    Cisco MDS 9000 Family NX-OS Interfaces

    Configuration GuideCisco MDS NX-OS Release 4.2(1) Through 4.2(7)

    July 2010

    Text Part Number: OL-19445-02

    http://www.cisco.com/http://www.cisco.com/
  • 8/11/2019 Cisco MDS 9000 NX-OS Interface Config Guide

    2/204

    Send documentat ion comments to mdsfeedback -doc@c isco .com

    THE SPECIFICATIONS AND INFORMATION REGARDING THE PRODUCTS IN THIS MANUAL ARE SUBJECT TO CHANGE WITHOUT NOTICE. ALL

    STATEMENTS, INFORMATION, AND RECOMMENDATIONS IN THIS MANUAL ARE BELIEVED TO BE ACCURATE BUT ARE PRESENTED WITHOUT

    WARRANTY OF ANY KIND, EXPRESS OR IMPLIED. USERS MUST TAKE FULL RESPONSIBILITY FOR THEIR APPLICATION OF ANY PRODUCTS.

    THE SOFTWARE LICENSE AND LIMITED WARRANTY FOR THE ACCOMPANYING PRODUCT ARE SET FORTH IN THE INFORMATION PACKET THAT

    SHIPPED WITH THE PRODUCT AND ARE INCORPORATED HEREIN BY THIS REFERENCE. IF YOU ARE UNABLE TO LOCATE THE SOFTWARE LICENSE

    OR LIMITED WARRANTY, CONTACT YOUR CISCO REPRESENTATIVE FOR A COPY.

    The Cisco implementation of TCP header compression is an adaptation of a program developed by the University of California, Berkeley (UCB) as part of UCBs public

    domain version of the UNIX operating system. All rights reserved. Copyright 1981, Regents of the University of California.

    NOTWITHSTANDING ANY OTHER WARRANTY HEREIN, ALL DOCUMENT FILES AND SOFTWARE OF THESE SUPPLIERS ARE PROVIDED AS IS WITH

    ALL FAULTS. CISCO AND THE ABOVE-NAMED SUPPLIERS DISCLAIM ALL WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING, WITHOUT

    LIMITATION, THOSE OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT OR ARISING FROM A COURSE OF

    DEALING, USAGE, OR TRADE PRACTICE.

    IN NO EVENT SHALL CISCO OR ITS SUPPLIERS BE LIABLE FOR ANY INDIRECT, SPECIAL, CONSEQUENTIAL, OR INCIDENTAL DAMAGES, INCLUDING,

    WITHOUT LIMITATION, LOST PROFITS OR LOSS OR DAMAGE TO DATA ARISING OUT OF TH E USE OR INABILITY TO USE THIS MANUAL, EVEN IF CISCO

    OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.

    Cisco and the Cisco Logo are trademarks of Cisco Systems, Inc. and/or its affiliates in the U.S. and other countries. A listing of Cisco's trademarks can be found at

    www.cisco.com/go/trademarks . Third party trademarks mentioned are the property of their respective owners. The use of the word partner does not imply a partnership

    relationship between Cisco and any other company. (1005R)

    Any Internet Protocol (IP) addresses and phone numbers used in this document are not intended to be actual addresses and phone numbers. Any examples, command display

    output, network topology diagrams, and other figures included in the document are shown for illustrative purposes only. Any use of actual IP addresses or phone numbers in

    illustrative content is unintentional and coincidental.

    Cisco MDS 9000 Family NX-OS Interfaces Configuration Guide

    2009 Cisco Systems, Inc. All rights reserved.

    http://www.cisco.com/go/trademarkshttp://www.cisco.com/go/trademarks
  • 8/11/2019 Cisco MDS 9000 NX-OS Interface Config Guide

    3/204

    Send documentat ion comments to mdsfeedback -doc@c isco .com

    iii

    Cisco MDS 9000 Family NX-OS Interfaces Configuration Guide

    OL-19445-02, Cisco MDS NX-OS Release 4.2(x)

    C O N T E N T S

    New and Changed Information xi

    Preface xiii

    Audience xiii

    Organization xiii

    Document Conventions xiv

    Related Documentation xv

    Release Notes xv

    Regulatory Compliance and Safety Information xvCompatibility Information xv

    Hardware Installation xv

    Software Installation and Upgrade xv

    Cisco NX-OS xvi

    Cisco Fabric Manager xvi

    Command-Line Interface xvi

    Intelligent Storage Networking Services Configuration Guides xvi

    Troubleshooting and Reference xvii

    Obtaining Documentation and Submitting a Service Request xvii xvii

    C HA P T E R 1 Interfaces Overview 1-1

    Trunks and PortChannels 1-1

    Fibre Channel Port Rate Limiting 1-2

    Extended Credits 1-2

    N Port Virtualization 1-2

    FlexAttach 1-2

    C HA P T E R 2 Configuring Interfaces 2-1

    Fibre Channel Interfaces 2-1

    Generation 1 Interfaces Configuration Guidelines 2-2

    About Interface Modes 2-3

    E Port 2-4

    F Port 2-4

    FL Port 2-4

  • 8/11/2019 Cisco MDS 9000 NX-OS Interface Config Guide

    4/204

    Send documentat ion comments to mdsfeedback -doc@c isco .com

    Contents

    iv

    Cisco MDS 9000 Family NX-OS Interfaces Configuration Guide

    OL-19445-02, Cisco MDS NX-OS Release 4.2(x)

    NP Ports 2-4

    TL Port 2-5

    TE Port 2-5

    TF Port 2-5

    TNP Port 2-6

    SD Port 2-6

    ST Port 2-6

    Fx Port 2-6

    B Port 2-6

    Auto Mode 2-7

    About Interface States 2-7

    Administrative States 2-7

    Operational States 2-7

    Reason Codes 2-7

    Configuring Fibre Channel Interfaces 2-11

    Graceful Shutdown 2-12

    Setting the Interface Administrative State 2-12

    Configuring Interface Modes 2-13

    Configuring System Default Port Mode F 2-13

    Configuring Port Speeds 2-14

    Autosensing 2-15

    About Interface Descriptions 2-15

    Configuring the Interface Description 2-15

    Specifying a Port Owner 2-15

    About Frame Encapsulation 2-16

    Identifying the Beacon LEDs 2-16

    About Speed LEDs 2-17

    About Beacon Mode 2-17

    Configuring Beacon Mode 2-17

    About Bit Error Thresholds 2-18

    Switch Port Attribute Default Values 2-18

    About SFP Transmitter Types 2-19Displaying Interface Information 2-20

    TL Ports for Private Loops 2-28

    About TL Ports 2-28

    About TL Port ALPA Caches 2-30

    Displaying TL Port Information 2-30

    Manually Inserting Entries into ALPA Cache 2-32

    Displaying the ALPA Cache Contents 2-32

    Clearing the ALPA Cache 2-32

  • 8/11/2019 Cisco MDS 9000 NX-OS Interface Config Guide

    5/204

  • 8/11/2019 Cisco MDS 9000 NX-OS Interface Config Guide

    6/204

    Send documentat ion comments to mdsfeedback -doc@c isco .com

    Contents

    vi

    Cisco MDS 9000 Family NX-OS Interfaces Configuration Guide

    OL-19445-02, Cisco MDS NX-OS Release 4.2(x)

    Dynamic Bandwidth Management 3-7

    Out-of-Service Interfaces 3-8

    Combining Generation 1, Generation 2, and Generation 3 Modules 3-8

    Port Indexes 3-9PortChannels 3-11

    Configuring Module Interface Shared Resources 3-14

    Displaying Interface Capabilities 3-14

    Configuration Guidelines for 48-Port, 24-Port, and 4/44-Port 8-Gbps Fibre Channel Switching

    Modules 3-15

    Migrating from Shared Mode to Dedicated Mode 3-16

    Migrating from Dedicated Mode to Shared Mode 3-16

    Configuration Guidelines for 48-Port and 24-Port 4-Gbps Fibre Channel Switching Modules 3-17

    Migrating from Shared Mode to Dedicated Mode 3-17

    Migrating from Dedicated Mode to Shared Mode 3-17

    Configuration Guidelines for 12-Port 4-Gbps Switching Module Interfaces 3-18

    Configuration Guidelines for 4-Port 10-Gbps Switching Module Interfaces 3-18

    Configuring Port Speed 3-19

    Configuring Rate Mode 3-21

    Configuring Oversubscription Ratio Restrictions 3-26

    Disabling Restrictions on Oversubscription Ratios 3-28

    Oversubscription Ratio Restrictions Example 3-29

    Enabling Restrictions on Oversubscription Ratios 3-31

    Configuring Bandwidth Fairness 3-31

    Enabling Bandwidth Fairness 3-32

    Disabling Bandwidth Fairness 3-32

    Upgrade or Downgrade Scenario 3-33

    Taking Interfaces Out of Service 3-33

    Releasing Shared Resources in a Port Group 3-34

    Disabling ACL Adjacency Sharing for System Image Downgrade 3-35

    Displaying SFP Diagnostic Information 3-35

    Example Configurations 3-36

    Configuring a 48-Port 8-Gbps Fibre Channel Switching Module Example 3-36

    Configuring a 24-Port 8-Gbps Fibre Channel Switching Module Example 3-37

    Configuring a 4/44-Port 8-Gbps Fibre Channel Switching Module Example 3-37

    Configuring a 24-Port 4-Gbps Fibre Channel Switching Module Example 3-38

    Configuring a 48-Port 4-Gbps Fibre Channel Switching Module Example 3-39

    Default Settings 3-40

  • 8/11/2019 Cisco MDS 9000 NX-OS Interface Config Guide

    7/204

    Send documentat ion comments to mdsfeedback -doc@c isco .com

    Contents

    vii

    Cisco MDS 9000 Family NX-OS Interfaces Configuration Guide

    OL-19445-02, Cisco MDS NX-OS Release 4.2(x)

    C HA P T E R 4 Configuring Interface Buffers 4-1

    About Buffer-to-Buffer Credits 4-1

    Configuring Buffer-to-Buffer Credits 4-2

    About Performance Buffers 4-2

    Configuring Performance Buffers 4-3

    Buffer Pools 4-3

    BB_Credit Buffers for Switching Modules 4-6

    Configuring Buffer Credits on a Generation 2 or Generation 3 Module 4-6

    48-Port 8-Gbps Fibre Channel Module BB_Credit Buffers 4-7

    24-Port 8-Gbps Fibre Channel Module BB_Credit Buffers 4-8

    4/44-Port 8-Gbps Host-Optimized Fibre Channel Module BB_Credit Buffers 4-9

    48-Port 4-Gbps Fibre Channel Module BB_Credit Buffers 4-10

    24-Port 4-Gbps Fibre Channel Module BB_Credit Buffers 4-1218-Port Fibre Channel/4-Port Gigabit Ethernet Multiservice Module BB_Credit Buffers 4-13

