................................................................................................................................... 176 Line manager - Laboratory
................................................................................................................................... 207 Main interface Lab
......................................................................................................................................................... 22Lab status 7.2
......................................................................................................................................................... 23Measures and events 7.3
.................................................................................................................................................. 26What is freefield ?7.5.3
........................................................................................................................................... 29Create new group
........................................................................................................................................... 30Login for new group
........................................................................................................................................... 30Open group
........................................................................................................................................... 38Statistics of statistic
......................................................................................................................................................... 64Open or create database 9.1
......................................................................................................................................................... 65Configure a database 9.2
Part I: InterfaceThe main control panel is the first interface displayed when you launch CIM software. It containsglobal functions to manage your production, configure the software and read recorded data. Thesefunctions are displayed according to the access level of the current user. Thus the basicproduction functions are available for the operators but advanced configuration functions areavailable only for supervisors.
See password topic for more information about user access level.
M ain control panel
It can be accessible from other panels by click on the following icon:
M ain control panel button
5
Part I: Interface
Manual version : 5.3.0
Notification manager
Notification manager1
Cim notification window
This interface appears when CIM software needs to notify information or problem. The message isdisplayed with the date and time when the problem has been encountered.The user can simply close the window or acknowledge the message. If non acknowledgedmessage exist the window will appear indefinitely until the user valid the message. You candeactivate this automatic popup in preferences panel.To acknowledge the message click on valid button, then the following window will appears.
To valid the message make left click on red or orange icon, check green symbol indicates that themessage was acknowledged.All the messages are stored even if CIM instance was closed. When the log file becomes too big,the file is stored in Log folder and the messages contained in logged file not appear anymore.
Acquit all warning or error.
7
Part I: Interface
Manual version : 5.3.0
Key protection
Key protection2
Key protection button
The following interface appears to manage the protection dongle:
Key protection panel
Select update file: this button display "select file window". Choose the file sent by CERSA toupdate the key software.
Main controls: return to main controls window.
Owner: short name of the customer.Key version: key version for protected software. If a new paid software version exist, you need toupdate the key to benefit of the full features.Key serial number: internal serial number.Key software name: Name for protected software.Key production connexions: maximum number of production connexion. Above this number, noconnexion can be added. The demo mode allows to connect one instrument, performance andfunctionnality of CIM are limited. Key labs connexions: maximum number of lab connexion. Above this number, no connexion canbe added.The demo mode allows to connect one instrument, performance and functionnality ofCIMLab are limited. Key toolbox permission: indicate if toolbox can be connected to CIM software.Key configuration: indicate if the key configuration has been properly loaded.
To benefit the full production features, you must own a license and dongle. Contact CERSA-MCIsales service.
If you use CIM without dongle the software will run in light mode. The software will have thefollowing limitations:
X axis is locked to current mode with only 10 minutes display.Automatic data logging is disabled.Database report and product specifications are disabled.
CIMLab in freeware mode:
If you use CIMLab without dongle the software will run in light mode. The software will have thefollowing limitations:
Only one acquisition is displayed.Graph of statistics trend and table containing the statistics of statistics are not available.Database logging and group management are not allowed.Menu "copy to clipboard" is disabled.
9
Part I: Interface
Manual version : 5.3.0
Password
Password3
Password button
The following interface is used to change the access level of the current user:
Enter password panel
To change your access level, enter directly the corresponding password and click on apply button.To close this panel and return to main controls, click on main controls button.
Remark: For touch screen users: when you click in control to be filled, the touchpad interfaceappears automatically.
Two levels are available for customers purposes:
LEVEL DEFAULT PASSWORD
user user
supervisor supervisor
To change default password please use the change password interface located in preferencespanel.
Parameters manager tolerances detection user Parameters manager analog interface supervisorParameters manager digital interface supervisor
Parameters manager measure supervisorParameters manager information supervisor
Lab configuration supervisor
11
Part I: Interface
Manual version : 5.3.0
Touchpad panel
Touchpad panel4
Touchpad interface
Touchpad interface appears when the user needs to enter text or numeric value by touching thecontrol.Restore button gives the capability to restore the source value.
Here below is presented the available configuration of touchpad:
Connexions manager interface gives the capability to add instruments in lines.
Connexions manager panel
Add connexion
Add connexion button
To add a new instrument to the current configuration, you first click on add button, a windowappears to configure the connexion.
13
Part I: Interface
Manual version : 5.3.0
Connexions manager
Connexions configuration panel
Configuration fields
Select instrument type: display all the CERSA instruments offer.Connexion prefix: Prefix used to display each measure and event names belonging to theconnexion.Color: instrument color to identify your product in the position target interface.Prod/Labs: select the connexion type. Lab connexion can't be inserted in production line andonly one connexion per line is allowed.
Labs connexion
Production connexion.
