Top Banner
Design Loads
45
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
  • Design Loads

  • Dead Loads

    o An engineered design approach involves calculating a demand due to loads, and comparing the demand with the capacity of the member or element under consideration.

    o Gravity (dead) loads are a natural starting point

    dead load is an ever-present load

    It is necessary to determine the magnitude of the vertical loads before the design seismic loads can be estimated.

    2 /45

  • Dead Loads

    Weights of all materials permanently attached to the structure including the following:

    o weight of the roof or wood floor system

    o sheathing

    o framing

    o Insulation

    o ceiling

    o piping, automatic fire sprinkler, ducts

    o fixed equipment

    o etc. 3 /45

  • Table 204-2 Minimum Design Dead Loads (kPa) [use actual when available]

    CEILINGS

    Asphalt singles . . . . . . . . . . . . . . . . . . . . . . . . .0.10

    Cement tile . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.77

    Clay tile (for mortar add 0.48 kPa)

    Book tile, 50 mm . . . . . . . . . . . . . . . . . . . . 0.52

    Book tile, 75 mm . . . . . . . . . . . . . . . . . . . . . 0.96

    Ladowici . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.48

    Roman . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.57

    Spanish . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.91

    Composition

    Three-ply ready roofing . . . . . . . . . . . . . . . .0.05

    Four-ply felt and gravel . . . . . . . . . . . . . . . .0.26

    Five-ply felt and gravel . . . . . . . . . . . . . . . . .0.29

    Copper or tin . . . . . . . . . . . . . . . . . . . . . . . . . . .0.05

    Corrugated asbestos-cement roofing . . . . . . .0.19

    Deck, metal 20 gage . . . . . . . . . . . . . . . . . . . . .0.12

    Deck, metal 18 gage . . . . . . . . . . . . . . . . . . . . .0.14

    Fiberboard, 13 mm . . . . . . . . . . . . . . . . . . . . .0.04

    Gypsum sheathing, 13 mm . . . . . . . . . . . . . . .0.10

    COVERINGS, Roof and Wall

    Acoustical Fiber Board . . . . . . . . . . . . . . . . . . 0.05

    Gypsum Board (per mm thickness) . . . . . . . 0.008

    Mechanical duct allowance . . . . . . . . . . . . . . 0.20

    Plaster on tile or concrete . . . . . . . . . . . . . . . 0.24

    Plaster on wood lath . . . . . . . . . . . . . . . . . . . . .0.38

    Suspended steel channel system . . . . . . . . . . 0.10

    Suspended metal lath and cement plaster . . 0.72

    Suspended metal lath and gypsum plaster . . .0.48

    Wood furring suspension system . . . . . . . . . . 0.12

  • Sample Dead Load Calculation

    Roof Dead loads D in psf

    Roofing (5ply with gravel) 6.5

    Reroofing 2.5

    - in. plywood (3 psf x .) 1.5

    Framing (estimate 2 x 12 @ 16 o.c.) 2.9

    Insulation 0.5

    Suspended ceiling (acoustical tile) 1.0

    Roof dead load D 14.9 ~ 15.0 psf

    5 /45

  • Sample Dead Load Calculation

    Floor Dead loads D in psf

    Floor covering (lightweight concrete 1 at 100 pcf) 12.5

    1-1/8 plywood (3 psf x 1-1/8 ) 3.4

    Framing (4 x 12 @ 4 o.c.) 2.5

    Ceiling supports (2 x 4 @ 24 o.c.) 0.6

    Ceiling ( drywall, 5 psf x ) 2.5

    Floor dead load D 21.5 ~ 22.0 psf

    6 /45

  • Live Loads

    o Lr roof live load, including any permitted live load reduction

    o L live load, including any permitted live load reduction

    o For the reduction of both Lr and L, the area contribution load to the member under design consideration is taken into account.

