ChevronTexaco Energy Technology Co. QR-1 April 2005 Quick Reference Guide Contents Page Introduction QR-2 Contacts QR-3 Facilities for Analyzing Lead in Coatings Coating Manufacturers Suppliers Steps to Coating System Selection QR-7 System Number Selection Guide QR-8 Atmospheric Coatings for On- & Offshore Coatings for Concrete Coatings Under Insulation & Fireproofing Internal Vessel Coatings Water-based Coatings Coating Compatibility Chart QR-11 Coating System Data Sheets QR-12 List of Available System Data Sheets System Data Sheets Acceptable Brands by Generic Classification Acceptable Brands by Manufacturer
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Quick Reference Guide
Contents Page
Introduction QR-2
Contacts QR-3
Facilities for Analyzing Lead in Coatings
Coating Manufacturers
Suppliers
Steps to Coating System Selection QR-7
System Number Selection Guide QR-8
Atmospheric Coatings for On- & Offshore
Coatings for Concrete
Coatings Under Insulation & Fireproofing
Internal Vessel Coatings
Water-based Coatings
Coating Compatibility Chart QR-11
Coating System Data Sheets QR-12
List of Available System Data Sheets
System Data Sheets
Acceptable Brands by Generic Classification
Acceptable Brands by Manufacturer
ChevronTexaco Energy Technology Co. QR-1 April 2005
IntroductionThis Quick-Reference Guide from Chevron's Coatings Manual has been designed to give you easy access to the selection process for certain types of coating projects:
• Atmospheric (both on- and offshore)
• Concrete (mild environment only)
• Internal vessel
• Under insulation and fireproofing
By following the coating selection process, you will find a system data sheet which details the specifications and approved manufacturers for the coatings that fit your project. (See sample system data sheet below.) The design of the data sheet simpli-fies your preparation of a selection-and-specification package for a coating contractor: just photocopy the appropriate data sheet(s) and specification(s).
Note The system data sheets outnumber the references to coating systems in the selection criteria because Chevron has many coating systems in use.
Do not choose a coating system unless you have been directed to do so by following either:
• The selection guide in this publication.• Instructions from one of the Company's coating specialists or a coating
manufacturer.
Also included in this Guide, the Coatings Compatibility Chart is a resource for projects involving maintenance coatings.
For questions about the Guide, contact the CRTC specialists listed on the Contacts page.
Sample of a System Data Sheet
SYSTEM DATA SHEETCoatings Manual Chevron Corporation
» Non-catalyzed silicones remain tacky until exposed to heat above 300°F to 400°F.* Thumalox 230C topcoat will go over ONLY Thurmaloc 245C Silicone Zinc Dust Primer.
Ameron PSX 892HS • 324Carboline Thermaline 4631WB • 108Dampney Thurmalox 230C* 360Devoe HT-12 572Hempel 5690 400Hempel 5691 586International Intertherm 230 612PPG Industries Pittherm High Heat Silicone 554Sherwin Williams Aluminum 100-A-518 420Sherwin Williams Black 880-B-001 514Sigma Sigmatherm 5267 600Valspar 37-A-1 599
TOPCOAT
Silicone - High Temp Rated to 700°F
1.5 - 2.5 mils DFT
April 2005 QR-2 ChevronTexaco Energy Technology Co.
Coatings Manual—Quick Reference Guide Contacts
Contacts Facilities for Analyzing Lead in Coatings
Clayton Environmental Consultants 800/294-1755 22345 Roethel Drive Novi MI 48375
Forensic Analytical Specialties 800/827-3274 3777 Depot Road, Suite 409 Hayward CA 94545
Coating Manufacturers Manufacturers of Atmospheric and Internal Vessel Coatings
Ameron 714/529-1951 201 North Berry Street Brea CA 92621
Ashland Chemical 800/643-1234 1851 E. First Street, #700 Santa Ana CA 95705-4017
Carboline 314/644-1000 350 Hanley Industrial Court St. Louis MO 63144
Choose a system numberby type of surface, service,voc units.
Locate the correct data sheet by system number
ChevronTexaco Energy Technology Co. QR-7 April 2005
System Number Selection Guide Coatings Manual—Quick Reference Guide
System Number Selection GuideNote Pick a coating system number from one of the following tables then find that number in the System Data Sheets for Coating Systems.
For coatings under insulation & fireproofing, see chart next page.
Atmospheric Coatings for On- & Offshore (1 of 2)
Type of Equipment
OnshoreOff-
shoreStd Hi Perf
Code C/E: Vessels & Heat Exchangers
Uninsulated below 200°F 2.2 3.1 3.1
Uninsulated to 200°F and steamed out 2.6 3.1 3.1
Uninsulated 200–600°F N/R 2.4 2.4
Uninsulated 300-600°F 2.4 N/R N/R
Code D: Tanks
Uninsulated to 200°F 2.2 3.1 3.1
Wind girders 2.2
3.1 N/RFloating roofs (Uninsulated) 2.6
Stairways & railings 2.2
Code F: Furnaces
Structural steel & platforms 2.6 2.6N/R
Stacks, breeching, furnace body to 600°F 2.4 2.4
Code G/K: Pumps, Turbines, Compressors & Drivers
Uninsulated to 200°F N/R 3.8 3.8
Uninsulated 200–600°F 2.4 2.4 2.4
MotorsN/R
3.8 3.8
Externally insulated exhaust ducts N/R 1.4
Code J: Instruments
Field instrument panels (steel) 2.2 2.6 3.1
Weatherproof housings (steel)N/A N/A
3.1
Instrument tubing (stainless)N/R
Instruments (galvanized or aluminum) N/R N/R
Code L: Piping (including Valves & Fittings)
Uninsulated to 200°F 2.2 3.1 3.1
Uninsulated below 200°F steamed out 2.6 3.1 3.1
Uninsulated 200–600°F 2.4 2.4 2.4
April 2005 QR-8 ChevronTexaco Energy Technology Co.
Coatings Manual—Quick Reference Guide System Number Selection Guide
(1) Moderate coating loss due to abrasion, light equipment wear. Possibility of impact on coating.(2) Crude oil, jet fuel, gasoline, etc.(3) Severe coating loss due to abrasion, heavy equipment wear. Definite potential for impact on coating.(4) No coating loss due to abrasion, possible light foot traffic. No physical impact on coating
ChevronTexaco Energy Technology Co. QR-9 April 2005
System Number Selection Guide Coatings Manual—Quick Reference Guide
Coatings Under Insulation & Fireproofing
SubstrateExposure to Temperature Temperature(1) Coating System
Carbon Steel Continuous -50°F to 140°F 12.1
Continuous 140°F to 300°F 12.2
Cyclic (produce wet/dry conditions) 12.3
Continuous Above 300°F Do not coat
Special Conditions Above 300°F 12.7
Stainless Steel Continuous -50°F to 140°F 12.4
Continuous 140°F to 300°F 12.5
Cyclic (produce wet/dry conditions) 12.6
Continuous Above 300°F 12.7
(1) Actual temperature of steel not design temperature.
Internal Vessel Coatings
ServicesNon-Reinforced
Thin Film
ReinforcedGlass Flake Laminate
High Temperature/Pressure
High Temperature/ Cathodic
High Temperature/ Non Cathodic
High Pressure/ Non Cathodic
Fresh Water 8.1 9.1 10.1
Demineralized Water 8.2 9.2 10.2 11.2 11.2.1
Potable Water 8.3 9.3 N/R
Salt Water & Brine 8.4 9.4 10.4 11.4 11.4.1 11.4.2
Notes:YES: Applied coating will not lift, wrinkle, blister; will have reasonable bond; check in field with a test patch.LTD: Some formulae are compatible; some not. Consult manufacturer.N/R: Not recommended1 Durability and use depend on type of lacquer.2 Must apply topcoat before coated surface has hardened.3 Gloss on paint being overcoated must be removed by weathering or sanding.4 Topcoat may blister if high-solvent topcoat applied too thickly, too quickly.
ChevronTexaco Energy Technology Co. QR-11 April 2005
Coating System Data Sheets Coatings Manual—Quick Reference Guide
Coating System Data Sheets
Available System Data Sheets
Primer Only Systems1.1 Inhibited Alkyd (Primer Only)1.2 Silicone Alkyd (Primer Only)1.3 Self-Cured Inorganic Zinc–Solvent Reducible (Primer Only)1.3.1 Self-Cured Inorganic Zinc–Water Reducible1.4 Polyamide Epoxy (Primer Only)1.5 Amine Adduct Epoxy (Primer Only)1.6 Organic Zinc-Rich Primer for Galvanizing Repair1.7 Vinyl Butyral Wash Primer1.8 Epoxy Mastic–Surface-Tolerant Prime1.8.1 Epoxy Mastic–Surface-Tolerant Primer–Aluminum Color Only1.9 Temperature-Indicating Paint
ChevronTexaco Energy Technology Co. QR-13 April 2005
Coating System Data Sheets Coatings Manual—Quick Reference Guide
Non-Reinforced Thin Film Coatings for Immersion Service8.1 Non-Reinforced Thin-Film Coatings for Fresh-Water Immersion
Service8.2 Non-Reinforced Thin-Film Coatings for Demineralized Water or
Condensate Immersion Service8.3 Non-Reinforced Thin-Film Coatings for FDA-Approved Potable
Water Immersion Service8.4 Non-Reinforced Thin-Film Coatings for Salt Water and Brine Immer-
sion Service8.5 Non-Reinforced Thin-Film Coatings for Produced-Water Immersion
Service8.6 Non-Reinforced Thin-Film Coatings for Crude Oil (Sweet or Sour)
Immersion Service8.7 Non-Reinforced Thin-Film Coatings for Fuel (Low-aromatic) Immer-
sion Service8.8 Non-Reinforced Thin-Film Coatings for Fuel (High-Aromatic)
Immersion Service8.9 Non-Reinforced Thin-Film Coatings for Aromatic-Hydrocarbon
Immersion Service8.10 Non-Reinforced Thin-Film Coatings for Acetone Immersion Service8.11 Non-Reinforced Thin-Film Coatings for Ethyl & Methyl Alcohol
Immersion Service
Glass Flake Reinforced Coatings for Immersion Service9.1 Glass-Flake-Reinforced Coatings for Fresh-Water Immersion Service9.2 Glass-Flake-Reinforced Coatings for Demineralized Water or Conden-
sate Immersion Service9.3 Glass-Flake-Reinforced Coatings for FDA-Approved Potable Water
Immersion Service9.4 Glass-Flake-Reinforced Coatings for Salt Water and Brine Immersion
Service9.5 Glass-Flake-Reinforced Coatings for Produced Water Immersion
Service9.6 Glass-Flake-Reinforced Coatings for Crude Oil (Sweet or Sour)
Immersion Service9.7 Glass-Flake-Reinforced Coatings for Fuel (Low Aromatic) Immer-
sion Service9.8 Glass-Flake-Reinforced Coatings for Fuel (High Aromatic) Immer-
sion Service9.9 Glass-Flake-Reinforced Coatings for Aromatic Hydrocarbon Immer-
sion Service
April 2005 QR-14 ChevronTexaco Energy Technology Co.
Coatings Manual—Quick Reference Guide Coating System Data Sheets
Laminate Reinforced Coatings for Immersion Service10.1 Laminate-Reinforced Coatings for Fresh-Water Immersion Service10.2 Laminate-Reinforced Coatings for Demineralized-Water or Conden-
sate Immersion Service10.3 (reserved for future use)10.4 Laminate-Reinforced Coatings for Salt-Water Brine Immersion
Service10.5 Laminate-Reinforced Coatings for Produced-Water Immersion Service10.6 Laminate-Reinforced Coatings for Crude-Oil (Sweet or Sour) Immer-
sion Service10.7 Laminate-Reinforced Coatings for Fuel (Low Aromatic) Immersion
Service10.8 Laminate-Reinforced Coatings for Fuel (High Aromatic) Immersion
Service10.9 Laminate-Reinforced Coatings for Aromatic Hydrocarbon Immersion
Service
High-Temperature/High-Pressure Coating Systems11.1 (reserved for future use)11.2 Demineralized Water or Condensate Coatings Resistant to Tempera-
ture Gradients of 50°F & Compatible with Cathodic Protection11.2.1 Demineralized Water or Condensate Coatings Resistant to Tempera-
ture Gradients of 50°F & Incompatible with Cathodic Protection11.3 (reserved for future use)11.4 Salt Water & Brine Service Coatings Resistant to Temperature Gradi-
ents of 50°F & Compatible with Cathodic Protection11.4.1 Salt Water & Brine Service Coatings Resistant to Temperature Gradi-
ents of 50°F & Incompatible with Cathodic Protection11.4.2 Salt Water & Brine High Temperature/High Pressure Service Coatings
Resistant to Temperatures to 180°F, Pressures of 1000 PSI & Incompatible with Cathodic Protection
11.5 Produced Water Service Coatings Resistant to Temperature Gradients of 50°F & Compatible with Cathodic Protection
11.5.1 Produced Water Service Coatings Resistant to Temperature Gradients of 50°F & Incompatible with Cathodic Protection
11.5.2 Produced Water High Temperature/High Pressure Service Coatings Resistant to Temperatures to 180°F, Pressures of 1000 PSI & Incom-patible with Cathodic Protection
11.5.2 Crude Oil Service (Sweet or Sour) Coatings Resistant to Temperature Gradients of 50°F & Compatible with Cathodic Protection
ChevronTexaco Energy Technology Co. QR-15 April 2005
Coating System Data Sheets Coatings Manual—Quick Reference Guide
11.6.1 Crude Oil Service (Sweet or Sour) Coatings Resistant to Temperature Gradients of 50°F & Incompatible with Cathodic Protection
11.6.2 Crude Oil (Sweet or Sour) High Temperature/High Pressure Service Coatings Resistant to Temperatures to 180°F, Pressures of 1000 PSI & Incompatible with Cathodic Protection
Coatings Under Insulation & Fireproofing12.1 Under Insulation & Fireproofing—Non-Reinforced Thin Film Epoxy
Coatings for Continuous Carbon Steel Temperatures -50°F to 450°F12.4 Under Insulation & Fireproofing—Non-Reinforced Thin Film Epoxy
Coatings for Continuous Stainless Steel Temperatures -50°F to 450°F12.7 Under Insulation & Fireproofing—Non-Reinforced Thin Film Inor-
ganic Coatings for Carbon Steel or Stainless Steel Temperatures Above 450°F
(Series 13 through 19 Reserved for Future Use)
Concrete Coatings20.1 Epoxy Coatings for Concrete: Service Temperatures <140°F,
Moderate Physical Abuse, Intermittent & Continuous Exposure20.2 Epoxy Coatings for Concrete: Service Temperatures <140°F, Mild
Physical Abuse, Intermittent & Continuous Exposure20.3 Epoxy Coatings for Concrete: Service Temperatures <140°F, Aggres-
sive Physical Abuse, Intermittent & Continuous Exposure
Rivet and Seam Sealers 13.1 Rivet and Seam Sealers (Spray) - Epoxy13.2 Rivet and Seam Sealer (Trowel) - Epoxy13.3 Rivet and Seam Sealer - Isophthalic Polyester13.4 Rivet and Seam Sealer - Vinyl Ester13.5 Polysulfide Flexible Putty
April 2005 QR-16 ChevronTexaco Energy Technology Co.
