1 Power Quality Analysers
1.1 GridSense Powermonic
1.1.1 Introduction The PowerMonic range of portable power recorders offers comprehensive and reliable monitoring of low voltage circuits. Built with high performance, toughness and focus on ease of use, the PowerMonic has been adopted as the workhorse instrument for a variety of power monitoring applications including power quality analysis, supply compliance checks, power flow studies, energy audits and voltage investigations. The PM45 is the latest addition to the PowerMonic product line, meeting CATIV-600V safety certification and voltage measurement standards. With four voltage and current channels, the PM45 records a trend over time along with a range of power quality parameters, including flicker, harmonics, power and imbalance in accordance to the latest IEC standards. The PM45 is also an independent event recorder capturing high resolution snapshots of fluctuations including motor starts, spikes and transients based on voltage and current limit settings. Utilized for short and long term power monitoring applications, the PM45 is typically installed on pad mount and pole mount transformers, capacitor banks, regulators, distribution substations, as well as commercial, residential and industrial connection points. Since its introduction in 1995, the PowerMonic has proven to be a reliable and versatile everyday instrument used worldwide by System Planners, Distribution Engineers, Electrical Engineers, Electrical Contractors, Power Quality Engineers, and Maintenance Engineers alike.
1.1.2 Key Features
Up to eight (8) input channels [four (4) voltage and four (4) current]
Power profiling with high-speed event capture
Transient and harmonic analysis, flicker and unbalance
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831
1.2 SUIN SA2100
1.2.1 Introduction The SUIN SA2100 is a comprehensive and cost effective instrument ideally suited for the electrical trades toolbox and intended to monitor your electrical supply and diagnose Power Quality issues on-site and in real-time. It is battery operated and therefore offers the flexibility of a handheld multi-meter.
1.2.2 Key Features
Safety: CAT III 1000V / CAT IV 600V
Standards: IEC61000-4-30 (2008) S class EN50160 (2007)
Single-phase 2 W / Single-phase 3 W / 3-phase 3 W / 3-phase 4 W
Monitors four (4) voltages and currents
Display: Run Chart, Bar Chart, Vector Graphic, Waveform, Event List, Readings
Harmonics and interharmonics, flicker, transient capture, three-phase unbalance (voltage and current), dips and swells, voltage rapid change, and interruption
LAN interface PC can keep real-time remote communication
Built-in 8G memory card, USB port, LAN port for real-time remote control functionality and data download
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831
1.2.8 Specifications
Measurement Range Resolution Accuracy
Voltage/Current/Frequency
Channel 3-phase line input + 1 neutral line input
Vrms(dc+ac) 1 ~ 1000Vrms 0.1Vrms ±5%
Vpk 1 ~ 1400Vpk 0.1Vpk ±5%
V(CF) 1.0 ~ >2.8 0.01 ±5%
Arms 1~ 3000A 1A ±1% ± 5digits
1~ 300A 0.1A ±1% ± 5digits
Apk 1 ~ 4000Apk 1A ±1% ± 5digits
A(CF) 1 ~ 10 0.01 ±5%
Frequency 42.5~57.5Hz(50Hz nominal) 0.01Hz ±0.01%
51~69Hz(60Hz nominal) 0.01Hz ±0.01%
Dips & Swells
Vrms1/2 0 ~ 200% of nominal voltage
0.1Vrms ±1%
Arms1/2 1 ~ 3000A 1A ±1% ±5 counts
1 ~ 300A 0.1A ±1% ±5 counts
Threshold levels Programmable thresholds in percent of nominal voltage Event detection based upon ½ cycle rms voltages Captures Dips, Swells Interruptions and Rapid Voltage Changes
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831
1.3 ZES Zimmer LMG500
1.3.1 Introduction The ZES Zimmer LMG500 is a 1 to 8 Channel Precision Power Analyser.
The LMG500 is best-in-class for measurements of:
Devices, e.g. E-machines, frequency inverters, and transformers;
Installations and associated elements;
Power grids and consumer electrical networks to determine interactions; and
Components, e.g. ferrite cores, semiconductors, and capacitors. Other applications include:
CE compliance tests on devices;
Analysing the feedback of harmonics and flicker (load variations); and
Standby power consumption.