    12-Port 4-Gbps Switching Module BB_Credit Buffers 4-13

    4-Port 10-Gbps Switching Module BB_Credit Buffers 4-15

    BB_Credit Buffers for Fabric Switches 4-16

    Cisco MDS 9134 Fabric Switch BB_Credit Buffers 4-16

    Cisco MDS 9124 Fabric Switch BB_Credit Buffers 4-16

    Cisco MDS 9222i Multiservice Modular Switch BB_Credit Buffers 4-16

    About Extended BB_Credits 4-17

    Extended BB_credits on Generation 1 Switching Modules 4-17Extended BB_credits on Generation 2 and Generation 3 Switching Modules 4-18

    Configuring Extended BB_credits 4-19

    Enabling Buffer-to-Buffer State Change Number 4-19

    To use the BB_SC_N field during PLOGI or FLOGI, follow these steps: 4-20

    .About Receive Data Field Size 4-20

    Configuring Receive Data Field Size 4-20

    Displaying BB_Credit Information 4-21

    C HA P T E R 5 Configuring Trunking 5-1About Trunking 5-1

    Trunking E Ports 5-2

    Trunking F Ports 5-2

    Key Concepts 5-3

    Trunking Guidelines and Restrictions 5-3

    Trunking Misconfiguration Examples 5-4

    Upgrade and Downgrade Restrictions 5-5

  • 8/11/2019 Cisco MDS 9000 NX-OS Interface Config Guide

    8/204

    Send documentat ion comments to mdsfeedback -doc@c isco .com

    Contents

    viii

    Cisco MDS 9000 Family NX-OS Interfaces Configuration Guide

    OL-19445-02, Cisco MDS NX-OS Release 4.2(x)

    Difference Between TE Ports and TF-TNP Ports 5-5

    Enabling the Trunking Protocols 5-7

    About Trunking Protocols 5-7

    Enabling the Cisco Trunking and Channeling Protocols 5-8Enabling the F Port Trunking and Channeling Protocol 5-8

    Configuring Trunk Mode and VSAN List 5-8

    About Trunk Modes 5-8

    Configuring Trunk Mode 5-9

    About Trunk-Allowed VSAN Lists and VF_IDs 5-9

    Configuring an Allowed-Active List of VSANs 5-12

    Example F Port Trunking Configuration 5-12

    Displaying Trunking Information 5-13

    Default Settings 5-14

    C HA P T E R 6 Configuring PortChannels 6-1

    About PortChannels 6-1

    About E PortChannels 6-2

    About F and TF PortChannels 6-3

    About PortChanneling and Trunking 6-3

    About Load Balancing 6-4

    About PortChannel Modes 6-6

    Configuration Guidelines and Restrictions 6-7Generation 1 PortChannel Limitations 6-7

    F and TF PortChannel Restrictions 6-8

    PortChannel Configuration 6-9

    About PortChannel Configuration 6-10

    Creating a PortChannel 6-11

    Configuring the PortChannel Mode 6-11

    About PortChannel Deletion 6-12

    Deleting PortChannels 6-12

    Interfaces in a PortChannel 6-12About Interface Addition to a PortChannel 6-13

    Compatibility Check 6-13

    Suspended and Isolated States 6-13

    Adding an Interface to a PortChannel 6-14

    Forcing an Interface Addition 6-14

    About Interface Deletion from a PortChannel 6-15

    Deleting an Interface from a PortChannel 6-15

    PortChannel Protocols 6-15

  • 8/11/2019 Cisco MDS 9000 NX-OS Interface Config Guide

    9/204

    Send documentat ion comments to mdsfeedback -doc@c isco .com

    Contents

    ix

    Cisco MDS 9000 Family NX-OS Interfaces Configuration Guide

    OL-19445-02, Cisco MDS NX-OS Release 4.2(x)

    About Channel Group Creation 6-16

    About Autocreation 6-18

    Enabling and Configuring Autocreation 6-18

    About Manually Configured Channel Groups 6-19

    Converting to Manually Configured Channel Groups 6-19

    Example F and TF PortChannel Configurations 6-19

    Verifying the PortChannel Configuration 6-21

    Default Settings 6-25

    C HA P T E R 7 Configuring N Port Virtualization 7-1

    About N Port Identifier Virtualization 7-1

    Enabling N Port Identifier Virtualization 7-2

    About N Port Virtualization 7-2

    NPV Mode 7-4

    NP Ports 7-5

    NP Links 7-5

    Internal FLOGI Parameters 7-5

    Default Port Numbers 7-6

    NPV CFS Distribution over IP 7-7

    NPV Traffic Management 7-7

    Auto 7-7

    Traffic Map 7-7Disruptive 7-8

    Multiple VSAN Support 7-8

    NPV Guidelines and Requirements 7-8

    NPV Traffic Management Guidelines 7-9

    Configuring NPV 7-9

    Configuring NPV Traffic Management 7-11

    Configuring List of External Interfaces per Server Interface 7-11

    Enabling or Disabling the Global Policy for Disruptive Load Balancing 7-11

    DPVM Configuration 7-12NPV and Port Security 7-12

    Verifying NPV 7-12

    Verifying NPV Traffic Management 7-14

    C HA P T E R 8 Configuring FlexAttach Virtual pWWN 8-1

    About FlexAttach Virtual pWWN 8-1

    FlexAttach Virtual pWWN Guidelines and Requirements 8-2

  • 8/11/2019 Cisco MDS 9000 NX-OS Interface Config Guide

    10/204

    Send documentat ion comments to mdsfeedback -doc@c isco .com

    Contents

    x

    Cisco MDS 9000 Family NX-OS Interfaces Configuration Guide

    OL-19445-02, Cisco MDS NX-OS Release 4.2(x)

    Configuring FlexAttach Virtual pWWN 8-2

    Enabling FlexAttach Virtual pWWN 8-2

    Automatically Enabling FlexAttach Virtual pWWN 8-2

    Manually Enabling FlexAttach Virtual pWWN 8-3

    Mapping pWWN to Virtual pWWN 8-3

    Verifying FlexAttach Virtual pWWN 8-4

    Verifying the End Device 8-4

    Debugging FlexAttach Virtual pWWN 8-5

    Security Settings for FlexAttach Virtual pWWN 8-5

    FlexAttach Virtual pWWN CFS Distribution 8-6

    Difference Between San Device Virtualization and FlexAttach Port Virtualization 8-6

  • 8/11/2019 Cisco MDS 9000 NX-OS Interface Config Guide

    11/204

    Send documentat ion comments to mdsfeedback -doc@c isco .com

    xi

    Cisco MDS 9000 Family NX-OS Interfaces Configuration Guide

    OL-19445-02, Cisco MDS NX-OS Release 4.2(x)

    New and Changed Information

    As of Cisco MDS NX-OS Release 4.2(1), software configuration information is available in new

    feature-specific configuration guides for the following information:

    System management

    Interfaces

    Fabric

    Quality of service

    Security

    IP services

    High availability and redundancy

    The information in these new guides previously existed in the Cisco MDS 9000 Family CLI

    Configuration Guideand in theCisco MDS 9000 Family Fabric Manager Configuration Guide. Those

    configuration guides remain available on Cisco.com and should be used for all software releases prior

    to MDS NX-OS Release 4.2(1). Each guide addresses the features introduced in or available in a

    particular release. Select and view the configuration guide that pertains to the software installed in yourswitch.

    For a complete list of document titles, see the list of Related Documentation in the Preface.

    To find additional information about Cisco MDS NX-OS Release 4.2(x), see the Cisco MDS 9000 Family

    Release Notes available at the following Cisco Systems website:

    http://www.cisco.com/en/US/products/ps5989/prod_release_notes_list.htm

    About this Guide

    The information in the new Cisco MDS 9000 NX-OS Interfaces Configuration Guidepreviously existed

    in Part 3: Switch Configuration of the Cisco MDS 9000 Family CLI Configuration Guide.

    Table 1lists the New and Changed features for this guide, starting with MDS NX-OS Release 4.2(1).

    http://www.cisco.com/en/US/products/ps5989/prod_release_notes_list.htmlhttp://-/?-http://-/?-http://www.cisco.com/en/US/products/ps5989/prod_release_notes_list.html
  • 8/11/2019 Cisco MDS 9000 NX-OS Interface Config Guide

    12/204

    Send documentat ion comments to mdsfeedback -doc@c isco .com

    xii

    Cisco MDS 9000 Family NX-OS Interfaces Configuration Guide

    OL-19445-02, Cisco MDS NX-OS Release 4.2(x)

    New and Changed Information

    Table 1-1 New and Changed Features for Cisco MDS NX-OS Release 4.2(x)

    Feature New and Change Topics

    ChangedinRelease Where Documented

    Slow Drain Device

    Detection and Congestion

    Avoidance

    Added information about configuring stuck frame

    timeout value, no-credit timeout value, credit loss

    recovery threshold and action, and average credit

    non-available duration threshold and action.

    4.2(7) Chapter 2, Configuring

    Interfaces

    Port Group Monitor Added information about configuring policies

    and monitoring port groups.

    4.2(1) Chapter 2, Configuring

    Interfaces

    Port Guard Added port guard configuration guidelines for

    multiple types of port failure causes.

    4.2(1) Chapter 2, Configuring

    Interfaces

  • 8/11/2019 Cisco MDS 9000 NX-OS Interface Config Guide

    13/204

    Send documentat ion comments to mdsfeedback -doc@c isco .com

    xiii

    Cisco MDS 9000 Family NX-OS Interfaces Configuration Guide

    OL-19445-02, Cisco MDS NX-OS Release 4.2(x)

    Preface

    This preface describes the audience, organization, and conventions of the Cisco MDS 9000 Family

    NX-OS Interfaces Configuration Guide . It also provides information on how to obtain related

    documentation.

    AudienceThis guide is for experienced network administrators who are responsible for configuring and

    maintaining the Cisco MDS 9000 Family of multilayer directors and fabric switches.

    OrganizationThe Cisco MDS 9000 Family NX-OS Interfaces Configuration Guideis organized as follows:

    Chapter Title DescriptionChapter 1 Interfaces Overview Provides an overview of all the features in this

    guide.

    Chapter 2 Configuring Interfaces Explains Generation 1 and Generation 2

    module port and operational state concepts in

    Cisco MDS 9000 Family switches and provides

    details on configuring ports and interfaces.

    Chapter 3 Configuring Fibre Channel Interfaces Explains configuration concepts for Fibre

    Channel module ports and interfaces.

    Chapter 4 Configuring Interface Buffers Explains configuration concepts for Interface

    Buffers.

    Chapter 5 Configuring Trunking Explains TE ports and trunking concepts.

    Chapter 6 Configuring Por tChannels Explains PortChannels and load balancing

    concepts and provides details on configuring

    PortChannels, adding ports to PortChannels,

    and deleting ports from PortChannels.