    for roof live load (Lr), the tributary area is used

    for floor live load (L), the influence area is used 7 /45

  • NSCP Live Loads

    Table 205-1 Minimum Uniform and Concentrated Live Loads

    Use or Occupancy Uniform Load2 Concentrated Load

    Category Description KPa KN

    13. Office

    Call Centers and BPO 2.9 9.0

    Lobbies and ground floor corridors 4.8 9.0

    Offices 2.4 9.02

    Building corridors above ground floor 3.8 9.0

    14. Printing plants

    Press rooms 7.2 11.02

    Composing and linotype rooms 4.8 9.02

    15. Residential8

    Basic floor area 1.9 06

    Exterior balconies 2.94 0

    Decks 1.94 0

    Storage 1.9 0

    8 /45

  • NSCP Live Loads

    Use or Occupancy Vertical Load (kPa)

    Lateral Load (kPa)

    Category Description

    1. Construction, public access at site (live load)

    Walkway 7.2 -

    Canopy 7.2 -

    2. Grandstands, reviewing, stands bleachers, and folding and telescoping seating (live load0

    Seats and footboards 1.75 -

    3. Stage accessories (live load)

    Catwalks 1.9 -

    Follow spot, projection and control rooms 2.4 -

    4. Ceiling framing (live load)

    Over stages 1.0 -

    All uses except over stages 0.5 -

    Table 205-2 Special Loads

    9 /45

  • Tributary Area, AT

    o Tributary area - the area assumed to load a given member

    o generally measured from midway between members on one side of the member under consideration to midway between members on the other side.

    o for members spaced a uniform distance apart, the tributary width is equivalent to the spacing between members

    o since tributary areas for adjacent members do not overlap, all distributed loads are assumed to be supported by the nearest structural member

    Note: tributary area approach should only be used when the loading is uniform

    10 /45

  • Influence Area, KLLAT

    o In contrast to the tributary approach, the influence area recognizes that the total load experience by a structural member maybe influenced by loads applied outside the tributary area of the member

    NSCP 205.6 Alternate Floor Live Load Reduction

    o The influence area is four times the tributary area for a column

    o Two times the tributary area for a beam, equal to the panel area for a two-way slab

    11 /45

  • Tributary Area

    12 /45

  • Tributary Area Calculations

    AT (ft2) KLLAT (ft

    2)

    Joist J1 2 x 12 = 24 2 x 24 = 48

    Joist J2 2 x 14 = 28 2 x 28 = 56

    Girder G1 (12/2 + 14/2)20 = 260 2 x 260 = 520

    Girder G2 (12/2 + 14/2) 24 = 312 2 x 312 = 624

    Interior col. C1 (12/2 + 14/2) (20/2 + 24/2) = 286 4 x 286 = 1144

    Exterior col. C2 (20/2 + 24/2) 12/2)= 132 4 x 132 = 528

    Corner col. C3 (14/2)(20/2) = 70 4 x 70 = 280

    13 /45

  • Reduction of Floor Live Loads

    [NSCP 205.6 ] Alternate Floor Live Load Reduction

    The unit live loads maybe reduced in accordance with the equation shown on any member, including flat slabs, having an influence area of 40 m2 or more

    Note: The reduced live load shall not be less than 50% of the unit live load for members receiving load from one level only, nor less that 40 percent of the unit live load for other members.

    = 0.25 + 4.57 1

    Ai = Influence area, m2

    L = reduced design live load per square meter of area supported by the member

    Lo = unreduced design live load per square meter of area supported by the member (Table 205-1)

    14 /45

  • Seatwork

    Determine the following:

    (a) tributary and influence areas are for J1, J2, G1, G2, C1 and C2

    (b) axial force required for the design of the interior column C1 due to a dead load of 0.2 kPa and a floor live load L = 1.9 kPa.