1.3.2 Key Features The most important features of the LMG500 are:
Wide dynamic measuring range from 3V to 1000V/3200Vpeak, 20mA to 32A/120A peak in direct measurement only by a single pair of sockets for each voltage and current input;
Modular with 1 to 8 power measuring channels;
Measuring accuracy at 45 to 65Hz 0.015% of reading plus 0.01% of range;
3MSample/s per channel, absolutely gapless sampling with the evaluation of all sampling values;
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831
2 Logging Instruments
2.1 Load Logger
2.1.1 Introduction
Load Logger measures AC current (load) and is ideal for monitoring loads on circuits and switchboards to record load profiles that can be used to identify slow changing events such as long duration interruptions, outages and derive estimates of usage patterns. Load Logger is also useful as a diagnostic tool to assess load sharing and load balancing on single and three phase systems. Some common monitoring applications include: ac motors and pumps for pool, irrigation, lighting, data centres, air conditioning equipment and switchboards.
2.1.2 Specifications
PARAMETER MULTI-CHANNEL
Input Channels Current Inputs (RMS) Scalable up to 4 channels - Phases A, B, C and Neutral Temperature Inputs (optional) 2 x PT1000 RTD Communications
Serial Data (standard) RS232 (115.2 kbps)
Wireless (optional) Bluetooth
Logging Logged Data Memory MicroSD Logging Interval Programmable from 1 minute Measurements Current (RMS), Max. Current (RMS), Current Unbalance,
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831
Temperature Accuracy ±0.5% (excludes current sensor) System Accuracy ±1% (clamp-on current sensor) Outputs Visual Tools Graphical Interface Data File CSV format Visual Indicator 2 x Status LED Digital 2 x Latched Relays (optional) General
Display (optional) LCD: Measurements and Max. Current time
Current Sensors Flexible current or clamp-on current probes - Automatic detection
Power Supply Non-rechargeable battery with External DC option
Battery Life 1 year (@ 5min. non-aggregated logging
Safety Category IEC 61010-1,CAT IV 600V defined by CT
Physical Dimensions (H x W x L) 55 x 90 x 115 mm Weight 390g (battery included) Material and Colour Polycarbonate, moulded in light grey Operating Temperature -20°C to 85°C Degree of Protection IP65, NEMA 4
2.1.3 Installation
The logger can be installed using a mix of clamp-on current and flexible current probes and automatically detects each sensor type.
2.1.4 Software
Configuration software included.
2.1.5 Calibration
Each Load Logger is factory calibrated. The calibration values are saved in the initial configuration file.
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831
3 Remote (Online) Monitoring Systems
3.1 Load Remote Load Remote is a Remote Terminal Unit (RTU) that measures AC current in up to five (5) circuits and facilitates on-line monitoring. All data is transmitted back to a secure database utilising modern communication networks with programmable intervals. The user is provided with a web login and password and able to quickly retrieve, view and download data on-line.
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831
Load Remote is also useful as a diagnostic tool to assess load sharing and load balancing on single and three phase systems. Load Remote is intended for applications requiring long term monitoring and where periodic site visits may not be feasible or access is difficult.
Some common monitoring applications include: ac motors and pumps for pool, irrigation, lighting, data centres, air conditioning equipment and switchboards.
Digital inputs/outputs and alarm thresholds available for control and condition monitoring applications. This product can be customised to your specific requirements.
PARAMETER SPECIFICATION
General electrical Rated load current Up to 3000A. Working voltage 600V as defined by current sensor. Power source External 12V DC. Channels AC current
(1) AC current, up to five (5) channels or circuits.
Temperature (2)
Optional: Temperature inputs. Combinations of (1) and (2) totalling five channels.
GSM/GPRS (900MHz/1800MHz). Device communications RS-232 for programming Data Pitching Programmable transmit interval 1 minute minimum Physical Dimensions (H x W x D) 171 x 121 x 55 mm Material Polycarbonate, moulded in light grey Rating IP65, NEMA4 Operating temperature -20°C to 70°C
Load Remote can be packaged into a suitable enclosure to meet your requirements and with various current probes. 3.2 Monitoring Back-Up Generators OmniMetrix is a leader and pioneer in wireless remote monitoring, control and diagnostics for emergency power generator systems. With over 15 years of experience and thousands of monitored generators, OmniMetrix is the proven solution for making emergency power systems more reliable. The OmniMetrix system is currently installed globally on a wide range of critical facilities, including cell towers, grocery stores, medical facilities, data centers and public transportation systems, as well as federal, state and municipal government facilities. As a system that facility maintenance teams have described as vital, we get better information to the right people faster. OmniMetrix’s robust M2M (machine to machine) 24/7 monitoring system increases the reliability of your generators by eliminating 95% of all Fail-to-Start situations. Cost-effective monitors connect to all major brands of generators and are Modbus compatible.