SYSTEM DATA SHEET Coatings ManualChevron Corporation
1.1Inhibited Alkyd (Primer Only)
1.5 mils (max)
SSPC-SP6 (NACE No. 3) Commercial blast finish.
2.0 mils
Use this system.
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
Primer Only System
Ameron Amercoat 5105 • 336Carboline Carbocoat 115SG 408Devoe Devguard 4160 419Hempel Coatings (USA), Inc. Hempalin Primer 1205 415Hempel Coatings (USA), Inc. Hempalin Primer 1218 • 330International Interlac 260 • 300International Interprime 198 509Jotun Paints Cromoprimer 400Sherwin Williams Hi-Solids Alkyd Metal Primer B50NZ2 • 308Sigma Coatings Sigmarine Multiprimer 7117 390Sigma Coatings Sigmarine Primer ZP 7135 372Southern Coatings 94-258 Series • 336Tnemec Company Azeron Primer FD88 • 330Tnemec Company Versare Primer 4 342
PRIMERAlkyd - Inhibited
1.5 - 2.5 mils DFT
QRG - 1
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 3/17/2003
SYSTEM DATA SHEET Coatings ManualChevron Corporation
1.2Silicone Alkyd (Primer Only)
1.0 mils (max)
SSPC-SP6 (NACE No. 3) Commercial blast finish.
1.5 mils (min)
Use this system.
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 6/24/2004
SYSTEM DATA SHEET Coatings ManualChevron Corporation
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
Primer Only System
Keep inorganic zinc silicate mixed, using agitated pot while applying. See also System 1.3.1 (water reducible).
Ameron Dimetcote 9 491Ameron Dimetcote 9HS • 323Carboline Carbozinc 11 515Carboline Carbozinc 11 HS • 264Dampney Company, Inc. Thurmalox 215 • 274Devoe Catha-Coat 304V • 336Hempel Coatings (USA), Inc. Galvosil 15680 • 320Hempel Coatings (USA), Inc. Galvosil 1578 520International Interzinc 22 490International Interzinc 22HS • 340Jotun Paints Resist GTI 458PPG Industries Metalhide 1001 Primer 97-673/97-674 397Sherwin Williams Zinc Clad II B69V3/B69D11 462Sigma Coatings Penetrating Sealer SF 8353 • 48Tnemec Company SpanPrime IOZ 356 397Tnemec Company Tneme-Zinc 90-96 • 323
PRIMERSelf-Cured Inorganic
Zinc - Solvent Reducible
2.0 - 3.0 mils DFT
QRG - 3
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 6/24/2004
SYSTEM DATA SHEET Coatings ManualChevron Corporation
1.3.1Self-Cured Inorganic Zinc - Water Reducible
1.5 - 3.0 mils
SSPC-SP10 (NACE No. 2) Near-white blast finish.
6.0 mils (min)
Use this system.
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
Primer Only System
Keep inorganic zinc silicate mixed, using agitated pot while applying. See also System 1.3 (solvent reducible).
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 5/9/2002
SYSTEM DATA SHEET Coatings ManualChevron Corporation
1.4Polyamide Epoxy (Primer Only)
1.5 - 2.5 mils
SSPC-SP6 (NACE No. 3) Commercial blast finish.
3.0 mils (min)
Use this system.
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
Primer Only System
Where moisture will tend to collect under wet insulation (such as at insulation support rings) select Coating System 2.14.
Ameron Amercoat 385 • 276Carboline Carboguard 893 • 195Devoe Devran 224HS • 212Hempel Coatings (USA), Inc. Hempadur 4563 • 207Hempel Coatings (USA), Inc. Hempadur 45880 • 215International Interseal 670 HS • 240Jotun Paints Penguard HB 380PPG Industries 97-145 • 128Sherwin Williams Recoatable Epoxy Primer B67R5/B67V5 • 295Sigma Coatings Sigmacover Primer II 7413US • 300Sigma Coatings Sigmarite PC Unicoat 5483 PC • 252Tnemec Company Hi-Build Epoxoline 66 362Tnemec Company S.T. Typoxy N27 • 300
PRIMEREpoxy - Polyamide
3.0 - 4.0 mils DFT
QRG - 5
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 6/29/2004
SYSTEM DATA SHEET Coatings ManualChevron Corporation
1.5Amine Adduct Epoxy (Primer Only)
1.5 - 2.5 mils
SSPC-SP6 (NACE No. 3) Commercial blast finish.
3.0 mils (min)
Use this system.
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 6/29/2004
SYSTEM DATA SHEET Coatings ManualChevron Corporation
1.6Organic Zinc-Rich Primer for Galvanizing Repair
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
Primer Only System
Ameron Amercoat 68HS • 288Carboline Carbozinc 859 • 325Devoe Catha-Coat 313 • 282Hempel Coatings (USA), Inc. Zinc Primer 1649 593International Interzinc 280 • 100International Interzinc 52 • 336Jotun Paints Barrier • 294PPG Industries UC65147/97-674 • 336Sherwin Williams Zinc Clad 5 B69A45 488Sigma Coatings Sigmacover Zinc Primer II 7402 US • 300Tnemec Company Tneme-Zinc 90-97 • 320
PRIMERZinc-Rich -
Galvanizing Repair
3.0 - 4.0 mils DFT
QRG - 7
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 6/24/2004
SYSTEM DATA SHEET Coatings ManualChevron Corporation
1.7Vinyl Butyral Wash Primer
None
SSPC-SP1 Solvent Cleaning.
0.2 - 0.5 mils (min) (depending on manufacturer)
Use this system.
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:Surface Prep:
Total DFT:
Touch Up:
Primer Only System
Normally, we do not paint galvanized, aluminum, and stainless steel surfaces. If Chevron specifies or approves in writing the painting of such surfaces, then prepare the surface first with one coat of vinyl butyral wash primer before topcoating with the specified system. Topcoat the wash-primed surface within 24 hours with the system specified for the adjacent steel. Do not include the inorganic zinc primer when topcoating with Coating Systems 3.1 and 3.3. Do not exceed the manufacturer's recommended pot life for the vinyl butyral wash primer.
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 6/24/2004
SYSTEM DATA SHEET Coatings ManualChevron Corporation
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
Primer Only System
Available in colors. May use System 1.8.1 Aluminum-Filled Epoxy Mastic (Surface-Tolerant Primer) for better performance if aluminum color is acceptable.
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 5/9/2002
SYSTEM DATA SHEET Coatings ManualChevron Corporation
1.8.1Epoxy Mastic - Surface-Tolerant Primer - Aluminum Color Only
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
Primer Only System
System 1.8 is available in colors.
Ameron Amerlock 400 AL • 120Carboline Carbomastic 15 • 88Devoe Bar-Rust 239 • 119Hempel Coatings (USA), Inc. Hempadur 4588-1987 • 215International Interseal 670 HS • 240Jotun Paints Jotamastic 87 AL • 110PPG Industries UC65372/UC65373 • 118Sherwin Williams Epoxy Mastic Aluminum II B62S100/BV100 • 171Sigma Coatings TCP Aluminum 7477 • 240Tnemec Company Chembuild 135-1243 • 133
PRIMEREpoxy Mastic -
Surface Tolerant - Aluminum Filled
5.0 - 7.0 mils DFT
QRG - 10
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 5/9/2002
SYSTEM DATA SHEET Coatings ManualChevron Corporation
1.9Temperature-Indicating Paint
1.0 - 2.0 mils
SSPC-SP6 (NACE No. 3) Commercial blast finish.
2.0 mils (max)
Use this system.
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
Primer Only System
Case-by-case review of applications is required; time at temperature variations are substantial.
International Intertherm 715 550Tempil Temp-Alarm 126A 560
PRIMERTemperature-
Indicating Paint
1.0 - 2.0 mils DFT
VOC limits for these products vary from state to state. Check local regulations before using a product,
QRG - 11
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 5/2/2003
SYSTEM DATA SHEET Coatings ManualChevron Corporation
2.1Inhibited Alkyd | Alkyd Enamel
1.5 mils (max)
SSPC-SP6 (NACE No. 3) Commercial blast finish.
4.0 mils (min)
Use this system.
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
Two-Component Systems
Ameron Amercoat 5105 • 336Carboline Carbocoat 115SG 408Devoe Devguard 4160 419Hempel Coatings (USA), Inc. Hempalin Primer 1218 • 330International Interlac 260 • 300International Interprime 198 509Jotun Paints Cromoprimer 400PPG Industries 7-852 Series Industrial Primers 376Sherwin Williams Hi-Solids Alkyd Metal Primer B50NZ2 • 308Sigma Coatings Sigmarine Multiprimer 7117 390Sigma Coatings Sigmarine Primer ZP 7135 372Tnemec Company Azeron Primer FD88 • 330Tnemec Company Versare Primer 4 342
PRIMERAlkyd - Inhibited
2.0 - 3.0 mils DFT
Ameron Amercoat 220 • 180Ameron Amercoat 5405 • 327Carboline Carbocoat 139 • 240Devoe Devguard 4308 428Devoe Devguard 4348 • 340Hempel Coatings (USA), Inc. Hempalin Enamel 5214 410International Interlac 665 427Jotun Paints Pilot II 418PPG Industries 7-282 • 336Sherwin Williams Industrial Enamel B54Z Series 417Sherwin Williams Industrial Enamel VOC B54-Z Series • 309Sigma Coatings Sigmarine BTD 7238 345Tnemec Company Enduratone 23 341Tnemec Company Hi-Build Tneme-Gloss 2H 351
TOPCOATAlkyd Enamel
2.0 - 3.0 mils DFT
QRG - 12
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 3/17/2003
SYSTEM DATA SHEET Coatings ManualChevron Corporation
2.2Inhibited Alkyd | Alkyd Enamel | Alkyd Enamel
1.5 mils (max)
SSPC-SP6 (NACE No. 3) Commercial blast finish.
6.0 mils (min)
Use this system.
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
Two-Component Systems
Ameron Amercoat 5105 • 336Carboline Carbocoat 115SG 408Devoe Devguard 4160 419Hempel Coatings (USA), Inc. Hempalin Primer 1218 • 330International Interlac 260 • 300International Interprime 198 509Jotun Paints Cromoprimer 400PPG Industries 7-852 Series Industrial Primers 376Sherwin Williams Hi-Solids Alkyd Metal Primer B50NZ2 • 308Sigma Coatings Sigmarine Multiprimer 7117 390Sigma Coatings Sigmarine Primer ZP 7135 372Tnemec Company Azeron Primer FD88 • 330Tnemec Company Versare Primer 4 342
PRIMERAlkyd - Inhibited
2.0 - 3.0 mils DFT
Ameron Amercoat 5405 • 327Carboline Carbocoat 139 • 240Devoe Devguard 4308 428Devoe Devguard 4348 • 340Hempel Coatings (USA), Inc. Hempalin Enamel 5214 410International Interlac 665 427PPG Industries 7-282 • 336Sherwin Williams Industrial Enamel B54Z Series 417Sherwin Williams Industrial Enamel VOC B54-Z Series • 309Sigma Coatings Sigmarine BTD 7238 345Tnemec Company Enduratone 23 341Tnemec Company Hi-Build Tneme-Gloss 2H 351
TIECOATAlkyd Enamel
2.0 - 3.0 mils DFT
Ameron Amercoat 5405 • 327Carboline Carbocoat 139 • 240Devoe Devguard 4308 428Devoe Devguard 4348 • 340Hempel Coatings (USA), Inc. Hempalin Enamel 5214 410International Interlac 665 427Jotun Paints Pilot II 418PPG Industries 7-282 • 336Sherwin Williams Industrial Enamel B54Z Series 417Sherwin Williams Industrial Enamel VOC B54-Z Series • 309Sigma Coatings Sigmarine BTD 7238 345Tnemec Company Enduratone 23 341Tnemec Company Hi-Build Tneme-Gloss 2H 351
TOPCOATAlkyd Enamel
2.0 - 3.0 mils DFT
QRG - 13
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 12/31/2003
SYSTEM DATA SHEET Coatings ManualChevron Corporation
2.3Silicone Alkyd | Silicone Acrylic
1.0 mils (max)
SSPC-SP10 (NACE No. 2) Near-white blast finish.
3.0 mils (min)
Use this system.
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 6/24/2004
SYSTEM DATA SHEET Coatings ManualChevron Corporation
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
Two-Component Systems
Keep inorganic zinc silicate mixed, using agitated pot while applying.
Some of these coatings require a heated curing before handling.
Ameron Dimetcote 9 491Ameron Dimetcote 9HS • 323Carboline Carbozinc 11 515Carboline Carbozinc 11 HS • 264Dampney Company, Inc. Thurmalox 245C Silicone Zinc Dust Primer 413Devoe Catha-Coat 304V • 336Hempel Coatings (USA), Inc. Galvosil 1578 520International Interzinc 22 490International Interzinc 22HS • 340Jotun Paints Resist GTI 458PPG Industries Metalhide 1001 Primer 97-673/97-674 397Sherwin Williams Zinc Clad II B69V3/B69D11 462Sherwin Williams Zinc Clad II HS B69VZ1/B69VZ3/B69D11 • 312Sigma Coatings Silguard MC II 7551 US • 324Tnemec Company SpanPrime IOZ 356 397Tnemec Company Tneme-Zinc 90-96 • 323
PRIMERSelf-Cured Inorganic
Zinc - Solvent Reducible
2.0 - 3.0 mils DFT
Non-catalyzed silicones remain tacky until exposed to heat above 300°F to 400°F. * Thumalox 230C topcoat will go over ONLY Thurmaloc 245C Silicone Zinc Dust Primer.
Ameron PSX 892HS • 324Carboline Thermaline 4700 480Dampney Company, Inc. Thurmalox 230C* 360Devoe HT-12 572Hempel Coatings (USA), Inc. 5690 400Hempel Coatings (USA), Inc. 5691 586International Intertherm 50 495Jotun Paints Solvalitt 497PPG Industries 97-724 554Sherwin Williams Hi-Temp Aluminum 100-A-518 420Sigma Coatings Sigmatherm Aluminum 5267 600Tnemec Company Silicone Aluminum 39-1061 587
TOPCOATSilicone - High Temp
1.5 - 2.5 mils DFT
QRG - 15
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 6/24/2004
SYSTEM DATA SHEET Coatings ManualChevron Corporation
2.5Self-Cured Inorganic Zinc | Silicone Acrylic
1.5 - 2.5 mils
SSPC-SP6 (NACE No. 3) Commercial blast finish.
4.5 mils (min)
Coating System 2.3
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
Two-Component Systems
Keep inorganic zinc silicate mixed, using agitated pot while applying.