  • 8/11/2019 Cisco MDS 9000 NX-OS Interface Config Guide

    14/204

    Send documentat ion comments to mdsfeedback -doc@c isco .com

    xiv

    Cisco MDS 9000 Family NX-OS Interfaces Configuration Guide

    OL-19445-02, Cisco MDS NX-OS Release 4.2(x)

    Preface

    Document ConventionsCommand descriptions use these conventions:

    Screen examples use these conventions:

    This document uses the following conventions:

    Note Means readertake note. Notes contain helpful suggestions or references to material not covered in the

    manual.

    Caution Means reader be careful. In this si tuation, you might do something that could result in equipment

    damage or loss of data.

    Chapter 7 Configuring N Port Virtual ization Provides an overview of N Port Virtualization

    and includes quidelines and requirements for

    configuring and verifying NPV.

    Chapter 8 Configuring FlexAttach VirtualpWWN

    FlexAttach virtual pWWN feature facilitatesserver and configuration management. In a

    SAN environment, the server installation or

    replacement, requires interaction and

    coordination among the SAN and server

    administrators.

    Chapter Title Description

    boldface font Commands and keywords are in boldface.

    italic font Arguments for which you supply values are in italics.

    [ ] Elements in square brackets are optional.

    [ x | y | z ] Optional alternative keywords are grouped in brackets and separated by

    vertical bars.

    screen font Terminal sessions and information the switch displays are in screen font.

    boldface screen font Information you must enter is in boldface screen font.

    italic screen font Arguments for which you supply values are in italic screen font.

    < > Nonprinting characters, such as passwords, are in angle brackets.

    [ ] Default responses to system prompts are in square brackets.

    !, # An exclamation point (!) or a pound sign (#) at the beginning of a line of code

    indicates a comment line.

  • 8/11/2019 Cisco MDS 9000 NX-OS Interface Config Guide

    15/204

    Send documentat ion comments to mdsfeedback -doc@c isco .com

    xv

    Cisco MDS 9000 Family NX-OS Interfaces Configuration Guide

    OL-19445-02, Cisco MDS NX-OS Release 4.2(x)

    Preface

    Related DocumentationThe documentation set for the Cisco MDS 9000 Family includes the following documents. To find a

    document online, use the Cisco MDS NX-OS Documentation Locator at:

    http://www.cisco.com/en/US/docs/storage/san_switches/mds9000/roadmaps/doclocater.htm

    Release Notes

    Cisco MDS 9000 Family Release Notes for Cisco MDS NX-OS Releases

    Cisco MDS 9000 Family Release Notes for MDS SAN-OS Releases

    Cisco MDS 9000 Family Release Notes for Storage Services Interface Images

    Cisco MDS 9000 Family Release Notes for Cisco MDS 9000 EPLD Images

    Release Notes for Cisco MDS 9000 Family Fabric Manager

    Regulatory Compliance and Safety Information

    Regulatory Compliance and Safety Information for the Cisco MDS 9000 Family

    Compatibility Information

    Cisco Data Center Interoperability Support Matrix

    Cisco MDS 9000 NX-OS Hardware and Software Compatibility Information and Feature Lists

    Cisco MDS NX-OS Release Compatibility Matrix for Storage Service Interface Images

    Cisco MDS 9000Family Switch-to-Switch Interoperability Configuration Guide

    Cisco MDS NX-OS Release Compatibility Matrix for IBM SAN Volume Controller Software for

    Cisco MDS 9000

    Cisco MDS SAN-OS Release Compatibility Matrix for VERITAS Storage Foundation for Networks

    Software

    Hardware Installation

    Cisco MDS 9500 Series Hardware Installation Guide

    Cisco MDS 9200 Series Hardware Installation Guide

    Cisco MDS 9100 Series Hardware Installation Guide

    Cisco MDS 9124 and Cisco MDS 9134 Multilayer Fabric Switch Quick Start Guide

    Software Installation and Upgrade

    Cisco MDS 9000 NX-OS Release 4.1(x) and SAN-OS 3(x) Software Upgrade and Downgrade Guide

    Cisco MDS 9000 Family Storage Services Interface Image Install and Upgrade Guide

  • 8/11/2019 Cisco MDS 9000 NX-OS Interface Config Guide

    16/204

    Send documentat ion comments to mdsfeedback -doc@c isco .com

    xvi

    Cisco MDS 9000 Family NX-OS Interfaces Configuration Guide

    OL-19445-02, Cisco MDS NX-OS Release 4.2(x)

    Preface

    Cisco MDS 9000 Family Storage Services Module Software Installation and Upgrade Guide

    Cisco NX-OS

    Cisco MDS 9000 Family NX-OS Fundamentals Configuration Guide

    Cisco MDS 9000 Family NX-OS Licensing Guide

    Cisco MDS 9000 Family NX-OS System Management Configuration Guide

    Cisco MDS 9000 Family NX-OS Interfaces Configuration Guide

    Cisco MDS 9000 Family NX-OS Fabric Configuration Guide

    Cisco MDS 9000 Family NX-OS Quality of Service Configuration Guide

    Cisco MDS 9000 Family NX-OS Security Configuration Guide

    Cisco MDS 9000 Family NX-OS IP Services Configuration Guide

    Cisco MDS 9000 Family NX-OS Intelligent Storage Services Configuration Guide

    Cisco MDS 9000 Family NX-OS High Availability and Redundancy Configuration Guide

    Cisco MDS 9000 Family NX-OS Inter-VSAN Routing Configuration Guide

    Cisco Fabric Manager

    Cisco Fabric Manager Fundamentals Configuration Guide

    Cisco Fabric Manager System Management Configuration Guide

    Cisco Fabric Manager Interfaces Configuration Guide

    Cisco Fabric Manager Fabric Configuration Guide

    Cisco Fabric Manager Quality of Service Configuration Guide

    Cisco Fabric Manager Security Configuration Guide

    Cisco Fabric Manager IP Services Configuration Guide

    Cisco Fabric Manager Intelligent Storage Services Configuration Guide

    Cisco Fabric Manager High Availability and Redundancy Configuration Guide

    Cisco Fabric Manager Inter-VSAN Routing Configuration Guide

    Cisco Fabric Manager Online Help

    Cisco Fabric Manager Web Services Online Help

    Command-Line Interface

    Cisco MDS 9000 FamilyCommand Reference

    Intelligent Storage Networking Services Configuration Guides

    Cisco MDS 9000 Family I/O Accelerator Configuration Guide

    Cisco MDS 9000 Family SANTap Deployment Guide

  • 8/11/2019 Cisco MDS 9000 NX-OS Interface Config Guide

    17/204

    Send documentat ion comments to mdsfeedback -doc@c isco .com

    xvii

    Cisco MDS 9000 Family NX-OS Interfaces Configuration Guide

    OL-19445-02, Cisco MDS NX-OS Release 4.2(x)

    Preface

    Cisco MDS 9000 Family Data Mobility Manager Configuration Guide

    Cisco MDS 9000 Family Storage Media Encryption Configuration Guide

    Cisco MDS 9000 Family Secure Erase Configuration Guide

    Cisco MDS 9000 Family Cookbook for Cisco MDS SAN-OS

    Troubleshooting and Reference

    Cisco NX-OS System Messages Reference

    Cisco MDS 9000 Family NX-OS Troubleshooting Guide

    Cisco MDS 9000 Family NX-OS MIB Quick Reference

    Cisco MDS 9000 Family NX-OS SMI-S Programming Reference

    Cisco MDS 9000 Family Fabric Manager Server Database Schema

    Obtaining Documentation and Submitting a Service RequestFor information on obtaining documentation, submitting a service request, and gathering additional

    information, see the monthly Whats New in Cisco Product Documentation, which also lists all new and

    revised Cisco technical documentation, at:

    http://www.cisco.com/en/US/docs/general/whatsnew/whatsnew.html

    Subscribe to the Whats New in Cisco Product Documentation as an RSS feed and set content to be

    delivered directly to your desktop using a reader application. The RSS feeds are a free service. Cisco currently

    supports RSS Version 2.0.

    http://www.cisco.com/en/US/docs/general/whatsnew/whatsnew.htmlhttp://www.cisco.com/en/US/docs/general/whatsnew/whatsnew.html
  • 8/11/2019 Cisco MDS 9000 NX-OS Interface Config Guide

    18/204

    Send documentat ion comments to mdsfeedback -doc@c isco .com

    xviii

    Cisco MDS 9000 Family NX-OS Interfaces Configuration Guide

    OL-19445-02, Cisco MDS NX-OS Release 4.2(x)

    Preface

  • 8/11/2019 Cisco MDS 9000 NX-OS Interface Config Guide

    19/204

    C H A P T E R

    Send documentat ion comments to mdsfeedback -doc@c isco .com

    1-1

    Cisco MDS 9000 Family NX-OS Interfaces Configuration Guide

    OL-19445-02, Cisco MDS NX-OS Release 4.2(x)

    1Interfaces Overview

    This chapter describes the basic interfaces that are used with Fabric Manager. These interfaces include

    Gigabit Ethernet interfaces, Fiber Channel interfaces, virtual interfaces on Nexus hardware, buffer

    credits, management interfaces, VSAN interfaces, shared interface resources, trunking, PortChanneling,

    N port virtualization (NPV), and FlexAttach virtual pWWN.

    This chapter includes the following topics:

    Trunks and PortChannels, page 1-1

    Fibre Channel Port Rate Limiting, page 1-2

    Extended Credits, page 1-2

    N Port Virtualization, page 1-2

    FlexAttach, page 1-2

    Trunks and PortChannelsTrunking, also known as VSAN t runking, is a feature specific to switches in the Cisco MDS 9000

    Family. Trunking enables interconnect ports to transmit and receive frames in more than one VSAN, over

    the same physical link. Trunking is supported on E ports and F ports.

    PortChannels aggregate multiple physical ISLs into one logical link with higher bandwidth and port

    resiliency for both Fibre Channel and FICON traffic. With this feature, up to 16 expansion ports

    (E-ports) or trunking E-ports (TE-ports) can be bundled into a PortChannel. ISL ports can reside on any

    switching module, and they do not need a designated master port. If a port or a switching module fails,

    the PortChannel continues to function properly wi thout requiring fabric reconfiguration.

    Cisco NX-OS software uses a protocol to exchange PortChannel configuration information between

    adjacent switches to simplify PortChannel management, including misconfiguration detection and

    autocreation of PortChannels among compatible ISLs. In the autoconfigure mode, ISLs with compatible

    parameters automatically form channel groups; no manual intervention is required.

    PortChannels load balance Fibre Channel traffic using a hash of source FC-ID and destination FC-ID,

    and optionally the exchange ID. Load balancing using PortChannels is performed over both Fibre

    Channel and FCIP links. Cisco NX-OS software also can be configured to load balance across multiple

    same-cost FSPF routes.