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831
4 Current Probes and Sensors
4.1 Flexible Current Sensors
PARAMETER 1AFF3000-6 (3000A)
(use with PM35)
SAF3000_6B (3000A)
(use with PM45)
Electrical Rated Input Current 3000A 3000A Calibrated Output @ 1000A 50Hz 78mV 78mV Load resistance 4.5KΩ 4.5KΩ Bandwidth 10Hz to 20kHz 10Hz to 20kHz Accuracy (@ 25°C, 50Hz) ± 0.5% of reading ± 0.5% of reading Linearity (10% to 90% of range ± 0.2% of reading ± 0.2% of reading Phase Error (45Hz - 65Hz) ± 1° ± 1° Position Sensitivity ± 2% of reading ± 2% of reading Temperature Coefficient ± 0.05% of reading / °C ± 0.05% of reading / °C External Field (with cable >100mm from the head)
± 0.25% of range ± 0.25% of range
Working Voltage 1000V AC or DC 1000V AC or DC General Probe and Cable Material Alcryn 2070 NC double
Operating Temperature Range -20°C to +65°C -20°C to +65°C Storage Temperature Range -40°C to +75°C -40°C to +75°C Operating Humidity 15% to 85% (non-condensing) 15% to 85% (non-condensing) Degree of Protection IP65 IP65 Colour Probe: Green RAL6018 Probe: Green RAL6018
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831
PARAMETER 1ACF3000-6 (3000A)
(use with PM35)
1AF3000-6 (3000A)
(use with PM45)
Electrical Maximum Measureable Current 100kA at (50/60)Hz 100kA at (50/60)Hz Internal Resistance 30Ω per 400mm 30Ω per 400mm Accuracy ± 1% (Calibrated) ± 1% (Calibrated) Linearity ± 0.2% (Calibrated) ± 0.2% (Calibrated) Output Signal (Sinusoidal) 100mV/KA @ 50Hz 100mV/KA @ 50Hz Frequency Range 20Hz to 5kHz 20Hz to 5kHz Position Sensitivity ± 2% maximum ± 2% maximum Influence of External Field ± 2% maximum ± 2% maximum Temperature Coefficient ± 0.07% per °C ± 0.07% per °C Working Voltage (max.) 1000V at (50/60)Hz 1000V at (50/60)Hz Safety Category (IEC 61010-1) 1000V CAT III / 600V CATIV 1000V CAT III / 600V CATIV High Voltage Withstand 7400VAC (50/60)Hz for 1 minute 7400VAC (50/60)Hz for 1 minute Dimensions Cable length 2m 2m Coil Inside Diameter A 170mm 170mm Coil Outside Diameter B 201mm 201mm Coil Length C 600mm 600mm Cap Coupling cross section D 18mm (min.) 18mm (min.) Cap Coupling cross section E 23mm (max.) 23mm (max.) Coil cross-section F 15.5mm 15.5mm Materials Transducer and cable Thermoplastic RUBBER, flame
retardant UL 94 V-O rated Thermoplastic RUBBER, flame retardant UL 94 V-O rated
Couplings Polypropylene UL 94 V-O rated Polypropylene UL 94 V-O rated Colour (transducer) Blue Blue Colour (Cable and couplings) Black Black Cable 1000V UL Style 20940;
Diameter: 5.5mm - wires 2 x 24AWG
1000V UL Style 20940; Diameter: 5.5mm - wires 2 x 24AWG
Shield 85% coil, 100% output cable 85% coil, 100% output cable Environmental Working Temperature -20°C to +70°C -20°C to +70°C Relative Humidity 85% (non-condensing) 85% (non-condensing) Pollution Degree 2 2 Maximum Altitude 2000m 2000m
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831
4.2 Clamp on Current Sensors
PARAMETER 1AC10 (10A)
(use with PM45)
1ACR100S (100A)
(use with PM35)
1AC100S (100A)
(use with PM45)
General electrical Rated Input Current 10A. 100A. 100A. Maximum Input Current 15A. 150A. 150A. Output Signal 440mV @ 10A. 440mV @ 100A. 440mV @ 100A. Burden Included 2.2 Ω (external) Included Accuracy ±1.0% ±1.0% ±1.0% Frequency Range 45Hz - 5000Hz 45Hz - 5000Hz 45Hz - 5000Hz Dielectric Strength 3000V @ 60Hz for 1
minute 3000V @ 60Hz for 1 minute
3000V @ 60Hz for 1 minute
Working Voltage Bare conductor: 30V; Insulated conductor: 600V
Bare conductor: 30V; Insulated conductor: 600V
Bare conductor: 30V; Insulated conductor: 600V