Ameron Dimetcote 9 491Ameron Dimetcote 9HS • 323Carboline Carbozinc 11 515Carboline Carbozinc 11 HS • 264Devoe Catha-Coat 304V • 336Hempel Coatings (USA), Inc. Galvosil 15680 • 320Hempel Coatings (USA), Inc. Galvosil 1578 520International Interzinc 22 490International Interzinc 22HS • 340Jotun Paints Resist GTI 458PPG Industries Metalhide 1001 Primer 97-673/97-674 397Sherwin Williams Zinc Clad II B69V3/B69D11 462Sherwin Williams Zinc Clad II HS B69VZ1/B69VZ3/B69D11 • 312
PRIMERSelf-Cured Inorganic
Zinc - Solvent Reducible
2.0 - 3.0 mils DFT
Some of these coatings require a heated curing before handling.
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 6/24/2004
SYSTEM DATA SHEET Coatings ManualChevron Corporation
Coating System 2.13. DO NOT touch up with primer from Coating System 2.6 after applying topcoat.
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
Two-Component Systems
Keep inorganic zinc silicate mixed, using agitated pot while applying.
Ameron Dimetcote 9 491Ameron Dimetcote 9HS • 323Carboline Carbozinc 11 515Carboline Carbozinc 11 HS • 264Devoe Catha-Coat 304V • 336Hempel Coatings (USA), Inc. Galvosil 15680 • 320Hempel Coatings (USA), Inc. Galvosil 1578 520International Interzinc 22 490International Interzinc 22HS • 340Jotun Paints Resist 78 465PPG Industries Metalhide 1001 Primer 97-673/97-674 397Sherwin Williams Zinc Clad II B69V3/B69D11 462Sherwin Williams Zinc Clad II HS B69VZ1/B69VZ3/B69D11 • 312Sigma Coatings Silguard MC II 7551 US • 324Tnemec Company SpanPrime IOZ 356 397Tnemec Company Tneme-Zinc 90-96 • 323
PRIMERSelf-Cured Inorganic
Zinc - Solvent Reducible
2.0 - 3.0 mils DFT
Follow the manufacturer's instructions.
Ameron Amercoat 385 • 276Carboline Carboguard 890 • 214Devoe Devran 224HS • 212Hempel Coatings (USA), Inc. Hempadur 4520 400Hempel Coatings (USA), Inc. Hempadur 45880 • 215International Interseal 670 HS • 240Jotun Paints Penguard HB 380PPG Industries Aquapon 97-130 373Sherwin Williams Macropoxy 646 B58-600 Series/B68V600 • 235Sigma Coatings CM II 7456 US • 300Tnemec Company Hi-Build Epoxoline II N69 • 253Tnemec Company S.T. Typoxy N27 • 300
TOPCOATEpoxy - Polyamide
High Build
5.0 - 7.0 mils DFT
QRG - 17
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 6/24/2004
SYSTEM DATA SHEET Coatings ManualChevron Corporation
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
Two-Component Systems
Some of these coatings require a heated curing before handling.
Ameron PSX 892HS • 324Carboline Thermaline 4700 480Dampney Company, Inc. Thurmalox 245C Silicone Zinc Dust Primer 413Devoe HT-12 572Hempel Coatings (USA), Inc. 5690 400Hempel Coatings (USA), Inc. 5691 586International Intertherm 50 495Jotun Paints Solvalitt 497PPG Industries 97-724 554Sherwin Williams Hi-Temp Aluminum 100-A-518 420Tnemec Company Silicone Aluminum 39-1061 587
PRIMERSilicone - High Temp
1.5 - 2.5 mils DFT
Non-catalyzed silicones remain tacky until exposed to heat above 300°F to 400°F. * Thumalox 230C topcoat will go over ONLY Thurmaloc 245C Silicone Zinc Dust Primer.
Ameron PSX 892HS • 324Carboline Thermaline 4700 480Dampney Company, Inc. Thurmalox 230C* 360Devoe HT-12 572Hempel Coatings (USA), Inc. 5690 400Hempel Coatings (USA), Inc. 5691 586International Intertherm 50 495Jotun Paints Solvalitt 497PPG Industries 97-724 554Sherwin Williams Hi-Temp Aluminum 100-A-518 420Tnemec Company Silicone Aluminum 39-1061 587
TOPCOATSilicone - High Temp
1.5 - 2.5 mils DFT
QRG - 18
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 3/21/2003
SYSTEM DATA SHEET Coatings ManualChevron Corporation
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
Two-Component Systems
PRIMER
1.0 mil (min) DFT
Some of these coatings require a heated curing before handling.
Ameron Amercoat 5405 • 327Carboline Carbocoat 139 • 240Devoe Devguard 4308 428Devoe Devguard 4348 • 340Hempel Coatings (USA), Inc. Hempalin Enamel 5214 410International Interlac 665 427Jotun Paints Pilot II 418PPG Industries 7-282 • 336Sherwin Williams Industrial Enamel B54Z Series 417Sherwin Williams Industrial Enamel VOC B54-Z Series • 309Sigma Coatings Sigmarine BTD 7238 345Tnemec Company Enduratone 23 341Tnemec Company Hi-Build Tneme-Gloss 2H 351
TOPCOATAlkyd Enamel
2.0 - 3.0 mils DFT
QRG - 19
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 3/21/2003
SYSTEM DATA SHEET Coatings ManualChevron Corporation
2.9Manufacturer's Standard | Alkyd Enamel | Alkyd Enamel
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
Two-Component Systems
PRIMER
1.0 mil (min) DFTAmeron Amercoat 5405 • 327Carboline Carbocoat 139 • 240Devoe Devguard 4308 428Devoe Devguard 4348 • 340Hempel Coatings (USA), Inc. Hempalin Enamel 5214 410International Interlac 665 427PPG Industries 7-282 • 336Sherwin Williams Industrial Enamel B54Z Series 417Sherwin Williams Industrial Enamel VOC B54-Z Series • 309Sigma Coatings Sigmarine BTD 7238 345Tnemec Company Enduratone 23 341Tnemec Company Hi-Build Tneme-Gloss 2H 351
TIECOATAlkyd Enamel
2.0 - 3.0 mils DFT
Ameron Amercoat 5405 • 327Carboline Carbocoat 139 • 240Devoe Devguard 4308 428Devoe Devguard 4348 • 340Hempel Coatings (USA), Inc. Hempalin Enamel 5214 410International Interlac 665 427Jotun Paints Pilot II 418PPG Industries 7-282 • 336Sherwin Williams Industrial Enamel B54Z Series 417Sherwin Williams Industrial Enamel VOC B54-Z Series • 309Sigma Coatings Sigmarine BTD 7238 345Tnemec Company Enduratone 23 341Tnemec Company Hi-Build Tneme-Gloss 2H 351
TOPCOATAlkyd Enamel
2.0 - 3.0 mils DFT
QRG - 20
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 1/8/2004
SYSTEM DATA SHEET Coatings ManualChevron Corporation
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 1/8/2004
SYSTEM DATA SHEET Coatings ManualChevron Corporation
2.11Manufacturer's Standard | High-Temperature Silicone
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
Two-Component Systems
PRIMER
1.0 mil (min) DFT
Non-catalyzed silicones remain tacky until exposed to heat above 300°F to 400°F. * Thumalox 230C topcoat will go over ONLY Thurmaloc 245C Silicone Zinc Dust Primer.
Ameron PSX 892HS • 324Carboline Thermaline 4700 480Dampney Company, Inc. Thurmalox 230C* 360Devoe HT-12 572Hempel Coatings (USA), Inc. 5690 400Hempel Coatings (USA), Inc. 5691 586International Intertherm 50 495Jotun Paints Solvalitt 497PPG Industries 97-724 554Sherwin Williams Hi-Temp Aluminum 100-A-518 420Sherwin Williams Poly-Glass Laminate 939 Series/531-0-006 • 40Tnemec Company Silicone Aluminum 39-1061 587
TOPCOATSilicone - High Temp
1.5 - 2.5 mils DFT
QRG - 22
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 5/9/2002
SYSTEM DATA SHEET Coatings ManualChevron Corporation
2.12Epoxy Mastic - Surface-Tolerant Primer | Polyamide Epoxy (Finish)
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
Two-Component Systems
Available in colors. May use System 2.12.1 Aluminum-Filled Epoxy Mastic (Surface-Tolerant Primer) for better performance if aluminum color is acceptable.
Ameron Amerlock 400 • 120Carboline Carboguard 890 • 214Devoe Devran 224HS • 212Hempel Coatings (USA), Inc. Hempadur 4520 400Hempel Coatings (USA), Inc. Hempadur 45880 • 215International Interseal 670 HS • 240Jotun Paints Penguard Topcoat 400PPG Industries Aquapon 97-130 373Sherwin Williams Sher-Tile B-67-200 Series/B67V200 • 175Sherwin Williams Tile-Clad II Plus B62-500 Series/B62V500 • 275Sigma Coatings CM II 7456 US • 300Tnemec Company Hi-Build Epoxoline 66 362Tnemec Company Hi-Build Epoxoline II N69 • 253
TOPCOATEpoxy - Polyamide
3.0 - 4.0 mils DFT
QRG - 23
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 6/30/2004
SYSTEM DATA SHEET Coatings ManualChevron Corporation
2.12.1Epoxy Mastic - Surface-Tolerant Primer - Aluminum Color Only | Polyamide Epoxy (Finish)
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
Two-Component Systems
System 2.12 is available in colors.
Ameron Amerlock 400 AL • 120Carboline Carbomastic 15 • 88Devoe Bar-Rust 239 • 119Hempel Coatings (USA), Inc. Hempadur 45880-19870 • 215International Interseal 670 HS • 240Jotun Paints Jotamastic 87 AL • 110PPG Industries UC65372/UC65373 • 118Sherwin Williams Epoxy Mastic Aluminum II B62S100/BV100 • 171Sigma Coatings TCP Aluminum 7477 • 240Tnemec Company Chembuild 135-1243 • 133Tnemec Company S.T. Typoxy N27 • 300
PRIMEREpoxy Mastic -
Surface Tolerant - Aluminum Filled
5.0 - 7.0 mils DFT
Ameron Amerlock 400 • 120Carboline Carboguard 890 • 214Devoe Devran 224HS • 212Hempel Coatings (USA), Inc. Hempadur 4520 400Hempel Coatings (USA), Inc. Hempadur 45880 • 215International Interseal 670 HS • 240Jotun Paints Penguard Topcoat 400PPG Industries Aquapon 97-130 373Sherwin Williams Sher-Tile B-67-200 Series/B67V200 • 175Sherwin Williams Tile-Clad II Plus B62-500 Series/B62V500 • 275Sigma Coatings CM II 7456 US • 300Tnemec Company Hi-Build Epoxoline 66 362Tnemec Company Hi-Build Epoxoline II N69 • 253
TOPCOATEpoxy - Polyamide
3.0 - 4.0 mils DFT
QRG - 24
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 6/30/2004
SYSTEM DATA SHEET Coatings ManualChevron Corporation
2.13Epoxy Mastic - Surface-Tolerant Primer | Polyamide Epoxy (High Build)
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
Two-Component Systems
Available in colors. May use System 2.13.1 Aluminum-Filled Epoxy Mastic (Surface-Tolerant Primer) for better performance if aluminum color is acceptable.
Follow the manufacturer's instructions. Recognize that lower temperatures will require a longer cure.
Ameron Amerlock 400 • 120Carboline Carboguard 890 • 214Devoe Devran 224HS • 212Hempel Coatings (USA), Inc. Hempadur 4520 400Hempel Coatings (USA), Inc. Hempadur 45880 • 215International Interseal 670 HS • 240Jotun Paints Penguard Topcoat 400PPG Industries Aquapon 97-130 373Sherwin Williams Sher-Tile B-67-200 Series/B67V200 • 175Sigma Coatings CM II 7456 US • 300Tnemec Company S.T. Typoxy N27 • 300
TOPCOATEpoxy - Polyamide
High Build
5.0 - 7.0 mils DFT
QRG - 25
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 6/30/2004
SYSTEM DATA SHEET Coatings ManualChevron Corporation
2.13.1Epoxy Mastic - Surface-Tolerant Primer - Aluminum Color Only | Polyamide Epoxy (High Build)
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
Two-Component Systems
System 2.13 is available in colors.
Ameron Amerlock 400 AL • 120Carboline Carbomastic 15 • 88Devoe Bar-Rust 239 • 119Hempel Coatings (USA), Inc. Hempadur 45880-19870 • 215International Interseal 670 HS • 240Jotun Paints Jotamastic 87 AL • 110PPG Industries UC65372/UC65373 • 118Sherwin Williams Epoxy Mastic Aluminum II B62S100/BV100 • 171Sigma Coatings TCP Aluminum 7477 • 240Tnemec Company Chembuild 135-1243 • 133
PRIMEREpoxy Mastic -
Surface Tolerant - Aluminum Filled
5.0 - 7.0 mils DFT
Follow the manufacturer's instructions. Recognize that lower temperatures will require a longer cure.
Ameron Amerlock 400 • 120Carboline Carboguard 890 • 214Devoe Devran 224HS • 212Hempel Coatings (USA), Inc. Hempadur 4520 400Hempel Coatings (USA), Inc. Hempadur 45880 • 215International Interseal 670 HS • 240Jotun Paints Primastic • 238PPG Industries Aquapon 97-130 373Sherwin Williams Sher-Tile B-67-200 Series/B67V200 • 175Sigma Coatings CM II 7456 US • 300Tnemec Company S.T. Typoxy N27 • 300
TOPCOATEpoxy - Polyamide
High Build
5.0 - 7.0 mils DFT
QRG - 26
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 6/30/2004
SYSTEM DATA SHEET Coatings ManualChevron Corporation
2.14Polyamide Epoxy | Polyamide Epoxy
1.5 - 2.5 mils
SSPC-SP6 (NACE No. 3) Commercial blast finish.
6.0 mils (min) (if applying both coats)
Use this system.
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
Two-Component Systems
Ameron Amercoat 385 • 276Carboline Carboguard 893 • 195Devoe Devran 224HS • 212Hempel Coatings (USA), Inc. Hempadur 4520 400Hempel Coatings (USA), Inc. Hempadur 45880 • 215International Intergard270 • 95International Interseal 670 HS • 240Jotun Paints Jotamastic 87 • 196PPG Industries 97-145 • 128Sherwin Williams Recoatable Epoxy Primer B67R5/B67V5 • 295Sigma Coatings Sigmacover Primer II 7413US • 300Sigma Coatings Sigmarite PC Unicoat 5483 PC • 252Tnemec Company Hi-Build Epoxoline 66 362Tnemec Company Hi-Build Epoxoline II N69 • 253
PRIMEREpoxy - Polyamide
3.0 - 4.0 mils DFT
Topcoat is required only where moisture will tend to collect under wet insulation (such as at insulation support rings).
Ameron Amercoat 385 • 276Carboline Carboguard 890 • 214Devoe Devran 224HS • 212Hempel Coatings (USA), Inc. Hempadur 4520 400Hempel Coatings (USA), Inc. Hempadur 45880 • 215International Intergard 401 • 64International Interseal 670 HS • 240Jotun Paints Penguard Topcoat 400PPG Industries 97-145 • 128Sherwin Williams Recoatable Epoxy Primer B67R5/B67V5 • 295Sigma Coatings CM II 7456 US • 300Tnemec Company Hi-Build Epoxoline 66 362Tnemec Company Hi-Build Epoxoline II N69 • 253
TOPCOATEpoxy - Polyamide
3.0 - 4.0 mils DFT
QRG - 27
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 6/29/2004
SYSTEM DATA SHEET Coatings ManualChevron Corporation
2.15Epoxy Mastic - Surface-Tolerant Primer | Aliphatic Polyurethane
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
Two-Component Systems
Available in colors. May use System 2.15.1 Aluminum-Filled Epoxy Mastic (Surface-Tolerant Primer) for better performance if aluminum color is acceptable.