  • 8/11/2019 Cisco MDS 9000 NX-OS Interface Config Guide

    20/204

    Send documentat ion comments to mdsfeedback -doc@c isco .com

    1-2

    Cisco MDS 9000 Family NX-OS Interfaces Configuration Guide

    OL-19445-02, Cisco MDS NX-OS Release 4.2(x)

    Chapter 1 Interfaces Overview

    Fibre Channel Port Rate Limiting

    Fibre Channel Port Rate LimitingThe Fibre Channel port rate-limiting feature for the Cisco MDS 9100 Series controls the amount of

    bandwidth available to individual Fibre Channel ports within groups of four host-optimized ports.

    Limiting bandwidth on one or more Fibre Channel ports allows the other ports in the group to receive a

    greater share of the available bandwidth under high-utilization conditions. Port rate limiting is also

    beneficial for throttling WAN traffic at the source to help eliminate excessive buffering in Fibre Channel

    and IP data network devices.

    Extended CreditsFull line-rate Fibre Channel ports provide at least 255 buffer credits standard. Adding credits lengthens

    distances for Fibre Channel SAN extension. Using extended credits, up to 4095 buffer credits from a

    pool of more than 6000 buffer credits for a module can be allocated to ports as needed to greatly extend

    the distance for Fibre Channel SANs.

    N Port VirtualizationCisco NX-OS software supports industry-standard N port identifier virtualization (NPIV), which allows

    multiple N port fabric logins concurrently on a single physical Fibre Channel link. HBAs that support

    NPIV can help improve SAN security by enabling zoning and port security to be configured

    independently for each virtual machine (OS partition) on a host. In addition to being useful for server

    connections, NPIV is beneficial for connectivity between core and edge SAN switches.

    N port virtualizer (NPV) is a complementary feature that reduces the number of Fibre Channel domain

    IDs in core-edge SANs. Cisco MDS 9000 family fabric switches operating in the NPV mode do not join

    a fabric; they only pass traffic between core switch links and end devices, which eliminates the domain

    IDs for these switches. NPIV is used by edge switches in the NPV mode to log in to multiple end devices

    that share a link to the core switch. This feature is available only for Cisco MDS Blade Switch Series,

    the Cisco MDS 9124 Multilayer Fabric Switch, and the Cisco MDS 9134 Multilayer Fabric Switch.

    FlexAttachCisco NX-OS supports the FlexAttach feature. One of the main problems in a SAN environment is the

    time and effort required to install and replace servers. The process involves both SAN and server

    administrators, and the interaction and coordination between them can make the process time

    consuming. To alleviate the need for interaction between SAN and server administrators, the SAN

    configuration should not be changed when a new server is installed or an existing server is replaced.

    FlexAttach addresses these problems, reducing configuration changes and the time and coordination

    required by SAN and server administrators when installing and replacing servers. This feature is

    available only for Cisco MDS 9000 Blade Switch Series, the Cisco MDS 9124, and the Cisco MDS 9134

    when NPV mode is enabled.

  • 8/11/2019 Cisco MDS 9000 NX-OS Interface Config Guide

    21/204

    Send documentat ion comments to mdsfeedback -doc@c isco .com

    1-3

    Cisco MDS 9000 Family NX-OS Interfaces Configuration Guide

    OL-19445-02, Cisco MDS NX-OS Release 4.2(x)

    Chapter 1 Interfaces Overview

    FlexAttach

  • 8/11/2019 Cisco MDS 9000 NX-OS Interface Config Guide

    22/204

    Send documentat ion comments to mdsfeedback -doc@c isco .com

    1-4

    Cisco MDS 9000 Family NX-OS Interfaces Configuration Guide

    OL-19445-02, Cisco MDS NX-OS Release 4.2(x)

    Chapter 1 Interfaces Overview

    FlexAttach

  • 8/11/2019 Cisco MDS 9000 NX-OS Interface Config Guide

    23/204

    C H A P T E R

    Send documentat ion comments to mdsfeedback -doc@c isco .com

    2-1

    Cisco MDS 9000 Family NX-OS Interfaces Configuration Guide

    OL-19445-02, Cisco MDS NX-OS Release 4.2(x)

    2Configuring Interfaces

    The main function of a switch is to relay frames from one data link to another. To relay the frames, the

    characteristics of the interfaces through which the frames are received and sent must be defined. The

    configured interfaces can be Fibre Channel interfaces, Gigabit Ethernet interfaces, the management

    interface (mgmt0), or VSAN interfaces.

    This chapter describes the basic interface configuration to get your switch up and running. It includes

    the following sections:

    Fibre Channel Interfaces, page 2-1

    TL Ports for Private Loops, page 2-28

    Configuring Port Guard, page 2-32

    Configuring Port Monitor, page 2-34

    Configuring Port Group Monitor, page 2-40

    Configuring Slow Drain Device Detection and Congestion Avoidance, page 2-44

    Management Interfaces, page 2-47

    VSAN Interfaces, page 2-49

    Default Settings, page 2-50

    For more information on configuring mgmt0 interfaces, refer to the Cisco MDS 9000 Family NX-OS

    Fundamentals Configuration Guideand Cisco MDS 9000 Family NX-OS IP Services Configuration

    Guide.

    See the Cisco MDS 9000 Family NX-OS IP Services Configuration Guidefor more information on

    configuring Gigabit Ethernet interfaces.

    Tip Before you begin configuring the switch, ensure that the modules in the chassis are functioning as

    designed. To verify the status of a module at any time, enter the show modulecommand in EXEC mode

    (for information about verifying the module status, refer to the Cisco NX-OS Fundamentals

    Configuration Guide).

    Fibre Channel InterfacesThis section describes Fibre Channel interface characteristics, including (but not limited to) modes,

    frame encapsulation, states, SFPs, and speeds.

    This section includes the following topics:

  • 8/11/2019 Cisco MDS 9000 NX-OS Interface Config Guide

    24/204

    Send documentat ion comments to mdsfeedback -doc@c isco .com

    2-2

    Cisco MDS 9000 Family NX-OS Interfaces Configuration Guide

    OL-19445-02, Cisco MDS NX-OS Release 4.2(x)

    Chapter 2 Configuring Interfaces

    Fibre Channel Interfaces

    Generation 1 Interfaces Configuration Guidelines, page 2-2

    About Interface Modes, page 2-3

    About Interface States, page 2-7

    Configuring Fibre Channel Interfaces, page 2-11

    Graceful Shutdown, page 2-12

    Configuring Interface Modes, page 2-13

    Configuring Port Speeds, page 2-14

    About Interface Descriptions, page 2-15

    Configuring the Interface Description, page 2-15

    Specifying a Port Owner, page 2-15

    About Frame Encapsulation, page 2-16

    Identifying the Beacon LEDs, page 2-16

    About Beacon Mode, page 2-17

    About Bit Error Thresholds, page 2-18

    Switch Port Attribute Default Values, page 2-18

    About SFP Transmitter Types, page 2-19

    Displaying Interface Information, page 2-20

    Generation 1 Interfaces Configuration Guidelines

    The Generation 1 interfaces configuration guidelines apply to the following hardware:

    The 32-port, 2-Gbps or 1-Gbps switching module interfaces.

    The Cisco MDS 9140 and 9120 switch interfaces.

    Note Due to the hardware design of the MDS 9134 switch, we do not support interface

    out-of-service action on either of its two 10-Gigabit ports. This is because no internal port

    hardware resource is released when an out-of-service action is performed on these

    10-Gigabit ports.

    When configuring these host-optimized ports, the following port mode guidelines apply:

    You can configure only the first port in each 4-port group (for example, the first port in ports 1-4,

    the fifth port in ports 5-8, and so on) as an E port. If the first port in the group is configured as an E

    port, the other three ports in each group (ports 2-4, 6-8, and so on) are not usable and remainshutdown.

    If you execute the write erasecommand on a 32-port switching module, and then copy a saved

    configuration to the switch from a text file that contains the no system default switchport

    shutdowncommand, you need to copy the text file to the switch again for the E ports to come up

    without manual configuration.

    If any of the other three ports are enabled, you cannot configure the first port as an E port. The other

    three ports continue to remain enabled.

  • 8/11/2019 Cisco MDS 9000 NX-OS Interface Config Guide

    25/204

    Send documentat ion comments to mdsfeedback -doc@c isco .com

    2-3

    Cisco MDS 9000 Family NX-OS Interfaces Configuration Guide

    OL-19445-02, Cisco MDS NX-OS Release 4.2(x)

    Chapter 2 Configuring Interfaces

    Fibre Channel Interfaces

    The auto mode is not a llowed in a 32-port switching module or the host-optimized ports in the Cisco

    9100 Series (16 host-optimized ports in the Cisco MDS 9120 switch and 32 host-optimized ports in

    the Cisco MDS 9140 switch).

    The default port mode is Fx (Fx negotiates to F or FL) for 32-port switching modules.

    The 32-port switching module does not support FICON.

    Note We recommend that you configure your E ports on a 16-port switching module. If you must configure

    an E port on a 32-port host-optimized switching module, the other three ports in that 4-port group cannot

    be used.

    Note In the Cisco MDS 9100 Series, the groups of ports that are located on the left and outlined in white are

    full line rate. The other ports are host-optimized. Each group of 4 host-optimized ports have the same

    features as for the 32-port switching module.

    About Interface Modes

    Each physical Fibre Channel interface in a switch may operate in one of several port modes: E port, F

    port, FL port, TL port, TE port, SD port, S T p o r t , a n d B port (see Figure 2-1). Besides these modes, each

    interface may be configured in auto or Fx port modes. These two modes determine the port type during

    interface initialization.

    Figure 2-1 Cisco MDS 9000 Family Switch Port Modes

    Note Interfaces are created in VSAN 1 by default. See the Cisco MDS 9000 Family NX-OS Fabric

    Configuration Guide.

    Each interface has an associated administrative configuration and an operational status:

    N port

    F port

    Publicloop

    loop

    E port E portFL port

    NL port NL port

    NL port NL port

    p

    TL port

    ISL link

    79528

    Private

  • 8/11/2019 Cisco MDS 9000 NX-OS Interface Config Guide

    26/204

    Send documentat ion comments to mdsfeedback -doc@c isco .com

    2-4

    Cisco MDS 9000 Family NX-OS Interfaces Configuration Guide

    OL-19445-02, Cisco MDS NX-OS Release 4.2(x)

    Chapter 2 Configuring Interfaces

    Fibre Channel Interfaces

    The administrative configuration does not change unless you modify it. This configuration has

    various attributes that you can configure in administrative mode.

    The operational status represents the current status of a specified attribute like the interface speed.

    This status cannot be changed and is read-only. Some values may not be valid when the interface is

    down (for example, the operational speed).

    Note When a module is removed and replaced with the same type of module, the configuration is retained. If

    a different type of module is inserted, then the original configuration is no longer retained.

    Each interface is briefly described in the sections that follow.