Physical Dimensions (H x W x L) (90.5 x 41.2 x 23.8) mm (90.5 x 41.2 x 23.8) mm (90.5 x 41.2 x 23.8) mm Jaw Aperture (14.3 x 15.9) mm (14.3 x 15.9) mm (14.3 x 15.9) mm Weight 113 grams (excluding
lead and connector) 113 grams (excluding lead and connector)
113 grams (excluding lead and connector)
Colour Grey / light grey Grey / light grey Grey / light grey Safety Class Class III per IEC 61010-
1 Class III per IEC 61010-1
Class III per IEC 61010-1
Operating temperature -20°C to 50°C -20°C to 50°C -20°C to 50°C Relative Humidity 85% (non-condensing) 85% (non-condensing) 85% (non-condensing)
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831
PARAMETER 1ACR100 (100A)
(use with PM35)
1ACR500 (500A)
(use with PM35)
1ASC500 (500A)
(use with PM45)
General electrical Rated Input Current 100A 500A 500A Maximum Input Current 120A 650A 650A Output Signal 440mV @ 100A. 440mV @ 500A. 440mV @ 500A. Burden Included Included Included Accuracy (Ratio Error) Better than ±1.0% Maximum Error (Ratio Error)
1% accuracy from 20% to 125% of rated current
1.5% @ 5% and 0.5% @110% of rated current
1.5% @ 5% and 0.5% @110% of rated current
Phase Error <0.36 degrees at rated current
Maximum Burden 15VA 15VA 15VA Accuracy Class 0.5M AS1675 0.5M AS1675 0.5M AS1675 Double Insulation 300V AC RMS 300V AC RMS 300V AC RMS Frequency Range 40Hz - 5000Hz 5Hz - 5000Hz; 0.5%
Working Voltage 650V 650V 650V Physical Dimensions (H x W x L) (99 x 210 x 60) mm (99 x 210 x 60) mm (99 x 210 x 60) mm Jaw Aperture 52 mm 52mm 52mm Weight 750 grams (excluding
lead and connector) 750 grams (excluding lead and connector)
750 grams (excluding lead and connector)
Encapsulation / Colour Fully insulated / Black Fully insulated / Black Fully insulated / Black Safety Class CAT III per IEC 61010-
1 CAT III per IEC 61010-1
CAT IV per IEC 61010-1
Operating temperature -10°C to 50°C -10°C to 50°C -10°C to 50°C
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831
4.4 Substation Current Transformer Converters
4.4.1 Introduction
CK1: 1 Amp Substation CT Converter CK5: 5 Amp Substation CT Converter The CK1 or CK5 Powermonic Current Transformer (CT) Converter is a three phase device that transforms the standard 1A or 5A secondary current from a CT to a 200 mA output current suitable for direct connection to a Powermonic CT input. Internal protection is provided to enable the output leads to be disconnected from the Powermonic without affecting the CT secondary circuits. The units are designed for high accuracy and therefore lend themselves for Metering and Power Quality applications.
4.4.2 Specifications
PARAMETER CK1 (1A to 200mA) CK5 (5A to 200mA)
Electrical Rated Input Current 1A 5A Rated Output Current 200mA 200mA Accuracy Class 0.5M (AS1675) 0.5M (AS1675) Working Voltage 1000V AC or DC 1000V AC or DC General Input Connections Red, White and Blue banana
sockets Red, White and Blue banana sockets
Output Connections Colour coded 1.8m leads with 4 pin connectors to suite PM20, PM30, PM30+, PM40
Colour coded 1.8m leads with 4 pin connectors to suite PM20, PM30, PM30+, PM40
Enclosure Light grey polycarbonate Light grey polycarbonate Weight 4.4kg 4.4kg Dimensions (W x L x D) (140 x 230 x 100) mm (140 x 230 x 100) mm Including glands and sockets (140 x 280 x 100) mm (140 x 280 x 100) mm
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831
5.1 Metering
5.1.1 Measuring - PVC The SES range of PVC tape insulated metering CTs are designed and manufactured to cater for wide range of applications. They are tested to IEC 60044-1 2003-02 and are certified to ASTA and CE mark Certified to UL. The standard rated secondary current is 5A.