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 1/8/2004
SYSTEM DATA SHEET Coatings ManualChevron Corporation
2.15.1Epoxy Mastic - Surface-Tolerant Primer - Aluminum Color Only | Aliphatic Polyurethane
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 12/31/2003
SYSTEM DATA SHEET Coatings ManualChevron Corporation
Coating System (CS) 3.5. After applying the tie-coat: (Repair any damage exposing bare metal with CS 3.5. Repair any damage to the inorganic zinc primer, as necessary, with CS 3.5 to maintain specified film thickness.) DO NOT APPLY the inorganic zinc primer on top of or overlapping the final two coats of CS 3.1.1.
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
Three-Component Systems
Keep inorganic zinc silicate mixed, using agitated pot while applying.
Ameron Dimetcote 9 491Ameron Dimetcote 9HS • 323Carboline Carbozinc 11 515Carboline Carbozinc 11 HS • 264Devoe Catha-Coat 304V • 336Hempel Coatings (USA), Inc. Galvosil 1568 • 320Hempel Coatings (USA), Inc. Galvosil 1578 520International Interzinc 22 490International Interzinc 22HS • 340Jotun Paints Resist 78 465PPG Industries Metalhide 1001 Primer 97-673/97-674 397Sherwin Williams Zinc Clad II B69V3/B69D11 462Sherwin Williams Zinc Clad II HS B69VZ1/B69VZ3/B69D11 • 312Sigma Coatings Silguard MC II 7551 US • 324Tnemec Company SpanPrime IOZ 356 397Tnemec Company Tneme-Zinc 90-96 • 323
PRIMERSelf-Cured Inorganic
Zinc - Solvent Reducible
2.0 - 3.0 mils DFT
Ameron Amercoat 385 • 276Carboline Carboguard 893 • 195Devoe Devran 224HS • 212Hempel Coatings (USA), Inc. Hempadur 4520 400Hempel Coatings (USA), Inc. Hempadur 45880 • 215International Intergard 475 HS • 175Jotun Paints Penguard Tiecoat 100 480PPG Industries 97-148 • 0Sherwin Williams Macropoxy 646 B58-600 Series/B68V600 • 235Sigma Coatings Sigmarite PC Unicoat 5483 PC • 252Tnemec Company Chembuild 135 • 133Tnemec Company S.T. Typoxy N27 • 300
TIECOATEpoxy - Polyamide
High Build
5.0 - 7.0 mils DFT
QRG - 30
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 6/24/2004
SYSTEM DATA SHEET Coatings ManualChevron Corporation
Respirators are strongly recommended when applying polyurethane.
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 6/24/2004
SYSTEM DATA SHEET Coatings ManualChevron Corporation
Coating System (CS) 3.5. After applying the tie-coat: (Repair any damage exposing bare metal with CS 3.5. Repair any damage to the inorganic zinc primer, as necessary, with CS 3.5 to maintain specified film thickness.) DO NOT APPLY the inorganic zinc primer on top of or overlapping the final two coats of CS 3.1.1.
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
Three-Component Systems
Keep inorganic zinc silicate mixed, using agitated pot while applying. See also System 3.3 (solvent reducible).
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 6/24/2004
SYSTEM DATA SHEET Coatings ManualChevron Corporation
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 1/8/2004
SYSTEM DATA SHEET Coatings ManualChevron Corporation
Coating System 3.4. After applying the tie-coat over the inorganic zinc primer, repair any damage that exposes the base metal with Coating System 3.4. DO NOT APPLY inorganic zinc on top of (or overlapping) the final three coats of System 3.3.
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
Three-Component Systems
Keep inorganic zinc silicate mixed, using agitated pot while applying. Use System 3.3.1 if you need a water-reducible primer.
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 6/30/2004
SYSTEM DATA SHEET Coatings ManualChevron Corporation
Coating System 3.4. After applying the tie-coat over the inorganic zinc primer, repair any damage that exposes the base metal with Coating System 3.4. DO NOT APPLY inorganic zinc on top of (or overlapping) the final three coats of System 3.3.1.
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
Three-Component Systems
Keep inorganic zinc silicate mixed, using agitated pot while applying. See also System 3.3 (solvent reducible).
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 6/30/2004
SYSTEM DATA SHEET Coatings ManualChevron Corporation
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 6/30/2004
SYSTEM DATA SHEET Coatings ManualChevron Corporation
SSPC-SP3 Power-brush finish. (Remove all loose paint and rust.)
12.0 mils (min)
Use this system.
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
Three-Component Systems
Available in colors. May use System 3.5.1 Aluminum-Filled Epoxy Mastic (Surface-Tolerant Primer) for better performance if aluminum color is acceptable.
Vendors of mechanical equipment normally have their own standard coatings and find it economically impractical to change to purchaser-specified systems such as this one. Chevron's specified system must be applied unless the vendor obtains written approval from Chevron to substitute another. The alternative is to accept the vendor's standard primer and then apply Coating System 3.7 (Manufacturer's Standard/Universal Primer/Polyamide Epoxy (High Build)/Aliphatic Polyurethane).
QRG - 37
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 1/8/2004
SYSTEM DATA SHEET Coatings ManualChevron Corporation
3.5.1Epoxy Mastic - Aluminum Color Only | Polyamide Epoxy (High Build) | Aliphatic Polyurethane
Vendors of mechanical equipment normally have their own standard coatings and find it economically impractical to change to purchaser-specified systems such as this one. Chevron's specified system must be applied unless the vendor obtains written approval from Chevron to substitute another. The alternative is to accept the vendor's standard primer and then apply Coating System 3.7 (Manufacturer's Standard/Universal Primer/Polyamide Epoxy (High Build)/Aliphatic Polyurethane).
QRG - 38
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 1/8/2004
SYSTEM DATA SHEET Coatings ManualChevron Corporation
3.7Manufacturer's Standard | Universal Primer | Polyamide Epoxy (High Build) | Aliphatic Polyurethane
1.5 - 3.0 mils
SSPC-SP6 (NACE No. 4) Commercial blast finish.
11.0 mils (min)
Use this system without reapplying manufacturer's standard primer.
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
Three-Component Systems
Apply universal primer over manufacturer's standard primer; then apply tiecoat and topcoat.
PRIMER [Mfg's Standard]
2.0 - 3.0 mils DFT
Ameron Amercoat 180 • 312Carboline Carbocoat 150HG • 336Carboline Rustbond Penetrating Sealer • 24Devoe Devguard 4160 419Hempel Coatings (USA), Inc. Uni-Primer 1314 520International Interseal 670 HS • 240Jotun Paints Penguard HB 380PPG Industries 97-680 414Sherwin Williams Hi-Solids Alkyd Metal Primer B50NZ3 • 308Sherwin Williams Kem Kromik B50NZ6 415Sigma Coatings Sigmacover Primer II 7413US • 300Tnemec Company Chem-Prime HS 37H 348
PRIMERUniversal Primer
2.0 - 3.0 mils DFT
Ameron Amercoat 385 • 276Carboline Carboguard 890 • 214Devoe Devran 224HS • 212Hempel Coatings (USA), Inc. Hempadur 4520 400Hempel Coatings (USA), Inc. Hempadur 45880 • 215International Interseal 670 HS • 240Jotun Paints Penguard HB 380PPG Industries Aquapon 97-130 373Sherwin Williams Macropoxy 646 B58-600 Series/B68V600 • 235Sigma Coatings CM II 7456 US • 300Tnemec Company S.T. Typoxy N27 • 300
TIECOATEpoxy - Polyamide
High Build
5.0 - 7.0 mils DFT
Respirators are strongly recommended when applying polyurethane.
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 1/8/2004
SYSTEM DATA SHEET Coatings ManualChevron Corporation
3.8Manufacturer's Standard | Universal Primer | Aliphatic Polyurethane
Use this system without reapplying manufacturer's standard primer.
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
Three-Component Systems
Apply universal primer over manufacturer's standard primer; then apply tiecoat and topcoat.
PRIMER [Mfg's Standard]
2.0 - 3.0 mils (min) DFT
Ameron Amercoat 180 • 312Carboline Carbocoat 150HG • 336Carboline Rustbond Penetrating Sealer • 24Devoe Devguard 4160 419Hempel Coatings (USA), Inc. Uni-Primer 1314 520International Interseal 670 HS • 240Jotun Paints Penguard HB 380PPG Industries 97-680 414Sherwin Williams Hi-Solids Alkyd Metal Primer B50NZ3 • 308Sherwin Williams Kem Kromik B50NZ6 415Sigma Coatings Sigmacover Primer II 7413US • 300Tnemec Company Chem-Prime HS 37H 348
PRIMERUniversal Primer
2.0 - 3.0 mils DFT
Respirators are strongly recommended when applying polyurethane.
Ameron Amercoat 450 Series • 335Carboline Carbothane 134 HG • 288Devoe Devthane 379 • 311Hempel Coatings (USA), Inc. 55 Series 372Hempel Coatings (USA), Inc. Hempathane 5595 • 332International Interthane 990 395International Interthane 990HS • 332Jotun Paints Hardtop HB • 256PPG Industries 95-812 • 241Sherwin Williams Hi-Solids Polyurethane B65-300 SeriesB65/ • 289Sigma Coatings Sigmadur Versafinish 5522 • 320Tnemec Company Endura-Shield 74 • 229Tnemec Company Endura-Shield 75 • 193
TOPCOATPolyurethane -
Aliphatic
2.0 - 3.0 mils DFT
QRG - 40
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 1/8/2004
SYSTEM DATA SHEET Coatings ManualChevron Corporation
4.1Splash Zone Coating - Sprayable
3.0 - 4.0 mils
SSPC-SP10 (NACE No. 2) Near-white finish.
Per manufacturer's recommendation.
Use this system for repairs before putting components in immersion service. After putting in service, use this system above the waterline and System 4.1.1 below the waterline.
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 1/8/2004
SYSTEM DATA SHEET Coatings ManualChevron Corporation
4.1.1Splash Zone Compound - Asbestos Free Rated to Cure Underwater
3.0 - 4.0 mils
SSPC-SP10 (NACE No. 2) Near-white finish.
125.0 mils (min)
After putting in service, use this system below the waterline and System 4.1 above the waterline.
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 2/16/2004
SYSTEM DATA SHEET Coatings ManualChevron Corporation
4.2Monel Sheath for Splash Zones
Not applicable
Grind steel surfaces to remove rust completely in areas where Monel is to be welded.
16 gage (0.062 inch)*
N/A
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
Specialty Coating Systems
Clad the specified portion of the splash zone with cold rolled, plain, unpolished, Monel sheathing per ASTM B-127. Weld the Monel sheathing continuously on all edges. Overlap all joints in the Monel sheathing by four inches. Require contractor to submit to Chevron for approval the shop drawings showing application details for Monel. Ensure full corrosion protection to the portion of the structure covered by Monel by requiring water-tight welds fasten Monel sheathing to steel members and Monel to Monel. Inspect all such welds with liquid-penetrant testing. Repair all defects exceeding those allowed in AWS D1.1 par. 9.25. Weld Monel to steel and Monel to Monel with only GMAW or GTAW processes using Monel filler metal conforming to AWS 5.14 class ERNi Cu-7. Qualify all weld procedures and welders working with Monel according to AWS D1.1 as for a fillet weld using a macroetch cross-section test. Recognize that Monel can tear if posed to mechanical damage. Heavier gage of Monel can provide some additional tear resistance, but not a substantial difference. Consider cost and handling before selecting heavier-gage Monel. *This is not DFT, this is Minimum Thickness.
QRG - 43
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 5/15/1998
SYSTEM DATA SHEET Coatings ManualChevron Corporation
4.3Vulcanized Neoprene for Splash Zones
3.0 - 4.0 mils (max)
SSPC-SP10 (NACE No. 2) Near-white blast finish.
0.5- 1.0 inch*
N/A
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
Specialty Coating Systems
Ship sections to be coated to contractor's facility for application of vulcanized neoprene, unless otherwise approved in writing by Chevron.
Mark Tool Splashtron • 0Vulcanized Neoprene
0.5 - 1.0 inch thick
*This is not DFT, this is Minimum Thickness.
QRG - 44
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 5/27/1998
SYSTEM DATA SHEET Coatings ManualChevron Corporation
FIREPROOFING INTACT: Weathercoat and topcoat for touch-up. FIREPROOFING DAMAGED: Repair fireproofing; finish with weathercoat and topcoat. PRIMER DAMAGED: Touch up with polyamide epoxy primer; then apply remainder of system.
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
Specialty Coating Systems
Where moisture will tend to collect under wet insulation (such as at insulation support rings) select Coating System 2.14.
Ameron Amercoat 385 • 276AOC Penguard Primer • 238Carboline Carboguard 893 • 195Devoe Devran 224HS • 212Hempel Coatings (USA), Inc. Hempadur 45880 • 215International Intercure 200 • 320International Intergard 251 390PPG Industries 97-145 • 128Sherwin Williams Recoatable Epoxy Primer B67R5/B67V5 • 295Sigma Coatings Sigmarite PC Unicoat 5483 PC • 252Tnemec Company S.T. Typoxy N27 • 300
PRIMEREpoxy - Polyamide
3.0 - 4.0 mils DFT
Chevron specifies fireproofing type and thickness. See Chevron's Fire Protection Manual. Certain manufacturers require a tiecoat between the fireproofing and weathercoating. Before sandblasting, weld 12-gage steel studs to the steel to support the mesh reinforcement. Alternative reinforcing techniques may be acceptable; but they require prior written authorization from Chevron. Allow fireproofing to cure ten days at 70°F before applying weathercoat; lower temps require a longer cure. Apply weathercoat in two coats with the first thinned to penetrate, unless the manufacturer recommends a tiecoat instead.
FIREPROOFING
Ameron Amercoat 385 • 276Carboline Carboguard 890 • 214Devoe Devran 224HS • 212Hempel Coatings (USA), Inc. Hempadur 45880 • 215Hempel Coatings (USA), Inc. Hempadur 5540 • 285International Intergard 475 HS • 175Jotun Paints Penguard HB 380PPG Industries Aquapon 97-130 373Sherwin Williams Macropoxy 646 B58-600 Series/B68V600 • 235Sigma Coatings CM II 7456 US • 300Tnemec Company S.T. Typoxy N27 • 300
TIECOATEpoxy - Polyamide
High Build
5.0 - 7.0 mils DFT
Respirators are strongly recommended when applying polyurethane.
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 6/29/2004
SYSTEM DATA SHEET Coatings ManualChevron Corporation
SSPC-SP6 (NACE No. 3) Commercial blast finish; or SPPC-SP10 (NACE No. 2) Near-white finish (Depends on application. See appropriate COM-EF-68)
40.0 mils (min)
Use this system.
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
Specialty Coating Systems
Must add sand.