Line number: If CIM instance manage only one line, the default value is 1. If CIM manageseveral lines, the line number values must be different for each line. Please read lines managertopic for more information about line names.
Master instrument: Only one instrument in the line can have the master attribute. This attributeis used for display purposes only. For example: reset lines, spool time, spool length and spoolnumber measures are displayed by default only for master instrument. Rel. position: Is the distance in meters between instrument and zero reference for lengthcounting system.Connexion type: Physical type of connexion link. Validated only for RS232. If you use RS232connexion, Network address is set to 1.Comm. period: The communication period between CIM and instrument in seconds. CERSA-MCI recommends to set this period to 1 second to minimize the amount of recorded data andfree processor resources. Port number: CIM displays the list of all COM ports found by windows operating system.Baudrate: Baudrate configuration used by the instrument. By default set to 115200.Network address: Address of connexion in network. Network address must be <IPaddress>:<port number>.Search button: search in the network for compatible CIM connexions.
Search button.
This request can spent several minutes. The following interface appears:
By select and valid network location, the ip adress is displayed in network address field.
Please refer to the instrument manual for more details about the connexion type, baudrate andnetwork address settings.
Delete connexion
Delete connexion button
To delete connexion, select the corresponding line in the table and click on delete button.
Any change in the user configuration requires a reset in the line. The following message appearsto prevent the user that all the data will be lost:
Reset line message
Edit connexion
15
Part I: Interface
Manual version : 5.3.0
Connexions manager
Edit connexion button
To edit the connexion, select the corresponding line in the table and click on edit button.
Any change in the user configuration requires a reset in the line. The following message appearsto prevent the user that all the data will be lost:
Reset line message
Start/Stop
Start stop button
This function will starts or stops the communication between CIM and the instrument. In the sametime CIM opens or closes the COM port. This function is very useful if another application needsthe same COM port to configure instrument.
Save Preset
Save preset button
Save the display and parameters settings for connexions belonging to the line.
The following display settings are stored in the preset file:
Display zone: the zone where measures and events are displayed. Colors: colors used to display measures and events. Offset and amplitude: offset and amplitude values used to display measures in graphs.Position: position of measures and events in tables and graphs.
The following parameters manager settings are stored in the preset file:
This function load preset in the first empty line.
The following interface give to the user the capability to choose the parameters to be imported.Display setting are always imported.
See Parameters manager for complementary information.
17
Part I: Interface
Manual version : 5.3.0
Line manager - Laboratory
Line manager - Laboratory6
Lines manager panel for the Lab.
This interface configure global line parameters for lines in laboratory configuration.
Database Status : Indicate if the database is reachable.
database is reachable
database is not reachable. If database is not reachable, verify the path or the network to continue to access the database.
Line number: the line number is the line identifier, a software internal identifier.Line name: use this field to enter the names of your lines. For example if you have 3 lines: LabMachine 1, Lab Machine 2 and Lab Machine 3 on the same CIM software. Filtering group: Define how many groups are requested by the interface. The results are sortedfrom oldest to newest. The default integer value is 20. Filtering Records: Define how many records are requested by the interface for specific group.The results are sorted from oldest to newest. The default integer value is 20.Database path: The path to the lab database. This file must be create by the "LabConfiguration" interface (Lab configuration), the database is a sqlite specific database and musthave the dblab extension. Record Nb. : The total number of record in database.
When the number of records in the database reaches the limit of 150 000, no record orgroup can be added. To continue with database, you must use the archive function.
This button allows to change the database for the specified line. It opens a window toselect a new database file.
This button allows to archive current database, and start with a new empty file. You cankeep group definition and database configuration.
Archive a database :
When you want archive the database, a window appears to specify the archive file. A warningwindow is shown. Then, this window appears :
This button allows to specify the path for the archive file.
File name: the name of archive file. By default, the archive name is the database of Labs withthe date and time.
Keep group information: If it's selected, all existing groups are kept into the database. Otherwise a new name for the lab database is necessary. The group is removed but the supervisorconfiguration is kept.
Important: ln case of other CIMLab in other PC uses the same database, you must modifythe configuration respectively.
New file name: New name for the lab database (Available only in case of "Keep group
19
Part I: Interface
Manual version : 5.3.0
Line manager - Laboratory
information" is unselected )
Valid the archive of the database, empty the current database.
This table displays the status for each connexion belonging to the line. The first column display connexions names linking the instrument name and serial number. The second column display short name for the instrument error codes. Refer to the instrumentmanuals for more information about error codes.The third column displays icon which represents the status of the connexion.
Connexion status icons
The status of connexion is defined by the following list:
Connexion run icon: The connexion is running without problem.
Connexion break icon: The main communication is not enabled for this connexion.
Warning icon: The instrument sends an error code. Error codes include wrong position and temperaturealarms.
Connexion reconfiguration icon: CIM reconfigures several parameters in connexion.