    E Port

    In expansion port (E port) mode, an interface functions as a fabric expansion port. This port may be

    connected to another E port to create an Inter-Switch Link (ISL) between two switches. E ports carry

    frames between switches for configuration and fabric management. They serve as a conduit between

    switches for frames destined to remote N ports and NL ports. E ports support class 2, class 3, and class

    F service.

    An E port connected to another switch may also be configured to form a PortChannel (see Chapter 6,

    Configuring PortChannels).

    Note We recommend that you configure E ports on 16-port modules. If you must configure an E port on a

    32-port oversubscribed module, then you can only use the first port in a group of four ports (for example,

    ports 1 through 4, 5 through 8, and so forth). The other three ports cannot be used.

    F Port

    In fabric port (F port) mode, an interface functions as a fabric port. This port may be connected to a

    peripheral device (host or disk) operating as an N port. An F port can be attached to only one N port. F

    ports support class 2 and class 3 service.

    FL Port

    In fabric loop port (FL port) mode, an interface functions as a fabric loop port. This port may be

    connected to one or more NL ports (including FL ports in other switches) to form a public arbitrated

    loop. If more than one FL port is detected on the arbitrated loop during initialization, only one FL port

    becomes operational and the other FL ports enter nonparticipating mode. FL ports support class 2 and

    class 3 service.

    Note FL port mode is not supported on 4-port 10-Gbps switching module interfaces.

    NP Ports

    An NP port is a port on a device that is in NPV mode and connected to the core switch via an F port. NP

    ports function like N ports except that in addition to providing N port operations, they also function as

    proxies for multiple, physical N ports.

  • 8/11/2019 Cisco MDS 9000 NX-OS Interface Config Guide

    27/204

    Send documentat ion comments to mdsfeedback -doc@c isco .com

    2-5

    Cisco MDS 9000 Family NX-OS Interfaces Configuration Guide

    OL-19445-02, Cisco MDS NX-OS Release 4.2(x)

    Chapter 2 Configuring Interfaces

    Fibre Channel Interfaces

    For more details about NP ports and NPV, see Chapter 7, Configuring N Port Virtualization.

    TL Port

    In translative loop port (TL port) mode, an interface functions as a translative loop port. It may be

    connected to one or more pr ivate loop devices (NL ports). TL ports are specific to Cisco MDS 9000

    Family switches and have similar properties as FL ports. TL ports enable communication between a

    private loop device and one of the following devices:

    A device attached to any switch on the fabric

    A device on a public loop anywhere in the fabric

    A device on a different private loop anywhere in the fabric

    A device on the same private loop

    TL ports support class 2 and class 3 services.

    Private loop devices refer to legacy devices that reside on arbitrated loops. These devices are not aware

    of a switch fabric because they only communicate with devices on the same physical loop (see the

    About TL Port ALPA Caches section on page 2-30).

    Tip We recommend configuring devices attached to TL ports in zones that have up to 64 zone members.

    Note TL port mode is not supported on Generation 2 switching module interfaces.

    TE Port

    In trunking E port (TE port) mode, an interface functions as a trunking expansion port. It may be

    connected to another TE port to create an extended ISL (EISL) between two switches. TE ports are

    specific to Cisco MDS 9000 Family switches. They expand the functionality of E ports to support the

    following:

    VSAN trunking

    Transport quality of service (QoS) parameters

    Fibre Channel trace (fctrace) feature

    In TE port mode, all frames are transmitted in EISL frame format, which contains VSAN information.

    Interconnected switches use the VSAN ID to multiplex traffic from one or more VSANs across the same

    physical link. This feature is referred to as trunking in the Cisco MDS 9000 Family (see Chapter 5,

    Configuring Trunking). TE ports support class 2, class 3, and class F service.

    TF Port

    In trunking F port (TF port) mode, an interface functions as a t runking expansion port. It may be

    connected to another trunked N port (TN port) or trunked NP port (TNP port) to create a link between a

    core switch and an NPV switch or an HBA to carry tagged frames. TF ports are specific to Cisco MDS

    9000 Family switches. They expand the functionality of F ports to support VSAN trunking.

  • 8/11/2019 Cisco MDS 9000 NX-OS Interface Config Guide

    28/204

    Send documentat ion comments to mdsfeedback -doc@c isco .com

    2-6

    Cisco MDS 9000 Family NX-OS Interfaces Configuration Guide

    OL-19445-02, Cisco MDS NX-OS Release 4.2(x)

    Chapter 2 Configuring Interfaces

    Fibre Channel Interfaces

    In TF port mode, all frames are transmitted in EISL frame format, which contains VSAN information.

    Interconnected switches use the VSAN ID to multiplex traffic from one or more VSANs across the same

    physical link. This feature is referred to as trunking in the Cisco MDS 9000 Family (see Chapter 5,

    Configuring Trunking). TF ports support class 2, class 3, and class F service.

    TNP Port

    In trunking NP port (TNP port) mode, an interface functions as a trunking expansion port. It may be

    connected to a trunked F port (TF port) to create a link to a core NPIV switch from an NPV switch to

    carry tagged frames.

    SD Port

    In SPAN destination port (SD port) mode, an interface functions as a switched port analyzer (SPAN).

    The SPAN feature is specific to switches in the Cisco MDS 9000 Family. It monitors network traffic that

    passes though a Fibre Channel interface. This monitoring is done using a standard Fibre Channel

    analyzer (or a similar switch probe) that is attached to an SD port. SD ports do not receive frames, they

    only transmit a copy of the source traffic. The SPAN feature is nonintrusive and does not affect switching

    of network traffic for any SPAN source ports (see the Cisco MDS 9000 Family NX-OS System

    Management Configuration Guide).

    ST Port

    In the SPAN tunnel port (ST port) mode, an interface functions as an entry point port in the source switch

    for the RSPAN Fibre Channel tunnel. The ST port mode and the remote SPAN (RSPAN) feature are

    specific to switches in the Cisco MDS 9000 Family. When configured in ST port mode, the interface

    cannot be attached to any device, and thus cannot be used for normal Fibre Channel traffic (see the Cisco

    MDS 9000 Family NX-OS System Management Configuration Guide).

    Note ST port mode is not supported on the Cisco MDS 9124 Fabric Switch, the Cisco Fabric Switch for HP

    c-Class BladeSystem, and the Cisco Fabric Switch for IBM BladeCenter.

    Fx Port

    Interfaces configured as Fx ports can operate in either F port or FL port mode. The Fx port mode is

    determined during interface initialization depending on the attached N port or NL port. This

    administrative configuration disallows interfaces to operate in any other modefor example, preventing

    an interface to connect to another switch.

    B Port

    While E ports typically interconnect Fibre Channel switches, some SAN extender devices, such as the

    Cisco PA-FC-1G Fibre Channel port adapter, implement a bridge port (B port) model to connect

    geographically dispersed fabrics. This model uses B ports as described in the T11 Standard FC-BB-2.

    If an FCIP peer is a SAN extender device that only supports Fibre Channel B ports, you need to enable

    the B port mode for the FCIP link. When a B port is enabled, the E port functionality is also enabled and

    they coexist. If the B port is disabled, the E port functionality remains enabled (see the Cisco MDS 9000

    Family NX-OS IP Services Configuration Guide).

  • 8/11/2019 Cisco MDS 9000 NX-OS Interface Config Guide

    29/204

    Send documentat ion comments to mdsfeedback -doc@c isco .com

    2-7

    Cisco MDS 9000 Family NX-OS Interfaces Configuration Guide

    OL-19445-02, Cisco MDS NX-OS Release 4.2(x)

    Chapter 2 Configuring Interfaces

    Fibre Channel Interfaces

    Auto Mode

    Interfaces configured in auto mode can operate in one of the following modes: F port, FL port, E port,

    TE port, or TF port. The port mode is determined during interface initialization. For example, if the

    interface is connected to a node (host or disk), it operates in F port or FL port mode depending on the N

    port or NL port mode. If the interface is attached to a third-party switch, it operates in E port mode. Ifthe interface is attached to another switch in the Cisco MDS 9000 Family, it may become operational in

    TE port mode (see Chapter 5, Configuring Trunking).

    TL ports and SD ports are not determined during initialization and are administratively configured.

    Note Fibre Channel interfaces on Storage Services Modules (SSMs) cannot be configured in auto mode.

    About Interface States

    The interface state depends on the administrative configuration of the interface and the dynamic state of

    the physical link.

    Administrative States

    The administrative state refers to the administrative configuration of the interface as described in

    Table 2-1.

    Operational States

    The operational state indicates the current operational state of the interface as described in Table 2-2.

    Reason Codes

    Reason codes are dependent on the operational state of the interface as described in Table 2-3.

    Table 2-1 Administrative States

    Administrative State Description

    Up Interface is enabled.

    Down Interface is disabled. If you adminis tratively disable an interface by shuttingdown that interface, the physical link layer state change is ignored.

    Table 2-2 Operational States

    Operational State Description

    Up Interface is transmitting or receiving traffic as desired. To be in this state, an

    interface must be administratively up, the interface link layer state must be up, andthe interface initialization must be completed.

    Down Interface cannot transmit or receive (data) traffic.

    Trunking Interface is operational in TE or TF mode.

  • 8/11/2019 Cisco MDS 9000 NX-OS Interface Config Guide

    30/204

    Send documentat ion comments to mdsfeedback -doc@c isco .com

    2-8

    Cisco MDS 9000 Family NX-OS Interfaces Configuration Guide

    OL-19445-02, Cisco MDS NX-OS Release 4.2(x)

    Chapter 2 Configuring Interfaces

    Fibre Channel Interfaces

    Note Only some of the reason codes are listed in Table 2-4.

    If the administrative state is up and the operational state is down, the reason code differs based on the

    nonoperational reason code as described in Table 2-4.

    Table 2-3 Reason Codes for Interface States

    AdministrativeConfiguration

    OperationalStatus Reason Code

    Up Up None.Down Down Administratively downIf you administratively configure an interface

    as down, you disable the interface. No traffic is received or transmitted.

    Up Down See Table 2-4.

  • 8/11/2019 Cisco MDS 9000 NX-OS Interface Config Guide

    31/204

    Send documentat ion comments to mdsfeedback -doc@c isco .com

    2-9

    Cisco MDS 9000 Family NX-OS Interfaces Configuration Guide

    OL-19445-02, Cisco MDS NX-OS Release 4.2(x)

    Chapter 2 Configuring Interfaces

    Fibre Channel Interfaces

    Table 2-4 Reason Codes for Nonoperational States

    Reason Code (long version) DescriptionApplicableModes

    Link failure or not connected The physical layer link is not operational. AllSFP not present The small form-factor pluggable (SFP) hardware is not

    plugged in.

    Initializing The physical layer link is operational and the protocol

    initialization is in progress.

    Reconfigure fabric in progress The fabric is currently being reconfigured.

