Top Banner
Hello Rf, goodbye Ra ?! Prof. K. Smet Celebrating the 20 th anniversary of the Light&Lighting laboratory Ghent, September 12, 2017 CIE CRI:
23

CIE CRI: Hello Rf, goodbye Rauuid:e604… · colour differences in U*V*W* IMPORTANT impact of colour space on fidelity scores: Drop is for the largest part a result of the update

Oct 24, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
  • Hello Rf, goodbye Ra ?!

    Prof. K. Smet

    Celebrating the 20th anniversary

    of the

    Light&Lighting laboratory

    Ghent, September 12, 2017

    CIE CRI:

  • Colour Perception

    2

  • Colour Perception

    3

    Inform about

    object

    identity and state

  • Colour Perception

    4

  • Colour

    rendition

  • Colour

    rendition

  • ?

    How do we measure color rendition?

  • A light source can induce different types of

    color distortions

    Reference

    color

    Hue shift

    a’Saturating

    shift

    Desaturating

    shift

    b’

    ∆𝑬 = ∆𝑳 𝟐 + ∆𝑯 𝟐 + ∆𝒔 𝟐

    ±∆𝑯

    +∆𝒔

    −∆𝒔

  • 𝑹𝒂 = 𝟏𝟎𝟎 − 𝟒. 𝟔 ∗ ∆𝑬𝟏−𝟖

    Test lamp

    same CCT reference illuminant

    Planckian

    CCT < 5000 K

    Daylight

    CCT ≥ 5000 K

    ∆𝑬𝟏−𝟖 (U*V*W*)

    Color rendering (fidelity), CIE Ra

    Ra(CIE13.3 1995)

    13

    4

    2

    Color rendering: “Effect of an illuminant on the color appearance of

    objects by conscious or subconscious comparison with their color

    appearance under a reference illuminant”

  • 𝑹𝒂 = 𝟏𝟎𝟎 − 𝟒. 𝟔 ∗ ∆𝑬𝟏−𝟖

    same CCT reference illuminant

    CIE Ra >> IES Rf >> CIE Rf

    Planckian

    CCT < 5000 K

    Daylight

    CCT ≥ 5000 K

    ∆𝑬𝟏−𝟖 (U*V*W*)

    1

    2

    3

    4

    ∆𝑬𝟏−𝟗𝟗 (CAM02-UCS)

    𝑹𝒂 = 𝟏𝟎 ∗ 𝒍𝒐𝒈(𝒆𝒙𝒑((𝟏𝟎𝟎 − 𝒄 ∗ ∆𝑬𝟏−𝟗𝟗)/10) +1)

    Planckian locus

    Daylight locus

    4000K

    4500K5000K

    5000K

    5500K

    4500K

    same CCT reference illuminant

    8 spectrally non-uniform Munsell samples

    99 spectrally uniform samples

    cIES = 7.54 cCIE = 6.73

    * Some CIE spectral are slightly

    different from IES samples due

    to extrapolation differences

    beyond 400 nm and 700 nm

    *Important updates: sample set & color space

  • Color rendering (fidelity)

    What CRI does NOT convey:

    • Direction/type of color shifts

    • Difference in color for any

    specific object

    • How one source will make things

    look compared to another

    • Information on color

    discrimination, preference,

    naturalness, …

    What CRI conveys:

    • (average) magnitude of

    color fidelity / color shift

    a’

    b’

  • Color space improvement

    a’ b’

    J’

    good (better) chromatic

    adaptation formula (CAT02)

    good (better) colour

    difference formula

    good perceptual uniformity

    no CCT dependence

    Replacement of outdated U*V*W* with state-of-the-art CAM02-UCS:

  • Rf with U*V*W*

    410 nm Underestimation of Yellow-Blue

    colour differences

    in U*V*W*

    IMPORTANT impact of colour space on fidelity scores:

    Drop is for the largest part a result of the update to the

    perceptually uniform CAM02-UCS space

    Short wavelength sensitivity simulations: Warm-white phosphor LED (3000 K)

    Blue pump LED shifted from 410 nm to 480 nm

    CIE Ra

    Rf with CAM02-UCS

    Color space improvement

    a’ b’

    J’

  • Replacement of the CIE CRI Munsell test color

    samples (TCS) with special Color Evaluation Samples (CES):

    Larger sample size (8 99)

    More information

    Better statistical accuracy

    Uniformly distributed (3D) in color space

    Spectral or wavelength uniformity

    No wavelength bias

    No selective spectral optimization

    a’ b’

    J’

    50

    55

    60

    65

    70

    75

    80

    85

    90

    95

    100

    Rf b

    y hue

    Sample set improvement

  • Wavelength uniformity We need to make sure that the sample set treats all wavelengths equally.