Connexion clear events icon: CIM clears events in instruments.
Connexion reset line icon: Connexion has been reset in order to reset line.
21
Part I: Interface
Manual version : 5.3.0
Main interface Lab
Connexion disconnected icon: Connexion is disconnected.
Connexion start stop error icon: Problem to start or stop COM port.
Connexion process icon: The connexion processes parameters.
Connexion comm error icon: Communication error.
Connexion compreg error icon: This error appears when the user changes parameter and the requestedvalue is not the same as the value stored by the instrument.
This status represents the connection and accessibility of the file database (dblab file type)configured in the line manager. ( Lines manager )
Status Ok : the database can be reach to save measure
Status Nok : the database can't be reach. Problem to access the file, verify the path of database.
Com printer Status
this status indicate if COM printer is defined and opened. See the preference panel to configureLabel printer ( Label printer )
Status Ok : the COM port is defined and opened, you can print a label after each sample acquisition oron a selected sample acquisition.
Status Nok : the COM port is not defined or not opened.
23
Part I: Interface
Manual version : 5.3.0
Main interface Lab
Measures and events7.3
M easures table
This table shows in real time all the measures and related events of the instruments belonging tothe line. When out of tolerance is detected in measure an event is reported under the measure's name ofthis table.
o Out of high tolerance icon.
o Out of low tolerance icon.
o Warning high tolerance icon.
o Warning low tolerance icon.
The display refresh time of this table is about one second. The name of each measure can be setin measures manager and it is prefixed by connexion prefix defined in connexions manager.
At the bottom of the main screen, the control panel button display multiple functions specifics foreach zone.
Control panel button
25
Part I: Interface
Manual version : 5.3.0
Main interface Lab
Group management7.5A group is a set of similar sample acquisitions.
In this example, we defined two groups, one for all the acquisitions of cuper wires, and one for allthe acquisitions of steel wires.To differentiate two groups, we can add a freefield to enter the type of wires, steel or cuper in thisexample .
Group Tab
The group Tab contains two principal zones :
- In the left side a table that shows the groups available's in the database (see Group table ).- In the right side a few buttons ( see Group actions ) and filter controls (see Filter group ).
When you configure the first laboratory connexion, a default database is created. This database isin "Easy" mode.This mode is a simple samples acquisition.Any configuration is needed to perform sampleacquisition and save in database.
The group is created automatically with the current accessory configuration and the current unit.The group, according to the instrument configuration, open automatically the group and you areready to perform sample acquisition.Only one group per configuration (Unit/Accessory) is allowed.
Expert mode7.5.2
To benefit of the "Expert mode" features, you must change the database configuration. This change allows you to create many groups, create freefields, or use user login.
When database is in this mode, it is impossible to return in easy mode.
What is freefield ?7.5.3
For the laboratory configuration we use the term of "Freefield" to define a sample or group featurecreated by the user.
In CIMlab all the data are stored in SQLite database. CERSA preset the database with statisticsfields, instrument parameters and others fields like, date, time and user.To add specific parameters, we add the "freefield" field.
Each freefield add by the user appears like an additional column for sample or group record.
27
Part I: Interface
Manual version : 5.3.0
Main interface Lab
Group table7.5.4
Number of acquisitions in group
Button to inform if the group is opened or closed
Name of the user that have create the group if user login is activated
Freefields values defined when group has been created
The grey line indicate the selected group
Measures unit when group has been created
Detail of Group table
the group is open
(Foot pedal) or (WSR) group is close. The icons allow you to know the group'stype (Foot pedal or WSR group).You can not mix the measure's type.
You can choose which groups will be displayed in the table filter by the following criteria.
Date filtering : Request groups between start and stop date.Filtering Group : Request the n latest groups created in the database. In the example, we wantonly the 20 last group in database.User list : Request groups created for an specific user. No user is the group defined whensupervisor configure "No login" on group.
Apply the filter, the table is erased, the request is sent to the database and the result isdisplayed into table.
Group actions7.5.6
This button open a group. This button is active only if a line of table is selected.
This button close a group. This button is active only if a group is open.
29
Part I: Interface
Manual version : 5.3.0
Main interface Lab
this symbol indicate the opened group in table
This button allows to create and configure a new group, only in database expert mode. ifyou are in easy mode, a message is shown to inform you that you must change to the expertmode.( See Lab configuration for more details )
When database is full, no group can be added or opened. A window is shown to inform the user. Ifthe database is almost full, a message informs the user.You must use the archive function to avoid the message after each opened group.To consult a full database, please use the load file function in main control panel. See Loaddocumentation.
Create new group
if group freefields are defined, when you want create a new group this windows appears :
Name column : The name of the field defined by the Supervisor. See the Lab configuration forcomplementary information.Necessary column : this column inform the user if the field must be filled or not.
Not necessary : It is not necessary to fill the field by the user. It's just complementaryinformation.