Ceilcote Flakeline 211 or 212 • 0Dudick Protecto-Coat 500 • 250Glidden Glidflake 7500 • 250Hempel Coatings (USA), Inc. Polyester GF 35920 • 35International Interzone 2000 • 35Jotun Paints Baltoflake • 75PPG Industries 90000/90002 420Sherwin Williams Coroplate I 948-W-016/531-0-006 • 240
PRIMERPolyester Non-Skid
30.0 - 40.0 mils DFT
Apply grit to these coatings to provide a non-skid surface. Apply polyester first at 30 mils. Sprinkle Chevron-approved 20 - 30 mesh garnet, alumina, or other grit evenly over the coating at a rate of 15 - 18 lbs per 100 sq ft. Spray apply a final 10.0 mils of isopolyester over the grit while the first coat is still sticky.
TIECOAT
20 - 30 Mesh Grit
Must add sand.
Ceilcote Flakeline 211 or 212 • 0Dudick Protecto-Coat 500 • 250Glidden Glidflake 7500 • 250Hempel Coatings (USA), Inc. Polyester GF 35920 • 35International Interzone 2000 • 35Jotun Paints Baltoflake with Carborex 20 • 75PPG Industries 94701, VOC • 337Sherwin Williams Coroplate I 948-W-016/531-0-006 • 240
TOPCOATPolyester Non-Skid
10.0 - 15.0 mils DFT
QRG - 46
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 1/8/2004
SYSTEM DATA SHEET Coatings ManualChevron Corporation
4.6Epoxy Non-Skid | Grit | Epoxy Non-Skid
3.0 - 4.0 mils
SSPC-SP6 (NACE No. 3) Commercial blast finish; or SPPC-SP10 (NACE No. 2) Near-white finish (Depends on application.)
20.0 - 25.0 mils (min)
Use this system.
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
Specialty Coating Systems
Use coating supplier's recommendation.
PRIMER
Non-skid grit is supplied in coatings. Specify size of grit when ordering.
TIECOAT
Method of application (spray, roller, brush) depends on the coating supplier selected.
Ameron Amerlock 400-GFK w/888 Additive • 172Carboline Carboguard 1209 with grit • 96Devoe Devgrip 237C • 340Hempel Coatings (USA), Inc. Hempadur 350International Interzone 954 • 130Jotun Paints Primastic with 3883 Non-Skid aggregate • 238PPG Industries 97-145 • 128PPG Industries Aquapon High Build with Grit 373Sherwin Williams ArmorSeal 300 • 340Sigma Coatings SigmaGlaze 5492 • 0Tnemec Company Tneme-Glaze 280 • 2
TOPCOATEpoxy Non-Skid
20.0 - 25.0 mils DFT
Respirators are strongly recommended when applying polyurethane. An aliphatic polyurethane coating may be applied over the epoxy non-skid for markings or prevention of chalking.
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 9/9/2004
SYSTEM DATA SHEET Coatings ManualChevron Corporation
8.1Nonreinforced Thin Film Coatings for Fresh-Water Immersion Service
2.0 - 3.0 mils
SSPC-SP5 (NACE No. 1) White metal surface.
10.0 mils (min) (see manufacturer's data sheets for min/max thickness per coat)
Use the same manufacturer's paint.
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
Non-Reinforced Thin Film Coatings for Immersion Service
These coatings are normally self-priming; but if a primer is required, use the chosen manufacturer's recommendation.
This list is limited to full-service national manufacturers. Local conditions may warrant adding local suppliers.* Designates single coat application, low temperature cure and application, and fast cure. Applied 20 -25 mils by Plural Component Equipment
QRG - 48
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 2/16/2004
SYSTEM DATA SHEET Coatings ManualChevron Corporation
8.2Nonreinforced Thin Film Coatings for Demineralized Water or Condensate Immersion Service
2.0 - 3.0 mils
SSPC-SP5 (NACE No. 1) White metal surface.
10.0 mils (min) (see manufacturer's data sheets for min/max thickness per coat)
Use the same manufacturer's paint.
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
Non-Reinforced Thin Film Coatings for Immersion Service
These coatings are normally self-priming; but if a primer is required, use the chosen manufacturer's recommendation.
If seam sealant or putty is required, use any of the following brands from the Acceptable Brands List: (Epoxy, Rivet and Seam Sealer (Spray or Trowel), Polysulfide Flexible Putty). This list is limited to full-service national manufacturers. Local conditions may warrant adding local suppliers. * Designates single coat application, low temperature cure and application, and fast cure. Applied 20 - 25 mils by Plural Component Equipment.
Sigma recommends that for temperatures above 140F, the Phenguard system is applied in three 4 mil coats (using Phenguard 7435 as the intermediate coat) rather than two 6mil coats.
QRG - 49
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 1/9/2004
SYSTEM DATA SHEET Coatings ManualChevron Corporation
8.3Nonreinforced Thin Film Coatings for FDA-Approved Potable Water Immersion Service
2.0 - 3.0 mils
SSPC-SP5 (NACE No. 1) White metal surface.
10.0 mils (min) (see manufacturer's data sheets for min/max thickness per coat)
Use the same manufacturer's paint.
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
Non-Reinforced Thin Film Coatings for Immersion Service
These coatings are normally self-priming; but if a primer is required, use the chosen manufacturer's recommendation.
PRIMER
Ameron Amercoat 395 FD 120°F• 217Carboline Carboguard 891 120°F• 214Hempel Coatings (USA), Inc. Hempadur 3573 120°F• 82International Interline 850 120°F• 225Sherwin Williams Tank Clad HS B62W80 120°F• 177Sigma Coatings Sigmaguard HSV 5476 120°F• 156Tnemec Company Pota-Pox Plus N140 120°F• 274Devoe Bar-Rust 233 H 180°F• 170Jotun Paints Tankguard Aqua 180°F• 10PPG Industries 95-132 180°F• 304
FIRST COATEpoxy
Nonreinforced Thin Film
5.0 - 6.0 mils DFT typically
Ameron Amercoat 395 FD 120°F• 217Carboline Carboguard 891 120°F• 214Hempel Coatings (USA), Inc. Hempadur 3573 120°F• 82International Interline 850 120°F• 225Sherwin Williams Tank Clad HS B62W80 120°F• 177Sigma Coatings Sigmaguard CSF 85 7785* 120°F• 5Sigma Coatings Sigmaguard HSV 5476 120°F• 156Tnemec Company Pota-Pox Plus N140 120°F• 274Devoe Bar-Rust 233 H 180°F• 170Jotun Paints Tankguard Aqua 180°F• 10PPG Industries 95-132 180°F• 304
SECOND COATEpoxy
Nonreinforced Thin Film
5.0 - 6.0 mils DFT typically
If seam sealant or putty is required, use the coating manufacturer's recommended FDA-approved material. This list is limited to full-service national manufacturers. Local conditions may warrant adding local suppliers.
QRG - 50
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 2/4/2004
SYSTEM DATA SHEET Coatings ManualChevron Corporation
8.4Nonreinforced Thin Film Coatings for Salt Water and Brine Immersion Service
2.0 - 3.0 mils
SSPC-SP5 (NACE No. 1) White metal surface.
10.0 mils (min) (see manufacturer's data sheets for min/max thickness per coat)
Use the same manufacturer's paint.
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
Non-Reinforced Thin Film Coatings for Immersion Service
These coatings are normally self-priming; but if a primer is required, use the chosen manufacturer's recommendation.
PRIMER
Sigma Coatings Sigmaguard EHB 7433 • 252Hempel Coatings (USA), Inc. Hempadur 1763 120°F• 255Jotun Paints Jotamastic 87 AL 120°F• 110Tnemec Company Hi-Build Epoxoline II N69 120°F• 253Tnemec Company Tneme-Liner 61 120°F• 169Ameron Amercoat 90HS 140°F• 323Carboline Carboguard 890 140°F• 214Carboline Phenoline 310* 140°F• 12International Interline 850 140°F• 225Devoe Bar-Rust 236 180°F• 170Sherwin Williams Phenicon HS 920-W-A11/700-C-685 180°F• 230Sigma Coatings Phenguard Primer 7409 212°F• 300
If seam sealant or putty is required, use any of the following brands from the Acceptable Brands List: (Epoxy, Rivet and Seam Sealer (Spray or Trowel), Polysulfide Flexible Putty). This list is limited to full-service national manufacturers. Local conditions may warrant adding local suppliers. * Designates single coat application, low temperature cure and application, and fast cure. Applied 20-25 mils by Plural Component Equipment.
Sigma recommends that for temperatures above 140F, the Phenguard system is applied in three 4 mil coats (using Phenguard 7435 as the intermediate coat) rather than two 6mil coats.
QRG - 51
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 1/9/2004
SYSTEM DATA SHEET Coatings ManualChevron Corporation
8.5Nonreinforced Thin Film Coatings for Produced-Water Immersion Service
2.0 - 3.0 mils
SSPC-SP5 (NACE No. 1) White metal surface.
10.0 mils (min) (see manufacturer's data sheets for min/max thickness per coat)
Use the same manufacturer's paint.
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
Non-Reinforced Thin Film Coatings for Immersion Service
These coatings are normally self-priming; but if a primer is required, use the chosen manufacturer's recommendation.
If seam sealant or putty is required, use any of the following brands from the Acceptable Brands List: (Epoxy, Rivet and Seam Sealer (Spray or Trowel), Polysulfide Flexible Putty). This list is limited to full-service national manufacturers. Local conditions may warrant adding local suppliers. * Designates single coat application, low temperature cure and application, and fast cure. Applied 20 - 25 mils by Plural Component Equipment.
Sigma recommends that for temperatures above 140F, the Phenguard system is applied in three 4 mil coats (using Phenguard 7435 as the intermediate coat) rather than two 6mil coats.
QRG - 52
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 6/24/2004
SYSTEM DATA SHEET Coatings ManualChevron Corporation
8.6Nonreinforced Thin Film Coatings for Crude Oil (Sweet or Sour) Immersion Service
2.0 - 3.0 mils
SSPC-SP5 (NACE No. 1) White metal surface.
10.0 mils (min) (see manufacturer's data sheets for min/max thickness per coat)
Use the same manufacturer's paint.
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
Non-Reinforced Thin Film Coatings for Immersion Service
These coatings are normally self-priming; but if a primer is required, use the chosen manufacturer's recommendation.
If seam sealant or putty is required, use any of the following brands from the Acceptable Brands List: (Epoxy, Rivet and Seam Sealer (Spray or Trowel), Polysulfide Flexible Putty). This list is limited to full-service national manufacturers. Local conditions may warrant adding local suppliers. * Designates single coat application, low temperature cure and application, and fast cure. Applied 20 - 25 mils by Plural Component Equipment.
Sigma recommends that for temperatures above 140F, the Phenguard system is applied in three 4 mil coats (using Phenguard 7435 as the intermediate coat) rather than two 6mil coats.
QRG - 53
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 1/9/2004
SYSTEM DATA SHEET Coatings ManualChevron Corporation
8.7Nonreinforced Thin Film Coatings for Fuel (Low-Aromatic) Immersion Service
2.0 - 3.0 mils
SSPC-SP5 (NACE No. 1) White metal surface.
10.0 mils (min) (see manufacturer's data sheets for min/max thickness per coat)
Use the same manufacturer's paint.
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
Non-Reinforced Thin Film Coatings for Immersion Service
These coatings are normally self-priming; but if a primer is required, use the chosen manufacturer's recommendation.
If seam sealant or putty is required, use any of the following brands from the Acceptable Brands List: (Epoxy, Rivet and Seam Sealer (Spray or Trowel), Polysulfide Flexible Putty). This list is limited to full-service national manufacturers. Local conditions may warrant adding local suppliers. * Designates single coat application, low temperature cure and application, and fast cure. Applied 20 - 25 mils by Plural Component Equipment.
Sigmaguard CSF 7443 is a single coat product at 16-20 mils.
QRG - 54
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 1/9/2004
SYSTEM DATA SHEET Coatings ManualChevron Corporation
8.8Nonreinforced Thin Film Coatings for Fuel (High-Aromatic) Immersion Service
2.0 - 3.0 mils
SSPC-SP5 (NACE No. 1) White metal surface.
10.0 mils (min) (see manufacturer's data sheets for min/max thickness per coat)
Use the same manufacturer's paint.
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
Non-Reinforced Thin Film Coatings for Immersion Service
These coatings are normally self-priming; but if a primer is required, use the chosen manufacturer's recommendation.
If seam sealant or putty is required, use any of the following brands from the Acceptable Brands List: (Epoxy, Rivet and Seam Sealer (Spray or Trowel), Polysulfide Flexible Putty). This list is limited to full-service national manufacturers. Local conditions may warrant adding local suppliers. * Designates single coat application, low temperature cure and application, fast cure. Applied 20 - 25 mils by Plural Component Equipment.
Sigmaguard CSF 7443 is a single coat product at 16-20 mils.
QRG - 55
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 1/9/2004
SYSTEM DATA SHEET Coatings ManualChevron Corporation
8.9Nonreinforced Thin Film Coatings for Aromatic-Hydrocarbon Immersion Service
2.0 - 3.0 mils
SSPC-SP5 (NACE No. 1) White metal surface.
10.0 mils (min) (see manufacturer's data sheets for min/max thickness per coat)
Use the same manufacturer's paint.
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
Non-Reinforced Thin Film Coatings for Immersion Service
These coatings are normally self-priming; but if a primer is required, use the chosen manufacturer's recommendation.
If seam sealant or putty is required, use any of the following brands from the Acceptable Brands List: (Epoxy, Rivet and Seam Sealer (Spray or Trowel), Polysulfide Flexible Putty). This list is limited to full-service national manufacturers. Local conditions may warrant adding local suppliers. * Designates single coat application, low temperature cure and application, and fast cure. Applied 20 - 25 mils by Plural Component Equipment.
Sigmaguard CSF 7443 is a single coat product at 16-20 mils.
QRG - 56
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 1/9/2004
SYSTEM DATA SHEET Coatings ManualChevron Corporation
8.10Nonreinforced Thin Film Coatings for Acetone Immersion Service
1.5 - 2.5 mils
SSPC-SP5 (NACE No. 1) White metal surface.
10.0 mils (min) (see manufacturer's data sheets for min/max thickness per coat)
Use the same manufacturer's paint.
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
Non-Reinforced Thin Film Coatings for Immersion Service
* These are special baked phenolic coatings: refer to manufacturer's data sheets.
Ameron Dimetcote 21-5 • 0Carboline Carbozinc 11 HS • 264Devoe Catha-Coat 305 • 0Hempel Coatings (USA), Inc. Galvosil 1562 • 0International Interzinc 22 490International Interzinc 22HS • 340Jotun Paints Resist GTI 458PPG Industries Metalhide 1001 Primer 97-673/97-674 397Sherwin Williams Zinc Clad II HS B69VZ1/B69VZ3/B69D11 • 312Sigma Coatings Silguard MC II 7551 US • 324Tnemec Company SpanPrime IOZ 356 397Tnemec Company Teneme-Zinc 90E-92 474
PRIMER
Nonreinforced Thin Film
2.5 - 3.5 mils DFT typically
DO NOT USE seam sealer or putty in this service. For alternatives consult one of CRTC's coating specialists. This list is limited to full-service national manufacturers. Local conditions may warrant adding local suppliers. * Designates single coat application, low temperature cure and application, and fast cure. Applied 20 - 25 mils by Plural Component Equipment.