    Offline The Cisco NX-OS software waits for the specified

    R_A_TOV time before retrying initialization.

    Inactive The interface VSAN is deleted or is in a suspended

    state.

    To make the interface operational, assign that port to a

    configured and active VSAN.

    Hardware failure A hardware failure is detected.

    Error disabled Error conditions require administrative attention.

    Interfaces may be error-disabled for various reasons.

    For example:

    Configuration failure.

    Incompatible buffer-to-buffer credit configuration.

    To make the interface operational, you must first fix the

    error conditions causing this state; and next,

    administratively shut down or enable the interface.

    FC redirect failure A port is isolated because a Fibre Channel redirect is

    unable to program routes.

    No port activation license

    available

    A port is not active because it does not have a port

    license.

    SDM failure A port is isolated because SDM is unable to program

    routes.

  • 8/11/2019 Cisco MDS 9000 NX-OS Interface Config Guide

    32/204

    Send documentat ion comments to mdsfeedback -doc@c isco .com

    2-10

    Cisco MDS 9000 Family NX-OS Interfaces Configuration Guide

    OL-19445-02, Cisco MDS NX-OS Release 4.2(x)

    Chapter 2 Configuring Interfaces

    Fibre Channel Interfaces

    Isolation due to ELP failure The port negotiation failed. Only E ports

    and TE portsIsolation due to ESC failure The port negotiation failed.

    Isolation due to domain

    overlap

    The Fibre Channel domains (fcdomain) overlap.

    Isolation due to domain ID

    assignment failure

    The assigned domain ID is not valid.

    Isolation due to the other side

    of the link E port isolated

    The E port at the other end of the link is isolated.

    Isolation due to invalid fabric

    reconfiguration

    The port is isolated due to fabric reconfiguration.

    Isolation due to domain

    manager disabled

    The fcdomain feature is disabled.

    Isolation due to zone merge

    failure

    The zone merge operation failed.

    Isolation due to VSAN

    mismatch

    The VSANs at both ends of an ISL are different.

    Nonparticipating FL ports cannot participate in loop operations. It may

    happen if more than one FL port exists in the same

    loop, in which case all but one FL port in that loop

    automatically enters nonparticipating mode.

    Only FL

    ports and TL

    ports

    PortChannel administratively

    down

    The interfaces belonging to the PortChannel are down. Only

    PortChannel

    interfacesSuspended due to incompatible

    speed

    The interfaces belonging to the PortChannel have

    incompatible speeds.

    Suspended due to incompatible

    mode

    The interfaces belonging to the PortChannel have

    incompatible modes.

    Suspended due to incompatible

    remote switch WWN

    An improper connection is detected. All interfaces in a

    PortChannel must be connected to the same pair of

    switches.

    Table 2-4 Reason Codes for Nonoperational States (continued)

    Reason Code (long version) DescriptionApplicableModes

  • 8/11/2019 Cisco MDS 9000 NX-OS Interface Config Guide

    33/204

    Send documentat ion comments to mdsfeedback -doc@c isco .com

    2-11

    Cisco MDS 9000 Family NX-OS Interfaces Configuration Guide

    OL-19445-02, Cisco MDS NX-OS Release 4.2(x)

    Chapter 2 Configuring Interfaces

    Fibre Channel Interfaces

    Configuring Fibre Channel Interfaces

    To configure a Fibre Channel interface, follow these steps:

    To configure a range of interfaces, follow these steps:

    For the Cisco Fabric Switch for HP c-Class BladeSystem and the Cisco Fabric Switch for IBM

    BladeCenter, you can configure a range of interfaces among internal ports or external ports, but you

    cannot mix both interface types within the same range. For example, bay 1-10, bay 12 or ext 0, ext

    15-18 are valid ranges, but bay 1-5, ext 15-17 is not.

    Command Purpose

    Step 1 switch# config t Enters configuration mode.

    Step 2 switch(config)# interface fc1/1switch(config-if)#

    Selects a Fibre Channel interface and enters interface

    configuration submode.

    Note When a Fibre Channel interface is configured, it is

    automatically assigned a unique world wide name

    (WWN). If the interfaces operational state is up, it is

    also assigned a Fibre Channel ID (FC ID).

    Command Purpose

    Step 1 switch# config t Enters configuration mode.

    Step 2 switch(config)# interface fc1/1 - 4 , fc2/1 - 3switch(config-if)#

    Selects the range of Fibre Channel interfaces

    and enters interface configuration submode3.

    Note In this command, provide a space

    before and after the comma.

  • 8/11/2019 Cisco MDS 9000 NX-OS Interface Config Guide

    34/204

    Send documentat ion comments to mdsfeedback -doc@c isco .com

    2-12

    Cisco MDS 9000 Family NX-OS Interfaces Configuration Guide

    OL-19445-02, Cisco MDS NX-OS Release 4.2(x)

    Chapter 2 Configuring Interfaces

    Fibre Channel Interfaces

    Graceful Shutdown

    Interfaces on a port are shut down by default (unless you modified the initial configuration).

    The Cisco NX-OS software implicitly performs a graceful shutdown in response to either of the

    following actions for interfaces operating in the E port mode:

    If you shut down an interface.

    If a Cisco NX-OS software application executes a port shutdown as part of its function.

    A graceful shutdown ensures that no frames are lost when the interface is shutting down. When a

    shutdown is triggered either by you or the Cisco NX-OS software, the switches connected to the

    shutdown link coordinate with each other to ensure that all frames in the ports are safely sent through

    the link before shutting down. This enhancement reduces the chance of frame loss.

    A graceful shutdown is not possible in the following situations:

    If you physically remove the port from the switch.

    If in-order delivery (IOD) is enabled (for information about IOD, refer to the Cisco MDS 9000

    Family NX-OS Fabric Configuration Guide). If the Min_LS_interval interval is higher than 10 seconds (for information about FSPF global

    configuration, refer to the Cisco MDS 9000 Family NX-OS Fabric Configuration Guide ).

    Note This feature is only triggered if both switches at either end of this E port interface are MDS switches and

    are running Cisco SAN-OS Release 2.0(1b) or later, or MDS NX-OS Release 4.1(1a) or later.

    Setting the Interface Administrative State

    To gracefully shut down an interface, follow these steps:

    To enable traffic flow, follow these steps:

    Command Purpose

    Step 1 switch# config t Enters configuration mode.

    Step 2 switch(config)# interface fc1/1 Selects a Fibre Channel interface and enters interface

    configuration submode.

    Step 3 switch(config-if)# shutdown Gracefully shuts down the interface and administratively

    disables traffic flow (default).

    Command Purpose

    Step 1 switch# config t Enters configuration mode.

    Step 2 switch(config)# interface fc1/1 Selects a Fibre Channel interface and enters interface

    configuration submode.

    Step 3 switch(config-if)# no shutdown Enables traffic flow to administratively allow traffic when

    the noprefix is used (provided the operational state is up).

  • 8/11/2019 Cisco MDS 9000 NX-OS Interface Config Guide

    35/204

    Send documentat ion comments to mdsfeedback -doc@c isco .com

    2-13

    Cisco MDS 9000 Family NX-OS Interfaces Configuration Guide

    OL-19445-02, Cisco MDS NX-OS Release 4.2(x)

    Chapter 2 Configuring Interfaces

    Fibre Channel Interfaces

    Configuring Interface Modes

    To configure the interface mode, follow these steps:

    Configuring System Default Port Mode F

    The system default switchport mode F command sets the administrative mode of all Fibre Channel

    ports to mode F, while avoiding traffic disruption caused by the formation of unwanted Inter-Switch

    Links (ISLs). This command is part of the setup utility that runs during bootup after a write eraseorreload. It can also be executed from the command line in configuration mode. This command changes

    the configuration of the following ports to administrative mode F:

    All ports that are down and that are not out-of-service.

    All F ports that are up, whose operational mode is F, and whose administrative mode is not F.

    This command does not affect the configuration of the following ports:

    All user-configured ports, even if they are down.

    All non-F ports that are up; however, if non-F ports are down, this command changes the

    administrative mode of those ports.

    Example 2-1shows the command in the setup utility, and Example 2-2shows the command from the

    command line.

    Example 2-1 Setup Utility

    Configure default switchport mode F (yes/no) [n]:y

    Example 2-2 Command Line

    switch(config)# system default switchport mode F

    Command Purpose

    Step 1 switch# config t Enters configuration mode.

    Step 2 switch(config)# interfacefc1/1switch(config-if)#

    Selects a Fibre Channel interface and enters interface

    configuration submode.

    Step 3 switch(config-if)# switchport mode Fswitch(config-if)#

    Configures the administrative mode of the port. You

    can set the operational state to auto, E, F, FL, Fx, TL,

    NP, or SD port mode.

    Note Fx ports refers to an F port or an FL port (host

    connection only), but not E ports.

    switch(config-if)# switchport mode autoswitch(config-if)#

    Configures the interface mode to auto-negotiate an E,

    F, FL, or TE port mode (not TL or SD port modes) of

    operation.

    Note TL ports and SD ports cannot be configured

    automatically. They must be administratively

    configured.

    Note You cannot configure Fibre Channel interfaces

    on SSMs in auto mode.

  • 8/11/2019 Cisco MDS 9000 NX-OS Interface Config Guide

    36/204

    Send documentat ion comments to mdsfeedback -doc@c isco .com

    2-14

    Cisco MDS 9000 Family NX-OS Interfaces Configuration Guide

    OL-19445-02, Cisco MDS NX-OS Release 4.2(x)

    Chapter 2 Configuring Interfaces

    Fibre Channel Interfaces

    Note To ensure that ports that are part of ISLs do not get changed to port mode F, configure the ports in port

    mode E, rather than in Auto mode.

    Note When the command is executed from the command line, switch operation remains graceful. No ports are

    flapped.

    To set the administrative mode of Fibre Channel ports to mode F in the CLI, follow these steps:

    Note For detailed information about the switch setup utility see the Cisco MDS 9000 Family NX-OS

    Fundamentals Configuration Guide.

    Configuring Port Speeds

    By default, the port administrative speed for an interface is automatically calculated by the switch.

    Caution Changing the port administrative speed is a disruptive operation.

    To configure the port speed of the interface, follow these steps:

    Command Purpose

    Step 1 switch# config t Enters configuration mode.

    Step 2 switch(config)# system defaultswitchport mode F

    Sets the administrative mode of Fibre Channel ports to

    mode F (if applicable).

    switch(config)# no system default

    switchport mode FSets the administrative mode of Fibre Channel ports to

    the default (unless user configured).

    Command Purpose

    Step 1 switch# config t Enters configuration mode.

    Step 2 switch(config)# interface fc 1/1 Selects the mgmt0 interface and enters interface

    configuration mode.

    Step 3 switch(config-if)# switchport speed 1000 Configures the port speed of the interface to 1000

    Mbps.