Necessary : This field must be fill by the user. If no information is enter, the user receive awarning popup like this :
Value column : the user inform the value of the freefield into this column with a double click onthe field, or uses arrow to choose the right value in the list.
Login for new group
Login panel
The user list has been defined by the supervisor in the database configuration.
Open group
Open a selected group.
When we open a group, a filter window is displayed to filter the acquisitions already present indatabase for this group.
31
Part I: Interface
Manual version : 5.3.0
Main interface Lab
Date criteria
Button to apply the filter User criteria
Last n record criteria
Choose the filter to apply
Record’s number in database
Acquisitions Filter
You can adjust the parameters to display only some specific acquisitions.
Date filtering : Request records between start date and stop date.Filtering Records : Request the last n records stored in the database for current group. In theexample, we want only the 20 last sample's acquisition in database.User list : Request records created by an specific user in the current group. "No user" is whensupervisor configure "No login" on acquisitions.
Apply the filter, the request is sent to the database and the result is displayed into table.
Statistics tab The informations of the open group.
Lab main
The Lab window contains 3 zones :
- Acquisition points : Show each point of the acquisition (degree/value for WSR, or number/valuefor Footpedal)- Acquisition graph : the graphical representation of a wire sample acquisition.- Statistics tab : the different way of the representation of statistics have been shown in the 3 tabs.The first represents the evolution of each acquisition as a line with statistics value, the secondrepresent each statistics, under graphics representation, and the third represent the statistics overthe set of acquisition's statistics present in Stats Tab.
General information of the opened group are shown in the lateral panel.
When database is full, no record can be added. A window is shown to inform the user. If thedatabase is almost full, a message informs the user after each ten wire sample acquisition.
33
Part I: Interface
Manual version : 5.3.0
Main interface Lab
Points acquisition7.6.1
The measure table contains each value of the measure.
M easure's points with error (WSR samples)
In the case of some points are in error state, the error appears in table with the error number.To know the description of the errors, please refers to the instrument documentation.
A contextual menu appears on a right click button of the mouse.
Contextual menu in table (FP samples)
In this table, you can copy selected cells or the entire table to clipboard. This can help you to treat the measure data in other software, like Microsoft Excel.
Measure representation, with error (red line), and valid point (blue line)
Scales configuration
Description of graphical zone
This zone represent the measure evolution versus angular position for WSR or versus the numberof points for foot pedal in graphical mode.The error points have been shown as a red points and line, the valid points in blue.
This button allows to modify graph scales.
Automatic / manual mode
Quit the window
Values of scale
35
Part I: Interface
Manual version : 5.3.0
Main interface Lab
The check box can specify if the X or Y scales are automatic or manual. In manual mode, youmust specify a valid values, otherwise graph can be display out of the graph window. If all of the scales are in automatic mode, the text on the right of the button shows "Autoscale" (
).If one of the scales are in manual mode, the text on the right of the button shows "Manual scale" (
).
Note : If two lines or more are selected, no graph appears.
Statistics tab7.6.3
Statistics graph
Statistics of statistics table Statistics table
Statistics zone
There are 3 tabs to display acquisitions's results.
- Stats tab : In this tab are displayed the statistics for each acquisitions.- Graph tab : this display is graphical representation of the statistics table. Evolution of statisticfor each sample.- Stats/Stats : This tab display the statistics over the acquisition's statistics present in tab"Stats".
Statistics table
Acquisition selected Button to delete selected acquisitions
When users performs an acquisition with a lab instrument, a line in the table is added and the lastacquisition is selected.When we select an acquisition in table, the graph and the table of acquisition's points is refreshed.You can reload all the measures.
To remove measures, you must select one or more line by maintain pressed the keyboard's key
and click on line.
Then, click on the button .
The measures are removed from the table and the database.
To print a label, first select a line in table, and then click on to print Label.Note : you must configure the COM port for the label printer in preference panel ( see Preferencespart )If automatic print is activated, after each sample's acquisition, a label is printed.
In the table, there is some information predefined or defined by the user.
Predefined fields :- User : is the name of the operator who do the wire sample acquisition if database is configured torequest login. If no user is requested, this field is empty.- Date / Time : The date and time of the acquisition.
Statistics fields :- Nb. : is the numbers of point of the acquisition.- Average : Average of the acquisition.- Std dev. : Standard deviation of the acquisition.- Min : the diameter minimum of the acquisition.- Max : the diameter maximum of the acquisition.- Roundness (WSR)/Deviation(Footpedal) %: roundness or deviation of the acquisition.- Ovality(WSR)/Deviation(Footpedal) µm : deviation of the acquisition.- Error : the pourcent of the acquisition's error.
sample freefields :The sample freefields are present after statistic fields if user has been defined in the database.To define freefields, please see Lab configuration documentation.