QRG - 57
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 9/9/2004
SYSTEM DATA SHEET Coatings ManualChevron Corporation
8.11Nonreinforced Thin Film Coatings for Ethyl & Methyl Alcohol Immersion Service
2.0 - 3.0 mils
SSPC-SP5 (NACE No. 1) White metal surface.
10.0 mils (min) (see manufacturer's data sheets for min/max thickness per coat)
Use the same manufacturer's paint.
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
Non-Reinforced Thin Film Coatings for Immersion Service
These coatings are normally self-priming; but if a primer is required, use the chosen manufacturer's recommendation.
PRIMER
** Use 95-267 for ethanol service and 94301 in methanol.
DO NOT USE seam sealer or putty in this service. For alternatives consult one of CRTC's coating specialists. This list is limited to full-service national manufacturers. Local conditions may warrant adding local suppliers.
QRG - 58
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 2/16/2004
SYSTEM DATA SHEET Coatings ManualChevron Corporation
9.1Reinforced Thick Film Coatings for Fresh-Water Immersion Service
3.0 - 4.0 mils
SSPC-SP5 (NACE No. 1) White metal surface.
36.0 mils (min) (sprayable), 80.0 mils (min) (trowelable). (See manufacturers' data sheets for min/max thicknesses per coat)
Use the same manufacturer's paint.
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
Reinforced Thick Film Coatings for Immersion Service
These coatings are normally self-priming; but if a primer is required, use the chosen manufacturer's recommendation.
PRIMER
Roll each coat of spray- or trowelable glass flake to orient the flakes parallel to the substrate. Some systems require a 10-mil wax coat of glass flake-free resin. (See manufacturers' data sheets for wax coat requirements.)
Ameron Amercoat 351 + 880 Additive 140°F• 0Dudick Protecto-Coat 900HT 140°F• 0International Interzone 1000 140°F• 85Sherwin Williams Coroplate I 948-W-016/531-0-006 140°F• 240Jotun Paints Marathon IQ GF 150°F• 30Devoe Devmat 110 180°F• 39Industrial Environmental Coa EC 376 F 180°F• 36Carboline Phenoline 1205 200°F• 255PPG Industries 94301, VOC 210°F• 334
FIRST COAT
Reinforced Glass Flake
18.0 - 20.0 mils DFT (sprayable) 40.0 mils
DFT (trowelable)
Roll each coat of spray- or trowelable glass flake to orient the flakes parallel to the substrate. Some systems require a 10-mil wax coat of glass flake-free resin. (See manufacturers' data sheets for wax coat requirements.)
If seam sealant or putty is required, use any of the following brands from the Acceptable Brands List: (Polyester, Isophthalic, Polysulfide Flexible Putty). This list is limited to full-service national manufacturers. Local conditions may warrant adding local suppliers.
QRG - 59
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 2/16/2004
SYSTEM DATA SHEET Coatings ManualChevron Corporation
9.2Reinforced Thick Film Coatings for Demineralized Water or Condensate Immersion Service
3.0 - 4.0 mils
SSPC-SP5 (NACE No. 1) White metal surface.
36.0 mils (min) (sprayable), 80.0 mils (min) (trowelable). (See manufacturers' data sheets for min/max thicknesses per coat)
Use the same manufacturer's paint.
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
Reinforced Thick Film Coatings for Immersion Service
These coatings are normally self-priming; but if a primer is required, use the chosen manufacturer's recommendation.
PRIMER
Roll each coat of spray- or trowelable glass flake to orient the flakes parallel to the substrate. Some systems require a 10-mil wax coat of glass flake-free resin. (See manufacturers' data sheets for wax coat requirements.)
Roll each coat of spray- or trowelable glass flake to orient the flakes parallel to the substrate. Some systems require a 10-mil wax coat of glass flake-free resin. (See manufacturers' data sheets for wax coat requirements.)
If seam sealant or putty is required, use any of the following brands from the Acceptable Brands List: (Vinyl Ester, Rivet and Seam Sealer (Trowel), Polysulfide Flexible Putty). This list is limited to full-service national manufacturers. Local conditions may warrant adding local suppliers.
QRG - 60
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 2/16/2004
SYSTEM DATA SHEET Coatings ManualChevron Corporation
9.3Reinforced Thick Film Coatings for FDA-Approved Potable Water Immersion Service
3.0 - 4.0 mils
SSPC-SP5 (NACE No. 1) White metal surface.
36.0 mils (min) (sprayable), 80.0 mils (min) (trowelable). (See manufacturers' data sheets for min/max thicknesses per coat)
Use the same manufacturer's paint.
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
Reinforced Thick Film Coatings for Immersion Service
These coatings are normally self-priming; but if a primer is required, use the chosen manufacturer's recommendation.
PRIMER
Roll each coat of spray- or trowelable glass flake to orient the flakes parallel to the substrate. Some systems require a 10-mil wax coat of glass flake-free resin. (See manufacturers' data sheets for wax coat requirements.)
Roll each coat of spray- or trowelable glass flake to orient the flakes parallel to the substrate. Some systems require a 10-mil wax coat of glass flake-free resin. (See manufacturers' data sheets for wax coat requirements.)
If seam sealant or putty is required, use any of the following brands from the Acceptable Brands List: (Vinyl Ester, Rivet and Seam Sealer (Trowel), Polysulfide Flexible Putty). This list is limited to full-service national manufacturers. Local conditions may warrant adding local suppliers.
QRG - 61
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 2/16/2004
SYSTEM DATA SHEET Coatings ManualChevron Corporation
9.4Reinforced Thick Film Coatings for Salt Water and Brine Immersion Service
3.0 - 4.0 mils
SSPC-SP5 (NACE No. 1) White metal surface.
36.0 mils (min) (sprayable), 80.0 mils (min) (trowelable). (See manufacturers' data sheets for min/max thicknesses per coat)
Use the same manufacturer's paint.
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
Reinforced Thick Film Coatings for Immersion Service
These coatings are normally self-priming; but if a primer is required, use the chosen manufacturer's recommendation.
PRIMER
Roll each coat of spray- or trowelable glass flake to orient the flakes parallel to the substrate. Some systems require a 10-mil wax coat of glass flake-free resin. (See manufacturers' data sheets for wax coat requirements.)
Roll each coat of spray- or trowelable glass flake to orient the flakes parallel to the substrate. Some systems require a 10-mil wax coat of glass flake-free resin. (See manufacturers' data sheets for wax coat requirements.)
If seam sealant or putty is required, use any of the following brands from the Acceptable Brands List: (Vinyl Ester, Rivet and Seam Sealer (Trowel), Polysulfide Flexible Putty). This list is limited to full-service national manufacturers. Local conditions may warrant adding local suppliers.
QRG - 62
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 2/16/2004
SYSTEM DATA SHEET Coatings ManualChevron Corporation
9.5Reinforced Thick Film Coatings for Produced Water Immersion Service
3.0 - 4.0 mils
SSPC-SP5 (NACE No. 1) White metal surface.
36.0 mils (min) (sprayable), 80.0 mils (min) (trowelable). (See manufacturers' data sheets for min/max thicknesses per coat)
Use the same manufacturer's paint.
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
Reinforced Thick Film Coatings for Immersion Service
These coatings are normally self-priming; but if a primer is required, use the chosen manufacturer's recommendation.
PRIMER
Roll each coat of spray- or trowelable glass flake to orient the flakes parallel to the substrate. Some systems require a 10-mil wax coat of glass flake-free resin. (See manufacturers' data sheets for wax coat requirements.)
Roll each coat of spray- or trowelable glass flake to orient the flakes parallel to the substrate. Some systems require a 10-mil wax coat of glass flake-free resin. (See manufacturers' data sheets for wax coat requirements.)
If seam sealant or putty is required, use any of the following brands from the Acceptable Brands List: (Vinyl Ester, Rivet and Seam Sealer (Trowel), Polysulfide Flexible Putty). This list is limited to full-service national manufacturers. Local conditions may warrant adding local suppliers.
QRG - 63
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 9/9/2004
SYSTEM DATA SHEET Coatings ManualChevron Corporation
9.6Reinforced Thick Film Coatings for Crude Oil (Sweet or Sour) Immersion Service
3.0 - 4.0 mils
SSPC-SP5 (NACE No. 1) White metal surface.
36.0 mils (min) (sprayable), 80.0 mils (min) (trowelable). (See manufacturers' data sheets for min/max thicknesses per coat)
Use the same manufacturer's paint.
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
Reinforced Thick Film Coatings for Immersion Service
These coatings are normally self-priming; but if a primer is required, use the chosen manufacturer's recommendation.
PRIMER
Roll each coat of spray- or trowelable glass flake to orient the flakes parallel to the substrate. Some systems require a 10-mil wax coat of glass flake-free resin. (See manufacturers' data sheets for wax coat requirements.)
Roll each coat of spray- or trowelable glass flake to orient the flakes parallel to the substrate. Some systems require a 10-mil wax coat of glass flake-free resin. (See manufacturers' data sheets for wax coat requirements.)
If seam sealant or putty is required, use any of the following brands from the Acceptable Brands List: (Vinyl Ester, Rivet and Seam Sealer (Trowel), Polysulfide Flexible Putty). This list is limited to full-service national manufacturers. Local conditions may warrant adding local suppliers.
QRG - 64
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 2/16/2004
SYSTEM DATA SHEET Coatings ManualChevron Corporation
9.7Reinforced Thick Film Coatings for Fuel (Low Aromatic) Immersion Service
3.0 - 4.0 mils
SSPC-SP5 (NACE No. 1) White metal surface.
36.0 mils (min) (sprayable), 80.0 mils (min) (trowelable). (See manufacturers' data sheets for min/max thicknesses per coat)
Use the same manufacturer's paint.
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
Reinforced Thick Film Coatings for Immersion Service
These coatings are normally self-priming; but if a primer is required, use the chosen manufacturer's recommendation.
PRIMER
Roll each coat of spray- or trowelable glass flake to orient the flakes parallel to the substrate. Some systems require a 10-mil wax coat of glass flake-free resin. (See manufacturers' data sheets for wax coat requirements.)
Roll each coat of spray- or trowelable glass flake to orient the flakes parallel to the substrate. Some systems require a 10-mil wax coat of glass flake-free resin. (See manufacturers' data sheets for wax coat requirements.)
If seam sealant or putty is required, use any of the following brands from the Acceptable Brands List: (Vinyl Ester, Rivet and Seam Sealer (Trowel), Polysulfide Flexible Putty). This list is limited to full-service national manufacturers. Local conditions may warrant adding local suppliers.
QRG - 65
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 2/16/2004
SYSTEM DATA SHEET Coatings ManualChevron Corporation
9.8Reinforced Thick Film Coatings for Fuel (High Aromatic) Immersion Service
3.0 - 4.0 mils
SSPC-SP5 (NACE No. 1) White metal surface.
36.0 mils (min) (sprayable), 80.0 mils (min) (trowelable). (See manufacturers' data sheets for min/max thicknesses per coat)
Use the same manufacturer's paint.
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
Reinforced Thick Film Coatings for Immersion Service
These coatings are normally self-priming; but if a primer is required, use the chosen manufacturer's recommendation.
PRIMER
Roll each coat of spray- or trowelable glass flake to orient the flakes parallel to the substrate. Some systems require a 10-mil wax coat of glass flake-free resin. (See manufacturers' data sheets for wax coat requirements.)
Roll each coat of spray- or trowelable glass flake to orient the flakes parallel to the substrate. Some systems require a 10-mil wax coat of glass flake-free resin. (See manufacturers' data sheets for wax coat requirements.)
If seam sealant or putty is required, use any of the following brands from the Acceptable Brands List: (Vinyl Ester, Rivet and Seam Sealer (Trowel), Polysulfide Flexible Putty). This list is limited to full-service national manufacturers. Local conditions may warrant adding local suppliers.
QRG - 66
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 2/16/2004
SYSTEM DATA SHEET Coatings ManualChevron Corporation
9.9Reinforced Thick Film Coatings for Aromatic Hydrocarbon Immersion Service
3.0 - 4.0 mils
SSPC-SP5 (NACE No. 1) White metal surface.
36.0 mils (min) (sprayable), 80.0 mils (min) (trowelable). (See manufacturers' data sheets for min/max thicknesses per coat)
Use the same manufacturer's paint.
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
Reinforced Thick Film Coatings for Immersion Service
These coatings are normally self-priming; but if a primer is required, use the chosen manufacturer's recommendation.
PRIMER
Roll each coat of spray- or trowelable glass flake to orient the flakes parallel to the substrate. Some systems require a 10-mil wax coat of glass flake-free resin. (See manufacturers' data sheets for wax coat requirements.)
Roll each coat of spray- or trowelable glass flake to orient the flakes parallel to the substrate. Some systems require a 10-mil wax coat of glass flake-free resin. (See manufacturers' data sheets for wax coat requirements.)
If seam sealant or putty is required, use any of the following brands from the Acceptable Brands List: (Vinyl Ester, Rivet and Seam Sealer (Trowel), Polysulfide Flexible Putty). This list is limited to full-service national manufacturers. Local conditions may warrant adding local suppliers.
QRG - 67
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 2/16/2004
SYSTEM DATA SHEET Coatings ManualChevron Corporation
10.1Laminate-Reinforced Coatings for Fresh-Water Immersion Service
3.0 - 4.0 mils
SSPC-SP5 (NACE No. 1) White metal surface.
120.0 mils (min)
Use the same manufacturer's paint.
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
Laminate Reinforced Coatings for Immersion Service
These coatings are normally self-priming; but if a primer is required, use the chosen manufacturer's recommendation.
PRIMER
Alternate layers of resin and 1.5 oz glass mat to build 100.0 mils of laminate. Glass-to-resin ratio in the laminate should be 25/75.
If seam sealant or putty is required, use any of the following brands from the Acceptable Brands List: (Vinyl Ester, Rivet and Seam Sealer (Trowel), Polysulfide Flexible Putty). This list is limited to full-service national manufacturers. Local conditions may warrant adding local suppliers.
Sigma Novoguard 7453 is a 2 coat system.
QRG - 68
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 4/9/2003
SYSTEM DATA SHEET Coatings ManualChevron Corporation
10.2Laminate-Reinforced Coatings for Demineralized-Water or Condensate Immersion Service
3.0 - 4.0 mils
SSPC-SP5 (NACE No. 1) White metal surface.
120.0 mils (min)
Use the same manufacturer's paint.
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
Laminate Reinforced Coatings for Immersion Service
These coatings are normally self-priming; but if a primer is required, use the chosen manufacturer's recommendation.
PRIMER
Alternate layers of resin and 1.5 oz glass mat to build 100.0 mils of laminate. Glass-to-resin ratio in the laminate should be 25/75.
If seam sealant or putty is required, use any of the following brands from the Acceptable Brands List: (Vinyl Ester, Rivet and Seam Sealer (Trowel), Polysulfide Flexible Putty). This list is limited to full-service national manufacturers. Local conditions may warrant adding local suppliers.
