30 mmD 1” pipe DIN 24401 Energy chain connection box2 Catenary connection box
PipingOverground underchassis wash Mod. 4827400
Measurements in mm.
Fitted underchassis wash Mod. 4300400 or 4300700
Self-service command post
Positioning by platform
To main drain
To shop terminal for self-service code
Self-service command post
Positioning by platform
To main drain
To shop terminal for self-service code
B
A
A
A
A
A
A
A
A
A1 2
A
B
D C
D C
1 2
25
G B
CIV
IL W
OR
K A
ND
IN
ST
AL
LA
TIO
N
WITH ENCLOSURE
Frames and gratesFrame for fitted underchassis wash (not supplied by Istobal).
Grate with 820x1516mm frame ref. 2375600 (optional)