37
Part I: Interface
Manual version : 5.3.0
Main interface Lab
Graphical stats
Graphical zone Number of acquisition in statistics table
Statistics to display
Button to manage the scales
Two vertical axes for statistics values
graphical view of statistics
In Graph, are displayed the evolution of statistics values. The X axis represents the number ofacquisitions in statistics table.In this graph, you have two vertical axes that can represent different statistics in different scales.
In the graph, the point is represented by a cross plot for the left axis ( ) and an empty
square for the right axis ( ).The color of each statistic can be choose by the user in lab configuration ( Lab configuration ).
This button allows to access at the scales parameters window.
Values of scale
Quit the window
Automatic / manual mode
If all of the scales are in automatic mode, the text on the right of the button displays "Autoscale"
( ).
If one of the scales is in manual mode, the text on the right of the button displays "Manual scale"
The table represents the statistics over the statistics acquisitions present in tab Stats.
Min of the statistics Minimum of the averages
Minimum of the minima
Statistics table
Statistics of statistics table
This value is the minimum of the minima
This value is the minimum of the averages
Average of the maxima
The column represents the statistics calculation on the statistics :
Nb. : this column represents the number of measures taken for the statistics.Min : this column represents the minimum of the statistics.Max : this column represents the maximum of the statistics.Average : this column represents the average of the statistics.Std. dev. : this column represents the standard deviation of the statistics.
39
Part I: Interface
Manual version : 5.3.0
Main interface Lab
Add measure7.6.4
After an acquisition, the points table and the graph of the acquisition are displayed, then, ifsample's freefields are defined, a window is shown before to complete the acquisition by theoperator
Freefields name Inform if necessary
Values to complete.
Name of the user logged.
Valid or cancel the acquisition
Necessary : This configuration impose the user to complete the field.
If user login is activated, this window is displayed before to accessed the sample freefield window.
Login window for the data
This window must be completed before validate the data.
41
Part I: Interface
Manual version : 5.3.0
Main interface Lab
Measures manager7.7
M easures manager zone
This interface gives the possibility to transmit (RS232 communication), display and configuremeasures and events from the instruments belonging to the line. All available measures for eachinstrument are displayed in "select transmitted measures" table.
The following icons define the status of the measure:
The selected measure or event is always transmitted. User cannot delete or add from currentconfiguration.
Any change in the user configuration requires a reset in the line. The following message appearsto prevent the user that all the data will be lost:
Reset line message
Settings tab7.7.1
Settings tab
When the user selects a transmitted measure, this interface displays its settings and gives thepossibility to change the current configuration. When a non transmitted measure is selected thisinterface is dimmed.
43
Part I: Interface
Manual version : 5.3.0
Main interface Lab
The following settings are displayed:
Default name
Is the default CERSA name followed by the serial number of the instrument. This default namecannot be duplicated and is located at the top left of the settings tab interface.
General settings
Name: This control displays and gives the possibility to change the user measure name. Thisname will be used in all the software interface.Color: This control displays and gives the possibility to change the user measure color. Thiscolor will be used in all the software interface.Display: This control displays or hides the measure (and measure event if exist) in measuresgraphs, event graphs and measures tables.
Not displayed / displayed icons
Measures graph settings
Amplitude: Defines the default amplitude.Offset: Defines the default offset. The default configuration can be restored from graph settingswindow. Production display: This control displays or hides the measure in production graphs.Custom display: This control displays or hides the measure in custom graphs.Left and Right: These controls change the position in the measures axis table.
Left & Right icon
Events settings
Production display: This control displays or hides the event in production graphs.Custom display: This control displays or hides the event in custom graphs.Up and Down: These controls change the position in the events graph.
Up & Down icon
Measures table settings
Lite display: This control displays or hides the measure in lite table.Full display: This control displays or hides the measure in full table.Custom display: This control displays or hides the measure in custom interface.Up and Down: These controls change the position in the measures table.
Scope manager7.8Scope manager zone gives the capability to make the acquisition of CERSA instruments internalsignals and displaying it in scope interface. User can add several scopes interfaces in order tomake correlations between signals.
To add scope interface push add button in control panel. Then the following interface is displayed:
Scope interface
Each scope interface can display several synchronous signals in different channels and/or indifferent graphs.
Scope cursors are available and help the user to manage the displaying. Full screen mode can beactivated or deactivated by right click in desired graph.
When the scope manager zone is displayed the control panel shows the following functions
Scope manager control panel
Add scope7.8.1
Scope add button
This button adds scope interface in scope manager zone. The new scope is positioned just afterthe last added scope.
47
Part I: Interface
Manual version : 5.3.0
Main interface Lab
Select signal7.8.2
Select signal menu
This ring control shows the available signals for instruments belonging the line. The list here belowshows several examples:
CCD diffractionReal time diameter interferometryReal time tensionSpinning evolutionVibration FFT
For more details about configuration of signals please refer to instrument manuals.