Sigma Novoguard 7453 is a 2 coat system.
QRG - 69
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 4/9/2003
SYSTEM DATA SHEET Coatings ManualChevron Corporation
10.4Laminate-Reinforced Coatings for Salt Water and Brine Immersion Service
3.0 - 4.0 mils
SSPC-SP5 (NACE No. 1) White metal surface.
120.0 mils (min)
Use the same manufacturer's paint.
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
Laminate Reinforced Coatings for Immersion Service
These coatings are normally self-priming; but if a primer is required, use the chosen manufacturer's recommendation.
PRIMER
Alternate layers of resin and 1.5 oz glass mat to build 100.0 mils of laminate. Glass-to-resin ratio in the laminate should be 25/75.
If seam sealant or putty is required, use any of the following brands from the Acceptable Brands List: (Vinyl Ester, Rivet and Seam Sealer (Trowel), Polysulfide Flexible Putty). This list is limited to full-service national manufacturers. Local conditions may warrant adding local suppliers.
Sigma Novoguard 7453 is a 2 coat system.
QRG - 70
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 4/9/2003
SYSTEM DATA SHEET Coatings ManualChevron Corporation
10.5Laminate-Reinforced Coatings for Produced-Water Immersion Service
3.0 - 4.0 mils
SSPC-SP5 (NACE No. 1) White metal surface.
120.0 mils (min)
Use the same manufacturer's paint.
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
Laminate Reinforced Coatings for Immersion Service
These coatings are normally self-priming; but if a primer is required, use the chosen manufacturer's recommendation.
PRIMER
Alternate layers of resin and 1.5 oz glass mat to build 100.0 mils of laminate. Glass-to-resin ratio in the laminate should be 25/75.
If seam sealant or putty is required, use any of the following brands from the Acceptable Brands List: (Vinyl Ester, Rivet and Seam Sealer (Trowel), Polysulfide Flexible Putty). This list is limited to full-service national manufacturers. Local conditions may warrant adding local suppliers.
Sigma Novoguard 7453 is a 2 coat system.
QRG - 71
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 4/9/2003
SYSTEM DATA SHEET Coatings ManualChevron Corporation
10.6Laminate-Reinforced Coatings for Crude-Oil (Sweet or Sour) Immersion Service
3.0 - 4.0 mils
SSPC-SP5 (NACE No. 1) White metal surface.
120.0 mils (min)
Use the same manufacturer's paint.
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
Laminate Reinforced Coatings for Immersion Service
These coatings are normally self-priming; but if a primer is required, use the chosen manufacturer's recommendation.
PRIMER
Alternate layers of resin and 1.5 oz glass mat to build 100.0 mils of laminate. Glass-to-resin ratio in the laminate should be 25/75.
If seam sealant or putty is required, use any of the following brands from the Acceptable Brands List: (Vinyl Ester, Rivet and Seam Sealer (Trowel), Polysulfide Flexible Putty). This list is limited to full-service national manufacturers. Local conditions may warrant adding local suppliers.
Sigma Novoguard 7453 is a 2 coat system.
QRG - 72
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 4/9/2003
SYSTEM DATA SHEET Coatings ManualChevron Corporation
10.7Laminate-Reinforced Coatings for Fuel (Low Aromatic) Immersion Service
3.0 - 4.0 mils
SSPC-SP5 (NACE No. 1) White metal surface.
120.0 mils (min)
Use the same manufacturer's paint.
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
Laminate Reinforced Coatings for Immersion Service
These coatings are normally self-priming; but if a primer is required, use the chosen manufacturer's recommendation.
PRIMER
Alternate layers of resin and 1.5 oz glass mat to build 100.0 mils of laminate. Glass-to-resin ratio in the laminate should be 25/75.
If seam sealant or putty is required, use any of the following brands from the Acceptable Brands List: (Vinyl Ester, Rivet and Seam Sealer (Trowel), Polysulfide Flexible Putty). This list is limited to full-service national manufacturers. Local conditions may warrant adding local suppliers.
QRG - 73
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 4/9/2003
SYSTEM DATA SHEET Coatings ManualChevron Corporation
10.8Laminate-Reinforced Coatings for Fuel (High Aromatic) Immersion Service
3.0 - 4.0 mils
SSPC-SP5 (NACE No. 1) White metal surface.
120.0 mils (min)
Use the same manufacturer's paint.
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
Laminate Reinforced Coatings for Immersion Service
These coatings are normally self-priming; but if a primer is required, use the chosen manufacturer's recommendation.
PRIMER
Alternate layers of resin and 1.5 oz glass mat to build 100.0 mils of laminate. Glass-to-resin ratio in the laminate should be 25/75.
If seam sealant or putty is required, use any of the following brands from the Acceptable Brands List: (Vinyl Ester, Rivet and Seam Sealer (Trowel), Polysulfide Flexible Putty). This list is limited to full-service national manufacturers. Local conditions may warrant adding local suppliers.
Sigma Novoguard 7453 is a 2 coat system.
QRG - 74
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 4/9/2003
SYSTEM DATA SHEET Coatings ManualChevron Corporation
10.9Laminate-Reinforced Coatings for Aromatic Hydrocarbon Immersion Service
3.0 - 4.0 mils
SSPC-SP5 (NACE No. 1) White metal surface.
120.0 mils (min)
Use the same manufacturer's paint.
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
Laminate Reinforced Coatings for Immersion Service
These coatings are normally self-priming; but if a primer is required, use the chosen manufacturer's recommendation.
PRIMER
Alternate layers of resin and 1.5 oz glass mat to build 100.0 mils of laminate. Glass-to-resin ratio in the laminate should be 25/75.
If seam sealant or putty is required, use any of the following brands from the Acceptable Brands List: (Vinyl Ester, Rivet and Seam Sealer (Trowel), Polysulfide Flexible Putty). This list is limited to full-service national manufacturers. Local conditions may warrant adding local suppliers.
Sigma Novoguard 7453 is a 2 coat system.
QRG - 75
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 4/9/2003
SYSTEM DATA SHEET Coatings ManualChevron Corporation
11.2Demineralized Water or Condensate Coatings Resistant to Temperature Gradients of 50°F & Compatible with Cathodic Protection
2.0 - 3.0 mils
SSPC-SP5 (NACE No. 1) White metal surface.
10.0 mils (min) (see manufacturer's data sheets for min/max thickness per coat)
Use the same manufacturer's paint.
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
High-Temperature/High-Pressure Coating Systems
These coatings are normally self-priming; but if a primer is required, use the chosen manufacturer's recommendation.
PRIMER
Carboline Phenoline 1205 180°F• 255Hempel Coatings (USA), Inc. Hempadur 1550 180°F• 320Sigma Coatings Phenguard Primer 7409 180°F• 300
TEMPERATURE GRADIENT refers to the difference between the stock temperature and the outside temperature of the steel shell. Example: an insulated tank would have 0°F temperature gradient. This list is limited to full-service national manufacturers. Local conditions may warrant adding local suppliers.
Sigma recommends that for temperatures above 140F, the Phenguard system is applied in three 4 mil coats (using Phenguard 7435 as the intermediate coat) rather than two 6mil coats.
QRG - 76
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 3/20/2003
SYSTEM DATA SHEET Coatings ManualChevron Corporation
11.2.1Demineralized Water or Condensate Coatings Resistant to Temperature Gradients of 50°F & Incompatible with Cathodic Protection
2.0 - 3.0 mils
SSPC-SP5 (NACE No. 1) White metal surface.
10.0 mils (min) (see manufacturer's data sheets for min/max thickness per coat)
Use the same manufacturer's paint.
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
High-Temperature/High-Pressure Coating Systems
These coatings are normally self-priming; but if a primer is required, use the chosen manufacturer's recommendation.
PRIMER
Carboline Phenoline 368 WG 180°F• 291Sigma Coatings Phenguard Primer 7409 180°F• 300Ameron Amercoat 91 200°F 410
TEMPERATURE GRADIENT refers to the difference between the stock temperature and the outside temperature of the steel shell. Example: an insulated tank would have 0°F temperature gradient. This list is limited to full-service national manufacturers. Local conditions may warrant adding local suppliers.
The Sigma system (also listed in 11.2) will function with or without cathodic protection.
QRG - 77
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 9/9/2004
SYSTEM DATA SHEET Coatings ManualChevron Corporation
11.4Salt Water & Brine Service Coatings Resistant to Temperature Gradients of 50°F & Compatible with Cathodic Protection
2.0 - 3.0 mils
SSPC-SP5 (NACE No. 1) White metal surface.
10.0 mils (min) (see manufacturer's data sheets for min/max thickness per coat)
Use the same manufacturer's paint.
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
High-Temperature/High-Pressure Coating Systems
These coatings are normally self-priming; but if a primer is required, use the chosen manufacturer's recommendation.
PRIMER
Carboline Phenoline 1205 180°F• 255Hempel Coatings (USA), Inc. Hempadur 1550 180°F• 320Sigma Coatings Phenguard Primer 7409 180°F• 300
TEMPERATURE GRADIENT refers to the difference between the stock temperature and the outside temperature of the steel shell. Example: an insulated tank would have 0°F temperature gradient. This list is limited to full-service national manufacturers. Local conditions may warrant adding local suppliers.
Sigma recommends that for temperatures above 140F, the Phenguard system is applied in three 4 mil coats (using Phenguard 7435 as the intermediate coat) rather than two 6mil coats.
QRG - 78
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 3/20/2003
SYSTEM DATA SHEET Coatings ManualChevron Corporation
11.4.1Salt Water & Brine Service Coatings Resistant to Temperature Gradients of 50°F & Incompatible with Cathodic Protection
2.0 - 3.0 mils
SSPC-SP5 (NACE No. 1) White metal surface.
10.0 mils (min) (see manufacturer's data sheets for min/max thickness per coat)
Use the same manufacturer's paint.
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
High-Temperature/High-Pressure Coating Systems
These coatings are normally self-priming; but if a primer is required, use the chosen manufacturer's recommendation.
PRIMER
Carboline Phenoline 368 WG 180°F• 291Sigma Coatings Phenguard Primer 7409 180°F• 300Ameron Amercoat 91 200°F 410
TEMPERATURE GRADIENT refers to the difference between the stock temperature and the outside temperature of the steel shell. Example: an insulated tank would have 0°F temperature gradient. This list is limited to full-service national manufacturers. Local conditions may warrant adding local suppliers.
The Sigma system (also listed in 11.4) will function with or without cathodic protection.
QRG - 79
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 9/9/2004
SYSTEM DATA SHEET Coatings ManualChevron Corporation
11.4.2Salt Water & Brine High Temperature/High Pressure Service* Coatings Resistant to Temperatures to 180°F, Pressures of 1000 PSI & Incompatible with Cathodic Protection
2.0 - 3.0 mils
SSPC-SP5 (NACE No. 1) White metal surface.
10.0 mils (min) (see manufacturer's data sheets for min/max thickness per coat)
Use the same manufacturer's paint.
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
High-Temperature/High-Pressure Coating Systems
These coatings are normally self-priming; but if a primer is required, use the chosen manufacturer's recommendation.
PRIMER
Carboline Phenoline 368 WG 180°F• 291Ameron Amercoat 91 200°F 410Sigma Coatings Phenguard Primer 7409 212°F• 300
* As in high-pressure separators. This list is limited to full-service national manufacturers. Local conditions may warrant adding local suppliers.
The Sigma system (also listed in 11.4) will function with or without cathodic protection.
Sigma recommends that for temperatures above 140F, the Phenguard system is applied in three 4 mil coats (using Phenguard 7435 as the intermediate coat) rather than two 6mil coats.
QRG - 80
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 9/9/2004
SYSTEM DATA SHEET Coatings ManualChevron Corporation
11.5Produced Water Service Coatings Resistant to Temperature Gradients of 50°F & Compatible with Cathodic Protection
2.0 - 3.0 mils
SSPC-SP5 (NACE No. 1) White metal surface.
10.0 mils (min) (see manufacturer's data sheets for min/max thickness per coat)
Use the same manufacturer's paint.
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
High-Temperature/High-Pressure Coating Systems
These coatings are normally self-priming; but if a primer is required, use the chosen manufacturer's recommendation.
PRIMER
Carboline Phenoline 1205 180°F• 255Hempel Coatings (USA), Inc. Hempadur 1550 180°F• 320Sigma Coatings Phenguard Primer 7409 180°F• 300
TEMPERATURE GRADIENT refers to the difference between the stock temperature and the outside temperature of the steel shell. Example: an insulated tank would have 0°F temperature gradient. This list is limited to full-service national manufacturers. Local conditions may warrant adding local suppliers.
Sigma recommends that for temperatures above 140F, the Phenguard system is applied in three 4 mil coats (using Phenguard 7435 as the intermediate coat) rather than two 6mil coats.
QRG - 81
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 3/20/2003
SYSTEM DATA SHEET Coatings ManualChevron Corporation
11.5.1Produced Water Service Coatings Resistant to Temperature Gradients of 50°F & Incompatible with Cathodic Protection
2.0 - 3.0 mils
SSPC-SP5 (NACE No. 1) White metal surface.
10.0 mils (min) (see manufacturer's data sheets for min/max thickness per coat)
Use the same manufacturer's paint.
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
High-Temperature/High-Pressure Coating Systems
These coatings are normally self-priming; but if a primer is required, use the chosen manufacturer's recommendation.
PRIMER
Carboline Phenoline 368 WG 180°F• 291Sigma Coatings Phenguard Primer 7409 180°F• 300Ameron Amercoat 91 200°F 410
TEMPERATURE GRADIENT refers to the difference between the stock temperature and the outside temperature of the steel shell. Example: an insulated tank would have 0°F temperature gradient. This list is limited to full-service national manufacturers. Local conditions may warrant adding local suppliers.
The Sigma system (also listed in 11.5) will function with or without cathodic protection.
QRG - 82
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 9/9/2004
SYSTEM DATA SHEET Coatings ManualChevron Corporation
11.5.2Produced Water High Temperature/High Pressure Service Coatings* Resistant to Temperatures to 180°F, Pressures of 1000 PSI & Incompatible with Cathodic Protection
2.0 - 3.0 mils
SSPC-SP5 (NACE No. 1) White metal surface.
10.0 mils (min) (see manufacturer's data sheets for min/max thickness per coat)
Use the same manufacturer's paint.
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
High-Temperature/High-Pressure Coating Systems
These coatings are normally self-priming; but if a primer is required, use the chosen manufacturer's recommendation.
PRIMER
Carboline Phenoline 368 WG 180°F• 291Sigma Coatings Phenguard Primer 7409 180°F• 300Ameron Amercoat 91 200°F 410
* As in high-pressure separators. This list is limited to full-service national manufacturers. Local conditions may warrant adding local suppliers.
The Sigma system (also listed in 11.5) will function with or without cathodic protection.
QRG - 83
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 9/9/2004
SYSTEM DATA SHEET Coatings ManualChevron Corporation
11.6Crude Oil Service (Sweet or Sour) Coatings Resistant to Temperature Gradients of 50°F & Compatible with Cathodic Protection
2.0 - 3.0 mils
SSPC-SP5 (NACE No. 1) White metal surface.