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831
5.1.2 Measuring - MBQ Series MBQ series current transformers are ideally designed for bus bar mounting and find applications in measurement, test and control of electrical equipment. The MBQ current transformer is housed into a case of PPO flame retardant material.
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831
5.1.3 Measuring - MSQ Series MSQ series current transformers are ideally designed for bus bar mounting and find applications in measurement, test and control of electrical equipment. The MSQ current transformer is housed into a case of PPO flame retardant material. FEATURES:
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831
5.2 Protection
5.2.1 Protection - PVC The SES range of PVC tape insulated Protection CTs are designed and manufactured to cater for wide range of applications. They are tested to IEC 60044-1 2003-02 and are certified to ASTA and CE mark Certified to UL. The standard rated secondary current is 5A.
Ratio Class 10P5 15VA Class 10P10 15VA Class 5P10 15VA
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831
5.3 Special Purpose
5.3.1 Summation Current Transformer When the current in a number of feeders need not be individually metered but summated to a single meter or instrument, a summation current transformer can be used. In consumer installation, where there is more than one feeder, it is more economical to use summation metering and for this purpose, summation Current Transformer (CT) is required. The summation CT consists of two or more primary windings which are connected to the feeders to be summated, and a single secondary winding which feeds a current proportional to the summated primary current. A typical ratio would be 5 + 5 + 5 / 5A, which means that three primary feeders of 5 Amps are to be summated to a single 5 Amps meter. We can custom-design to your specific requirements.
5.3.2 Interposing Current Transformer Interposing types can be used to modify the secondary current from an existing line CT. This is useful for modifying secondary currents without replacing the line CTs. The main function of an interposing CT is to balance the currents supplied to the relay where there would otherwise be an imbalance due to the ratios of the main CTs. Interposing CTs are equipped with a wide range of taps that can be selected by the user to achieve the balance required.
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831
As the name suggests, an interposing CT is installed between the secondary winding of the main CT and the relay. They can be used on the primary side or secondary side of the power transformer being protected, or both. Interposing CTs also provide a convenient method of establishing a delta connection for the elimination of zero sequence currents where this is necessary.
5.3.3 Core Balance Current Transformer
Core balance current transformers are intended for providing a very sensitive method of earth leakage protection on three-phase electrical systems with suitable relays. Cables of all phases pass through the inner diameter of the transformer and there is no output under no-fault conditions. In the event of an earth-fault a non-zero current exist and induces a changing magnetic field within the core, which in turn generates a secondary voltage which operates a relay (via burden).
We can optimally custom-design to your specific requirements based on relay types and settings, and the required primary operating current.
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831
6 Medium Voltage Products
6.1 Monitoring Products
6.1.1 Cable Mounted Sensor The LIQ60 is an intelligent transmission and distribution overhead line monitoring system and can provide:
Continuous monitoring and capture of critical performance data on overhead network lines up to 138kV;
Time-stamped event recordings;
Line status, fault waveform, outages, load profile, ambient and conductor temperatures, voltage sensing, displacement power factor, voltage reading (with an external insulated resistor);
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831
6.1.2 Pole Mounted Sensor
The LIQ35 is a reliable pole mounted solar powered line fault indicator (with battery backup) for use on three phase three wire, and SWER overhead line systems. The LIQ35 utilises a fault detection algorithm that adapts to network parameters and requires no configuration. Key features include:
Continuous fault indication;
Fault types: Permanent faults; Transient faults; Outage events; Closure events; Self-clearing faults (fault current without loss of voltage);
Patented adapting fault algorithm;
Dual magnetic field sensors for improved fault capture;
Voltage sensing to accurately identify outages and trips;
Time and data stamped event recording;
Recognition of line voltage return;
Two visual indicators displaying line status and most recent fault;
Inrush restraint to ensure only real faults are reported;
SCADA protocol compatible (DNP3); and
Advanced programmable options for maximum flexibility. Key specifications include:
Line voltage: 5kV to 145kV;
Rechargeable batteries: 4 x 2V, 2.5Ah Sealed lead-acid
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831
6.2.6 Outdoor Metering Units
6.3 Indoor and Outdoor Current Transformers
6.3.1 Indoor Ring Type, Window Type and Bus Duct (up to 36kV)
Typically for currents of 200A and above - depending on burden and accuracy requirements.
Inner diameters from 65 mm to 170 mm available for ring type, and up to (110 x 75) mm for window type.
Pigtail is provided for CTs of rating 6.6 kV and above, and should be connected to the primary bar to obtain an equi-potential (discharge-free) connection.
Large diameter bus duct CTs are available, suitable for up to 30000 A.