    Why? It is possible to generate many colors with only 3 “pigments”!

    l (nm)400 500 600 700

    Pig

    me

    nt

    refl

    ec

    tan

    ce

    Re

    fle

    cta

    nc

    e

    0%

    100%

    l (nm)400 500 600 700

    But the corresponding samples are mostly sensitive to a few wavelengths

    Sample set improvement

  • Wavelength uniformity We can compute the “wavelength sensitivity” for a sample set (r’2, r”2…)

    400 450 500 550 600 650 7000

    0.5

    1

    1.5

    2

    2.5

    3

    3.5

    4

    4.5

    5x 10

    -4

    l (nm)

    Sen

    siti

    vit

    y t

    o S

    PD

    var

    iati

    ons

    Black = 3-pigment set

    Blue= CIE TCS 1-8

    Red = IES 99 CES

    l (nm)400 500 600 700

    Ref

    lect

    ance

    0%

    100%

    Sample set improvement

  • Wavelength uniformity Example of selective spectral optimization of light source SPDs:

    RGBA laser line source (3000 K)

    Red peak wavelength shifts from 590 nm to 670 nm

    Colour fidelity score can

    anomalously exceed the

    values at nearby wavelengths

    by 5 units or more.

    Sample set improvement

  • light source 1 light source 2

    Ra = 81, Rf = 80 Ra = 80, Rf = 49

    Comparison between an existing LED source and a possible

    narrowband source, having the same Ra but different Rf

    Color rendering example

  • Hyperspectral images rendered with IES 4900 Refset under 3000 K

    Ra = 100, Rf = 100 Ra = 100, Rf = 100

  • Hyperspectral images rendered with IES 4900 Refset under 3000 K

    Ra = 81, Rf = 80 Ra = 80, Rf = 49

  • CIE Rf calculators

    (Unofficial) Matlab and Excel

    calculators can be

    downloaded from:

    www.github.com/ksmet1977/

    CRI_CIE_Rf_2017/

    A calculator for Python is

    also part of the luxpy

    package (install using pip:

    “pip install luxpy”)

    The official Excel calculators

    for 5nm and 1nm spectral

    data can be downloaded from

    CIE upon purchase of the

    CIE224:2017 technical report

    (http://www.cie.co.at/index.ph

    p?i_ca_id=1027)

    http://www.github.com/ksmet1977/CRI_CIE_Rf_2017/http://www.cie.co.at/index.php?i_ca_id=1027

  • • The CIE Ra has imperfect samples andoutdated color science leading to

    inaccurate assessment of color fidelity.

    • The new CIE Rf fixes this by:

    o Improving the color space to the

    uniform and CCT independent

    CAM02-UCS

    o Improving the color samples:

    Spectral uniformity eliminates

    wavelength bias ensuring selective

    spectral optimization becomes much

    harder.

    Larger, more varied sample set

    provides more info and better

    statistical accuracy

    400 450 500 550 600 650 70000.51

    1.52

    2.53

    3.54

    4.55x 10

    -4

    l (nm)

    Sen

    siti

    vit

    y t

    o S

    PD

    var

    iati

    ons

    Summary

  • [email protected]

    More info: • CIE. (2017). CIE224:2017, CIE 2017 Colour Fidelity Index for

    accurate scientific use. CIE, Vienna, Austria. ISBN 978-3-

    902842-61-9. (http://www.cie.co.at/index.php?i_ca_id=1027)

    • Smet, Kevin A.G., David, Aurelien, & Whitehead, Lorne.

    (2016). On the importance of color space uniformity and

    sample set spectral uniformity for color fidelity measures,

    CIE2016 Proceedings, Melbourne, March, 3-5, 2016, OP22.

    • Smet, Kevin A.G., David, Aurelien, & Whitehead, Lorne.

    (2016). Why color space uniformity and sample set spectral

    uniformity are essential for color rendering measures, 12(1-

    2), 39-50. doi: 10.1080/15502724.2015.1091356

    • David, Aurelien, Fini, Paul T., Houser, Kevin W., Ohno, Yoshi,

    Royer, Michael P., Smet, Kevin A. G., . . . Whitehead, Lorne.

    (2015). Development of the IES method for evaluating the

    color rendition of light sources. Optics Express, 23(12), 15888-15906. doi: 10.1364/OE.23.015888

    • IES. (2015). IES-TM-30-15: Method for Evaluating Light

    Source Color Rendition (pp. 26). New York, NY: The

    Illuminating Engineering Society of North America.

    Questions & comments ?

    http://www.cie.co.at/index.php?i_ca_id=1027