    The number indicates the speed in megabits per

    second (Mbps). You can set the speed to 1000(for

    1-Gbps interfaces), 2000(for 2-Gbps interfaces),

    4000(for 4-Gbps interfaces), 8000(for 8-Gbps

    interfaces), or auto(default).

    switch(config-if)# no switchport speed Reverts the factory default (auto) administrative

    speed of the interface.

  • 8/11/2019 Cisco MDS 9000 NX-OS Interface Config Guide

    37/204

    Send documentat ion comments to mdsfeedback -doc@c isco .com

    2-15

    Cisco MDS 9000 Family NX-OS Interfaces Configuration Guide

    OL-19445-02, Cisco MDS NX-OS Release 4.2(x)

    Chapter 2 Configuring Interfaces

    Fibre Channel Interfaces

    For internal ports on the Cisco Fabric Switch for HP c_Class BladeSystem and Cisco Fabric Switch for

    IBM BladeCenter, a port speed of 1 Gbps is not supported. Auto-negotiation is supported between 2

    Gbps and 4 Gbps only. Also, if the BladeCenter is a T chassis, then port speeds are fixed at 2 Gbps and

    auto-negotiation is not enabled.

    Autosensing

    Autosensing speed is enabled on all 4-Gbps and 8-Gbps switching module interfaces by default. This

    configuration enables the interfaces to operate at speeds of 1 Gbps, 2 Gbps, or 4 Gbps on the 4-Gbps

    switching modules, and 8 Gbps on the 8-Gbps switching modules. When autosensing is enabled for an

    interface operating in dedicated rate mode, 4 Gbps of bandwidth is reserved, even if the port negotiates

    at an operating speed of 1 Gbps or 2 Gbps.

    To avoid wasting unused bandwidth on 48-port and 24-port 4-Gbps and 8-Gbps Fibre Channel switching

    modules, you can specify that only 2 Gbps of required bandwidth be reserved, not the default of 4 Gbps

    or 8 Gbps. This feature shares the unused bandwidth within the port group provided that it does not

    exceed the rate limit configuration for the port. You can also use this feature for shared rate ports that

    are configured for autosensing.

    Tip When migrating a host that supports up to 2-Gbps traffic (that is, not 4 Gbps with autosensing

    capabilities) to the 4-Gbps switching modules, use autosensing with a maximum bandwidth of 2 Gbps.

    When migrating a host that supports up to 4-Gbps traffic (that is, not 8 Gbps with autosensing

    capabilities) to the 8-Gbps switching modules, use autosensing with a maximum bandwidth of 4 Gbps.

    About Interface Descriptions

    Interface descriptions enable you to identify the traffic or the use for that interface. The interface

    description can be any alphanumeric string.

    Configuring the Interface Description

    To configure a description for an interface, follow these steps:

    Specifying a Port Owner

    Using the port owner feature, you can specify the owner of a port and the purpose for which a port is

    used so that the other administrators are informed.

    Command Purpose

    Step 1 switch# config t Enters configuration mode.

    Step 2 switch(config)# interfacefc1/1switch(config-if)#

    Selects a Fibre Channel interface and

    enters interface configuration submode.

    Step 3 switch(config-if)# switchport description cisco-HBA2 Configures the description of the

    interface. The string can be up to 80characters long.

    switch(config-if)# no switchport description Clears the description of the interface.

  • 8/11/2019 Cisco MDS 9000 NX-OS Interface Config Guide

    38/204

    Send documentat ion comments to mdsfeedback -doc@c isco .com

    2-16

    Cisco MDS 9000 Family NX-OS Interfaces Configuration Guide

    OL-19445-02, Cisco MDS NX-OS Release 4.2(x)

    Chapter 2 Configuring Interfaces

    Fibre Channel Interfaces

    To specify or remove the port owner, follow these steps:

    Note The port guard and port owner features are available for all ports regardless of the operational mode.

    To display the owner description specified for a port, use the following commands:

    switch# show running interface fcmodule-number/interface-number

    switch# show port internal info interface fcmodule-number/interface-number

    About Frame Encapsulation

    The switchport encap eislcommand only applies to SD port interfaces. This command determines the

    frame format for all frames transmitted by the interface in SD port mode. If the encapsulation is set to

    EISL, all outgoing frames are transmitted in the EISL frame format, regardless of the SPAN sources.

    The switchport encap eislcommand is disabled by default. If you enable encapsulation, all outgoing

    frames are encapsulated, and you will see a new line (Encapsulation is eisl) in the show interface

    SD_port_interfacecommand output (see the Cisco MDS 9000 Family NX-OS System Management

    Configuration Guide).

    Identifying the Beacon LEDs

    Figure 2-2displays the status, link, and speed LEDs in a 16-port switching module.

    Figure 2-2 Cisco MDS 9000 Family Switch Interface Modes

    Command Purpose

    Step 1 switch# config t Enters configuration mode.

    Step 2 switch(config)# interface fc1/1 Selects the port interface.

    Step 3 switch(config)# switchport owner description The description can include name of the owner

    and the purpose for which the port is used. The

    description can be up to 80 characters long.

    switch(config)# no switchport owner Removes (default) the port owner description.

    1 Status LED1

    1. Se e th e Cisco MDS 9000 Family NX-OS Fundamentals Configuration Guide.

    3 Link LEDs1and speed LEDs2

    2 1/2-Gbps Fibre Channel port group3 4 Asset tag4

    77686

    2

    1 43

  • 8/11/2019 Cisco MDS 9000 NX-OS Interface Config Guide

    39/204

    Send documentat ion comments to mdsfeedback -doc@c isco .com

    2-17

    Cisco MDS 9000 Family NX-OS Interfaces Configuration Guide

    OL-19445-02, Cisco MDS NX-OS Release 4.2(x)

    Chapter 2 Configuring Interfaces

    Fibre Channel Interfaces

    About Speed LEDsEach port has one link LED on the left and one speed LED on the right.

    The speed LED displays the speed of the port interface:

    OffThe interface attached to that port is functioning at 1000 Mbps.

    On (solid green)The interface attached to that port is functioning at 2000 Mbps (for 2 Gbps

    interfaces).

    The speed LED also displays if the beacon mode is enabled or disabled:

    Off or solid greenBeacon mode is disabled.

    Flashing greenThe beacon mode is enabled. The LED flashes at one-second intervals.

    Note Generation 2 and Generation 3 modules and fabric switches do not have speed LEDs.

    About Beacon Mode

    By default, the beacon mode is disabled on all switches. The beacon mode is indicated by a flashing

    green light that helps you identify the physical location of the specified interface.

    Configuring the beacon mode has no effect on the operation of the interface.

    Configuring Beacon ModeTo enable beacon mode for a specified interface or range of interfaces, follow these steps:

    Note The flashing green light turns on automatically when an external loopback is detected that causes the

    interfaces to be isolated. The flashing green light overrides the beacon mode configuration. The state of

    the LED is restored to reflect the beacon mode configuration after the external loopback is removed.

    2. See the About Speed LEDs section on page 2-17.

    3. See the Generation 1 Interfaces Configuration Guidelines section on page 2-2.

    4. Refer to the Cisco MDS 9000 Family hardware installation guide for your platform.

    Command Purpose

    Step 1 switch# config tswitch(config)#

    Enters configuration mode.

    Step 2 switch(config)# interfacefc1/1switch(config-if)#

    Selects a Fibre Channel interface and enters

    interface configuration submode.

    Step 3 switch(config-if)# switchport beacon Enables the beacon mode for the interface.

    switch(config-if)# noswitchport beacon Disables the beacon mode for the interface.

  • 8/11/2019 Cisco MDS 9000 NX-OS Interface Config Guide

    40/204

    Send documentat ion comments to mdsfeedback -doc@c isco .com

    2-18

    Cisco MDS 9000 Family NX-OS Interfaces Configuration Guide

    OL-19445-02, Cisco MDS NX-OS Release 4.2(x)

    Chapter 2 Configuring Interfaces

    Fibre Channel Interfaces

    About Bit Error Thresholds

    The bit error rate threshold is used by the switch to detect an increased error rate before performance

    degradation seriously affects traffic.

    The bit errors can occur for the following reasons:

    Faulty or bad cable.

    Faulty or bad GBIC or SFP.

    GBIC or SFP is specified to operate at 1 Gbps but is used at 2 Gbps.

    GBIC or SFP is specified to operate at 2 Gbps but is used at 4 Gbps.

    Short haul cable is used for long haul or long haul cable is used for short haul.

    Momentary sync loss.

    Loose cable connection at one or both ends.

    Improper GBIC or SFP connection at one or both ends.

    A bit error rate threshold is detected when 15 error bursts occur in a 5-minute period. By default, theswitch disables the interface when the threshold is reached. You can enter a shutdown andno shutdown

    command sequence to reenable the interface.

    You can configure the switch to not disable an interface when the threshold is crossed. By default, the

    threshold disables the interface.

    To disable the bit error threshold for an interface, follow these steps:

    Note Regardless of the setting of the switchport ignore bit-errorscommand, the switch generates a syslog

    message when bit-error threshold events are detected.

    Switch Port Attribute Default ValuesYou can configure attribute default values for various switch port attributes. These attributes will be

    applied globally to all future switch port configurations, even if you do not individually specify them at

    that time.

    Command Purpose

    Step 1 switch# config t Enters configuration mode.

    Step 2 switch(config)# interfacefc1/1switch(config-if)#

    Selects a Fibre Channel interface and enters

    interface configuration submode.

    Step 3 switch(config-if)# switchport ignorebit-errors

    Prevents the detection of bit error threshold

    events from disabling the interface.

    switch(config-if)# no switchport ignorebit-errors

    Prevents the detection of bit error threshold

    events from enabling the interface.

  • 8/11/2019 Cisco MDS 9000 NX-OS Interface Config Guide

    41/204

    Send documentat ion comments to mdsfeedback -doc@c isco .com

    2-19

    Cisco MDS 9000 Family NX-OS Interfaces Configuration Guide

    OL-19445-02, Cisco MDS NX-OS Release 4.2(x)

    Chapter 2 Configuring Interfaces

    Fibre Channel Interfaces

    To configure switch port attributes, follow these steps:

    About SFP Transmitter Types

    The small form-factor pluggable (SFP) hardware transmitters are identified by their acronyms when

    displayed in the show interface brief command. If the related SFP has a Cisco-assigned extended ID,

    then the show interfaceand show interface briefcommands display the ID instead of the transmitter

    type. The show interface transceivercommand and the show interface fcs lot/porttransceiver

    command display both values for Cisco-supported SFPs. Table 2-5defines the acronyms used in the

    command output (see the Displaying Interface Information section on page 2-20).

    Command Purpose

    Step 1 switch# config t Enters configuration mode.

    Step 2 switch(config)# no system default

    switchport shutdownswitch(config)#

    Configures the default setting for administrative state of an

    interface as Up. (The factory default setting is Down).

