June 7, 2022 1 WATER CHEMISTRY IN POWER PLANT BY P. SRIVASTAVA SR. MANAGER(CHEM.)
25
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Chemistry in Power Plant

April 18, 20231

WATER CHEMISTRY IN POWER PLANT

BY

P. SRIVASTAVA

SR. MANAGER(CHEM.)

Page 2: Chemistry in Power Plant

April 18, 20232

WATER CHEMISTRY IN POWER PLANT

WATER CHEMISTRY IS A VERY IMPORTANT DISCIPLINE IN POWER SECTOR.

TO ACHIEVE HIGHER OPERATION EFFICIENCY AND TO REDUCE PLANT DOWNTIME, HIGH WATER QUALITY STANDARDS ARE TO BE MAINTAINED

Page 3: Chemistry in Power Plant

April 18, 20233

WATER CHEMISTRY IN POWER PLANT

PRODUCTION OF : - --- D.M. WATER FOR BOILER MAKE-UP. --- FILTER WATER FOR SOFTENING PLANT, D.M. PLANT, DRINKING WATER AND A.C. COOLING SYSTEM. MONITORING OF STEAM/ WATER PARAMETERS H.P./L.P. DOSING. TESTING OF COAL. TESTING OF LUB OIL.

Page 4: Chemistry in Power Plant

April 18, 20234

WATER CHEMISTRY IN POWER PLANT

CIRCULATING WATER TREATMENT POLLUTION MONITORING

– STACK MONITORING– AMBIENT AIR– WATER EFFLUENT

EFFLUENT TREATMENT PLANT COMMISSIONING ACTIVITES

Page 5: Chemistry in Power Plant

April 18, 20235

WATER FLOW DIAGRAM

CLARIFLOCCULATOR

GRAVITY FILTER

D.M. PLANT

SOFTENING PLANT

COOLING WATER

U/G STORAGE TANK

RAW WATER

DRINKING WATER

BOILER MAKEUP

C.W. MAKEUP

Page 6: Chemistry in Power Plant

April 18, 20236

D.M. PLANT

WEAKACIDCATION

STRONG ACID CATION

ACF

WEAKBASE ANION

STRONGBASE ANION

MIXED BED

DEGASSER

D.M. WATERSTORAGETANK

Page 7: Chemistry in Power Plant

April 18, 20237

D.M. WATER QUALITY

pH - 7.0 ± 0.2 CONDUCTIVITY < 0.1 mho TDS - NIL SiO2 < 20 ppb

Page 8: Chemistry in Power Plant

April 18, 20238

WATER STEAM CYCLE (GAS PROJECT)

D.M. WATER RFT CONDENSER D/A

LP TURBINE LP STEAM LP BOILER

HP TURBINE HP STEAM HP BOILER

L.P. DOSING

H.P. DOSING

HP BFP

LP BFP

Page 9: Chemistry in Power Plant

April 18, 20239

WATER STEAM CYCLE (THERMAL PROJECT)

D.M. WATER CST CONDENSER D/A

TURBINE STEAM BOILER

T.S.P. DOSING

HYDRAZINE DOSING

BFP

AMMONIA DOSING

CEP

Page 10: Chemistry in Power Plant

April 18, 202310

WATER/STEAM CHEMISTRY

PARAMETERS MONITORED– pH– Silica– Conductivity– After Cation Conductivity– Dissolved Oxygen– Sodium– Copper– Iron

Page 11: Chemistry in Power Plant

April 18, 202311

WATER QUALITY

FEED WATER– ACC <0.2 uS/cm– pH 8.8-9.2– Total Iron+Copper <0.02 ppm– Silica <0.02 ppm– Dissolved Oxygen <7 ppb