    15 /45

  • Roof Live Loads

    o The live load on a roof is usually applied for a relatively short period of time during the life of the structure

    o This is normally of no concern in the design of structures other than wood

    o However in wood structures, the length of time for which a load is applied does have an effect on the capacity (resistance) of the member.

    o The standard roof live load for small tributary areas on flat roofs is 20 psf (1 kPa)

    16 /45

  • Reduction of Roof Live Loads

    AT = tributary area supported by structural member, ft2

    F = the number of inches or rise per foot for a sloped roof

    Lo = minimum uniform live load per ASCE 7-10 Table 4-1

    = 012 12 20

    2 = 1

    1.2 0.050.6

    4 4 < < 12

    12

    and

    1 = 1

    1.2 0.0010.6

    200 2

    200 < < 600 2

    600 2

  • NSCP Roof Live Loads

    ROOF SLOPE

    Method 1 Method 2

    Tributary Area (m2) Uniform Load (kPa)

    Rate of Reduction,

    r

    Maximum Reduction R (percentage) 0 to 20 20 to 60 > 60

    Uniform Load (kPa)

    1. Flat or rise less than 4 units vertical in 12 units horizontal (33.3% slope). Arch and dome with rise less than one-eight of span.

    1.00

    0.75

    0.60

    1.00

    0.08

    40

    2. Rise 4 units vertical to less than 12 units vertical in 12 units horizontal (33.3% to less than 100% slope). Arch and dome with rise one-eight of span to less than three-eights of span.

    0.75

    0.70

    0.60

    0.75

    0.06

    25

    3. Rise 12 units vertical in 12 units horizontal (100% slope) and greater. Arch of dome with rise three-eights of span or greater.

    0.60

    0.60

    0.60

    0.60

    No reduction permitted 4. Awnings except cloth covered. 0.25 0.25 0.25 0.25

    5. Greenhouses, lath houses and agricultural building. 0.50 0.50 0.50 0.50

    Table 205-3 Minimum Roof Live Loads

  • Example Problem

    Determine the uniformly distributed roof loads (including dead load and roof live load) for the purlins and girders in the building shown.

    Also determine the total load on column C1.

    Assume that the roof is flat (except for a minimum slope of in/ft for drainage).

    Roof dead load D = 8 psf.

    19 /45

  • Combined Dead and Live on Sloping Roof

    = 12 +

    = + 21

    Load on horizontal plane:

    Load along roof slope:

    Equivalent total roof loads (D + Lr):

    Combined D + Lr on sloping roof

    L2 Lr from NSCP

    Horizontal Roof D along roof slope

    20 /45

  • Example Problem

    The building is a standard residential occupancy. The rafters are sloped at 6 in./ft, and the roof covering consists of cement asbestos shingles.

    Determine the shear and moment for the rafters under dead plus live load if they are spaced 4 ft o.c.

    Roof dead load D has been estimated as 14 psf along the roof surface.

    18

    Lr = 62 psf

    D = 14 psf

    18

    6

    12

    Rafters @ 4 o.c. Ridge beam

    q

  • Other Loads

    o Soil Loads and Hydrostatic Pressure (H)

    soil lateral loading most commonly occurs at retaining walls

    where retaining walls are provided, it is possible to develop hydrostatic pressure

    it is also possible to have upward hydrostatic pressures on adjacent floor slabs

    pressure can also be due to storage of grain, aggregates, or other bulk solids that can exert lateral pressures

    22 /45

  • Other Loads

    o Loads due to Fluids (F)

    not intended to address flood loads or hydrostatic pressure

    when fluids are contained in non-building structures or nonstructural components, other standards might be applicable and can provide guidance in the design

    o Rain Loads (R)

    primarily applicable to low slope roofs that are surrounded by parapets

    need not be considered for sloped roofs that cannot develop water buildup

    23 /45

  • Other Loads

    o Flood Loads (F)

    Section 211 of the NSCP

    applies to buildings and other structures located in areas prone to flooding as defined on a flood hazard map

    o Snow Loads (not applicable)

    o Self-straining Loads

    loads arising from temperature change, moisture change, creep, movement due to differential settlement or combinations thereof

    o Earthquake Loads

    NSCP Section 208

    will not be considered in this course 24 /45

  • Other Loads

    o Wind Loads (NSCP Section 207)

    Method 1 simplified procedure

    can be used for the large majority of wood frame buildings

    Method 2 analytical procedure

    can be used for determining wind loads on structures of all sizes, configurations and exposure conditions

    requires defining more variables than Method 1

    Method 3 wind tunnel procedure

    for complex buildings that might be anticipated to have unusual dynamic behavior

    Limited to a small group of buildings for which the time and expense of a detailed study can be justified