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831
7 Power Quality Mitigation Products
7.1 Reactors and Filters We can source appropriate line side and load side reactors and filters to address the identified causes of poor power quality. 7.2 Power Factor Correction Units We work with local manufacturers and suppliers to provide appropriately sized PFC units. We can custom design to your requirements and also offer a segregated design that not only enables more efficient service and maintenance but also ensures the sensitive control components are not affected by heat generated by the harmonic blocking reactors and hence prolonging the life of the equipment.
Up to 100kVar Wall Mount Cubicle 1000H x 800W x 300D (wall mount cubicle without reactor segregation) Up to 250kVar Cubicle 2000H x 800W x 600D (expandable to 300kVar if no isolator or circuit breaker required) Up to 550kVar Cubicle 2000H x 1250W x 600D (expandable to 600kVar if no isolator or circuit breaker required) Up to 800kVar Cubicle 2000H x 2050W x 600D (expandable to 900kVar if no isolator or circuit breaker required) Up to 1000kVar Cubicle 2000H x 2500W x 600D Switched Capacitor Bank: Thyristor controlled switching technology - mitigates the effects of fast switching loads (lifts, welding equipment, oil and gas drilling rigs; and mine site drilling equipment).
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831
7.3 Active Harmonic Filtering Wall-Mounted Active Filter ADF P100 The ADF P100 is an ultra-efficient, easy to use solution in a wall mounted cabinet. The tall and narrow design allows installation where space is at a premium. It has a nominal current of 70 to 100 A RMS and is available in the voltage range 208 - 480 V RMS nominal. ADF P200 Active Filter The ADF P200 is a very fast active filter and can eliminate harmonic problems up to the 100th harmonic and works well in even very resonant grids. It is suitable for mitigating resonances, interharmonics and high frequency disturbances. ADF P300 Active Filter The ADF P300 is suitable for commercial and industrial loads.
STATCOM (Static Synchronous Compensator)
Is a shunt device, which uses force-commutated power electronics (i.e. GTO, IGBT) to
control power flow and improve transient stability on electrical power networks.
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831
ADF P700 STATCOM: The ADF P700 is a high power, utility grade, medium voltage STATCOM for heavy industrial loads. It is useful for dynamic reactive compensation, flicker mitigation, and harmonic suppression in applications such as electric arc furnaces, cranes, hoists and wind farms. The ADF P700 is available in modular 3 MVA or 6 MVA compensation power. Several units can be operated in parallel to achieve higher power levels.
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831
8 Consulting and Services
8.1 Consulting in Power Quality
8.1.1 Power Quality Investigation
This includes:
Site Survey
Site Monitoring
Data Analysis and Identification
Reporting and Recommendations
8.1.2 Power Quality Mitigation
Following the Power Quality Investigation, we then propose solutions to mitigate the contributing aspects to poor power quality. This includes proposing products and equipment followed by further monitoring for validation.
8.1.3 Power Quality Management
Your electrical distribution system may be changing - growing (adding more elements to do more work). In this case we would recommend a Power Quality Management Plan for continuous monitoring and assessment.
8.2 Training
8.2.1 Product Training
Product training is provided on all electronic monitoring products and customised equipment sold and or designed by CHK Power Quality Pty Ltd.
8.2.2 Professional Training
A single day course is offered in Power Quality with a certificate awarded upon completion. The course covers an overview of power systems in Australia, introduces concepts of power quality, monitoring and reporting and how to improve power quality.
8.3 Technical Support
8.3.1 Product Support
Product support is provided on all electronic monitoring products and customised equipment sold and or designed by CHK Power Quality Pty Ltd and some products designed by GridSense; please enquire.
8.3.2 Calibration and Repairs
We have a service department that provide repairs and calibration for our electronic products.
Address: Unit 102, 25 Angas Street Telephone: +61 2 8283 6945 Meadowbank NSW 2114, Sydney Australia Fax: +61 2 8212 8105 Website: www.chkpowerquality.com.au ABN: 53 169 840 831
8.4 Low Volume Contract Manufacturing
We have over fifteen years of experience in low volume production. Items include: wire looms; leads and probes; building electronic circuit boards (hand soldering) and product sub-assemblies.
8.5 Engineering and Project Management Services
8.5.1 Feature Requests and New Features
Where possible, we can update a product to include a specific feature to address your requirement.
8.5.2 Design
Our engineering team can custom-design a solution (involving industrial design, electronic, firmware and software development) and manage the whole product development cycle, from specification to testing and approvals.