PROJECT : PAGE : CLIENT : DESIGN BY : JOB NO. : DATE : REVIEW BY : Circular Column Design Based on ACI 318-14 INPUT DATA & DESIGN SUMMARY CONCRETE STRENGTH = 5 ksi, (34 MPa) REBAR YIELD STRESS = 60 ksi, (414 MPa) SECTION SIZE D = 20 in, (508 mm) FACTORED AXIAL LOAD = 300 kips, (1334 kN) FACTORED MAGNIFIED MOMENT = 140 ft-kips, (190 kN-m) FACTORED SHEAR LOAD = 20 kips, (89 kN) COLUMN VERT. REINFORCEMENT 8 # 6 LATERAL REINF. OPTION (0=Spirals, 1=Ties) 1 Ties LATERAL REINFORCEMENT # 4 @ 12 in. (305 mm), o.c. THE COLUMN DESIGN IS ADEQUATE. ANALYSIS AT AXIAL LOAD ONLY 796 0 AT MAXIMUM LOAD 796 57 AT 0 % TENSION 584 122 AT 25 % TENSION 481 143 AT 50 % TENSION 395 153 272 156 AT BALANCED CONDITION 267 157 38 203 AT FLEXURE ONLY 0 189 CHECK FLEXURAL & AXIAL CAPACITY 796.34 kips., (at max axial load, ACI 318-14 22.4) where 0.65 (ACI 318-14 21.2) > [Satisfactory] F = 0.8 314 3.52 = 0.656 (ACI 318-14 21.2) where 10.4 in 0.0021 0.003 d = 17.6 in, (ACI 20.6) D = 20.0 in Cover = 1.5 in, (ACI 318 20.6.1) 155 300 kips > 140 ft-kips [Satisfactory] = 0.08 (ACI 318-14 10.6) = 0.011 = 0.01 (ACI 318-14 10.6) [Satisfactory] (ACI 318-11 22.5) > [Satisfactory] where 0.75 (ACI 318-11 21.2) 60 ksi d x 17.6 182.7 0.40 25.8 35.3 46 = 12 (ACI 318-14 25.7) = 12 in = 1 [Satisfactory] fc' fy Pu Mu Vu f Pn (k) f Pn (k) f Mn (ft-k) AT e t = 0.002 f Mn (ft-k) AT e t = 0.005 f Pmax =F f [ 0.85 fc' (Ag - Ast) + fy Ast] = f = Pu Ag = in 2 Ast = in 2 f = 0.75 + ( et - 0.002 ) (50), for Spiral 0.65 + ( et - 0.002 ) (250 / 3), for Tie Cb = d ec / (ec + es et = ec = f Mn = ft-kips @ Pu = Mu = rmax rprovd rmin CHECK SHEAR CAPACITY (ACI 318-14 10 & 22.5) f Vn = f (Vs + Vc) Vu f = fy = A0 Av Vc = 2 (fc') 0.5 A0 Vs = MIN (d fy Av / s , 4Vc) f Vn smax sprovd smin 0 50 100 150 200 250 0 100 200 300 400 500 600 700 800 900 e e ' ' 2 ' ' 2 0.85 , 57 , 29000 m ax 0.85 2 , 0 0.85 , , , C C C C C S f or ksi f E E c s o Ec c c for f c o f o o for f c o for E s s s t f for f s t y e e e e e e e e e e e e e e e = = = = =