    25 /45

  • Method 1 Simplified Method

    o Main wind-force-resisting system (MWFRS) - is a system providing wind resistance for the overall structure.

    o In wood frame buildings, the MWFRS most commonly consists of

    Shearwalls sheathed walls that resist in-plane loads

    Roof and floor diaphragms sheath floor and roof assemblies that transmit in-plane loads to the shearwalls

    26 /45

  • Method 1 conditions (NSCP 207.4.1.1)

    conditions for the MWFRS to be designed using Method 1

    o simple diaphragm building

    Both windward and leeward loads are transmitted through the floor and roof diaphragms to the same MWFRS

    o building is low rise

    has a mean roof height h less than or equal to 18 m

    mean roof height h does not exceed least horizontal dimension

    27 /45

  • Method 1 conditions (NSCP 207.4.1.1)

    conditions for the MWFRS to be designed using Method 1

    o building is enclosed

    meets requirements for wind-borne debris protection, if applicable

    o building is regular

    has no unusual geometrical irregularity in spatial form

    o building is not classified as a flexible building

    has a fundamental frequency greater than 1 hertz (fundamental period less than 1 second)

    28 /45

  • Method 1 conditions (NSCP 207.4.1.1)

    conditions for the MWFRS to be designed using Method 1

    o building does not have response characteristics that create unusual loading (such as galloping or vortex shedding)

    o not sited in a location where unusual wind load effects might occur

    o building has an approximately symmetrical cross section in each direction

    o has a flat roof or a gable or hip roof with slope less than or equal to 45 degrees (12 in 12 pitch)

    29 /45

  • Method 1 conditions (NSCP 207.4.1.1)

    conditions for the MWFRS to be designed using Method 1

    o has a flat roof or a gable or hip roof with slope less than or equal to 45 degree

    o Building is exempted from the torsional load cases as indicated in Note 5 of Figure 207-10, or the torsional load cases defined in Note 5 do not control the design of any of the MWFRSs of the building

    30 /45

  • NSCP 207.4.2.1

    For the design of MWFRS the basic formula for calculating design wind pressure ps is :

    For components and cladding, the basic formula for calculating design wind pressure pnet is

    = 9

    = 9

    l = adjustment factor for building height and exposure from Figures 207-2A and 207-3

    Iw = Importance factor

    Kzt = topographic factor as defined in Section 207.5.7

    ps9 = simplified design wind pressure for Exposure B at h = 9m and Iw = 1.0 from Figure 207-2 kPa

    pnet9 = net design wind pressure for Exposure B at h = 9 m and Iw = 1.0 from Figure 207-3 kPa

    31 /45

  • Adjustment Factor for Building Height and Exposure l

    Mean roof height (m)

    Exposure

    B C D

    4.5 1.00 1.21 1.47

    6.0 1.00 1.29 1.55

    7.5 1.00 1.35 1.61

    9.0 1.00 1.40 1.66

    11.0 1.05 1.45 1.70

    12.0 1.09 1.49 1.74

    13.7 1.12 1.53 1.78

    15.2 1.16 1.56 1.81

    16.8 1.19 1.59 1.84

    18.0 1.22 1.62 1.87

    32 /45

  • Design Wind Pressures on Walls and Roofs of Enclosed Buildings

    Basic Wind Speed (kph)

    Roof Angle

    (o)