Signal tab7.8.3
Signal tab
In this tab are displayed result controls (blue color) and parameters controls (green color) toconfigure signals correlated with scopes. Parameter controls can be adjusted only when scopeacquisition is stopped otherwise controls are dimmed.
In this tab user can select the signal processing to apply over the signal.
FFT signal processing
Signal is displayed in blue color and the FFT signal process is displayed in red color.
Scope "FFT diameter airline" example with FFT signal processing
Statistics
The average, standard deviation, minimum and maximum values are computed over the signal. When this signal processing is selected the values associated with the cursor are not displayed.You need to select none to display cursor values.
49
Part I: Interface
Manual version : 5.3.0
Main interface Lab
Scope statistics process
Scale tab7.8.5
Scale tab
This tab allows the user to change the scale mode of X and Y axis.
Scale mode axis
Three scales modes are available for each axis:
Default: the instrument chooses the scale to display.
Automatic: CIM seeks minimal and maximal values and displays the signal regarding thesevalues.Manual: user can change manually the minimal and maximal values for each axis.
Display tab7.8.6
Display tab
In this tab the user can manage channels and cursors related to the scope.
Channels and cursors
The number of channels and cursors are defined by the instrument.
Two display modes are available:
Default: The instrument chooses the channels, cursors and colors for displaying. Manual: The user can choose the channels, cursors and colors for displaying.
The cross cursor legend displays the X and Y position of the cursor related to the graph scale.This cursor also gives the value of the nearest point related to the selected channel.
51
Part I: Interface
Manual version : 5.3.0
Main interface Lab
Delete scope7.8.7
Delete scope button
This button delete scope interface.
Refresh time7.8.8
Refresh time numeric control
This parameter defines the acquisition and display period expressed in seconds. Therecommended value for this parameter is one second. Smaller values can be applied to thisparameter but this action will use more resources.
Start stop scope7.8.9
Start stop button
This button starts and stops acquisition of signals from the instrument. To configure the scope youfirst have to stop the acquisition.
When you quit the scope manager zone, the acquisition of all scopes are automatically stopped.The acquisition will be restarted when you come back to the scope manager zone.
Save scopes7.8.10
Scope save scopes button
By pushing this button, the user will be able to store in one single file all scope interfacesdisplayed in scope manager zone. The following interface will appear to locate and name the file.
The extension of this kind of file is ".cimscp". The recorded file can be open with load functionlocated in main control panel.
Save sequences7.8.11
Scope save sequence button
With this function you will be able to save sequence of displayed signals during a time period inone single file. You must enter the number of seconds that you want to record in the followinginterface.
Save sequence panel
Then the recording will run automatically. The following interface will appear at the end of record tolocate and name the file.
53
Part I: Interface
Manual version : 5.3.0
Main interface Lab
Save file panel
CERSA can request you to send several signals in one single file to have a good statistic view ofyour process. This kind of tool is necessary in order to help you for advanced settings and improveyour measurement.
The extension of this kind of file is ".cimscp". The recorded file can be open with load functionlocated in main control panel.
This interface allows user to configure tolerances and detection parameters of instruments. Eachmeasure or detection feature displays their tolerances in individual subregion tab. When the measurement value is outside the range, defined by the tolerances, the instrumentgenerates an event. These events are displayed in events graph.
The following configurations can generate events:
Measure > Nominal tolerance + Warning high tolerance EVENT WARNING HIGH
The following parameters configure the analog outputs of the instrument.
Test DAC: allows the user to make several tests over the analog outputs to verify a normalbehavior of the instrument.Configuration: defines electrical type configuration of analog output. Please contact CERSA-MCI for more details about this parameter.Measure: defines the forwarded measure in analog output.Zero point: when the measured value reaches the zero point value, the correspondinganalogical output is set to 0V. The unit of the zero point is the same as the correspondingmeasure.Scale: is the number of volts per measure unit. For example for position in millimeters 2 [V/mm]: if the measure varies of 1mm the value of analog output varies of 2 Volt.Regulation: if this option is activated, then the zero point value is automatically forced to thenominal tolerance value of the corresponding measure. Otherwise the zero point can have anyvalue.Average time: is the average time used to compute the analog output signal.
57
Part I: Interface
Manual version : 5.3.0
Parameters manager
Digital interface8.3
Digital interface tab
This tab contains two subregions in order to configure the digital interface of the instruments.
Test digital outputs
Allows the user to make several tests over the digital inputs and outputs to verify a normalbehavior of the instrument.
Digital input/outputs
This subregion allows user to configure input/outputs signals. The following configurations aregenerally used to give or receive a reference, event, alarm or status:
UNAVAILABLE (not exist in the current instrument)INPUTOUTPUTINPUT OUTPUTREFERENCE
Length counting
Pulse number: the number of pulses for one meter length.Measure: in case of the real speed and the measured speed are not perfectly correlated, youcan adjust this factor.