    Tip This command is applicable only to interfaces for

    which no user configuration exists for the

    administrative state.

    switch(config)# system default

    switchport shutdownswitch(config)#

    Configures the default setting for administrative state of an

    interface as Down. This is the factory default setting.

    Tip This command is applicable only to interfaces for

    which no user configuration exists for the

    administrative state.

    switch(config)# system defaultswitchport trunk mode auto

    switch(config)#

    Configures the default setting for administrative trunk mode

    state of an interface as Auto.

    Note The default setting is trunk mode on.

    Table 2-5 SFP Transmitter Acronym Definitions

    Definition Acronym

    Standard transmitters defined in the GBIC specifications

    short wave laser swl

    long wave laser lwl

    long wave laser cost reduced lwcr

    electrical elec

    Extended transmitters assigned to Cisco-supported SFPs

    CWDM-1470 c1470

    CWDM-1490 c1490

    CWDM-1510 c1510

    CWDM-1530 c1530

    CWDM-1550 c1550

    CWDM-1570 c1570

    CWDM-1590 c1590

    CWDM-1610 c1610

  • 8/11/2019 Cisco MDS 9000 NX-OS Interface Config Guide

    42/204

    Send documentat ion comments to mdsfeedback -doc@c isco .com

    2-20

    Cisco MDS 9000 Family NX-OS Interfaces Configuration Guide

    OL-19445-02, Cisco MDS NX-OS Release 4.2(x)

    Chapter 2 Configuring Interfaces

    Fibre Channel Interfaces

    Displaying Interface Information

    The show interface command is invoked from the EXEC mode and displays the interface

    configurations. Without any arguments, this command displays the information for al l the configured

    interfaces in the switch. See Examples 2-3to 2-10.

    Example 2-3 Displays All Interfaces

    switch# show interfacefc1/1 is up Hardware is Fibre Channel, SFP is short wave laser

    Port WWN is 20:0b:00:05:30:00:8d:de Admin port mode is F

    Port mode is F, FCID is 0x610000 Port vsan is 2 Speed is 2 Gbps

    Transmit B2B Credit is 3 Receive B2B Credit is 16 Receive data field Size is 2112

    Beacon is turned off 5 minutes input rate 0 bits/sec, 0 bytes/sec, 0 frames/sec 5 minutes output rate 0 bits/sec, 0 bytes/sec, 0 frames/sec

    134 frames input, 8468 bytes 0 discards, 0 errors 0 CRC, 0 unknown class 0 too long, 0 too short 154 frames output, 46072 bytes 0 discards, 0 errors 1 input OLS, 1 LRR, 0 NOS, 0 loop inits

    1 output OLS, 0 LRR, 1 NOS, 0 loop inits 16 receive B2B credit remaining

    3 transmit B2B credit remaining.. . .fc1/9 is trunking

    Hardware is Fibre Channel, SFP is long wave laser cost reduced Port WWN is 20:09:00:05:30:00:97:9e Peer port WWN is 20:0b:00:0b:5f:a3:cc:00

    Admin port mode is E, trunk mode is on Port mode is TE Port vsan is 100 Speed is 2 Gbps Transmit B2B Credit is 255 Receive B2B Credit is 255 Receive data field Size is 2112

    Beacon is turned off Trunk vsans (admin allowed and active) (1,100,3000)

    Trunk vsans (up) (1,100,3000) Trunk vsans (isolated) () Trunk vsans (initializing) ()

    5 minutes input rate 280 bits/sec, 35 bytes/sec, 0 frames/sec 5 minutes output rate 176 bits/sec, 22 bytes/sec, 0 frames/sec 4609939 frames input, 8149405708 bytes

    0 discards, 0 errors 0 CRC, 0 unknown class 0 too long, 0 too short 4638491 frames output, 7264731728 bytes 0 discards, 0 errors 3 input OLS, 9 LRR, 1 NOS, 0 loop inits 9 output OLS, 7 LRR, 1 NOS, 0 loop inits

    16 receive B2B credit remaining 3 transmit B2B credit remaining.

    . . .

  • 8/11/2019 Cisco MDS 9000 NX-OS Interface Config Guide

    43/204

    Send documentat ion comments to mdsfeedback -doc@c isco .com

    2-21

    Cisco MDS 9000 Family NX-OS Interfaces Configuration Guide

    OL-19445-02, Cisco MDS NX-OS Release 4.2(x)

    Chapter 2 Configuring Interfaces

    Fibre Channel Interfaces

    fc1/13 is up Hardware is Fibre Channel, SFP is short wave laser Port WWN is 20:0d:00:05:30:00:97:9e

    Admin port mode is auto, trunk mode is on Port mode is F, FCID is 0x650100

    Port vsan is 100

    Speed is 2 Gbps Transmit B2B Credit is 3 Receive B2B Credit is 16 Receive data field Size is 2112 Beacon is turned off 5 minutes input rate 0 bits/sec, 0 bytes/sec, 0 frames/sec

    5 minutes output rate 0 bits/sec, 0 bytes/sec, 0 frames/sec 8696 frames input, 3227212 bytes

    0 discards, 0 errors 0 CRC, 0 unknown class 0 too long, 0 too short 16799 frames output, 6782444 bytes

    0 discards, 0 errors 0 input OLS, 0 LRR, 0 NOS, 0 loop inits

    1 output OLS, 1 LRR, 0 NOS, 1 loop inits

    16 receive B2B credit remaining 3 transmit B2B credit remaining.. . .sup-fc0 is up Hardware is Fibre Channel Speed is 1 Gbps

    139597 packets input, 13852970 bytes 0 multicast frames, 0 compressed

    0 input errors, 0 frame, 0 overrun 0 fifo 139516 packets output, 16759004 bytes, 0 underruns 0 output errors, 0 collisions, 0 fifo 0 carrier errors

    You can also specify arguments (a range of interfaces or multiple, specified interfaces) to display

    interface information. You can specify a range of interfaces by issuing a command with the following

    example format:

    interfacefc1/1-5,fc2/5-7

    Note The spaces are required before and after the dash ( -) and before and after the comma (,).

    Example 2-4 Displays Multiple, Specified Interfaces

    switch# show interface fc3/13 , fc3/16

    fc3/13 is up Hardware is Fibre Channel, SFP is short wave laser

    Port WWN is 20:8d:00:05:30:00:97:9e Admin port mode is FX

    Port mode is F, FCID is 0x7b0300 Port vsan is 1 Speed is 2 Gbps Transmit B2B Credit is 3 Receive B2B Credit is 12

    Receive data field Size is 2112 Beacon is turned off

    5 minutes input rate 0 bits/sec, 0 bytes/sec, 0 frames/sec 5 minutes output rate 0 bits/sec, 0 bytes/sec, 0 frames/sec 1856 frames input, 116632 bytes 0 discards, 0 errors

    0 CRC, 0 unknown class 0 too long, 0 too short

  • 8/11/2019 Cisco MDS 9000 NX-OS Interface Config Guide

    44/204

    Send documentat ion comments to mdsfeedback -doc@c isco .com

    2-22

    Cisco MDS 9000 Family NX-OS Interfaces Configuration Guide

    OL-19445-02, Cisco MDS NX-OS Release 4.2(x)

    Chapter 2 Configuring Interfaces

    Fibre Channel Interfaces

    1886 frames output, 887712 bytes 0 discards, 0 errors 0 input OLS, 0 LRR, 0 NOS, 1 loop inits

    1 output OLS, 1 LRR, 0 NOS, 1 loop inits 16 receive B2B credit remaining

    3 transmit B2B credit remaining.

    fc3/16 is up Hardware is Fibre Channel, SFP is short wave laser Port WWN is 20:90:00:05:30:00:97:9e Admin port mode is FX Port mode is F, FCID is 0x7d0100

    Port vsan is 3000 Speed is 2 Gbps

    Transmit B2B Credit is 3 Receive B2B Credit is 12 Receive data field Size is 2112 Beacon is turned off

    5 minutes input rate 504 bits/sec, 63 bytes/sec, 0 frames/sec 5 minutes output rate 520 bits/sec, 65 bytes/sec, 0 frames/sec

    47050 frames input, 10311824 bytes

    0 discards, 0 errors 0 CRC, 0 unknown class 0 too long, 0 too short 62659 frames output, 10676988 bytes 0 discards, 0 errors 0 input OLS, 0 LRR, 0 NOS, 0 loop inits

    1 output OLS, 1 LRR, 0 NOS, 1 loop inits 16 receive B2B credit remaining

    3 transmit B2B credit remaining.

    Example 2-5 Displays a Specific Interface

    switch# show interface fc2/2fc2/2 is trunking Port description is Trunk to Core-4 Hardware is Fibre Channel, SFP is short wave laser Port WWN is 20:42:00:05:30:00:97:9e Peer port WWN is 20:cc:00:05:30:00:50:9e

    Admin port mode is E, trunk mode is on Port mode is TE

    Port vsan is 1 Speed is 2 Gbps Transmit B2B Credit is 255 Receive B2B Credit is 255

    Receive data field Size is 2112 Beacon is turned off

    Belongs to port-channel 2 Trunk vsans (admin allowed and active) (1,100,3000) Trunk vsans (up) (1)

    Trunk vsans (isolated) (100,3000) Trunk vsans (initializing) () 5 minutes input rate 0 bits/sec, 0 bytes/sec, 0 frames/sec 5 minutes output rate 32 bits/sec, 4 bytes/sec, 0 frames/sec

    2214834 frames input, 98673588 bytes 0 discards, 0 errors

    0 CRC, 0 unknown class 0 too long, 0 too short 2262415 frames output, 343158368 bytes 0 discards, 0 errors

    1 input OLS, 1 LRR, 1 NOS, 0 loop inits 2 output OLS, 1 LRR, 0 NOS, 0 loop inits

    16 receive B2B credit remaining

  • 8/11/2019 Cisco MDS 9000 NX-OS Interface Config Guide

    45/204

    Send documentat ion comments to mdsfeedback -doc@c isco .com

    2-23

    Cisco MDS 9000 Family NX-OS Interfaces Configuration Guide

    OL-19445-02, Cisco MDS NX-OS Release 4.2(x)

    Chapter 2 Configuring Interfaces

    Fibre Channel Interfaces

    3 transmit B2B credit remaining.

    Example 2-6 Displays Port Description

    switch# show interface description-------------------------------------------------------------------------------

    Interface Description-------------------------------------------------------------------------------

    fc3/1 test intestfc3/2 --fc3/3 --fc3/4 TE portfc3/5 --fc3/6 --fc3/10 Next hop switch 5

    fc3/11 --fc3/12 --

    fc3/16 ---------------------------------------------------------------------------------Interface Description-------------------------------------------------------------------------------

    port-channel 1 --port-channel 5 --port-channel 6 --

    Example 2-7 Displays Interface Information in a Brief Format

    switch# show interface b