    Load Case

    Horizontal Pressures, kPa Vertical Pressures, kPa Overhangs

    A B C D E F G H Eoh Goh

    150

    0 to 5 1 0.66 -0.34 0.44 -0.21 -0.79 -0.45 -0.55 -0.35 -1.11 -0.87

    10 1 0.75 -0.31 0.50 -0.18 -0.79 -0.48 -0.55 -0.37 -1.11 -0.87

    15 1 0.83 -0.28 0.55 -0.16 -0.79 -0.52 -0.55 -0.40 -1.11 -0.87

    20 1 0.92 -0.24 0.61 -0.13 -0.79 -0.55 -0.55 -0.42 -1.11 -0.87

    1 0.83 0.13 0.60 0.14 -0.37 -0.50 -0.27 -0.40 -0.69 -0.59

    25 2 0.00 0.00 0.00 0.00 -0.14 -0.27 -0.04 -0.18 0.00 0.00

    1 0.74 0.51 0.59 0.41 0.06 -0.45 0.02 -0.39 -0.26 -0.30

    30 to 45 2 0.74 -0.08 0.59 0.41 0.29 -0.22 0.25 -0.16 -0.26 -0.30

    33 /45

  • Design Wind Pressures on Walls and Roofs of Enclosed Buildings

    Basic Wind Speed (kph)

    Roof Angle

    (o)

    Load Case

    Horizontal Pressures, kPa Vertical Pressures, kPa Overhangs

    A B C D E F G H Eoh Goh

    200

    0 to 5 1 1.18 -0.62 0.79 -0.36 -1.42 -0.81 -0.99 -0.63 -2.00 -1.57

    10 1 1.34 -0.56 0.89 -0.32 -1.42 -0.87 -0.99 -0.67 -2.00 -1.57

    15 1 1.49 -0.49 0.99 -0.28 -1.42 -0.93 -0.99 -0.71 -2.00 -1.57

    20 1 1.64 -0.43 1.10 -0.24 -1.42 -0.99 -0.99 -0.75 -2.00 -1.57

    1 1.48 0.24 1.08 0.24 -0.66 -0.90 -0.48 -0.72 -1.23 -1.05

    25 2 - - - - -0.25 -0.49 -0.07 -0.31 - -

    1 1.34 0.91 1.06 0.73 0.11 -0.81 0.04 -0.69 -0.47 -0.54

    30 to 45 2 1.34 0.91 1.06 0.73 0.51 -0.40 0.45 -0.29 -0.47 -0.54

    34 /45

  • Design Wind Pressures on Walls and Roofs of Enclosed Buildings

    Basic Wind Speed (kph)

    Roof Angle

    (o)

    Load Case

    Horizontal Pressures, kPa Vertical Pressures, kPa Overhangs

    A B C D E F G H Eoh Goh

    250

    0 to 5 1 1.84 -0.95 1.22 -0.57 -2.21 -1.26 -1.54 -0.97 -3.09 -2.42

    10 1 2.07 -0.86 1.38 -0.50 -2.21 -1.35 -1.54 -1.04 -3.09 -2.42

    15 1 2.31 -0.77 1.54 -0.44 -2.21 -1.44 -1.54 -1.10 -3.09 -2.42

    20 1 2.54 -0.67 1.70 -0.37 -2.21 -1.54 -1.54 -1.17 -3.09 -2.42

    1 2.31 0.37 1.67 0.38 -1.03 -1.40 -0.74 -1.12 -1.91 -1.63

    25 2 - - - - -0.39 -0.76 -0.11 -0.49 - -

    1 2.07 1.41 1.65 1.13 0.16 -1.26 0.05 -1.08 -0.73 -0.83

    30 to 45 2 2.07 1.41 1.65 1.13 0.79 -0.62 0.69 -0.44 -0.73 -0.83

    35 /45

  • Notes

    207.1.4.1. Main Wind-Force Resisting System

    The wind load to be used in the design of the MWFRS for an enclosed or partially enclosed building or other structure shall not be less than 0.5 kPa multiplied by the area of the building or structure projected onto a vertical plane normal to the assumed wind direction.

    207.4.2.1.1 Minimum pressures

    The load effects of the design wind pressures from Section 207.4.2.1 shall not be less than the minimum load case from Section 207.1.4.1 assuming the pressures, ps, for zones A, B, C and D are all equal to +0.50 kPa, while assuming zones E, F, G and H all equal to 0 kPa.

    36 /45

  • notes

    o The dimension is a defined as

    10% of least horizontal dimension

    0.4hmean whichever is smaller.

    However a may not be taken less than 0.9m (3) or less than 4% of least horizontal dimension.