Please refer to the instrument manual for more details about configuration of digital input/outputs.
When a group is open, "Trigger mode" can't be modify by the Supervisor. To change equipment on LDS instrument ( WSR -> FootPedal ), you must close the group.
The control Trigger mode becomes active and can be switch on the different values.
59
Part I: Interface
Manual version : 5.3.0
Parameters manager
Measure8.4
M easures tab
This interface displays all parameters relative to the measure of the instrument. Each measuredisplays its parameters in individual subregion tab.
Please refer to the instrument manual for more details about specific instrument measureparameters.
In this tab are displayed all informations relative to the general instrument configuration: Internalsoftware versions, hardware versions and safe internal information. These informations can berequested by CERSA-MCI for assistance.
61
Part I: Interface
Manual version : 5.3.0
Parameters manager
Eeprom8.6
In this tab you can make load default action in order to restore factory data settings for relatedinstrument.
In this interface are displayed parameters related with scopes interfaces.
63
Part I: Interface
Manual version : 5.3.0
Lab configuration
Lab configuration9
Lab configuration button
All the database configuration of your lab is available in this interface.
When lab connexion is created, a default database is attached to your line. The default databaseis created in "Easy" mode. By clicking on "Lab configuration" button, a popup appears to answer if you want to open the firstlab line directly (Yes) or start the Lab configuration without database opened (No).
The interface of the database configuration for the lab :
Open a database. A file select window is open to choose your file.
Create a new database.
After clicking on this button "Create a new database", a windows is opened to choose path andfilename of the database :
Valid the creation of the database
Cancel the creation of the database
65
Part I: Interface
Manual version : 5.3.0
Lab configuration
Configure a database9.2This chapter explains the different terms used to configure a database.
Tabs description :
In the lab configuration, three tabs are present to configure the database.
Group configuration Sample field configuration
Configuration of the operators
Easy mode9.2.1
By default, if you create a database, the easy mode is active.
This mode is an automatic group creation, an automatic open for your instrument/CIM softwareconfiguration.In this mode you can not create manually new group, and only one group per configuration isallowed.
Expert mode9.2.2
If you change the database to expert mode, a warning message is shown.
If you accept, the database will pass in expert mode, the button is dimmed and you can not returnin easy mode for the current database.
in expert mode, you can use all of CIM laboratory's features.
See Group management and create new group for more informations.
this window has 2 parts :The description and the configuration of group freefieldThe list of the values of the group's freefield if it is defined as a list.
67
Part I: Interface
Manual version : 5.3.0
Lab configuration
Name of field that appears when we create groups
Field must be completed
Field in list
Disable and hide the field when we create groups
Disable and hide the field list when we create group
Name of the list element
Necessary : This configuration forces the user to complete the field when it creates a group.
Freefield in list : This configuration chooses if the group field is an edit box or a list valueswhen user creates group. If the button is checked, a table appears on the right part and allows toadd and edit the list of fields.
Sleep : This button allows to hide a field previously defined. Field cannot be erased when theyare already used. If this button is checked, this field is not shown in the "Create group" windows.
Add a field in table.
Remove a field in table. If the database has been previously defined, this button is hidden.This button is shown only when a new database is created.
See Lab measure and Add measure for more informations.
this window has 3 parts :The description and the configuration of data freefield.The list of the values of the data's freefield if it defined as a list.The list of the instrument statistics that it changes with the list box of instrument's type.
69
Part I: Interface
Manual version : 5.3.0
Lab configuration
Data freefield configuration9.4.1
Name of the list element Field in list
Disable and hide the field when we acquire samples.
Field must be completed by user
Disable and hide the element list when we acquire sample.
Name of field that appears when we acquire samples.
Necessary : This configuration force the user to complete the field when it makes a sample'sacquisition.
Freefield in list : This configuration chooses if the data field is an edit box or a value list whenuser makes a sample's acquisition. If the button is checked, a table appears on the right part andallows to add and edit the element list .
Sleep : This button allows to hide a field previously defined . If this button is checked, this fieldis not shown in the "Sample acquisition" windows.
Add a field in table.
Remove a field in table. If the database has been previously defined, this button is hidden.This button is shown only when a new database is created.
Sleep : This button allows to hide a user previously defined. If this button is checked, this useris not displayed in the "user list" in login window.
When a user is selected, by clicking on the check box "Show password", the password is shown.When the user select an another user, the password is displayed with stars.When supervisor creates a new user, and a new password, user can visualize the password typedby clicking on the check box.
User must login on group creation or after each sample's acquisition.
No login needed
Add a user in table.
Remove a user in table. If the database has been previously defined, this button ishidden. This button is shown only when a new database is created.