10.0 mils (min) (see manufacturer's data sheets for min/max thickness per coat)
Use the same manufacturer's paint.
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
High-Temperature/High-Pressure Coating Systems
These coatings are normally self-priming; but if a primer is required, use the chosen manufacturer's recommendation.
PRIMER
Carboline Phenoline 1205 180°F• 255Hempel Coatings (USA), Inc. Hempadur 1550 180°F• 320Sigma Coatings Phenguard Primer 7409 180°F• 300
TEMPERATURE GRADIENT refers to the difference between the stock temperature and the outside temperature of the steel shell. Example: an insulated tank would have 0°F temperature gradient. This list is limited to full-service national manufacturers. Local conditions may warrant adding local suppliers.
Sigma recommends that for temperatures above 140F, the Phenguard system is applied in three 4 mil coats (using Phenguard 7435 as the intermediate coat) rather than two 6mil coats.
QRG - 84
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 5/2/2003
SYSTEM DATA SHEET Coatings ManualChevron Corporation
11.6.1Crude Oil Service (Sweet or Sour) Coatings Resistant to Temperature Gradients of 50°F & Incompatible with Cathodic Protection
2.0 - 3.0 mils
SSPC-SP5 (NACE No. 1) White metal surface.
10.0 mils (min) (see manufacturer's data sheets for min/max thickness per coat)
Use the same manufacturer's paint.
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
High-Temperature/High-Pressure Coating Systems
These coatings are normally self-priming; but if a primer is required, use the chosen manufacturer's recommendation.
PRIMER
Carboline Phenoline 368 WG 180°F• 291Sigma Coatings Phenguard Primer 7409 180°F• 300Ameron Amercoat 91 200°F 410
TEMPERATURE GRADIENT refers to the difference between the stock temperature and the outside temperature of the steel shell. Example: an insulated tank would have 0°F temperature gradient. This list is limited to full-service national manufacturers. Local conditions may warrant adding local suppliers.
The Sigma system (also listed in 11.6) will function with or without cathodic protection.
Sigma recommends that for temperatures above 140F, the Phenguard system is applied in three 4 mil coats (using Phenguard 7435 as the intermediate coat) rather than two 6mil coats.
QRG - 85
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 9/9/2004
SYSTEM DATA SHEET Coatings ManualChevron Corporation
11.6.2Crude Oil (Sweet or Sour) High Temperature/High Pressure Service Coatings* Resistant to Temperatures to 180°F, Pressures of 1000 PSI & Incompatible with
2.0 - 3.0 mils
SSPC-SP5 (NACE No. 1) White metal surface.
10.0 mils (min) (see manufacturer's data sheets for min/max thickness per coat)
Use the same manufacturer's paint.
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
High-Temperature/High-Pressure Coating Systems
These coatings are normally self-priming; but if a primer is required, use the chosen manufacturer's recommendation.
PRIMER
Carboline Phenoline 368 WG 180°F• 291Sigma Coatings Phenguard Primer 7409 180°F• 300Ameron Amercoat 91 200°F 410
* As in high-pressure separators. This list is limited to full-service national manufacturers. Local conditions may warrant adding local suppliers.
The Sigma system (also listed in 11.6) will function with or without cathodic protection.
Sigma recommends that for temperatures above 140F, the Phenguard system is applied in three 4 mil coats (using Phenguard 7435 as the intermediate coat) rather than two 6mil coats.
QRG - 86
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 9/9/2004
SYSTEM DATA SHEET Coatings ManualChevron Corporation
12.1Under Insulation & Fireproofing - Non-Reinforced Thin Film Epoxy Coatings for Continuous or Cyclic Carbon Steel Temperatures -50°F to 450°F
2.0 - 3.0 mils
SSPC-SP10 (NACE No. 2) Near-white blast finish.
10.0 mils (min)
Use material from manufacturer.
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
Coatings under Insulation & Fireproofing
These coatings contain epoxy and epoxy phenolic resins.
Hempel Coatings (USA), Inc. Hempadur 1554 • 325Sigma Coatings Phenguard Primer 7409 250°F• 300Sigma Coatings Sigmacover CM Miocoat II 7427US 250°F• 324Sherwin Williams Epo-Phen B62A55/B62V55 300°F• 264International Intertherm 228 392°F• 326Ameron Amercoat 90HS w/880 Additive 400°F• 323Devoe HT-403 400°F• 217PPG Industries 97-946 400°F• 262Carboline Thermoline 450 425°F• 255Dampney Company, Inc. Thurmalox 215 450°F• 274
PRIMEREpoxy - Phenolic
Nonreinforced Thin Film
5.0 - 7.0 mils DFT
These coatings contain epoxy and epoxy phenolic resins.
Sigma recommends CM Miocoat II at lower temperatures due to it's increased flexibility.
QRG - 87
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 9/9/2004
SYSTEM DATA SHEET Coatings ManualChevron Corporation
12.4Under Insulation & Fireproofing - Non-Reinforced Thin Film Epoxy Coatings for Continuous or Cyclic Stainless Steel Temperatures -50°F to 450°F
1.0 - 2.0 mils
SSPC-SP7 (NACE No. 4) Solvent wipe and brush blast.
10.0 mils (min)
Use material from manufacturer.
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
Coatings under Insulation & Fireproofing
These coatings contain epoxy and epoxy phenolic resins.
Hempel Coatings (USA), Inc. Hempadur 1530 417Sigma Coatings Sigmacover CM Miocoat II 7427US 250°F• 324Sherwin Williams Epo-Phen B62A55/B62V55 300°F• 264International Intertherm 228 392°F• 326Ameron Amercoat 90HS w/880 Additive 400°F• 323Devoe HT-403 400°F• 217PPG Industries 97-946 400°F• 262Carboline Thermoline 450 425°F• 255Dampney Company, Inc. Thurmalox 215 450°F• 274
PRIMEREpoxy - Phenolic
Nonreinforced Thin Film
5.0 - 7.0 mils DFT
These coatings contain epoxy and epoxy phenolic resins.
Hempel Coatings (USA), Inc. Hempadur 1530 417Sigma Coatings Sigmacover CM Miocoat II 7427US 250°F• 324Sherwin Williams Epo-Phen B62A55/B62V55 300°F• 264International Intertherm 228 392°F• 326Ameron Amercoat 90HS w/880 Additive 400°F• 323Devoe HT-403 400°F• 217PPG Industries 97-946 400°F• 262Carboline Thermoline 450 425°F• 255Dampney Company, Inc. Thurmalox 216 450°F• 321
TOPCOATEpoxy - Phenolic
Nonreinforced Thin Film
5.0 - 7.0 mils DFT
Sigma recommends CM Miocoat II at lower temperatures due to it's increased flexibility.
QRG - 88
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 9/9/2004
SYSTEM DATA SHEET Coatings ManualChevron Corporation
12.7Under Insulation & Fireproofing - Non-Reinforced Thin Film Inorganic Coatings for Carbon Steel or Stainless Steel Temperatures Above 450°F
1.0 - 2.0 mils
Stainless Steel: SSPC-SP7 (NACE No. 4) Solvent wipe and brush blast. Carbon Steel: SSPC-SP10 (Nace #2) Near-white metal blast
10.0 mils (min)
Use material from manufacturer.
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:
Surface Prep:
Total DFT:
Touch Up:
Coatings under Insulation & Fireproofing
Ameron 738 is not suitable for services that have frequent thermal cycles. Cracking of the coating in this service has been documented.
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 5/2/2003
SYSTEM DATA SHEET Coatings ManualChevron Corporation
20.1Epoxy Coatings for Concrete: Service Temperatures <140°F, Moderate Physical Abuse, Intermittent & Continuous Exposure
Not applicable
Follow manufacturer's recommendation.
Varies with manufacturer.
Manufacturer's Recommendation
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
This coating system is NOT a substitute for a coating manufacturer's recommendation. REINFORCING: Continuous Exposure (Use a flake- or textile-reinforced system to resist physical abuse. Review the resin selection (probably polyester, epoxy, or modified urethane) with the coating manufacturer to ensure it is resistant to the corrosive media.); Intermittent Exposure (Use a thin film or elastomeric system. Review the resin selection (probably epoxy or modified urethane resin) with the coating manufacturer to ensure it is resistant to the corrosive media.); General (Ask the coating manufacturer to recommend reinforcing material (aggregate, mortar topping, chopped glass, or glass mat) not only to withstand moderate physical abuse, but also, where necessary, to reduce the probability of cracks developing in the coating and allowing product to leak.) In some cases, additional coats of material may be necessary to prepare the concrete surface for the coating system.
QRG - 90
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 9/9/2004
SYSTEM DATA SHEET Coatings ManualChevron Corporation
20.2Epoxy Coatings for Concrete: Service Temperatures <140°F, Mild Physical Abuse, Intermittent & Continuous Exposure
Not applicable
Follow manufacturer's recommendation.
Varies with manufacturer.
Manufacturer's Recommendation
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
This coating system is NOT a substitute for a coating manufacturer's recommendation. REINFORCING: Continuous Exposure (Use a flake- or textile-reinforced system to resist physical abuse and for immersion service. Review the resin selection (probably polyester, epoxy, or modified urethane) with the coating manufacturer to ensure it is resistant to the corrosive media.); Intermittent Exposure (Use a thin film or elastomeric system. Review the resin selection (probably epoxy or modified urethane resin) with the coating manufacturer to ensure it is resistant to the corrosive media.); General (Ask the coating manufacturer to recommend reinforcing material (aggregate, mortar topping, chopped glass, or glass mat) not only to withstand moderate physical abuse, but also, where necessary, to reduce the probability of cracks developing in the coating and allowing product to leak. Whenever a concrete containment structure cracks, it moves slightly, creating localized stresses in the coating that often causes cracks.) In some cases, additional coats of material may be necessary to prepare the concrete surface for the coating system.
QRG - 91
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 9/9/2004
SYSTEM DATA SHEET Coatings ManualChevron Corporation
20.3Epoxy Coatings for Concrete: Service Temperatures <140°F, Aggressive Physical Abuse, Intermittent & Continuous Exposure
Not applicable
Follow manufacturer's recommendation.
Varies with manufacturer.
Manufacturer's Recommendation
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
This coating system is NOT a substitute for a coating manufacturer's recommendation. REINFORCING: Continuous Exposure (Use a laminate - or textile-reinforced system to resist physical abuse and for immersion service. Review the resin selection (probably polyester, epoxy, or modified urethane) with the coating manufacturer to ensure it is resistant to the corrosive media.); Intermittent Exposure (Use a laminate- or textile-reinforced system. Review the resin selection (probably polyester, epoxy, or modified urethane resin) with the coating manufacturer to ensure it is resistant to the corrosive media. Depending on the type of physical abuse, a flake-reinforced system might be used on the advice of a coating specialist or manufacturer.); General (Ask the coating manufacturer to recommend reinforcing material (aggregate, mortar topping, chopped glass, or glass mat) not only to withstand moderate physical abuse, but also, where necessary, to reduce the probability of cracks developing in the coating and allowing product to leak. Whenever a concrete containment structure cracks, it moves slightly, creating localized stresses in the coating that often cause cracks.) In some cases, additional coats of material may be necessary to prepare the concrete surface for the coating system.
QRG - 92
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 9/9/2004
SYSTEM DATA SHEET Coatings ManualChevron Corporation
13.1Rivet and Seam Sealer - Epoxy (Spray)
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 2/16/2004
SYSTEM DATA SHEET Coatings ManualChevron Corporation
13.2Rivet and Seam Sealer - Epoxy (Trowel)
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 2/16/2004
SYSTEM DATA SHEET Coatings ManualChevron Corporation
13.3Rivet and Seam Sealer - Isophthalic Polyester
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:Surface Prep:
Total DFT:
Touch Up:
Seam Sealers & Putties
Sherwin Williams 920-W-979 • 2Sherwin Williams 970-B-703 • 40
Polyester - Isophthalic
Rivet and Seam Sealer (Spray)
QRG - 95
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 2/16/2004
SYSTEM DATA SHEET Coatings ManualChevron Corporation
13.4Rivet and Seam Sealer - Vinyl Ester
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
Anchor Pattern:Surface Prep:
Total DFT:
Touch Up:
Seam Sealers & Putties
International Interline 33SF • 0Sherwin Williams Magnaplate VE Laminate 939X465/531-0-0 • 40
Vinyl Ester
Rivet and Seam Sealer (Trowel)
QRG - 96
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 2/16/2004
SYSTEM DATA SHEET Coatings ManualChevron Corporation
13.5Polysulfide Flexible Putty
Coat, Generic Classification, DFT
By Max Svc TempVOC (G/L)Product DesignationManufacturer
• VOC at or below 340 g/l is the anticipated regulatory limit. Check local standards for current VOC limits.Consult manufacturer's product data sheets for specific details about applying any coating.
May 1998Last Update: 2/16/2004
Manufacturer Product Coating Systems
Coatings Manual Chevron Corporation
Acceptable Brands: By Generic Classification and SubclassificationVOC(G/L)
Alkyd - Inhibited
Ameron Amercoat 5105 336 1.1 2.1 2.2
Carboline Carbocoat 115SG 408 1.1 2.1 2.2
Devoe Devguard 4160 419 1.1 2.1 2.2
Hempel Coatings (USA), Inc.
Hempalin Primer 1205 415 1.1
Hempel Coatings (USA), Inc.
Hempalin Primer 1218 330 1.1 2.1 2.2
International Interlac 260 300 1.1 2.1 2.2
International Interprime 198 509
International Interprime 198 509 2.1 2.2
Jotun Paints Cromoprimer 400 1.1 2.1 2.2
PPG Industries 7-852 Series Industrial Primers 376 2.1 2.2
Sherwin Williams Hi-Solids Alkyd Metal Primer B50NZ2
308 1.1 2.1 2.2
Sigma Coatings Sigmarine Multiprimer 7117 390
Sigma Coatings Sigmarine Primer ZP 7135 372 1.1 2.1 2.2
Southern Coatings 94-258 Series 336 1.1
Tnemec Company Azeron Primer FD88 330
Tnemec Company Azeron Primer FD88 330 2.1 2.2
Tnemec Company Versare Primer 4 342
Tnemec Company Versare Primer 4 342 2.1 2.2
Alkyd Enamel
Ameron Amercoat 220 180 2.1
Ameron Amercoat 5405 327 2.1 2.2 2.8 2.9
Carboline Carbocoat 139 240 2.1 2.2 2.8 2.9
Devoe Devguard 4308 428
Devoe Devguard 4308 428 2.1 2.2 2.8 2.9
Devoe Devguard 4348 340
Devoe Devguard 4348 340 2.1 2.2 2.8
Hempel Coatings (USA), Inc.
Hempalin Enamel 5214 410 2.1 2.2 2.8 2.9
International Interlac 665 427 2.1 2.2 2.8 2.9
Jotun Paints Pilot II 418 2.1 2.2 2.8 2.9
PPG Industries 7-282 336 2.1 2.2 2.8 2.9
Sherwin Williams Industrial Enamel B54Z Series 417 2.1 2.2 2.8 2.9
Sherwin Williams Industrial Enamel VOC B54-Z Series