    37 /45

  • Referenced Wind Zone Map and Importance Factor

    Table 207-3 Importance Factor, Iw (Wind Loads)

    Occupancy Category2

    Description Iw

    I Essential 1.15

    II Hazardous 1.15

    III Special Occupancy 1.15

    IV Standard Occupancy 1.00

    V Miscellaneous 0.87

    1see Table 103-1 for types of occupancy under each category

    Figure 207-24 Referenced Wind Zone Map of the Philippines

  • Topographical Factor Kzt

    207.5.7 Topographic Effects

    o accounts for significantly higher wind speeds at sites located on the upper half of an exposed hill, ridge or escarpment

    o Kzt = 1.0 except for very exposed sites

    o NSCP provides a series of five (5) criteria, all of which must be met in order to require evaluation for a Kzt of other than 1.0

    39 /45

  • Topographical Factor Kzt

    207.5.7.2 Topographic Factor

    o The wind speed-up effect shall be included in the calculation of design wind loads by using the factor Kzt

    where K1, K2 and K3 are given in Figure 207-4.

    o If site conditions and locations of structures do not meet all the conditions specified in Section 207.5.7.1 the Kzt = 1.0.

    = 1 + 123 2

    40 /45

  • Topographical Factor Kzt

    41 /45

  • Example Problem Wind Forces for MWRFS

    Determine the design wind pressures based on the simplified method for the primary Lateral Force Resisting System (LRFS).

    This is a gable structure that uses a system of diaphragms and shear walls for resisting lateral forces.

    The building is a standard occupancy enclosed structure located in Zone 2. Exposure C is to be used, Kzt is 1.0.

    Wind forces for designing MWFRS are obtained based on ps9 from NSCP. End zone and interior zone locations to be considered for horizontal pressures on the vertical projection of the building surface

    Wind pressure zones on vertical and horizontal projections of building surfaces for MWFRS; wind direction parallel to transverse walls (end walls).

    Zone A (wall end zone)

    Zone B (roof end zone)

    Zone C (wall interior zone)

    Zone D (roof interior zone) 42 /45

  • Example Problem Wind Forces for MWRFS

    Wind pressure zones on vertical and horizontal projections of building surfaces for MWFRS; wind direction perpendicular to transverse walls (end walls).

    Zone E (windward roof end zone)

    Zone F (leeward roof end zone)

    Zone G (windward roof interior zone)

    Zone H (leeward roof interior zone)

    Determine the design wind pressures based on the simplified method for the primary Lateral Force Resisting System (LRFS).

    This is a gable structure that uses a system of diaphragms and shear walls for resisting lateral forces.

    The building is a standard occupancy enclosed structure located in Zone 2. Exposure C is to be used, Kzt is 1.0.

    Wind forces for designing MWFRS are obtained based on ps9 from NSCP. End zone and interior zone locations to be considered for horizontal pressures on the vertical projection of the building surface

  • Wind Forces for MWRFS o wind Speed = 200 kph (zone 2, p. 2-72)

    o Exposure C (No overhangs)

    o total height of building = 5.8 m

    o eave height = 3.6 m

    Windward Leeward

    Wind

    direction

    3.6 m

    2.2 m

    Interior zone

    End zone

    12.8 m

    -0.52 kPa

    -0.29 kPa

    2.00 kPa

    1.34 kPa

    -1.73 kPa

    -1.21 kPa

    -0.92 kPa

    -1.21 kPa

    a = 2.56 m

    Wind pressures on vertical and horizontal projections of building surfaces; wind direction parallel to transverse walls (end walls).

  • Wind Forces for MWRFS

    Wind

    direction

    3.6 m

    Interior zone

    End zone

    12.8 m

    1.34 kPa

    2.00 kPa

    -1.21 kPa

    -1.73 kPa

    a = 2.56 m

    2.2 m

    -0.92 kPa

    -1.21 kPa

    Wind pressure on vertical and horizontal projections of building surfaces; wind direction perpendicular to transverse walls (end walls).

    o wind Speed = 200 kph (zone 2, p. 2-72)

    o Exposure C (No overhangs)

    o total height of building = 5.8 m

    o eave height = 3.6 m