73
Part I: Interface
Manual version : 5.3.0
Load
Load10
Load file button
This function loads files that were created in production or in scopes. The following extensions arerecognized by the software:
.cimprd Created in production interface using save selection function. Or created automatically when cim data file record option is active in linemanager.
.cimscp Created using scope manager interface with save scopes or savesequence functions
.cimzip This file represents compressed data for production or scopes. Usepreferences interface to enable or disable this function.
.dblab This file represents the SQLite database of a lab line. It contains data and"wire" sample acquisitions, group of acquisition and cersa data.
Several files can be opened at the same time and the production runs simultaneously. Here belowsome examples of opened files.
In this scope file the next signal, previous signal and go to signal buttons are available to navigatein recorded signals. See save scopes and save sequence buttons for more details about savefunctions.
Previous and Next signal button
Go to signal control
75
Part I: Interface
Manual version : 5.3.0
Load
Lab files10.2
Database opened with load function
The groups created in database are displayed. The interface is the same as the "Main interface",only the button "New group" is not present in the viewer lab interface.
Please refers to the Main lab interface for more information :
Preferences interface contains options related to the software.
Change password: See change password topic for more details.File compression: This option will compress CIM files automatically when the user make saveselection, save scopes, save sequence or in automatic cim data file record. Compressed fileshave .cimzip extension.Reconfiguration: When this option is active CIM will configure automatically productionparameters (as tolerances, analog outputs and digital inputs - outputs for example) when newconnexion was detected.Enable notification popup: When this option is active CIM will display notification managerwindow until the user valid all non acknowledged messages.Label printer : This button show a window to configure the Label Printer for the laboratory part.Please refer to Label printer topic for more details about how to configure printer part.Languages: This button show a window to choose the software language. The modification isapplied after restart the software.Unit display: This button show a window to configure the units in CIM software. Themodification is applied after restart the software. Please refer to Unit display topic for moreinformation.Report configuration : display interface to configure the reports. Please refer to Reportconfiguration topic for more information.Autosave : Enable automatic save of current production file when failure.Cim Id: Unique identifier for CIM instance in your factory. This parameter needs to be configuredin case of external database architecture. Please refer to line manager topic for more detailsabout line production configuration.Timeout ack.: Timeout used in each communication between CIM and the instrument in orderto start the exchange. The recommended value is 1 [second].
77
Part I: Interface
Manual version : 5.3.0
Preferences
Change password11.1
Change password panel
This interface allows you to change password for customer levels. To make this please follow thisprocedure:
Select the level to change.Enter the new password.Confirm the new password.Apply changes.
To modify supervisor and user password you need to know supervisor password in order to displaypreferences and change password interfaces.
Configure the computer COM port that communicate with the LP ( Zebra or Sato label printer).Select if the label must be printed automatically after each sample's acquisition .Send label template to the printer.
Close the LP windows and return to the preferences windows.
general configuration11.2.1
Computer COM port configuration
This window configure the computer COM port to communicate with the Label printer. By default, the label printer works with a 38400 baud's speed.
To open the COM port, select the COM port in list and click on the button .
The computer COM port is opened and list is dimmed
79
Part I: Interface
Manual version : 5.3.0
Preferences
To close COM port, click on the button.
The computer COM port is closed.
Lab configuration11.2.2
Lab configuration
This window allows to print label after each sample's acquisition.
This window allows to configure your LP with a template.To use it connect the label printer to the computer COM port. ( see Label printer generalconfiguration for more information ).
On the left part of this window you have filters to choose which labels are displayed on "labelselection" control.
o Label unit : Filter on metric or imperial units.
o Label CIMLAB filter : filter the CIMlab labels. You must select the label with this filter if you
want to print from CIM software.o Label Instrument filter : filter the Foot Pedal (FP) or Wire Sample Rotation (WSR). You
must select the label with this filter if you want to print directly from instrument (for example,LP connected on LDS).
On the right part you see a label preview.
Click on this button to send template to the LP and print a label for test.
This button is used for LP maintenance, with specific files sent by CERSA.
81
Part I: Interface
Manual version : 5.3.0
Preferences
Unit display11.3
Configure the unit display in CIM software.
Global unit : Set the unit for all measures in CIM software.
o Metric unit ( Internationnal System unit ).
o Imperial unit ( English unit )
Length/Speed unit : you can dissociate the length or speed unit.
o Metric unit ( Internationnal System unit ).
o Imperial unit ( English unit )
After changes CIM software must be restarted to apply the change.
Toolbox interfaces are individual CIM modules that allow the user to perform different actions.When the user click on this button the toolbox panel shows the following toolboxes:
Export to CSV.
83
Part I: Interface
Manual version : 5.3.0
About
About13
About CIM button
Click on this button to display company information, software version and help contents.
By click in display manual button the following window will appears:
Display manuals button
Select manual window
To open manual in html format select item and make double left click or push in validate button.