Page 12: Chemistry in Power Plant

April 18, 202312

WATER QUALITY

CONDENSATE WATER– ACC <0.2 uS/cm

– pH 8.8-9.2

– Silica <0.02 ppm

– Dissolved Oxygen <40 ppb

Page 13: Chemistry in Power Plant

April 18, 202313

WATER QUALITY

BOILER WATER– Conductivity <30 uS/cm

– pH 9.2-9.6

– Silica <0.300 ppm

– Phosphate 2-4 ppm

Page 14: Chemistry in Power Plant

April 18, 202314

WATER QUALITY

STEAM– ACC <0.2 uS/cm– pH 8.8-9.2– Total Iron+Copper <0.02 ppm– Silica <0.02 ppm– Sodium <10 ppb

Page 15: Chemistry in Power Plant

April 18, 202315

DISTRIBUTION RATIO BETWEEN STEAM & BOILER WATER AT pH 9.5

Drum Pressure Silica in Boiler Water 194 Kg/Cm2 130 ppb

176 Kg/Cm2 220 ppb159 Kg/Cm2 290 ppb 134 Kg/Cm2 500 ppb117 Kg/Cm2 1000 ppb100 Kg/Cm2 2220 ppb 65 Kg/Cm2 4000 ppb -- Boiller Drum Pressure is to be maintined as such,Silica value in Main Steam maintain bellow 20 ppb.

Page 16: Chemistry in Power Plant

April 18, 202316

100

10-1

10-2

10-3

10-4

10-5

10-6

10-7

226 220 200 180 160 140 120 100 50 40 30

PRESSURE ( BAR)

PA

RT

ITIO

N C

OE

FF

ICIE

NT

K

p

SiO2

NaOH

NaCl

PARTITION COEFFICIENT AT DIFFERENT PRESSURES

Page 17: Chemistry in Power Plant

April 18, 202317

SOURCES OF IMPURITIES IN STEAM

By evaporation from the boiler drum By entrainment of boiler water droplets in

saturated steam. As impurity present in feed water used in de-

super heater spray.

Page 18: Chemistry in Power Plant

April 18, 202318

EFFECTS OF SILICA

Silica has high partition coefficient, so it has tendency to deposit from steam onto turbine.

Silica can deposit on turbine blades specially on LP turbine, which can lead to significant loss of output.

Page 19: Chemistry in Power Plant

April 18, 202319

H.P. DOSING

COORDINATED PHOSPHATE CONTROL

Na3PO4+H2O Na2HPO4 + NaOH

Na2HPO4+H2O NaH2PO4 + NaOH

NaOH + HCl (As Impurity) NaCl + H2O

Page 20: Chemistry in Power Plant

April 18, 202320

L.P.DOSING

AMMONIA & HYDRAZINE HYDRATE DOSING

AMMONIA IS USED TO INCREASE THE pH OF THE SYSTEM AND HYDRAZINE IS USED TO REMOVE THE OXYGEN

N2H4 + O2 N2 + H2O

3N2H4 4NH3 + N2

Page 21: Chemistry in Power Plant

April 18, 202321

CHEMICAL CONTROL OF GENERATOR STATOR WATER COOLING CIRCUITS

GENERATOR STATOR COOLANT --- D.M. WATERSTATOR WATER PARAMETER TO BE MAINTAINED - pH 6.8 + .2 - K < 1.0 µs/cm - Copper < 50 PPb - D.O. < 10 PPb in low D.O. regime

2.0 to 5.0 PPM in high D.O. regime

Page 22: Chemistry in Power Plant

April 18, 202322

CORROSION OF COPPER

There are two methods where the copper is best passivated and minimum corrosion is found.

1. Low dissolved oxygen regime.

2. High dissolved oxygen regime.

Page 23: Chemistry in Power Plant

April 18, 202323

LOW D.O. REGIME

- Limits below 10 PPb

With low D.O. concentration, copper corrosion is inhibited by a passive film of Cuprous Oxide(Cu2O).

Page 24: Chemistry in Power Plant

April 18, 202324

HIGH D.O. REGIME

- Limits 2 to 5 PPM

With high D.O. concentration, copper corrosion is inhibited by a passive film of Cupric Oxide(CuO).

Page 25: Chemistry in Power Plant

April 18, 202325